APPENDIX - I

FIG.1: Cross section of reinforced door opening (Type 2: as per BS 5649-7:1985, Pg.no: 12)

for pipes (ss) 310 N/mm2


for flats (ss) 250 N/mm2
Note :
For below calculations, Yeild stress considered is 250 N/mm2 ( Critical condition).
V = 528 mm
576 mm

L = (a-0.43N)

a= 1000 mm
N ( corner radius)= 113 mm
L= (1000-0.43*113)
951.41 mm

f6
= ((2∗ 〖 10 〗 ^5 ) ^2)/((2∗ 〖 10 〗 ^5 ) ^2+250 (951.41/528)2)

= 0.99

R= 784.5 mm
t= 6 mm
(ss)= 250 N/mm2
E = 2*105 N/mm2

=(𝑅∗√(s
r �/𝐸))/�

=(784.5∗√(250/
(2∗105)))/6
BENDING STRENGTH

MUX =(s�ɸ6�𝑝𝑛𝑟)/(1000∗𝑚)

ss = characterestic strength of material used for the column


or reinforcement, whichever is least (N/mm2)

ɸ6 factor having reinforcement type 1.

= ((𝐸) ^2)/((𝐸) ^2+s� (𝐿/𝑟)2)

ɸ1 = fig 1.

=(𝑅∗√(s
r �/𝐸))/�

Zpnr = 2R2t(2cos{[(q/2)-(90Bx/p)]-(sinq+Bxcosq)]}

=Bx
𝐴𝑒/𝑅� X 𝑀𝑢𝑥/𝑀𝑥

ɸ6 = 0.999

r = 4.51

Curve ɸ
f1= 0.81 - 0.24 (ɸ-1.9)0.9 for 2.41<p<=30
0.24

R= 784.5 mm
t= 6 mm
q = 15 deg
Mux = 812.45 mm
Mx = 818.7 mm
Ae = 27316.4952 mm2

Bx = 5.75

Zpnr = {2x784.52x6 (2 cos [(15/2)-(90x5.75)/p]-[(sin 15)+(5.75 cos15)]}


25486611.63 mm3

=(s
Mux�ɸ6�𝑝𝑛𝑟)/(1000∗𝑚)

=(250 x 0.24 x 25486611.63)/(1000 x 1.15)


=(250 x 0.24 x 25486611.63)/(1000 x 1.15)

1329736.259 N-m