ELECTRICAL QUESTIONS

1. WHAT IS QC INSPECTOR RESPONSIBILTY?

ANS: ALL REQUIRED QUALITY RECORDS AND SUMMARY ACCORDING TO QCP HAVE BEEN
ISSUED AND APPROVED. SHALL ENSURE ALL WORKS NECESSARY FOR THE PREPATRATION
AND PERFORMANCE OF INSPECTIONS,EXAMINATIONS, AND TESTS INCULDING EQUIPMENTS ,
TOOLS.ENSURE THAT ALL THE NCR HAVE BEEN CLOSED OUT.

2. WHAT IS NCR?
ANS: NON CONFORMANCE REPORT
ANY DEVIATION TO STANDARDS AND PROCEDURES RELATED TO CONTRACTORS

3. WHAT IS SCHDULE Q?

ANS:
THE MINIMUM REQUIRMENTS FOR CONTRACTORS QUALITY MANAGEMENT SYSTEM.

4. WHAT IS HI-POT TESTING?

ANS: HIGH POTENTIONAL TESTING

5. TYPES OF XFR?

ANS: POWER XFR , TRY TYPE XFR, OVER HEAD DISTRIBUTION XFR AND PAD MOUNTED
DISTRIBUTION XFR.

6. WRITE THE NEMA STANDARDS RELATED TO CONDUIT?

ANS: NEMA RN 1, NEMA TC2 , NEMA TC3, NEMA TC 6 &8, NEMA TC 9.

7. WRITE THE INSTALLATION DISTANCE BACK,SIDE AND FRONT SIDE FOR SWITCHGEAR?

ANS: 2 METER IN FRONT


1 METER IN BACK AND SIDE
8. TYPES OF ANODES?

ANS: GALVANIC ANODE (ALUMINIUM ANODES, ZINC ANODES AND MEGNISIUM ANODE)
IMPRESSED CURRENT ANODES

9. WRITE THE EXPANSION GAP FOR ALUMINIUM CABLE TRAY?

ANS: THE EXPANSION GAP SETTINGS ACCORDACE TO TEMPERATURE 0 TO MAX 55 DEGREE


FOR NEMA VE2 (25MM FOR 20 METRS)

10. WRITE THE ABBRIVATION FOR NEMA VE1 AND NEMA VE2?

ANS: NEMA VE1- METAL CABLE TRAY SYSTEM INSTALLATION


NEMA VE2- CABLE TRAY INSTALLATION GUIDLINES

11. WRITE ANY 5 INTERNATIONAL STANDARDS RELATED TO ELECTRICAL?

ANS: SAES-P-100 BASIC DEIGN SYSTEM CRITERIA


SAES-P-101 - REGULATED VENDORS LIST FOR ELECTRICAL EQUIPMENT
SAES-P-103- UPS AND DC SYSTEMS
SAES-P-104- WIRING METHODS AND MATERIALS
SAES-P-107 - OVERHEAD DISTRIBUTION SYSTEMS
SAES-P-111- GROUNDING
SAES-P-113- MOTORS AND GENERATORS
SAES-P-114- POWER SYSTEM & EQUIPMENT PROTECTION
SAES-P-116- SWITCHGEAR &CONTROL EQUIPMENT
SAES-P-119- ONSHORE SUBSTATION
SAES-P-121- TRANSFORMERS & REACTORS
SAES-P-123- LIGHTING
SAES-P-126- POWER SYSTEM AUTOMATION

12. WHAT IS MEGGER? HOW TO DO THE MEGGER FOR LV CABLES?

ANS: A FOUR TERMINAL METER DESIGNED TO MEASURE THE GROUND RESISTIVITY OR


CAN BE CONNECTED TO MEASURE RESISTANCE IN A FORMAT THAT EXCLUDES THE
RESISTANCE OF TEST WIRES.

IN 1 KV MEGGER HAVE TWO TEMINAL POSITIVE AND NEGATIVE. THE POSITIVE


CONNECTED TO MAIN CABLE AND NEGATIVE CONNECTED TO THE GROUND AND
PRESS THE TEST THE VALUE SHOULD BE MEASURE. LOW VOLTAGE CABLE SHALL BE
BELOW 1 OHM.

13. WRITE THE QUALIFICATION LEVEL FOR CATHODIC PROTECTION ENGINEER AND TECHNICIAN?

ANS: CATHODIC PROTECTION ENGINEER – NACE LEVEL 3


CATHODIC PROTECTION TECHNICIAN – NACE LEVEL 2

14. WRITE THE MINIMUM BURIAL LENGTH FOR GROUND CONDUCTOR IN ROAD AND PARKING
AREAS??
ANS:
610 MM

15. WRITE THE PVC CONDUIT TYPE FOR CONCRETE ENCASED AND DIRECT BURIED?

ANS:
CONCRETE ENCASED – EB 35 (NEMA TC 6 & 8)
DIRECT BURIED - DB 120 (NEMA TC 6 & 8)

16. WRITE THE RECTIFIER TYPE FOR CATHODIC PROTECTION?


ANS:
Class AA AND CLASS OA
Class AA: Dry Type Air Cooled
Class OA: Oil Immersed Air Cooled

17. WRITE ANY 3 IEC STANDARDS FOR LIGHTNING PROTECTION?

ANS: IEC 61662, IEC 61024-1, IEC 61024-1-1

18. WRITE THE ANNUAL GROUND FLASH DENSITY FORMULA?

ANS: Ng=0.00282XlXl (Annual ground strikes per square kilometer

19. WHAT IS MATERIAL RECEVING?

ANS: MATCH PHYSICAL CONDITION IN FIELD TO SERVICE CONDITION SHOWN ON DWGS


SPECIFICATION AND MARKING COLOUR CODE AND TAGGING
IDENTIFICATION OF ALL REALTED TO STANDARDS

20. WHAT IS BASE VOLTAGE?

ANS:
THE BUS VOLTAGE CALCULATED BY STARTING THE NOMINAL VOLTAGE AT THE SWING
BUS AND CALCULATED FOR EACH BUS BASED ON THE XFRS TRUN RATIO.

21. WRITE THE LIGHTING FIXTURE NOMINAL VOLTAGE?


ANS: 91.7% TO 104.2