BTS3900A & DBS3900

Hardware Description for Enhanced


Cabinets

Issue 01
Date 2013-04-28

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://www.huawei.com
Email: support@huawei.com

Issue 01 (2013-04-28) Huawei Proprietary and Confidential i


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900
Hardware Description for Enhanced Cabinets About This Document

About This Document

Overview
This document provides reference for planning and deploying a BTS3900A (Ver.D_A1),
DBS3900 (Ver.D_A1), BTS3900A (Ver.D_A2), and DBS3900 (Ver.D_A2). It describes the
configuration, functions, and specifications of components to be replaced during the hardware
upgrade of the BTS3900A (Ver.D_A1), DBS3900 (Ver.D_A1), BTS3900A (Ver.D_A2), and
DBS3900 (Ver.D_A2). It also presents the cable connections, connector specifications, and
connector installation positions after the upgrade.

Product Version
The following table lists the product versions related to this document.

Product Name Product Version

BTS3900A WCDMA and DBS3900 V200R013C00 and later versions


WCDMA

BTS3900A LTE and DBS3900 LTE V100R003C00 and later versions

BTS3900A GSM and DBS3900 GSM V100R013C00 and later versions

BTS3900A and DBS3900 V100R004C00 and later versions

Intended Audience
This document is intended for:
l System engineers
l Base station installation engineers
l Site maintenance engineers

Organization
1 Changes in BTS3900A&DBS3900 Hardware Description for Enhanced Cabinets

Issue 01 (2013-04-28) Huawei Proprietary and Confidential ii


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900
Hardware Description for Enhanced Cabinets About This Document

This chapter describes the changes in BTS3900A&DBS3900 Hardware Description for


Enhanced Cabinets.

2 Upgrade from APM30H (Ver.A) Series Cabinets to APM30H (Ver.D_A2) Series


Cabinets

APM30H (Ver.A) series cabinets consist of the APM30H, TMC11H, IBBS200T, and RFC. This
chapter describes the components replaced during the upgrade from APM30H (Ver.A) to
APM30H (Ver.D_A2), TMC11H (Ver.A) to TMC11H (Ver.D_A2), or IBBS200T (Ver.A) to
IBBS200T (Ver.D_A2). In addition, it describes the cables and cable connections in the
BTS3900A (Ver.D_A2) (shortened to BTS3900A in this document) and DBS3900 (Ver.D_A2)
(shortened to DBS3900 in this document).

3 Upgrade from APM30 Series Cabinets to APM30H (Ver.D_A1) Series Cabinets

APM30 series cabinets include the APM30, TMC, BBC, and RFC. This chapter describes the
components replaced during the upgrade of the APM30, TMC, and BBC. In addition, it describes
the cables and cable connections in the BTS3900A (Ver.D_A1) (shortened to BTS3900A in this
document) and DBS3900 (Ver.D_A1) (shortened to DBS3900 in this document).

Conventions
Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol Description

Indicates a hazard with a high level or medium level of risk


which, if not avoided, could result in death or serious injury.

Indicates a hazard with a low level of risk which, if not


avoided, could result in minor or moderate injury.

Indicates a potentially hazardous situation that, if not


avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.

Indicates a tip that may help you solve a problem or save


time.

Provides additional information to emphasize or supplement


important points of the main text.

General Conventions

The general conventions that may be found in this document are defined as follows.

Convention Description

Times New Roman Normal paragraphs are in Times New Roman.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential iii


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900
Hardware Description for Enhanced Cabinets About This Document

Convention Description

Boldface Names of files, directories, folders, and users are in


boldface. For example, log in as user root.

Italic Book titles are in italics.


Courier New Examples of information displayed on the screen are in
Courier New.

Command Conventions

The command conventions that may be found in this document are defined as follows.

Convention Description

Boldface The keywords of a command line are in boldface.

Italic Command arguments are in italics.

[] Items (keywords or arguments) in brackets [ ] are optional.

{ x | y | ... } Optional items are grouped in braces and separated by


vertical bars. One item is selected.

[ x | y | ... ] Optional items are grouped in brackets and separated by


vertical bars. One item is selected or no item is selected.

{ x | y | ... }* Optional items are grouped in braces and separated by


vertical bars. A minimum of one item or a maximum of all
items can be selected.

[ x | y | ... ]* Optional items are grouped in brackets and separated by


vertical bars. Several items or no item can be selected.

GUI Conventions

The GUI conventions that may be found in this document are defined as follows.

Convention Description

Boldface Buttons, menus, parameters, tabs, window, and dialog titles


are in boldface. For example, click OK.

> Multi-level menus are in boldface and separated by the ">"


signs. For example, choose File > Create > Folder.

Keyboard Operations

The keyboard operations that may be found in this document are defined as follows.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential iv


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900
Hardware Description for Enhanced Cabinets About This Document

Format Description

Key Press the key. For example, press Enter and press Tab.

Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl+Alt
+A means the three keys should be pressed concurrently.

Key 1, Key 2 Press the keys in turn. For example, pressing Alt, A means
the two keys should be pressed in turn.

Mouse Operations
The mouse operations that may be found in this document are defined as follows.

Action Description

Click Select and release the primary mouse button without moving
the pointer.

Double-click Press the primary mouse button twice continuously and


quickly without moving the pointer.

Drag Press and hold the primary mouse button and move the
pointer to a certain position.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential v


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900
Hardware Description for Enhanced Cabinets Contents

Contents

About This Document.....................................................................................................................ii


1 Changes in BTS3900A&DBS3900 Hardware Description for Enhanced Cabinets...........1
2 Upgrade from APM30H (Ver.A) Series Cabinets to APM30H (Ver.D_A2) Series Cabinets
..............................................................................................................................................................2
2.1 BTS3900A&DBS3900 Cabinets Interior...........................................................................................................4
2.2 APM30H Components to Be Replaced During the Upgrade...........................................................................11
2.2.1 Front Door...............................................................................................................................................12
2.2.2 Fan Assembly..........................................................................................................................................13
2.2.3 AC/DC Power System.............................................................................................................................17
2.3 TMC11H Components to Be Replaced During the Upgrade...........................................................................29
2.3.1 Front Door...............................................................................................................................................29
2.3.2 Fan Assembly..........................................................................................................................................30
2.3.3 DCDU-12B..............................................................................................................................................34
2.3.4 DCDU-12C..............................................................................................................................................39
2.4 RFC Components to Be Replaced During the Upgrade...................................................................................42
2.4.1 DCDU-13A..............................................................................................................................................42
2.4.2 CMUEA Assembly..................................................................................................................................44
2.4.3 Fan Assembly..........................................................................................................................................49
2.4.4 ELU Assembly........................................................................................................................................50
2.5 IBBS200T Components to Be Replaced During the Upgrade.........................................................................50
2.5.1 Power Distribution Box...........................................................................................................................50
2.6 Auxiliary Equipment........................................................................................................................................53
2.6.1 SLPU.......................................................................................................................................................53
2.6.2 OFD06.....................................................................................................................................................59
2.6.3 ODM06D-3..............................................................................................................................................61
2.7 BTS3900A&DBS3900 Cables.........................................................................................................................63
2.7.1 BTS3900A Cable List.............................................................................................................................63
2.7.2 DBS3900 Cable List................................................................................................................................68
2.7.3 Cable Connections...................................................................................................................................71
2.7.4 Equipotential Cable.................................................................................................................................81
2.7.5 Power Cables...........................................................................................................................................82
2.7.6 Signal Cables...........................................................................................................................................94

Issue 01 (2013-04-28) Huawei Proprietary and Confidential vi


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900
Hardware Description for Enhanced Cabinets Contents

3 Upgrade from APM30 Series Cabinets to APM30H (Ver.D_A1) Series Cabinets........104


3.1 BTS3900A&DBS3900 Cabinets Interior.......................................................................................................106
3.2 APM30 Components to Be Replaced During the Upgrade............................................................................114
3.2.1 Front Door.............................................................................................................................................115
3.2.2 Door Status Sensor................................................................................................................................116
3.2.3 Temperature Sensors.............................................................................................................................116
3.2.4 CMUEA Assembly................................................................................................................................117
3.2.5 Fan Assembly on the Top of the Cabinet Interior.................................................................................123
3.2.6 AC/DC Power System...........................................................................................................................124
3.3 TMC Components to Be Replaced During the Upgrade................................................................................137
3.3.1 Front Door.............................................................................................................................................137
3.3.2 Door Status Sensor................................................................................................................................138
3.3.3 Temperature Sensors.............................................................................................................................139
3.3.4 CMUEA Assembly................................................................................................................................140
3.3.5 Fan Assembly on the Top of the Cabinet Interior.................................................................................145
3.3.6 DCDU-12B............................................................................................................................................146
3.3.7 DCDU-12C............................................................................................................................................151
3.4 RFC Components to Be Replaced During the Upgrade.................................................................................155
3.4.1 DCDU-13A............................................................................................................................................155
3.4.2 CMUEA Assembly................................................................................................................................157
3.4.3 Fan Assembly........................................................................................................................................162
3.4.4 ELU Assembly......................................................................................................................................163
3.5 BBC Components to Be Replaced During the Upgrade.................................................................................163
3.6 Auxiliary Equipment......................................................................................................................................164
3.6.1 SLPU.....................................................................................................................................................165
3.6.2 OFD06...................................................................................................................................................171
3.6.3 ODM06D-3............................................................................................................................................173
3.7 BTS3900A&DBS3900 Cables.......................................................................................................................175
3.7.1 BTS3900A Cable List...........................................................................................................................175
3.7.2 DBS3900 Cable List..............................................................................................................................181
3.7.3 Cable Connections.................................................................................................................................185
3.7.4 Equipotential Cable...............................................................................................................................195
3.7.5 Power Cables.........................................................................................................................................195
3.7.6 Signal Cables.........................................................................................................................................207

Issue 01 (2013-04-28) Huawei Proprietary and Confidential vii


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 1 Changes in BTS3900A&DBS3900 Hardware Description
Hardware Description for Enhanced Cabinets for Enhanced Cabinets

1 Changes in BTS3900A&DBS3900 Hardware


Description for Enhanced Cabinets

This chapter describes the changes in BTS3900A&DBS3900 Hardware Description for


Enhanced Cabinets.

01 (2013-04-28)
This is the first official release.
Compared with issue Draft A (2012-12-30), no information is added or deleted from this issue.
Compared with issue Draft A (2012-12-30), this issue includes the following changes:
Changed the document name from BTS3900A&DBS3900 Post-Upgrade Hardware
Description to BTS3900A&DBS3900 Hardware Description for Enhanced Cabinets.

Draft A (2012-12-30)
This is a draft.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 1


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

2 Upgrade from APM30H (Ver.A) Series


Cabinets to APM30H (Ver.D_A2) Series
Cabinets

About This Chapter

APM30H (Ver.A) series cabinets consist of the APM30H, TMC11H, IBBS200T, and RFC. This
chapter describes the components replaced during the upgrade from APM30H (Ver.A) to
APM30H (Ver.D_A2), TMC11H (Ver.A) to TMC11H (Ver.D_A2), or IBBS200T (Ver.A) to
IBBS200T (Ver.D_A2). In addition, it describes the cables and cable connections in the
BTS3900A (Ver.D_A2) (shortened to BTS3900A in this document) and DBS3900 (Ver.D_A2)
(shortened to DBS3900 in this document).
2.1 BTS3900A&DBS3900 Cabinets Interior
To meet requirements in different outdoor environments, Huawei provides various cabinets for
the separated macro base station such as BTS3900A (Ver.D_A2) and distributed base station
such as DBS3900 (Ver.D_A2). The cabinets include the APM30H, TMC11H, RFC, and
IBBS200T, which provide different functions. The RFC is used only for the BTS3900A.
2.2 APM30H Components to Be Replaced During the Upgrade
During the APM30H hardware upgrade, the following components need to be replaced: the door
of the cabinet, fan assembly, and AC/DC power system.
2.3 TMC11H Components to Be Replaced During the Upgrade
During the TMC11H hardware upgrade, the following components need to be replaced: the door
of the cabinet, fan assembly, and AC/DC power system.
2.4 RFC Components to Be Replaced During the Upgrade
During the RFC hardware upgrade, the following components need to be replaced: the
DCDU-13A, CMUEA, and fan assembly.
2.5 IBBS200T Components to Be Replaced During the Upgrade
During the IBBS200T hardware upgrade, the power distribution box needs to be replaced.
2.6 Auxiliary Equipment
This section describes the auxiliary equipment to be replaced during the hardware upgrade from
APM30H (Ver.A) series cabinets to APM30H (Ver.D) series cabinets. The auxiliary equipment

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 2


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

includes the Signal Lightning Protection Unit (SLPU), Outdoor Fiber Distribution, 6 (OFD06),
Outdoor Distribution Module DC, 6 (ODM06D-3).
2.7 BTS3900A&DBS3900 Cables
This section describes the ground cables for the front door, power cables, and signal cables of
the BTS3900A and DBS3900. BTS3900A and DBS3900 transmission cables as well as
BTS3900A RF cables are reused during the upgrade, and therefore are not described in this
section.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 3


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

2.1 BTS3900A&DBS3900 Cabinets Interior


To meet requirements in different outdoor environments, Huawei provides various cabinets for
the separated macro base station such as BTS3900A (Ver.D_A2) and distributed base station
such as DBS3900 (Ver.D_A2). The cabinets include the APM30H, TMC11H, RFC, and
IBBS200T, which provide different functions. The RFC is used only for the BTS3900A.

APM30H interior
The following figure shows the APM30H interior.

Figure 2-1 APM30H interior

The following table describes the components in the APM30H.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 4


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-1 Components in the APM30H


N Compo Op Max Description
o. nent tio imu
nal m
or Qua
Ma ntit
nda y in
tor a
y Sin
gle
Cab
inet

1 Heat Ma 1 The heat exchanger core promotes the inner and outer air
exchang ndat circulation, and exchanges internal and external air. In this
er core ory way, it lowers the operating temperature of the cabinet and
protects the cabinet from dust.

2 Fan Ma 1 A fan assembly is configured with fans and a central


assembl ndat monitoring unit type EA (CMUEA), dissipating heat from the
y ory cabinet.

3 SLPU Ma 2 l To provide protection for trunk signals, a signal lightning


ndat protection unit (SLPU) is mandatory and installed in the
ory top 1 U space of the cabinet. It is configured with the
universal E1/T1 lightning protection unit (UELP) or
universal FE lightning protection unit (UFLP).
l To provide protection for monitoring signals, an SLPU is
optional and installed in the 1 U space below the BBU. It
is configured with two universal signal lightning
protection unit 2 (USLP2) boards.

4 ELU Ma 1 The electronic label unit (ELU) reports the cabinet type
ndat automatically to facilitate troubleshooting.
ory

5 Door Ma 1 It reports the door status, whether open or closed.


status ndat
sensor ory

6 EPU Ma 1 The Embedded Power subrack Unit (EPU) converts AC


ndat power into DC power and feeds power to the devices inside
ory the cabinet. The EPU consists of the EPU subrack, PMU, and
PSUs.

7 BBU390 Ma 2 The BBU3900 processes the baseband signals and enables


0 ndat the base station and the base station controller to interact.
ory

8 GATM Opt 2 The GSM Antenna and TMA Control module (GATM)
iona reports the RET control signal alarms.
l

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 5


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

N Compo Op Max Description


o. nent tio imu
nal m
or Qua
Ma ntit
nda y in
tor a
y Sin
gle
Cab
inet

9 EMUA Opt 1 An environment monitoring unit type A (EMUA) monitors


iona the environment in a cabinet and processes alarms.
l

10 AC Opt 1 The AC heater ensures that components in the cabinet work


heater iona within the acceptable temperature range when the
l surrounding temperature is low. It can be installed in the 1 U
space at the bottom of the cabinet. If both an AC heater and
an SOU are configured, the heater is installed in the 1 U space
above the SOU.

11 SOU Opt 1 The SOU can be installed in the 1 U space at the bottom of
iona the cabinet, transferring AC power supply to the customer
l equipment.

TMC11H Interior
There are two types of TMC11H:
l One type of TMC11H houses the BBU3900 and uses the -48 V DC power supply, as shown
in illustration A in the following figure.
l The other type of TMC11H houses only transmission equipment, as shown in illustration
B in the following figure.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 6


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-2 TMC11H interior

The following table describes the components in the TMC11H.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 7


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-2 Components in the TMC11H


N Compo Op Max Description
o. nent tio imu
nal m
or Qua
Ma ntity
nda in a
tor Sing
y le
Cabi
net

1 Heat Ma 1 The heat exchanger core promotes the inner and outer air
exchange ndat circulation, and exchanges internal and external air. In this
r core ory way, it lowers the operating temperature of the cabinet and
protects the cabinet from dust.

2 Fan Ma 1 A fan assembly is configured with fans and a central


assembly ndat monitoring unit type EA (CMUEA), dissipating heat from
ory the cabinet.

3 SLPU Ma 2 l To provide protection for trunk signals, an SLPU is


ndat mandatory and installed in the top 1 U space of the
ory cabinet. It is configured with the UELP or UFLP.
l To provide protection for monitoring signals, an SLPU
is optional and installed in the 1 U space below the BBU.
It is configured with two USLP2s.

4 ELU Ma 1 The electronic label unit (ELU) reports the cabinet type
ndat automatically to facilitate troubleshooting.
ory

5 Door Ma 1 It reports the door status, whether open or closed.


status ndat
sensor ory

6 DCDU Ma 1 The direct current distribution unit (DCDU) is 1 U high and


ndat it provides ten DC power outputs for components in the
ory TMC. The DCDU-12B is used for the DC-powered
distributed base stations. The DCDU-12C is used for the
DC-powered macro base stations and transmission cabinets.

7 BBU390 Ma 2 The BBU3900 processes the baseband signals and enables


0 ndat the base station and the base station controller to interact.
ory

8 EMUA Opt 1 An environment monitoring unit type A (EMUA) monitors


iona the environment in a cabinet and processes alarms. The
l EMUA must be configured when more than 16 Boolean
alarm inputs are required. It is installed in the 1 U space
below the BBU.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 8


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

N Compo Op Max Description


o. nent tio imu
nal m
or Qua
Ma ntity
nda in a
tor Sing
y le
Cabi
net

9 AC Opt 1 The AC heater ensures that components in the cabinet work


heater iona within the acceptable temperature range when the
l surrounding temperature is low. It can be installed in the 1
U space at the bottom of the cabinet.

RFC Interior
The Radio Frequency Cabinet (RFC) is used by the BTS3900A and provides installation space
for RFUs.
The following figure shows the RFC interior.

Figure 2-3 RFC interior

The following table describes the components in the RFC.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 9


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-3 Components in the RFC


No. Module/ Optional Maximum Description
Board or Quantity
Mandato in a Single
ry Cabinet

1 CMUEA Mandator 1 The Central Monitoring Unit type EA


assembly y (CMUEA) assembly consists of the support
and CMUEA.

2 DCDU-13 Mandator 2 The DCDU-13A is a direct current


A y distribution unit. It provides four 30 A and
-48 V DC power outputs.

3 ELU Mandator 1 The ELU assembly consists of a support


assembly y and an electronic label unit (ELU). The
ELU automatically reports the cabinet type.

4 Fan Mandator 2 A fan assembly dissipates heat from the


assembly y cabinet. It contains two standalone fans.

5 RFUs Mandator 6 Radio frequency units (RFUs) are used in


y macro base stations. They perform
modulation and demodulation of baseband
signals and RF signals, data processing,
power amplifying, and VSWR test.

IBBS200T Interior
The following figure shows the IBBS200T interior.

Figure 2-4 IBBS200T interior

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 10


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

The following table describes the components in the IBBS200T.

Table 2-4 Components in the IBBS200T

No. Module/ Optional Maximum Description


Board or Quantity
Mandato in a Single
ry Cabinet

1 TEC Mandator 1 The TEC cooler ensures the normal


y operation of the IBBS200T in high-
temperature areas and dissipates heat for
the storage batteries.

2 Transfer Mandator 1 It provides ports for alarms reported by the


terminal y door status sensor, TEC, temperature
for the sensor for storage batteries, and smoke
signal sensor.
cable

3 Power Mandator 1 The power distribution box is installed on


distributio y the lower inner right wall of the cabinet. It
n box transfers and distributes power to the fan or
TEC and storage batteries.

4 Transfer Mandator 1 It provides power input ports for the TEC.


terminal y
for the
input
power
cable for
the TEC

2.2 APM30H Components to Be Replaced During the


Upgrade
During the APM30H hardware upgrade, the following components need to be replaced: the door
of the cabinet, fan assembly, and AC/DC power system.

The following table describes the APM30H components to be replaced during the upgrade.

Table 2-5 APM30H components to be replaced during the upgrade

Before the Upgrade After the Upgrade

Front door of the cabinet (including Front door of the cabinet (including the heat
the heat exchanger core, door status exchanger core, door status sensor, and PGND cable
sensor, and PGND cable for the door) for the door)

Fan assembly (including the HPMI, Fan assembly (including the fan subrack and
inner air circulation fan, and HEUA) CMUEA)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 11


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Before the Upgrade After the Upgrade

PSU4890 (including the PSUs and EPU05 (including the PMU and PSUs)
PMU) and PDU

2.2.1 Front Door


The front door of the cabinet consists of the door frame, heat exchanger core, and magnet of the
door status sensor. These components have been assembled before delivery.
The following figure shows the structure of the front door.

Table 2-6 Components of the front door


No. Component Description

1 Heat exchanger core The heat exchanger core promotes the inner and outer
air circulation, and exchanges internal and external
air. In this way, it lowers the operating temperature of
the cabinet and protects the cabinet from dust.

2 Magnet of a door The door status sensor reports the door status.
status sensor It consists of a switch and a magnet. The switch is
located on an inner wall of the cabinet and will not be
removed during the upgrade. The magnet is located
on the front door (as shown in the preceding figure)
and will be removed with the door. A new magnet will
be delivered with a new door.

3 PGND cable for the -


front door

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 12


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

2.2.2 Fan Assembly


The fan assembly is configured with fans and central monitoring unit type EA (CMUEA),
dissipating heat from the cabinet.

Fan Assembly
A fan assembly consists of the fan subrack, fans, and central monitoring unit type EA (CMUEA).

Figure 2-5 shows the exterior of a fan assembly.

Figure 2-5 Exterior of a fan assembly

(1) Fan subrack (2) Fan (3) CMUEA

For details about the ports and indicators on the CMUEA, see Central Monitoring Unit Type
EA (CMUEA).

Central Monitoring Unit Type EA (CMUEA)


The central monitoring unit type EA (CMUEA) mainly monitors the fans, heater, and cabinet
temperature. The CMUEA can be used in an AMP30H, RFC, TMC11H, IBBS200D, or
IBBS200T.

Exterior
Figure 2-6 shows the exterior of a CMUEA.

Figure 2-6 Exterior of a CMUEA

Ports
Figure 2-7 shows the ports on a CMUEA.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 13


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-7 Ports on a CMUEA

Table 2-7 describes the ports on a CMUEA.

Table 2-7 Ports on a CMUEA


No Port Remarks
.

(1) TEMP2 Reserved port, connected to the temperature sensor

(2) WATER Connected to the water sensor

(3) IFAN4 Connected to the inner circulation fan for the cabinet

(4) IFAN3 Connected to the inner circulation fan for the cabinet

(5) IFAN2 Connected to the inner circulation fan for the cabinet

(6) IFAN1 Connected to the inner circulation fan for the cabinet

(7) TEC Connected to the TEC cooler to receive alarms related to the TEC cooler

(8) TEMP1 l In the RFC, this port is connected to the temperature sensor at the air
intake vent of the cabinet to receive temperature alarms.
l In the IBBS200D or IBBS200T, this port is connected to the
temperature sensor to receive battery temperature alarm signals.

(9) COM_OUT RS485 signal port. It communicates with lower-level cascading ports
and reports monitoring information.
l In the APM30H, this port is connected to the PMU.
l In the RFC, TMC11H, or IBBS200D/IBBS200T, this port is
connected to the lower-level CMUEA.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 14


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

No Port Remarks
.

(10 COM_IN RS485 signal port. It communicates with upper-level cascading ports
) and reports monitoring information.
l In the APM30H, this port is connected to the BBU.
l In the RFC or TMC11H, this port is connected to the BBU or an
upper-level CMUEA.
l In the IBBS200T, this port is connected to the PMU or upper-level
CMUEA.

(11 RUN Indicating the running status of the fans


) indicator

(12 ALM Indicating the alarm status of the fans


) indicator

(13 ELU Port connected to the ELU to report the cabinet type
)

(14 GATE Boolean signal port connected to the door status sensor
)

(15 IN0, IN1, Reserved Boolean signal port


) and IN2

(16 SMOKE Boolean signal port connected to the smoke sensor


)

(17 EFAN1 Connected to the outer circulation fan for the cabinet
)

(18 EFAN2 Connected to the outer circulation fan for the cabinet
)

(19 PWR Power input port providing DC power input for the board
)

Indicators
Table 2-8 describes the indicators on the CMUEA.

Table 2-8 Indicators on the CMUEA

Silkscr Color Status Meaning


een

RUN Green Blinking (on for 1s and The board is functional and communicating
off for 1s) with the BBU properly.

Blinking (on for 0.125s The board is functional but fails to


and off for 0.125s) communicate with the BBU or the board is
not registered.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 15


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Silkscr Color Status Meaning


een

Steady on The board is in the power-on self-check


status.

Steady off The board is faulty.

ALM Red Steady off No alarm has been reported.

Steady on Alarms are generated, and the board must be


replaced.

Blinking (on for 1s and An alarm is generated, and the alarm may be
off for 1s) caused by an associated board or port fault.
Therefore, you need to locate the fault before
determining whether to replace the board.

DIP Switch
On the CMUEA, there is a DIP switch J18, which is used to set the working mode of the CMUEA
according to the cabinet type. Figure 2-8 shows the position of a DIP switch on the CMUEA.

Figure 2-8 Position of a DIP switch on the CMUEA

In different types of cabinet, the DIP switch on the CMUEA is set in different ways, as shown
in Figure 2-9.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 16


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-9 DIP switch setting on the CMUEA in different cabinets

NOTE
The white boxes indicate the positions of all bits in the DIP switch.

2.2.3 AC/DC Power System


The AC/DC system converts 110 V/220 V AC power to -48 V DC.

Components in the AC/DC Power System


The AC/DC power system consists of the PMU 11A, PSUs (AC/D), and EPU subrack.

Figure 2-10 shows the components in the AC/DC power system.

Figure 2-10 Components in the AC/DC power system

(1) PMU 11A (2) PSUs (3) Filler panel (4) EPU subrack

Table 2-9 describes the modules in the AC/DC power system.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 17


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-9 Modules in the AC/DC power system


Module Remarks

PMU 11A It is installed in slot 0. For details about the


PMU 11A, see PMU.

PSU A minimum of two PSUs must be configured.


The PSUs must be installed in adjacent slots
in the sequence from slot 1 to slot 5. For
details about PSUs, see PSU (AC/DC).

Filler panel A maximum of five PSUs can be configured


in the APM30H. Filler panels must be
installed in vacant slots.

EPU subrack For details, see EPU subrack.

EPU subrack
The APM30H supports four types of EPU subracks, which are used in a distributed base station
and a separated macro base station with different AC inputs, respectively. The EPU subrack
houses the PMU and PSUs. It also distributes AC input power and DC output power.

Subrack Types
Table 2-10 lists the types and applications of EPU subracks in the AMP30H.

Table 2-10 EPU subrack


Type Remarks Application

It is a 5 U subrack, housing a
maximum of five R4850G2
EPU05A Separated macro base station with external 220
PSUs and one PMU. It
-02 V AC input
distributes large- and small-
capacity DC power.

It is a 5 U subrack, housing a
maximum of five R4850G2
EPU05A Distributed base station with external 220 V AC
PSUs and one PMU. It
-03 input
distributes large- and small-
capacity DC power.

