Sei sulla pagina 1di 4

Nurse Call Series

Alert and Communication System

Clinics | Nursing Homes | Assisted Living Facilities


Features and Benefits
• Simple wiring
System is easy to install with simple
wiring, keeping installation costs low
• Simple operation
This easy-to-use system requires minimal
training, reducing the impact on staff
• Up to 80 patient stations
Patients or residents will have an efficient
way to communicate with staff
• Dedicated nurse master station
All incoming calls are controlled directly
from the nurse master station
• PTT or handset communication
Calls can be answered with push-to-talk
operation or with the handset for privacy
• LED and call tone indicators • Compact, attractive design
The urgency level of each call is indicated Users do not need to worry about desk clutter
by the LED lights and differentiating tones with this sleek, compact nurse master station
• Corridor and zone indicators • Spill-resistant cover on master
Staff can quickly see where a call is generated The protective membrane on the nurse
by using the corridor and zone indicator lights master station prolongs its lifespan
• Remote area duty station • Reliable and designed to last
Alerts staff of an incoming call when they Staff and patients/residents will have
are away from the nurse master station trouble‑free use for years to come

Ideal Applications - Clinics, Nursing Homes, Assisted Living Facilities

Save time and sustain Make sure personnel are Bedside call buttons ensure Along with bedside call
high-quality care with this never out of touch, even patients and residents have buttons, urgent call pull
communication system. in remote areas. With vital access to their nursing cords provide a way for
The master station is an the optional duty station, staff. With a simple push of patients or residents to
efficient way for caregivers nurses and staff will be the button, a routine call is instantly reach staff in an
to visualize and prioritize alerted of an incoming sent to the master station, emergency. The urgent
the urgency of multiple call while away from indicating assistance is call pull cord is ideal
calls, while providing the the master station. The needed. An unplugged cord for common bathroom
convenience of staff-to- differentiating call signal activates an urgent call at locations or in rooms
patient or staff-to-resident will indicate if the call is the master, indicating a where critical care is
communication. routine or urgent. serious situation. needed more often.
Nurse Stations Corridor Stations Patient/Resident Room Stations Bathroom Stations

Components
Control Unit, Power Nurse Master Station Duty Station
Supply, & Add‑On Card Install 1 per system Install 1 per system
Install 1 per system

PS‑2420UL (x2)
24V DC,
2A Power
Supply
NHR‑SP
NHX‑50M Duty Station
50‑Call Nurse • Ideal for break rooms,
Master Station hallways, or locations
NHX‑80X NHR‑30K • Priority level NHX‑30G without a master station
Central Control Unit 30‑Call Add‑On Trunk Card LED indicator 30‑Call Add‑On Selector • Alerts staff when a master
• Controls system functions (required for NHX‑30G) • Automatically connects (requires NHR‑30K) station receives a call
with microprocessor • Installs into NHX‑80X to next call in priority • Plugs into NHX‑50M • Urgent calls override
• Compact, slim design • Provides additional • Handset or push‑to‑talk with supplied connectors routine calls
capacity for NHX‑30G communication • Expands NHX‑50M to an • Tone off button
• Screwless wire connectors
Add‑On Selector • Desk or wall mount 80‑call master station • Flush mount
18-1/8" H 13‑3/8" W 3-7/8" D
8-1/4" H 8-1/4" H • Fits 2‑gang box
11" W 3-9/16" W 4-3/4" H
Indicator Light 3-3/4" D 2-5/16" D 4-9/16" W
Install up to 1-13/16" D
4 per system NHR‑3A‑4 Patient/Resident Stations
4‑Zone Call Indicator Light
(max. 4 ‑ requires 1 PS‑2420UL per 2)
Mix and match up to 80 total sub stations -
• Indicates the hallway/corridor
use call button(s), pull cord(s), and a corridor light per sub
where a call is made
• Wall or ceiling mount
4-3/4" H 17-5/8" W 1-7/8" D

