Cntr. No. Description Units Count Conditions
301 Truck Life Hours The number of calendar hours that have elapsed since the
CPU has been loaded with its current version of software.
NOTE: This counter only has non–zero values in the
Lifetime Counter column.
302 Control Power On Hours The number of hours that the control power relay (CPR) has
been energized.
303 Engine Operate Hours The number of hours of engine operation above the engine
running threshold criteria.
304 Engine Idle Hours The number of hours when engine is idling and truck is sta-
tionary.
305 Truck Operate Hours The summation of the number of hours that the propulsion
system has operated in propulsion, retard, ready and test.
306 Truck Parked Hours The number of hours that the Park Brake applied feedback is
true while TCI is energized.
307 Truck Travel Miles The cumulative miles travelled by the truck. It is a calculated
value, based upon the integrated average of the four wheel-
motor speed signals. It is active when control power is on,
and it is not sensitive to vehicle direction.
308 Truck Travel Kilometers The cumulative kilometers travelled by the truck. It is a cal-
culated value, based upon the integrated average of the four
wheelmotor speed signals. It is active when control power is
on, and it is not sensitive to vehicle direction.
309 Wheel 1 Operate Hours The number of hours that wheel #1 was providing torque in
either propulsion or retard, and was moving.
310 Wheel 2 Operate Hours The number of hours that wheel #2 was providing torque in
either propulsion or retard, and was moving.
311 Propel Forward Hours The number of hours that the truck was moving forward in
the propulsion mode of operation.
312 Retard Forward Hours The number of hours that the truck was moving forward in
the retard mode of operation.
313 Propel Mode Hours The number of hours that the truck was moving in the propul-
sion mode of operation.
314 Retard Mode Hours The number of hours that the truck was moving in the retard
mode of operation.
315 CPR Pickup Occurrences The number of times when the Keyswitch was moved from
the STOP to the ON position.
316 GF Pickup Occurrences The number of times that the GF contactor feedback has
changed from deenergized to energized indication.
317 GFR Pickup Occurrences The number of times that the GFR relay feedback has
changed from deenergized to energized indication.
318 RP1 Pickup Occurrences The number of times that the RP1 contactor feedback has
changed from deenergized to energized indication.
319 RP2 Pickup Occurrences The number of times that the RP2 contactor feedback has
changed from deenergized to energized indication.

98
VTI For 320 Ton AC OHV Propulsion Systems, GET–6864A

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
320 RP3 Pickup Occurrences The number of times that the RP3 contactor feedback has
changed from deenergized to energized indication.
321 Dump Body Up Occurrences The number of times that the Dump Body position sensor
input has changed from true to false, indicating that the dump
body has been raised.
322 Loaded Truck Occurrences The number of times that the Full Payload input has changed
from false to true.
323 Speed Set 1 Occurrences The number of times that the programmable speed set point
#1 has been exceeded.
324 Speed Set 2 Occurrences The number of times that the programmable speed set point
#2 has been exceeded.
325 Engine Start Switch Occurrences The number of times that the engine start request was actu-
ated by the operator’s Keyswitch.
326 Engine On & Start Occurrences The number of times that engine start request received while
the engine above its running threshold criteria.
327 Separate Batteries Occurrences The number of times that the control and cranking batteries
were commanded to separate.
328 Engine Crank Occurrences The number of times that a crank command has been issued
to the engine.
329 Engine Starts Occurrences The number of times that the measured engine speed has
exceeded the engine running criteria.
330 Engine Off Occurrences The number of times that the Engine Kill pushbutton was ac-
tuated.
331 Park Brake Request Occurrences The number of times that the Park Brake switch was actu-
ated.
332 Park Brake Applied Occurrences The number of times that the Park Brake pressure switch
feedback transitioned from false to true, indicating that the
Park Brake was applied.
333 SS to Reverse Occurrences The number of times that the Direction Selector switch was
moved to the Reverse position.
334 SS to Forward Occurrences The number of times that the Direction Selector switch was
moved to the Forward position.
335 SS When Moving Occurrences The number of times that the Direction Selector switch was
moved to command a change in direction while the truck was
moving.
336 RSC Switch On Occurrences The number of times that the Retard Speed Control switch was
moved from Off to On.
337 Rest Request Occurrences The number of times that the rest request was received by ac-
tuation of the Rest Request switch.
338 Override Switch Occurrences The number of times that the override command was received
by actuation of the Override switch.
339 Lamp Test Switch Occurrences The number of times that the lamp test request was received by
actuation of the Lamp Test switch.

