Sei sulla pagina 1di 56

Dry-installed Volute Casing Pump

Sewatec / Sewabloc
50 / 60 Hz
DIN / IEC motors

Type Series Booklet


Legal information/Copyright
Type Series Booklet Sewatec / Sewabloc

All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
edited or processed for any other purpose, nor otherwise transmitted, published or made available to
a third party without the manufacturer's express written consent.

Subject to technical modification without prior notice.

© KSB Aktiengesellschaft, Frankenthal 01.12.2014


Contents

Contents

Waste Water ...................................................................................................................................................... 5


Dry-installed Volute Casing Pump ................................................................................................................................. 5
Sewatec / Sewabloc ................................................................................................................................................... 5
Main applications ................................................................................................................................................ 5
Fluids handled ...................................................................................................................................................... 5
Operating data .................................................................................................................................................... 5
Designation .......................................................................................................................................................... 5
Design details ....................................................................................................................................................... 5
Materials .............................................................................................................................................................. 6
Product benefits .................................................................................................................................................. 6
Acceptance tests / Guarantees ............................................................................................................................ 6
Selection information .......................................................................................................................................... 7
Selection aid for materials and hydraulic systems per fluid ........................................................................ 7
Shaft seal ........................................................................................................................................................ 8
Impellers per material variant, 50 Hz ........................................................................................................... 9
Impellers per material variant, 60 Hz ......................................................................................................... 12
Diameters of F and E impellers per bearing bracket and speed ............................................................... 14
Diameters of K and D impellers per bearing bracket and speed .............................................................. 16
Overview of product features ........................................................................................................................... 18
Material variants ................................................................................................................................................ 19
Technical data .................................................................................................................................................... 20
K impeller ..................................................................................................................................................... 20
D impeller ..................................................................................................................................................... 22
F impeller ...................................................................................................................................................... 23
E impeller ..................................................................................................................................................... 24
Speeds for Sewatec 3H ................................................................................................................................ 25
Motor ratings ............................................................................................................................................... 25
Power reserves ............................................................................................................................................. 26
Selection charts ................................................................................................................................................. 27
Sewatec/Sewabloc, n = 2900-480 rpm, K impeller (speed-based selection chart) .................................... 27
Sewatec/Sewabloc, n = 1450/960/725/580 rpm, K impeller, nominal discharge nozzle diameter DN 250,
350, 400 (diameter-based selection chart) ................................................................................................. 28
Sewatec/Sewabloc, n = 960/725/580/480 rpm, K impeller, nominal discharge nozzle diameter 500, 600,
700 (diameter-based selection chart) ......................................................................................................... 29
Sewatec/Sewabloc, n = 2900-725 rpm, D impeller (speed-based selection chart) ................................... 30
Sewatec/Sewabloc, n = 2900-725 rpm, F impeller (speed-based selection chart) .................................... 31
Sewatec/Sewabloc, n = 1450-480 rpm, E impeller (speed-based selection chart) .................................... 32
Sewatec/Sewabloc, n = 1750/1160/875 rpm, impeller K, discharge nozzle diameter DN 50, 65, 80, 100,
125 (diameter selection chart) .................................................................................................................... 33
Sewatec/Sewabloc, n = 1750/1160/875 rpm, impeller K, discharge nozzle diameter DN 150, 200
(diameter selection chart) ........................................................................................................................... 34
Sewatec/Sewabloc, n = 1160/875/700 rpm, impeller K, discharge nozzle diameter DN 250, 300
(diameter selection chart) ........................................................................................................................... 35
Sewatec/Sewabloc, n = 875/700/585/500 rpm, impeller K, discharge nozzle diameter DN 350, 400, 500,
600, 700 (diameter selection chart) ............................................................................................................ 36
Sewatec/Sewabloc, n = 1750/1160/875 rpm, impeller D (diameter selection chart) ................................ 37

3
Contents

Sewatec/Sewabloc, n = 1750/1160/875 rpm, impeller F (diameter selection chart) ................................. 38


Sewatec/Sewabloc, n = 1160/875/700/585 rpm, impeller E (diameter selection chart) ............................ 39
Types of installation .......................................................................................................................................... 40
Installation types per bearing bracket and impeller type ......................................................................... 42
Recommended spare parts stock for 2 years' operation to DIN 24296 .......................................................... 45
Scope of supply .................................................................................................................................................. 45
General assembly drawings with list of components ...................................................................................... 46
General assembly drawing: Sewatec with bearing brackets S01, S02, S03, S04 ....................................... 46
General assembly drawing: Sewatec with bearing brackets S05, S06, S07, S08 ....................................... 48
General assembly drawing: Sewabloc ........................................................................................................ 54

4
Waste Water
Dry-installed Volute Casing Pump

Waste Water Designation


Example: Sewatec F80-315G 3ENH 200L 6
Key to the designation
Dry-installed Volute Casing Pump
Code Description
Sewatec Type series
Sewatec
Sewatec / Sewabloc Sewabloc
F Impeller type (⇨ Page 5)
K Closed multi-channel impeller
D Open, diagonal single-vane impeller
F Free-flow impeller
E Closed single-channel impeller
80 Nominal discharge nozzle diameter [mm]
315 Nominal impeller diameter [mm]
G Material variant (⇨ Page 19)
G Standard variant, wetted
components made of grey cast iron
G1 Like G, with impeller made of duplex
stainless steel
G2 Like G, with impeller made of white
cast iron
GH Like G, with impeller and
intermediate casing made of white
cast iron
GC Like G, with impeller and discharge
cover made of duplex stainless steel
3ENH Installation type (⇨ Page 40)
Sewabloc BLOC
BLOC-V
Main applications BLOC-VF
Sewatec Fig.0
▪ Waste water transport 3EN
▪ Waste water disposal 3ENH
3HZ
▪ Waste water management 3HM
▪ Transport of contaminated surface water 3HVGN
3HVGNH
▪ Sludge processing
V
VU
VGW
Fluids handled 200L Motor size
▪ Grey water 6 Number of motor poles
2, 4, 6, 8, 10, 12
▪ Solids-laden river water
▪ Contaminated surface water
▪ Waste water with faeces Design details
▪ Industrial waste water Design
▪ Gas-containing fluids Sewatec:
▪ Activated sludge ▪ Volute casing pump
▪ Digested sludge ▪ Back pull-out design
▪ Raw sludge ▪ Single-stage
▪ Various, application-oriented installation types
Sewabloc:
Operating data
▪ Volute casing pump
Operating properties
▪ Close-coupled pump with shaft seal
Characteristic Impeller type
▪ Various, application-oriented installation types
K D F E
Flow rate Q [m /h] ≤ 10000 ≤ 1260
3
≤ 680 ≤ 2520 Shaft seal
Q [l/s] ≤ 2775 ≤ 350 ≤ 189 ≤ 700 Sewatec (bearing brackets S01, S02, S03, S04), Sewabloc:
Head H [m] ≤ 115 ≤ 40 ≤ 40 ≤ 50 ▪ Two bi-directional mechanical seals in tandem
Fluid temperature T [°C] ≤ 70 ≤ 70 ≤ 70 ≤ 70 arrangement, with liquid reservoir
Operating pressure p [bar] ≤ 10 ≤ 10 ≤ 10 ≤ 10
Sewatec (bearing brackets S05, S06, S07, S08):
▪ Two bi-directional mechanical seals in tandem
arrangement, with liquid reservoir
▪ Gland packing

Sewatec / Sewabloc 5
Waste Water
Dry-installed Volute Casing Pump

Impeller type ▪ Grease-packed, zero-maintenance deep groove ball


bearings (sealed for life) on pump and drive end
K impeller:
Sewatec (bearing brackets S05, S06, S07, S08):
Closed multi- Suitable for the following ▪ Grease-packed rolling element bearings with re-
channel impeller fluids: lubrication system on pump and drive end
(impeller type K) contaminated, solids-laden,
non-gaseous fluids not Sewabloc:
containing stringy material ▪ Grease-packed, zero-maintenance deep groove ball
bearing (sealed for life) on pump end
K impellers are suitable for handling the following fluids:
▪ Activated sludge
▪ Landfill waste water
Materials
▪ Industrial waste water Overview of available materials

▪ Industrial effluent Description Material


Pump casing Grey cast iron (EN-GJL-250)
▪ Mechanically treated waste water
Wear plate Grey cast iron (EN-GJL-250) / duplex
▪ Pre-screened waste water stainless steel / wear-resistant white
▪ Contaminated surface water cast iron
Impeller Grey cast iron (EN-GJL-250) / duplex
D impeller:
stainless steel / wear-resistant white
Open, diagonal Suitable for the following cast iron
single-vane fluids: Shaft Stainless steel (1.4021)
impeller fluids containing solid Casing wear ring Grey cast iron (EN-GJL-250)/VG 434
(impeller type D) substances and long fibres Mechanical seal SiC/SiC

E impeller:
Product benefits
Closed single- Suitable for the following ▪ Variable hydraulic systems
channel impeller fluids: The right impeller with optimum efficiency for every fluid.
(impeller type E) fluids containing solid High operating reliability due to wide free passages.
substances and long fibres
▪ Double mechanical seal in tandem arrangement with
external liquid feed makes for high operating reliability.
F impeller: ▪ Low maintenance thanks to grease-packed rolling element
bearings sealed for life
Free-flow Suitable for the following
▪ Standardised components are interchangeable within the
impeller fluids:
Sewatec/Sewabloc and Amarex KRT series, so spare parts
(impeller type F) fluids containing solids and
inventories can be optimised and costs reduced.
stringy material as well as
fluids with entrapped air or
gas
Acceptance tests / Guarantees
D, E and F impellers are suitable for handling the following ▪ Each pump is subjected to a performance test to KSB
fluids: Standard ZN 56535.
▪ Activated sludge ▪ Operating data is guaranteed to DIN EN ISO 9906 / 2 / 2B.
▪ Digested sludge
Acceptance tests
▪ Heating sludge
▪ Acceptance tests to ISO/DIN or comparable standards are
▪ Mixed water
available against a surcharge.
▪ Raw waste water
▪ Raw sludge Quality assurance
▪ Recirculated sludge ▪ Quality is assured by means of an audited and certified
Bearings quality assurance system to DIN EN ISO 9001.
Sewatec (bearing brackets S01, S02, S03, S04):

6 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Selection information detailed advice is available from our specialist department in


Halle. Make use of our laboratory's expertise when selecting
materials.
Selection aid for materials and hydraulic systems per
fluid
The table below for your guidance is based on KSB's long-
standing experience. The data are standard values and are not
to be considered as generally binding recommendations. More

Selection aid for materials and hydraulic systems per fluid


Fluid handled1) Recommended Recommended Comments, further recommendations
material impeller type2)
Grey water Grey cast iron K, D, E, F -
Solids-laden river water Grey cast iron K, D, E, F Free passage > any solids contained, possibly pre-
screened
Contaminated surface water Grey cast iron K, D, E, F Free passage > any solids contained, possibly pre-
screened
Waste water
- Untreated municipal waste water Grey cast iron F, D, E, (K)3) ATV recommends a free passage of 100 mm; min. free
passage of 75 mm; multi-channel impellers can be used
depending on the system conditions and free passage.
- Waste water containing air or gas Grey cast iron F Up to 8 %, contact KSB for fluids with high outgassing
rates
Sludge
- Raw sludge Grey cast iron F, E, D, K Pumpable up to a dry substance content of: 13 % (D),
8 % (F), 6 % (E), 5 % (K)
- Digested sludge Grey cast iron F, E, D Pumpable up to a dry substance content of: 13 % (D),
8 % (F), 6 % (E)
- Activated sludge Grey cast iron K Pumpable up to a dry substance content of: 5 % (K)
Industrial waste water containing ...
- Paint suspensions Grey cast iron K Solvent-free, observe the operator's instructions.
- Lacquer/paint/varnish suspensions Grey cast iron F, E Solvent-free, contact KSB for silicone-free version
- Fibres/pulp Grey cast iron F, D -
- Chips/swarf Grey cast iron K, F Material variants G2 or GH, special mechanical seal
- Abrasive substances4) Grey cast iron K, F Material variants G2 or GH, special mechanical seal
Mildly acidic industrial waste water Grey cast iron K, F Ph value ≥ 6.5 material variant G1 and FPM (Viton) O-
rings
Non-corrosive waste water
- Ammonia water Grey cast iron K -
- Ammonium hydroxide 5 % NH4OH Grey cast iron K -
- Urea 25 % (NH2)2-CO Grey cast iron K -
- Potassium hydroxide 10 % KOH Grey cast iron K -
- Calcium hydroxide 5 % Ca(OH)2 Grey cast iron K -
- Sodium hydroxide 5 % NaOH Grey cast iron K -
- Sodium carbonate 30 % Na2CO3 Grey cast iron K -
Non-corrosive waste water containing ...
- Aliphatic hydrocarbons, e.g. oils, Grey cast iron K -
petrol, butane, methane
- Aromatic hydrocarbons, e.g. Grey cast iron K FPM (Viton) O-rings5)
benzene, styrene
- Chlorinated hydrocarbons, e.g. Grey cast iron K FPM (Viton) O-rings5)
tetrachloroethylene, ethylene
chloride, chloroform, methylene
chloride
Highly abrasive industrial waste water causing wear (chemically neutral)6)

1) For any fluids which are not listed in this table contact KSB.
2) The first impeller type listed should be given preference.
3) Contact KSB.
4) Severe hydroabrasive wear occurs if solids contents of approx. 0.5 g/l or higher are combined with circumferential speeds
exceeding 20 m/s or low-flow conditions to the left of the duty point.
5) The hydrocarbons mentioned may occur in very high concentrations due to the difference in specific weight and their low
solubility. If this is the case, contact KSB.
6) The required material variants highly depend on the operating hours, rotational speed and flow velocity.

