Sei sulla pagina 1di 4

biosanitizer-automate

disinfects all surfaces in less than 30 minutes!


biosanitizer-automate
disinfect invisible surfaces

With biosanitizer-automate, you auto- effective


mate the tedious work that represent The microbiological activity is provided by
a manual disinfection of surfaces often the eco-friendly biosanitizer S, a water-based
sloppy due to lack of time. With it, you disinfectant with only <2% or R <6% hy-
disinfect everywhere and eliminate the drogen peroxide. The automate is equipped
risk of cross-contamination for the staff with a patented heated venturi-system, en-
members and patients , while ensuring hancing the microbial activity of the prod-
optimal microbiological efficacy with- uct. With a daily disinfection the bacterial
out creating germs resistance. These background can be neutralised to its low-
are some of the many advantages of est level in 7 days. biosanitizer S meets the
the biosanitizer-automate. requirements of Medical Devices Directives
93/42 /EEC, benefits from the Swiss certifi-
cation standards and Swiss CE1253 safety
Healthcare associated infections, noso- The automate will trigger the calculated dis- mark, tested according to European stand-
comial pathogens or “superbugs” are infection of the room volume to be treated ard testing method and tested to those of
increasingly becoming a major issue and the biosanitizer ml needed. It will turn DGHM / VAH in Germany. 7A study con-
for senior clinicians and administrators off automatically at the end of the cycle. ducted in Switzerland by a notify laboratory
in healthcare organisations around Only a few minutes are sufficient to disin- confirmed these results by drawing on the
the world. Saniswiss revolutionary fect the entire air and surfaces (3 minutes for last French standard NF T 72 281.
technology is proven to be effective 20m3), including those that you can achieve
against a wide range of environmen- with the naked eye.
tally associated nosocomial pathogens,
including methicillin-resistant Staphy- ingenious
lococcus aureus (MRSA), Clostridium Our revolutionary system upsets standards before
difficile, vancomycin-resistant entero- of mechanical surface disinfection often
cocci (VRE), norovirus and other bacte- random. The combination of the biosani-
ria Gram negatives and Gram positives. tizer antimicrobial and the automate brings
after
Ecological and water-based biodegrad- reproducible microbiological results. The
able, our technology adapts the special disinfection operation is carried out auto-
needs of several specific areas of need. matically with the advantage of not neglect
some hard to reach surfaces with a wipes.

exceeds standards
bactericide activity comply with fungi, yeast, activity comply with virucide activity (<30 secondes)
EN 1040, EN 14561, EN 13727, EN 1275, EN 1650, EN 13624 • HBV
EN 1276, (< 30 seconds) EN 14562 (< 5 minutes) • HCV
• pseudomonas aeruginosa • candida albicans • HIV
• escherichia coli • aspergillus niger • BVDV
• enterococcus hirae • human influenza
• staphylococcus aureus tuberculosis activity comply • SRAS
• proteus vulgaris with EN 14348 • vaccinia
• staphylococcus epidermis • mycobacterium avium • H5N1
• MRSA • mycobacterium terrae • H1N1
• clostridium difficile cells
• listeria spores activity comply activity complies with EN 14476
• streptococcus pyogenes with EN 13704 • norovirus
• salmonella typhimurium • clostridium difficile spores • adénovirus
• shigella sonnei • rhinovirus
• klebsiella pneumoniae • rotavirus
• proteur mirabilis
medical device Class IIa
.
cost-effective safe rapid room recovering
Portable, the automate can be installed any- The operation is carried out of human pres- biosanitizer-automate disinfects all surfaces
where. A single automate can disinfect ence safely. It leaves no trace, not wet, it is and air in an average room in less than 30
several rooms and treats up to 350 m3. The not risk to surfaces or electronic equipment. minutes. The room can be used immediately
operation requires only a minimum dose of A protocol for use supplied with the control- after aeration of its volume.
biosanitizer (3 ml/m3). 8It must be repeated ler guarantees perfect sound job.
regularly to maintain level reached.

non-toxic
Unlike «classical-chemical» products, biosan-
itizer S and R do not contain peracetic acid.
It guarantees maximum safety for the user,
environment and the treated material. After
use, it leaves a neutral and pleasant odor in
the treated room.

time and volume setting aerosolisation aHP

Xn : harmful F : highly N : dangerous for C : corrosive


Xi : irritant flammable the environment
biosanitizer-automate
multiple field of use

santé : salle d’opération, chambre d’hôpital,


cabinet dentaire, ambulance, laboratoire...

developed for the healthcare useful elsewhere


Originally, our system of automatic airborne dis- The problem of infection control is not limited to
infection was developed to address the cross- specific areas of medicine. For this reason our sys-
infection issues of healthcare professionals, such tem may be used in various application areas such
as: hospitals, medical offices, dental offices, as: transport (air, rail, maritime, road), nurseries,
laboratories, homes retirement, rehabilitation schools, child care, restaurant, police, industries,
places, places of quarantine and ambulances. hotels and funeral.

bsa022015EN
characteristics
power 1000 W
tension 230 V
frequency 50 à 60 Hz
intensity 4,5 A
maixmum intensity 10 A
speed of turbine 22000 t/min
tank capacity 750 ml
weight 9,8 kg
net weight 9 kg
size W29  x H39 x L53,6 cm

performances
speed-exit of air 80 m/s
max. volume to be treated 350 m3
average output 350 ml/h
consumption 3 ml/m3

options
timer, wall-adapter,
bottles 750 ml, 1000 ml, can 5000 ml

saniswiss sa • chemin des tulipiers 19 • 1208 Genève • Switzerland • t +41 22 718 75 75 • f +41 22 718 75 76 • info@saniswiss.com • saniswiss.com
saniswiss sa is an ISO 13485 certified company. All saniswiss™ products have the CE 1253 mark.

Potrebbero piacerti anche