It is a 5 U subrack, housing a
maximum of five R4850G2
EPU05A Separated macro base station with external 110
PSUs and one PMU. It
-04 V AC input
distributes large- and small-
capacity DC power.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 18


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Type Remarks Application

It is a 5 U subrack, housing a
maximum of five R4850G2
EPU05A Distributed base station with external 110 V AC
PSUs and one PMU. It
-05 input
distributes large- and small-
capacity DC power.

Exterior and Components


The EPU05A-03 and EPU05A-05 apply to a distributed base station. Figure 2-11 and Figure
2-12 show the exteriors of the EPU05A-03 and EPU05A-05, respectively.

Figure 2-11 Exterior of an EPU05A-03 subrack

(1) PSU (2) AC surge protector (3) PSU1/4 circuit breaker, (4) AC OUTPUT circuit
PSU2/5 circuit breaker, breaker
and PSU3 circuit breaker

(5) BAT circuit breaker (6) Circuit breaker for (7) Output port for the (8) RFC1 output port
RFC1 battery

(9) LOAD0 to LOAD8 (10) RRU0 to RRU5 (11) Spare fuse box (12) AC INPUT
output ports output ports

(13) AC OUTPUT (14) PMU (15) Short-circuiting bar(1) -

NOTE
(1) On an EPU subrack with 220 V AC single-phase input, a short-circuiting bar is installed on the AC
INPUT wiring terminal to connect the L1, L2, and L3 terminals. On an EPU subrack with 220 V AC three-
phase input, there is no short-circuiting bar on the AC INPUT wiring terminal.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 19


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-12 Exterior of an EPU05A-05 subrack

(1) PSU (2) AC surge protector (3) PSU circuit breaker (4) AC OUTPUT1/AC
OUTPUT2 circuit breaker

(5) BAT circuit breaker (6) Circuit breaker for (7) Output port for the (8) RFC1 output port
RFC1 battery

(9) LOAD0 to LOAD8 (10) RRU0 to RRU5 (11) Spare fuse box (12) AC INPUT
output ports output ports

(13) AC OUTPUT (14) PMU - -

The EPU05A-02 and EPU05A-04 apply to a separated macro base station. Figure 2-13 and
Figure 2-14 show the exteriors of the EPU05A-02 and EPU05A-04, respectively.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 20


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-13 EPU05A-02

(1) PSU (2) AC surge protector (3) PSU1/4 circuit breaker, (4) AC OUTPUT circuit
PSU2/5 circuit breaker, breaker
and PSU3 circuit breaker

(5) BAT circuit breaker (6) Circuit breaker for RFC1 (7) Circuit breaker for (8) Output port for the
RFC2 battery

(9) RFC1 output port (10) RFC2 output port (11) LOAD0 to LOAD8 (12) Spare fuse box
output ports

(13) AC INPUT (14) AC OUTPUT (15) PMU (16) Short-circuiting bar(1)

NOTE
(1) On an EPU subrack with 220 V AC single-phase input, a short-circuiting bar is installed on the AC
INPUT wiring terminal to connect the L1, L2, and L3 terminals. On an EPU subrack with 220 V AC three-
phase input, there is no short-circuiting bar on the AC INPUT wiring terminal.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 21


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-14 EPU05A-04

(1) PSU (2) AC surge protector (3) PSU circuit breaker (4) AC OUTPUT1/AC
OUTPUT2 circuit breaker

(5) BAT circuit breaker (6) Circuit breaker for (7) Circuit breaker for (8) Output port for the battery
RFC1 RFC2

(9) RFC1 output port (10) RFC2 output port (11) LOAD0 to LOAD8 (12) Spare fuse box
output ports

(13) AC INPUT (14) AC OUTPUT (15) PMU -

Functions
The EPU distributes AC and DC power.

l The EPU performs the following AC power distribution functions:


– Providing two AC outputs. One is used for the service outlet unit (SOU). The other one
is connected to the junction box on the left of the cabinet, and divided into four AC
power outputs, which are then provided for the heater or heating film.
– The AC surge protector reports AC input surge protection alarms.
l The EPU provides 17 or 12 DC outputs for a distributed base station or separated macro
base station.

Table 2-11 lists the DC power distribution functions of the EPU subrack of the APM30H in a
distributed base station.

Table 2-11 DC power distribution functions of the EPU subrack in a distributed base station

DC Power DC output Protector Protector Protector DC Output


Supply ports Specificati Quantity Ports
Unit on

BBU LOAD0 Fuse(1) 30 A 2 EPC4, EPC5,


and or EPC6
LOAD1

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 22


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

DC Power DC output Protector Protector Protector DC Output


Supply ports Specificati Quantity Ports
Unit on

Fan assembly LOAD2 1

TM_0 LOAD3 1

TM_1 LOAD4 1

TM_2 or LOAD5 1
EMUA

TM_3 or LOAD6 1
BBU

TMC LOAD7 1

IBBS LOAD8 1

RRU RRU0 to 6
RRU5

RFC RFC1 Breaker 125 A 1 OT terminal


(M6)

BAT BAT 250 A 1 OT terminal


(M8)

Table 2-12 lists the DC power distribution functions of the EPU subrack of the APM30H in a
separated macro base station.

Table 2-12 DC power distribution functions of the EPU subrack in a separated macro base station

DC Power DC output Protector Protector Protector DC Output


Supply ports Specificati Quantity Ports
Unit on

BBU LOAD0 and Fuse(2) 30 A 2 EPC4 or


LOAD1 EPC6

Fan LOAD2 1
assembly

TM_0 LOAD3 1

TM_1 LOAD4 1

TM_2 or LOAD5 1
EMUA

TM_3 or LOAD6 1
BBU

TMC LOAD7 1

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 23


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

DC Power DC output Protector Protector Protector DC Output


Supply ports Specificati Quantity Ports
Unit on

IBBS LOAD8 1

RFC1 RFC1 Breaker 125 A 1 OT terminal


(M6)

RFC2 RFC2 125 A 1 OT terminal


(M6)

BAT BAT 250 A 1 OT terminal


(M8)

NOTE
(1) and (2): The spare fuse box provides five 5 A fuses and three 30 A fuses, which can be replaced onsite.

Technical Specifications of an EPU Subrack


Table 2-13 lists the technical specifications of an EPU subrack.

Table 2-13 Technical specifications of an EPU subrack


Module Specifications

Output Voltage -58 V DC to -44 V DC

Rated Voltage -53.5 V DC

Output Current 0 A to 250 A

PMU
The power monitoring unit 11A (PMU 11A) provides the following functions: power system
management, battery management, power monitoring, and alarm reporting.

Exterior
Figure 2-15 shows the exterior of a PMU 11A.

Figure 2-15 Exterior of a PMU 11A

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 24


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Functions
The PMU 11A performs the following functions:

l Communicates with the upper-level device through an RS485 serial port.


l Manages the power system and charges and discharges storage batteries.
l Reports alarms related to the door status, standby Boolean values, and battery temperature.
l Monitors power distribution and reports alarms.
l Communicates with the battery cabinet through an RS485 serial port.

Ports
Figure 2-16 shows the ports on the front panel of the PMU 11A.

Figure 2-16 Ports on the front panel of the PMU 11A

Table 2-14 describes the ports on the front panel of the PMU 11A.

Table 2-14 Ports on the front panel of the PMU 11A

No. Silkscreen Connector Remarks

1 GATE 2-pin connector Connects to a door


status sensor

2 TEM_BAT 2-pin connector Monitors the battery


temperature sensor

3 COM_IN RJ45 connector BBU


communication port
which is connected to
the BBU or
communicates with
the upper-level
monitoring board

4 COM_OUT RJ45 connector Lower-level


monitoring board

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 25


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

No. Silkscreen Connector Remarks

5 COM_485 RJ45 connector Connects to the


monitoring board in
the battery cabinet,
and receives alarm
signals from the
battery cabinet.

Indicators
Table 2-15 describes the indicators on the PMU 11A.

Table 2-15 Indicators on the PMU 11A

Silks Colo Meaning Status Meaning


creen r

RUN Gree Running Steady on The PMU 11A is performing


n indicator startup, self-check, loading, and
activation.

Blinking (on for The PMU 11A is functional and


1s and off for 1s) communicating with the main
control board in the BBU properly.
(This status does not necessarily
mean that the PMU 11A has been
configured.)

Blinking (on for The PMU 11A is functional but


0.125s and off for unable to communicate properly.
0.125s)

Steady off The PMU 11A is faulty or there is


no DC power supply.

ALM Red Alarm indicator Steady on Alarms are generated, and the
module must be replaced.

Steady off No alarm is generated.

Blinking (on for An alarm is generated and you


1s and off for 1s) need to locate the fault before
determining whether to replace the
PMU 11A.

DIP Switch
There is a DIP switch on the left panel of the PMU 11A. The DIP switch has eight bits, where
the four least significant bits (1, 2, 3, and 4) define the monitoring address of the PMU 11A, and
the four most significant bits (5, 6, 7, and 8) are not defined but reserved for future use.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 26


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

ON is indicated by 1, and OFF is indicated by 0. The monitoring address of the PMU 11A is set
to 3 by default before delivery, as shown in Figure 2-17.

Figure 2-17 DIP switch on the left panel of the PMU 11A

NOTE

When two PMU 11As share the same RS485 bus in the case that two or more APM30Hs are configured
in a base station, the monitoring address of the second PMU 11A is set to 4, the four least significant bits
(1, 2, 3, and 4) set to be 0010.

PSU (AC/DC)
The power supply unit (PSU) converts 110 V AC or 220 V AC power into -48 V DC.

Exterior
Figure 2-18 shows the exterior of a PSU.

Figure 2-18 Exterior of a PSU

Functions
The PSU performs the following functions:

l Converts 110 V AC or 220 V AC power into -48 V DC. The PMU adjusts the output voltage.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 27


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

l The DC output of the PSU provides protection against overcurrent, overvoltage, and
overtemperature.
l Dissipates heat using its built-in fans.

Indicators
Figure 2-19 shows the indicators on the PSU panel.

Figure 2-19 Indicators on the PSU panel

(1) Power indicator (2) Protection indicator (3) Fault indicator

Table 2-16 describes the indicators on the PSU panel.

Table 2-16 Indicators on the PSU


Silkscr Color Status Meaning
een

Power Green Steady on The board is functional.


indicato
r Blinking (on for 0.125s PSU online loading
and off for 0.125s)

Steady off The mains supply or PSU is faulty.

Protecti Yellow Steady off Yes


on
indicato Steady on An alarm triggered by an external factor is
r generated.

Blinking (on for 1s and The communication between the PSU and the
off for 1s) PMU is interrupted.

Fault Red Steady off Yes


indicato
r Steady on The PSU is faulty or shut down in an
emergency. Locate the fault before
determining whether to replace the PSU.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 28


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

2.3 TMC11H Components to Be Replaced During the


Upgrade
During the TMC11H hardware upgrade, the following components need to be replaced: the door
of the cabinet, fan assembly, and AC/DC power system.

The following table describes the TMC11H components to be replaced during the upgrade.

Table 2-17 TMC11H components to be replaced during the upgrade

Before the Upgrade After the Upgrade

Front door of the cabinet (including Front door of the cabinet (including the heat
the heat exchanger core, door status exchanger core, door status sensor, and PGND cable
sensor, and PGND cable for the door) for the door)

Fan assembly (including the HPMI, Fan assembly (including the fan subrack and
inner air circulation fan, and HEUA) CMUEA)

DCDU-12B or DCDU-12C The DCDU-12C is used in the transmission cabinet


and DC-powered separated macro base station, and
the DCDU-12B is used in the DC-powered distributed
base station.

2.3.1 Front Door


The front door of the cabinet consists of the door frame, heat exchanger core, and magnet of the
door status sensor. These components have been assembled before delivery.

The following figure shows the structure of the front door.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 29


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-18 Components of the front door


No. Component Description

1 Heat exchanger core The heat exchanger core promotes the inner and outer
air circulation, and exchanges internal and external
air. In this way, it lowers the operating temperature of
the cabinet and protects the cabinet from dust.

2 Magnet of a door The door status sensor reports the door status.
status sensor It consists of a switch and a magnet. The switch is
located on an inner wall of the cabinet and will not be
removed during the upgrade. The magnet is located
on the front door (as shown in the preceding figure)
and will be removed with the door. A new magnet will
be delivered with a new door.

3 PGND cable for the -


front door

2.3.2 Fan Assembly


The fan assembly is configured with fans and central monitoring unit type EA (CMUEA),
dissipating heat from the cabinet.

Fan Assembly
A fan assembly consists of the fan subrack, fans, and central monitoring unit type EA (CMUEA).
Figure 2-20 shows the exterior of a fan assembly.

Figure 2-20 Exterior of a fan assembly

(1) Fan subrack (2) Fan (3) CMUEA

For details about the ports and indicators on the CMUEA, see Central Monitoring Unit Type
EA (CMUEA).

Central Monitoring Unit Type EA (CMUEA)


The central monitoring unit type EA (CMUEA) mainly monitors the fans, heater, and cabinet
temperature. The CMUEA can be used in an AMP30H, RFC, TMC11H, IBBS200D, or
IBBS200T.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 30


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Exterior
Figure 2-21 shows the exterior of a CMUEA.

Figure 2-21 Exterior of a CMUEA

Ports
Figure 2-22 shows the ports on a CMUEA.

Figure 2-22 Ports on a CMUEA

Table 2-19 describes the ports on a CMUEA.

Table 2-19 Ports on a CMUEA

No Port Remarks
.

(1) TEMP2 Reserved port, connected to the temperature sensor

(2) WATER Connected to the water sensor

(3) IFAN4 Connected to the inner circulation fan for the cabinet

(4) IFAN3 Connected to the inner circulation fan for the cabinet

(5) IFAN2 Connected to the inner circulation fan for the cabinet

(6) IFAN1 Connected to the inner circulation fan for the cabinet

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 31


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

No Port Remarks
.

(7) TEC Connected to the TEC cooler to receive alarms related to the TEC cooler

(8) TEMP1 l In the RFC, this port is connected to the temperature sensor at the air
intake vent of the cabinet to receive temperature alarms.
l In the IBBS200D or IBBS200T, this port is connected to the
temperature sensor to receive battery temperature alarm signals.

(9) COM_OUT RS485 signal port. It communicates with lower-level cascading ports
and reports monitoring information.
l In the APM30H, this port is connected to the PMU.
l In the RFC, TMC11H, or IBBS200D/IBBS200T, this port is
connected to the lower-level CMUEA.

(10 COM_IN RS485 signal port. It communicates with upper-level cascading ports
) and reports monitoring information.
l In the APM30H, this port is connected to the BBU.
l In the RFC or TMC11H, this port is connected to the BBU or an
upper-level CMUEA.
l In the IBBS200T, this port is connected to the PMU or upper-level
CMUEA.

(11 RUN Indicating the running status of the fans


) indicator

(12 ALM Indicating the alarm status of the fans


) indicator

(13 ELU Port connected to the ELU to report the cabinet type
)

(14 GATE Boolean signal port connected to the door status sensor
)

(15 IN0, IN1, Reserved Boolean signal port


) and IN2

(16 SMOKE Boolean signal port connected to the smoke sensor


)

(17 EFAN1 Connected to the outer circulation fan for the cabinet
)

(18 EFAN2 Connected to the outer circulation fan for the cabinet
)

(19 PWR Power input port providing DC power input for the board
)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 32


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Indicators
Table 2-20 describes the indicators on the CMUEA.

Table 2-20 Indicators on the CMUEA


Silkscr Color Status Meaning
een

RUN Green Blinking (on for 1s and The board is functional and communicating
off for 1s) with the BBU properly.

Blinking (on for 0.125s The board is functional but fails to


and off for 0.125s) communicate with the BBU or the board is
not registered.

Steady on The board is in the power-on self-check


status.

Steady off The board is faulty.

ALM Red Steady off No alarm has been reported.

Steady on Alarms are generated, and the board must be


replaced.

Blinking (on for 1s and An alarm is generated, and the alarm may be
off for 1s) caused by an associated board or port fault.
Therefore, you need to locate the fault before
determining whether to replace the board.

DIP Switch
On the CMUEA, there is a DIP switch J18, which is used to set the working mode of the CMUEA
according to the cabinet type. Figure 2-23 shows the position of a DIP switch on the CMUEA.

Figure 2-23 Position of a DIP switch on the CMUEA

In different types of cabinet, the DIP switch on the CMUEA is set in different ways, as shown
in Figure 2-24.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 33


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-24 DIP switch setting on the CMUEA in different cabinets

NOTE
The white boxes indicate the positions of all bits in the DIP switch.

2.3.3 DCDU-12B
A direct current distribution unit-12B (DCDU-12B) is 1 U high and provides DC power for all
components in the cabinet.

Exterior
Figure 2-25 and Figure 2-26 show exterior of a DCDU-12B.

Figure 2-25 Front view of a DCDU-12B

(1) DC input terminal (2) DC output terminal (3) Spare fuse box (4) Ground point

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 34


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-26 Rear view of a DCDU-12B

(1) Ground point

NOTE
The DCDU-12B uses the equipotential connection point and ground point in the following scenarios:
l Scenario 1: The DCDU-12B is installed on an open subrack. An equipotential cable connects the
equipotential connection point near the mounting ear of the DCDU-12B to the ground bar of the open
rack.
l Scenario 2: The DCDU-12B is installed on a wall as a standalone power distribution device. The ground
point at the rear of the DCDU-12B is connected to the ground bar in the cabinet.

Functions
The DCDU-12B provides ten -48 V DC outputs using same fuse configurations to meet the
power distribution requirements of different distributed base stations.

Table 2-21 describes the DC power distribution functions of the DCDU-12B.

Table 2-21 DC power distribution functions of the DCDU-12B

DCDU Type DC output Power- Specificatio Remarks


ports Consuming n of the
Device Fuse

DCDU-12B LOAD0 to RRU0 to RRU5 30 A l BTS3900


LOAD5 l BTS3900A
LOAD6 BBU or l DBS3900
transmission l Mini NodeB
device

LOAD7 BBU or
transmission
device

LOAD8 EMUA or
transmission
device

LOAD9 Fan assembly

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 35


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

NOTE
It is recommended that the power output terminals on the DCDU-12B be connected as follows:
l The LOAD0 to LOAD5 terminals are connected to cables with a cross-sectional area of 3.3mm2 (0.005
in.2) to 10mm2 (0.015 in.2) to provide power for RRU 0 to RRU 5.
l The LOAD6 to LOAD8 terminals are connected to cables with a cross-sectional area of 1.5mm2 (0.002
in.2) to 4mm2(0.006 in.2) to provide power for RRU 6 to RRU 8.
l The LOAD9 terminal is reserved.

Ports
Figure 2-27 shows the ports on the DCDU-12B panel.

Figure 2-27 Ports on the DCDU-12B panel

Table 2-22 shows the terminals and switches on the DCDU-12B panel.

Table 2-22 Terminals and switches on the DCDU-12B panel

N Port Silkscreen Matched Terminal Remarks


o. and Cable

(1) DC input NEG(-) One-hole OT Negative power input wiring


terminals terminal (M6) with terminal
two inputs. The
RTN(+) maximum cross- Positive power input wiring
sectional area of the terminal
cable is 35 mm2
(0.054 in.2) in one
input or 25 mm2
(0.039 in.2)in two
inputs. The default
cross-sectional area
is 16 mm2 (0.025 in.
2).

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 36


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

N Port Silkscreen Matched Terminal Remarks


o. and Cable

(2) Fuse LOAD0 to - It controls ports LOAD0 to


block LOAD9 LOAD9, and therefore controls
the power supplies to the BBU,
fan assemblies, and
transmission equipment.
The indicator on the fuse block
indicates the status of the fuse.
l When the indicator is steady
on, the fuse is faulty and
needs to be replaced.
l When the indicator is steady
off, the fuse is working
properly.

(3) DC LOAD0 to l Figure 2-28 For the specifications of the DC


output LOAD9 shows the EPC5 output, see Table 2-21.
ports connectors for
ports LOAD0 to
LOAD5. The
cross-sectional
area of the cable is
3.3mm2 (0.005 in.
2) to 10mm2

(0.015 in.2).
l Figure 2-29
shows an EPC4/
EPC6 connector,
which applies to
any one among
ports LOAD6 to
LOAD9. The
cross-sectional
area of the cable is
1.5mm2 (0.002 in.
2) to 4mm2(0.006

in.2).
NOTE
Figure 2-29 shows an
EPC4 or EPC6
connector. An EPC4
connector must be
connected to a cable
onsite, whereas an
EPC6 connector has
been connected to a
cable before delivery.
The EPC5 connector
must be connected to
the cable onsite.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 37


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

NOTE
Fuse blocks and DC output terminals are jointly called fuse terminal blocks.

Figure 2-28 Exterior of an EPC5 connector

Figure 2-29 Exterior of an EPC4 or EPC6 connector

Technical Specifications
Table 2-23 lists the technical specifications of a DCDU-12B.

Table 2-23 Technical specifications of a DCDU-12B


Item Specifications

Dimensions (H x W x D) The DCDU-12B is 1 U high and can be


installed in a 19-inch cabinet or rack. Its
dimensions are as follows:
l 42 mm x 442 mm x 65 mm (1.65 in. x 17.4
in. x 2.56 in.) (without mounting ears)
l 42 mm x 482.6 mm x 65 mm (1.65 in. x
19 in. x 2.56 in.) (with mounting ears)

Surge Protection Specifications -48 V DC power port, 10 kA (8/20 μs)


differential mode

-48 V DC power port, 20 kA (8/20 μs)


common mode

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 38


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

2.3.4 DCDU-12C
A direct current distribution unit-12C (DCDU-12C) is 1 U high and provides DC power input
for all components in the cabinet.

Exterior
Figure 2-30 shows the DCDU-12C.

Figure 2-30 Front view of a DCDU-12C

(1) DC input terminal (2) DC output terminal (3) Spare fuse box (4) Ground point

Functions
The DCDU-12C provides ten -48 V DC outputs using same fuse configurations to meet the
power distribution requirements of distributed and separated base stations

Table 2-24 describes the DC power distribution functions of a DCDU-12C.

Table 2-24 DC power distribution functions of a DCDU-12C

DCDU Type DC output Power- Specificatio Remarks


ports Consuming n of the
Device Fuse

DCDU-12C LOAD0 Transmission 30 A l BTS3900A (-48


device V)
l Transmission
LOAD1 Transmission
cabinet
device

LOAD2 Transmission
device

LOAD3 Transmission
device

LOAD4 Transmission
device

LOAD5 Transmission
device

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 39


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

DCDU Type DC output Power- Specificatio Remarks


ports Consuming n of the
Device Fuse

LOAD6 BBU or
transmission
device

LOAD7 BBU or
transmission
device

LOAD8 EMUA or
transmission
device

LOAD9 Fan assembly

Ports
Figure 2-31 shows the ports on the DCDU-12C panel.

Figure 2-31 Ports on the DCDU-12C panel

Table 2-25 describes the ports on the DCDU-12C panel.

Table 2-25 Ports on the DCDU-12C panel

N Port Silkscreen Matched Terminal Remarks


o. and Cable

(1) DC input NEG(-) Two one-hole OT Negative power input wiring


terminals terminals (M6). The terminal
cross-sectional area
of the cable is 25

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 40


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

N Port Silkscreen Matched Terminal Remarks


o. and Cable

RTN(+) mm2 (0.039) by Positive power input wiring


default. terminal

(2) Fuse LOAD0 to - It controls ports LOAD0 to


block LOAD9 LOAD9, and therefore controls
the power supplies to the BBU,
fan assemblies, and
transmission equipment.
The indicator on the fuse block
indicates the status of the fuse.
l When the indicator is steady
on, the fuse is faulty and
needs to be replaced.
l When the indicator is steady
off, the fuse is working
properly.

(3) DC LOAD0 to Figure 2-32 shows For the specifications of the DC


output LOAD9 an EPC4/EPC6 output, see Table 2-24.
ports connector, which
applies to any one
among ports LOAD0
to LOAD9. The
cross-sectional area
of the cable is
1.5mm2 (0.002 in.2)
to 4mm2(0.006 in.2).

NOTE
Fuse blocks and DC output terminals are jointly called fuse terminal blocks.

Figure 2-32 Exterior of an EPC4 or EPC6 connector

Technical Specifications
Table 2-26 lists the technical specifications of a DCDU-12C.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 41


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-26 Technical specifications of a DCDU-12C


Item Specifications

Dimensions (H x W x D) The DCDU-12C is 1 U high and can be


installed in a 19-inch cabinet or rack. Its
dimensions are as follows:
l 42 mm x 442 mm x 65 mm (1.65 in. x 17.4
in. x 2.56 in.) (without mounting ears)
l 42 mm x 482.6 mm x 65 mm (1.65 in. x
19 in. x 2.56 in.) (with mounting ears)

Surge Protection Specifications -48 V DC power port, 10 kA (8/20 μs)


differential mode

-48 V DC power port, 20 kA (8/20 μs)


common mode

2.4 RFC Components to Be Replaced During the Upgrade


During the RFC hardware upgrade, the following components need to be replaced: the
DCDU-13A, CMUEA, and fan assembly.
The following table describes the RFC components to be replaced during the upgrade.

Before the Upgrade After the Upgrade

DCDU-02 DCDU-13A

FMEA assembly (including a support CMUEA assembly (including a support and the
and the FMEA) CMUEA)

Fan assembly (including a case and Fan assembly (including a case and the fans)
the fans)

Filler panel ELU assembly (including a support and an ELU)

2.4.1 DCDU-13A
A direct current distribution unit-13A (DCDU-13A) is 1 U high and provides DC power for all
components in the cabinet.

Exterior
The following figure shows the exterior of a DCDU-13A.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 42


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-33 Exterior of a DCDU-13A

Function
The DCDU-13A has the following functions:
l Supports -48 V DC input.
l Provides four -48 V DC power outputs for other boards or modules in the cabinet.
l Provides surge protection of 10 kA in differential mode and 20 kA in common mode and
dry contacts for reporting the surge protection failure alarm.

Ports
The following figure shows the ports on the DCDU-13A panel.

Figure 2-34 Ports on the DCDU-13A panel

No. Port Silkscree Matched Terminal Description


n and Cable

1 Dry contact DC_SPD - Dry contact alarm


output port output port

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 43


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

No. Port Silkscree Matched Terminal Description


n and Cable

2 DC output ports LOAD0 to EPC4 connector (as l The LOAD0 to


LOAD3 shown in the LOAD3 ports on
following figure) the left
DCDU-13A in
the cabinet
provide power for
the CMUEA and
RFU 0 to RFU 2.
l The LOAD0 to
LOAD2 ports on
the right
DCDU-13A in
the cabinet
provide power for
RFU 3 to RFU 5.
The LOAD3 port
is reserved.

3 DC input NEG(-) Two one-hole OT It is a negative power


terminals terminals (M6). The input terminal.
maximum cross-
RTN(+) sectional area of the It is a positive power
single cable is 35 input terminal.
mm2 (0.054 in.2) and
each maximum cross-
sectional area of the
two pairs of cables is
16 mm2 (0.025 in.2).
The default cross-
sectional area is 25
mm2 (0.039 in.2).

Figure 2-35 EPC4 connector

2.4.2 CMUEA Assembly


The CMUEA assembly is a central monitoring unit. It is used for monitoring and reporting the
type of the cabinet.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 44


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

CMUEA Assembly
The CMUEA assembly consists of the CMUEA, ELU, and a support.

l The following figure shows the CMUEA components in the APM30 and TMC.

Figure 2-36 CMUEA components

(1) Central Monitoring Unit Type EA (CMUEA) (2)ELU

l The following figure shows the CMUEA components in the RFC.

Figure 2-37 CMUEA components

(1) Support (2) Central Monitoring Unit Type EA (CMUEA)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 45


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

For details about the ports and indicators on the CMUEA, see Central Monitoring Unit
Type EA (CMUEA).

Central Monitoring Unit Type EA (CMUEA)


The central monitoring unit type EA (CMUEA) mainly monitors the fans, heater, and cabinet
temperature. The CMUEA can be used in an AMP30H, RFC, TMC11H, IBBS200D, or
IBBS200T.