99
GET–6864A, VTI For 320 Ton AC OHV Propulsion Systems

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
340 Engine Cautions Occurrences The number of times that the Engine Cautions signal from the
Engine Controller transitioned from low to high.
341 Engine OEM Over- Occurrences The number of times that the Engine Speed increases above
speed an OEM–selected limit.
342 Load Brake Occurrences (150 Ton) The number of times that the Load Brake input
transitioned from low to high.
343 Load Brake Seconds The amount of time that the Load Brake is applied.
344 Service Brake at Occurrences The number of times that the Service Brake is applied at
Speed speed.
345 Service Brake at Seconds The amount of time that the Service Brake is applied at
Speed speed.
346 Aux Shutdowns Occurrences The number of times that the aux_shutdown signal transi-
tioned from low to high.
347 Starter Failure Occurrences The number of times the engine_starter_fail_di24 input tran-
sitions to true.
348 Coasting Hours The number of hours that are spent coasting. Ready mode
is active and Wheel #1 or Wheel #2 speed is above 50 rpm.
349 Rest Hours The number of hours that are spent in the Rest mode. Rest
mode is active.
350 Test Hours The number of hours that are spent in the Test mode. Test
mode is active.
351 Enter READY Occurrences The number of times that the READY mode has been en-
tered.
352 Enter Test Occurrences The number of times that the Test mode has been entered.
353 Enter Propel Occurrences The number of times that the Propel mode has been entered.
354 Enter Retard Occurrences The number of times that the Retard mode has been en-
tered.
355 Speed Control Ac- Occurrences The number of times that propel torque is regulated in the
tive speed limit mode.
356 M1 Spin Time Seconds The number of seconds that Wheel #1 Spin Control is active.
357 M1 Slide Time Seconds The number of seconds that Wheel #1 Slide Control is active.
358 M2 Spin Time Seconds The number of seconds that Wheel #2 Spin Control is active.
359 M2 Slide Time Seconds The number of seconds that Wheel #2 Slide Control is active.
360 M1 Spin Count Occurrences The number of times that Wheel #1 Spin Control is active.
361 M1 Slide Count Occurrences The number of times that Wheel #1 Slide Control is active.
362 M2 Spin Count Occurrences The number of times that Wheel #2 Spin Control is active.
363 M2 Slide Count Occurrences The number of times that Wheel #2 Slide Control is active.
364 Service Brake Time Seconds The number of seconds that the wet brake is applied and
truck speed is > no motion speed.
365 Service Brake App Occurrences The number of times that the wet brake is applied and truck
speed is > no motion speed.
366 Load Box Mode Seconds The number of seconds that the system is in load box mode.

100
VTI For 320 Ton AC OHV Propulsion Systems, GET–6864A

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
Note: Parameter Numbers 1000 through 1099 correspond to DID Panel PSC Events 000 through 099,
respectively (shown on DID panel and wPTU Toolbox).
1000 spare
1001 spare
1002 Ground Fault Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1003 Failed Diode Panel Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1004 GFCO Not Reset Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1005 Propulsion System Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Over Temp
1006 Both Inv Comms Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Failed
1007 spare
1008 DC Link Over Volt Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1009 ALTF Over Amps Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1010 spare
1011 Retard Lever Signal Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1012 Retard Pedal Signal Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1013 Mid V Failure Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1014 Analog Sensor Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Faults
1015 Restrictive Analog Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Sensor Fault
1016 PSC CPU Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Fault
1017 FB104 Digital Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1018 FB143 Analog Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1019 Riding Retard Pedal Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1020 High Torque Limit Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1021 TCI Comm Fault Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1022 Persistent TCI Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Comm Fault
1023 Tertiary Overcurrent Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1024 CFG File Error Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1025 Blower Fault Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1026 Cap Overpressure Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1027 Panel Not Con- Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
nected at Power Up
1028 spare
1029 spare

