MASTERTOP® 1324

Formerly Conifloor U
Seamless, self smoothing, polyurethane based flooring system

DESCRIPTION Suitable for Expands the field of


application on application
MASTERTOP 1324 is a seamless, self-smoothing, asphalt and other
flooring system based on an advanced solvent free moving substrates
polyurethane system. It has a smooth and seamless
surface that is easy to maintain in spotless hygienic TYPICAL PERFORMANCE DATA
condition and exhibits excellent resistance to traffic and
a wide spectrum of chemicals. Due to the polyurethane 7 days cure @ 20oC
base, the system exhibits an enhanced abrasion and Compressive strength (DIN 1164) : 75 N/mm2
crack resistance.
Tensile strength (DIN 53504) : 28 N/mm2
MASTERTOP 1324 is in compliance with:
Type Cert. Institute Classification Remarks Bond strength (DIN ISO 4624) : < 2.5 N/mm2
no.
Norm Abrasion resistance (DIN 53754) : 46 mg
Fire rating P 701- DAR Class 1 Elongation (DIN 53504) : 10%
1a
Shore D Hardness : 65
OS 8 cert. P 701- DAR passed Burning
1a Service Temperature : -20°C to 60°C
FDH and P 896-C DAR passed Federal Application Temperature : Minimum 10°C
FCH Health
approval Centre : Maximum 35°C
(Germany) PROPERTIES
Vapour DAR µ+20 to
diffusion 25,000 a. Components
Supply Colour Density
Adhesion P 701- DAR No blisters Adhesion form kg/L
under 1a m0/g0 3.1
rising N/mm2 Mastertop Primer 9 liquid amber 1.10
damp Part A #
conditions Mastertop Primer 9 liquid amber 1.05
Part B #
RECOMMENDED FOR Mastertop Body liquid coloured 1.45*
MASTERTOP 1324 is recommended for floors where a Coat 31 Part A
high level of aesthetics is required. It is ideal for floors in: Mastertop Body liquid amber
• chemical and pharmaceutical industries Coat 31 Part B
• food and beverage industries Mastertop Top liquid amber 1.0
Coat 42P Part A +
• nuclear power stations
Part B clear ‡
• super flat floors (high rack systems)
Mastertop Top liquid coloured 1.3
• industrial kitchens and hospitals
Coat 42P Part A +
• laboratories and sterile rooms Part B pigmented ‡
FEATURES AND BENEFITS Mastertop Top liquid clear 1.0*
Coat 61 Part A +
Good chemical Withstands chemical and Part B
resistance mechanical attack. Lower Filler F1 solid white 2.6
maintenance costs. Filler F5 solid white 2.6
Easy to clean and Allows floor surface to be
sterilise maintained in a hygienic * Part A and Part B mixed
state. ‡ Please refer to Sealer
Exhibits an Prevents cracking, providing
elongation of 10% longer service life.