Exterior
Figure 2-38 shows the exterior of a CMUEA.

Figure 2-38 Exterior of a CMUEA

Ports
Figure 2-39 shows the ports on a CMUEA.

Figure 2-39 Ports on a CMUEA

Table 2-27 describes the ports on a CMUEA.

Table 2-27 Ports on a CMUEA


No Port Remarks
.

(1) TEMP2 Reserved port, connected to the temperature sensor

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 46


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

No Port Remarks
.

(2) WATER Connected to the water sensor

(3) IFAN4 Connected to the inner circulation fan for the cabinet

(4) IFAN3 Connected to the inner circulation fan for the cabinet

(5) IFAN2 Connected to the inner circulation fan for the cabinet

(6) IFAN1 Connected to the inner circulation fan for the cabinet

(7) TEC Connected to the TEC cooler to receive alarms related to the TEC cooler

(8) TEMP1 l In the RFC, this port is connected to the temperature sensor at the air
intake vent of the cabinet to receive temperature alarms.
l In the IBBS200D or IBBS200T, this port is connected to the
temperature sensor to receive battery temperature alarm signals.

(9) COM_OUT RS485 signal port. It communicates with lower-level cascading ports
and reports monitoring information.
l In the APM30H, this port is connected to the PMU.
l In the RFC, TMC11H, or IBBS200D/IBBS200T, this port is
connected to the lower-level CMUEA.

(10 COM_IN RS485 signal port. It communicates with upper-level cascading ports
) and reports monitoring information.
l In the APM30H, this port is connected to the BBU.
l In the RFC or TMC11H, this port is connected to the BBU or an
upper-level CMUEA.
l In the IBBS200T, this port is connected to the PMU or upper-level
CMUEA.

(11 RUN Indicating the running status of the fans


) indicator

(12 ALM Indicating the alarm status of the fans


) indicator

(13 ELU Port connected to the ELU to report the cabinet type
)

(14 GATE Boolean signal port connected to the door status sensor
)

(15 IN0, IN1, Reserved Boolean signal port


) and IN2

(16 SMOKE Boolean signal port connected to the smoke sensor


)

(17 EFAN1 Connected to the outer circulation fan for the cabinet
)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 47


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

No Port Remarks
.

(18 EFAN2 Connected to the outer circulation fan for the cabinet
)

(19 PWR Power input port providing DC power input for the board
)

Indicators
Table 2-28 describes the indicators on the CMUEA.

Table 2-28 Indicators on the CMUEA


Silkscr Color Status Meaning
een

RUN Green Blinking (on for 1s and The board is functional and communicating
off for 1s) with the BBU properly.

Blinking (on for 0.125s The board is functional but fails to


and off for 0.125s) communicate with the BBU or the board is
not registered.

Steady on The board is in the power-on self-check


status.

Steady off The board is faulty.

ALM Red Steady off No alarm has been reported.

Steady on Alarms are generated, and the board must be


replaced.

Blinking (on for 1s and An alarm is generated, and the alarm may be
off for 1s) caused by an associated board or port fault.
Therefore, you need to locate the fault before
determining whether to replace the board.

DIP Switch
On the CMUEA, there is a DIP switch J18, which is used to set the working mode of the CMUEA
according to the cabinet type. Figure 2-40 shows the position of a DIP switch on the CMUEA.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 48


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-40 Position of a DIP switch on the CMUEA

In different types of cabinet, the DIP switch on the CMUEA is set in different ways, as shown
in Figure 2-41.

Figure 2-41 DIP switch setting on the CMUEA in different cabinets

NOTE
The white boxes indicate the positions of all bits in the DIP switch.

2.4.3 Fan Assembly


A fan assembly dissipates heat from the cabinet. It contains two standalone fans.

Exterior
The following figure shows the structure of a fan assembly.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 49


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-42 Structure of the fan assembly

(1) Fans (2) Fan support

2.4.4 ELU Assembly


An ELU assembly consists of an electronic label unit (ELU) and an ELU support. The ELU
reports the cabinet type automatically to facilitate troubleshooting.

The following figure shows the structure of the ELU assembly.

Figure 2-43 ELU assembly

(1) ELU (2) Panel (3) RJ45 port

2.5 IBBS200T Components to Be Replaced During the


Upgrade
During the IBBS200T hardware upgrade, the power distribution box needs to be replaced.

2.5.1 Power Distribution Box


The power distribution box is installed on the lower side of the left inner wall of the cabinet,
which controls the two storage battery groups separately and the DC power supply to the fan or
TEC.

Exterior
The following figure shows the exterior of the power distribution box in the upgraded IBBS200T.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 50


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-44 Exterior of a power distribution box

Ports
The following table describes the ports and circuit breakers on a power distribution box.

No. Silkscreen on the Component Description


Panel

1 BAT Input power cable It supports a one-hole


port for storage OT terminal (M8)
batteries installed on a cable
with a cross-
sectional area of 35
mm2 (0.054 in.2).

2 BAT_SW0 Circuit breaker for It controls the power


the upper storage supply to upper
batteries storage batteries in
the cabinet. The
circuit breaker
requires 250 A
current.

3 FAN/ Power output port for It supports EPC4


TEC_OUTPUT the fan or TEC connectors and
requires 30 A
current.

4 BAT_SW1 Circuit breaker for It controls power


the lower storage supply to the lower
batteries storage batteries in
the cabinet. The
circuit breaker
requires 250 A
current.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 51


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

No. Silkscreen on the Component Description


Panel

5 BAT Input power cable It supports a one-hole


port for storage OT terminal (M8)
batteries installed on a cable
with a cross-
sectional area of 35
mm2 (0.054 in.2).

6 FAN/TEC_INPUT Power input port for It supports EPC4


the fan or TEC connectors and
requires 30 A
current.

Description
The following figure shows the cables for a power distribution box.

Figure 2-45 Cables for a power distribution box

(1) RTN(+) wire for the upper (2) Power transfer cable for a TEC (3) NEG(-) wire for the lower
storage batteries or fan storage batteries

(4) NEG(-) wire for the upper (5) RTN(+) wire for the lower -
storage batteries storage batteries

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 52


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

2.6 Auxiliary Equipment


This section describes the auxiliary equipment to be replaced during the hardware upgrade from
APM30H (Ver.A) series cabinets to APM30H (Ver.D) series cabinets. The auxiliary equipment
includes the Signal Lightning Protection Unit (SLPU), Outdoor Fiber Distribution, 6 (OFD06),
Outdoor Distribution Module DC, 6 (ODM06D-3).

2.6.1 SLPU
The signal lightning protection unit (SLPU), which can be optionally configured with the UFLP,
UELP, or USLP2, provides the signal surge protection.

SLPU
The SLPU, which has a case structure, is 19 inches wide and 1 U high.
Figure 2-46 shows the SLPU.

Figure 2-46 SLPU

Slot Assignment Rules for the SLPU


This section describes the slot assignment rules for the SPLU boards.

Slots of the SLPU


Figure 2-47 shows the slots of the SLPU.

Figure 2-47 SLPU slots

Slot Assignment Rules for the SLPU


When the SLPU is used as a trunk signal protection unit, a mandatory component, it can be
integrated with UELP or UFLP and is installed in the 1 U space in the upper part of the cabinet.
Table 2-29 lists the slot assignment rules of the SLPU.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 53


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-29 Slot assignment rules for the SLPU

Board Optional or Maximum Slot Remarks


Mandatory Quantity

UELP Optional 4 Slot 0 to slot 3 The UELP is


installed, in
descending
order of priority,
in slot 2, 0, 1, or
3.

UFLP Optional 1 Slot 3 If both the


UELP and
UFLP are
configured, the
UFLP is
installed in a slot
with a higher
priority than the
UELP.

When there are not more than 16 dry contacts in the SLPU, the SLPU is used as a monitoring
signal protection unit, which is an optional component. In this case, the SLPU is integrated with
two USLP2s and installed in the 1 U (44.45 mm or 1.75 in.) space at the bottom of the BBU.
Table 2-30 lists the slot assignment rules for the SLPU.

Table 2-30 Slot assignment rules for the SLPU

Board Optional or Quantity Slot Remarks


Mandatory

USLP2 Optional 2 Slot 2 and slot 3 -

UELP
Each universal E1/T1 lightning protection unit (UELP) provides surge protection for four paths
of E1/T1 signals.

Panel
Figure 2-48 shows the panel of the UELP.

Figure 2-48 UELP panel

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 54


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Ports
Table 2-31 lists the ports on the UELP.

Table 2-31 Ports on the UELP

Silkscreen Connector Description

INSIDE DB25 female connector Connecting to a transmission


board of the base station

OUTSIDE DB26 female connector Connecting to an external


transmission device

DIP Switch
The UELP has one DIP switch, which is used to determine whether the receiving end is grounded.
The DIP switch has four DIP bits. Figure 2-49 shows the DIP switch on the UELP.

Figure 2-49 DIP switch on the UELP

Table 2-32 describes the DIP switch on the UELP.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 55


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-32 DIP switch on the UELP

DIP DIP Status Description


Switch
1 2 3 4

S1 OFF OFF OFF OFF Not grounded

Other status Grounded

NOTE
The E1 cable of 75 ohms can be either grounded or not, whereas the E1 cable of 120 ohms and the T1 cable
of 100 ohms cannot be grounded.

UFLP
Each universal FE lightning protection unit (UFLP) provides protection for two channels of FE
signals. Each universal FE lightning protection unit type B (UFLPB) provides protection for two
channels of FE/GE signals.

NOTE
The UFLPB applies only to the LTE mode.

Panel
Figure 2-50 shows the UELP panel.

Figure 2-50 UELP panel

Figure 2-51 shows the UFLPB panel.

Figure 2-51 UFLPB panel

Port
Table 2-33 describes UFLP ports.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 56


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-33 UFLP ports

Port Location Silkscreen Connector Description

INSIDE side FE0 and FE1 RJ45 connector Connecting to a


transmission board of the
base station

OUTSIDE side FE0 and FE1 RJ45 connector Connecting to an external


transmission device

Table 2-34 describes UFLPB ports.

Table 2-34 UFLPB ports

Port Location Silkscreen on the Connector Description


Panel

INSIDE side FE/GE0 and FE/GE1 RJ45 connector Connecting to a


transmission board
of the base station

OUTSIDE side FE/GE0 and FE/GE1 RJ45 connector Connecting to an


external
transmission device

USLP2
The Universal Signal Lightning Protection Unit Type 2 (USLP2) is a dry contact surge protection
unit. It is optional and can be installed in the SLPU.

Panel
Figure 2-52 shows the panel of a USLP2.

Figure 2-52 Panel of a USLP2

Port
There are four input ports and two output ports on the USLP2. Table 2-35 lists the ports on the
panel of the USLP2.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 57


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-35 Ports on the panel of the USLP2

Silkscreen on Port Type Quantity Description


the Panel

IN0, IN1, IN2, 4-pin 4 Input ports, which


and IN3 connect to customized
alarm devices

OUT0 and OUT1 RJ45 connector 2 Output ports, which


connect to an EXT-
ALM port of the UPEU
or UEIU in the cabinet

Figure 2-53 shows the mapping relationship between the pins in the input and output ports on
the USLP2.

Figure 2-53 Mapping relationship between the pins in the input and output ports on the USLP2
OUT0 OUT1 IN0 IN1 IN2 IN3
7 5 3 1 7 5 3 1 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
8 6 4 2 8 6 4 2

Table 2-36 lists the mapping relationship between the pins in the input and output ports on the
USLP2.

Table 2-36 Mapping relationship between the pins in the input and output ports on the USLP2

Input Output

Silkscreen on the Pin Silkscreen on the Pin


Panel Panel

INO IN0.1 OUT1 OUT1.1

IN0.2 OUT1.2

IN0.3 OUT1.4

IN0.4 OUT1.5

IN1 IN1.1 OUT1.3

IN1.2 OUT1.6

IN1.3 OUT1.7

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 58


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Input Output

Silkscreen on the Pin Silkscreen on the Pin


Panel Panel

IN1.4 OUT1.8

IN2 IN2.1 OUT0 OUT0.1

IN2.2 OUT0.2

IN2.3 OUT0.4

IN2.4 OUT0.5

IN3 IN3.1 OUT0.3

IN3.2 OUT0.6

IN3.3 OUT0.7

IN3.4 OUT0.8

For details about the application of the USLP2, see Slot Assignment Rules for the SLPU.

2.6.2 OFD06
The Outdoor Fiber Distribution 6 (OFD06) distributes fiber optic cables on the RRU side.

Exterior
The following figure shows the OFD06 exterior.

Figure 2-54 OFD06 exterior

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 59


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Function
The OFD06 performs the following functions:
l Distributes fiber optic cables on the RRU side.
l Can be installed flexibly. The OFD06 can be installed on an outdoor wall, metal pole and
tower.

Interior
The following figure shows the OFD06 interior.

Figure 2-55 OFD06 interior

(1) Box (2) Optical fiber distribution and (3) Optical fiber routed-in area
storage area

(4) Fiber optic cables (connected to the (5) (6) Outdoor fiber optic jumpers
Indoor Fiber Distribution) (connected to RRUs)

Specifications
The following table lists the OFD06 specifications.

Table 2-37 OFD06 specifications

Item Specifications

Dimensions (H x W x D) 270 mm x 278 mm x 100 mm (10.63 in. x


10.94 in. x 3.94 in.)

Weight 2.5 kg (5.51 lb)

Operating temperature -40°C to 55°C (-40°F to 131°F)

Storage temperature -50ºC to 70ºC (-58°F to 158°F)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 60


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Item Specifications

Relative humidity ≤ 95%

Operating environment Outdoor

IP level IP65

INPUT (core) 1x12 cores

OUTPUT (core) 6x2 cores (connected to six RRUs)

Adapter DLC

Mounted type Pole or wall

Maintenance Front maintenance

Insert loss ≤ 0.3 dB

Return loss ≥ 45 dB

Fireproof level UL94 V0

2.6.3 ODM06D-3
The Outdoor Distribution Module DC 6 (ODM06D-3) performs functions such as power
distribution and surge protection. It provides surge protection for outdoor RRUs.

Exterior
The following figure shows the ODM06D-3 exterior.

Figure 2-56 ODM06D-3 exterior

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 61


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Function
The ODM06D-3 performs the following functions:
l Provides surge protection for outdoor RRUs.
l Provides one or two power inputs and six power outputs.
l Reports the surge protection failure alarm.

Interior
The following figure shows the ODM06D-3 interior.

Figure 2-57 ODM06D-3 interior

(1) Cover plate of the housing (2) Cable connector making label (3) Protective cover (4) Circuit breakers

(5) Surge protector (6) Cord end terminal bar (7) Clip

Specifications
The following table lists the specifications of the ODM06D-3.

Table 2-38 Specifications

Item Specification

Dimensions (H x W x D) 369 mm x 278.5 mm x 98.5 mm (14.53 in. x


10.96 in. x 3.88 in.)

Weight 4.0 kg (8.82 lb)

Color Light Gray RAL 7035 white

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 62


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Item Specification

Power inputs and outputs One or two inputs and six outputs

Safety IEC/EN60950-1 and IEC/EN60950-22

IP level IP65

Certification CE

Mounted type Pole and wall

Lightning protection alarm Dry connector

Operating temperature -40°C to 55°C (-40ºF to 131ºF)

Storage temperature -40ºC to +70ºC (-40ºF to +158ºF)

Relative humidity ≤ 95%

DC input connection -48 V and RTN (cord end terminal)

Input voltage range -48 V DC normal (-57 V DC to -36 V DC)

Maximum input current 100 A

Diameter range of input power cables 18 mm to 25 mm (0.71 in. to 0.98 in.)

DC output connection -48 V and RTN (cord end terminal)

Rated current 32 A

Output power distribution Six outputs connected to RRUs

Output power cable grounding Six grounded outputs

Diameter range of output power cables 9 mm to 14 mm (0.35 in. to 0.55 in.)

2.7 BTS3900A&DBS3900 Cables


This section describes the ground cables for the front door, power cables, and signal cables of
the BTS3900A and DBS3900. BTS3900A and DBS3900 transmission cables as well as
BTS3900A RF cables are reused during the upgrade, and therefore are not described in this
section.

2.7.1 BTS3900A Cable List


BTS3900A cables consist of the PGND cables, power cables, and signal cables.

Power Cables and PGND Cables


NOTE
Transmission cables in the BTS3900A need to be reused and the reused transmission cables are connected
to the original positions. For details about transmission cable connections in the BTS3900A, see BTS3900A
(Ver.A) GSM Hardware Description (with a Heat Exchanger).

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 63


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

The following table describes the power cables and PGND cables after the hardware upgrade.

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Equipotential OT terminal l Ground OT terminal l Front door of


Cable for the point on an the
Front Door inner wall of APM30H
the l Front door of
APM30H the
l Ground TMC11H
point on an
inner wall of
the
TMC11H

Input Power OT terminal AC INPUT Depending on External power


Cables for the terminal on the the external equipment
APM30H EPU in the power
APM30H equipment

Input Power EPC4 connector LOAD7 port on OT terminal RTN(+) and


Cable for the the EPU in the NEG(-)
TMC11H (in APM30H terminals on the
AC Scenarios) DCDU-12C in
the TMC11H

Input Power Depending on External power OT terminal RTN(+) and


Cable for the the external equipment NEG(-)
TMC11H (in power terminals on the
DC Scenarios) equipment DCDU-12C in
the TMC11H

Input Power OT terminal RFC1 terminal OT terminal RTN(+) and


Cable for the on the EPU in NEG(-)
RFC (in AC the APM30H terminals on the
Scenarios) left DCDU-13A
in the RFC

Input Power OT terminal RTN(+) and Depending on External power


Cable for the NEG(-) the external equipment
RFC (in DC terminals on the power
Scenarios) left DCDU-13A equipment
in the RFC

RFU Power EPC4 connector LOAD0 to 3V3 connector PWR port on


Cables LOAD2 ports any of RFU0 to
on the left RFU2 in the
DCDU-13A in RFC
the RFC

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 64


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

LOAD0 to PWR port on


LOAD2 ports any of RFU3 to
on the right RFU5 in the
DCDU-13A in RFC
the RFC

Power cables OT terminal l NEG(-) OT terminal l NEG(-)


between terminal on terminal on
cascaded the left the right
DCDU-13As DCDU-13A DCDU-13A
in the RFC in the RFC
l RTN(+) l RTN(+)
terminal on terminal on
the left the right
DCDU-13A DCDU-13A
in the RFC in the RFC

Power Cables OT terminal BAT terminal OT terminal RTN(+) and


for the Battery on the EPU in (M8) NEG(-)
Cabinet the APM30H terminals near
the BAT
silkscreen on the
power
distribution box
in the
IBBS200T

TEC Power EPC4 connector LOAD8 port on EPC4 connector FAN/


Cable the EPU in the TEC_INPUT
APM30H port on the
power
distribution box
in the
IBBS200T

BBU Power EPC4 connector LOAD0 and 3V3 connector -48V port on the
Cable (in AC LOAD1 ports UPEU in the
Scenarios) on the EPU in BBU in the
the APM30H APM30H or
TMC11H

BBU Power EPC4 connector LOAD6 and 3V3 connector -48V port on the
Cable (in DC LOAD7 ports UPEU in the
Scenarios) on the BBU in the
DCDU-12C in TMC11H
the TMC11H

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 65


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

CMUEA EPC4 connector LOAD2 port on 3V3 connector PWR port on the
Power Cable the EPU in the CMUEA in the
APM30H APM30H

LOAD9 port on PWR port on the


the DCDU-12C CMUEA in the
in the TMC11H TMC11H

LOAD3 port on PWR port on the


the left CMUEA in the
DCDU-13A in RFC
the RFC

EMUA Power EPC4 connector LOAD5 port on Cord end PWR1 terminal
Cable the EPU in the terminal on the EMUA
(Optional) APM30H

LOAD8 port on
the DCDU-12C
in the TMC11H

Signal Cables
The following table describes the signal cables after the hardware upgrade.

Cable One End The Other End

Connector Installation Connector Installation


Position Position

CMUEA-BBU RJ45 connector COM_IN port RJ45 connector MON1 port on


Monitoring on the CMUEA the UPEU in the
Signal Cable in the APM30H BBU in the
APM30H

COM_IN port MON0 port on


on the CMUEA the UPEU in the
in the RFC BBU in the
APM30H

Monitoring Bare wire Door status 2-pin connector GATE port on


Signal Cable for sensor the PMU in the
the Door Status APM30H
Sensor in the
APM30H

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 66


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Monitoring OT terminal Signal cable RJ45 connector COM_485 port


Signal Cable transfer on the CMUEA
for the terminal in the or PMU
IBBS200T IBBS200T

ELU Signal RJ45 connector ELU port on the RJ45 connector ELU
Cable CMUEA

Monitoring Bare wire l GATE port Bare wire Door status


Signal Cable on the sensor
for the Door CMUEA in
Status Sensor the
TMC11H
l GATE port
on the
CMUEA in
the RFC

Monitoring Interconnection l Power cable 4-pin connector l FAN_EXT


Signal Transfer terminal for the fan in port on the
Cable for the the front fan assembly
Fan in the Front door of the in the
Door APM30H APM30H
l Power cable l FAN_EXT
for the fan in port on the
the front fan assembly
door of the in the
TMC11H TMC11H

Surge Bare wire l DC_SPD Bare wire l IN0 port on


Protection port on the the CMUEA
Alarm Cable left in the RFC
for the DCDU-13A l IN1 port on
DCDU-13A in the RFC the CMUEA
l DC_SPD in the RFC
port on the
right
DCDU-13A
in the RFC

Monitoring 4-pin connector TEMP1 port on 5-pin connector Port on the


Signal Cable the CMUEA in environmental
for the the RFC temperature
Temperature sensor in the
Sensor RFC

PMU-CMUEA RJ45 connector COM_IN port RJ45 connector COM_OUT


Monitoring on the PMU port on the
Signal Cable CMUEA

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 67


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Monitoring RJ45 connector COM_OUT RJ45 connector COM_IN port


Signal Cable port on the on the lower-
Between upper-level level CMUEA
Cascaded CMUEA
CMUEAs

EMUA DB9 male RS485 port on RJ45 connector COM_OUT


Monitoring connector the EMUA in port on the PMU
Signal Cable the APM30H in the APM30H
(Optional)
RS485 port on COM_OUT
the EMUA in port on the
the TMC11H CMUEA in the
TMC11H

RF Cables
The following table describes the RF cables after the hardware upgrade.

NOTE

l When a Bias Tee is configured, the jumpers use DIN straight male connectors. After the cabinet is
upgraded, the Bias Tee needs to be removed, and therefore the DIN straight male connectors need to
be replaced by DIN elbow male connectors.
l When a Bias Tee is not configured before the upgrade, the original jumpers can be reused during the
upgrade.

Cable One End The Other End

Connector Installation Connector Installation


Position Position

RF jumpers DIN straight Antenna feeder DIN elbow male ANT_RXA and
male connector connector ANT_RXB
ports on RFUs

2.7.2 DBS3900 Cable List


DBS3900 cables consist of the PGND cables, power cables, and signal cables.

Power Cables and PGND Cables


NOTE
Transmission cables in the DBS3900 need to be reused and the reused transmission cables are connected
to the original positions. For details about transmission cable connections in the DBS3900, see DBS3900
Hardware Description.

The following table describes the power cables and PGND cables after the hardware upgrade.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 68


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Equipotential OT terminal l Ground OT terminal l Front door of


Cable for the point on an the
Front Door inner wall of APM30H
the l Front door of
APM30H the
l Ground TMC11H
point on an
inner wall of
the
TMC11H

Input Power OT terminal AC INPUT Depending on External power


Cables for the terminal on the the external equipment
APM30H EPU in the power
APM30H equipment

Input Power EPC4 connector LOAD7 port on OT terminal RTN(+) and


Cable for the the EPU in the NEG(-)
TMC11H (in APM30H terminals on the
AC Scenarios) DCDU-12C in
the TMC11H

Input Power Depending on External power OT terminal RTN(+) and


Cable for the the external equipment NEG(-)
TMC11H (in power terminals on the
DC Scenarios) equipment DCDU-12B in
the TMC11H

Power Cables OT terminal BAT terminal OT terminal RTN(+) and


for the Battery on the EPU in (M8) NEG(-)
Cabinet the APM30H terminals near
the BAT
silkscreen on the
power
distribution box
in the
IBBS200T

TEC Power EPC4 connector LOAD8 port on EPC4 connector FAN/


Cable the EPU in the TEC_INPUT
APM30H port on the
power
distribution box
in the
IBBS200T

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 69


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

BBU Power EPC4 connector LOAD0 and 3V3 connector -48V port on the
Cable (in AC LOAD1 ports UPEU in the
Scenarios) on the EPU in BBU in the
the APM30H APM30H or
TMC11H

BBU Power EPC4 connector LOAD6 and 3V3 connector -48V port on the
Cable (in DC LOAD7 ports UPEU in the
Scenarios) on the BBU in the
DCDU-12C in TMC11H
the TMC11H

CMUEA EPC4 connector LOAD2 port on 3V3 connector PWR port on the
Power Cable the EPU in the CMUEA in the
APM30H APM30H

LOAD9 port on PWR port on the


the DCDU-12C CMUEA in the
in the TMC11H TMC11H

EMUA Power EPC4 connector LOAD5 port on Cord end PWR1 terminal
Cable the EPU in the terminal on the EMUA
(Optional) APM30H

LOAD8 port on
the DCDU-12C
in the TMC11H

Signal Cables
The following table describes the signal cables after the hardware upgrade.

Cable One End The Other End

Connector Installation Connector Installation


Position Position

CMUEA-BBU RJ45 connector COM_IN port RJ45 connector MON1 port on


Monitoring on the CMUEA the UPEU in the
Signal Cable in the APM30H BBU in the
APM30H

Monitoring Bare wire Door status 2-pin connector GATE port on


Signal Cable for sensor the PMU in the
the Door Status APM30H
Sensor in the
APM30H

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 70


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Monitoring OT terminal Signal cable RJ45 connector COM_485 port


Signal Cable transfer on the CMUEA
for the terminal in the or PMU
IBBS200T IBBS200T

ELU Signal RJ45 connector ELU port on the RJ45 connector ELU
Cable CMUEA

Monitoring Bare wire GATE port on Bare wire Door status


Signal Cable the CMUEA in sensor
for the Door the TMC11H
Status Sensor

Monitoring Interconnection l Power cable 4-pin connector l FAN_EXT


Signal Transfer terminal for the fan in port on the
Cable for the the front fan assembly
Fan in the Front door of the in the
Door APM30H APM30H
l Power cable l FAN_EXT
for the fan in port on the
the front fan assembly
door of the in the
TMC11H TMC11H

PMU-CMUEA RJ45 connector COM_IN port RJ45 connector COM_OUT


Monitoring on the PMU port on the
Signal Cable CMUEA

Monitoring RJ45 connector COM_OUT RJ45 connector COM_IN port


Signal Cable port on the on the lower-
Between upper-level level CMUEA
Cascaded CMUEA
CMUEAs

EMUA DB9 male RS485 port on RJ45 connector COM_OUT


Monitoring connector the EMUA in port on the PMU
Signal Cable the APM30H in the APM30H
(Optional)
RS485 port on COM_OUT
the EMUA in port on the
the TMC11H CMUEA in the
TMC11H

2.7.3 Cable Connections


The power cable connections and signal cable connections in the BTS3900A (Ver.D_A2) and
DBS3900 (Ver.D_A2) vary according to the power supply scenarios, cabinet configurations,
and transmission system.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 71


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Power Cable Connections in a BTS3900A


This section describes the power cable connections in a BTS3900A supplied with 110 V AC,
220 V AC, and -48 V DC power to facilitate power cable installation and maintenance.

Power Cable Connections in a 110 V AC or 220 V AC Input Scenario


NOTE
If a device is not configured, ignore the power cable connections for the device in the figures showing
power cable connections.

