Standard Specifications
• Porting to: 16" Flange • Filter Media: Coalescing, Particulate,
• Flows to: 37,000 SCFM (63,000 m3/hr) Vapor Adsorption, and Bulk Liquid Removal
• Design: ASME Code/CRN (Canadian Registration) • Configuration: Floor-Standing or Line-Mounted
• Max. Temp: 450°F • Drain and Vent Ports: ½" NPT
• Max. Pressure: 185 PSIG (unless cutom designed) • Design allows for easy element changeout
Typical Applications
Coalescing (Oil Removal) Interceptor (Particulate Removal) Adsorber (Vapor Removal)
Compressed air system protection Natural gas inlet systems Odor removal
Dryer protection - Mist eliminator Desiccant dryer afterfilter Food packaging
Paint spray booths Prefilter for coalescer Powder paint systems
Microelectronics quality air Systems with high particulate Blow molding
prefiltration concentration
Landfill gas Particulate protection for Breathing air
non-lubricated systems
Natural gas treatment
2
Compressed Air Standards and Applications
I
SO 8573-1 is an international describe 1) particulate contamination definite order: the solid particulate
standard that has become the concentration, 2) liquid or vaporous class, followed by the water
universally accepted method for water contamination concentration, contamination class, and finally the
specifying and testing the purity and 3) the contamination oil contamination class. Use the
of compressed air. ISO 8573-1 concentration caused by oil in the table below to see how the purity
specifies a purity “class” based liquid, aerosol, and vapor states. classes for each contaminant type
on contaminants in compressed The ISO purity class is always are defined.
air. There are three classes that stated using three numbers in a
Notification
as specified in ISO 8573-1
Class Solid Water Oil
Maximum Maximum Maximum Maximum
Particle Concentration Pressure Dew point Concentration
Size
µm ppm (mg/m3) F
o
(oC) ppm (mg/m3)
1 0.1 0.08 (0.1) -94 (-70) 0.008 (0.01)
2 1 0.8 (1) -40 (-40) 0.08 (0.1)
3 5 4.2 (5) -4 (-20) 0.83 (1)
4 15 6.7 (8) 37 (+3) 4.2 (5)
5 40 8.3 (10) 45 (+7) 21 (25)
6 - - - 50 (+10) - -
Typical Applications
ISO Class 2 Solid Water 3 Oil ISO Class 1 Solid 4 Water 1 Oil
ISO Class 2 Solid 4 Water 3 Oil ISO Class 1 Solid 2 Water 1 Oil
Note: In the pictorial examples shown above, the contribution of hydrocarbon vapors has not been taken into account in determining the oil class category. 3
Determine your application, media grade, media type and end seals.
Find your (or similar) application from the descriptions below, from the basic application circuits on the previous page,
or consult a Finite application engineer. Determine media grade, media type, and end seal required. If your application
requires a coalescing element, use the information listed below. For other media types, please see the following page.
4
Water Separator Element Interceptor Element Adsorption Element
(removal of bulk liquids) (removal of particulate) (removal of odor)
This all stainless steel mesh This particulate element is This hydrocarbon vapor removal
element has two metal retainers constructed of pleated cellulose element consists of an ultrafine
with rolled mesh steel in between. with a 3 micron rating. It is metal grained, highly concentrated,
It is an extremely robust design. retained for added strength and activated carbon sheet media. It is
includes an outer handling layer. metal retained for added strength
This media is used for the and includes an outer synthetic fabric
reduction and elimination of 3P particulate interceptor layer.
excess liquids in gas streams. elements are used where high dirt
Excellent prefiltration for holding capacity and relatively fine
coalescing grades 6 and 10 pore structure are required.
when extreme quantities of liquid
contaminants are present.
5
Housing Selection Chart
Housing Replace- Port Port Type Number Rated Flows:
Assembly ment Size of SCFM@ 100 PSIG (m3hr@ 7 bar)
(Inches)
Number Element Elements
Number Grade 6/A Grade 8 Grade
ME/7CVP/10/
100WS/3P
Line-Mount Vessels
HT3-801 51-280 3 NPT 1 1500 (2540) 1800 (3050) 2490 (4230)
Floor-Standing Vessels
HF3-801 51-280 3 NPT 1 1500 (2540) 1800 (3050) 2490 (4230)
How to Order
Complete Assembly*:
Housing Assembly Number - Media Grade Media Type End Seals See pages
4-5 for more
(from chart above) information on
6 C U - Urethane can be used for media grades,
Examples: 8 Q media types: C, Q, and 3P. types, and end
seals.
10 D
Note: Only ME S - Silicone rubber can be used for
FF3-801-6QU
add media media types C, Q, D, and 3P.
FF6-1603-7CVP 7CVP
grade for C, Q
7DVP
*complete assembly includes vessel &D V - Fluorocarbon can be used on
and elements. Elements are shipped 100WS C, Q, D, 3P. Standard on ME,
separately from vessel. 3P 7CVP, 7DVP, 100WS, and A.
A
1/4 NPT
A Gauge D 1/2 NPT 1/2 NPT
Ports 1/4 NPT A Drain Drain
D Gauge A
A D D
Ports 1/4 NPT 1/4 NPT
Gauge Gauge
Port Port
E E
1/2 NPT 1/2 NPT
1/2 NPT 1/2 NPT Drain
Drain Drain
Drain Refer to this
Refer to this Refer to this Refer to this drawing for:
drawing for: drawing for: drawing for: FF6-1603
HT3-801(NPT) FT6-1603 HF3-801(NPT) FF8-1804
FT3-801 FF3-801
FT4-1201 FF4-1201
FT6-1201 FF6-1201
KBDPG-15 KBDPI-25
Differential Pressure Gauge Kit Differential Pressure Gauge Kit
Drains
Finite offers several choices of automatic drains, ranging from simple float actuated drains, programmable
solenoid types, and smart zero-air loss drains, which conserve energy by only draining when liquid is present.
ADT-50 ZLD-023
Float Actuated Drain Trap Zero Air Loss Condensate Drain
TV-50 ADS-50
Timed Solenoid Valve Drain Trap Float Actuated Stainless Steel
Drain Trap
• 1/2" NPT Connection • 304 stainless steel
• Electrical connection = 110 vAC construction
• Other Models Available • 1/2" NPT Inlet and Outlet
Connections