101
GET–6864A, VTI For 320 Ton AC OHV Propulsion Systems

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
1030 GF Contactor Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1031 Battery Boost Circuit Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1032 RP Contactors Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1033 RP–HP Balance Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1034 spare
1035 ESS Input Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1036 Grid Blower Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1037 Computer Power Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Supply
1038 spare
1039 spare
1040 24V Positive Bad Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1041 24V Negative Bad Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1042 Self Load & Dir Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1043 Battery Volt Low Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1044 Battery Volt High Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1045 Chopper Open Cir- Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
cuit
1046 Retard Circuit Short Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1047 Engine Stall Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1048 Shorted DC Link Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1049 spare
1050 spare
1051 Tach Left Rear Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1052 Tach Right Rear Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1053 FLeft Speed Sig Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1054 FRight Speed Sig Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1055 Front Wheel Tachs Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1056 Inverter SW Version Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1057 spare
1058 spare
1059 spare
1060 spare
1061 Motor Over Speed Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1062 spare
1063 Engine Load Sig Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1064 spare

102
VTI For 320 Ton AC OHV Propulsion Systems, GET–6864A

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
1065 Temp Input Bad Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1066 spare
1067 spare
1068 spare
1069 spare
1070 Link Cap Level Get- Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
ting Low
1071 Link Cap Level Too Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Low
1072 Ground Fault Circuit Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Problem
1073 Sensor Offset Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1074 INV1 Comm Failed Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1075 INV2 Comm Failed Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1076 FB173 Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1077 Inverter Failed VI Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Test
1078 Inv Bkgnd Msg Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1079 spare
1080 spare
1081 spare
1082 spare
1083 spare
1084 CPS & Moving Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1085 Aux Cooling Fault Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1086 spare
1087 Engine HP Low Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1088 HP Over Limit Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1089 Engine Speed Com- Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
mand
1090 spare
1091 INV1 Cutout Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1092 INV2 Cutout Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1093 spare
1094 Limp Req Error Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1095 BBRAM Error Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1096 Unexpected System Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Reset

103
GET–6864A, VTI For 320 Ton AC OHV Propulsion Systems

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
1097 spare
1098 PTU Data Store Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1099 Software Event Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS

104
VTI For 320 Ton AC OHV Propulsion Systems, GET–6864A

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
Note: Parameter Numbers 1100 through 1199 correspond to Inverter #1 Event Codes
100 through 199, respectively (shown on DID panel and wPTU Toolbox).
1100 INV1 CPU Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1101 INV1 CPU NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1102 INV1 I/O Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1103 INV1 I/O NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1104 INV1 FO Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1105 INV1 PS Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1106 INV1 DC Power Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1107 GDPS1 Fail Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1108 spare
1109 INV1 LinkV Fail Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1110 spare
1111 INV1 Input Volt Sen- Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
sor
1112 spare
1113 INV1 General Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1114 INV1 General NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1115 INV1 System Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1116 INV1 A Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1117 INV1 A+ Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1118 INV1 A+ Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1119 INV1 A– Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1120 INV1 A– Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1121 INV1 A Phase Amps Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1122 spare
1123 INV1 A Phase Volts Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1124 spare
1125 INV1 B Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1126 INV1 B+ Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1127 INV1 B+ Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1128 INV1 B– Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1129 INV1 B– Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1130 INV1 B Phase Amps Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1131 spare
1132 INV1 B Phase Volts Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1133 spare

105
GET–6864A, VTI For 320 Ton AC OHV Propulsion Systems

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
1134 INV1 C Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1135 INV1 C+ Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1136 INV1 C+ Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1137 INV1 C– Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1138 INV1 C– Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1139 spare
1140 spare
1141 INV1 C Phase Volts Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1142 spare
1143 INV1 Tach 1 Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1144 INV1 Tach 1 NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1145 INV1 Tach 2 Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1146 INV1 Tach 2 NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1147 spare
1148 Chopper 1 NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1149 spare
1150 Chopper 2 NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1151 INV1 Misc Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1152 spare
1153 INV1 Motor Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1154 INV1 Motor Faults Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
NR
1155 INV1 Second Load Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1156 thru spare
1199