When a BTS3900A is supplied with 110 V AC or 220 V AC power, 1 APM30H+1 TMC11H


+1 IBBS200T+2 RFCs are configured. The following figure shows the power cable connections.

Figure 2-58 Power cable connections in a base station configured with 1 APM30H+1 TMC11H
+1 IBBS200T+2 RFCs

The following table describes the power cable connections.

Table 2-39 Power cable connections in a base station configured with 1 APM30H+1 TMC11H
+1 IBBS200T+2 RFCs

No. Description

P0 Input power cable for the transfer terminal

P1 Input power cable for the APM30H

P2 and P9 CMUEA power cables

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 72


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

No. Description

P3 and P16 to P18 Power cables for the battery cabinet

P4 Input power cable for the RFC

P5 BBU power cable

P6 EMUA power cable

P7 Input power cable for the TMC11H

P8 Power cable between cascaded


DCDU-13As

P10 to P15 RFU power cables

Power Cable Connections in a -48 V DC Input Scenario


The following figure shows the power cable connections in a BTS3900A configured with 1
TMC11H+2 RFCs in a -48 V DC input scenario.

Figure 2-59 Power cable connections in a base station configured with 1 TMC11H+2 RFCs

The following table describes the power cable connections.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 73


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-40 Power cable connections in a base station configured with 1 TMC11H+2 RFCs
No. Description

P0 Input power cable for the TMC11H

P1 and P5 CMUEA power cables

P2 BBU power cable

P3 EMUA power cable

P4 Input power cable for the RFC

P6 to P11 RFU power cables

Monitoring Signal Cable Connections in a BTS3900A


This section describes the monitoring signal cable connections in a BTS3900A in 110 V or 220
V AC and -48 V DC scenarios.

Monitoring Signal Cable Connections in the 110 V or 220 V AC Scenario


NOTE
If a component is not configured, ignore the monitoring signal cable connections for the component in the
figures.

When a BTS3900A is in the configuration of 1 APM30H+1 TMC11H+1 IBBS200T+2 RFCs


and is supplied with 110 V or 220 V AC power, the monitoring signal cable connections are
shown in the following figure.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 74


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-60 Monitoring signal cable connections in the configuration of 1 APM30H+1


TMC11H+1 IBBS200T+2 RFCs

The following table describes the monitoring signal cable connections.

Table 2-41 Monitoring signal cable connections in the configuration of 1 APM30H+1 TMC11H
+1 IBBS200T+2 RFCs

No. Description

S1 Monitoring Signal Cable for the IBBS200T

S2 PMU-CMUEA Monitoring Signal Cable

S3 Monitoring Signal Cable for the EMUA

S4 Monitoring Signal Transfer Cable for the Fan


on the Front Door

S5 Monitoring Signal Cables for a Door Status


Sensor in an APM30H

S6 and S14 ELU Signal Cable

S7 and S8 CMUEA-BBU Monitoring Signal Cable

S9 and S17 Monitoring Signal Cable Between Cascaded


CMUEAs

S10 and S16 Monitoring Signal Cable for the Fan


Assembly in the RFC

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 75


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

No. Description

S11 and S12 Surge Protection Alarm Cable for the


DCDU-13A

S13, S18, and S19 Monitoring Signal Cable for the Door Status
Sensor

S15 Monitoring Signal Cable for the


Temperature Sensor

Monitoring Signal Cable Connections in the -48 V DC Scenario


When a BTS3900A is in the configuration of 1 TMC11H+2 RFCs and is supplied with -48 V
DC power, the monitoring signal cable connections are shown in the following figure.

Figure 2-61 Monitoring signal cable connections in the configuration of 1 TMC11H+2 RFCs

The following table describes the monitoring signal cable connections.

Table 2-42 Monitoring signal cable connections in the configuration of 1 TMC11H+2 RFCs
No. Description

S1 and S11 Monitoring Signal Cable for the Door Status


Sensor

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 76


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

No. Description

S2 Monitoring Signal Cable for the EMUA


CMUEA-BBU Monitoring Signal Cable

S3 Monitoring Signal Transfer Cable for the Fan


on the Front Door

S4 and S6 CMUEA-BBU Monitoring Signal Cable

S5 and S12 ELU Signal Cable

S7 Monitoring Signal Cable Between Cascaded


CMUEAs

S8 and S14 Monitoring Signal Cable for the Fan


Assembly in the RFC

S9 and S10 Surge Protection Alarm Cable for the


DCDU-13A

S13 Monitoring Signal Cable for the


Temperature Sensor

Power Cable Connections in a DBS3900


This section describes the power cable connections in a DBS3900 supplied with 110 V AC, 220
V AC, and -48 V DC power to facilitate power cable installation and maintenance.

Power Cable Connections in a 110 V AC or 220 V AC Input Scenario


NOTE
If a device is not configured, ignore the power cable connections for the device in the figures showing
power cable connections.

When a DBS3900 is supplied with 110 V AC or 220 V AC power, 1 APM30H+1 TM11H+1


IBBS200T are configured. The following figure shows the power cable connections.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 77


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-62 Power cable connections in a base station configured with 1 APM30H+1 TM11H
+1 IBBS200T

The following table describes the power cable connections.

Table 2-43 Power cable connections in a base station configured with 1 APM30H+1 TM11H
+1 IBBS200T

No. Description

P1 Input power cable for the APM30H

P2 CMUEA power cable

P3 and P8 to P11 Power cables for the battery cabinet

P4 Input power cable for the transfer terminal

P5 BBU power cable

P6 EMUA power cable

P7 Input power cable for the TMC11H

Power Cable Connections in a -48 V DC Input Scenario


The following figure shows the power cable connections in a DBS3900 configured with 2
TMC11Hs in a -48 V DC input scenario.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 78


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-63 Power cable connections in a base station configured with two TMC11Hs

The following table describes the power cable connections.

Table 2-44 Power cable connections in a base station configured with two TMC11Hs
No. Description

P0 Input power cable for the TMC11H

P1 CMUEA power cable

P2 BBU power cable

P3 EMUA power cable

Monitoring Signal Cable Connections in a DBS3900


This section describes the monitoring signal cable connections in a DBS3900 in 110 V or 220
V AC and -48 V DC scenarios.

Monitoring Signal Cable Connections in the 110 V or 220 V AC Scenario


NOTE
If a component is not configured, ignore the monitoring signal cable connections for the component in the
figures.

When a DBS3900 is in the configuration of 1 APM30H+1 TMC11H+1 IBBS200T and is


supplied with 110 V or 220 V AC power, the monitoring signal cable connections are shown in
the following figure.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 79


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-64 Monitoring signal cable connections in the configuration of 1 APM30H+1


TMC11H+1 IBBS200T

The following table describes the monitoring signal cable connections.

Table 2-45 Monitoring signal cable connections in the configuration of 1 APM30H+1 TMC11H
+1 IBBS200T
No. Description

S1 Monitoring Signal Cable for the IBBS200T

S2 PMU-CMUEA Monitoring Signal Cable

S3 Monitoring Signal Cable for the EMUA

S4 Monitoring Signal Transfer Cable for the Fan


on the Front Door

S5 Monitoring Signal Cables for a Door Status


Sensor in an APM30H

S6 ELU Signal Cable

S7 and S8 CMUEA-BBU Monitoring Signal Cable

S9 and S10 Monitoring Signal Cable for the Door Status


Sensor

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 80


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Monitoring Signal Cable Connections in the -48 V DC Scenario


When a DBS3900 is in the configuration of two TMC11Hs and is supplied with -48 V DC power,
the monitoring signal cable connections are shown in the following figure.

Figure 2-65 Monitoring signal cable connections in the configuration of two TMC11Hs

The following table describes the monitoring signal cable connections.

Table 2-46 Monitoring signal cable connections in the configuration of two TMC11Hs

No. Description

S1 Monitoring Signal Cable for the Door Status


Sensor

S2 Monitoring Signal Cable for the EMUA

S3 Monitoring Signal Transfer Cable for the Fan


on the Front Door

S4 and S6 CMUEA-BBU Monitoring Signal Cable

S5 ELU Signal Cable

S6 Monitoring Signal Cable Between Cascaded


CMUEAs

2.7.4 Equipotential Cable


An equipotential cable connects the PGND terminals of two cabinets. It ensures equipotential
bonding between the cabinets and the safe operation of base stations.

Exterior
The following figure shows the exterior of an equipotential cable.
NOTE

When 110 V AC dual-live-wire power is supplied for the cabinet, a green equipotential cable is used.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 81


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-66 Exterior of an equipotential cable

(1) OT terminal

Description
The following table describes an equipotential cable.

Table 2-47 Equipotential cable

Cable Color Size of the OT Terminal and Cross-


Sectional Area of the Wire

Equipotential cable Green and yellow M6, 16 mm2 (0.025 in.2)


for the cabinet

2.7.5 Power Cables


This chapter describes power cables in the upgraded cabinets used by the BTS3900A and
DBS3900.

CMUEA Power Cable


A CMUEA power cable feeds power into the CMUEA.

Exterior
A CMUEA power cable has a 3V3 connector at one one and an EPC4 connector at the other
end, as shown in the following figure.

Figure 2-67 CMUEA power cable

(1) 3V3 connector (2) EPC4 connector

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 82


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Description
A CMUEA power cable consists of two wires. The following table describes the pin assignment
for the wires of a CMUEA power cable.

Table 2-48 Pin assignment for the wires of a CMUEA power cable
Wire X1 End X2 End

W1 X1.A1 X2.2

W2 X1.A3 X2.1

BBU Power Cable


A BBU power cable feeds power into a BBU. The maximum length of a BBU power cable is
20 m (0.79 in.).

Exterior
A BBU power cable has a 3V3 connector at one end and a EPC4 or EPC6 connector at the other
end, as shown in Figure 2-68 and Figure 2-69.

Figure 2-68 Exterior of a BBU power cable (1)

(1) 3V3 connector (2) EPC4 or EPC6 connector

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 83


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-69 Exterior of a BBU power cable (2)

(1) 3V3 connector (2) EPC4 or EPC6 connector

Table 2-49 lists the specifications of the cable.

Table 2-49 Specifications of the input power cable for BBU power cable

Cable Wire Wire Color in Most Wire Color in Other


Regions Regions (UK)

BBU power cable RTN(+) Black Blue

NEG(-) Black Gray

Pin Assignment
A BBU power cable consists of two wires. Table 2-50 describes the pin assignment for the wires
of a BBU power cable.

Table 2-50 Pin assignment for the wires of a BBU power cable

Wire X1 End X2 End

W1 X1.A1 X2.2

W2 X1.A3 X2.1

RFU Power Cable


An RFU power cable feeds -48 V DC power into an RFU.

Exterior
An RFU power cable has a 3V3 connector at one end and a EPC4 or EPC6 connector at the other
end, as shown in Figure 2-70 and Figure 2-71.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 84


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-70 Exterior of an RFU power cable (1)

(1) 3V3 connector (2) EPC4 or EPC6 connector

Figure 2-71 Exterior of a RFU power cable (2)

(1) 3V3 connector (2) EPC4 or EPC6 connector

Table 2-51 lists the specifications of the cable.

Table 2-51 Specifications of the input power cable for RFU power cable

Cable Wire Wire Color in Most Wire Color in Other


Regions Regions (UK)

RFU power cable RTN(+) Black Blue

NEG(-) Black Gray

Pin Assignment
An RFU power cable consists of two wires. Table 2-52 describes the pin assignment for the
wires of a RFU power cable.

Table 2-52 Pin assignment for the wires of an RFU power cable

Wire X1 End X2 End

W1 X1.A1 X2.2

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 85


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Wire X1 End X2 End

W2 X1.A3 X2.1

Power Cables in a Battery Cabinet


This section describes the input power cable for a battery cabinet, power cable between the
battery group and the short-circuiting copper bar, and copper bar between the batteries.

Exterior
Figure 2-72 shows the exterior of the input power cable for the battery cabinet, of which
maximum length is 5 m (16.40 ft).

Figure 2-72 Exterior of the input power cable for the battery cabinet

(1) OT terminal (35 mm2 or 0.054 in.2 (UL3436), M8)

NOTE
One end of the input power cable is connected to the power distribution box in the battery cabinet, and the
other end is connected to the EPU in the APM30H.

Figure 2-73 shows a cable between the battery group and the short-circuiting copper bar.

Figure 2-73 Cable between the battery group and the short-circuiting copper bar

(1) OT terminal (35 mm2 or 0.054 in.2 (UL3436), M8) (2) OT terminal (35 mm2 or 0.054 in.2 (UL3436), M6)

NOTE
The M6 OT terminal is connected to the battery, and the M8 OT terminal is connected to the power
distribution box.

Copper bars between batteries are delivered with batteries. Figure 2-74 shows a copper bar
between the batteries.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 86


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-74 Copper bar between the batteries

Specifications
l The RTN(+) wire of the input power cable for the battery is a red wire (UK is blue) with a
cross-sectional area of 35 mm2 (0.054 in.2), and the NEG(-) wire is a black wire (UK is
gray) with a cross-sectional area of 35 mm2 (0.054 in.2).
l The RTN(+) wire of the power cable between the battery group and short-circuiting copper
bar is a red wire (UK is blue) with a cross-sectional area of 35 mm2 (0.054 in.2), and the
NEG(-) wire is a black wire (UK is gray) with a cross-sectional area of 35 mm2 (0.054 in.
2).

Input Power Cable for the APM30H


An input power cable for the APM30H feeds external AC power into the power system of the
APM30H. Different power systems enable a cabinet to support power supplies of 220 V AC
single-phase, 220 V AC three-phase, and 110 V/220 V dual-live-wire.

Exterior
Figure 2-75 shows a 220 V AC single-phase input power cable.

Figure 2-75 Exterior of a 220 V AC single-phase input power cable

(1) OT terminal

NOTE

Different types of AC input power cables consist of different numbers of core wires. Figure 2-75 shows
the inner structure of a 220 V AC single-phase input power cable.

Specifications
Table 2-53 lists the specifications of different types of AC input power cables.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 87


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-53 Specifications of the AC input power cable

Cable Wire Wire Color Cross-Sectional Area


of the Core Wire and
Size of the OT
Terminal

220 V AC three- L1 wire Brown M6, 4 mm2 (0.006 in.2)


phase power cable
L2 wire Black

L3 wire Gray

N wire Blue

220 V AC single- L wire Brown M6, 16 mm2 (0.025 in.2)


phase power cable
N wire Blue

110 V AC dual- L1 wire Black M6, 16 mm2 (0.025 in.2)


live-wire
L2 wire Red

N wire White

NOTE

The colors and structures of cables delivered by Huawei vary according to countries and areas. If cables
are purchased at local markets, the cables must comply with local rules and regulations.

Input Power Cable for the TMC11H


The type of input power cable for the TMC11H depends on the power supply to the TMC11H.

Input Power Cable for the TMC11H (1)


In a BTS3900A or DBS3900 supplied with AC power, the TMC11H is powered by the APM30H,
and the maximum length of the input power cable is 15 m (49.21 ft) or 10 m (32.81 ft). The
following figure shows the exterior of an input power cable for the TMC11H.

Figure 2-76 Input power cable for the TMC11H (1)

(1) EPC4 or EPC6 connector (2) OT terminal

The following table describes an input power cable for the TMC11H.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 88


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-54 Input power cable for the TMC11H (1)

Cable Wire Wire Color Size of the OT Terminal


and Cross-Sectional Area
of the Wire

Input power cable RTN(+) Black M6, 4 mm2 (0.006 in.2)


for the TMC11H
(1) NEG(-) Blue

Input Power Cable for the TMC11H (2)


In -48 V DC scenarios, if the TMC11H is powered by the external power equipment, the
maximum length of the input power cable is 10 m (32.81 ft). The following figure shows the
exterior of an input power cable for the TMC11H.

Figure 2-77 Input power cable for the TMC11H (2)

(1) OT terminal

The following table describes an input power cable for the TMC11H.

Table 2-55 Input power cable for the TMC11H (2)

Cable Wire Wire Color Size of the OT Terminal


and Cross-Sectional Area
of the Wire

Input power cable RTN(+) Black M6, one pair of wires with a
for the TMC11H cross-sectional area of 35
(3) NEG(-) Blue mm2 (0.054 in.2), two pairs
of wires with a cross-
sectional area of 16 mm2
(0.025 in.2)

Input Power Cable for the TMC11H (3)


When the TMC11H is used as a transmission cabinet, the specifications of its power cable are
as follows:

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 89


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

In a BTS3900A or DBS3900 supplied with -48 V DC power, if the TMC11H is powered by the
external power equipment, the maximum length of the input power cable is 15 m (49.21 ft) or
10 m (32.81 ft). The following figure shows the exterior of an input power cable for the TMC11H.

Figure 2-78 Input power cable for the TMC11H (3)

(1) OT terminal (M6, 4 mm2 or 0.006 in.2)

Input Power Cable for the RFC


An input power cable for the RFC feeds -48 V DC power into the left DCDU-13A in the RFC,
and the -48 V DC power is then distributed to the RFC.

NOTE

The RFCs configured for the BTS3900A in different scenarios are supplied with different types of power,
and use different input power cables.

Input Power Cable for the RFC in AC Scenarios


When a BTS3900A is supplied with AC power, the RFC is powered by the EPU in the APM30,
and the input power cable is connected from the APM30 to the left DCDU-13A in the RFC.

The following figure shows an input power cable from the APM30 to the RFC.

Figure 2-79 Input power cable for the RFC in AC scenarios

(1) OT terminal (2) OT terminal

The following table describes an input power cable for the RFC in AC scenarios.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 90


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-56 Input power cable for the RFC in AC scenarios

Cable Wire Wire Color in Wire Color in Size of the OT


Most Regions Other Regions Terminal and
Cross-Sectional
Area of the Wire

Input power RTN Black Blue M6, 25 mm2 (0.039


cable for the (+) in.2)
RFC in AC
scenarios NEG Blue Gray
(-)

Input Power Cable for the RFC in DC Scenarios


When a BTS3900A is supplied with -48 V DC power, the RFC is powered by the external power
equipment, and the input power cable is connected from the external power equipment to the
left DCDU-13A in the RFC.
The following figure shows the input power cable from the external power equipment to the left
DCDU-13A in the RFC.

Figure 2-80 Input power cable for the RFC in DC scenarios

(1) OT terminal

The following table describes an input power cable for the RFC in DC scenarios.

NOTE
An input power cable for the RFC in DC scenarios supports two types of power supplies: 1x160 A and
2x80 A, and one group of 35 mm 2 (0.054 in. 2) cables or two groups of 16 mm 2 (0.025 in. 2) cables can
be used. Each group of cable consists of two wires: RTN(+) and NEG(-).

Table 2-57 Input power cable for the RFC in DC scenarios

Cable Wire Wire Color in Wire Color in Size of the OT


Most Regions Other Regions Terminal and
Cross-Sectional
Area of the Wire

Input power RTN Black Blue M6, 35 mm2 (0.54 in.


cable for the (+) 2)
RFC
NEG Blue Gray
(-)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 91


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Cable Wire Wire Color in Wire Color in Size of the OT


Most Regions Other Regions Terminal and
Cross-Sectional
Area of the Wire

Input power RTN Black Blue M6, 16 mm2 (0.025


cable for the (+) in.2)
RFC
NEG Blue Gray
(-)

Power Cable Between Cascaded DCDU-13As


When both the RFC and APM30 are used, the RFC is configured with two DCDU-13As. The
APM30 supplies one input to the left DCDU-13A, and the right DCDU-13A is cascaded with
the left DCDU-13A.

The following figure shows the exterior of a power cable between cascaded DCDU-13As.

Figure 2-81 Power cable between cascaded DCDU-13As

(1) OT terminal

The following table describes a power cable between cascaded DCDU-13As.

Table 2-58 Power cable between cascaded DCDU-13As

Cable Wire Wire Color in Wire Color in Size of the OT


Most Regions Other Regions Terminal and
Cross-Sectional
Area of the Wire

Power cable RTN Black Blue M6, 25 mm2 (0.039


between (+) in.2)
cascaded
DCDU-13As NEG Blue Gray
(-)

TEC Power Cables


TEC power cables consist of the TEC input power cable and TEC power transfer cable, feeding
power into the TEC.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 92


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

TEC Input Power Cable


Figure 2-82 shows the exterior of the TEC input power cable.

Figure 2-82 Exterior of a TEC input power cable

(1) EPC4 or EPC6 connector

Table 2-59 lists the specifications of the cable.

Table 2-59 Specifications of a TEC input power cable

Cable Wire Wire Color in Most Wire Color in Other


Regions Regions (UK)

TEC input power RTN(+) Black Blue


cable
NEG(-) Blue Gray

TEC Power Transfer Cable


Figure 2-83 shows the exterior of the TEC power transfer cable.

Figure 2-83 Exterior of the TEC power transfer cable

(1) 3V3 connector (2) OT terminal (M4, 2.5 mm2 or 0.004 in.2)

Table 2-60 lists the specifications of the cable.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 93


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-60 Specifications of a TEC power transfer cable

Cable Wire Wire Color in Most Wire Color in Other


Regions Regions (UK)

TEC power transfer W1 Blue Gray


cable
W2 Black Blue

Power Cable for the EMUA


A power cable for the EMUA leads -48 V DC power to the EMUA.

Exterior
Figure 2-84 shows a power cable for the EMUA.

Figure 2-84 Power cable for the EMUA

(1) Tool-less female connector (pressfit type) (2) Cord end terminal

Cable Specification
Table 2-61 describes the specifications of the power cable for the EMUA.

Table 2-61 Specifications of the power cable for the EMUA

Cable Wire Wire Color in Most Wire Color in Other Area


Area

Power cable for the RTN(+) Black Blue


EMUA
NEG(-) Blue Gray

2.7.6 Signal Cables


This chapter describes all monitoring signal cables in the upgraded cabinets in a BTS3900A and
a DBS3900.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 94


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

CMUEA-BBU Monitoring Signal Cable


A CMUEA-BBU monitoring signal cable connects the CMUEA and the BBU and transmits the
monitoring signals collected by the CMUEA to the BBU.

Exterior
Figure 2-85 shows a CMUEA-BBU monitoring signal cable.

Figure 2-85 Exterior of a CMUEA-BBU monitoring signal cable

(1) RJ45 connector

Pin Assignment
Table 2-62 describes the pin assignment for the wires of a CMUEA-BBU monitoring signal
cable.

Table 2-62 Pin assignment for the wires of a CMUEA-BBU monitoring signal cable

X1 End X2 End Wire Color Type

X1.1 X2.1 White Twisted pair

X1.2 X2.2 Orange

X1.3 X2.3 White Twisted pair

X1.6 X2.6 Green

X1.5 X2.5 White Twisted pair

X1.4 X2.4 Blue

X1.7 X2.7 White Twisted pair

X1.8 X2.8 Brown

Monitoring Signal Cables for a Door Status Sensor in an APM30H


The monitoring signal cable for a door status sensor in an APM30H transmits the alarms from
the door status sensor to the PMU. The PMU reports the alarms to the BBU.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 95


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Exterior
Figure 2-86 shows the exterior of the monitoring signal cable for a door status sensor in an
APM30H.

Figure 2-86 Exterior of the monitoring signal cable for a door status sensor

The description of the monitoring signal cable for a door status sensor is as follows:
l Cable 1 has a 2-pin straight socket at one end, which is connected to the GATE port on the
PMU. Cable 1 has a bare wire and a cord end terminal at the other end, which are connected
to a door status sensor and cable terminal block, respectively.
l Cable 2 has a bare wire at one end, which is connected to a door status sensor. Cable 2 has
a cord end terminal at the other end, which is connected to a cable terminal block.
l Cable 3 has a cord end terminal at each end. The two cord end terminals are connected to
the two ports on one side of the cable terminal block.

Monitoring Signal Cable for the IBBS200T


A monitoring signal cable for the IBBS200T transmits the information collected by the door
status sensor, smoke sensor, and temperature sensor for storage batteries as well as alarms about
the TEC to the monitoring board in the APM30H.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 96


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Exterior
The following figure shows the exterior of a monitoring signal cable for the IBBS200T.

Figure 2-87 Monitoring signal cable for the IBBS200T

(1) 4-pin connector (2) 2-pin connector (3) Cord end terminal

Description
The following table describes a monitoring signal cable for the IBBS200T.

Table 2-63 Monitoring signal cable for the IBBS200T

One End of The Other Color Wire Label


the Wire End of the Type
Wire

X1.3 X7 White Twisted TEC Alarm-


pair

X1.2 X8 Blue Twisted TEC Alarm+


pair

X2.1 X9 White Twisted BAT_TEMP Alarm+


pair

X2.2 X10 Orange Twisted BAT_TEMP Alarm-


pair

X3 X11 White Twisted SMOKE Alarm+


pair

X4 X12 Brown Twisted SMOKE Alarm-


pair

X5 X13 White Twisted DOOR Alarm


pair

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 97


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

One End of The Other Color Wire Label


the Wire End of the Type
Wire

X6 X14 Green Twisted DOOR Alarm


pair

ELU Signal Cable


The electronic label unit (ELU) signal cable is used by the ELU to report the cabinet type to the
central monitoring unit type EA (CMUEA).

Exterior
Figure 2-88 shows the exterior of an ELU signal cable.

Figure 2-88 Exterior of an ELU signal cable

(1) RJ45 connector

Cable Description
Table 2-64 describes the pin assignment for the wires of an ELU signal cable.

Table 2-64 Pin assignment for the wires of an ELU signal cable
X1 End X2 End Color Type

X1.1 X2.1 White Twisted pair

X1.2 X2.2 Orange

X1.3 X2.3 White Twisted pair

X1.6 X2.6 Green

X1.5 X2.5 White Twisted pair

X1.4 X2.4 Blue

X1.7 X2.7 White Twisted pair

X1.8 X2.8 Brown

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 98


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Monitoring Signal Transfer Cable for the Fan on the Front Door
The monitoring signal transfer cable for the fan on the front door feeds power to the fan on the
front door in the APM30H or TMC11H and reports fan monitoring signals to the central
monitoring unit type EA (CMUEA).

Exterior
Figure 2-89 shows the exterior of the monitoring signal transfer cable for the fan on the front
door.

Figure 2-89 Exterior of the monitoring signal transfer cable for the fan on the front door

(1) 4-pin connector (2) Interconnection terminal

Cable Description
Table 2-65 shows the pin assignment for the wires of the monitoring signal transfer cable for
the fan on the front door.

Table 2-65 Pin assignment for the wires of the monitoring signal transfer cable for the fan on
the front door
Cable X1 End X2 End Color

W1 X1.1 X2.1 Black

W2 X1.2 X2.2 Black

W3 X1.3 X2.3 Black

W4 X1.4 X2.4 Black

Monitoring Signal Cable for the Door Status Sensor


A monitoring signal cable for the door status sensor informs the monitoring board of the door
status obtained from the door status sensors in the TMC11H, RFC, IBBS200D, IBBS200T,
IBBS700D, or IBBS700T.

Exterior
There are two wires in a monitoring signal cable for a door status sensor, both of which have a
bare wire at each end, as shown in Figure 2-90.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 99


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Figure 2-90 Exterior of a monitoring signal cable for the door status sensor

Surge Protection Alarm Cable for the DCDU-13A


A surge protection alarm cable for the DCDU-13A transmits surge protection dry contact alarm
signals of the DCDU-13A to the CMUEA. The maximum length of a surge protection alarm
cable for the DCDU-13A is 0.8 m (31.50 in.).

Both ends of a surge protection alarm cable for the DCDU-13A are bare wires, as shown in the
following figure.

Figure 2-91 Surge protection alarm cable for the DCDU-13A

PMU-CMUEA Monitoring Signal Cable


The PMU-CMUEA monitoring signal cable transmits the RS485 signals collected by the PMU
to the BBU through the CMUEA. This monitoring signal cable is 1.1 m (3.61 ft) long.

Exterior
The monitoring signal cable is black and has an RJ45 connector at each end, as shown in Figure
2-92.