NHR‑4A/A NHR‑3TS NHR‑7A


LED Corridor Light Dual Corridor Urgent Call
(red and amber LEDs) Light Sub Station Pull Cord
• Indicates the room (required for NHR‑7A if • Activates urgent
NH‑1SA/A NH‑2SA/A NHR‑8C where a call is made NH‑1SA/A or NH‑2SA/A call at master
• Amber light indicates a are not used)
Single‑Jack Dual‑Jack Bedside Call Button • Connects to
routine call and red light • Allows the urgent call sub stations for
Bedside Sub Bedside Sub (with 7' cord)
pull cord to be used
indicates an urgent call use in common
Station Station • Activates routine without the need for
call at master • Flush mount bathrooms
• One jack for • Two jacks for a bedside station (NHR‑3TS) or
bedside call bedside call • Cord‑out activates • Fits 1‑gang box
• Indicates where an urgent patient/resident
button buttons urgent call at master 4-3/4" H 2-3/4" W 1-1/2" D call has been made in a rooms (NH‑1SA/A
• Cancel button • Cancel button common area location or NH-2SA/A)
• Hands‑free • Hands‑free Use the urgent call pull • Stainless steel faceplate • Flush mount
communication communication cord for patient/resident • Flush mount • Fits 1‑gang box
• Flush mount • Flush mount rooms or bathrooms!
• Fits 2‑gang box 4-1/2" H
• Fits 2‑gang box • Fits 2‑gang box 4-3/4" H 2-13/16" W
4-3/4" H 4-3/4" H
NHR‑7A 1-3/4" D
Urgent Call Pull Cord 4-9/16" W
4-9/16" W 4-9/16" W (See details to the right →) 2-1/2" D
1-13/16" D 1-13/16" D

Specifications - UL 1069 Listed


NHX‑50M NH‑1SA/A
Spec▼ Model► NHX‑80X NHR‑8C NHR‑3TS NHR‑7A NHR‑4A/A NHR‑3A‑4
NHX‑30G NH‑2SA/A
NH‑1SA/A, NH‑2SA/A, NH‑1SA/A or PS‑2420UL
Power Source 2 PS‑2420ULs NHX‑80X NHX‑80X N/A NHX‑80X
or NHR‑3TS NH‑2SA/A (1 per 2 units)

Handset or
Communication N/A
push‑to‑talk
Hands-free N/A N/A N/A N/A N/A

Surface mount
Mounting with 3-gang
Desk mount 2-gang N/A 2-gang 1-gang 1-gang 5-gang

18AWG, 5 twisted
3-cond. to NH‑1SA/A, 3-cond. to NH‑1SA/A 5-cond. from
2-cond. from pairs from 4 twisted Plugs into 4 twisted
NH‑2SA/A, or NHR‑3TS or NH‑2SA/A NHX‑80X
Wire each PS‑2420UL NHX-80X pairs (Aiphone NH‑1SA/A or pairs (Aiphone
(Aiphone wire (Aiphone wire (Aiphone wire
(Aiphone wire (Aiphone wire wire #862208) NH‑2SA/A wire #862208)
#862208 or 822203) #862208 or 822203) #821803 x 2)
#821802) #862210)
Max. 16' to Max. 65' to Max. 330' per trunk Max. 330' per Max. 50' to NH‑1SA/A, Max. 50' to NH‑1SA/A Max. 165'
Wire Distance PS‑2420UL NHX‑80X line (cumulative)
N/A
trunk line NH‑2SA/A, or NHR‑3TS or NH‑2SA/A with 18AWG
Local Aiphone Experts are here to help.
CONTACT US TODAY!

Nurse Call ISO-14001 Certified ISO 9001:2008 Certified Deming Prize


(NHX Series)
Brochure
05/2013

UL 1069 Listed GS-35F-0065L Aiphone Co. Ltd. Aiphone Corp. Aiphone Co. Ltd.

1700 130th Ave NE · Bellevue, WA 98005 · T: (800) 692‑0200 · F: (425) 455‑0071 · www.aiphone.com

Potrebbero piacerti anche