Sei sulla pagina 1di 5

Bedienungsanleitung

Operating instructions
Instructions d’emploi
Instrucciones de
servicio
Manual de instruções
Istruzioni d’uso
Gebruiksaanwijzing
Betjeningsvejledning
AL 1404
Bruksanvisning AL 2404
Brukerveiledningen
Käyttöohje
Οδηγία χειρισµού
Kullanım kılavuzu

Deutsch
English
Français
Español
Português
Italiano
Nederlands
Dansk
Svenska
Norsk
Suomi
Ελληνικά
Türkçe
1

APT

APT

AL 1404
AL 2404
2 609 140 298 • 12.4.06
f Do not operate the battery charger on easily
Safety Rules inflammable surfaces (e. g., paper, textiles,
f Connect battery chargers that are used in the etc.) or surroundings. The heating of the battery
open via a ground fault circuit breaker. charger during the charging process can pose a fire
f Keep the battery charger away from rain or hazard.
moisture. Penetration of water in the battery
charger increases the risk of an electric shock.
f Do not charge other batteries. The battery
Functional Description
charger is suitable only for charging Bosch Read all safety warnings and all
NiCd/NiMH batteries with the voltages listed in the instructions. Failure to follow the
technical data. Otherwise there is danger of fire and warnings and instructions may result in
explosion. electric shock, fire and/or serious injury.
f Keep the battery charger clean. Contamination Save these instructions.
can lead to danger of an electric shock.
f Before each use, check the battery charger, Product Features
cable and plug. If damage is detected, do not
use the battery charger. Never open the bat- The numbering of the product features refers to the
tery charger yourself. Have repairs performed illustration of the battery charger on the graphics page.
only by a qualified technician and only using
1 Battery with contact APT*
original spare parts. Damaged battery chargers,
cables and plugs increase the risk of an electric 2 Charging compartment
shock. 3 Battery charge indicator
*The accessories illustrated or described are not
included as standard delivery.

Technical Data
Battery Charger AL 1404 AL 2404
Article number 2 607 225 0.. 2 607 225 1..
Output voltage (automatic voltage detection) V= 7.2–14.4 7.2–24
Charging current mA 400 400
Allowable charging temperature range °C 0–45 0–45
Charging time for battery capacity
– 1.2 Ah h 3 3
– 1.5 Ah h 4 4
– 2.0 Ah h 5 5
Weight according to EPTA-Procedure 01/2003 kg 0.4 0.6
Protection class / II / II
Please observe the article number on the type plate of your battery charger. The trade names of individual battery chargers may
vary.

Operation Charging Procedure


The charging procedure starts as soon as the mains
plug of the battery charger is plugged into the socket
Starting Operation outlet and the battery 1 is inserted into the charging
compartment 2.
f Observe the mains voltage! The voltage of the
The battery charge indicator 3 is not a charge-control
power supply must correspond with the data given
indicator. The lit indicator signalises the flow of charg-
on the nameplate of the battery charger. Battery
ing current.
chargers marked with 230 V can also be operated
with 220 V. The charging procedure is not ended automatically.
Therefore, disconnect the battery charger from the
mains supply after the battery has been charged and
remove the battery. A temperature increase of the bat-
tery indicates that the battery is fully charged.

2 609 140 298 • 12.4.06 English–1


WARNING! Important instructions for connecting
Operating Instructions a new 3-pin plug to the 2-wire cable.
The wires in the cable are coloured according to the fol-
With continuous or several repetitive charging cycles
lowing code:
without interruption, the charger can warm up. This is
not meaningful and does not indicate a technical defect
of the battery charger.
A battery that is new or that has not been used for a
longer period will not achieve its full capacity until after
approx. 5 charging and discharging cycles. Leave such
a battery in the battery charger until it has warmed up
considerably. Do not connect the blue or brown wire to the earth ter-
A significantly reduced working period after charging minal of the plug.
indicates that the battery is used and must be replaced. Important: If for any reason the moulded plug is
removed from the cable of this power tool, it must be
disposed of safely.
Troubleshooting – Causes and
Corrective Measures
Service and Customer Assistance
Cause Corrective Measure Exploded views and information on spare parts can be
found under:
No charging procedure possible
www.bosch-pt.com
Battery contacts contami- Clean the battery con-
nated tacts (e. g. by inserting Great Britain
and removing the battery Robert Bosch Ltd. (B.S.C.)
several times) or replace P.O. Box 98
the battery Broadwater Park
Battery defective Replace the battery North Orbital Road
Denham-Uxbridge
Battery charge indicator 3 does not light up Middlesex UB 9 5HJ
Mains plug of battery Insert mains plug (fully) ✆ Service:. . . . . . . . . . . . . . . +44 (0) 18 95 / 83 87 82
charger not plugged in into the socket outlet ✆ Advice line:. . . . . . . . . . . . +44 (0) 18 95 / 83 87 91
(properly) Fax: . . . . . . . . . . . . . . . . . . . . +44 (0) 18 95 / 83 87 89
Battery not inserted (prop- Insert battery (fully) into Ireland
erly) the battery charging com- Beaver Distribution Ltd.
partment Greenhills Road
Socket outlet, mains cable Check the mains voltage; Tallaght-Dublin 24
or battery charger defec- have the battery charger ✆ Service:. . . . . . . . . . . . . . . . .+353 (0)1 / 4 14 94 00
tive checked by an authorised Fax: . . . . . . . . . . . . . . . . . . . . . .+353 (0)1 / 4 59 80 30
after-sales service agent
for Bosch power tools Australia and New Zealand
Robert Bosch Australia Pty. Ltd.
RBAU/SPT
1555 Centre Road
P.O. Box 66
Maintenance and Service 3168 Clayton/Victoria
✆ . . . . . . . . . . . . . . . . . . . . . +61 (0)1 / 3 00 30 70 44
Fax: . . . . . . . . . . . . . . . . . . . . +61 (0)1 / 3 00 30 70 45
Maintenance and Cleaning www.bosch.com.au
If the battery charger should fail despite the care taken
in manufacturing and testing procedures, repair should
be carried out by an authorised after-sales service
agent for Bosch power tools.
In all correspondence and spare parts orders, please
always include the 10-digit article number on the type
plate of the battery charger.

2 609 140 298 • 12.4.06 English–2


Disposal
Battery chargers, accessories and packaging should
be sorted for environmental-friendly recycling.
Only for EC countries:
Do not dispose of battery chargers into
household waste!
According to the European Guideline
2002/96/EG for Waste Electrical and
Electronic Equipment and its implemen-
tation into national right, battery charg-
ers that are no longer usable must be collected
separately and disposed of in an environmental correct
manner.
Subject to change without notice.