4-2. Troubleshooting Procedures by Malfunction Code


∗ If a malfunction code is shown on the Touch Panel, reset the malfunction and then start the relevant
troubleshooting procedure.

1) C0000 : Fusing Motor M3's Failure to Turn


C0010 : PC Drum Drive Motor M2's Failure to Turn
Relevant Electrical Parts
Fusing Motor M3 Master Board PWB-A
PC Drum Drive Motor M2 Power Supply Board PWB-C

1155C06TAA

T-36
◆C0000
Step Check Item Result Action
1 Check M3 for operation. NO Change PWB-A.
Does the voltage across PJ7A-1A on PWB-
A and GND change from DC5V to DC0V
when the Start key is pressed?
2 Does the voltage across PJ7A-8A on PWB- NO Check gears for overload and, if they are
A and GND change from DC5V to DC0V okay, change M3.
when the Start key is pressed?
3 Is the voltage across PJ7C-6B on PWB-C YES Change PWB-A or M3.
and GND DC24V? NO Change PWB-C.

◆C0010
Step Check Item Result Action
1 Check M2 for operation. NO Change PWB-A.
Does the voltage across PJ7A-2A on PWB-
A and GND change from DC5V to DC0V
when the Start key is pressed?
2 Does the voltage across PJ7A-9A on PWB- NO Check gears for overload and, if they are
A and GND change from DC5V to DC0V okay, change M2.
when the Start key is pressed?
3 Is the voltage across PJ4C-5A on PWB-C YES Change PWB-A or M2.
and GND DC5V? Is the voltage across NO Change PWB-C.
PJ7C-5B on PWB-C and GND DC24V?

T-37
2) C0020 : Paper Take-Up Motor M21's Failure to Turn
C0040 : Suction Fan Motor M14's Failure to Turn
C0042 : Toner Suction Fan Motor M13's Failure to Turn
C0048 : Hard Disk Drive Cooling Fan Motor 1 M34's Failure to Turn, Hard Disk Drive Cooling Fan
Motor 2 M35's Failure to Turn
Relevant Electrical Parts
Paper Take-Up Motor M21 Master Board PWB-A
Suction Fan Motor M14 Drawer S/P Board PWB-F
Toner Suction Fan Motor M13
Hard Disk Drive Cooling Fan Motor 1 M34
Hard Disk Drive Cooling Fan Motor 2 M35

1155C07TAB

T-38
◆C0020
Step Check Item Result Action
1 Check M21 for operation. NO Change PWB-A or PWB-F.
Does the voltage across PJ2F-2 on PWB-F
and GND change from DC5V to DC0V
when the Start key is pressed?
2 Does the voltage across PJ2F-4 on PWB-F YES Change PWB-A or PWB-F.
and GND change from DC5V to DC0V NO Check gears for overload and, if they are
when the Start key is pressed? okay, change M21.

◆C0040
Step Check Item Result Action
1 Check M14 for operation. YES Change PWB-A.
Does the voltage across PJ3A-8B on PWB- NO Check gears for overload and, if they are
A and GND change from DC5V to DC0V okay, change M14.
when the malfunction is reset?

◆C0042
Step Check Item Result Action
1 Check M13 for operation. NO Change PWB-A.
Does the voltage across PJ2A-3B on PWB-
A and GND change from DC0V to DC24V
when the Start key is pressed?
2 Does the voltage across PJ2A-5B on PWB- YES Change PWB-A.
A and GND change from DC5V to DC0V NO Check gears for overload and, if they are
when the Start key is pressed? okay, change M13.

◆C0048
Step Check Item Result Action
1 Check M34 for operation. NO Check gears for overload and, if they are
Does the voltage across PJ3A-7A on PWB- okay, change M34.
A and GND change from DC5V to DC0V
when the malfunction is reset?
2 Check M35 for operation. YES Change PWB-A.
Does the voltage across PJ7A-12A on NO Check gears for overload and, if they are
PWB-A and GND change from DC5V to okay, change M35.
DC0V when the malfunction is reset?

T-39
3) C0049 : PH Cooling Fan Motor M19’s Failure to Turn
C004A: PC Drum Cooling Fan Motor M17’s Failure to Turn
Relevant Electrical Parts
PC Drum Cooling Fan Motor M17 PH Cooling Fan Motor M19
Master Board PWB-A
Power Supply Board PWB-C

1155C11TAB

T-40
◆C0049
Step Check Item Result Action
1 Check M19 for operation. NO Change PWB-A.
Does the voltage across PJ8A-12A on
PWB-A and GND change from DC0V to
DC24V when the Start key is pressed?
2 Does the voltage across PJ8A-11A on YES Change PWB-A.
PWB-A and GND change from DC5V to NO Check gears for overload and, if they are
DC0V when the Start key is pressed? okay, change M19.

