Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
JOHN CRANE
Central Projects Group
GB
Instruction Manual
Reference No.: GA-140734-IOM
Mechanical Seal
Type 8BER
Seal Type 8BER
John Crane Assembly Code 0800/8BER//GA-140734
John Crane Drawing No. GA-140734
Manual Reference number (IM) GA-140734-IOM
Global Part Number 89490242
End user BRASKEM IDESA SAPI
Contractor ETILENO XXI Services B.V.
OEM FLOWSERVE
Customer PO Number 2408A0108
Plant Owner/Site/Unit COATZACOALCOS ETHYLENE DERIVATIVES
Plant Item Number 20-P-2604 A/B
Service Name C3-C4 HYDROGENATION RECYCLE PUMPS
(API 682 or ISO 21049 & cat 3 seals ONLY)
Maximum Surface Temperature, zones 130 °C < T3
1,2,21 and 22 (ATEX, 94/9/EC)
This seal may only be installed, commissioned and maintained by an authorised plant machinery
specialist, paying close attention to these instructions and all other relevant regulations. Failure to do
this relieves the manufacturer from any liability or warranties.
In the interest of continuous development, John Crane reserves the right to alter designs and
specifications without prior notice.
For your nearest John Crane facility, please contact one of the locations below
Contents
1 General.......................................................................................................3
1.1 Introduction .................................................................................................3
1.2 Range of Application ...................................................................................3
2 Safety & Environment ...............................................................................3
2.1 Symbols ......................................................................................................3
2.2 Safety Instructions .......................................................................................3
2.3 Environmental Aspects................................................................................4
2.3.1 Company policy extract ..................................................................4
2.3.2 Recycling ........................................................................................4
3 Transportation and Storage .....................................................................5
4 Description of the Mechanical Seal .........................................................5
4.1 Construction ................................................................................................5
4.2 Function ......................................................................................................6
4.3 Operating Conditions...................................................................................6
5 Installation and Removal ..........................................................................6
5.1 Preparation for Fitting ..................................................................................6
5.2 Installation Tolerances ................................................................................7
5.2.1 Shape and Positional Tolerances ...................................................7
5.2.2 Surface Finish.................................................................................7
5.3 Installation ...................................................................................................7
5.3.1 Tightening Torques .........................................................................9
5.3.2 Lubricants .....................................................................................10
5.4 Seal Removal ............................................................................................10
5.5 Installation and Removal of Shrink Discs (John Crane supply*) ................10
6 Commissioning and Decommissioning.................................................11
7 Maintenance/Repair ................................................................................14
7.1 Maintenance .............................................................................................14
7.2 Reconditioning ..........................................................................................15
7.3 Spare Parts ...............................................................................................16
8 Malfunction, Causes and Correction .....................................................16
9 Accompanying Documents ....................................................................16
Instruction Manual Page: 3
of: 16
Type 8BER Edition 7.6
1 General
Danger
1.1 Introduction
Mandatory instructions
This Instruction Manual is provided to designed to prevent personal
familiarise the user with the seal arrangement injury or extensive damage.
and its use. The Instructions must be read
and applied whenever work is done on the ATTENTION Special instructions or
seal, and must be available to the operating information to avoid damage
and maintenance personnel. to the seal or its surroundings.
These instructions will help to avoid danger
and increase reliability. Note: Information for easy
installation and efficient
John Crane reserve the right to change the operation.
seal and specifications described in this
manual where it is necessary for technical Environmental Note
development and without prior notice. The
latest issue supersedes all previous versions.
The safety notes refer to the arrangement In order to avoid unforeseen hazards do not make
unauthorised changes to the fluid to be sealed,
supplied. They must be used in conjunction
the specified duty, or the seal parts.
with the relevant safety regulations for the
machine, auxiliary equipment, plant and
sealed fluid.
2.1 Symbols
The following symbols are used in this
Instruction Manual to highlight information of
particular importance:
Instruction Manual Page: 4
of: 16
Type 8BER Edition 7.6
Fig. 2: Typical Metal Bellows Mechanical Seal The seal cartridge has been selected
to safely contain the maximum static
Primary seal components seal chamber pressure. Any change
a) primary ring from the original, specified pump
b) mating ring operating conditions, including casing
and/or piping hydrotest may
Secondary seal component
compromise this safe containment.
c) static seal Refer to the Seal Data Sheet specific
d) static seal to the plant item or consult John
Crane for the maximum sealing-
Spring component pressure rating of the seal cartridge.
e) metals bellows
Drive and retaining components
f) compression collar 5 Installation and Removal
5.1 Preparation for Fitting
4.2 Function Check whether the seal is complete, clean
The hydraulic pressure and the spring force and undamaged.
press the axially flexible primary ring against
the stationary mating ring. Wear at the Clean all machinery abutments, sealing
primary seal is minimised by a very thin and fitting surfaces (use only absorbent
lubricating film. Lubrication is provided by the and fluff-free polishing cloth for cleaning).
sealed fluid; in the case of gas, the Remove any protective coatings.
mechanism is usually enhanced by spiral
grooves in order that the faces run non- Check all relevant machinery dimensions,
contacting. Some liquid seals use macro and that correct chamfers (see fig. 3) exist
features on the face to enhance lubrication on all leading edges. Refer to drawing in
such as shallow slots and grooves (spiral Section 9.
grooves in the case of Upstream Pumping).