Sewatec / Sewabloc 7
Waste Water
Dry-installed Volute Casing Pump

Fluid handled1) Recommended Recommended Comments, further recommendations


material impeller type2)
- Water containing iron ore sinter Wear-resistant K Sinter content < 4 g/l, material variant GH, special
white cast iron mechanical seal
- Lime milk containing quartz and Wear-resistant K Lime milk of up to 15 %, material variant GH, special
pigment suspensions white cast iron mechanical seal
- Wash water containing solids Wear-resistant K, F Material selection based on fluid analysis, material
white cast iron variant GH, special mechanical seal
- Waste water containing dust or ash Wear-resistant K Material selection based on fluid analysis, material
white cast iron variant GH, special mechanical seal
Water/sand mixture Wear-resistant K, F Solids content of up to 5 g/l, material variant GH,
white cast iron special mechanical seal
Waste water and landfill seepage Duplex stainless K, F Material variant GC (not for seawater and brackish
water steel water)

Shaft seal
Available shaft seal types per bearing bracket
Bearing Standard design Standard variant7)
bracket
Mechanical seal with Stationary mechanical seal Inboard mechanical seal Gland packing
Sewabloc
Sewatec

elastomer bellows (NBR, with spring outside of fluid with covered spring9)
optional: Viton)8) (Cartex S10 cartridge seal)

S01 – ✘ - ✘ -
– B01 ✘ - - -
S02 – ✘ - ✘ -
– B02 ✘ - - -
S03 – ✘ - ✘ -
– B03 ✘ - - -
S04 – ✘ - ✘ -
S05 – ✘ - ✘ ✘
S06 – ✘ - - ✘
S07 – ✘ - - ✘
S08 – - ✘ - ✘

1) For any fluids which are not listed in this table contact KSB.
2) The first impeller type listed should be given preference.
7) A surcharge and longer delivery times apply to standard variants.
8) For all types of waste water
9) For very abrasive fluids or fluids containing metallic particles (e.g. shavings from drilling)

8 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Impellers per material variant, 50 Hz


Impeller types per material variant, 50 Hz
Size Bearing bracket Material variant
G10) G111) G212) GH13) GC14)
Sewatec Sewabloc Impeller Impeller Impeller Impeller Impeller
K D F E K D F E K D F E K D F E K D F E
050-250 S01 - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
050-250 - B01 ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
050-251 S02 - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
050-251 - B02 ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
065-250 S01 - ✘ - ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ -
065-250 - B01 ✘ - ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ -
080-250 S01 - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
080-250 - B01 ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
080-315 S03 - ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
080-315 S05 - - ✘ - - - ✘ - - - - - - - - - - - - - -
080-315 - B03 ✘ ✘ ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
080-316 S03 - - ✘ - - - ✘ - - - - - - - - - - - - - -
080-316 - B03 - ✘ - - - ✘ - - - - - - - - - - - - - -
100-250 S01 - ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
100-250 - B01 ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
100-251 S02 - ✘ ✘ ✘ ✘ ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
100-251 - B02 ✘ ✘ ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
100-252 S01 - - - ✘ - - - - - - - - - - - - - - - - -
100-252 - B01 - - ✘ - - - - - - - - - - - - - - - - -
100-253 S02 - - - ✘ - - - - - - - - - - - - - - - - -
100-253 - B02 - - ✘ - - - - - - - - - - - - - - - - -
100-315 S05 - - ✘ - - - ✘ - - - - - - - - - - - - - -
100-316 S03 - - ✘ - - - ✘ - - - - - - - - - - - - - -
100-316 - B03 - ✘ - - - ✘ - - - - - - - - - - - - - -
100-400 S04 - ✘ - - - ✘ - - - - - - - - - - - - - - -
100-400 S05 - ✘ - - - ✘ - - - - - - - - - - - - - - -
100-401 S04 - ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - - - - - - - - -
100-401 S05 - ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - - - - - - - - -
125-315 S03 - ✘ - ✘ - - - - - - - - - - - - - - - - -
125-315 - B03 ✘ - ✘ - - - - - - - - - - - - - - - - -
125-317 S03 - - - - ✘ - - - - - - - - - - - - - - - -
125-317 - B03 - - - - - - - - - - - - - - - - - - - -
150-251 S02 - - ✘ - - - ✘ - - - - - - - - - - - - - -
150-251 - B02 - ✘ - - - ✘ - - - - - - - - - - - - - -
150-315 S03 - ✘ ✘ ✘ ✘ ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
150-315 - B03 ✘ ✘ ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
150-400 S05 - - ✘ - - - ✘ - - - - - - - - - - - - - -
150-400 S04/S05 - ✘ - - - - - - - - - - - - - - - - - - -
150-401 S04 - ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - - - - - - - - -
150-401 S05 - ✘ ✘ ✘ ✘ ✘ ✘ ✘ - ✘ - ✘ - - - - - - - - -
150-401 S06 - - ✘ - ✘ - ✘ - - - - - - - - - - - - - -
151-401 S05 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
150-500 S05 - ✘ - - - ✘ - - - - - - - - - - - - - - -
150-500 S06 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-315 S03 - ✘ ✘ - - ✘ ✘ - - ✘ - - - ✘ - - - ✘ - - -
200-315 - B03 ✘ ✘ - - ✘ ✘ - - ✘ - - - ✘ - - - ✘ - - -
200-316 S03 - ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ - - -
200-316 - B03 ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ - - -
200-330 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
200-330 S05 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
200-400 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -

10) G = standard design; wetted components made of grey cast iron

Sewatec / Sewabloc 9
Waste Water
Dry-installed Volute Casing Pump

Size Bearing bracket Material variant


G10) G111) G212) GH13) GC14)
Sewatec Sewabloc Impeller Impeller Impeller Impeller Impeller
K D F E K D F E K D F E K D F E K D F E
200-400 S05 - ✘ ✘ - ✘ ✘ ✘ - - ✘ - - - - - - - - - - -
200-400 S06 - - ✘ - ✘ - ✘ - - - - - - - - - - - - - -
200-402 S04 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-402 S05 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-500 S05 - - - - ✘ - - - - - - - - - - - - - - - -
200-500 S06 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-500 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-500Ex S05 - - - - ✘ - - - - - - - - - - - - - - - -
200-501 S06 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-631 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-631 S08 - ✘ - - - ✘ - - - - - - - - - - - - - - -
250-400 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
250-400 S05 - ✘ ✘ - - ✘ ✘ - - ✘ - - - - - - - - - - -
250-400 S06 - - ✘ - - - ✘ - - - - - - - - - - - - - -
250-401 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
250-401 S05 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
250-500 S06 - - - - ✘ - - - - - - - - - - - - - - - -
250-500 S07 - - - - ✘ - - - - - - - - - - - - - - - -
250-630 S07 - ✘ - - ✘ ✘ - - - - - - - - - - - - - - -
250-630 S08 - ✘ - - ✘ ✘ - - - - - - - - - - - - - - -
250-900 S09 - ✘ - - - ✘ - - - - - - - - - - - - - - -
300-400 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
300-400 S05 - ✘ ✘ - - ✘ ✘ - - ✘ - - - - - - - - - - -
300-400 S06 - - ✘ - - - ✘ - - - - - - - - - - - - - -
300-401 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
300-401 S05 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
300-500 S06 - ✘ - - - ✘ - - - - - - - - - - - - - - -
300-500 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
300-630 S07 - - - - ✘ - - - - - - - - - - - - - - - -
300-630 S08 - - - - ✘ - - - - - - - - - - - - - - - -
350-500 S06 - ✘ - - - ✘ - - - - - - - - - - - - - - -
350-500 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
350-501 S06 - ✘ - - - - - - - - - - - - - - - - - - -
350-501 S07 - ✘ - - - - - - - - - - - - - - - - - - -
350-630 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
350-630 S08 - ✘ - - - ✘ - - - - - - - - - - - - - - -
350-710 S07 - - - - ✘ - - - - - - - - - - - - - - - -
350-710 S08 - ✘ - - ✘ ✘ - - - - - - - - - - - - - - -
400-500 S06 - ✘ - - - ✘ - - - - - - - - - - - - - - -
400-500 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
400-630 S08 - ✘ - - - - - - - - - - - - - - - - - - -
400-710 S09 - ✘ - - - - - - - - - - - - - - - - - - -
400-820 S09 - ✘ - - - ✘ - - - - - - - - - - - - - - -
400-820 S10 - ✘ - - - ✘ - - - - - - - - - - - - - - -
500-630 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
500-630 S08 - ✘ - - - ✘ - - - - - - - - - - - - - - -
500-632 S08 - ✘ - - - - - - - - - - - - - - - - - - -
500-710 S09 - ✘ - - - ✘ - - - - - - - - - - - - - - -
500-900 S09 - ✘ - - - - - - - - - - - - - - - - - - -
500-900 S10 - ✘ - - - - - - - - - - - - - - - - - - -

10) G = standard design; wetted components made of grey cast iron


11) G1 = like G with impeller made of duplex stainless steel
12) G2 = like G with impeller made of white cast iron
13) G2 = like G with impeller and intermediate casing made of white cast iron
14) GC = like G with impeller and discharge cover made of duplex stainless steel and shaft made of 1.4462

10 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Size Bearing bracket Material variant


G10) G111) G212) GH13) GC14)
Sewatec Sewabloc Impeller Impeller Impeller Impeller Impeller
K D F E K D F E K D F E K D F E K D F E
600-520 S07 - ✘ - - - - - - - - - - - - - - - - - - -
600-710 S08 - ✘ - - - - - - - - - - - - - - - - - - -
600-900 S10 - ✘ - - - ✘ - - - - - - - - - - - - - - -
700-900 S08 - ✘ - - - ✘ - - - - - - - - - - - - - - -

10) G = standard design; wetted components made of grey cast iron


11) G1 = like G with impeller made of duplex stainless steel
12) G2 = like G with impeller made of white cast iron
13) G2 = like G with impeller and intermediate casing made of white cast iron
14) GC = like G with impeller and discharge cover made of duplex stainless steel and shaft made of 1.4462

