Sei sulla pagina 1di 3

Proposed Project Page:

Address of Project Project No.: 15-0001


Architect Designed: b
Footing FT15
PIERS AND PADS V5.00 Demo User

Geotechnical parameters

Geotechnical report = Report (no.) dated (date)


Allowable end bearing capacity = 200 kPa at 1500 mm below finished surface (bearing material)
Allowable side friction = 30 kPa after 2000 mm below finished surface (friction material)
Material description = 200mm into stiff clay at the base of fill or silt

Pier dimension = 600 mm Base area = 0.283 m²


Pier shape = C (C)ircular,(S)quare Perimeter = 1.885 m

Reduce by concrete self weight of = 25.0 kN/m³ to 600 mm below finished surface (fill)
Then reduce by concrete self weight of = 6.0 kN/m³ thereafter
Concrete self weight for uplift = 25.0 kN/m³

Pier capacities - socket into bearing soils, 1500mm depth below finished surface

Interval = 250 mm

Depth Socket Bear. Cap. Fr. Cap SW in Fill SW in Natural Capacity øUplif
mm mm kN kN kN kN kN kN
0 0 0.0 0.0 0.0 0.0 0.0 0.0
250 0 0.0 0.0 -1.8 0.0 0.0 1.6
500 0 0.0 0.0 -3.5 0.0 0.0 3.2
750 0 0.0 0.0 -4.2 -0.3 0.0 4.8
1000 0 0.0 0.0 -4.2 -0.7 0.0 6.4
1250 0 0.0 0.0 -4.2 -1.1 0.0 8.0
1500 0 56.5 0.0 -4.2 -1.5 50.8 9.5
1750 250 56.5 0.0 -4.2 -2.0 50.4 11.1
2000 500 56.5 0.0 -4.2 -2.4 49.9 12.7
2250 750 56.5 14.1 -4.2 -2.8 63.6 27.0
2500 1000 56.5 28.3 -4.2 -3.2 77.4 41.4
2750 1250 56.5 42.4 -4.2 -3.6 91.1 55.7
3000 1500 56.5 56.5 -4.2 -4.1 104.8 70.0
3250 1750 56.5 70.7 -4.2 -4.5 118.5 84.3
3500 2000 56.5 84.8 -4.2 -4.9 132.2 98.6
3750 2250 56.5 99.0 -4.2 -5.3 145.9 112.9
4000 2500 56.5 113.1 -4.2 -5.8 159.6 127.2
4250 2750 56.5 127.2 -4.2 -6.2 173.3 141.5
4500 3000 56.5 141.4 -4.2 -6.6 187.1 155.9
4750 3250 56.5 155.5 -4.2 -7.0 200.8 170.2
5000 3500 56.5 169.6 -4.2 -7.5 214.5 184.5
5250 3750 56.5 183.8 -4.2 -7.9 228.2 198.8
5500 4000 56.5 197.9 -4.2 -8.3 241.9 213.1
5750 4250 56.5 212.1 -4.2 -8.7 255.6 227.4
6000 4500 56.5 226.2 -4.2 -9.2 269.3 241.7
6250 4750 56.5 240.3 -4.2 -9.6 283.1 256.1
6500 5000 56.5 254.5 -4.2 -10.0 296.8 270.4
6750 5250 56.5 268.6 -4.2 -10.4 310.5 284.7
7000 5500 56.5 282.7 -4.2 -10.9 324.2 299.0
7250 5750 56.5 296.9 -4.2 -11.3 337.9 313.3
7500 6000 56.5 311.0 -4.2 -11.7 351.6 327.6
7750 6250 56.5 325.2 -4.2 -12.1 365.3 341.9
8000 6500 56.5 339.3 -4.2 -12.6 379.0 356.3
8250 6750 56.5 353.4 -4.2 -13.0 392.8 370.6
8500 7000 56.5 367.6 -4.2 -13.4 406.5 384.9
8750 7250 56.5 381.7 -4.2 -13.8 420.2 399.2
9000 7500 56.5 395.8 -4.2 -14.3 433.9 413.5
9250 7750 56.5 410.0 -4.2 -14.7 447.6 427.8
9500 8000 56.5 424.1 -4.2 -15.1 461.3 442.1
9750 8250 56.5 438.3 -4.2 -15.5 475.0 456.5
10000 8500 56.5 452.4 -4.2 -15.9 488.8 470.8
Notes:

Pier depth calculator:

Capacity (SWL) = 100.0 kN


Depth below surface = 3490 mm Not solved

Bearing socket = 1990 mm


End bearing = 56.5 kN

Friction socket = 1490 mm


Side friction = 84.3 kN

Depth in fill = 600 mm


SW in fill = -4.2 kN

Depth in fill = 2890 mm


SW in natural = -4.9 kN

Capacity = 131.7 kN
øUplift = 98.0 kN

Error = 31.7 kN

Uplif:
Uplift considers the self weight of the footing
and side friction. Base suction is ignored.
ø=0.9 in accordance with AS1170.0