◆C004A
Step Check Item Result Action
1 Check M17 for operation. NO Change PWB-A.
Does the voltage across PJ10A-6B on
PWB-A and GND change from DC0V to
DC24V when the malfunction is reset?
2 Does the voltage across PJ10A-4B on YES Change PWB-A.
PWB-A and GND change from DC5V to NO Check gears for overload and, if they are
DC0V when the malfunction is reset? okay, change M17.

T-41
4) C004B: CCD Cooling Fan Motor M32’s Failure To Turn
C004C: Ozone Ventilation Fan Motor M12's Failure to Turn
Relevant Electrical Parts
Ozone Ventilation Fan Motor M12 Master Board PWB-A
CCD Cooling Fan Motor M32 Power Supply Board PWB-C

1155C08TAB

T-42
◆C004B
Step Check Item Result Action
1 Check M32 for operation. NO Change PWB-A.
Does the voltage across PJ10A-9B on
PWB-A and GND change from DC0V to
DC24V when the malfunction is reset?
2 Does the voltage across PJ10A-11B on YES Change PWB-A.
PWB-A and GND change from DC5V to NO Check gears for overload and, if they are
DC0V when the malfunction is reset? okay, change M17.

◆C004C
Step Check Item Result Action
1 Check M12 for operation. NO Change PWB-A.
Does the voltage across PJ10A-7B on
PWB-A and GND change from about
DC16V to DC24V when the Start key is
pressed?
2 Does the voltage across PJ10A-5B on YES Change PWB-A.
PWB-A and GND change from DC5V to NO Check gears for overload and, if they are
DC0V when the malfunction is reset? okay, change M12.

T-43
5) C004D: Power Supply Unit Cooling Fan Motor 3 M18's Failure to Turn
C004E: Power Supply Unit Cooling Fan Motor 1 M15's Failure to Turn
Power Supply Unit Cooling Fan Motor 2 M16's Failure to Turn
Relevant Electrical Parts
Power Supply Unit Cooling Fan Motor 3 M18 Master Board PWB-A
Power Supply Unit Cooling Fan Motor 2 M16
Power Supply Unit Cooling Fan Motor 1 M15

1155C32TAB

T-44
◆C004D
Step Check Item Result Action
1 Check M18 for operation. NO Change PWB-A.
Does the voltage across PJ2A-13B on
PWB-A and GND change from DC0V to
DC24V when the malfunction is reset?
2 Does the voltage across PJ2A-15B on YES Change PWB-A.
PWB-A and GND change from DC5V to NO Check gears for overload and, if they are
DC0V when the malfunction is reset? okay, change M18.

◆C004E
Step Check Item Result Action
1 Check M15 for operation. NO Change PWB-A.
Does the voltage across PJ2A-6B on PWB-
A and GND change from DC0V to DC24V
when the Start key is pressed?
2 Does the voltage across PJ2A-8B on PWB- NO Check gears for overload and, if they are
A and GND change from DC5V to DC0V okay, change M15.
when the Start key is pressed?
3 Check M16 for operation. NO Change PWB-A.
Does the voltage across PJ2A-9B on PWB-
A and GND change from DC0V to DC24V
when the Start key is pressed?
4 Does the voltage across PJ2A-11B on YES Change PWB-A.
PWB-A and GND change from DC5V to NO Check gears for overload and, if they are
DC0V when the Start key is pressed? okay, change M16.

T-45
6) C0072 : Main Hopper Toner Replenishing Motor M9's Failure to Turn
Relevant Electrical Parts
Main Hopper Toner Replenishing Motor M9 Master Board PWB-A
Toner Bottle Home Position Sensor PC4 Toner Replenishing Motor Control Board PWB-O

1155C09TAB

◆C0072
Step Check Item Result Action
1 Manually turn the Toner Bottle a half turn NO Check for overloads and then check step
and then close the Upper Front Door. 4.
Does the Toner Bottle turn at this time?
2 Does the voltage across PJ2A-10A on NO Change PWB-A.
PWB-A and GND change from DC24V to
DC0V when step 1 is performed once
again?
3 Does the voltage across PJ30-3 and PJ30- NO Change PWB-O.
4 on PWB-O change from 0V to AC12V
when step 1 is performed once again?
4 Is PC41 fully operational? YES Change PWB-A or M9.
Does the voltage across PJ2A-5A on PWB- NO Change PC4.
A and GND change from DC5V to DC0V
when step 1 is performed once again?

