SC202
SC202
2-Wire Conductivity Transmitter
The SC202,a two-wire electric conductivity transmitter with a microprocessor,
brings you the benefit of Yokogawa's extensive solution conductivity
measurement experience and state-of-the-art sensor technology.
Bulletin 12D08B02-E
www.yokogawa.com
The SC202 Meets Today's Demands for The convenience of linearized output
Advanced Conductivity / Resistivity Measurement Conductivity characteristics curves differ substantially for different solutions. In cases where
Flexibility, reliability and low maintenance are among the benefits provided by the EXA SC202 conductivity analyzer. the solution conductivity does not vary in direct proportion to concentration, the line-segment
Designed to meet the exacting requirements of measuring conductivity and resistivity in the modern industrial environment, linearized output function really works. The SC202 intelligent transmitter two-wire
it contains many features to ensure the best precision whatever the application. conductivity system can implement line-segment output linearization functions with 21 steps.
The SC202 meets the demanding ultrapure water requirements of the growing semiconductor and pharmaceutical markets This allows reliable measurement of conductivity at both high and low concentrations, fitting
in addition to traditional water quality measurements for standard power plant and chemical applications. in well with the properties of the measured liquid. This function is particularly useful in
Furthermore, the SC202 is useful as a concentration meter when liquid to be measured has a clear relationship between conductivity chemical, food processing, and pharmaceutical plants.
and concentration.
20 Example
Output (mA)
cases such as boiler startup, where there are
large differences between the conductivity at
12 startup and in normal operation.
Resistivity Measurement
The SC202 can also measure resistivity instead of conductivity. The combination of SC202
and SC4AJ (Conductivity detector) is recommended when high resistivity applications such as
ultrapure water are measured. Resistivity is measured by the kΩ·cm or MΩ·cm. For SC4AJ
information, refer to General Specifications (GS12D08G02-00E).
• On-line sensor checking issued in ed. 23 deter-mines a level of uncompensated conductivity for each Screw-in type Flow-through type 20~130V DC
or
temperature. The water must be below this level to be acceptable. This 80~138V AC,47~63Hz
curve is preprogrammed into the SC202 and is used in the setpoint
• Matrix temperature compensation calculations. or
for pure water applications General purpose
General purpose distributor
SDBT, SDBS
Conductivity limit as a function of Temperature according to USP<645> Flange type Screw-in type with Low-range type Analog output
• Password protection for all levels of software 3.5
gate valve Hazardous Non-hazardous
area area
1-5V DC
Conductivity detector Conductivity detector
SC210G SC4AJ
• Easy to use EXA control panel 3 Safety barrier
Conductivity (µS/cm)
2.5
• Pharmaceutical pure water monitoring Power
2
(USP<645> as issued in ed. 23.) 20~130V DC
or
1.5 80~138V AC,47~63Hz
Explosionproof
• Explosionproof type (SC202SJ)
1
0.5
0
0 20 40 60 80 100
Temperature (°C)
Specifications
• Input Specification • Transmission Signal
Two- or four-electrode measurement with cell constant from 0.008 to 50.0 4-20 mA DC Isolated output
cm-1 Conductivity or resistivity selective