Sewatec / Sewabloc 11
Waste Water
Dry-installed Volute Casing Pump

Impellers per material variant, 60 Hz


Impeller types per material variant, 60 Hz
Size Bearing bracket Material variant
G15) G116) G217) GH18) GC19)
Sewatec Sewabloc Impeller Impeller Impeller Impeller Impeller
K D F E K D F E K D F E K D F E K D F E
050-250 S01 - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
050-250 - B01 ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
050-251 S02 - ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ - - -
050-251 - B02 ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ - - -
065-250 S01 - ✘ - ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ -
065-250 - B01 ✘ - ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ -
080-250 S01 - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
080-250 - B01 ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
080-315 S03 - ✘ - ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
080-315 S05 - - ✘ - - - ✘ - - - - - - - - - - - - - -
080-315 - B03 ✘ ✘ ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
080-316 S03 - - ✘ - - - ✘ - - - - - - - - - - - - - -
080-316 - B03 - ✘ - - - ✘ - - - - - - - - - - - - - -
100-250 S01 - - - ✘ ✘ - - ✘ - - - ✘ - - - ✘ - - - ✘ -
100-250 - B01 - - ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ -
100-251 S02 - ✘ ✘ ✘ ✘ ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
100-251 - B02 ✘ ✘ ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
100-252 S01 - - - ✘ - - - - - - - - - - - - - - - - -
100-252 - B01 - - ✘ - - - - - - - - - - - - - - - - -
100-253 S02 - - - ✘ - - - - - - - - - - - - - - - - -
100-253 - B02 - - ✘ - - - - - - - - - - - - - - - - -
100-315 S05 - - ✘ - - - ✘ - - - - - - - - - - - - - -
100-316 S03 - - ✘ - - - ✘ - - - - - - - - - - - - - -
100-316 - B03 - ✘ - - - ✘ - - - - - - - - - - - - - -
100-400 S04 - ✘ - - - ✘ - - - - - - - - - - - - - - -
100-400 S05 - ✘ - - - ✘ - - - - - - - - - - - - - - -
100-401 S04 - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - - - - - - - - -
100-401 S05 - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - - - - - - - - -
125-315 S03 - ✘ - ✘ - - - - - - - - - - - - - - - - -
125-315 - B03 ✘ - ✘ - - - - - - - - - - - - - - - - -
125-317 S03 - - - - ✘ - - - - - - - - - - - - - - - -
125-317 - B03 - - - - - - - - - - - - - - - - - - - -
150-251 S02 - - ✘ - - - ✘ - - - - - - - - - - - - - -
150-251 - B02 - ✘ - - - ✘ - - - - - - - - - - - - - -
150-315 S03 - ✘ ✘ ✘ ✘ ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
150-315 - B03 ✘ ✘ ✘ - ✘ ✘ ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ -
150-400 S05 - - ✘ - - - ✘ - - - - - - - - - - - - - -
150-400 S04/S05 - ✘ - - - - - - - - - - - - - - - - - - -
150-401 S04 - ✘ - ✘ - ✘ - ✘ - ✘ - ✘ - - - - - - - - -
150-401 S05 - ✘ - ✘ - ✘ ✘ ✘ - ✘ - ✘ - - - - - - - - -
150-401 S06 - - ✘ - - - ✘ - - - - - - - - - - - - - -
151-401 S05 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
150-500 S05 - ✘ - - - ✘ - - - - - - - - - - - - - - -
150-500 S06 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-315 S03 - ✘ ✘ - - ✘ ✘ - - ✘ - - - ✘ - - - ✘ - - -
200-315 - B03 ✘ ✘ - - ✘ ✘ - - ✘ - - - ✘ - - - ✘ - - -
200-316 S03 - ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ - - -
200-316 - B03 ✘ - - - ✘ - - - ✘ - - - ✘ - - - ✘ - - -
200-330 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
200-330 S05 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
200-400 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -

15) G = standard design; wetted components made of grey cast iron


16) G1 = like G with impeller made of duplex stainless steel
17) G2 = like G with impeller made of white cast iron
18) G2 = like G with impeller and intermediate casing made of white cast iron
19) GC = like G with impeller and discharge cover made of duplex stainless steel and shaft made of 1.4462

12 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Size Bearing bracket Material variant


G15) G116) G217) GH18) GC19)
Sewatec Sewabloc Impeller Impeller Impeller Impeller Impeller
K D F E K D F E K D F E K D F E K D F E
200-400 S05 - ✘ - - - ✘ ✘ - - ✘ - - - - - - - - - - -
200-400 S06 - - ✘ - - - ✘ - - - - - - - - - - - - - -
200-402 S04 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-402 S05 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-500 S05 - - - - - - - - - - - - - - - - - - - - -
200-500 S06 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-500 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
200-500Ex S05 - - - - - - - - - - - - - - - - - - - - -
200-501 S06 - - - - - - - - - - - - - - - - - - - - -
200-631 S07 - - - - - - - - - - - - - - - - - - - - -
200-631 S08 - - - - - - - - - - - - - - - - - - - - -
250-400 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
250-400 S05 - ✘ - - - ✘ ✘ - - ✘ - - - - - - - - - - -
250-400 S06 - - ✘ - - - ✘ - - - - - - - - - - - - - -
250-401 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
250-401 S05 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
250-500 S06 - - - - - - - - - - - - - - - - - - - - -
250-500 S07 - - - - - - - - - - - - - - - - - - - - -
250-630 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
250-630 S08 - ✘ - - - ✘ - - - - - - - - - - - - - - -
250-900 S09 - ✘ - - - ✘ - - - - - - - - - - - - - - -
300-400 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
300-400 S05 - ✘ - - - ✘ ✘ - - ✘ - - - - - - - - - - -
300-400 S06 - - ✘ - - - ✘ - - - - - - - - - - - - - -
300-401 S04 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
300-401 S05 - ✘ - - - ✘ - - - ✘ - - - - - - - - - - -
300-500 S06 - ✘ - - - ✘ - - - - - - - - - - - - - - -
300-500 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
300-630 S07 - - - - - - - - - - - - - - - - - - - - -
300-630 S08 - - - - - - - - - - - - - - - - - - - - -
350-500 S06 - ✘ - - - ✘ - - - - - - - - - - - - - - -
350-500 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
350-501 S06 - - - - - - - - - - - - - - - - - - - - -
350-501 S07 - ✘ - - - - - - - - - - - - - - - - - - -
350-630 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
350-630 S08 - ✘ - - - ✘ - - - - - - - - - - - - - - -
350-710 S07 - - - - - - - - - - - - - - - - - - - - -
350-710 S08 - - - - - - - - - - - - - - - - - - - - -
400-500 S06 - - - - - ✘ - - - - - - - - - - - - - - -
400-500 S07 - - - - - ✘ - - - - - - - - - - - - - - -
400-630 S08 - - - - - - - - - - - - - - - - - - - - -
400-710 S09 - ✘ - - - - - - - - - - - - - - - - - - -
400-820 S09 - ✘ - - - ✘ - - - - - - - - - - - - - - -
400-820 S10 - ✘ - - - ✘ - - - - - - - - - - - - - - -
500-630 S07 - ✘ - - - ✘ - - - - - - - - - - - - - - -
500-630 S08 - ✘ - - - ✘ - - - - - - - - - - - - - - -
500-632 S08 - ✘ - - - - - - - - - - - - - - - - - - -
500-710 S09 - ✘ - - - ✘ - - - - - - - - - - - - - - -
500-900 S09 - ✘ - - - - - - - - - - - - - - - - - - -
500-900 S10 - ✘ - - - - - - - - - - - - - - - - - - -
600-520 S07 - - - - - - - - - - - - - - - - - - - - -
600-710 S08 - - - - - - - - - - - - - - - - - - - - -
600-900 S10 - ✘ - - - ✘ - - - - - - - - - - - - - - -
700-900 S08 - - - - - ✘ - - - - - - - - - - - - - - -

15) G = standard design; wetted components made of grey cast iron


16) G1 = like G with impeller made of duplex stainless steel
17) G2 = like G with impeller made of white cast iron
18) G2 = like G with impeller and intermediate casing made of white cast iron
19) GC = like G with impeller and discharge cover made of duplex stainless steel and shaft made of 1.4462

Sewatec / Sewabloc 13
Waste Water
Dry-installed Volute Casing Pump

Diameters of F and E impellers per bearing bracket and speed

Density 1.0 kg/dm3


Selection table20) 21)
Size Bearing F impeller E impeller
bracket Speed [rpm] Speed [rpm]
50 Hz 60 Hz 50 Hz 60 Hz
Sewabloc
Sewatec

2900 1450 960 725 1750 1160 875 1450 960 725 580 480 1160 875 700 585

050-250 S01 - - 200 200 200 200 200 200 - - - - - - - - -


050-250 - B01 - 200 200 200 200 200 200 - - - - - - - - -
050-251 S02 - 190 - - - - - - - - - - - - - - -
050-251 - B02 190 - - - - - - - - - - - - - - -
065-250 S01 - - 210 210 210 - 210 210 - - - - - - - - -
065-250 - B01 - 210 210 210 - 210 210 - - - - - - - - -
080-250 S01 - - 210 - - - 210 - - - - - - - - - -
080-250 - B01 - 250 - - - 250 - - - - - - - - - -
080-315 S03 - 250 250 250 - 250 250 - - - - - - - - - -
080-315 S05 - - - - - - - - - - - - - - - - -
080-315 - B03 250 250 250 - 250 250 - - - - - - - - - -
080-316 S03 - - - - - - - - - - - - - - - - -
080-316 - B03 - - - - - - - - - - - - - - - -
100-250 S01 - - 210 210 - - 210 - 245 245 245 - - 245 245 245 -
100-250 - B01 - 265 265 - - 265 - - - - - - - - - -
100-251 S02 - - 265 - - 265 - - 265 265 265 - - 265 265 265 -
100-251 - B02 - 265 - - 265 - - - - - - - - - - -
100-252 S01 - - 250 250 - - 250 - - - - - - - - - -
100-252 - B01 - 250 250 - - 250 - - - - - - - - - -
100-253 S02 - - 265 - - 265 - - - - - - - - - - -
100-253 - B02 - 265 - - 265 - - - - - - - - - - -
100-315 S05 - - - - - - - - - - - - - - - - -
100-316 S03 - - - - - - - - - - - - - - - - -
100-316 - B03 - - - - - - - - - - - - - - - -
100-401 S04 - - 390 390 - - 390 390 412 412 412 - - 412 412 - -
100-401 S05 - - 390 390 - - 390 390 412 412 412 - - 412 412 - -
125-315 S03 - - 300 300 - 300 300 - - - - - - - - - -
125-315 - B03 - 300 300 - 300 300 - - - - - - - - - -
125-317 S03 - - - - - - - - - 330 330 - - 330 330 330 -
125-317 - B03 - - - - - - - - - - - - - - - -
150-251 S02 - - - - - - - - - - - - - - - - -
150-251 - B02 - - - - - - - - - - - - - - - -
150-315 S03 - - - 290 - - 290 290 320 320 320 - - 320 320 320 -
150-315 - B03 - - 290 - - 290 290 - - - - - - - - -
150-400 S05 - - - - - - - - - - - - - - - - -
150-401 S04 - - 390 390 390 - 390 390 - - - - - - - - -
150-401 S05 - - 390 390 390 - 390 390 384 407 407 - - - 407 - -
150-401 S06 - - - - - - - - 407 407 - - - 407 - - -
151-401 S05 - - - - - - - - - - - - - - - - -
150-500 S05 - - - - - - - - - - - - - - - - -
150-500 S06 - - - - - - - - - - - - - - - - -
200-315 S03 - - - - - - - - - - - - - - - - -
200-315 - B03 - - - - - - - - - - - - - - - -
200-316 S03 - - - - - - - - - - - - - - - - -
200-316 - B03 - - - - - - - - - - - - - - - -
200-330 S04 - - - - - - - - - - - - - - - - -
200-330 S05 - - - - - - - - - - - - - - - - -
200-400 S04 - - - - - - - - - - - - - - - - -
200-400 S05 - - - - - - - - 351 400 400 - - 351 400 - -
200-400 S06 - - - - - - - - 400 - - - - 400 - - -

20) Selection for a fluid density of 1.0 kg/dm³; higher densities on request only
21) For higher densities up to 1.2 kg/dm³ max.: refer to the corresponding table to select the impeller diameter per bearing
bracket and speed.

