SONOLINE Prima
Digital Ultrasound System
US
SONOLINE Prima Digital Ultrasound System
2
SONOLINE Prima Digital Ultrasound System
3
SONOLINE Prima Digital Ultrasound System
4
SONOLINE Prima Digital Ultrasound System
Documentation Devices
ENHANCED OBSTETRICAL CALCULATIONS • B&W video printer (standard): SONY UP 890 MD
AND REPORT PACKAGE (Standard) • VCR option (external)
- SV0 9500 MD (NTSC/EIA)
Adds enhanced features to the basic obstetrical - SV0 9500 MDP (PAL/CCIR)
measurement package with: • Multi-format camera option (external)
- CCM601 (EIA)
• Additional Measurements and Calculations: humerus - CCM 601 (CCIR)
length: ulnar length: clavicle length: binocular distance:
tibia length: foot length: yolk sac diameter: nuchal
thickness: cervical length: cistema magna distance: SYSTEM SOFTWARE
lateral ventricular width: hemispheric width:
transcerebellar diameter: renal dimension: amniotic • User-selectable operation in English, German, French
fluid index: BPD by TCD: TCD / AC ratio: LVW / HW or Spanish
ratio: CorBPD (corrected BPD): two displays of EFW • Standard software includes complete operating
• Other features include: system with factory-defined system settings for all
- Twin gestational measurements and reports applications.
- Dedicated early gestational report
- Additional user-defined tables and formulas (one
table/formula per parameter)
- Four user-defined measurements
- Fetal growth graphs and growth trend analysis
5
SONOLINE Prima Digital Ultrasound System
Siemens reserves the right to modify the design and specifications contained herein without prior notice. Please contact your local Siemens
Medical Systems Sales Representative for the most current information.
US
Siemen s Medical System s, Inc. Fr om outside the U.S.A. Siem ens Aktien gesellsch aft A9 1004-M2430-G060-03-4A00
Ultraso und Gr oup call 1 -425 -55 7-8 704 Medi cal Eng ineerin g Grou p DA 0100
P.O. Box 70 02 Europ e: +49 9131 84 0 Henkestrasse 127
Issaquah, WA 98027 -70 02 U.S.A. E-mail: hotlin e@sqi.com D-91052 Erlangen, Ge rmany © 20 00, Sieme ns Medical Syste ms, In c.
Te lephon e: 1-8 00-477-6627 www.si emensultr asound .com Teleph one: (+9131) 84 0 Printe d in U.S.A.
SONOLINE Prima Curved Linear Mechanical Specialty
Transducer 3.5C40S 5.0C40S 7.5L75S 7.5L45S 3.5SI15 3.5/5.0SI 5.0/7.5Micro 6.5EV13S Endo-V Endo-PII
Technology Curved Curved Linear Linear Mechanical Mechanical Mechanical Curved Mechanical Mechanical
Frequency 2.6/3.5/5.0 MHz 5.0 MHz 5.0/7.5 MHz 5.0/7.5 MHz 3.5 MHz 3.5/5.0 MHz 5.0/6.0/7.5 MHz 5.0/6.5 MHz 5.0/6.0/7.5 MHz 5.0/6.0/7.5 MHz
Multiple Frequencies yes no yes no no yes yes yes yes yes
Aperture 77mm 64mm 77mm 45mm 15mm 3.5MHz-15 mm 8mm 35mm 8mm 8mm
5.0 MHZ-10 mm
Frame Rates 12-74 fps 15-93 fps 11-69 fps 11-69 fps 18-36 fps 6-24 fps 10-34 fps 11-69 fps 10-17 fps 10-17 fps
Max Sector Angle/Width 89° 60° 67mm 39mm 100° 100° 100° 133° 220° 355°
Imaging Depths 60-240 mm 40-160 mm 30-120 mm 30-120 mm 30-240 mm 30-240 mm 40-160 mm 30-130 mm 40-160 mm 40-160 m
Elements 128 128 128 128 3 crystals 3 crystals 2 crystals 128 2 crystals 2 crystal
Biopsy Guide yes no yes yes yes yes no yes yes yes
Water Path no yes yes yes yes yes no no no yes
Abdominal l l l l
Obstetrics l l l m
Endovaginal l l
Endorectal l
Breast l l
Thyroid l l
Testicular l l
Pediatrics m l
Orthopedic l m
Cardiac l
Intraoperative
Neonatal m l
Emergency Room l l m l l m l l
l Primary m Secondary
Dynamic Receive Focus Dual-echo Processing Wide Bandwidth Transducers Dynamic Aperture Control
Dynamic Receive Focus automatically Dual-echo Processing automatically Wide Bandwidth Transducers Dynamic Aperture Control automatically
provides a continuous receive focus doubles the number of available receive automatically improve resolution and functions on receive signals to remove
throughout the entire field of view. By focal zone positions at any display depth. penetration simultaneously. Highly- beam focusing artifacts. Multi-element
continuously optimizing receive delays, Dual-echo Processing improves the damped transducers seek to improve focusing forms a curved wave front to
aperture size and frequency content, system imaging by paralleling the image quality and system resolution. focus the ultrasound beam. The diameter
Dynamic Receive Focus creates a more sequential processes of 1) electronically Damping transducer vibration to improve of this wave front is the effective
perfect acoustic lens. The result is a setting the receive focal zone position, axial resolution changes the bandwidth, transducer aperture. SONOLINE
remarkable improvement in axial and and 2) actually receiving the echo signals. or the range of frequencies transmitted. ultrasound systems automatically match
lateral resolution. While one portion of the system The greater the damping, the wider the the precise number of working
electronics is preparing the receive focus range of frequencies. Wide Bandwidth transducer elements to the focal zone
for the next focal zone position, another Transducers typically transmit a range range to keep the beam intensity
part is receiving the echo signals from of higher and lower frequencies that constant. Dynamic Aperture Control
the previous receive focal zone position. spans at least 60% of the center produces a uniform beam regardless of
Dual-echo Processing effectively operating frequency (COF). As the body's the focal zone position, removing image
removes uneven focusing artifacts while tissues naturally absorb higher ultrasonic artifacts due to uneven focusing.
maintaining high image frame rates. frequencies faster than lower
frequencies, Wide Bandwidth
Transducers automatically provide the
optimum frequency needed to image in
both the near and far fields. Re vised 01/200 0