Figure 2-92 Exterior of a monitoring signal cable

(1) RJ45 connector

Cable Description
Table 2-66 describes the pin assignment for the wires of a monitoring signal cable.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 100


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-66 Pin assignment for the wires of a monitoring signal cable

X1 End X2 End Description

X1.1 X2.1 Twisted pair

X1.2 X2.2

X1.3 X2.3 Twisted pair

X1.6 X2.6

X1.4 X2.4 Twisted pair

X1.5 X2.5

X1.7 X2.7 Twisted pair

X1.8 X2.8

Monitoring Signal Cable Between Cascaded CMUEAs


Cascaded CMUEAs are connected by signal cables. The lower-level CMUEA can communicate
with the BBU through the upper-level CMUEA.

Exterior
Figure 2-93 shows a monitoring signal cable between cascaded CMUEAs.

Figure 2-93 Exterior of a monitoring signal cable between cascaded CMUEAs

(1) RJ45 connector

Pin Assignment
Table 2-67 describes the pin assignment for the wires of the monitoring signal cable between
cascaded CMUEAs.

Table 2-67 Pin assignment for the wires of the monitoring signal cable between cascaded
CMUEAs

X1 End X2 End Wire Color Type

X1.1 X2.1 White Twisted pair

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 101


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

X1 End X2 End Wire Color Type

X1.2 X2.2 Orange

X1.3 X2.3 White Twisted pair

X1.6 X2.6 Green

X1.4 X2.4 White Twisted pair

X1.5 X2.5 Blue

X1.7 X2.7 White Twisted pair

X1.8 X2.8 Brown

Monitoring Signal Cable for the EMUA


A monitoring signal cable for the EMUA transmits monitoring signals from an EMUA to a BBU.
This cable is delivered with the EMUA.

Exterior
Figure 2-94 shows the monitoring signal cable for the EMUA.

Figure 2-94 Monitoring signal cable for the EMUA

(1) RJ45 connector (2) DB9 male connector

Pin Assignment
Table 2-68 describes the pin assignment for the wires of the monitoring signal cable for the
EMUA.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 102


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 2 Upgrade from APM30H (Ver.A) Series Cabinets to
Hardware Description for Enhanced Cabinets APM30H (Ver.D_A2) Series Cabinets

Table 2-68 Pin assignment for the wires of the monitoring signal cable for the EMUA
Pin on the DB9 male Color Description Associated
RJ45 connector Port on the
Connector APMI

X1.1 X2.3 White Twisted pair TX+

X1.2 X2.7 Orange TX-

X1.5 X2.6 White Twisted pair RX-

X1.4 X2.2 Blue RX+

Monitoring Signal Cable for the Temperature Sensor


A monitoring signal cable for the temperature sensor transmits the temperature signals to the
central monitoring unit type EA (CMUEA). One end of the cable is connected to the temperature
sensor and the other end is connected to the port on the CMUEA.
The following figure shows the exterior of a monitoring signal cable for the temperature sensor.

Figure 2-95 Monitoring signal cable for the temperature sensor

(1) 4-pin connector (2) 5-pin connector

An ambient temperature sensor and a temperature sensor at the air intake vent are installed in
an APM30. Therefore, two monitoring signal cables are required. For the positions of the
temperature sensors, see 3.2.3 Temperature Sensors.
An ambient temperature sensor is installed in an RFC. Therefore, one monitoring signal cable
is required.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 103


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

3 Upgrade from APM30 Series Cabinets to


APM30H (Ver.D_A1) Series Cabinets

About This Chapter

APM30 series cabinets include the APM30, TMC, BBC, and RFC. This chapter describes the
components replaced during the upgrade of the APM30, TMC, and BBC. In addition, it describes
the cables and cable connections in the BTS3900A (Ver.D_A1) (shortened to BTS3900A in this
document) and DBS3900 (Ver.D_A1) (shortened to DBS3900 in this document).

3.1 BTS3900A&DBS3900 Cabinets Interior


To meet requirements in different outdoor environments, Huawei provides various cabinets for
the separated macro base station such as BTS3900A (Ver.D_A1) and distributed base station
such as DBS3900 (Ver.D_A1). The cabinets include the APM30, TMC, RFC, and BBC, which
provide different functions.
3.2 APM30 Components to Be Replaced During the Upgrade
During the APM30 hardware upgrade, the following components need to be replaced: the door
of the cabinet, CMUEA, fan on the top of the cabinet interior, and AC/DC power system.
3.3 TMC Components to Be Replaced During the Upgrade
During the TMC hardware upgrade, the following components need to be replaced: the door of
the cabinet, CMUEA, fan on the top of the cabinet interior, and AC/DC power system.
3.4 RFC Components to Be Replaced During the Upgrade
During the RFC hardware upgrade, the following components need to be replaced: the
DCDU-13A, CMUEA, and fan assembly.
3.5 BBC Components to Be Replaced During the Upgrade
During the BBC hardware upgrade, the following components need to be replaced: positive and
negative wiring terminals for storage batteries, circuit breaker for the storage battery group, and
positive and negative power input terminals for the storage battery group.
3.6 Auxiliary Equipment
This section describes the auxiliary equipment to be replaced during the hardware upgrade from
APM30H (Ver.A) series cabinets to APM30H (Ver.D) series cabinets. The auxiliary equipment
includes the Signal Lightning Protection Unit (SLPU), Outdoor Fiber Distribution, 6 (OFD06),
Outdoor Distribution Module DC, 6 (ODM06D-3).

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 104


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

3.7 BTS3900A&DBS3900 Cables


This section describes the PGND cables, power cables, and signal cables that need to be installed
or maintained after the BTS3900A&DBS3900 hardware upgrade.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 105


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

3.1 BTS3900A&DBS3900 Cabinets Interior


To meet requirements in different outdoor environments, Huawei provides various cabinets for
the separated macro base station such as BTS3900A (Ver.D_A1) and distributed base station
such as DBS3900 (Ver.D_A1). The cabinets include the APM30, TMC, RFC, and BBC, which
provide different functions.

APM30 Interior
The following figure shows the APM30 interior.

Figure 3-1 APM30 interior

The following table describes the components in the APM30.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 106


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-1 Components in the APM30


N Compone Op Ma Description
o. nt tio xim
nal um
or Qu
Ma anti
nd ty
ato in a
ry Sin
gle
Cab
inet

1 Temperatur Ma 1 It is located on the front door of the cabinet and reports the
e sensor nda ambient temperature outside the cabinet.
tor
y

2 Magnet of a Ma 1 The door status sensor reports the door status, whether
door status nda open or closed.
sensor tor
y

3 Breathable Ma 1 It is located on the front door of the cabinet and used for
film nda heat exchanging and dissipation.
tor
y

4 Filler panel Ma 1 It replaces the APM Power Monitor unit Interface Board
nda (APMI) and is used as an air damper.
tor
y

5 Fan Ma 1 The fan assembly on the top of the cabinet interior consists
assembly nda of the support, fan interface board, and fan. The support is
on the top of tor newly developed. The fan interface board and fan are
the cabinet y reused.
interior

6 CMUEA Ma 1 The Central Monitoring Unit type EA (CMUEA) assembly


assembly nda consists of the support, CMUEA, and electronic label unit
tor (ELU).
y

7 EPU Ma 1 The EPU converts AC power to DC power and feeds the


nda DC power into the devices in the cabinet. The EPU consists
tor of the EPU subrack, PMU, and PSUs.
y

8 BBU Ma 1 The BBU is installed in the 2 U space below the EPU,


nda processing baseband signals.
tor
y

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 107


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

N Compone Op Ma Description
o. nt tio xim
nal um
or Qu
Ma anti
nd ty
ato in a
ry Sin
gle
Cab
inet

9 SLPU Ma 2 l To provide protection for trunk signals, a signal


nda lightning protection unit (SLPU) is mandatory and
tor installed in the top 1 U space of the cabinet. It is
y configured with the universal E1/T1 lightning
protection unit (UELP) or universal FE lightning
protection unit (UFLP).
l To provide protection for monitoring signals, an SLPU
is optional and installed in the 1 U space below the
BBU. It is configured with two universal signal
lightning protection unit 2 (USLP2) boards.

10 GATM Opt 2 The GSM Antenna and TMA Control module (GATM)
ion reports the RET control alarm signals.
al

11 EMUA Opt 1 An environment monitoring unit type A (EMUA) monitors


ion the environment in a cabinet and processes alarms. The
al EMUA must be configured when more than 16 Boolean
alarm inputs are required. It is installed in the 1 U space
below the BBU.

12 AC heater Opt 1 The AC heater ensures that components in the cabinet work
ion within the acceptable temperature range when the
al surrounding temperature is low. It can be installed in the 1
U space at the bottom of the cabinet. If both an AC heater
and an SOU are configured, the heater is installed in the 1
U space above the SOU.

13 SOU Opt 1 The SOU can be installed in the 1 U space at the bottom of
ion the cabinet, transferring AC power supply to the customer
al equipment.

TMC Interior
There are two types of TMC:

l One type of TMC houses only transmission equipment, as shown in illustration A in the
following figure.
l The other type of TMC houses the BBU3900 and uses the -48 V DC power supply, as
shown in illustration B in the following figure.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 108


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-2 TMC interior

The following table describes the components in the TMC.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 109


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-2 Components in the TMC


N Compone Op Ma Description
o. nt tio xim
nal um
or Qu
Ma anti
nd ty
ato in a
ry Sin
gle
Cab
inet

1 Temperatur Ma 1 It is located on the front door of the cabinet and reports the
e sensor nda ambient temperature outside the cabinet.
tor
y

2 Magnet of a Ma 1 The door status sensor reports the door status, whether
door status nda open or closed.
sensor tor
y

3 Breathable Ma 1 It is located on the front door of the cabinet and used for
film nda heat exchanging and dissipation.
tor
y

4 Filler panel Ma 1 It is used as an air damper when replacing the APM Power
nda Monitor unit Interface Board (APMI).
tor
y

5 Fan Ma 1 The fan assembly on the top of the cabinet interior consists
assembly nda of the support, fan interface board, and fan. The support is
on the top of tor newly developed. The fan interface board and fan are
the cabinet y reused.
interior

6 CMUEA Ma 1 The Central Monitoring Unit type EA (CMUEA) assembly


assembly nda consists of the support, CMUEA, and electronic label unit
tor (ELU).
y

7 DCDU Ma 1 The direct current distribution unit (DCDU), such as the


nda DCDU-12B and DCDU-12C, is 1 U high and provides ten
tor DC power outputs for components in the TMC.
y

8 BBU Ma 1 It is a baseband processing unit.


nda
tor
y

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 110


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

N Compone Op Ma Description
o. nt tio xim
nal um
or Qu
Ma anti
nd ty
ato in a
ry Sin
gle
Cab
inet

9 SLPU Ma 2 l To provide protection for trunk signals, a signal


nda lightning protection unit (SLPU) is mandatory and
tor installed in the top 1 U space of the cabinet. It is
y configured with the universal E1/T1 lightning
protection unit (UELP) or universal FE lightning
protection unit (UFLP).
l To provide protection for monitoring signals, an SLPU
is optional and installed in the 1 U space below the
BBU. It is configured with two universal signal
lightning protection unit 2 (USLP2) boards.

10 GATM Opt 2 The GSM Antenna and TMA Control module (GATM)
ion reports the RET control signal alarms.
al

11 EMUA Opt 1 An environment monitoring unit type A (EMUA) monitors


ion the environment in a cabinet and processes alarms. The
al EMUA must be configured when more than 16 Boolean
alarm inputs are required. It is installed in the 1 U space
below the BBU.

12 AC heater Opt 1 The AC heater ensures that components in the cabinet work
ion within the acceptable temperature range when the
al surrounding temperature is low. It can be installed in the 1
U space at the bottom of the cabinet. If both an AC heater
and an SOU are configured, the heater is installed in the 1
U space above the SOU.

RFC Interior
The Radio Frequency Cabinet (RFC) is used by the BTS3900A and provides installation space
for RFUs. The following figure shows the RFC interior.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 111


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-3 RFC interior

The following table describes the components in the RFC.

Table 3-3 Components in the RFC


No. Module/ Optional Maximum Description
Board or Quantity
Mandato in a Single
ry Cabinet

1 DCDU-13 Mandator 2 The DCDU-13A is a direct current


A y distribution unit. It provides four 30 A and
-48 V DC power outputs.

2 CMUEA Mandator 1 The Central Monitoring Unit type EA


assembly y (CMUEA) assembly consists of the support
and CMUEA.

3 ELU Mandator 1 The ELU assembly consists of a support


assembly y and an electronic label unit (ELU). The
ELU automatically reports the cabinet type.

4 Fan Mandator 2 A fan assembly dissipates heat from the


assembly y cabinet. It contains two standalone fans.

5 RFUs Mandator 6 Radio frequency units (RFUs) are used in


y macro base stations. They perform
modulation and demodulation of baseband
signals and RF signals, data processing,
power amplifying, and VSWR test.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 112


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

BBC Interior
The following figure shows the BBC interior.

Figure 3-4 BBC interior

The following table describes the components in the BBC.

Table 3-4 Components in the BBC

No. Module/ Optiona Maximu Description


Board l or m
Mandat Quantity
ory in a
Single
Cabinet

1 Junction Mandator 1 The junction terminal provides the input


terminal for y power port for the heating film
the input
power cable
of the heating
film

2 Storage Mandator 8 The storage batteries provide long-


battery y duration backup power for a base station.

3 Negative Mandator 1 It feeds power into the battery cabinet.


power input y
terminal for
the storage
battery group

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 113


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No. Module/ Optiona Maximu Description


Board l or m
Mandat Quantity
ory in a
Single
Cabinet

4 Positive Mandator 1 It feeds power into the battery cabinet.


power input y
terminal for
the storage
battery group
(positive
wiring
terminal for
storage
batteries)

5 Circuit Mandator 1 It controls whether to connect the


breaker for the y external power supply to the storage
storage batteries.
batteries

6 Negative Mandator 1 -
wiring y
terminal for
storage
batteries

3.2 APM30 Components to Be Replaced During the Upgrade


During the APM30 hardware upgrade, the following components need to be replaced: the door
of the cabinet, CMUEA, fan on the top of the cabinet interior, and AC/DC power system.
The following table describes the APM30 components to be replaced during the upgrade.

Before the Upgrade After the Upgrade

Cabinet door assembly (with a Cabinet door assembly (with a breathable film, a fan,
breathable film, a door status sensor, a door status sensor, a temperature sensor, and a
and a temperature sensor) PGND cable for the door)

AFMU (with a support) CMUEA assembly (including a support, an ELU, and


the CMUEA)

Fan assembly (including a support, a Fan assembly (including a support, a fan, and a fan
fan, and a fan interface board) on the interface board) on the top of the cabinet interior
top of the cabinet interior

APMI assembly (including a support Filler panel


and the APMI)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 114


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Before the Upgrade After the Upgrade

PSU4890 (including the PSUs and EPU05-0X (including the PMU and PSUs)
PMU) and PDU

3.2.1 Front Door


The front door of the cabinet consists of a door frame, a breathable film, fans, a temperature
sensor, a magnet of the door status sensor, and a PGND cable. These components have been
assembled before delivery. The door frame and breathable film are newly developed. Others
components are reused.
The following figure shows the structure of the front door.

Table 3-5 Components of the front door


No. Component Description

1 Magnet of a door The door status sensor reports the door status.
status sensor It consists of a switch and a magnet. The switch is
located on an inner wall of the cabinet and will not be
removed during the upgrade. The magnet is located
on the front door (as shown in the preceding figure)
and will be removed with the door. A new magnet will
be delivered with a new door.

2 Fans in the front door The fans on the top of the cabinet interior are reused.
They dissipate heat from the cabinet.

3 Door frame -

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 115


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No. Component Description

4 Breathable film It is newly developed for heat exchanging and


dissipation.

5 Temperature sensor It monitors the environmental temperature of the


cabinet.

6 Ground screw It connects the equipotential cable to the inner wall of


the cabinet.

3.2.2 Door Status Sensor


A door status sensor is used for monitoring the cabinet door status, whether open or closed.
The door status sensor consists of a magnet and a switch. The magnet is located on the door of
the cabinet, and the switch is located on the top right side of the cabinet interior.
There is a door status sensor in an APM or a TMC. The following figure shows the door status
sensor in an APM.

Figure 3-5 Door status sensor

3.2.3 Temperature Sensors


The temperature sensor on the door of the cabinet is an environmental temperature sensor. It
monitors the environmental temperature outside the cabinet and reports it to the CMUEA.
There is also a temperature sensor near the air exhaust vent on the right side of the fan assembly,
which is located on the top of the cabinet interior, as shown in the following figure. This
temperature sensor monitors the internal temperature of the cabinet.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 116


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-6 Positions of the temperature sensors

3.2.4 CMUEA Assembly


The CMUEA assembly is a central monitoring unit. It is used for monitoring and reporting the
type of the cabinet.

CMUEA Assembly
The CMUEA assembly consists of the CMUEA, ELU, and a support.
l The following figure shows the CMUEA components in the APM30 and TMC.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 117


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-7 CMUEA components

(1) Central Monitoring Unit Type EA (CMUEA) (2)ELU

l The following figure shows the CMUEA components in the RFC.

Figure 3-8 CMUEA components

(1) Support (2) Central Monitoring Unit Type EA (CMUEA)

For details about the ports and indicators on the CMUEA, see Central Monitoring Unit
Type EA (CMUEA).

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 118


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Central Monitoring Unit Type EA (CMUEA)


The central monitoring unit type EA (CMUEA) mainly monitors the fans, heater, and cabinet
temperature. The CMUEA can be used in an AMP30H, RFC, TMC11H, IBBS200D, or
IBBS200T.

Exterior
Figure 3-9 shows the exterior of a CMUEA.

Figure 3-9 Exterior of a CMUEA

Ports
Figure 3-10 shows the ports on a CMUEA.

Figure 3-10 Ports on a CMUEA

Table 3-6 describes the ports on a CMUEA.

Table 3-6 Ports on a CMUEA

No Port Remarks
.

(1) TEMP2 Reserved port, connected to the temperature sensor

(2) WATER Connected to the water sensor

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 119


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No Port Remarks
.

(3) IFAN4 Connected to the inner circulation fan for the cabinet

(4) IFAN3 Connected to the inner circulation fan for the cabinet

(5) IFAN2 Connected to the inner circulation fan for the cabinet

(6) IFAN1 Connected to the inner circulation fan for the cabinet

(7) TEC Connected to the TEC cooler to receive alarms related to the TEC cooler

(8) TEMP1 l In the RFC, this port is connected to the temperature sensor at the air
intake vent of the cabinet to receive temperature alarms.
l In the IBBS200D or IBBS200T, this port is connected to the
temperature sensor to receive battery temperature alarm signals.

(9) COM_OUT RS485 signal port. It communicates with lower-level cascading ports
and reports monitoring information.
l In the APM30H, this port is connected to the PMU.
l In the RFC, TMC11H, or IBBS200D/IBBS200T, this port is
connected to the lower-level CMUEA.

(10 COM_IN RS485 signal port. It communicates with upper-level cascading ports
) and reports monitoring information.
l In the APM30H, this port is connected to the BBU.
l In the RFC or TMC11H, this port is connected to the BBU or an
upper-level CMUEA.
l In the IBBS200T, this port is connected to the PMU or upper-level
CMUEA.

(11 RUN Indicating the running status of the fans


) indicator

(12 ALM Indicating the alarm status of the fans


) indicator

(13 ELU Port connected to the ELU to report the cabinet type
)

(14 GATE Boolean signal port connected to the door status sensor
)

(15 IN0, IN1, Reserved Boolean signal port


) and IN2

(16 SMOKE Boolean signal port connected to the smoke sensor


)

(17 EFAN1 Connected to the outer circulation fan for the cabinet
)

(18 EFAN2 Connected to the outer circulation fan for the cabinet
)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 120


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No Port Remarks
.

(19 PWR Power input port providing DC power input for the board
)

Indicators
Table 3-7 describes the indicators on the CMUEA.

Table 3-7 Indicators on the CMUEA


Silkscr Color Status Meaning
een

RUN Green Blinking (on for 1s and The board is functional and communicating
off for 1s) with the BBU properly.

Blinking (on for 0.125s The board is functional but fails to


and off for 0.125s) communicate with the BBU or the board is
not registered.

Steady on The board is in the power-on self-check


status.

Steady off The board is faulty.

ALM Red Steady off No alarm has been reported.

Steady on Alarms are generated, and the board must be


replaced.

Blinking (on for 1s and An alarm is generated, and the alarm may be
off for 1s) caused by an associated board or port fault.
Therefore, you need to locate the fault before
determining whether to replace the board.

DIP Switch
On the CMUEA, there is a DIP switch J18, which is used to set the working mode of the CMUEA
according to the cabinet type. Figure 3-11 shows the position of a DIP switch on the CMUEA.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 121


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-11 Position of a DIP switch on the CMUEA

In different types of cabinet, the DIP switch on the CMUEA is set in different ways, as shown
in Figure 3-12.

Figure 3-12 DIP switch setting on the CMUEA in different cabinets

NOTE
The white boxes indicate the positions of all bits in the DIP switch.

ELU
The electronic label unit (ELU) reports the cabinet type automatically to facilitate
troubleshooting.
The ELU is located on the CMUEA, as shown in the following figure.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 122


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-13 Exterior of an ELU

(1) Central Monitoring Unit Type EA (CMUEA) (2)ELU

3.2.5 Fan Assembly on the Top of the Cabinet Interior


The fan assembly on the top of the cabinet interior consists of the support, fan, and fan interface
board. The support is newly developed. The fan and fan interface board are reused.
The following figure shows the components of the fan assembly on the top of the cabinet interior.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 123


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-14 Components of the fan assembly on the top of the cabinet interior

No. Component Description

1 Fan The original fan is reused. It


dissipates heat from the
cabinet.

2 Fan interface board The original fan interface


board is reused. It connects to
cables and facilitates
maintenance of the fan.

3.2.6 AC/DC Power System


The AC/DC system converts 110 V/220 V AC power to -48 V DC.

Components in the AC/DC Power System


The AC/DC power system consists of the PMU 11A, PSUs (AC/D), and EPU subrack.

Figure 3-15 shows the components in the AC/DC power system.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 124


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-15 Components in the AC/DC power system

(1) PMU 11A (2) PSUs (3) Filler panel (4) EPU subrack

Table 3-8 describes the modules in the AC/DC power system.

Table 3-8 Modules in the AC/DC power system

Module Remarks

PMU 11A It is installed in slot 0. For details about the


PMU 11A, see PMU.

PSU A minimum of two PSUs must be configured.


The PSUs must be installed in adjacent slots
in the sequence from slot 1 to slot 5. For
details about PSUs, see PSU (AC/DC).

Filler panel A maximum of five PSUs can be configured


in the APM30H. Filler panels must be
installed in vacant slots.

EPU subrack For details, see EPU subrack.

EPU subrack
The APM30H supports four types of EPU subracks, which are used in a distributed base station
and a separated macro base station with different AC inputs, respectively. The EPU subrack
houses the PMU and PSUs. It also distributes AC input power and DC output power.

Subrack Types
Table 3-9 lists the types and applications of EPU subracks in the AMP30H.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 125


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-9 EPU subrack


Type Remarks Application

It is a 5 U subrack, housing a
maximum of five R4850G2
EPU05A Separated macro base station with external 220
PSUs and one PMU. It
-02 V AC input
distributes large- and small-
capacity DC power.

It is a 5 U subrack, housing a
maximum of five R4850G2
EPU05A Distributed base station with external 220 V AC
PSUs and one PMU. It
-03 input
distributes large- and small-
capacity DC power.

It is a 5 U subrack, housing a
maximum of five R4850G2
EPU05A Separated macro base station with external 110
PSUs and one PMU. It
-04 V AC input
distributes large- and small-
capacity DC power.

It is a 5 U subrack, housing a
maximum of five R4850G2
EPU05A Distributed base station with external 110 V AC
PSUs and one PMU. It
-05 input
distributes large- and small-
capacity DC power.

Exterior and Components


The EPU05A-03 and EPU05A-05 apply to a distributed base station. Figure 3-16 and Figure
3-17 show the exteriors of the EPU05A-03 and EPU05A-05, respectively.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 126


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-16 Exterior of an EPU05A-03 subrack

(1) PSU (2) AC surge protector (3) PSU1/4 circuit breaker, (4) AC OUTPUT circuit
PSU2/5 circuit breaker, breaker
and PSU3 circuit breaker

(5) BAT circuit breaker (6) Circuit breaker for (7) Output port for the (8) RFC1 output port
RFC1 battery

(9) LOAD0 to LOAD8 (10) RRU0 to RRU5 (11) Spare fuse box (12) AC INPUT
output ports output ports

(13) AC OUTPUT (14) PMU (15) Short-circuiting bar(1) -

NOTE
(1) On an EPU subrack with 220 V AC single-phase input, a short-circuiting bar is installed on the AC
INPUT wiring terminal to connect the L1, L2, and L3 terminals. On an EPU subrack with 220 V AC three-
phase input, there is no short-circuiting bar on the AC INPUT wiring terminal.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 127


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-17 Exterior of an EPU05A-05 subrack

(1) PSU (2) AC surge protector (3) PSU circuit breaker (4) AC OUTPUT1/AC
OUTPUT2 circuit breaker

(5) BAT circuit breaker (6) Circuit breaker for (7) Output port for the (8) RFC1 output port
RFC1 battery

(9) LOAD0 to LOAD8 (10) RRU0 to RRU5 (11) Spare fuse box (12) AC INPUT
output ports output ports

(13) AC OUTPUT (14) PMU - -

The EPU05A-02 and EPU05A-04 apply to a separated macro base station. Figure 3-18 and
Figure 3-19 show the exteriors of the EPU05A-02 and EPU05A-04, respectively.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 128


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-18 EPU05A-02

(1) PSU (2) AC surge protector (3) PSU1/4 circuit breaker, (4) AC OUTPUT circuit
PSU2/5 circuit breaker, breaker
and PSU3 circuit breaker

(5) BAT circuit breaker (6) Circuit breaker for RFC1 (7) Circuit breaker for (8) Output port for the
RFC2 battery

(9) RFC1 output port (10) RFC2 output port (11) LOAD0 to LOAD8 (12) Spare fuse box
output ports

(13) AC INPUT (14) AC OUTPUT (15) PMU (16) Short-circuiting bar(1)

NOTE
(1) On an EPU subrack with 220 V AC single-phase input, a short-circuiting bar is installed on the AC
INPUT wiring terminal to connect the L1, L2, and L3 terminals. On an EPU subrack with 220 V AC three-
phase input, there is no short-circuiting bar on the AC INPUT wiring terminal.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 129


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-19 EPU05A-04

(1) PSU (2) AC surge protector (3) PSU circuit breaker (4) AC OUTPUT1/AC
OUTPUT2 circuit breaker

(5) BAT circuit breaker (6) Circuit breaker for (7) Circuit breaker for (8) Output port for the battery
RFC1 RFC2

(9) RFC1 output port (10) RFC2 output port (11) LOAD0 to LOAD8 (12) Spare fuse box
output ports

(13) AC INPUT (14) AC OUTPUT (15) PMU -

Functions
The EPU distributes AC and DC power.

l The EPU performs the following AC power distribution functions:


– Providing two AC outputs. One is used for the service outlet unit (SOU). The other one
is connected to the junction box on the left of the cabinet, and divided into four AC
power outputs, which are then provided for the heater or heating film.
– The AC surge protector reports AC input surge protection alarms.
l The EPU provides 17 or 12 DC outputs for a distributed base station or separated macro
base station.

Table 3-10 lists the DC power distribution functions of the EPU subrack of the APM30H in a
distributed base station.