14 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Size Bearing F impeller E impeller


bracket Speed [rpm] Speed [rpm]
50 Hz 60 Hz 50 Hz 60 Hz

Sewabloc
Sewatec
2900 1450 960 725 1750 1160 875 1450 960 725 580 480 1160 875 700 585

200-500 S05 - - - - - - - - - 508 508 508 - - 508 - -


200-500 S06 - - - - - - - - - - - - - - - - -
200-500 S07 - - - - - - - - - - - - - - - - -
200-500Ex S05 - - - - - - - - - 500 500 500 - - - - -
200-501 S06 - - - - - - - - - - - - - - - - -
200-631 S07 - - - - - - - - - - - - - - - - -
200-631 S08 - - - - - - - - - - - - - - - - -
250-400 S04 - - - - - - - - - - - - - - - - -
250-400 S05 - - - - - - - - - - - - - - - - -
250-400 S06 - - - - - - - - - - - - - - - - -
250-401 S04 - - - - - - - - - - - - - - - - -
250-401 S05 - - - - - - - - - - - - - - - - -
250-500 S06 - - - - - - - - - - 475 516 516 - - 475 516
250-500 S07 - - - - - - - - - 516 516 516 516 - 516 516 516
250-630 S07 - - - - - - - - - 540 640 640 640 - - - -
250-630 S08 - - - - - - - - - 640 640 640 640 - 640 - -
300-400 S04 - - - - - - - - - - - - - - - - -
300-400 S05 - - - - - - - - - - - - - - - - -
300-400 S06 - - - - - - - - - - - - - - - - -
300-401 S04 - - - - - - - - - - - - - - - - -
300-401 S05 - - - - - - - - - - - - - - - - -
300-500 S06 - - - - - - - - - - - - - - - - -
300-500 S07 - - - - - - - - - - - - - - - - -
300-630 S07 - - - - - - - - - 530 640 640 640 - - - -
300-630 S08 - - - - - - - - - 640 640 640 640 - 640 640 640
350-500 S06 - - - - - - - - - - - - - - - - -
350-500 S07 - - - - - - - - - - - - - - - - -
350-501 S06 - - - - - - - - - - - - - - - - -
350-501 S07 - - - - - - - - - - - - - - - - -
350-630 S07 - - - - - - - - - - - - - - - - -
350-630 S08 - - - - - - - - - - - - - - - - -
350-710 S07 - - - - - - - - - - 740 740 740 - - - -
350-710 S08 - - - - - - - - - - 740 740 740 - - 740 740
400-500 S06 - - - - - - - - - - - - - - - - -
400-500 S07 - - - - - - - - - - - - - - - - -
400-630 S08 - - - - - - - - - - - - - - - - -
500-630 S07 - - - - - - - - - - - - - - - - -
500-630 S08 - - - - - - - - - - - - - - - - -
500-632 S08 - - - - - - - - - - - - - - - - -
600-520 S07 - - - - - - - - - - - - - - - - -
600-710 S08 - - - - - - - - - - - - - - - - -
700-900 S08 - - - - - - - - - - - - - - - - -

Sewatec / Sewabloc 15
Waste Water
Dry-installed Volute Casing Pump

Diameters of K and D impellers per bearing bracket and speed

Density 1.0 kg/dm3


Selection table22) 23)
Size Bearing K impeller D impeller
bracket Speed [rpm] Speed [rpm]
50 Hz 60 Hz 50 Hz 60 Hz
Sewabloc
Sewatec

2900 1450 960 725 580 480 1750 1160 875 700 585 2900 1450 960 725 1750 1160 875 700

050-250 S01 - - 260 260 260 - - - 260 260 - - - - - - - - - -


050-250 - B01 - 260 260 260 - - - 260 260 - - - - - - - - - -
050-251 S02 - 265 - - - - - 265 - - - - - - - - - - - -
050-251 - B02 265 - - - - - 265 - - - - - - - - - - - -
065-250 S01 - - 230 230 230 - - - 230 230 - - - - - - - - - -
065-250 - B01 - 230 230 230 - - - 230 230 - - - - - - - - - -
080-250 S01 - - 235 235 - - - - 235 - - - - - - - - - - -
080-250 - B01 - 235 235 - - - - 235 - - - - - - - - - - -
080-315 S03 - 220 - - - - - 220 - - - - - 260 260 - - 260 - -
080-315 S05 - - - - - - - - - - - - 260 - - - 260 - - -
080-315 - B03 220 - - - - - 220 - - - - - 260 260 - - 260 - -
080-316 S03 - - - - - - - - - - - - - 306 - - - 306 - -
080-316 - B03 - - - - - - - - - - - - 306 - - - 306 - -
100-250 S01 - - 256 256 256 - - - - - - - - - - - - - - -
100-250 - B01 - 256 256 256 - - - - - - - - - - - - - - -
100-251 S02 - - 256 - - - - 256 256 - - - - 265 - - - 265 - -
100-251 - B02 - 256 - - - - 256 256 - - - - 265 - - - 265 - -
100-315 S05 - - - - - - - - - - - - 222 - - - 222 - - -
100-316 S03 - - - - - - - - - - - - - 306 - - - 306 - -
100-316 - B03 - - - - - - - - - - - - 306 - - - 306 - -
100-400 S04 - - 408 408 - - - - 408 408 - - - - - - - - - -
100-400 S05 - - 408 408 - - - - 408 408 - - - - - - - - - -
100-401 S04 - - 404 404 404 - - - 404 404 - - - - - - - - - -
100-401 S05 - - 404 404 404 - - - 404 404 - - - - - - - - - -
125-315 S03 - - 312 312 312 - - 312 312 312 - - - - - - - - - -
125-315 - B03 - 312 312 312 - - 312 312 312 - - - - - - - - - -
125-317 S03 - - - - - - - - - - - - - - - - - - - -
125-317 - B03 - - - - - - - - - - - - - - - - - - -
150-251 S02 - - - - - - - - - - - - - 254 254 254 - 254 254 -
150-251 - B02 -- - - - - - - - - - - - 254 254 254 - 254 254 -
150-315 S03 - - 312 312 312 - - 312 312 312 - - - 317 317 317 - 317 317 -
150-315 - B03 - 312 312 312 - - 312 312 312 - - - 317 317 317 - 317 317 -
150-400 S04 - - 408 408 - - - - 408 408 - - - - - - - - - -
150-400 S05 - - 408 408 - - - - 408 408 - - - 363 363 - - 363 - -
150-401 S04 - - 404 404 404 - - - 404 404 - - - - - - - - - -
150-401 S05 - - 404 404 404 - - 404 404 404 - - - - 412 - - - - -
150-401 S06 - - - - - - - - - - - - - 412 - - - 412 - -
151-401 S05 - - 408 408 - - - 380 408 - - - - - - - - - - -
150-500 S05 - - 504 504 504 - - - 504 504 - - - - - - - - - -
150-500 S06 - - 504 504 504 - - - 504 504 - - - - - - - - - -
200-315 S03 - - - 295 295 - - - 295 295 - - - 315 315 315 - 315 315 -
200-315 - B03 - - 295 295 - - - 295 295 - - - 315 315 315 - 315 315 -
200-316 S03 - - - 305 305 - - - 305 305 - - - - - - - - - -
200-316 - B03 - - 305 305 - - - 305 305 - - - - - - - - - -
200-330 S04 - - 326 326 326 326 326 - 326 326 - - - - - - - - - -
200-330 S05 - - 326 326 326 326 326 - 326 326 - - - - - - - - - -
200-400 S04 - - 404 404 404 404 404 - 404 404 - - - - - - - - - -
200-400 S05 - - 404 404 404 404 404 - 404 404 - - - - 402 - - - - -
200-400 S06 - - - - - - - - - - - - - 402 - - - 402 - -
200-402 S04 - - 408 408 - - - - 408 408 - - - - - - - - - -

22) Selection for a fluid density of 1.0 kg/dm³; higher densities on request only
23) For higher densities up to 1.2 kg/dm³ max.: refer to the corresponding table to select the impeller diameter per bearing
bracket and speed.

16 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Size Bearing K impeller D impeller


bracket Speed [rpm] Speed [rpm]
50 Hz 60 Hz 50 Hz 60 Hz

Sewabloc
Sewatec
2900 1450 960 725 580 480 1750 1160 875 700 585 2900 1450 960 725 1750 1160 875 700

200-402 S05 - - 408 408 - - - - 408 408 - - - - - - - - - -


200-500 S05 - - - - - - - - - - - - - - - - - - - -
200-500 S06 - - - 500 504 - - - - 500 - - - - - - - - - -
200-500 S07 - - 504 504 504 - - - 504 504 - - - - - - - - - -
200-500Ex S05 - - - - - - - - - - - - - - - - - - - -
200-501 S06 - - - 502 - - - - 450 502 - - - - - - - - - -
200-631 S07 - - - 622 - - - - - 622 - - - - - - - - - -
200-631 S08 - - - 622 - - - - 622 622 - - - - - - - - - -
250-400 S04 - - 370 370 370 370 370 - 370 370 - - - - - - - - - -
250-400 S05 - - 370 370 370 370 370 - 370 370 - - - - 375 375 - - 375 -
250-400 S06 - - - - - - - - - - - - - 375 - - - 375 - -
250-401 S04 - - 404 404 404 404 404 - 404 404 - - - - - - - - - -
250-401 S05 - - 404 404 404 404 404 - 404 404 - - - - - - - - - -
250-500 S06 - - - - - - - - - - - - - - - - - - - -
250-500 S07 - - - - - - - - - - - - - - - - - - - -
250-630 S07 - - - 630 630 - - - - 630 - - - - - - - - - -
250-630 S08 - - - 630 630 - - - 630 630 - - - - - - - - - -
250-900 S09 - - - 846 - - - - - 846 - - - - - - - - - -
300-400 S04 - - - 388 388 388 388 - - 388 388 - - - - - - - - -
300-400 S05 - - - 388 388 388 388 - 388 388 388 - - - 408 408 - - 408 -
300-400 S06 - - - - - - - - - - - - - 408 - - - 408 - -
300-401 S04 - - - 408 408 408 408 - - 408 408 - - - - - - - - -
300-401 S05 - - - 408 408 408 408 - 408 408 408 - - - - - - - - -
300-500 S06 - - - 460 504 504 504 - - - 504 - - - - - - - - -
300-500 S07 - - - 504 504 504 504 - - 504 504 - - - - - - - - -
300-630 S07 - - - - - - - - - - - - - - - - - - - -
300-630 S08 - - - - - - - - - - - - - - - - - - - -
350-500 S06 - - - 430 508 508 508 - - - 508 - - - - - - - - -
350-500 S07 - - - 508 508 508 508 - - 508 508 - - - - - - - - -
350-501 S06 - - - 500 509 509 509 - - 500 509 - - - - - - - - -
350-501 S07 - - - 509 509 509 509 - - 509 509 - - - - - - - - -
350-630 S07 - - - 610 630 630 630 - - - 630 - - - - - - - - -
350-630 S08 - - - 630 630 630 630 - - 630 630 - - - - - - - - -
350-710 S07 - - - - - - - - - - - - - - - - - - - -
350-710 S08 - - - 730 - - - - - 730 - - - - - - - - - -
400-500 S06 - - - - 501 508 - - - 464 508 - - - - - - - - -
400-500 S07 - - - 508 508 508 - - - 508 508 - - - - - - - - -
400-630 S08 - - - 620 - - - - - 620 - - - - - - - - - -
400-710 S09 - - - 739 739 - - - - 739 - - - - - - - - - -
400-820 S09 - - - 908 - - - - - 908 - - - - - - - - - -
500-630 S07 - - - 565 565 565 565 - - - 565 - - - - - - - - -
500-630 S08 - - - 565 565 565 565 - - 565 565 565 - - - - - - - -
500-632 S08 - - - 639 639 639 639 - - 639 639 639 - - - - - - - -
500-710 S09 - - - 739 - - - - - 739 - - - - - - - - - -
500-900 S09 - - - - - 908 - - - - - - - - - - - - - -
500-900 S10 - - - - 908 - - - - - 908 908 - - - - - - - -
600-520 S07 - - - - 532 532 - - - - 532 - - - - - - - - -
600-710 S08 - - - - 715 715 - - - - 715 - - - - - - - - -
600-900 S10 - - - - 908 908 - - - - 908 908 - - - - - - - -
700-900 S08 - - - - - 805 - - - - - 805 - - - - - - - -