106
VTI For 320 Ton AC OHV Propulsion Systems, GET–6864A

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
Note: Parameter Numbers 1200 through 1299 correspond to Inverter #2 Event Codes
200 through 299, respectively (shown on DID panel and wPTU Toolbox).
1200 INV2 CPU Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1201 INV2 CPU NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1202 INV2 I/O Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1203 INV2 I/O NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1204 INV2 FO Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1205 INV2 PS Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1206 INV2 DC Power Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1207 GDPS2 Fail Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1208 spare
1209 INV2 LinkV Fail Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1210 spare
1211 INV2 Input Volt Sen- Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
sor
1212 spare
1213 INV2 General Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1214 INV2 General NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1215 INV2 System Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1216 INV2 A Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1217 INV2 A+ Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1218 INV2 A+ Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1219 INV2 A– Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1220 INV2 A– Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1221 INV2 A Phase Amps Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1222 spare
1223 INV2 A Phase Volts Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1224 spare
1225 INV2 B Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1226 INV2 B+ Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1227 INV2 B+ Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1228 INV2 B– Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1229 INV2 B– Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1230 INV2 B Phase Amps Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1231 spare
1232 INV2 B Phase Volts Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1233 spare

107
GET–6864A, VTI For 320 Ton AC OHV Propulsion Systems

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
1234 INV2 C Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1235 INV2 C+ Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1236 INV2 C+ Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1237 INV2 C– Phase Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1238 INV2 C– Phase NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1239 spare
1240 spare
1241 INV2 C Phase Volts Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1242 spare
1243 INV2 Tach 1 Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1244 INV2 Tach 1 NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1245 INV2 Tach 2 Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1246 INV2 Tach 2 NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1247 spare
1248 Chopper 1 NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1249 spare
1250 Chopper 2 NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1251 INV2 Misc Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1252 spare
1253 INV2 Motor Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1254 INV2 Motor Faults Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
NR
1255 INV2 Second Load Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1256 thru spare
1299

108
VTI For 320 Ton AC OHV Propulsion Systems, GET–6864A

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
Note: Parameter Numbers 1600 through 1699 correspond to TCI Events 600 through 699,
respectively (shown on DID panel and wPTU Toolbox).
1600 spare
1601 FB144 CPU Card Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1602 FB104 Digital I/O Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1603 FB160 Analog I/O Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1604 PSC Comm Bad Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1605 Aux Comm Fault Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1606 spare
1607 5V Positive Bad Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1608 15V Positive Bad Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1609 15V Negative Bad Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1610 Pot Ref Bad Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1611 spare
1612 spare
1613 Analog Input Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1614 BSep Cont Fail Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1615 spare
1616 Forin & Revin Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1617 Eng Start Denied Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1618 spare
1619 Engine Warning Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1620 Eng Kill & Speed Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1621 spare
1622 Park Brake Problem Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1623 Hyd Brake Fluid Hot Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1624 Body Up & Load Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1625 Body Up & Speed Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1626 Load Brake & Speed Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1627 spare
1628 Battery Volts Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1629 Baro Press Signal Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1630 Motor Blower Press Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1631 Amb Temp Signal Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1632 CFG File Error Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1633 BBRAM Error Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS

109
GET–6864A, VTI For 320 Ton AC OHV Propulsion Systems

TABLE 3. STATISTICAL DATA CODES – COUNTERS (Cont’d)


Cntr. No. Description Units Count Conditions
1634 Overload Restrictive Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1635 Overload NR Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1636 Aux Inverter Faults Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1637 spare
1638 Engine Crank Time- Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
out
1639 Engine Start Re- Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
quest & Running
1640 Accel Pedal too High Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1641 Accel Pedal too Low Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1642 Crank Override Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1643 thru spare
1690
1691 spare
1692 spare
1693 spare
1694 spare
1695 spare
1696 Unexpected CPU Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
Reset
1697 spare
1698 Data Store Occurrences See TABLE 5 – EVENT CODE DESCRIPTIONS
1699 spare

110