Table 3-10 DC power distribution functions of the EPU subrack in a distributed base station

DC Power DC output Protector Protector Protector DC Output


Supply ports Specificati Quantity Ports
Unit on

BBU LOAD0 Fuse(1) 30 A 2 EPC4, EPC5,


and or EPC6
LOAD1

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 130


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

DC Power DC output Protector Protector Protector DC Output


Supply ports Specificati Quantity Ports
Unit on

Fan assembly LOAD2 1

TM_0 LOAD3 1

TM_1 LOAD4 1

TM_2 or LOAD5 1
EMUA

TM_3 or LOAD6 1
BBU

TMC LOAD7 1

IBBS LOAD8 1

RRU RRU0 to 6
RRU5

RFC RFC1 Breaker 125 A 1 OT terminal


(M6)

BAT BAT 250 A 1 OT terminal


(M8)

Table 3-11 lists the DC power distribution functions of the EPU subrack of the APM30H in a
separated macro base station.

Table 3-11 DC power distribution functions of the EPU subrack in a separated macro base station

DC Power DC output Protector Protector Protector DC Output


Supply ports Specificati Quantity Ports
Unit on

BBU LOAD0 and Fuse(2) 30 A 2 EPC4 or


LOAD1 EPC6

Fan LOAD2 1
assembly

TM_0 LOAD3 1

TM_1 LOAD4 1

TM_2 or LOAD5 1
EMUA

TM_3 or LOAD6 1
BBU

TMC LOAD7 1

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 131


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

DC Power DC output Protector Protector Protector DC Output


Supply ports Specificati Quantity Ports
Unit on

IBBS LOAD8 1

RFC1 RFC1 Breaker 125 A 1 OT terminal


(M6)

RFC2 RFC2 125 A 1 OT terminal


(M6)

BAT BAT 250 A 1 OT terminal


(M8)

NOTE
(1) and (2): The spare fuse box provides five 5 A fuses and three 30 A fuses, which can be replaced onsite.

Technical Specifications of an EPU Subrack


Table 3-12 lists the technical specifications of an EPU subrack.

Table 3-12 Technical specifications of an EPU subrack


Module Specifications

Output Voltage -58 V DC to -44 V DC

Rated Voltage -53.5 V DC

Output Current 0 A to 250 A

PMU
The power monitoring unit 11A (PMU 11A) provides the following functions: power system
management, battery management, power monitoring, and alarm reporting.

Exterior
Figure 3-20 shows the exterior of a PMU 11A.

Figure 3-20 Exterior of a PMU 11A

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 132


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Functions
The PMU 11A performs the following functions:

l Communicates with the upper-level device through an RS485 serial port.


l Manages the power system and charges and discharges storage batteries.
l Reports alarms related to the door status, standby Boolean values, and battery temperature.
l Monitors power distribution and reports alarms.
l Communicates with the battery cabinet through an RS485 serial port.

Ports
Figure 3-21 shows the ports on the front panel of the PMU 11A.

Figure 3-21 Ports on the front panel of the PMU 11A

Table 3-13 describes the ports on the front panel of the PMU 11A.

Table 3-13 Ports on the front panel of the PMU 11A

No. Silkscreen Connector Remarks

1 GATE 2-pin connector Connects to a door


status sensor

2 TEM_BAT 2-pin connector Monitors the battery


temperature sensor

3 COM_IN RJ45 connector BBU


communication port
which is connected to
the BBU or
communicates with
the upper-level
monitoring board

4 COM_OUT RJ45 connector Lower-level


monitoring board

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 133


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No. Silkscreen Connector Remarks

5 COM_485 RJ45 connector Connects to the


monitoring board in
the battery cabinet,
and receives alarm
signals from the
battery cabinet.

Indicators
Table 3-14 describes the indicators on the PMU 11A.

Table 3-14 Indicators on the PMU 11A

Silks Colo Meaning Status Meaning


creen r

RUN Gree Running Steady on The PMU 11A is performing


n indicator startup, self-check, loading, and
activation.

Blinking (on for The PMU 11A is functional and


1s and off for 1s) communicating with the main
control board in the BBU properly.
(This status does not necessarily
mean that the PMU 11A has been
configured.)

Blinking (on for The PMU 11A is functional but


0.125s and off for unable to communicate properly.
0.125s)

Steady off The PMU 11A is faulty or there is


no DC power supply.

ALM Red Alarm indicator Steady on Alarms are generated, and the
module must be replaced.

Steady off No alarm is generated.

Blinking (on for An alarm is generated and you


1s and off for 1s) need to locate the fault before
determining whether to replace the
PMU 11A.

DIP Switch
There is a DIP switch on the left panel of the PMU 11A. The DIP switch has eight bits, where
the four least significant bits (1, 2, 3, and 4) define the monitoring address of the PMU 11A, and
the four most significant bits (5, 6, 7, and 8) are not defined but reserved for future use.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 134


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

ON is indicated by 1, and OFF is indicated by 0. The monitoring address of the PMU 11A is set
to 3 by default before delivery, as shown in Figure 3-22.

Figure 3-22 DIP switch on the left panel of the PMU 11A

NOTE

When two PMU 11As share the same RS485 bus in the case that two or more APM30Hs are configured
in a base station, the monitoring address of the second PMU 11A is set to 4, the four least significant bits
(1, 2, 3, and 4) set to be 0010.

PSU (AC/DC)
The power supply unit (PSU) converts 110 V AC or 220 V AC power into -48 V DC.

Exterior
Figure 3-23 shows the exterior of a PSU.

Figure 3-23 Exterior of a PSU

Functions
The PSU performs the following functions:

l Converts 110 V AC or 220 V AC power into -48 V DC. The PMU adjusts the output voltage.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 135


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

l The DC output of the PSU provides protection against overcurrent, overvoltage, and
overtemperature.
l Dissipates heat using its built-in fans.

Indicators
Figure 3-24 shows the indicators on the PSU panel.

Figure 3-24 Indicators on the PSU panel

(1) Power indicator (2) Protection indicator (3) Fault indicator

Table 3-15 describes the indicators on the PSU panel.

Table 3-15 Indicators on the PSU


Silkscr Color Status Meaning
een

Power Green Steady on The board is functional.


indicato
r Blinking (on for 0.125s PSU online loading
and off for 0.125s)

Steady off The mains supply or PSU is faulty.

Protecti Yellow Steady off Yes


on
indicato Steady on An alarm triggered by an external factor is
r generated.

Blinking (on for 1s and The communication between the PSU and the
off for 1s) PMU is interrupted.

Fault Red Steady off Yes


indicato
r Steady on The PSU is faulty or shut down in an
emergency. Locate the fault before
determining whether to replace the PSU.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 136


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

3.3 TMC Components to Be Replaced During the Upgrade


During the TMC hardware upgrade, the following components need to be replaced: the door of
the cabinet, CMUEA, fan on the top of the cabinet interior, and AC/DC power system.
The following table describes the TMC components to be replaced during the upgrade.

Before the Upgrade After the Upgrade

Cabinet door assembly (with a Cabinet door assembly (with a breathable film, a fan,
breathable film, a door status sensor, a door status sensor, a temperature sensor, and a
and a temperature sensor) PGND cable for the door)

AFMU (with a support) CMUEA assembly (including a support, an ELU, and


the CMUEA)

Fan assembly (including a support, a Fan assembly (including a support, a fan, and a fan
fan, and a fan interface board) on the interface board) on the top of the cabinet interior
top of the cabinet interior

APMI assembly (including a support Filler panel


and the APMI)

PSU4890 (including the PSUs and EPU05-0X (including the PMU and PSUs)
PMU) and PDU

3.3.1 Front Door


The front door of the cabinet consists of a door frame, a breathable film, fans, a temperature
sensor, a magnet of the door status sensor, and a PGND cable. These components have been
assembled before delivery. The door frame and breathable film are newly developed. Others
components are reused.
The following figure shows the structure of the front door.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 137


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-16 Components of the front door


No. Component Description

1 Magnet of a door The door status sensor reports the door status.
status sensor It consists of a switch and a magnet. The switch is
located on an inner wall of the cabinet and will not be
removed during the upgrade. The magnet is located
on the front door (as shown in the preceding figure)
and will be removed with the door. A new magnet will
be delivered with a new door.

2 Fans in the front door The fans on the top of the cabinet interior are reused.
They dissipate heat from the cabinet.

3 Door frame -

4 Breathable film It is newly developed for heat exchanging and


dissipation.

5 Temperature sensor It monitors the environmental temperature of the


cabinet.

6 Ground screw It connects the equipotential cable to the inner wall of


the cabinet.

3.3.2 Door Status Sensor


A door status sensor is used for monitoring the cabinet door status, whether open or closed.
The door status sensor consists of a magnet and a switch. The magnet is located on the door of
the cabinet, and the switch is located on the top right side of the cabinet interior.
There is a door status sensor in an APM or a TMC. The following figure shows the door status
sensor in an APM.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 138


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-25 Door status sensor

3.3.3 Temperature Sensors


The temperature sensor on the door of the cabinet is an environmental temperature sensor. It
monitors the environmental temperature outside the cabinet and reports it to the CMUEA.
There is also a temperature sensor near the air exhaust vent on the right side of the fan assembly,
which is located on the top of the cabinet interior, as shown in the following figure. This
temperature sensor monitors the internal temperature of the cabinet.

Figure 3-26 Positions of the temperature sensors

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 139


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

3.3.4 CMUEA Assembly


The CMUEA assembly is a central monitoring unit. It is used for monitoring and reporting the
type of the cabinet.

CMUEA Assembly
The CMUEA assembly consists of the CMUEA, ELU, and a support.
l The following figure shows the CMUEA components in the APM30 and TMC.

Figure 3-27 CMUEA components

(1) Central Monitoring Unit Type EA (CMUEA) (2)ELU

l The following figure shows the CMUEA components in the RFC.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 140


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-28 CMUEA components

(1) Support (2) Central Monitoring Unit Type EA (CMUEA)

For details about the ports and indicators on the CMUEA, see Central Monitoring Unit
Type EA (CMUEA).

Central Monitoring Unit Type EA (CMUEA)


The central monitoring unit type EA (CMUEA) mainly monitors the fans, heater, and cabinet
temperature. The CMUEA can be used in an AMP30H, RFC, TMC11H, IBBS200D, or
IBBS200T.

Exterior
Figure 3-29 shows the exterior of a CMUEA.

Figure 3-29 Exterior of a CMUEA

Ports
Figure 3-30 shows the ports on a CMUEA.

Figure 3-30 Ports on a CMUEA

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 141


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-17 describes the ports on a CMUEA.

Table 3-17 Ports on a CMUEA


No Port Remarks
.

(1) TEMP2 Reserved port, connected to the temperature sensor

(2) WATER Connected to the water sensor

(3) IFAN4 Connected to the inner circulation fan for the cabinet

(4) IFAN3 Connected to the inner circulation fan for the cabinet

(5) IFAN2 Connected to the inner circulation fan for the cabinet

(6) IFAN1 Connected to the inner circulation fan for the cabinet

(7) TEC Connected to the TEC cooler to receive alarms related to the TEC cooler

(8) TEMP1 l In the RFC, this port is connected to the temperature sensor at the air
intake vent of the cabinet to receive temperature alarms.
l In the IBBS200D or IBBS200T, this port is connected to the
temperature sensor to receive battery temperature alarm signals.

(9) COM_OUT RS485 signal port. It communicates with lower-level cascading ports
and reports monitoring information.
l In the APM30H, this port is connected to the PMU.
l In the RFC, TMC11H, or IBBS200D/IBBS200T, this port is
connected to the lower-level CMUEA.

(10 COM_IN RS485 signal port. It communicates with upper-level cascading ports
) and reports monitoring information.
l In the APM30H, this port is connected to the BBU.
l In the RFC or TMC11H, this port is connected to the BBU or an
upper-level CMUEA.
l In the IBBS200T, this port is connected to the PMU or upper-level
CMUEA.

(11 RUN Indicating the running status of the fans


) indicator

(12 ALM Indicating the alarm status of the fans


) indicator

(13 ELU Port connected to the ELU to report the cabinet type
)

(14 GATE Boolean signal port connected to the door status sensor
)

(15 IN0, IN1, Reserved Boolean signal port


) and IN2

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 142


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No Port Remarks
.

(16 SMOKE Boolean signal port connected to the smoke sensor


)

(17 EFAN1 Connected to the outer circulation fan for the cabinet
)

(18 EFAN2 Connected to the outer circulation fan for the cabinet
)

(19 PWR Power input port providing DC power input for the board
)

Indicators
Table 3-18 describes the indicators on the CMUEA.

Table 3-18 Indicators on the CMUEA


Silkscr Color Status Meaning
een

RUN Green Blinking (on for 1s and The board is functional and communicating
off for 1s) with the BBU properly.

Blinking (on for 0.125s The board is functional but fails to


and off for 0.125s) communicate with the BBU or the board is
not registered.

Steady on The board is in the power-on self-check


status.

Steady off The board is faulty.

ALM Red Steady off No alarm has been reported.

Steady on Alarms are generated, and the board must be


replaced.

Blinking (on for 1s and An alarm is generated, and the alarm may be
off for 1s) caused by an associated board or port fault.
Therefore, you need to locate the fault before
determining whether to replace the board.

DIP Switch
On the CMUEA, there is a DIP switch J18, which is used to set the working mode of the CMUEA
according to the cabinet type. Figure 3-31 shows the position of a DIP switch on the CMUEA.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 143


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-31 Position of a DIP switch on the CMUEA

In different types of cabinet, the DIP switch on the CMUEA is set in different ways, as shown
in Figure 3-32.

Figure 3-32 DIP switch setting on the CMUEA in different cabinets

NOTE
The white boxes indicate the positions of all bits in the DIP switch.

ELU
The electronic label unit (ELU) reports the cabinet type automatically to facilitate
troubleshooting.
The ELU is located on the CMUEA, as shown in the following figure.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 144


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-33 Exterior of an ELU

(1) Central Monitoring Unit Type EA (CMUEA) (2)ELU

3.3.5 Fan Assembly on the Top of the Cabinet Interior


The fan assembly on the top of the cabinet interior consists of the support, fan, and fan interface
board. The support is newly developed. The fan and fan interface board are reused.
The following figure shows the components of the fan assembly on the top of the cabinet interior.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 145


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-34 Components of the fan assembly on the top of the cabinet interior

No. Component Description

1 Fan The original fan is reused. It


dissipates heat from the
cabinet.

2 Fan interface board The original fan interface


board is reused. It connects to
cables and facilitates
maintenance of the fan.

3.3.6 DCDU-12B
A direct current distribution unit-12B (DCDU-12B) is 1 U high and provides DC power for all
components in the cabinet.

Exterior
Figure 3-35 and Figure 3-36 show exterior of a DCDU-12B.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 146


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-35 Front view of a DCDU-12B

(1) DC input terminal (2) DC output terminal (3) Spare fuse box (4) Ground point

Figure 3-36 Rear view of a DCDU-12B

(1) Ground point

NOTE
The DCDU-12B uses the equipotential connection point and ground point in the following scenarios:
l Scenario 1: The DCDU-12B is installed on an open subrack. An equipotential cable connects the
equipotential connection point near the mounting ear of the DCDU-12B to the ground bar of the open
rack.
l Scenario 2: The DCDU-12B is installed on a wall as a standalone power distribution device. The ground
point at the rear of the DCDU-12B is connected to the ground bar in the cabinet.

Functions
The DCDU-12B provides ten -48 V DC outputs using same fuse configurations to meet the
power distribution requirements of different distributed base stations.

Table 3-19 describes the DC power distribution functions of the DCDU-12B.

Table 3-19 DC power distribution functions of the DCDU-12B

DCDU Type DC output Power- Specificatio Remarks


ports Consuming n of the
Device Fuse

DCDU-12B LOAD0 to RRU0 to RRU5 30 A l BTS3900


LOAD5 l BTS3900A
LOAD6 BBU or l DBS3900
transmission l Mini NodeB
device

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 147


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

DCDU Type DC output Power- Specificatio Remarks


ports Consuming n of the
Device Fuse

LOAD7 BBU or
transmission
device

LOAD8 EMUA or
transmission
device

LOAD9 Fan assembly

NOTE
It is recommended that the power output terminals on the DCDU-12B be connected as follows:
l The LOAD0 to LOAD5 terminals are connected to cables with a cross-sectional area of 3.3mm2 (0.005
in.2) to 10mm2 (0.015 in.2) to provide power for RRU 0 to RRU 5.
l The LOAD6 to LOAD8 terminals are connected to cables with a cross-sectional area of 1.5mm2 (0.002
in.2) to 4mm2(0.006 in.2) to provide power for RRU 6 to RRU 8.
l The LOAD9 terminal is reserved.

Ports
Figure 3-37 shows the ports on the DCDU-12B panel.

Figure 3-37 Ports on the DCDU-12B panel

Table 3-20 shows the terminals and switches on the DCDU-12B panel.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 148


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-20 Terminals and switches on the DCDU-12B panel


N Port Silkscreen Matched Terminal Remarks
o. and Cable

(1) DC input NEG(-) One-hole OT Negative power input wiring


terminals terminal (M6) with terminal
two inputs. The
RTN(+) maximum cross- Positive power input wiring
sectional area of the terminal
cable is 35 mm2
(0.054 in.2) in one
input or 25 mm2
(0.039 in.2)in two
inputs. The default
cross-sectional area
is 16 mm2 (0.025 in.
2).

(2) Fuse LOAD0 to - It controls ports LOAD0 to


block LOAD9 LOAD9, and therefore controls
the power supplies to the BBU,
fan assemblies, and
transmission equipment.
The indicator on the fuse block
indicates the status of the fuse.
l When the indicator is steady
on, the fuse is faulty and
needs to be replaced.
l When the indicator is steady
off, the fuse is working
properly.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 149


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

N Port Silkscreen Matched Terminal Remarks


o. and Cable

(3) DC LOAD0 to l Figure 3-38 For the specifications of the DC


output LOAD9 shows the EPC5 output, see Table 3-19.
ports connectors for
ports LOAD0 to
LOAD5. The
cross-sectional
area of the cable is
3.3mm2 (0.005 in.
2) to 10mm2

(0.015 in.2).
l Figure 3-39
shows an EPC4/
EPC6 connector,
which applies to
any one among
ports LOAD6 to
LOAD9. The
cross-sectional
area of the cable is
1.5mm2 (0.002 in.
2) to 4mm2(0.006

in.2).
NOTE
Figure 3-39 shows an
EPC4 or EPC6
connector. An EPC4
connector must be
connected to a cable
onsite, whereas an
EPC6 connector has
been connected to a
cable before delivery.
The EPC5 connector
must be connected to
the cable onsite.

NOTE
Fuse blocks and DC output terminals are jointly called fuse terminal blocks.

Figure 3-38 Exterior of an EPC5 connector

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 150


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-39 Exterior of an EPC4 or EPC6 connector

Technical Specifications
Table 3-21 lists the technical specifications of a DCDU-12B.

Table 3-21 Technical specifications of a DCDU-12B


Item Specifications

Dimensions (H x W x D) The DCDU-12B is 1 U high and can be


installed in a 19-inch cabinet or rack. Its
dimensions are as follows:
l 42 mm x 442 mm x 65 mm (1.65 in. x 17.4
in. x 2.56 in.) (without mounting ears)
l 42 mm x 482.6 mm x 65 mm (1.65 in. x
19 in. x 2.56 in.) (with mounting ears)

Surge Protection Specifications -48 V DC power port, 10 kA (8/20 μs)


differential mode

-48 V DC power port, 20 kA (8/20 μs)


common mode

3.3.7 DCDU-12C
A direct current distribution unit-12C (DCDU-12C) is 1 U high and provides DC power input
for all components in the cabinet.

Exterior
Figure 3-40 shows the DCDU-12C.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 151


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-40 Front view of a DCDU-12C

(1) DC input terminal (2) DC output terminal (3) Spare fuse box (4) Ground point

Functions
The DCDU-12C provides ten -48 V DC outputs using same fuse configurations to meet the
power distribution requirements of distributed and separated base stations

Table 3-22 describes the DC power distribution functions of a DCDU-12C.

Table 3-22 DC power distribution functions of a DCDU-12C

DCDU Type DC output Power- Specificatio Remarks


ports Consuming n of the
Device Fuse

DCDU-12C LOAD0 Transmission 30 A l BTS3900A (-48


device V)
l Transmission
LOAD1 Transmission
cabinet
device

LOAD2 Transmission
device

LOAD3 Transmission
device

LOAD4 Transmission
device

LOAD5 Transmission
device

LOAD6 BBU or
transmission
device

LOAD7 BBU or
transmission
device

LOAD8 EMUA or
transmission
device

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 152


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

DCDU Type DC output Power- Specificatio Remarks


ports Consuming n of the
Device Fuse

LOAD9 Fan assembly

Ports
Figure 3-41 shows the ports on the DCDU-12C panel.

Figure 3-41 Ports on the DCDU-12C panel

Table 3-23 describes the ports on the DCDU-12C panel.

Table 3-23 Ports on the DCDU-12C panel


N Port Silkscreen Matched Terminal Remarks
o. and Cable

(1) DC input NEG(-) Two one-hole OT Negative power input wiring


terminals terminals (M6). The terminal
cross-sectional area
RTN(+) of the cable is 25 Positive power input wiring
mm2 (0.039) by terminal
default.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 153


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

N Port Silkscreen Matched Terminal Remarks


o. and Cable

(2) Fuse LOAD0 to - It controls ports LOAD0 to


block LOAD9 LOAD9, and therefore controls
the power supplies to the BBU,
fan assemblies, and
transmission equipment.
The indicator on the fuse block
indicates the status of the fuse.
l When the indicator is steady
on, the fuse is faulty and
needs to be replaced.
l When the indicator is steady
off, the fuse is working
properly.

(3) DC LOAD0 to Figure 3-42 shows For the specifications of the DC


output LOAD9 an EPC4/EPC6 output, see Table 3-22.
ports connector, which
applies to any one
among ports LOAD0
to LOAD9. The
cross-sectional area
of the cable is
1.5mm2 (0.002 in.2)
to 4mm2(0.006 in.2).

NOTE
Fuse blocks and DC output terminals are jointly called fuse terminal blocks.

Figure 3-42 Exterior of an EPC4 or EPC6 connector

Technical Specifications
Table 3-24 lists the technical specifications of a DCDU-12C.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 154


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-24 Technical specifications of a DCDU-12C


Item Specifications

Dimensions (H x W x D) The DCDU-12C is 1 U high and can be


installed in a 19-inch cabinet or rack. Its
dimensions are as follows:
l 42 mm x 442 mm x 65 mm (1.65 in. x 17.4
in. x 2.56 in.) (without mounting ears)
l 42 mm x 482.6 mm x 65 mm (1.65 in. x
19 in. x 2.56 in.) (with mounting ears)

Surge Protection Specifications -48 V DC power port, 10 kA (8/20 μs)


differential mode

-48 V DC power port, 20 kA (8/20 μs)


common mode

3.4 RFC Components to Be Replaced During the Upgrade


During the RFC hardware upgrade, the following components need to be replaced: the
DCDU-13A, CMUEA, and fan assembly.
The following table describes the RFC components to be replaced during the upgrade.

Before the Upgrade After the Upgrade

DCDU-02 DCDU-13A

FMEA assembly (including a support CMUEA assembly (including a support and the
and the FMEA) CMUEA)

Fan assembly (including a case and Fan assembly (including a case and the fans)
the fans)

Filler panel ELU assembly (including a support and an ELU)

3.4.1 DCDU-13A
A direct current distribution unit-13A (DCDU-13A) is 1 U high and provides DC power for all
components in the cabinet.

Exterior
The following figure shows the exterior of a DCDU-13A.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 155


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-43 Exterior of a DCDU-13A

Function
The DCDU-13A has the following functions:
l Supports -48 V DC input.
l Provides four -48 V DC power outputs for other boards or modules in the cabinet.
l Provides surge protection of 10 kA in differential mode and 20 kA in common mode and
dry contacts for reporting the surge protection failure alarm.

Ports
The following figure shows the ports on the DCDU-13A panel.

Figure 3-44 Ports on the DCDU-13A panel

No. Port Silkscree Matched Terminal Description


n and Cable

1 Dry contact DC_SPD - Dry contact alarm


output port output port

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 156


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No. Port Silkscree Matched Terminal Description


n and Cable

2 DC output ports LOAD0 to EPC4 connector (as l The LOAD0 to


LOAD3 shown in the LOAD3 ports on
following figure) the left
DCDU-13A in
the cabinet
provide power for
the CMUEA and
RFU 0 to RFU 2.
l The LOAD0 to
LOAD2 ports on
the right
DCDU-13A in
the cabinet
provide power for
RFU 3 to RFU 5.
The LOAD3 port
is reserved.

3 DC input NEG(-) Two one-hole OT It is a negative power


terminals terminals (M6). The input terminal.
maximum cross-
RTN(+) sectional area of the It is a positive power
single cable is 35 input terminal.
mm2 (0.054 in.2) and
each maximum cross-
sectional area of the
two pairs of cables is
16 mm2 (0.025 in.2).
The default cross-
sectional area is 25
mm2 (0.039 in.2).

Figure 3-45 EPC4 connector

3.4.2 CMUEA Assembly


The CMUEA assembly is a central monitoring unit. It is used for monitoring and reporting the
type of the cabinet.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 157


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

CMUEA Assembly
The CMUEA assembly consists of the CMUEA, ELU, and a support.

l The following figure shows the CMUEA components in the APM30 and TMC.

Figure 3-46 CMUEA components

(1) Central Monitoring Unit Type EA (CMUEA) (2)ELU

l The following figure shows the CMUEA components in the RFC.

Figure 3-47 CMUEA components

(1) Support (2) Central Monitoring Unit Type EA (CMUEA)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 158


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

For details about the ports and indicators on the CMUEA, see Central Monitoring Unit
Type EA (CMUEA).

Central Monitoring Unit Type EA (CMUEA)


The central monitoring unit type EA (CMUEA) mainly monitors the fans, heater, and cabinet
temperature. The CMUEA can be used in an AMP30H, RFC, TMC11H, IBBS200D, or
IBBS200T.

Exterior
Figure 3-48 shows the exterior of a CMUEA.

Figure 3-48 Exterior of a CMUEA

Ports
Figure 3-49 shows the ports on a CMUEA.

Figure 3-49 Ports on a CMUEA

Table 3-25 describes the ports on a CMUEA.

Table 3-25 Ports on a CMUEA


No Port Remarks
.

(1) TEMP2 Reserved port, connected to the temperature sensor

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 159


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No Port Remarks
.

(2) WATER Connected to the water sensor

(3) IFAN4 Connected to the inner circulation fan for the cabinet

(4) IFAN3 Connected to the inner circulation fan for the cabinet

(5) IFAN2 Connected to the inner circulation fan for the cabinet

(6) IFAN1 Connected to the inner circulation fan for the cabinet

(7) TEC Connected to the TEC cooler to receive alarms related to the TEC cooler

(8) TEMP1 l In the RFC, this port is connected to the temperature sensor at the air
intake vent of the cabinet to receive temperature alarms.
l In the IBBS200D or IBBS200T, this port is connected to the
temperature sensor to receive battery temperature alarm signals.

(9) COM_OUT RS485 signal port. It communicates with lower-level cascading ports
and reports monitoring information.
l In the APM30H, this port is connected to the PMU.
l In the RFC, TMC11H, or IBBS200D/IBBS200T, this port is
connected to the lower-level CMUEA.

(10 COM_IN RS485 signal port. It communicates with upper-level cascading ports
) and reports monitoring information.
l In the APM30H, this port is connected to the BBU.
l In the RFC or TMC11H, this port is connected to the BBU or an
upper-level CMUEA.
l In the IBBS200T, this port is connected to the PMU or upper-level
CMUEA.

(11 RUN Indicating the running status of the fans


) indicator

(12 ALM Indicating the alarm status of the fans


) indicator

(13 ELU Port connected to the ELU to report the cabinet type
)

(14 GATE Boolean signal port connected to the door status sensor
)

(15 IN0, IN1, Reserved Boolean signal port


) and IN2

(16 SMOKE Boolean signal port connected to the smoke sensor


)

(17 EFAN1 Connected to the outer circulation fan for the cabinet
)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 160


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No Port Remarks
.

(18 EFAN2 Connected to the outer circulation fan for the cabinet
)

(19 PWR Power input port providing DC power input for the board
)

Indicators
Table 3-26 describes the indicators on the CMUEA.