Sewatec / Sewabloc 17
Waste Water
Dry-installed Volute Casing Pump

Overview of product features


Overview of features and accessories per installation type
Features Sewatec Sewabloc
Fig.0 V 3E 3H 3H with V VF
counter
shaft
Motor
Without motor ● ● ● ● ● ● ● ●
Standard KSB motor – ⃝24) ● ● ● ● ● ●
Motor make to customer's choice – ⃝24) ⃝ ⃝ ⃝ ⃝ ⃝ ⃝
Accessories installation set
Baseplate – ●25) ●26) ●27) ●28) ●29) ●25) –
Supporting frame, drive lantern, soleplate for the motor30) – Δ – – – – – –
Coupling, coupling guard30) – ●31) ● – ● – – –
Suction-side intermediate flanged piece with inspection hole30) ● ●32) ● ● ● ● ●32) ●32)
Suction duckfoot bend – – – – – – – ●
Fasteners: anchor bolts (A 4) – ● ● ● ● ● ● ●
Shaft seal
Mechanical seal Standard KSB mechanical seal with elastomer ●
bellows (bearing brackets S01, S02, S03, S04,
S05, S06, S07, B01, B02, B03)
Standard KSB mechanical seal with covered ⃝
spring (bearing brackets S01, S02, S03, S04, S05)
Stationary mechanical seal with spring outside ●
of fluid (bearing bracket S08)
Gland packing (bearing brackets S05 and larger only) ⃝ –
Coating
KSB standard ●
Primed to standard ●
Customer specification Δ
Flange
To DIN ●
To ANSI Δ
Sealing elements, bolts and screws
NBR/A433) ●
Viton/A4 ⃝
Acceptance tests
KSB Standard ZN 56535 ●
Customer specification34) ⃝

Key to the symbols


Symbol Description
● Standard design
⃝ Standard variant35)
Δ Special design35)

24) Special version for universal joint shaft


25) For vertical installation soleplate or feet
26) With height adjustment of the motor
27) Including belt drive, belt guard and height adjustment of the motor, motors 225 S and larger
28) Including belt drive, belt guard, counter shaft, coupling and coupling guard
29) Foundation rails for Sewabloc
30) Optional
31) For underfloor installation
32) Suction elbow
33) Screw plugs made of steel
34) HI Level A: K impeller; HI Level B: K impellers only, not for white cast iron; ISO 9906/(Grade 2): not for F impellers, not for
white cast iron; BS 5 316/I A: not for F impellers, not for white cast iron; BS 5 316/I B: for K impellers only, not for white
cast iron
35) A surcharge and longer delivery times apply to standard variants and special designs.

18 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Material variants
Overview of available materials
Part No. Description Material variant
G G1 G2 GH GC
101 Pump casing EN-GJL-250
135 Wear plate36) EN-GJL-25037) -
163 Discharge cover EN-GJL-250 EN-GJN-HB555 1.4517
183 Support foot Steel38)
210 Shaft 1.4021 1.4462
230 Impeller EN-GJL-250 1.4517 EN-GJN-HB555 1.4517
330 Bearing bracket EN-GJL-250
433 Mechanical seal SiC/SiC (Q1Q1 PGG)
502.01 Casing wear ring EN-GJL-25039) EN-GJL-250 (F impeller only)
VG 434
503 Impeller ring VG 434
452.01 Gland follower40) EN-GJS-400-15
454.01 Stuffing box ring40) EN-GJL-250
456.01 Neck bush40) EN-GJL-250
458.01 Lantern ring40) PTFE
524.01 Shaft protecting 1.4021
sleeve40)
914 Impeller screw Stainless steel41) Stainless steel
902/920 Screws, bolts and
nuts
Screw plugs Steel
Sealing elements NBR

Comparison of materials This type of carbon steel is resistant to cavitation, has excellent
strength values and is used for high circumferential speeds. An
EN ASTM
excellent resistance to pitting corrosion makes ferritic-
EN-GJL-250 A 48 Class 35 B austenitic stainless carbon steel a popular choice for pumping
EN-GJS-400-15 A 536 Class 60–40–18 acidic waste water with a high chloride content as well as
EN-GJN-HB555 A 532 Class II Type B (15 % Cr-Mo) seawater and brackish water. Thanks to its good chemical
1.4517 A 890 CD4MCuN resistance, e.g. also against waste water containing
1.4021 A 276 Type 420 phosphorous and sulphuric acid, this material is used in a wide
1.4462 A 182 F51 range of applications in the chemical industry and and process
engineering. Pumps made of duplex stainless steel have a very
VG 434 -
long service life, even when handling brines, chemical waste
C 35 E A 29 Gr. 1035 water (pH value 1 - 12), grey water and landfill leachate.
Wear-resistant white cast iron (EN-GJN-HB555 (XCR14) or
Description of materials technically equivalent material)
Grey cast iron EN-GJL-250 (lamellar graphite cast iron): This is a wear-resistant white cast iron for highly abrasive fluids
Lamellar graphite cast iron to EN 1561 is the most widely used containing sand, ash or iron ore sinter. It has a Rockwell
cast material for handling municipal sewage, waste water and hardness of 61.5 to 68, which is higher than that of hardened
sludges as well as stormwater and surface water. It is suitable chrome steel. Owing to its hardness, the chromium-
for neutral fluids which are only slightly aggressive and cause molybdenum alloy cast iron features a notably higher wear
little wear. The pH value should be ≥ 6.5, the sand content resistance than EN-GJL-250 grey cast iron and other cast
≤ 0.5 g/l. materials.
Duplex stainless steel (1.4517 or technically equivalent
material)

36) For E200-500, E250-500, E250-630, E300-630, E350-710 only


37) For D impeller optional: EN-GJN-HB555
38) Bearing brackets S05 and larger: EN-GJL-250
39) For E100-250, E100-251, E100-401, E150-315, E150-401, E200-315, E200-400: EN-GJN-HB555
40) For pump sets with gland packing only
41) Bearing brackets S05 and larger: CK 35N

Sewatec / Sewabloc 19
Waste Water
Dry-installed Volute Casing Pump

Technical data

K impeller
Overview
Size Bearing Pump data K impeller
bracket Shaft seal Pressure limits Inspection
hole diameter

Maximum operating pressure

Mass moment of inertia J


Torsional spring constant

Max. impeller diameter


Maximum test pressure

Min. impeller diameter


Double-flanged taper
No. of impeller channels

Max. free passage


Discharge nozzle

based on water
Suction nozzle

Mechanical seal
Gland packing

Casing
Sewabloc
Sewatec

[mm] [mm] [Nm/rad] [bar] [bar] [mm] [mm] [mm] [mm] [mm] [kgm2]
050-250 S01 - 65 50 13.000 - ✘ 10 15 - 80 3 15 260 150 0,05
050-250 - B01 65 50 13.000 - ✘ 10 15 - 80 3 15 260 150 0,05
050-251 S02 - 65 50 50.000 - ✘ 10 15 - 80 3 15 256 150 0,05
050-251 - B02 65 50 50.000 - ✘ 10 15 - 80 3 15 256 150 0,05
065-250 S01 - 80 65 13.000 - ✘ 6 9 - 80 2 50 230 170 0,08
065-250 - B01 80 65 13.000 - ✘ 6 9 - 80 2 50 230 170 0,08
080-250 S01 - 100 80 13.000 - ✘ 6 9 - 120 2 71 235 205 0,08
080-250 - B01 100 80 13.000 - ✘ 6 9 - 120 2 71 235 205 0,08
080-315 S03 - 100 80 80.000 - ✘ 10 15 - 120 2 33 220 140 0,07
080-315 S05 - 100 80 220.000 - ✘ 10 15 - 120 2 33 220 140 0,07
080-315 - B03 100 80 80.000 - ✘ 10 15 - 120 2 33 220 140 0,07
100-250 S01 - 100 100 50.000 - ✘ 6 9 118 120 2 71 256 210 0,07
100-250 - B01 100 100 50.000 - ✘ 6 9 118 120 2 71 256 210 0,07
100-251 S02 - 100 100 50.000 - ✘ 6 9 118 120 2 71 256 235 0,07
100-251 - B02 100 100 50.000 - ✘ 6 9 118 120 2 71 256 235 0,07
100-400 S04 - 150 100 190.000 - ✘ 10 15 100 150 2 76 408 355 1,1
100-400 S05 - 150 100 220.000 ■ ✘ 10 15 100 150 2 76 408 355 1,1
100-401 S04 - 125 100 190.000 - ✘ 10 15 120 120 2 50 404 310 0,50
100-401 S05 - 125 100 220.000 ■ ✘ 10 15 120 120 2 50 404 310 0,50
125-315 S03 - 125 125 80.000 - ✘ 6 9 118 120 2 76 312 235 0,09
125-315 - B03 125 125 80.000 - ✘ 6 9 118 120 2 76 312 235 0,09
150-315 S03 - 150 150 80.000 - ✘ 6 9 118 150 2 76 310 235 0,18
150-315 - B03 150 150 80.000 - ✘ 6 9 118 150 2 76 310 235 0,18
150-400 S04 - 200 150 190.000 - ✘ 10 15 100 200 3 76 404 300 0,83
150-400 S05 - 200 150 220.000 ■ ✘ 10 15 100 200 3 76 404 300 0,83
150-401 S04 - 150 150 190.000 - ✘ 10 15 120 200 2 76 404 330 0,916
150-401 S05 - 150 150 220.000 ■ ✘ 10 15 120 200 2 76 404 330 0,916
150-401 S06 - 150 150 370.000 ■ ✘ 10 15 120 200 2 76 404 330 0,916
151-401 S05 - 150 150 220.000 ■ ✘ 10 15 120 200 3 80 408 380 0,52
150-500 S05 - 150 150 220.000 ■ ✘ 10 15 118 150 3 60 504 350 0,71
150-500 S06 - 150 150 370.000 ■ ✘ 10 15 118 150 3 60 504 350 0,71
200-315 S03 - 200 200 80.000 - ✘ 6 9 118 200 3 70 295 210 0,22
200-315 - B03 200 200 80.000 - ✘ 6 9 118 200 3 70 295 210 0,22
200-316 S03 - 200 200 80.000 - ✘ 6 9 118 200 2 100 305 230 0,22
200-316 - B03 200 200 80.000 - ✘ 6 9 118 200 2 100 305 230 0,22
200-330 S04 - 250 200 190.000 - ✘ 10 15 118 200 3 70 326 270 0,35
200-330 S05 - 250 200 220.000 ■ ✘ 10 15 118 200 3 70 326 270 0,35
200-400 S04 - 200 200 190.000 - ✘ 10 15 200 200 3 80 404 330 0,52
200-400 S05 - 200 200 220.000 ■ ✘ 10 15 200 200 3 80 404 330 0,52
200-400 S06 - 200 200 370.000 ■ ✘ 10 15 200 200 3 80 404 330 0,52
200-402 S04 - 200 200 190.000 ■ ✘ 10 15 140 200 3 80 408 300 0,52
200-402 S05 - 200 200 220.000 ■ ✘ 10 15 140 200 3 80 408 300 0,52
200-500 S05 - 200 200 220.000 ■ ✘ 10 15 118 200 3 75 504 400 0,83
200-500 S06 - 200 200 370.000 ■ ✘ 10 15 118 200 3 75 504 400 0,83
200-500 S07 - 200 200 1.020.000 ■ ✘ 10 15 118 200 3 75 504 400 0,83