With very low contact loads special seals can 1,5 mm
Removal
Remove rust, which may have formed on
the shaft in front of the sleeve.
Instruction Manual Page: 11
of: 16
Type 8BER Edition 7.6
If the outer and inner rings have not If the seal is unidirectional, check that the
separated, remove some screws and seal s rotation direction matches the
insert them in the neighbouring extraction machine s rotation direction.
screw threads.
With liquid lubricated seals avoid dry
The shrink disc may have to be cleaned running under any circumstances, as
and re-greased before re-assembly (use a it will damage the seal and may result
grease containing MoS2 on the shrink disc in a hazard. (Not relevant to gas
cones and locking screws). lubricated seals and dry containment
seals).
6 Commissioning and Ensure that if a bearing is
Decommissioning ATTENTION fitted as part of the seal
assembly the Instructions on
Note before start-up: the Installation drawing (see
If the seal cartridge requires auxiliary Section 9 and front page) are
systems for its reliable operation refer to applied. Bearings must not be
the separate Instruction Manuals for run without lubricant.
advice on the installation, operation,
function/alarm setting and maintenance of It is advisable to pressurise
the system or systems. ATTENTION the machine and check for
static leaks before starting it
Ensure transit plugs are removed and dynamically.
seal drain connections are correctly piped
or open. For hot duties (above 150°C)
Ensure all connections are either correctly ATTENTION ensure pump has been
piped or safely plugged with a metal plug. brought up to operating
temperature prior to start-up.
Ensure valves controlling circulation, Rapid axial differential
flush, quench and buffer or barrier topping thermal growth between shaft
up systems are correctly positioned. and pump casing could result
Check, where appropriate, flow rates for in seal malfunction.
Plans 32, 54, 62, and 72 are at the
required values. If a Piping Plan 52, 75 or 76 is
If a heat exchanger is included in the ATTENTION connected to a flare header
support system and isolating valves ensure the connection is kept
are used in the coolant supply, a isolated until the pump is
pressure relief valve should be primed.
incorporated between the isolating
valves. If a water test has been
ATTENTION applied when flexible graphite
Ensure the seal chamber and/or barrier, seat/mating ring seals are
buffer and cooling circuits are fully used, they must be renewed
vented. (Not necessary on gas lubricated or thoroughly dried before use
seals). This is particularly important on on a hydrocarbon service
Upstream Pumping designs if a localised above 100 oC
closed-loop system is used; it is
recommended the machine shaft is spun
for a short time and static venting
Check the correct setting and
repeated to ensure all gas is removed
operation of electrical warning
from the circuit.
systems associated with seal
operation.
Instruction Manual Page: 12
of: 16
Type 8BER Edition 7.6
9 Accompanying Documents
Seal Installation Drawing. See front sheet
for specific drawing reference number.
Seal Data Sheet (if applicable)
John Crane
Engineered Sealing Systems
GB
Manual de instrucciones
Cierre Mecánico
Tipo 8BER
John Crane Código 0800/8BER//GA-140734
John Crane , nº Plano GA-140734
Número pieza Global ( GPN ) 89490242
OEM Flowserve
Este cierre debe ser solo instalado, manipulado y mantenido por personal especialista autorizado,
prestando máxima atención a estas instrucciones y otras normas relevantes. Omitirlas releva al
fabricante de cualquier responsabilidad y/o garantía.
En el interés de desarrollo continuo, John Crane se reserva el derecho de cambiar
el diseño y datos específicos sin el aviso previo.
Para contactar con su centro John Crane más cercano, Póngase en contacto con uno de las
localizaciones que puede ver más abajo
Contenido
1 General ....................................................................................................3
1.1 Introducción ..............................................................................................3
1.2 Campo de Aplicación ................................................................................3
2 Seguridad y Medioambiente...................................................................3
2.1 Simbolos ...................................................................................................3
2.2 Instrucciones de Seguridad. ......................................................................3
2.3 Aspectos medioambientales .....................................................................4
2.3.1 Extracto de la política de Cía ..........................................................4
2.3.2 Reciclado........................................................................................4
3 Almacenamiento/Transporte ..................................................................5
4 Descripción del Cierre Mecánico ...........................................................5
4.1 Construction..............................................................................................5
4.2 Función .....................................................................................................6
4.3 Condiciones de Operación ........................................................................6
5 Instalación y retirada ..............................................................................6
5.1 Preparación para montaje .........................................................................6
5.2 Tolerancias de Montaje .............................................................................6
5.2.1 Tolerancias de forma y posicionales ...............................................7
5.2.2 Acabado de las Superficies ............................................................7
5.3 Instalación.................................................................................................7
5.3.1 Pares de apriete. ............................................................................9
5.3.2 Lubricantes .....................................................................................9
5.4 Retirada del cierre.....................................................................................9
5.5 Instalación/retirada de las Fijaciones Cónicas (suministro J. Crane*)......10
6 Aceptación entrega y Retirada.............................................................10
7 Mantenimiento/Reparación ..................................................................14
7.1 Mantenimiento ........................................................................................14
7.2 Recuperación..........................................................................................15
7.3 Repuestos...............................................................................................16
8 Mal funcionamiento, Causas y Corrección ........................................16
9 Documentación adjunta .......................................................................16
Page: 3 Manual de Instruciones
of: 16
Edicion 7.6
8BER
Peligro
Instrucciones obligatorias
orientadas a prevenir daños
personales ó importantes.