T-46
7) C0090 : Developing Unit Drive Motor M1's Failure to Turn
Relevant Electrical Parts
Developing Unit Drive Motor M1 Master Board PWB-A
Power Supply Board PWB-C

1155C10TAA

◆C0090
Step Check Item Result Action
1 Check M1 for operation. NO Change PWB-A.
Does the voltage across PJ7A-5A on PWB-
A and GND change from DC5V to DC0V
when the Start key is pressed?
2 Does the voltage across PJ7A-7A on PWB- NO Check gears for overload and, if they are
A and GND change from DC5V to DC0V okay, change M1.
when the Start key is pressed?
3 Is the voltage across PJ7C-4B on PWB-C YES Change PWB-A or M1.
and GND DC24V? NO Change PWB-C.

T-47
8) C0100 : PC Drum Charge Comb Cleaning Motor M7's Failure to Turn
Defective Drum Comb Cleaning Home Position Sensor PC16
C0110 : Image Transfer/Paper Separator Wire Cleaning Motor M8's Failure to Turn
Defective Transfer/Separator Wire Cleaning Home Position Sensor PC17
Relevant Electrical Parts
PC Drum Charge Comb Cleaning Motor M7 Transfer/Separator Wire Cleaning Home Position
Drum Comb Cleaning Home Position Sensor Sensor PC17
PC16 Master Board PWB-A
Image Transfer/Paper Separator Wire Cleaning Wire Cleaning Motor Drive Board PWB-P
Motor M8

1155C12TAA

T-48
◆C0100
Step Check Item Result Action
1 Check the “I/O Check” screen to see if NO Check the PC16 actuator for operation
PC16 is operational. and, if it is okay, change PC16.
Manually turn the screw shaft to bring the
cleaner to its home position. Is the "Clean
(Charge)" input signal “1” when the PC Unit
is slid into the copier? Is the input signal
“0” when the PC Unit is slid into the copier
with the cleaner located at a position other
than home?
2 Does the cleaner holder move smoothly NO Check for burrs on the housing, a
when the screw shaft is turned manually? deformed screw, and M7 gear.
3 Check M7 for operation. YES Change PWB-P or M7.
Does the voltage across PJ10A-6A on NO Change PWB-A.
PWB-A and GND remain DC5V for approx.
1 sec. when the Power Switch is turned ON
and then change to DC0V?

◆C0110
Step Check Item Result Action
1 Check the “I/O Check” screen to see if NO Check the PC17 actuator for operation
PC17 is operational. and, if it is okay, change PC17.
Manually turn the screw shaft to bring the
cleaner to its home position. Is the "Clean
(Trance.)" input signal “1” when the Trans-
port Tray is slid into the copier and the M4
lock lever is raised? Is the input signal “0”
when the Transport Tray is slid into the
copier and the lock lever is raised with the
cleaner located at a position other than
home?
2 Does the cleaner holder move smoothly NO Check for burrs on the housing, a
when the screw shaft is turned manually? deformed screw, and M8 gear.
3 Check M8 for operation. YES Change PWB-P or M8.
Does the voltage across PJ3A-13A on NO Change PWB-A.
PWB-A and GND remain DC5V for approx.
1 sec. when the Power Switch is turned ON
and then change to DC0V?

T-49
9) C0200 : PC Drum Charge Corona Leak Detected
C0210 : Image Transfer Corona Leak Detected
C0220 : Developing Bias Leak Detected
C0230 : Paper Separator Corona Leak Detected
Relevant Electrical Parts
PC Drum Charge/Developing Bias HV HV1 Master Board PWB-A
Image Transfer/Paper Separator HV HV2 Power Supply Board PWB-C

1155C13TAA

T-50
◆C0200
Step Check Item Result Action
1 Is the Comb Electrode installed properly? NO Install the Comb Electrode properly.
2 Is the Comb Electrode dirty or has it YES Clean or change the Comb Electrode.
snapped?
3 Is “C0200” shown even when PJ38HV1 is YES Change PWB-A.
unplugged from HV1? NO Change HV1.