20 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Size Bearing Pump data K impeller


bracket Shaft seal Pressure limits Inspection
hole diameter

Maximum operating pressure

Mass moment of inertia J


Torsional spring constant

Max. impeller diameter


Maximum test pressure

Min. impeller diameter


Double-flanged taper
No. of impeller channels

Max. free passage


Discharge nozzle

based on water
Suction nozzle

Mechanical seal
Gland packing

Casing
Sewabloc
Sewatec

[mm] [mm] [Nm/rad] [bar] [bar] [mm] [mm] [mm] [mm] [mm] [kgm2]
200-501 S06 - 250 200 370.000 ■ ✘ 10 15 200 200 2 100 502 400 1,68
200-631 S07 - 250 200 1.020.000 ■ ✘ 10 15 140 200 2 105 622 480 4,41
200-631 S08 - 250 200 1.400.000 ■ ✘ 10 15 140 200 2 105 622 480 4,41
250-400 S04 - 250 250 190.000 - ✘ 10 15 143 200 3 85 370 330 0,5
250-400 S05 - 250 250 220.000 ■ ✘ 10 15 143 200 3 85 370 330 0,5
250-400 S06 - 250 250 370.000 ■ ✘ 10 15 143 200 3 85 370 330 0,5
250-401 S04 - 250 250 190.000 - ✘ 10 15 143 200 2 105 404 310 0,56
250-401 S05 - 250 250 220.000 ■ ✘ 10 15 143 200 2 105 404 310 0,56
250-630 S07 - 250 250 1.020.000 ■ ✘ 10 15 143 143 4 90 630 500 2,76
250-630 S08 - 250 250 1.400.000 ■ ✘ 10 15 143 143 4 90 630 500 2,76
250-900 S09 - 350 250 2.500.000 ■ ✘ 13 19,5 100 - 3 110 840 717 19,03
300-400 S04 - 300 300 190.000 - ✘ 10 15 143 200 3 100 388 332 0,75
300-400 S05 - 300 300 220.000 ■ ✘ 10 15 143 200 3 100 388 332 0,75
300-400 S06 - 300 300 370.000 ■ ✘ 10 15 143 200 3 100 388 332 0,75
300-401 S04 - 300 300 190.000 - ✘ 10 15 143 200 2 135 408 367 0,75
300-401 S05 - 300 300 220.000 ■ ✘ 10 15 143 200 2 135 408 367 0,75
300-500 S06 - 300 300 370.000 ■ ✘ 6 9 143 200 3 100 504 430 1,48
300-500 S07 - 300 300 1.020.000 ■ ✘ 6 9 143 200 3 100 504 430 1,48
350-500 S06 - 350 350 370.000 ■ ✘ 6 9 143 200 3 110 508 393 3,12
350-500 S07 - 350 350 1.020.000 ■ ✘ 6 9 143 200 3 110 508 393 3,12
350-501 S06 - 350 350 370.000 ■ ✘ 6 9 143 200 2 170 509 490 3,00
350-501 S07 - 350 350 1.020.000 ■ ✘ 6 9 143 200 2 170 509 490 3,00
350-630 S07 - 350 350 1.020.000 ■ ✘ 10 15 143 200 3 135 630 500 5,22
350-630 S08 - 350 350 1.400.000 ■ ✘ 10 15 143 200 3 135 630 500 5,22
350-710 S07 - 350 350 1.020.000 ■ ✘ 10 15 143 200 3 110 730 580 10,6
350-710 S08 - 350 350 1.400.000 ■ ✘ 10 15 143 200 3 110 730 580 10,6
400-500 S06 - 400 400 370.000 ■ ✘ 6 9 200 200 3 130 508 355 3,37
400-500 S07 - 400 400 1.020.000 ■ ✘ 6 9 200 200 3 130 508 355 3,37
400-630 S08 - 500 400 1.400.000 ■ ✘ 6 9 200 200 3 132 620 400 8,21
400-710 S09 - 500 400 2.500.000 ■ ✘ 10 15 150 - 3 165 739 587 16,0
400-820 S09 - 500 400 2.500.000 ■ ✘ 13 19,5 143 - 3 130 830 659 17,79
500-630 S07 - 500 500 1.020.000 ■ ✘ 4 6 200 200 3 133 582 490 6,11
500-630 S08 - 500 500 1.400.000 ■ ✘ 4 6 200 200 3 133 582 490 6,11
500-900 S09 - 600 500 2.500.000 ■ ✘ 9 13,5 200 - 3 202 908 721 45,0
500-900 S10 - 600 500 5.000.000 ■ ✘ 9 13,5 200 - 3 202 908 721 45,0
500-632 S08 - 500 500 1.400.000 ■ ✘ 4 6 200 200 3 135 639 560 6,00
500-710 S09 - 500 500 2.500.000 ■ ✘ 8/6,9 6,9/9,0 200 - 3 150 700 586 16,0
600-520 S07 - 500 600 1.020.000 ■ ✘ 4 6 200 200 3 145 532 457 7,02
600-710 S08 - 600 600 1.400.000 ■ ✘ 4 6 200 200 3 165 736 664 16,96
600-900 S10 - 700 600 5.000.000 ■ ✘ 9 13,5 200 - 3 180 908 760 50,0
700-900 S08 - 700 700 1.400.000 ■ ✘ 3 4,5 200 200 3 190 850 638 40,0

Key to the symbols


Symbol Description
■ Optional
✘ Standard

Sewatec / Sewabloc 21
Waste Water
Dry-installed Volute Casing Pump

D impeller
Overview
Size Bearing Pump data D impeller
bracket Shaft seal Pressure limits Inspection
hole diameter

Maximum operating pressure

Mass moment of inertia J


Torsional spring constant

Max. impeller diameter


Maximum test pressure

Min. impeller diameter


Double-flanged taper
No. of impeller channels

Max. free passage


Discharge nozzle

based on water
Suction nozzle

Mechanical seal
Gland packing

Casing
Sewabloc
Sewatec

[mm] [mm] [Nm/rad] [bar] [bar] [mm] [mm] [mm] [mm] [mm] [kgm2]
080-315 S03 - 100 80 80.000 - ✘ 10 15 - 120 1 70 260 242 0,124
080-315 S05 - 100 80 220.000 - ✘ 10 15 - 120 1 70 260 242 0,124
080-315 - B03 100 80 80.000 - ✘ 10 15 - 120 1 70 260 242 0,124
080-316 S03 - 125 80 80.000 - ✘ 10 15 - 120 1 70 306 280 0,222
080-316 - B03 125 80 80.000 - ✘ 10 15 - 120 1 70 306 280 0,222
100-251 S02 - 150 100 50.000 - ✘ 6 9 118 120 1 76 265 234 0,115
100-251 - B02 150 100 50.000 - ✘ 6 9 118 120 1 76 265 234 0,115
100-315 S05 - 125 100 220.000 - ✘ 10 15 100 120 1 75 222 196 0,065
100-316 S03 - 150 100 80.000 - ✘ 10 15 100 150 1 85 306 270 0,223
100-316 - B03 150 100 80.000 - ✘ 10 15 100 150 1 85 306 270 0,223
150-251 S02 - 150 150 50.000 - ✘ 6 9 120 150 1 100 254 225 0,150
150-251 - B02 150 150 50.000 - ✘ 6 9 120 150 1 100 254 225 0,150
150-315 S03 - 150 150 80.000 - ✘ 6 9 118 150 1 100 317 280 0,289
150-315 - B03 150 150 80.000 - ✘ 6 9 118 150 1 100 317 280 0,289
150-400 S05 - 200 150 220.000 ■ ✘ 10 15 100 200 1 100 363 326 0,573
150-401 S05 - 250 150 220.000 ■ ✘ 10 15 120 200 1 110 412 370 0,999
150-401 S06 - 250 150 370.000 ■ ✘ 10 15 120 200 1 110 412 370 0,999
200-315 S03 - 200 200 80.000 - ✘ 6 9 118 200 1 100 315 280 0,261
200-315 - B03 200 200 80.000 - ✘ 6 9 118 200 1 100 315 280 0,261
200-400 S05 - 250 200 220.000 ■ ✘ 10 15 125 200 1 100 402 355 0,825
200-400 S06 - 250 200 370.000 ■ ✘ 10 15 125 200 1 100 402 355 0,825
250-400 S05 - 250 250 220.000 ■ ✘ 10 15 143 200 1 120 375 320 0,653
250-400 S06 - 250 250 370.000 ■ ✘ 10 15 143 200 1 120 375 320 0,653
300-400 S05 - 300 300 220.000 ■ ✘ 10 15 143 200 1 150 408 375 0,925
300-400 S06 - 300 300 370.000 ■ ✘ 10 15 143 200 1 150 408 375 0,925

Key to the symbols


Symbol Description
■ Optional
✘ Standard

22 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

F impeller
Overview
Size Bearing Pump data F impeller
bracket Shaft seal Pressure Inspection
limits hole
diameter

Maximum operating pressure

Mass moment of inertia J


Torsional spring constant

Max. impeller diameter


Maximum test pressure

Min. impeller diameter


Double-flanged taper

Max. free passage


Discharge nozzle

based on water
Suction nozzle

Mechanical seal
Gland packing

Casing
Sewabloc
Sewatec

[mm] [mm] [Nm/rad] [bar] [bar] [mm] [mm] [mm] [mm] [mm] [kgm2]
050-250 S01 - 65 50 13.000 - ✘ 10 15 - 80 25 200 150 0,027
050-250 - B01 65 50 13.000 - ✘ 10 15 - 80 25 200 150 0,027
050-251 S02 - 65 50 50.000 - ✘ 10 15 - 80 25 190 150 0,027
050-251 - B02 65 50 50.000 - ✘ 10 15 - 80 25 190 150 0,027
065-250 S01 - 80 65 13.000 - ✘ 6 9 - 80 65 210 170 0,027
065-250 - B01 80 65 13.000 - ✘ 6 9 - 80 65 210 170 0,027
080-250 S01 - 100 80 13.000 - ✘ 6 9 - 120 76 210/250 150 0,095
080-250 - B01 100 80 13.000 - ✘ 6 9 - 120 76 210/250 150 0,095
080-315 S03 - 100 80 80.000 - ✘ 10 15 - 120 76 250 150 0,119
080-315 S05 - 100 80 220.000 - ✘ 10 15 - 120 76 250 150 0,119
080-315 - B03 100 80 80.000 - ✘ 10 15 - 120 76 250 150 0,119
100-250 S01 - 100 100 50.000 - ✘ 6 9 118 120 100 210/265 170 0,119
100-250 - B01 100 100 50.000 - ✘ 6 9 118 120 100 210/265 170 0,119
100-251 S02 - 100 100 50.000 - ✘ 6 9 118 120 100 265 249 0,119
100-251 - B02 100 100 50.000 - ✘ 6 9 118 120 100 265 249 0,119
100-252 S01 - 100 100 50.000 - ✘ 6 9 118 120 100 210/265 170 0,119
100-252 - B01 100 100 50.000 - ✘ 6 9 118 120 100 210/265 170 0,119
100-253 S02 - 100 100 50.000 - ✘ 6 9 118 120 100 265 249 0,119
100-253 - B02 100 100 50.000 - ✘ 6 9 118 120 100 265 249 0,119
100-401 S04 - 125 100 190.000 - ✘ 10 15 120 120 100 390 325 0,475
100-401 S05 - 125 100 220.000 ■ ✘ 10 15 120 120 100 390 325 0,475
125-315 S03 - 125 125 80.000 - ✘ 6 9 118 120 120 300 240 0,214
125-315 - B03 125 125 80.000 - ✘ 6 9 118 120 120 300 240 0,214
150-315 S03 - 150 150 80.000 - ✘ 6 9 118 150 120 290 250 0,214
150-315 - B03 150 150 80.000 - ✘ 6 9 118 150 120 290 250 0,214
150-401 S04 - 150 150 190.000 - ✘ 10 15 120 200 135 390 325 0,475
150-401 S05 - 150 150 220.000 ■ ✘ 10 15 120 200 135 390 325 0,475
150-401 S06 - 150 150 370.000 ■ ✘ 10 15 120 200 135 390 325 0,475