Table 3-26 Indicators on the CMUEA


Silkscr Color Status Meaning
een

RUN Green Blinking (on for 1s and The board is functional and communicating
off for 1s) with the BBU properly.

Blinking (on for 0.125s The board is functional but fails to


and off for 0.125s) communicate with the BBU or the board is
not registered.

Steady on The board is in the power-on self-check


status.

Steady off The board is faulty.

ALM Red Steady off No alarm has been reported.

Steady on Alarms are generated, and the board must be


replaced.

Blinking (on for 1s and An alarm is generated, and the alarm may be
off for 1s) caused by an associated board or port fault.
Therefore, you need to locate the fault before
determining whether to replace the board.

DIP Switch
On the CMUEA, there is a DIP switch J18, which is used to set the working mode of the CMUEA
according to the cabinet type. Figure 3-50 shows the position of a DIP switch on the CMUEA.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 161


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-50 Position of a DIP switch on the CMUEA

In different types of cabinet, the DIP switch on the CMUEA is set in different ways, as shown
in Figure 3-51.

Figure 3-51 DIP switch setting on the CMUEA in different cabinets

NOTE
The white boxes indicate the positions of all bits in the DIP switch.

3.4.3 Fan Assembly


A fan assembly dissipates heat from the cabinet. It contains two standalone fans.

Exterior
The following figure shows the structure of a fan assembly.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 162


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-52 Structure of the fan assembly

(1) Fans (2) Fan support

3.4.4 ELU Assembly


An ELU assembly consists of an electronic label unit (ELU) and an ELU support. The ELU
reports the cabinet type automatically to facilitate troubleshooting.
The following figure shows the structure of the ELU assembly.

Figure 3-53 ELU assembly

(1) ELU (2) Panel (3) RJ45 port

3.5 BBC Components to Be Replaced During the Upgrade


During the BBC hardware upgrade, the following components need to be replaced: positive and
negative wiring terminals for storage batteries, circuit breaker for the storage battery group, and
positive and negative power input terminals for the storage battery group.
The following table describes the BBC components to be replaced during the upgrade.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 163


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-54 BBC components to be replaced during the upgrade

(1) Negative power input terminal for (2) Positive power input terminal for (3) Circuit breaker for the storage
the storage battery group the storage battery group battery group

The following table describes the BBC components to be replaced during the upgrade.

Table 3-27 BBC components to be replaced during the upgrade


Before the Upgrade After the Upgrade

Negative/positive wiring terminals (25 mm2 Negative/positive wiring terminals (35 mm2
or 0.039 in.2, with an M6 OT terminal) for or 0.054 in.2, with an M6 OT terminal) for
storage batteries storage batteries

Circuit breaker for the storage battery group Circuit breaker for the storage battery group
(circuit breaker of 1 P/80 A) (circuit breaker of 2 P/100 A)

NOTE
P is short for Pole, indicating the number of switches simultaneously controlled by a pole.

3.6 Auxiliary Equipment


This section describes the auxiliary equipment to be replaced during the hardware upgrade from
APM30H (Ver.A) series cabinets to APM30H (Ver.D) series cabinets. The auxiliary equipment
includes the Signal Lightning Protection Unit (SLPU), Outdoor Fiber Distribution, 6 (OFD06),
Outdoor Distribution Module DC, 6 (ODM06D-3).

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 164


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

3.6.1 SLPU
The signal lightning protection unit (SLPU), which can be optionally configured with the UFLP,
UELP, or USLP2, provides the signal surge protection.

SLPU
The SLPU, which has a case structure, is 19 inches wide and 1 U high.
Figure 3-55 shows the SLPU.

Figure 3-55 SLPU

Slot Assignment Rules for the SLPU


This section describes the slot assignment rules for the SPLU boards.

Slots of the SLPU


Figure 3-56 shows the slots of the SLPU.

Figure 3-56 SLPU slots

Slot Assignment Rules for the SLPU


When the SLPU is used as a trunk signal protection unit, a mandatory component, it can be
integrated with UELP or UFLP and is installed in the 1 U space in the upper part of the cabinet.
Table 3-28 lists the slot assignment rules of the SLPU.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 165


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-28 Slot assignment rules for the SLPU

Board Optional or Maximum Slot Remarks


Mandatory Quantity

UELP Optional 4 Slot 0 to slot 3 The UELP is


installed, in
descending
order of priority,
in slot 2, 0, 1, or
3.

UFLP Optional 1 Slot 3 If both the


UELP and
UFLP are
configured, the
UFLP is
installed in a slot
with a higher
priority than the
UELP.

When there are not more than 16 dry contacts in the SLPU, the SLPU is used as a monitoring
signal protection unit, which is an optional component. In this case, the SLPU is integrated with
two USLP2s and installed in the 1 U (44.45 mm or 1.75 in.) space at the bottom of the BBU.
Table 3-29 lists the slot assignment rules for the SLPU.

Table 3-29 Slot assignment rules for the SLPU

Board Optional or Quantity Slot Remarks


Mandatory

USLP2 Optional 2 Slot 2 and slot 3 -

UELP
Each universal E1/T1 lightning protection unit (UELP) provides surge protection for four paths
of E1/T1 signals.

Panel
Figure 3-57 shows the panel of the UELP.

Figure 3-57 UELP panel

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 166


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Ports
Table 3-30 lists the ports on the UELP.

Table 3-30 Ports on the UELP

Silkscreen Connector Description

INSIDE DB25 female connector Connecting to a transmission


board of the base station

OUTSIDE DB26 female connector Connecting to an external


transmission device

DIP Switch
The UELP has one DIP switch, which is used to determine whether the receiving end is grounded.
The DIP switch has four DIP bits. Figure 3-58 shows the DIP switch on the UELP.

Figure 3-58 DIP switch on the UELP

Table 3-31 describes the DIP switch on the UELP.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 167


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-31 DIP switch on the UELP

DIP DIP Status Description


Switch
1 2 3 4

S1 OFF OFF OFF OFF Not grounded

Other status Grounded

NOTE
The E1 cable of 75 ohms can be either grounded or not, whereas the E1 cable of 120 ohms and the T1 cable
of 100 ohms cannot be grounded.

UFLP
Each universal FE lightning protection unit (UFLP) provides protection for two channels of FE
signals. Each universal FE lightning protection unit type B (UFLPB) provides protection for two
channels of FE/GE signals.

NOTE
The UFLPB applies only to the LTE mode.

Panel
Figure 3-59 shows the UELP panel.

Figure 3-59 UELP panel

Figure 3-60 shows the UFLPB panel.

Figure 3-60 UFLPB panel

Port
Table 3-32 describes UFLP ports.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 168


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-32 UFLP ports

Port Location Silkscreen Connector Description

INSIDE side FE0 and FE1 RJ45 connector Connecting to a


transmission board of the
base station

OUTSIDE side FE0 and FE1 RJ45 connector Connecting to an external


transmission device

Table 3-33 describes UFLPB ports.

Table 3-33 UFLPB ports

Port Location Silkscreen on the Connector Description


Panel

INSIDE side FE/GE0 and FE/GE1 RJ45 connector Connecting to a


transmission board
of the base station

OUTSIDE side FE/GE0 and FE/GE1 RJ45 connector Connecting to an


external
transmission device

USLP2
The Universal Signal Lightning Protection Unit Type 2 (USLP2) is a dry contact surge protection
unit. It is optional and can be installed in the SLPU.

Panel
Figure 3-61 shows the panel of a USLP2.

Figure 3-61 Panel of a USLP2

Port
There are four input ports and two output ports on the USLP2. Table 3-34 lists the ports on the
panel of the USLP2.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 169


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-34 Ports on the panel of the USLP2

Silkscreen on Port Type Quantity Description


the Panel

IN0, IN1, IN2, 4-pin 4 Input ports, which


and IN3 connect to customized
alarm devices

OUT0 and OUT1 RJ45 connector 2 Output ports, which


connect to an EXT-
ALM port of the UPEU
or UEIU in the cabinet

Figure 3-62 shows the mapping relationship between the pins in the input and output ports on
the USLP2.

Figure 3-62 Mapping relationship between the pins in the input and output ports on the USLP2
OUT0 OUT1 IN0 IN1 IN2 IN3
7 5 3 1 7 5 3 1 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
8 6 4 2 8 6 4 2

Table 3-35 lists the mapping relationship between the pins in the input and output ports on the
USLP2.

Table 3-35 Mapping relationship between the pins in the input and output ports on the USLP2

Input Output

Silkscreen on the Pin Silkscreen on the Pin


Panel Panel

INO IN0.1 OUT1 OUT1.1

IN0.2 OUT1.2

IN0.3 OUT1.4

IN0.4 OUT1.5

IN1 IN1.1 OUT1.3

IN1.2 OUT1.6

IN1.3 OUT1.7

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 170


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Input Output

Silkscreen on the Pin Silkscreen on the Pin


Panel Panel

IN1.4 OUT1.8

IN2 IN2.1 OUT0 OUT0.1

IN2.2 OUT0.2

IN2.3 OUT0.4

IN2.4 OUT0.5

IN3 IN3.1 OUT0.3

IN3.2 OUT0.6

IN3.3 OUT0.7

IN3.4 OUT0.8

For details about the application of the USLP2, see Slot Assignment Rules for the SLPU.

3.6.2 OFD06
The Outdoor Fiber Distribution 6 (OFD06) distributes fiber optic cables on the RRU side.

Exterior
The following figure shows the OFD06 exterior.

Figure 3-63 OFD06 exterior

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 171


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Function
The OFD06 performs the following functions:
l Distributes fiber optic cables on the RRU side.
l Can be installed flexibly. The OFD06 can be installed on an outdoor wall, metal pole and
tower.

Interior
The following figure shows the OFD06 interior.

Figure 3-64 OFD06 interior

(1) Box (2) Optical fiber distribution and (3) Optical fiber routed-in area
storage area

(4) Fiber optic cables (connected to the (5) (6) Outdoor fiber optic jumpers
Indoor Fiber Distribution) (connected to RRUs)

Specifications
The following table lists the OFD06 specifications.

Table 3-36 OFD06 specifications

Item Specifications

Dimensions (H x W x D) 270 mm x 278 mm x 100 mm (10.63 in. x


10.94 in. x 3.94 in.)

Weight 2.5 kg (5.51 lb)

Operating temperature -40°C to 55°C (-40°F to 131°F)

Storage temperature -50ºC to 70ºC (-58°F to 158°F)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 172


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Item Specifications

Relative humidity ≤ 95%

Operating environment Outdoor

IP level IP65

INPUT (core) 1x12 cores

OUTPUT (core) 6x2 cores (connected to six RRUs)

Adapter DLC

Mounted type Pole or wall

Maintenance Front maintenance

Insert loss ≤ 0.3 dB

Return loss ≥ 45 dB

Fireproof level UL94 V0

3.6.3 ODM06D-3
The Outdoor Distribution Module DC 6 (ODM06D-3) performs functions such as power
distribution and surge protection. It provides surge protection for outdoor RRUs.

Exterior
The following figure shows the ODM06D-3 exterior.

Figure 3-65 ODM06D-3 exterior

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 173


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Function
The ODM06D-3 performs the following functions:
l Provides surge protection for outdoor RRUs.
l Provides one or two power inputs and six power outputs.
l Reports the surge protection failure alarm.

Interior
The following figure shows the ODM06D-3 interior.

Figure 3-66 ODM06D-3 interior

(1) Cover plate of the housing (2) Cable connector making label (3) Protective cover (4) Circuit breakers

(5) Surge protector (6) Cord end terminal bar (7) Clip

Specifications
The following table lists the specifications of the ODM06D-3.

Table 3-37 Specifications

Item Specification

Dimensions (H x W x D) 369 mm x 278.5 mm x 98.5 mm (14.53 in. x


10.96 in. x 3.88 in.)

Weight 4.0 kg (8.82 lb)

Color Light Gray RAL 7035 white

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 174


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Item Specification

Power inputs and outputs One or two inputs and six outputs

Safety IEC/EN60950-1 and IEC/EN60950-22

IP level IP65

Certification CE

Mounted type Pole and wall

Lightning protection alarm Dry connector

Operating temperature -40°C to 55°C (-40ºF to 131ºF)

Storage temperature -40ºC to +70ºC (-40ºF to +158ºF)

Relative humidity ≤ 95%

DC input connection -48 V and RTN (cord end terminal)

Input voltage range -48 V DC normal (-57 V DC to -36 V DC)

Maximum input current 100 A

Diameter range of input power cables 18 mm to 25 mm (0.71 in. to 0.98 in.)

DC output connection -48 V and RTN (cord end terminal)

Rated current 32 A

Output power distribution Six outputs connected to RRUs

Output power cable grounding Six grounded outputs

Diameter range of output power cables 9 mm to 14 mm (0.35 in. to 0.55 in.)

3.7 BTS3900A&DBS3900 Cables


This section describes the PGND cables, power cables, and signal cables that need to be installed
or maintained after the BTS3900A&DBS3900 hardware upgrade.

3.7.1 BTS3900A Cable List


BTS3900A cables consist of the PGND cables, power cables, and signal cables.

NOTE
Transmission cables in the BTS3900A need to be reused and the reused transmission cables are connected
to the original positions. For details about transmission cable connections in the BTS3900A, see BTS3900A
GSM Hardware Description (with Breathable Film).

Power Cables and PGND Cables


The following table describes the power cables and PGND cables after the hardware upgrade.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 175


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Equipotential OT terminal l Ground OT terminal l Front door of


Cable for the point on an the APM30
Front Door inner wall of l Front door of
the APM30 the TMC
l Ground
point on an
inner wall of
the TMC

Input Power OT terminal AC INPUT Depending on External power


Cables for the terminal on the the external equipment
APM30 EPU in the power
APM30 equipment

Input Power EPC4 connector LOAD7 port on OT terminal RTN(+) and


Cable for the the EPU in the NEG(-)
TMC (in AC APM30 terminals on the
Scenarios) DCDU-12C in
the TMC

Input Power Depending on External power OT terminal RTN(+) and


Cable for the the external equipment NEG(-)
TMC (in DC power terminals on the
Scenarios) equipment DCDU-12C in
the TMC

Input Power OT terminal RFC1 terminal OT terminal RTN(+) and


Cable for the on the EPU in NEG(-)
RFC (in AC the APM30 terminals on the
Scenarios) left DCDU-13A
in the RFC

Input Power OT terminal RTN(+) and Depending on External power


Cable for the NEG(-) the external equipment
RFC (in DC terminals on the power
Scenarios) left DCDU-13A equipment
in the RFC

RFU Power EPC4 connector LOAD0 to 3V3 connector PWR port on


Cables LOAD2 ports any of RFU0 to
on the left RFU2 in the
DCDU-13A in RFC
the RFC

LOAD0 to PWR port on


LOAD2 ports any of RFU3 to
on the right RFU5 in the
DCDU-13A in RFC
the RFC

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 176


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Power Cables OT terminal l NEG(-) OT terminal l NEG(-)


Between terminal on terminal on
Cascaded the left the right
DCDU-13As DCDU-13A DCDU-13A
in the RFC in the RFC
l RTN(+) l RTN(+)
terminal on terminal on
the left the right
DCDU-13A DCDU-13A
in the RFC in the RFC

Storage Battery OT terminal BAT terminal OT terminal Wiring copper


Power Cable on the EPU in bar for the
the APM30 positive and
negative poles
of storage
batteries

BBU Power EPC4 connector LOAD0 and 3V3 connector -48V port on the
Cable (in AC LOAD1 ports UPEU in the
Scenarios) on the EPU in BBU in the
the APM30 APM30 or TMC

BBU Power EPC4 connector LOAD6 and 3V3 connector -48V port on the
Cable (in DC LOAD7 ports UPEU in the
Scenarios) on the BBU in the
DCDU-12C in TMC
the TMC

Input Power OT terminal 8-pin transfer Cord end Transfer


Cable for the terminal on the terminal terminal on the
Heater EPU in the heater
APM30

Power Cable OT terminal 8-pin transfer OT terminal Wiring terminal


for the Heating terminal on the for the input
Film EPU in the power cable for
APM30 the heating film
in the BBC

CMUEA EPC4 connector LOAD2 port on 3V3 connector PWR port on the
Power Cable the EPU in the CMUEA in the
APM30 APM30

LOAD9 port on PWR port on the


the DCDU-12C CMUEA in the
in the TMC TMC

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 177


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

LOAD3 port on PWR port on the


the left CMUEA in the
DCDU-13A in RFC
the RFC

EMUA Power EPC4 connector LOAD5 port on Cord end PWR1 terminal
Cable the EPU in the terminal on the EMUA
(Optional) APM30

LOAD8 port on
the DCDU-12C
in the TMC

Signal Cables
The following table describes the signal cables after the hardware upgrade.

Cable One End The Other End

Connector Installation Connector Installation


Position Position

CMUEA-BBU RJ45 connector COM_IN port RJ45 connector MON1 port on


Monitoring on the CMUEA the UPEU in the
Signal Cable in the APM30 BBU in the
APM30

COM_IN port MON0 port on


on the CMUEA the UPEU in the
in the RFC BBU in the
APM30

Monitoring Bare wire Door status 2-pin connector GATE port on


Signal Cable sensor the PMU in the
for the Door APM30
Status Sensor
in the APM30

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 178


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Monitoring OT terminal When an 2-pin connector TEM_BAT port


Signal Cable external battery on the PMU in
for the cabinet is used, the APM30
Temperature this cable is
Sensor in the bound to the
Battery cable bridge on
Cabinet the left side of
the upper
compartment in
the battery
cabinet.

Monitoring 4-pin connector l TEMP1 port 5-pin connector l Port on the


Signal Cable on the environment
for the CMUEA in al
Temperature the APM30 temperature
Sensor l TEMP2 port sensor in the
on the APM30
CMUEA in l Port on the
the APM30 temperature
l TEMP1 port sensor near
on the the air
CMUEA in exhaust vent
the RFC in the
APM30
l Port on the
environment
al
temperature
sensor in the
RFC

Monitoring 4-pin connector IFAN1 and 4-pin connector J01 and J02
Signal IFAN2 ports on ports on the fan
Transfer Cable the CMUEA interface board
for the Fan on
the Top of the
Cabinet
Interior

ELU Signal RJ45 connector ELU on the RJ45 connector ELU


Cable CMUEA

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 179


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Monitoring Bare wire l GATE port Bare wire Door status


Signal Cable on the sensor
for the Door CMUEA in
Status Sensor the TMC
l GATE port
on the
CMUEA in
the RFC

Monitoring Interconnection l Power cable 4-pin connector l EFAN1 and


Signal terminal for the fan in EFAN2
Transfer Cable the front ports on the
for the Fan in door of the CMUEA in
the Front Door APM30 the APM30
l Power cable l EFAN1 and
for the fan in EFAN2
the front ports on the
door of the CMUEA in
TMC the TMC

Surge Bare wire l DC_SPD Bare wire l IN0 port on


Protection port on the the CMUEA
Alarm Cable left in the RFC
for the DCDU-13A l IN1 port on
DCDU-13A in the RFC the CMUEA
l DC_SPD in the RFC
port on the
right
DCDU-13A
in the RFC

PMU-CMUEA RJ45 connector COM_IN port RJ45 connector COM_OUT


Monitoring on the PMU port on the
Signal Cable CMUEA

Monitoring RJ45 connector COM_OUT RJ45 connector COM_IN port


Signal Cable port on the on the lower-
Between upper-level level CMUEA
Cascaded CMUEA
CMUEAs

EMUA DB9 male RS485 port on RJ45 connector COM_OUT


Monitoring connector the EMUA in port on the PMU
Signal Cable the APM30 in the APM30
(Optional)
RS485 port on COM_OUT
the EMUA in port on the
the TMC CMUEA in the
TMC

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 180


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

RF Cables
The following table describes the RF cables after the hardware upgrade.

NOTE

l When a Bias Tee is configured, the jumpers use DIN straight male connectors. After the cabinet is
upgraded, the Bias Tee needs to be removed, and therefore the DIN straight male connectors need to
be replaced by DIN elbow male connectors.
l When a Bias Tee is not configured before the upgrade, the original jumpers can be reused during the
upgrade.

Cable One End The Other End

Connector Installation Connector Installation


Position Position

RF jumpers DIN straight Antenna feeder DIN elbow male ANT_TX/RXA


male connector connector and ANT_RXB
ports on an RFU

3.7.2 DBS3900 Cable List


DBS3900 cables consist of the PGND cables, power cables, and signal cables.

NOTE
Transmission cables in the DBS3900 need to be reused and the reused transmission cables are connected
to the original positions. For details about transmission cable connections in the DBS3900, see DBS3900
Hardware Description.

Power Cables and PGND Cables


The following table describes the power cables and PGND cables after the hardware upgrade.

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Equipotential OT terminal l Ground OT terminal l Front door of


Cable for the point on an the APM30
Front Door inner wall of l Front door of
the APM30 the TMC
l Ground
point on an
inner wall of
the TMC

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 181


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Input Power OT terminal AC INPUT Depending on External power


Cables for the terminal on the the external equipment
APM30 EPU in the power
APM30 equipment

Input Power EPC4 connector LOAD7 port on OT terminal RTN(+) and


Cable for the the EPU in the NEG(-)
TMC (in AC APM30 terminals on the
Scenarios) DCDU-12C in
the TMC

Input Power Depending on External power OT terminal RTN(+) and


Cable for the the external equipment NEG(-)
TMC (in DC power terminals on the
Scenarios) equipment DCDU-12B in
the TMC

Storage Battery OT terminal BAT terminal OT terminal Wiring copper


Power Cable on the EPU in bar for the
the APM30 positive and
negative poles
of storage
batteries

BBU Power EPC4 connector LOAD0 and 3V3 connector -48V port on the
Cable (in AC LOAD1 ports UPEU in the
Scenarios) on the EPU in BBU in the
the APM30 APM30 or TMC

BBU Power EPC4 connector LOAD6 and 3V3 connector -48V port on the
Cable (in DC LOAD7 ports UPEU in the
Scenarios) on the BBU in the
DCDU-12C in TMC
the TMC

Input Power OT terminal 8-pin transfer Cord end Transfer


Cable for the terminal on the terminal terminal on the
Heater EPU in the heater
APM30

Power Cable OT terminal 8-pin transfer OT terminal Wiring terminal


for the Heating terminal on the for the input
Film EPU in the power cable for
APM30 the heating film
in the BBC

CMUEA EPC4 connector LOAD2 port on 3V3 connector PWR port on the
Power Cable the EPU in the CMUEA in the
APM30 APM30

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 182


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

LOAD9 port on PWR port on the


the DCDU-12C CMUEA in the
in the TMC TMC

EMUA Power EPC4 connector LOAD5 port on Cord end PWR1 terminal
Cable the EPU in the terminal on the EMUA
(Optional) APM30

LOAD8 port on
the DCDU-12C
in the TMC

Signal Cables
The following table describes the signal cables after the hardware upgrade.

Cable One End The Other End

Connector Installation Connector Installation


Position Position

CMUEA-BBU RJ45 connector COM_IN port RJ45 connector MON1 port on


Monitoring on the CMUEA the UPEU in the
Signal Cable in the APM30 BBU in the
APM30

Monitoring Bare wire Door status 2-pin connector GATE port on


Signal Cable sensor the PMU in the
for the Door APM30
Status Sensor
in the APM30

Monitoring OT terminal When an 2-pin connector TEM_BAT port


Signal Cable external battery on the PMU in
for the cabinet is used, the APM30
Temperature this cable is
Sensor in the bound to the
Battery cable bridge on
Cabinet the left side of
the upper
compartment in
the battery
cabinet.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 183


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Monitoring 4-pin connector l TEMP1 port 5-pin connector l Port on the


Signal Cable on the environment
for the CMUEA in al
Temperature the APM30 temperature
Sensor l TEMP2 port sensor in the
on the APM30
CMUEA in l Port on the
the APM30 temperature
sensor near
the air
exhaust vent
in the
APM30

Monitoring 4-pin connector IFAN1 and 4-pin connector J01 and J02
Signal IFAN2 ports on ports on the fan
Transfer Cable the CMUEA interface board
for the Fan on
the Top of the
Cabinet
Interior

ELU Signal RJ45 connector ELU on the RJ45 connector ELU


Cable CMUEA

Monitoring Bare wire GATE port on Bare wire Door status


Signal Cable the CMUEA in sensor
for the Door the TMC
Status Sensor

Monitoring Interconnection l Power cable 4-pin connector l EFAN1 and


Signal terminal for the fan in EFAN2
Transfer Cable the front ports on the
for the Fan in door of the CMUEA in
the Front Door APM30 the APM30
l Power cable l EFAN1 and
for the fan in EFAN2
the front ports on the
door of the CMUEA in
TMC the TMC

PMU-CMUEA RJ45 connector COM_IN port RJ45 connector COM_OUT


Monitoring on the PMU port on the
Signal Cable CMUEA

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 184


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Cable One End The Other End

Connector Installation Connector Installation


Position Position

Monitoring RJ45 connector COM_OUT RJ45 connector COM_IN port


Signal Cable port on the on the lower-
Between upper-level level CMUEA
Cascaded CMUEA
CMUEAs

EMUA DB9 male RS485 port on RJ45 connector COM_OUT


Monitoring connector the EMUA in port on the PMU
Signal Cable the APM30 in the APM30
(Optional)
RS485 port on COM_OUT
the EMUA in port on the
the TMC CMUEA in the
TMC

3.7.3 Cable Connections


The power cable connections and signal cable connections in the BTS3900A and DBS3900 vary
according to the power supply scenarios, cabinet configurations, and transmission system.

Power Cable Connections in a BTS3900A


This section describes the power cable connections in a BTS3900A supplied with 110 V AC,
220 V AC, and -48 V DC power to facilitate power cable installation and maintenance.

Power Cable Connections in a 110 V AC or 220 V AC Input Scenario


NOTE
If a device is not configured, ignore the power cable connections for the device in the figures showing
power cable connections.

When a BTS3900A is supplied with 110 V AC or 220 V AC power, 1 APM30+1 TMC+1 BBC
+2 RFCs are configured. The following figure shows the power cable connections.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 185


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-67 Power cable connections in a base station configured with 1 APM30+1 TMC+1
BBC+2 RFCs

The following table describes the power cable connections.

Table 3-38 Power cable connections in a base station configured with 1 APM30+1 TMC+1
BBC+2 RFCs
No. Description

P1 Input power cables for the APM30

P2 and P9 CMUEA power cable

P3 and P16 to P18 Power cables for the battery cabinet

P4 Input power cable for the RFC

P5 BBU power cable

P6 EMUA power cable

P7 Input power cable for the TMC

P8 Power cable between cascaded DCDU-13As

P10 to P15 RFU power cables

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 186


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Power Cable Connections in a -48 V DC Input Scenario


The following figure shows the power cable connections in a BTS3900A configured with 1 TMC
+2 RFCs in a -48 V DC input scenario.

Figure 3-68 Power cable connections in a base station configured with 1 TMC+2 RFCs

The following table describes the power cable connections.

Table 3-39 Power cable connections in a base station configured with 1 TMC+2 RFCs
No. Description

P0 Input power cable for the TMC

P1 and P5 CMUEA power cable

P2 BBU power cable

P3 EMUA power cable

P4 Input power cable for the RFC

P6 to P11 RFU power cables

Monitoring Signal Cable Connections in a BTS3900A


This section describes the monitoring signal cable connections in a BTS3900A in 110 V or 220
V AC and -48 V DC scenarios.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 187


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Monitoring Signal Cable Connections in the 110 V or 220 V AC Scenario


When a BTS3900A is in the configuration of 1 APM30+1 TMC+1 BBC+2 RFCs and is supplied
with 110 V or 220 V AC power, the monitoring signal cable connections are shown in the
following figure.

Figure 3-69 Monitoring signal cable connections in the configuration of 1 APM30+1 TMC+1
BBC+2 RFCs

The following table describes the monitoring signal cable connections.