Page: 4 Manual de Instruciones
of: 16
Edicion 7.6
8BER
ATENCION
Si el equipo va a trabajar en zonas 21 ó 22 es 2.3.2 Reciclado
necesario limpiar con frecuencia las superficies
exteriores.. Recuperción del producto
Es peligroso fumar cuando se manejan productos Este producto se ha diseñado para su
de PTFE. potencial reutilización. Dependiendo de su
aplicación, el cierre puede ser reparado or
No hay que quemar nunca compuestos que reconstruido para se reutilzado. Todas las
contengan PTFE, vitón ó perfluorelastómero ya partes metálicas pueden ser reutilizadas. Los
que los humos y residuos son muy tóxicos. Si por
asientos y caras pueden ser relapeados y
accidente ocurre, hay que usar equipo de
protección, ya que puede haber ácido fluorhídrico. reutilizados. Se sustituyen resortes y
prisioneros de arrastre. Deben sustituirse las
Hay que seguir las normativas locales que juntas. Consultar J. Crane para dictaminar el
apliquen para el tratamiento adecuado de los estado del cierre y su potencial recuperación.
residuos de los lubricantes, fluidos ó Sólo los Ingenieros cualificados de J. Crane
elementos de deshecho. en las Unidades de soporte al Cliente
autorizadas podrán realizar la recuperación /
acondicionado de este producto
2.3 Aspectos medioambientales
Retirada
2.3.1 Extracto de la política de Cía Cuando se considera que el estado del
“Es política de J. Crane desarrollar su producto no permite su reparación
actividad de negocio de forma responsable económicamente interesante ni su
con el medio ambiente, cumplir todas las reutilización se retirará con respeto al medio
normas que apliquen, impedir la ambiente pudiéndose desmontar según
contaminación y mejorar su gestión convenga.
medioambiental. La última certificaión ISO
14001 lo acredita.“
Componentes rechazados
John C. adopta el principio Diseño Se manejarán con mucho cuidado debido a
mediambiental“ al fabricar este producto. su posible contaminación. Se reciclarán en
Usando este producto se beneficia el medio las plantas de reciclado locales.
ambiente:
Materiales especiales
Reduciendo los deshechos de recursos Seguir la normativa que aplique para el
preciosos disminuyendo el riesgo de fuga correcto tratamiento de los residuos. Los
y minimizando el consumo de energía. componentes con contenido en PTFE, Vitón o
Evitando la contaminación controlando Perfluoreslastómero no se quemarán jamás
las emisiones perniciosas a la atmófera. ya que los residuos y los humos son muy
tóxicos. (Ver instrucciones de seguridad
Conservando los materiales valiosos y
Sección 2.2)
los recursos reutilizando esos elementos
valiosos cuya duración permite su
reutilización.
Empaquetado
Todo el embalaje utilizado es de material
reciclable.
Retirada
Reponer los posicionadores
ATENCION antes de la retirada. Quitar la suciedad que se ha podido
acumular delante de la camisa.
Nota: Algunos cierres llevan agujeros de Aflojar todos los tornillos uniformemente
extracción en la tapa. Utilizar los en el sentido de las agujas del reloj, un
correspondientes tornillos para su retirada. cuarto de vuelta en la primera fase.No
sacar los tornillos .
La vibración en operaciones no
planificadas o pobres de la máquina,
y los altos niveles de
arranque/parada, pueden,
transcurrido un tiempo, aflojar los
prisiones y/o tornillos.
7.3 Repuestos
8 Mal funcionamiento, Causas
En los reacondicionados se usarán
exclusivmanete piezas John Crane.
y Corrección
Se recomienda tener en el sitio un cartucho Hay que consustar a John Crane en caso de
completo en estock o al menos las partes funcionamiento deficiente del cierre o de la
que señala el plano de instalación(Sección 9 Instalación. Se consideran condiciones
y primera página). Los códigos para pedidos anormales de funcionamiento fuga excesiva,
de los repuestos aparecen en la lista de fallo prematuro, temperaturas relativamente
partes del plano de instalación. (Sección 9 y altas.
primera página). En el caso de cierres
lubricados con gas, se almacenarán
exclusivamente cartuchos completos.
Estos son los datos necesarios para pedir 9 Documentación adjunta
repuestos:
Código del conjunto de cierre Plano de Instalación. Ver primera página
Descripción del componente para el número de plano específico.
Código del componente Hojas de Datos del cierre (si aplica).
Cantidad