Key to the symbols


Symbol Description
■ Optional
✘ Standard

Sewatec / Sewabloc 23
Waste Water
Dry-installed Volute Casing Pump

E impeller
Overview
Size Bearing Pump data E impeller
bracket Shaft seal Pressure limits Inspection
hole diameter

Maximum operating pressure

Mass moment of inertia J


Torsional spring constant

Max. impeller diameter


Maximum test pressure

Min. impeller diameter


Double-flanged taper

Max. free passage


Discharge nozzle

based on water
Suction nozzle

Mechanical seal
Gland packing

Casing
Sewabloc
Sewatec

[mm] [mm] [Nm/rad] [bar] [bar] [mm] [mm] [mm] [mm] [mm] [kgm2]
100-250 S01 - 100 100 50.000 - ✘ 6 9 118 120 100 245 - 0,16
100-250 - B01 100 100 50.000 - ✘ 6 9 118 120 100 245 - 0,16
100-251 S02 - 100 100 50.000 - ✘ 6 9 118 120 100 265 - 0,16
100-251 - B02 100 100 50.000 - ✘ 6 9 118 120 100 265 - 0,16
100-401 S04 - 125 100 190.000 - ✘ 10 15 120 120 80 412 389 0,65
100-401 S05 - 125 100 220.000 ■ ✘ 10 15 120 120 80 412 389 0,65
125-317 S03 - 125 125 80.000 - ✘ 6 9 118 120 100 330 - 0,25
125-317 - B03 125 125 80.000 - ✘ 6 9 118 120 100 330 - 0,25
150-315 S03 - 150 150 80.000 - ✘ 6 9 118 150 120 320 - 0,25
150-315 - B03 150 150 80.000 - ✘ 6 9 118 150 120 320 - 0,25
150-401 S05 - 150 150 220.000 ■ ✘ 10 15 120 200 135 407 348 0,68
150-401 S06 - 150 150 370.000 ■ ✘ 10 15 120 200 135 388 348 0,68
200-400 S04 - 200 200 190.000 - ✘ 10 15 200 200 125 400 319 0,86
200-400 S05 - 200 200 220.000 ■ ✘ 10 15 200 200 125 400 319 0,86
200-400 S06 - 200 200 370.000 ■ ✘ 10 15 145 200 125 400 319 0,86
200-500 S05 - 200 200 220.000 ■ ✘ 10 15 118 200 150 508 420 2,07
200-500Ex S05 - 200 200 220.000 ■ ✘ 10 15 200 200 200 500 500 3,47
250-500 S06 - 250 250 370.000 ■ ✘ 10 15 200 200 180 516 454 3,22
250-500 S07 - 250 250 1.020.000 ■ ✘ 10 15 200 200 180 516 454 3,22
250-630 S07 - 250 250 1.020.000 ■ ✘ 10 15 200 143 196 640 540 6,56
250-630 S08 - 250 250 1.400.000 ■ ✘ 10 15 200 143 196 640 540 6,56
300-630 S07 - 300 300 1.020.000 ■ ✘ 10 15 200 200 220 640 530 7,25
300-630 S08 - 300 300 1.400.000 ■ ✘ 10 15 200 200 220 640 530 7,25
350-710 S07 - 400 350 1.020.000 ■ ✘ 6 9 200 200 280 740 670 15,21
350-710 S08 - 400 350 1.400.000 ■ ✘ 6 9 200 200 280 740 670 15,21

Key to the symbols


Symbol Description
■ Optional
✘ Standard

24 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Speeds for Sewatec 3H


As standard, electric motors of B5/V1 type of construction are
used up to 200 L, and B3 type of construction for 225 S and
larger.

Pump speeds of Sewatec 3H [rpm]


Characteristic Value
Transmission ratio 1,0 1,06 1,12 1,2 1,25 1,34 1,4 1,5 1,6 1,7 1,8 1,9 2,0
[i]
nM [rpm] 960 - - - - - - 685 640 600 565 535 505 480
1450 1450 1540 1620 1740 1810 1940 2030 2180 2320 2470 2610 2760 2900
1450 1370 1295 1210 1160 1080 1035 965 905 850 805 765 725
2900 2900 2735 2590 2415 2320 2165 2070 1935 1815 1705 1610 1525 1450

Note: ▪ The maximum transmission ratio equals 2 : 1.


▪ Refer to the speed curves for the maximum permissible ▪ 4-pole motors should be preferred to 2-pole motors as
speed. they have lower running noises.
▪ E and F impellers cannot be turned down. F impellers are ▪ For cost reasons 4-pole motors are preferable to motors
available in several sizes for each nominal diameter. with more than 4 poles.
▪ K impeller can be turned down. However, for reasons of ▪ Flywheels can be fitted, if the specified centre distances
efficiency it is preferable to adjust the pump set to the and pulley diameters are observed.
duty point by means of the above transmission ratios.

Motor ratings
Motor ratings, 50 Hz
Motor size Motor rating to IEC IP 55 [kW]42)
50 Hz
2900 rpm 450 rpm 960 rpm 750 rpm
100 L 3 2,2 1,5 0,75
3 1,1
112 M 4 4 2,2 1,5
132 S 5,5 5,5 3 2,2
7,5
132 M - 7,5 4 3
5,5
160 M 11 11 7,5 4
15 5,5
160 L 18,5 15 11 7,5
180 M 22 18,5 - -
180 L - 22 15 11
200 L 30 30 18,5 15
37 22
225 S - 37 - 18,5
225 M 45 45 30 22
250 M 55 55 37 30
280 S 75 75 45 37
280 M 90 90 55 45
315 S 110 110 75 55
315 M 132 132 90 75
315 L 160 160 110 90
200 200 132 110
250 250 160 132
315 315 200
315 - - 250 160
200
355 355 355 315 250
400 400 355 315
500 500 400

42) The motor ratings per motor size may differ, depending on the make.

Sewatec / Sewabloc 25
Waste Water
Dry-installed Volute Casing Pump

Motor size Motor rating to IEC IP 55 [kW]42)


50 Hz
2900 rpm 450 rpm 960 rpm 750 rpm
400 560 560 450 355
630 630 500 400
710 710 560 425
450
450 - - 615 485
630 500
690 545
560
600
630

Motor ratings, 60 Hz
Motor size Motor rating42) to IEC IP 55 [kW]
1750 rpm 1160 rpm 875 rpm
100 L 2,55 1,75 1,3
3,45
112 M 4,55 2,55 1,75
132 S 6,3 3,45 2,55
132 M 8,6 4,6 3,45
6,3
160 M 12,6 8,6 4,6
6,3
160 L 17,3 12,6 8,6
180 M 18,5 - -
180 L 25,3 18 13,2
200 L 34,5 22 18
26,5
225 S 42,5 - 22
225 M 52 36 26,5
250 M 63 44,5 36
280 S 86 54 44,5
280 M 104 66 54
315 S 127 90 66
315 M 152 108 90
315 L 184 132 108
230 158 132
300 192 158
400 240
315 288 - -
362
355 408 - -
460
575
400 644 - -
725

Power reserves Pump input power Recommended power reserve


for the drive
Pump input power Recommended power reserve [kW] [%]
for the drive
Exceeding 22, up to 55 ≈ 15
[kW] [%] Exceeding 55 ≈ 10
Up to 7.5 ≈ 30 (min. 1 kW)
Exceeding 7.5, up to 22 ≈ 20

42) The motor ratings per motor size may differ, depending on the make.

26 Sewatec / Sewabloc
Selection charts

Sewatec/Sewabloc, n = 2900-480 rpm, K impeller (speed-based selection chart)

20 30 40 50 US.gpm 100 200 300 400 500 1000 2000 3000 4000 5000

20 30 40 50 IM.gpm 100 200 300 400 500 1000 2000 3000 4000 5000
100
300

50-251K 150-500K 200-500K 200

50

40 100-400K 200-631K
80-315K 100-401K
30 150-400K 100

200-400K
20 125-315K
100-251K
50
50-250K 80-250K 200-330K
40

10 150-315K
30
65-250K

200-315K 20
200-316K
5

Dry-installed Volute Casing Pump


4
Sewatec / Sewabloc

100-250K

3 10

ft
2

H
5
[m]

Waste Water
4

1
1 Q[l/s] 2 3 4 5 10 20 30 40 50 100 200 300 400 500

4 5 m³/h 10 20 30 40 50 100 200 300 400 500 1000


27
Sewatec/Sewabloc, n = 1450/960/725/580 rpm, K impeller, nominal discharge nozzle diameter DN 250, 350, 400 (diameter-based selection chart)
28
Sewatec / Sewabloc

1000 US.gpm 2000 3000 4000 5000 10000 20000 30000

1000 IM.gpm 2000 3000 4000 5000 10000 20000


120
100
250-900K /6p 300

400-820K /6p
200
350-710K /6p
50
250-630K /6p
40 400-710K /6p

30 350-630K /6p 100

250-400K /4p
250-401K /4p 400-630K /6p
20

50
300-500K /6p 350-500K /6p
40
400-500K /6p
10
30
250-400K /6p 300-400K /6p
250-401K /6p 300-401K /6p
350-500K /8p 20

4 400-500K /8p

Dry-installed Volute Casing Pump


3 350-500K /10p 10
300-400K /8p
300-401K /8p
400-500K /10p ft
2

H 300-400K /10p
[m] 300-401K /10p 5

Waste Water
40 50 Q[l/s] 100 200 300 400 500 1000 2000

200 300 400 500 m³/h 1000 2000 3000 4000 5000
Sewatec/Sewabloc, n = 960/725/580/480 rpm, K impeller, nominal discharge nozzle diameter 500, 600, 700 (diameter-based selection chart)

4000 5000 US.gpm 10000 20000 30000 40000

3000 4000 5000 IM.gpm 10000 20000 30000


80

200

50

40
500-710K /6p
500-900K /8p 100
30
500-632K /6p
600-900K /8p

20
600-900K /10p
500-900K /10p
50
500-630K /6p 600-710K /8p
40

10 700-900K /10p
30
600-710K /10p
500-630K /8p

600-520K /8p 20

5 500-630K /10p 700-900K /12p

3 10

Dry-installed Volute Casing Pump


Sewatec / Sewabloc

ft
2

H
5
[m]

Waste Water
200 300 400 500 Q[l/s] 1000 2000 3000

1000 m³/h 2000 3000 4000 5000 10000


29
Sewatec/Sewabloc, n = 2900-725 rpm, D impeller (speed-based selection chart)
30
Sewatec / Sewabloc

200 300 400 500 US.gpm 1000 2000 3000 4000 5000

200 300 400 500 IM.gpm 1000 2000 3000 4000 5000
100
300

200

50

40

30 80-315D 150-401D 100


100-315D
150-400D
20

50
80-316D
100-316D 150-315D 200-400D 40

10 250-400D
30

200-315D 300-400D 20
100-251D 150-251D
5

Dry-installed Volute Casing Pump


3 10

ft
2

H
5
[m]
4

Waste Water
9 10 Q[l/s] 20 30 40 50 100 200 300 400 500

40 50 m³/h 100 200 300 400 500 1000


Sewatec/Sewabloc, n = 2900-725 rpm, F impeller (speed-based selection chart)

20 30 40 50 US.gpm 100 200 300 400 500 1000 2000 3000

20 30 40 50 IM.gpm 100 200 300 400 500 1000 2000


100
300

200

50 100-401F 80-315F

40
50-251F

30 100

80-250F 100-251F 125-315F 150-401F


20

50

40
65-250F 100-250F 100-253F
10
30

20
100-252F 150-315F
5

Dry-installed Volute Casing Pump


3 10
Sewatec / Sewabloc

ft
2

H
5
[m]
4

Waste Water
1 Q[l/s] 2 3 4 5 10 20 30 40 50 100 200

4 5 m³/h 10 20 30 40 50 100 200 300 400 500


31
Sewatec/Sewabloc, n = 1450-480 rpm, E impeller (speed-based selection chart)
32
Sewatec / Sewabloc

100 US.gpm 200 300 400 500 1000 2000 3000 4000 5000 10000

100 IM.gpm 200 300 400 500 1000 2000 3000 4000 5000 10000
50

40
150-401E

30 100

100-401E 250-630E

20 125-317E 200-400E 300-630E

100-251E 200-500EX 350-710E


50
250-500E

40

10
100-250E 150-315E 200-500E 30

20

3 10

Dry-installed Volute Casing Pump


ft
2

H
5
[m]