Head Office Factories Representative Offices


Plaza GRI 10th & 11th Floor Jl. Daan Mogot Km.14 Jl. Jababeka V Blok I-1 Grand Residence Office Park, Komp. Pertokoan Royal Sunggal
Jl. HR Rasuna Said Blok X-2 No.1 Cengkareng, Cikarang Industrial Estate 1st Floor Jl. Gagak Hitam No. A-12
Jakarta 12950 Jakarta 11750 Bekasi 17530 Jl. Darmo Harapan Complex 1 Ring Road – Sunggal
Tel.: (6221) 5262481, 5262505 Tel.: (6221) 6190007 Tel.: (6221) 8934339 Surabaya 60187 Medan, Sumatera Utara 20128
Fax: (6221) 5262493, 5262515 Fax: (6221) 6190741 Fax: (6221) 8934342 Tel.: (6231) 7326705 Tel.: (6261) 8447110
Fax: (6231) 7326730 Fax: (6261) 8444072
MASTERTOP® 1324
b. Mixed systems substrate must be at least 3°C above the current dew
Components Mix ratio point temperature. Correct substrate preparation is
by weight critical for optimum performance. Surfaces must be
structurally sound, clean, and free from loose particles,
Mastertop Primer 9 # A:B 100:27 oil, grease, and all other contaminants. Remove oil,
A:B:F1 grease and wax contaminants by scrubbing with
Mastertop Body Coat 31 5:1:3 industrial grade detergent or degreasing compounds
followed by mechanical cleaning. Cement laitance, loose
Mastertop Top Coat A:B 10:1 particles, mould release agents, curing membrane and
42P clear ‡ other contaminants must be removed from the surface
by shot blasting, Blastrac®, scarifying or gritblasting
Mastertop Top Coat A:B 10:1
followed by vacuum cleaning. After pretreatment of the
42P pigmented ‡ substrate, the bond strength of the substrate must be at
9:1 least 1.5 N/mm2 (check with an approved pull-off tester
Mastertop Top Coat 61 A:B
at load rate 100 N/s). Fill surface irregularities such as
matt ‡
blowholes, cracks, honeycombs, etc. with EMACO®
Mastertop Top Coat 61 A:B 9:1 repair mortar to achieve a smooth and level surface.
glossy ‡ Protect walls and columns against resin splashes using
masking tape and polythene sheeting.
‡ Please refer to Sealer
PRIMER
Pot-life (minutes)
Mixing
@ 10°C @ 20°C @ 30°C Use a low speed (300 rpm) electric drill fitted with a paint
Mastertop Primer 9 70 35 20 mixer or a wing type paddle.
Premix one unit of Mastertop Primer 9 Part A with one
Mastertop Body 60 30 20 unit of Mastertop Primer 9 Part B for at least 3 minutes
Coat 31 until the mix is uniform and free of streaks.
Mastertop Top 30 Placing
120 60 Immediately after mixing, pour the material onto the
Coat 42P
substrate and spread the mixed material using a
Mastertop Top 120 60 30 squeegee or paint roller. The primary purpose of this
Coat 61 primer coat is to seal the substrate completely and avoid
air-bubbles in the body coat. On very porous substrates,
a second primer/sealer coat may be required. If in doubt,
Curing time (days) apply a sample patch of body coat.
Broadcasting of sand
@ 10°C @ 20°C @ 30°C F5 filler is broadcast at the rate of 0.8 to 1.0 kg/m2 onto
the wet primer; do not sand in excess. Placing of the
Mastertop Primer 9 5 2 1
body coat onto unsanded surfaces outside the recoating
Mastertop Body 7 3 2 interval will lead to interlayer failures (de-bonding).
Coat 32
BODY COAT
Mastertop Top 5 2 1 Mixing
Coat 42P Use a low speed (300 rpm) electric drill fitted with a paint
Mastertop Top 5 2 1 mixer or a wing type paddle. Mix one unit of Mastertop
Coat 61 Body Coat 31 Part A with one unit Mastertop Body Coat
31 Part B and mix for at least 3 minutes or until the mix
is uniform in colour and free of streaks. Continue to mix
Maximum permissible relative humidity and add one bag of F1 filler until a homogenous and
uniform mix is obtained.
@ 10°C at >23°C
Placing
All components 75 % 90 %
Depending on the substrate condition, apply 3.0 to 4.0
kg/m2 of the mix. Pour out the whole mix at once into
APPLICATION pours approximately. 200 to 300 mm wide, running
parallel to the work direction. Distribute and level the
Surface Preparation material with a notched trowel of the following
The compressive strength of the substrate shall not be dimensions: width/height/separation: 3/5/10 mm). Leave
less than 30 N/mm2. The substrates in contact with the the placed material for 10 to 15 minutes and de-aerate
ground must have a vapour barrier installed in with a spike roller.
SEALER
compliance with DIN 18195 or equivalent, or be primed For a matt finish with maximum abrasion and UV
with Mastertop Primer 9. The moisture content of the resistance, seal with Mastertop Top Coat 42P.
substrate shall not be higher than 8% throughout (Test
using with CM equipment). The temperature of the
MASTERTOP® 1324
For an infinitely variable glossy to matt finish with PACKAGING
maximum abrasion and UV resistance, seal with
Mastertop Top Coat 61. Mastertop Body Coat 31 15.0 kg/set
Following the application of the MASTERTOP 1324, 30.0 kg/set
protect coated area for at least 24 hours after laying from Mastertop Primer 9
spillage, dust, insects, small animals, traffic, rain, Filler F1 15.0 kg/bag
moisture, etc.
Filler F5 25.0 kg/bag
CLEANING
Mastertop Top Coat 42P 10.0 kg/set
Clean tools and equipment first with paper towels or Mastertop Top Coat 61 10.0 kg/bag
rags, then wipe using a solvent such acetone or
methyliso-butyl ketone before the resin systems
hardens. SHELF LIFE

ESTIMATING DATA MASTERTOP 1324 can be kept for 12 months from date
of manufacture if stored in original unopened packaging,
For thickness of 2.5 to 3.0 mm in a dry enclosed place at temperatures between 15 to
System Product kg/m2 Thickness 35°C, without exposing to direct sunlight.
mm
PRECAUTIONS
Primer Mastertop 0.4 - 0.6 0.3 - 0.4
Primer 9 MASTERTOP 1324 contains certain chemicals which
can cause skin irritation if exposed and respiratory
Broadcasting Filler F5 0.8 - 1.0 0.3 - 0.4
reaction if inhaled. Wear gloves, masks and use hand
sand barrier cream while handling the product. Wash
Body coat Mastertop 3.0 - 4.0 1.5 - 2.0 thoroughly after handling.
Body Coat 31 Should skin contact occur, wash immediately with soap
and water or an effective hand cleaner.
Abrasion Mastertop 0.1 - In case of accidental eye contact, wash with copious
resistant Top Coat 42 quantity of water and immediately seek medical advice.
sealer matt ‡ P If ingested, do not induce vomiting. Consult a doctor
Mastertop - immediately.
Abrasion 0.1
Top Coat 61 Vapours of solvents used for cleaning can be irritating. It
resistant
is therefore recommended that cleaning be done in
sealer matt /
wellventilated areas.
glossy ‡
For detailed Health, Safety and Environmental
‡ Please refer to Sealer Recommendations, please consult and follow all
instructions on the product Material Safety Data Sheet.
Fire: Keep away from sources of ignition. Do not smoke
whilst handling the product.
Flash point: 110°C.
MT 1324/02/0301

The technical information and application advice given in this BASF Construction Chemicals
publication are based on the present state of our best scientific and practical knowledge. As the
STATEMENT OF information herein is of a general nature, no assumption can be made as to a product's suitability for a
RESPONSIBILITY particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the
suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by
BASF Construction Chemicals either orally or in writing may be followed, modified or rejected by the
NOTE owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for
carrying out procedures appropriate to a specific application.