◆C0210, C0230
Step Check Item Result Action
1 Is the Image Transfer/Paper Separator NO Install the Image Transfer/Paper Separa-
Coronas Unit installed properly? tor Coronas Unit properly.
2 Are the Image Transfer/Paper Separator YES Clean or change the corona wires.
Coronas wires dirty or have they snapped?
3 Is “C0210” or “C0230” shown even when YES Change PWB-A.
PJ1HV2 is unplugged from HV2? NO Change HV2.

◆C0220
Step Check Item Result Action
1 Is the developing bias contact intact? NO Clean or change the developing bias con-
tact.
2 Is "C0220" shown even when PJ38HV1 is YES Change PWB-A.
unplugged from HV1? NO Change HV1.

T-51
10) C0400 : Exposure Lamp FL1's Failure to Turn ON
C0420 : Exposure Lamp FL1 Turning ON at Abnormal Timing
C14A0: Exposure Lamp Heater UN13 Failure (during Warming-up)
C14A1: Exposure Lamp Heater UN13 Failure (Abnormally Low Temperature)
C14A2: Exposure Lamp Heater UN13 Failure (Abnormally High Temperature)
C14A3: IR Warming-up Failure
Relevant Electrical Parts
Exposure Lamp FL1 Master Board PWB-A
Exposure Lamp Inverter Board UN10 Power Supply Board PWB-C
Exposure Lamp Holder UN11 Image Processing Board PWB-IB
Exposure Lamp Heater UN13 Lamp Flexible Printed Circuit PWB-IE

1155C14TAB

T-52
◆C0400, C0420
Step Check Item Result Action
1 Has Exposure Lamp FL1 blackened? YES Change FL1.
2 Does the Exposure Lamp turn ON when NO Check PWB-IE and check step 4 and
"Exp. Lamp Check" of "Function (I.R.)" onward.
under "I.R. & EDH Check" available from
the Tech. Rep. mode is run?
3 Does "NG" appear when "Address Adjust" YES Check the optical path to the CCD for
of "Function (I.R.)" under "I.R. & EDH possible obstruction.
Check" available from the Tech. Rep. mode
is run?
4 Does "NG" appear when "Scanning Check" YES Change PWB-IB or UN10.
of "Function (I.R.)" under "I.R. & EDH
Check" available from the Tech. Rep. mode
is run?
5 Is the voltage across PJ9C-7B on PWB-C YES Change PWB-A.
and GND DC24V? NO Change PWB-C.

◆C14A0, C14A1, C14A2, C14A3


Step Check Item Result Action
1 Is the resistance across PJ3UN10-1 and NO Change UN13 or PWB-IE.
PJ3UN10-2 on UN10 about 30 ohms?
2 Does the voltage across PJ7A-6A on PWB- NO Change PWB-A.
A and GND go LOW when the Power
Switch is turned ON?
3 Does the value for "IR Thermistor" shown NO Change PWB-A or UN10.
on the I/O Check screen change when the
Power Switch is turned ON?

T-53
11) C0500 : Warming-up Failure
C0510 : Abnormally Low Fusing Temperature
C0520 : Abnormally High Fusing Temperature
C0540 : Fusing Roller Thermistor Loading Failure
C0550 : Hard Protect Detected
<Metric Areas>
Relevant Electrical Parts
Upper Fusing Roller Heater Lamp H1 Upper Fusing Heater Lamp SSR1 SSR1
Lower Fusing Roller Heater Lamp H2 Lower Fusing Heater Lamp SSR2 SSR2
Upper Fusing Roller Thermistor TH1 Upper Fusing Heater Lamp SSR3 SSR3
Lower Fusing Roller Thermistor TH2 Lower Fusing Heater Lamp SSR4 SSR4
Upper Fusing Roller Thermal Fuse TF1 Main Relay (RY1)
Lower Fusing Roller Thermal Fuse TF2 Master Board PWB-A
Upper Guide Plate Resistor R1 Power Supply Board PWB-C
Lower Guide Plate Resistor R2

1155C26TAB

T-54
<Inch Areas>
Relevant Electrical Parts
Upper Fusing Roller Heater Lamp H1 Lower Fusing Roller Thermal Fuse TF2
Lower Fusing Roller Heater Lamp H2 Upper Fusing Heater Lamp SSR1 SSR1
Upper Fusing Roller Thermistor TH1 Lower Fusing Heater Lamp SSR2 SSR2
Lower Fusing Roller Thermistor TH2 Main Relay (RY1)
Upper Fusing Roller Thermal Fuse TF1 Master Board PWB-A
Power Supply Board PWB-C