Table 3-40 Monitoring signal cable connections in the configuration of 1 APM30+1 TMC+1
BBC+2 RFCs
No. Description

S0 Monitoring Signal Cable for the Door


Status Sensor in the APM30

S1 Monitoring Signal Cable for the


Temperature Sensor for Storage Batteries

S2 Monitoring Signal Cable Between Cascaded


CMUEAs

S3 Monitoring Signal Cable for the EMUA

S4 Monitoring Signal Transfer Cable for the


Fan at the Top of a Cabinet

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 188


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No. Description

S5, S15, and S20 Monitoring Signal Cable for the


Temperature Sensor

S6 and S14 ELU Signal Cable

S7 and S8 CMUEA-BBU Monitoring Signal Cable

S9 and S17 Monitoring Signal Cable Between Cascaded


CMUEAs

S10 and S16

S11 and S12 Surge Protection Alarm Cable for the


DCDU-13A

S13 and S18 Monitoring Signal Cable for the Door


Status Sensor

S19 Monitoring Signal Transfer Cable for the


Fan in the Front Door

Monitoring Signal Cable Connections in the -48 V DC Scenario


When a BTS3900A is in the configuration of 1 TMC+2 RFCs and is supplied with -48 V DC
power, the monitoring signal cable connections are shown in the following figure.

Figure 3-70 Monitoring signal cable connections in the configuration of 1 TMC+2 RFCs

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 189


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

The following table describes the monitoring signal cable connections.

Table 3-41 Monitoring signal cable connections in the configuration of 1 TMC+2 RFCs
No. Description

S0 and S13 Monitoring Signal Cable for the Door


Status Sensor

S1 Monitoring Signal Transfer Cable for the


Fan in the Front Door

S2 Monitoring Signal Cable for the EMUA

S3, S5, and S15 Monitoring Signal Cable for the


Temperature Sensor

S4 Monitoring Signal Transfer Cable for the


Fan at the Top of a Cabinet

S6 and S14 ELU Signal Cable

S7 and S8 CMUEA-BBU Monitoring Signal Cable

S9 Monitoring Signal Cable Between Cascaded


CMUEAs

S10 and S16

S11 and S12 Surge Protection Alarm Cable for the


DCDU-13A

Power Cable Connections in a DBS3900


This section describes the power cable connections in a DBS3900 supplied with 110 V AC, 220
V AC, and -48 V DC power to facilitate power cable installation and maintenance.

Power Cable Connections in a 110 V AC or 220 V AC Input Scenario


NOTE
If a device is not configured, ignore the power cable connections for the device in the figures showing
power cable connections.

When a DBS3900 is supplied with 110 V AC or 220 V AC power, 1 APM30+1 TMC+1 BBC
are configured. The following figure shows the power cable connections.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 190


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-71 Power cable connections in a base station configured with 1 APM30+1 TMC+1
BBC

The following table describes the power cable connections.

Table 3-42 Power cable connections in a base station configured with 1 APM30+1 TMC+1
BBC

No. Description

P1 Input power cables for the APM30

P2 CMUEA power cable

P3 and P8 to P10 Power cables for the battery cabinet

P4 Input power cable for the RFC

P5 BBU power cable

P6 EMUA power cable

P7 Input power cable for the TMC

Power Cable Connections in a -48 V DC Input Scenario


The following figure shows the power cable connections in a DBS3900 configured with 2 TMCs
in a -48 V DC input scenario.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 191


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-72 Power cable connections in a base station configured with two TMCs

The following table describes the power cable connections.

Table 3-43 Power cable connections in a base station configured with two TMCs
No. Description

P0 Input power cable for the TMC

P1 CMUEA power cable

P2 BBU power cable

P3 EMUA power cable

Monitoring Signal Cable Connections in a DBS3900


This section describes the monitoring signal cable connections in a DBS3900 in 110 V or 220
V AC and -48 V DC scenarios.

Monitoring Signal Cable Connections in the 110 V or 220 V AC Scenario


When a DBS3900 is in the configuration of 1 APM30+1 TMC+1 BBC and is supplied with 110
V or 220 V AC power, the monitoring signal cable connections are shown in the following figure.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 192


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-73 Monitoring signal cable connections in the configuration of 1 APM30+1 TMC+1
BBC

The following table describes the monitoring signal cable connections.

Table 3-44 Monitoring signal cable connections in the configuration of 1 APM30+1 TMC+1
BBC

No. Description

S0 Monitoring Signal Cable for the Door


Status Sensor in the APM30

S1 Monitoring Signal Cable for the


Temperature Sensor for Storage Batteries

S2 Monitoring Signal Cable Between Cascaded


CMUEAs

S3 Monitoring Signal Cable for the EMUA

S4 Monitoring Signal Transfer Cable for the


Fan at the Top of a Cabinet

S5 and S10 Monitoring Signal Cable for the


Temperature Sensor

S6 ELU Signal Cable

S7 and S8 CMUEA-BBU Monitoring Signal Cable

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 193


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No. Description

S9 Monitoring Signal Transfer Cable for the


Fan in the Front Door

S11 and S12 Monitoring Signal Cable for the Door


Status Sensor

Monitoring Signal Cable Connections in the -48 V DC Scenario


When a DBS3900 is in the configuration of two TMCs and is supplied with -48 V DC power,
the monitoring signal cable connections are shown in the following figure.

Figure 3-74 Monitoring signal cable connections in the configuration of two TMCs

The following table describes the monitoring signal cable connections.

Table 3-45 Monitoring signal cable connections in the configuration of two TMCs

No. Description

S0 Monitoring Signal Cable for the Door


Status Sensor

S1 Monitoring Signal Transfer Cable for the


Fan in the Front Door

S2 Monitoring Signal Cable for the EMUA

S3 and S5 Monitoring Signal Cable for the


Temperature Sensor

S4 Monitoring Signal Transfer Cable for the


Fan at the Top of a Cabinet

S6 Monitoring Signal Cable Between Cascaded


CMUEAs

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 194


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

No. Description

S7 and S8 CMUEA-BBU Monitoring Signal Cable

3.7.4 Equipotential Cable


An equipotential cable connects the PGND terminals of two cabinets. It ensures equipotential
bonding between the cabinets and the safe operation of base stations.

Exterior
The following figure shows the exterior of an equipotential cable.
NOTE

When 110 V AC dual-live-wire power is supplied for the cabinet, a green equipotential cable is used.

Figure 3-75 Exterior of an equipotential cable

(1) OT terminal

Description
The following table describes an equipotential cable.

Table 3-46 Equipotential cable

Cable Color Size of the OT Terminal and Cross-


Sectional Area of the Wire

Equipotential cable Green and yellow M6, 16 mm2 (0.025 in.2)


for the cabinet

3.7.5 Power Cables


This chapter describes power cables in the BTS3900A (Ver.D2_A1) and DBS3900
(Ver.D2_A1).

CMUEA Power Cable


A CMUEA power cable feeds power into the CMUEA.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 195


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Exterior
A CMUEA power cable has a 3V3 connector at one one and an EPC4 connector at the other
end, as shown in the following figure.

Figure 3-76 CMUEA power cable

(1) 3V3 connector (2) EPC4 connector

Description
A CMUEA power cable consists of two wires. The following table describes the pin assignment
for the wires of a CMUEA power cable.

Table 3-47 Pin assignment for the wires of a CMUEA power cable
Wire X1 End X2 End

W1 X1.A1 X2.2

W2 X1.A3 X2.1

BBU Power Cable


A BBU power cable feeds power into a BBU. The maximum length of a BBU power cable is
20 m (0.79 in.).

Exterior
A BBU power cable has a 3V3 connector at one end and a EPC4 or EPC6 connector at the other
end, as shown in Figure 3-77 and Figure 3-78.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 196


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-77 Exterior of a BBU power cable (1)

(1) 3V3 connector (2) EPC4 or EPC6 connector

Figure 3-78 Exterior of a BBU power cable (2)

(1) 3V3 connector (2) EPC4 or EPC6 connector

Table 3-48 lists the specifications of the cable.

Table 3-48 Specifications of the input power cable for BBU power cable

Cable Wire Wire Color in Most Wire Color in Other


Regions Regions (UK)

BBU power cable RTN(+) Black Blue

NEG(-) Black Gray

Pin Assignment
A BBU power cable consists of two wires. Table 3-49 describes the pin assignment for the wires
of a BBU power cable.

Table 3-49 Pin assignment for the wires of a BBU power cable

Wire X1 End X2 End

W1 X1.A1 X2.2

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 197


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Wire X1 End X2 End

W2 X1.A3 X2.1

RFU Power Cable


An RFU power cable feeds -48 V DC power into an RFU.

Exterior
An RFU power cable has a 3V3 connector at one end and a EPC4 or EPC6 connector at the other
end, as shown in Figure 3-79 and Figure 3-80.

Figure 3-79 Exterior of an RFU power cable (1)

(1) 3V3 connector (2) EPC4 or EPC6 connector

Figure 3-80 Exterior of a RFU power cable (2)

(1) 3V3 connector (2) EPC4 or EPC6 connector

Table 3-50 lists the specifications of the cable.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 198


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-50 Specifications of the input power cable for RFU power cable

Cable Wire Wire Color in Most Wire Color in Other


Regions Regions (UK)

RFU power cable RTN(+) Black Blue

NEG(-) Black Gray

Pin Assignment
An RFU power cable consists of two wires. Table 3-51 describes the pin assignment for the
wires of a RFU power cable.

Table 3-51 Pin assignment for the wires of an RFU power cable

Wire X1 End X2 End

W1 X1.A1 X2.2

W2 X1.A3 X2.1

Power Cables for the Battery Cabinet


This section describes the input power cable for the battery cabinet, power cable between the
storage battery group and the wiring copper bar, and copper bar between the storage batteries.

Exterior
Figure 3-81 shows the exterior of an input power cable for the battery cabinet. The maximum
length of an input power cable for the battery cabinet is 5 m (16.40 ft).

Figure 3-81 Exterior of an input power cable for the battery cabinet

(1) OT terminal (M8, 35 mm2 or 0.054 in.2 [UL3436])

NOTE
One end of the input power cable is connected to the power input terminal for the storage battery group,
and the other end is connected to the EPU in the APM30.

Figure 3-82 shows a cable between the storage battery group and the wiring copper bar.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 199


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-82 Cable between the storage battery group and the wiring copper bar

(1) OT terminal (M8, 35 mm2 or 0.054 in.2 [UL3436]) (2) OT terminal (M6, 35 mm2 or 0.054 in.2 [UL3436])

NOTE
The M6 OT terminal is connected to the storage battery, and the M8 OT terminal is connected to the power
cable terminal for the storage battery group.

Copper bars between batteries are delivered with batteries. The following figure shows a copper
bar between the storage batteries.

Figure 3-83 Copper bar between the storage batteries

Specifications
l The RTN(+) wire of an input power cable for the storage battery is a red wire with a cross-
sectional area of 35 mm2 (0.054 in.2), and the NEG(-) wire is a black wire with a cross-
sectional area of 35 mm2 (0.054 in.2).
l The RTN(+) wire of the power cable between the storage battery group and wiring copper
bar is a red wire with a cross-sectional area of 35 mm2 (0.054 in.2), and the NEG(-) wire
is a black wire with a cross-sectional area of 35 mm2 (0.054 in.2).

Input Power Cables for the APM30


An input power cable for the APM30 feeds external AC power into the power system of the
APM30. The cabinet can be configured with different power systems to support power supplies
of 220 V AC single-phase, 220 V AC three-phase, and 110 V or 220 V dual-live-wire.

Exterior
The following figure shows the exterior of a 220 V AC single-phase input power cable.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 200


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-84 Exterior of a 220 V AC single-phase input power cable

(1) OT terminal

NOTE

Different types of AC input power cables consist of different numbers of core wires. The preceding figure
shows the inner structure of a 220 V AC single-phase input power cable.

Description
The following table describes different types of AC input power cables.

Table 3-52 Description of AC input power cables

Cable Wire Wire Color Size of the OT


Terminal and Cross-
Sectional Area of the
Wire

220 V AC three- L1 wire Brown M6, 6mm2 (0.006 in.2)


phase power cable
L2 wire Black

L3 wire Gray

N wire Blue

220 V AC single- L wire Brown M6, 25 mm2 (0.039 in.2)


phase power cable
N wire Blue

110 V AC dual- L1 wire Black M6, 25 mm2 (0.039 in.2)


live-wire
L2 wire Red

N wire White

NOTE

The colors and structures of cables delivered by Huawei vary according to countries and areas. If cables
are purchased at local markets, the cables must comply with local rules and regulations.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 201


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Input Power Cable for the TMC


The type of input power cable for the TMC depends on the power supply to the TMC.

Input Power Cable for the TMC (1)


In a BTS3900A or DBS3900 supplied with AC power, the TMC is powered by the APM30, and
the maximum length of the input power cable is 15 m (49.21 ft) or 10 m (32.81 ft). The following
figure shows the exterior of an input power cable for the TMC.

Figure 3-85 Input power cable for the TMC (1)

(1) EPC4 or EPC6 connector (2) OT terminal

The following table describes an input power cable for the TMC.

Table 3-53 Input power cable for the TMC (1)

Cable Wire Wire Color Size of the OT Terminal


and Cross-Sectional Area
of the Wire

Input power cable RTN(+) Black M6, 4 mm2 (0.006 in.2)


for the TMC (1)
NEG(-) Blue

Input Power Cable for the TMC (2)


In a BTS3900A or DBS3900 using -48 V DC power, if the TMC is powered by the external
power device, the maximum length of the input power cable is 10 m (32.81 ft). The following
figure shows the exterior of an input power cable for the TMC.

Figure 3-86 Input power cable for the TMC (2)

(1) OT terminal

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 202


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

The following table describes an input power cable for the TMC.

Table 3-54 Input power cable for the TMC (2)


Cable Wire Wire Color Size of the OT Terminal
and Cross-Sectional Area
of the Wire

Input power cable RTN(+) Black M6, one pair of wires with a
for the TMC (2) cross-sectional area of 35
NEG(-) Blue mm2 (0.054 in.2), two pairs
of wires with a cross-
sectional area of 16 mm2
(0.025 in.2)

Input Power Cable for the TMC (3)


When the TMC is used as a transmission cabinet, the specifications of its power cable are as
follows:
In a BTS3900A or DBS3900 using -48 V DC power, if the TMC is powered by the external
power device, the maximum length of the input power cable is 15 m (49.21 ft) or 10 m (32.81
ft). Figure 3-87 shows the exterior of an input power cable for the TMC.

Figure 3-87 Input power cable for the TMC (3)

(1) OT terminal (M6, 4 mm2 or 0.006 in.2)

Input Power Cable for the RFC


An input power cable for the RFC feeds -48 V DC power into the left DCDU-13A in the RFC,
and the -48 V DC power is then distributed to the RFC.

NOTE

The RFCs configured for the BTS3900A in different scenarios are supplied with different types of power,
and use different input power cables.

Input Power Cable for the RFC in AC Scenarios


When a BTS3900A is supplied with AC power, the RFC is powered by the EPU in the APM30,
and the input power cable is connected from the APM30 to the left DCDU-13A in the RFC.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 203


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

The following figure shows an input power cable from the APM30 to the RFC.

Figure 3-88 Input power cable for the RFC in AC scenarios

(1) OT terminal (2) OT terminal

The following table describes an input power cable for the RFC in AC scenarios.

Table 3-55 Input power cable for the RFC in AC scenarios


Cable Wire Wire Color in Wire Color in Size of the OT
Most Regions Other Regions Terminal and
Cross-Sectional
Area of the Wire

Input power RTN Black Blue M6, 25 mm2 (0.039


cable for the (+) in.2)
RFC in AC
scenarios NEG Blue Gray
(-)

Input Power Cable for the RFC in DC Scenarios


When a BTS3900A is supplied with -48 V DC power, the RFC is powered by the external power
equipment, and the input power cable is connected from the external power equipment to the
left DCDU-13A in the RFC.
The following figure shows the input power cable from the external power equipment to the left
DCDU-13A in the RFC.

Figure 3-89 Input power cable for the RFC in DC scenarios

(1) OT terminal

The following table describes an input power cable for the RFC in DC scenarios.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 204


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

NOTE
An input power cable for the RFC in DC scenarios supports two types of power supplies: 1x160 A and
2x80 A, and one group of 35 mm 2 (0.054 in. 2) cables or two groups of 16 mm 2 (0.025 in. 2) cables can
be used. Each group of cable consists of two wires: RTN(+) and NEG(-).

Table 3-56 Input power cable for the RFC in DC scenarios


Cable Wire Wire Color in Wire Color in Size of the OT
Most Regions Other Regions Terminal and
Cross-Sectional
Area of the Wire

Input power RTN Black Blue M6, 35 mm2 (0.54 in.


cable for the (+) 2)
RFC
NEG Blue Gray
(-)

Input power RTN Black Blue M6, 16 mm2 (0.025


cable for the (+) in.2)
RFC
NEG Blue Gray
(-)

Power Cable Between Cascaded DCDU-13As


When both the RFC and APM30 are used, the RFC is configured with two DCDU-13As. The
APM30 supplies one input to the left DCDU-13A, and the right DCDU-13A is cascaded with
the left DCDU-13A.
The following figure shows the exterior of a power cable between cascaded DCDU-13As.

Figure 3-90 Power cable between cascaded DCDU-13As

(1) OT terminal

The following table describes a power cable between cascaded DCDU-13As.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 205


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Table 3-57 Power cable between cascaded DCDU-13As


Cable Wire Wire Color in Wire Color in Size of the OT
Most Regions Other Regions Terminal and
Cross-Sectional
Area of the Wire

Power cable RTN Black Blue M6, 25 mm2 (0.039


between (+) in.2)
cascaded
DCDU-13As NEG Blue Gray
(-)

Input Power Cable for the Heater


An input power cable for the heater connects the AC output terminal on the EPU in the APM30
to the transfer terminal on the heater.
The following figure shows an input power cable for the heater in the APM30.

Figure 3-91 Input power cable for the heater

(1) OT terminal (M4, 1 mm2 or 0.002 in.2) (2) Cord end terminal

Power Cable for the Heating Film


A power cable for the heating film connects the AC output terminal on the EPU in the APM30
to the AC power input terminal on the heating film.

A power cable for the heating film, whose cross-sectional area is 1 mm2 (0.002 in.2), has a black
jacket and contains a blue wire and a brown wire, as shown in the following figure.

Figure 3-92 Exterior of a power cable for the heating film

(1) OT terminal (M4, 1 mm2 or 0.002 in.2)

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 206


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

NOTE
The colors and structures of cables delivered by Huawei vary according to countries and areas. If cables
are purchased locally, the cables must comply with local rules and regulations.

Power Cable for the EMUA


A power cable for the EMUA leads -48 V DC power to the EMUA.

Exterior
Figure 3-93 shows a power cable for the EMUA.

Figure 3-93 Power cable for the EMUA

(1) Tool-less female connector (pressfit type) (2) Cord end terminal

Cable Specification
Table 3-58 describes the specifications of the power cable for the EMUA.

Table 3-58 Specifications of the power cable for the EMUA

Cable Wire Wire Color in Most Wire Color in Other Area


Area

Power cable for the RTN(+) Black Blue


EMUA
NEG(-) Blue Gray

3.7.6 Signal Cables


This chapter describes all signal cables in a BTS3900A (Ver.D2_A1) and a DBS3900
(Ver.D2_A1).

CMUEA-BBU Monitoring Signal Cable


A CMUEA-BBU monitoring signal cable connects the CMUEA and the BBU and transmits the
monitoring signals collected by the CMUEA to the BBU.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 207


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Exterior
Figure 3-94 shows a CMUEA-BBU monitoring signal cable.

Figure 3-94 Exterior of a CMUEA-BBU monitoring signal cable

(1) RJ45 connector

Pin Assignment
Table 3-59 describes the pin assignment for the wires of a CMUEA-BBU monitoring signal
cable.

Table 3-59 Pin assignment for the wires of a CMUEA-BBU monitoring signal cable
X1 End X2 End Wire Color Type

X1.1 X2.1 White Twisted pair

X1.2 X2.2 Orange

X1.3 X2.3 White Twisted pair

X1.6 X2.6 Green

X1.5 X2.5 White Twisted pair

X1.4 X2.4 Blue

X1.7 X2.7 White Twisted pair

X1.8 X2.8 Brown

Monitoring Signal Cable for the Door Status Sensor in the APM30
A monitoring signal cable for the door status sensor in the APM30 transmits the alarm signals
from the door status sensor to the PMU, and the PMU reports the alarms to the BBU.
The following figure shows the exterior of a monitoring signal cable for the door status sensor
in the APM30.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 208


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-95 Monitoring signal cable for the door status sensor in the APM30

The description of a monitoring signal cable for the door status sensor in the APM30 is as follows:
l Cable 1 has a 2-pin straight socket at one end, which is connected to the GATE port on the
PMU. Cable 1 has a bare wire and a cord end terminal at the other end, which are connected
to a door status sensor and a cable terminal block, respectively.
l Cable 2 has a bare wire at one end, which is connected to a door status sensor. Cable 2 has
a cord end terminal at the other end, which is connected to a cable terminal block.

Monitoring Signal Cable for the Temperature Sensor for Storage Batteries
A monitoring signal cable transmits the temperature information of storage batteries to the PMU.

The following figure shows the exterior of a monitoring signal cable for the temperature sensor
for storage batteries.

Figure 3-96 Monitoring signal cable for the temperature sensor for storage batteries

(1) OT terminal (2) 2-pin connector

Monitoring Signal Cable for the Temperature Sensor


A monitoring signal cable for the temperature sensor transmits the temperature signals to the
central monitoring unit type EA (CMUEA). One end of the cable is connected to the temperature
sensor and the other end is connected to the port on the CMUEA.

The following figure shows the exterior of a monitoring signal cable for the temperature sensor.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 209


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-97 Monitoring signal cable for the temperature sensor

(1) 4-pin connector (2) 5-pin connector

An ambient temperature sensor and a temperature sensor at the air intake vent are installed in
an APM30. Therefore, two monitoring signal cables are required. For the positions of the
temperature sensors, see 3.2.3 Temperature Sensors.
An ambient temperature sensor is installed in an RFC. Therefore, one monitoring signal cable
is required.

Monitoring Signal Transfer Cable for the Fan at the Top of a Cabinet
A monitoring signal transfer cable for the fan at the top of a cabinet feeds power into the fan at
the top of the APM30 or TMC and transmits monitoring signals to the CMUEA.
The following figure shows the exterior of a monitoring signal transfer cable for fan at the top
of a cabinet

Figure 3-98 Monitoring signal transfer cable for the fan at the top of a cabinet

(1) 4-pin connector

ELU Signal Cable


The electronic label unit (ELU) signal cable is used by the ELU to report the cabinet type to the
central monitoring unit type EA (CMUEA).

Exterior
Figure 3-99 shows the exterior of an ELU signal cable.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 210


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-99 Exterior of an ELU signal cable

(1) RJ45 connector

Cable Description
Table 3-60 describes the pin assignment for the wires of an ELU signal cable.

Table 3-60 Pin assignment for the wires of an ELU signal cable
X1 End X2 End Color Type

X1.1 X2.1 White Twisted pair

X1.2 X2.2 Orange

X1.3 X2.3 White Twisted pair

X1.6 X2.6 Green

X1.5 X2.5 White Twisted pair

X1.4 X2.4 Blue

X1.7 X2.7 White Twisted pair

X1.8 X2.8 Brown

Monitoring Signal Transfer Cable for the Fan in the Front Door
A monitoring signal transfer cable for the fan in the front door feeds power into the fan in the
front door of the APM30 or TMC and transmits fan monitoring signals to the CMUEA.

Exterior
The following figure shows the exteriors of a monitoring signal transfer cable for fan in the front
door.

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 211


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Figure 3-100 Monitoring signal transfer cable for the fan in the front door

(1) 4-pin connector (2) Interconnection terminal

Description
The following table describes a monitoring signal transfer cable for the fan in the front door.

Table 3-61 Pin assignment for the wires of a monitoring signal transfer cable for the fan in the
front door

Wire X1 End X2 End Color

W1 X1.1 X2.1 Black

W2 X1.2 X2.2 Black

W3 X1.3 X2.3 Black

W4 X1.4 X2.4 Black

Monitoring Signal Cable for the Door Status Sensor


A monitoring signal cable for the door status transmits the door status obtained from the door
status sensor in a TMC or BBC to the CMUEA.

The monitoring signal cable for a door status sensor consists of two parts, both of which have a
bare wire at each end, as shown in the following figure.

Figure 3-101 Monitoring signal cable for the door status sensor

Surge Protection Alarm Cable for the DCDU-13A


A surge protection alarm cable for the DCDU-13A transmits surge protection dry contact alarm
signals of the DCDU-13A to the CMUEA. The maximum length of a surge protection alarm
cable for the DCDU-13A is 0.8 m (31.50 in.).

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 212


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Both ends of a surge protection alarm cable for the DCDU-13A are bare wires, as shown in the
following figure.

Figure 3-102 Surge protection alarm cable for the DCDU-13A

PMU-CMUEA Monitoring Signal Cable


The PMU-CMUEA monitoring signal cable transmits the RS485 signals collected by the PMU
to the BBU through the CMUEA. This monitoring signal cable is 1.1 m (3.61 ft) long.

Exterior
The monitoring signal cable is black and has an RJ45 connector at each end, as shown in Figure
3-103.

Figure 3-103 Exterior of a monitoring signal cable

(1) RJ45 connector

Cable Description
Table 3-62 describes the pin assignment for the wires of a monitoring signal cable.

Table 3-62 Pin assignment for the wires of a monitoring signal cable
X1 End X2 End Description

X1.1 X2.1 Twisted pair

X1.2 X2.2

X1.3 X2.3 Twisted pair

X1.6 X2.6

X1.4 X2.4 Twisted pair

X1.5 X2.5

X1.7 X2.7 Twisted pair

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 213


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

X1 End X2 End Description

X1.8 X2.8

Monitoring Signal Cable Between Cascaded CMUEAs


Cascaded CMUEAs are connected by signal cables. The lower-level CMUEA can communicate
with the BBU through the upper-level CMUEA.

Exterior
Figure 3-104 shows a monitoring signal cable between cascaded CMUEAs.

Figure 3-104 Exterior of a monitoring signal cable between cascaded CMUEAs

(1) RJ45 connector

Pin Assignment
Table 3-63 describes the pin assignment for the wires of the monitoring signal cable between
cascaded CMUEAs.

Table 3-63 Pin assignment for the wires of the monitoring signal cable between cascaded
CMUEAs

X1 End X2 End Wire Color Type

X1.1 X2.1 White Twisted pair

X1.2 X2.2 Orange

X1.3 X2.3 White Twisted pair

X1.6 X2.6 Green

X1.4 X2.4 White Twisted pair

X1.5 X2.5 Blue

X1.7 X2.7 White Twisted pair

X1.8 X2.8 Brown

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 214


Copyright © Huawei Technologies Co., Ltd.
BTS3900A & DBS3900 3 Upgrade from APM30 Series Cabinets to APM30H
Hardware Description for Enhanced Cabinets (Ver.D_A1) Series Cabinets

Monitoring Signal Cable for the EMUA


A monitoring signal cable for the EMUA transmits monitoring signals from an EMUA to a BBU.
This cable is delivered with the EMUA.

Exterior
Figure 3-105 shows the monitoring signal cable for the EMUA.

Figure 3-105 Monitoring signal cable for the EMUA

(1) RJ45 connector (2) DB9 male connector

Pin Assignment
Table 3-64 describes the pin assignment for the wires of the monitoring signal cable for the
EMUA.

Table 3-64 Pin assignment for the wires of the monitoring signal cable for the EMUA
Pin on the DB9 male Color Description Associated
RJ45 connector Port on the
Connector APMI

X1.1 X2.3 White Twisted pair TX+

X1.2 X2.7 Orange TX-

X1.5 X2.6 White Twisted pair RX-

X1.4 X2.2 Blue RX+

Issue 01 (2013-04-28) Huawei Proprietary and Confidential 215


Copyright © Huawei Technologies Co., Ltd.