1155C27TAB

T-55
◆C0500, C0510
Step Check Item Result Action
1 Remove the Fusing Unit Front Cover and NO Check step 7 and onward.
then turn ON the Power Switch. Does H1
turn ON at this time?
2 Does H2 turn ON when the malfunction is NO Check step 8 and onward.
reset with the surface temperature of the
Lower Fusing Roller at 135°C as indicated
on "Level History" available from the Tech.
Rep. mode?
3 Is TH1 or TH2 installed properly? NO Correct the installation of TH1 or TH2.
4 Is TH1 or TH2 dirty? YES Clean or change TH1 or TH2.
5 Measure the resistance of TH1 (across YES Change TH1.
CN28-2 and 3 on the Fusing Unit end). Is
the measurement infinity?
6 Measure the resistance of TH2 (across YES Change TH2.
CN32-2 and 3 on the Fusing Unit end). Is
the measurement infinity?
7 Does the voltage across PJ8A-3B on PWB- NO Change PWB-A.
A and GND change from DC5V to DC0V
when the Power Switch is turned ON?
8 Does the voltage across PJ8A-4B on PWB- NO Change PWB-A.
A and GND change from DC5V to DC0V
when step 2 is performed again?
9 Unplug CN4 (8P). Is there continuity NO Check H1 or TF1 for continuity.
across CN4-1 and 4 on the Fusing Unit
end?
10 Unplug CN4 (8P). Is there continuity NO Check H2 or TF2 for continuity.
across CN4-5 and 8 on the Fusing Unit
end?
11 Is the voltage across PJ4C-3A on PWB-C YES Change PWB-A, SSR1 or SSR2.
and GND, and across PJ4C-2A on PWB-C NO Cange PWB-C.
and GND, DC5V?

T-56
◆C0520
Step Check Item Result Action
1 Does H1 remain ON after the copier has NO Check step 4 and onward.
completed warming up? Or, is H2 ON when
"Fuser (Lower)" shown on "Level History"
available from "Tech. Rep. Mode" is 140°C
or more?
2 Does the voltage across PJ8A-3B on PWB- NO Change PWB-A.
A and GND change from DC0V to DC5V
after the copier has completed warming
up?
3 Is the voltage across PJ8A-4B on PWB-A YES Change SSR1 or SSR2.
and GND DC5V when "Fuser (Lower)" NO Change PWB-A.
shown on "Level History" available from
"Tech. Rep. Mode" is 140°C or more?
4 Unplug CN69 (8P). Is the circuit across YES Change TH1.
CN69-1 and 2 on the Fusing Unit end
closed?
5 Unplug CN69 (8P). Is the circuit across YES Change TH2.
CN69-5 and 6 on the Fusing Unit end
closed?
6 Is the voltage across PJ4C-3A on PWB-C YES Change PWB-A.
and GND, and across PJ4C-2A on PWB-C NO Change PWB-C.
and GND, DC5V?

◆C0540
Step Check Item Result Action
1 Check the Thermistor Set signal. YES Change PWB-A.
Does the value ("0" or "1") for "Thermistor NO Check CN69 (8P), CN28 (4P), CN32
Set" shown on the I/O Check screen (4P), and CN11 (32P).
change properly when the Transport Tray is
slid in and out of the copier?

◆C0550
Step Check Item Result Action
1 Does "C0550" appear again even after a YES Change either PWB-A, Fusing Unit,
malfunction has been reset? SSR1, or SSR2.

T-57
12) C0600 : Scanner Motor M31 Malfunction
C0602 : Cable Unwound
C0650 : SHOME Signal Error
Relevant Electrical Parts
Scanner Motor M31 Digital Image Processing Board PWB-IB
Scanner Reference Position Sensor PC55 SCP Board PWB-IC

1155C16TAA

T-58
◆C0600
Step Check Item Result Action
1 Is PJ3IC securely plugged into PWB-IC? NO Plug it in securely.
2 Check M31 for operation. NO Check gears for overload and, if they are
Does the voltage across PJ1IC-11 on okay, change M31 or PWB-IC.
PWB-IC and GND change from DC5V to
DC0V when the malfunction is reset?
3 Is the voltage across PJ3IC-6 on PWB-IC YES Change PWB-IB.
and GND DC5V? NO Change PWB-IC.

◆C0602
Step Check Item Result Action
1 Has the cable snapped off, is it unwound or YES Correct or change the cable.
loose, or does a portion of the cable ride
over another?
2 Is PJ3IC plugged properly into PWB-IC? NO Plug it in properly.
3 Check M31 for operation. NO Check gears and belts for overload and, if
Does the voltage across PJ1IC-11 on they are okay, change M31 or PWB-IC.
PWB-IC and GND change from DC5V to
DC0V when the malfunction is reset?
4 Is the voltage across PJ3IC-6 on PWB-IC NO Change PWB-IC.
and GND DC5V?
5 Is PJ9IB plugged properly into PWB-IB and NO Plug them in properly.
PJ14 into PC55?
6 Does the voltage across PJ9IB-2A on YES Change PWB-IB.
PWB-IB and GND change to DC0V when NO Change PC55.
PC55 is blocked?

◆C0650
Step Check Item Result Action
1 Has the cable snapped off, is it unwound or YES Correct or change the cable.
loose, or does a portion of the cable ride
over another?
2 Is PJ9IB securely plugged into PWB-IB NO Plug them in securely.
and PJ14 into PC55?
3 Is the light blocking plate installed prop- NO Reinstall.
erly?
4 Does the voltage across PJ9IB-2A on YES Change PWB-IB.
PWB-IB and GND change to DC0V when NO Change PC55.
PC55 is unblocked?

T-59
13) C0910 : 2nd Drawer Lift-Up Failure
C0911 : 2nd Drawer Lock Release Failure (Inch Areas)
C0914 : 2nd Drawer Lift-Up Motor M25's Failure to Turn
<Metric Areas>
Relevant Electrical Parts
2nd Drawer Lift-Up Motor M25 Master Board PWB-A
2nd Drawer Paper Lift-Up Sensor PC41 Drawer S/P Board PWB-F
2nd Drawer Lift-Up Motor Pulse Sensor PC26

1155C28TAA

T-60
<Inch Areas>
Relevant Electrical Parts
2nd Drawer Lift-Up Motor M25 2nd Drawer Lower Position Sensor PC19
2nd Drawer Paper Lift-Up Sensor PC41 Master Board PWB-A
2nd Drawer Lift-Up Motor Pulse Sensor PC26 Drawer S/P Board PWB-F
2nd Drawer Paper Descent Key UN8 2nd Drawer Flexible Printed Circuit PWB-M2

1155C29TAA

T-61
<Metric Areas>
◆C0910, C0914
Step Check Item Result Action
1 Does M25 start turning when the 2nd NO Check for overloads and then check step
Drawer is slid out and back in? 3 and onward.
2 Does the voltage across PJ4F-3 on PWB-F YES Check gears for overload and, if they are
and GND change from DC0V to DC24V okay, change M25.
when step 1 is performed again? NO Change PWB-A or PWB-F.
3 Check PC26 for operation. NO Check the PC26 pulse disk and, if it is
Does the voltage across PJ4A-13 on PWB- okay, change PC26.
A and GND alternate between DC0V and
DC5V when step 1 is performed again?
4 Is PC41 fully operational? YES Change PWB-A or PWB-F.
Make the input port check using “I/O NO Check the PC41 actuator and, if it is okay,
Check.” change PC41.

<Inch Areas>
◆C0910, C0911, C0914
Step Check Item Result Action
1 Does M25 start turning when the 2nd NO Check for overloads and then check step
Drawer is slid into the copier and UN8 3 and onward.
turned ON?
2 Does the voltage across PJ6F-6 on PWB-F YES Check gears for overload and, if they are
and GND change from DC0V to DC24V okay, change PWB-M2 or M25.
when step 1 is performed again? NO Change PWB-A or PWB-F.
3 Is PC41 fully operational? NO Check the PC41 actuator and, if it is okay,
Make the input port check using “I/O change PC41.
Check.”
4 Check PC26 for operation. NO Check the PC26 pulse disk and, if it is
Does the voltage across PJ4A-13 on PWB- okay, change PC26.
A and GND alternate between DC0V and
DC5V when step 1 is performed again?
5 Is PC19 fully operational? YES Change PWB-A, PWB-F, or PWB-M2.
Make the input port check using “I/O NO Check the PC19 actuator and, if it is okay,
Check.” change PC19.

T-62