Waste Water
6 10 Q[l/s] 20 30 40 50 100 200 300 400 500 800

30 40 50 m³/h 100 200 300 400 500 1000 2000


Sewatec/Sewabloc, n = 1750/1160/875 rpm, impeller K, discharge nozzle diameter DN 50, 65, 80, 100, 125 (diameter selection chart)

3 4 5 m³/h 10 20 30 40 50 100 200 300 400

1 l/s 2 3 4 5 10 20 30 40 50 100
400
100
300

200
50

40

100 100-400K /6p 125-315K /4p 30

100-401K /6p 20

50
50-251K /4p
40 80-315K /4p 100-251K /4p
10
30

20
50-250K /6p 65-250K /6p 5

10 3
H 50-250K /8p 65-250K /8p 100-251K /6p

Dry-installed Volute Casing Pump


[ft]
2
Sewatec / Sewabloc

5 m
4
1
3

Waste Water
10 Q[US.gpm] 20 30 40 50 100 200 300 400 500 1000 2000

10 IM.gpm 20 30 40 50 100 200 300 400 500 1000


33
Sewatec/Sewabloc, n = 1750/1160/875 rpm, impeller K, discharge nozzle diameter DN 150, 200 (diameter selection chart)
34
Sewatec / Sewabloc

50 m³/h 100 200 300 400 500 1000

20 30 40 50 l/s 100 200 300 400


400
100
300

200
150-401K /4p 200-631K /6p 50

40

100 30
200-631K /8p
150-315K/ 4p 150-400K /6p 20

200-501K /6p
50
150-401K /6p
40 200-400K /6p
200-402K /6p 10
30
150-315K /6p 200-330K /6p

20
200-315K /6p 5

4
150-315K /8p
10 3
H 200-316K /6p

Dry-installed Volute Casing Pump


[ft]
200-315K /8p 2

5 200-330K /8p
200-316K /8p m
4
1
3

Waste Water
200 300 400 500 Q[US.gpm] 1000 2000 3000 4000 5000 7000

200 300 400 500 IM.gpm 1000 2000 3000 4000 5000
Sewatec/Sewabloc, n = 1160/875/700 rpm, impeller K, discharge nozzle diameter DN 250, 300 (diameter selection chart)

200 300 400 500 m³/h 1000 2000

50 l/s 100 200 300 400 500


400

100
300
250-900K /8p

250-630K/ 6p
200

50

40

250-630K /8p
100 30

20

50

40
250-400K /6p
10
30 300-400K /6p
300-401K /6p
m
250-400K /8p 250-401K /6p
20

Dry-installed Volute Casing Pump


300-400K /8p
250-401K /8p 300-401K /8p
Sewatec / Sewabloc

10 3
H
[ft] 300-400K /10p
300-401K /10p 2

Waste Water
700 1000 Q[US.gpm] 2000 3000 4000 5000 9000

1000 IM.gpm 2000 3000 4000 5000


35
Sewatec/Sewabloc, n = 875/700/585/500 rpm, impeller K, discharge nozzle diameter DN 350, 400, 500, 600, 700 (diameter selection chart)
36
Sewatec / Sewabloc

300 400 500 m³/h 1000 2000 3000 4000 5000 10000

100 l/s 200 300 400 500 1000 2000 3000


400

100
300

200 400-820K /8p

50
350-710K /8p
500-900K /10p 40

100 350-630K /8p 400-710K /8p


30

400-630K /8p 500-710K /8p 600-900K /10p


20

350-500K /8p
50
600-710K /10p
40 350-501K /8p
600-710K /12p
10
30 350-500K /10p
700-900K /12p
350-501K /10p 400-500K /8p 500-630K /8p m
20
600-520K /10p
5
700-900K /14p
4

Dry-installed Volute Casing Pump


400-500K /10p 500-630K /10p
10 3
400-500K /12p 500-630K /12p
H
[ft]
2

Waste Water
1000 Q[US.gpm] 2000 3000 4000 5000 10000 20000 30000 40000 50000

1000 IM.gpm 2000 3000 4000 5000 10000 20000 30000 40000
Sewatec/Sewabloc, n = 1750/1160/875 rpm, impeller D (diameter selection chart)

30 40 50 m³/h 100 200 300 400 500 1000

10 l/s 20 30 40 50 100 200 300


160

40

100 30

150-401D /6p 20

80-315D /4p
50

40 150-400D /6p

10
30 100-316D /6p
200-400D /6p 300-400D /6p

20 100-315D /4p 150-315D /6p

250-400D /6p 4

10 100-251D /6p 200-315 /6p 3

H
[ft]
150-251D /6p 250-400D /8p 2

Dry-installed Volute Casing Pump


5
Sewatec / Sewabloc

200-315D /8p m

1
3

Waste Water
100 Q[US.gpm] 200 300 400 500 1000 2000 3000 4000 5000 6000

100 IM.gpm 200 300 400 500 1000 2000 3000 4000
37
Sewatec/Sewabloc, n = 1750/1160/875 rpm, impeller F (diameter selection chart)
38
Sewatec / Sewabloc

20 30 40 50 m³/h 100 200 300 400 500

4 5 l/s 10 20 30 40 50 100
160

40

125-315F /4p
100 30
100-251F /4p

80-315F /4p
20

50

40
50-250F /4p 100-253F /4p 150-401F /6p 10
30

20

50-250F /6p 150-315F /6p 5

100-252F /6p 100-250F /6p 4


65-250F /6p
10 3
150-401F /8p
H 50-250F /6p
[ft] 80-250F /6p 150-315F /8p
2
65-250F /8p

Dry-installed Volute Casing Pump


5
m

1
3

Waste Water
50 Q[US.gpm] 100 200 300 400 500 1000 2000 3000

50 IM.gpm 100 200 300 400 500 1000 2000


Sewatec/Sewabloc, n = 1160/875/700/585 rpm, impeller E (diameter selection chart)

30 40 50 m³/h 100 200 300 400 500 1000 2000 3000 4000

10 l/s 20 30 40 50 100 200 300 400 500 1000


160

40

100 30

300-630E /8p 20

250-500E /8p
50
350-710E /10p
40 125-317E /6p

300-630E /10p 10
30
250-500E /10p 350-710E /12p
125-317E /8p

20
100-251E /6p
100-250E /6p 150-315E /6p 5
125-317E /10p
4

10 100-251E /8p 150-315E /8p 3


100-250E /8p
H
[ft]
100-251E /10p 150-315E /10p 2
100-250E /10p

Dry-installed Volute Casing Pump


5
Sewatec / Sewabloc

1
3

Waste Water
100 Q[US.gpm] 200 300 400 500 1000 2000 3000 4000 5000 10000 20000

100 IM.gpm 200 300 400 500 1000 2000 3000 4000 5000 10000
39
Waste Water
Dry-installed Volute Casing Pump

Types of installation

Horizontal installation
Sewatec - Fig. 0 Sewabloc

Bare shaft pump Pump set with directly flanged motor (B5/V1 type of
construction)

Sewatec - 3H (3HZ) Sewatec - 3H (3HM)

Pump set with baseplate, belt drive and belt guard Pump set with baseplate, belt drive, belt guard and motor stand

Sewatec - 3H with counter shaft (3HVG) Sewatec - 3E (3EN/3ENH)

Pump set with baseplate, coupling (also with coupling spacer), Pump set with directly coupled drive, baseplate, coupling (also
coupling guard, counter shaft stand, counter shaft, motor stand, with coupling spacer), coupling guard and height adjustment of
belt drive and belt guard the motor

Vertical installation
Sewatec – vertical (V) Sewatec – vertical (VU)

Bare shaft pump, soleplate and suction elbow Pump set with soleplate, drive lantern, coupling, coupling guard
and suction elbow

40 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Sewatec – vertical (VGW) Sewabloc – vertical (V)

Pump set with soleplate for pump and motor, supporting frame, Pump set with directly flanged motor (B5/V1 type of
drive lantern, suction elbow and universal joint shaft construction), with soleplate and suction elbow, for underfloor
installation

Sewabloc – vertical (VF)

Pump set with directly flanged motor (B5/V1 type of


construction), with suction duckfoot bend

Sewatec / Sewabloc 41
Waste Water
Dry-installed Volute Casing Pump

Installation types per bearing bracket and impeller type


Installation types per bearing bracket and impeller type
Size Installation types
Sewabloc Sewabloc-vertical Sewatec Sewatec-vertical
Bearing bracket

Impeller type

BLOC BLOC-V BLOC-VF Fig.0 3EN 3ENH 3HZ 3HM 3HVG-N 3HVG-NH V VU VGW
050-250 B01 F ✘ ✘ ✘ - - - - - - - - - -
050-250 B01 K ✘ ✘ ✘ - - - - - - - - - -
050-250 S01 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
050-250 S01 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
050-251 B02 F ✘ ✘ ✘ - - - - - - - - - -
050-251 B02 K ✘ ✘ ✘ - - - - - - - - - -
050-251 S02 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
050-251 S02 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
065-250 B01 F ✘ ✘ ✘ - - - - - - - - - -
065-250 B01 K ✘ ✘ ✘ - - - - - - - - - -
065-250 S01 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
065-250 S01 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
080-250 B01 F ✘ ✘ ✘ - - - - - - - - - -
080-250 B01 K ✘ ✘ ✘ - - - - - - - - - -
080-250 S01 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
080-250 S01 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
080-315 B03 D ✘ ✘ ✘ - - - - - - - - - -
080-315 B03 F ✘ ✘ ✘ - - - - - - - - - -
080-315 B03 K ✘ ✘ ✘ - - - - - - - - - -
080-315 S03 D - - - ✘ ✘ ✘ ✘ - - - ✘ - -
080-315 S03 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
080-315 S03 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
080-315 S05 D - - - ✘ ✘ ✘ ✘ ✘ - - - - -
080-316 B03 D ✘ ✘ ✘ - - - - - - - - - -
080-316 S03 D - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-250 B01 E - - - - - - - - - - - - -
100-250 B01 F ✘ ✘ ✘ - - - - - - - - - -
100-250 B01 K ✘ ✘ ✘ - - - - - - - - - -
100-250 S01 E - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-250 S01 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-250 S01 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-251 B02 D ✘ ✘ ✘ - - - - - - - - - -
100-251 B02 E - - - - - - - - - - - - -
100-251 B02 F ✘ ✘ ✘ - - - - - - - - - -
100-251 B02 K ✘ ✘ ✘ - - - - - - - - - -
100-251 S02 D - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-251 S02 E - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-251 S02 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-251 S02 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-252 B01 F ✘ ✘ ✘ - - - - - - - - - -
100-252 S01 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-253 B02 F ✘ ✘ ✘ - - - - - - - - - -
100-253 S02 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-315 B03 D ✘ ✘ ✘ - - - - - - - - - -
100-315 S03 D - - - - - - - - - - ✘ - -
100-315 S05 D - - - ✘ ✘ ✘ ✘ - - - - - -
100-316 B03 D ✘ ✘ ✘ - - - - - - - - - -
100-316 S03 D - - - ✘ ✘ ✘ ✘ - - - ✘ - -
100-400 S04 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ - -
100-400 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
100-401 S04 E - - - ✘ ✘ ✘ ✘ - - - - - -
100-401 S04 F - - - ✘ ✘ ✘ ✘ - - - - - -
100-401 S04 K - - - ✘ ✘ ✘ ✘ - - - - - -
100-401 S05 E - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
100-401 S05 F - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
100-401 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
125-315 B03 F ✘ ✘ ✘ - - - - - - - - - -
125-315 B03 K ✘ ✘ ✘ - - - - - - - - - -
125-315 S03 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
125-315 S03 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
125-317 B03 E - - - - - - - - - - - - -
125-317 S03 E - - - ✘ ✘ ✘ ✘ - - - ✘ - -
150-251 B02 D ✘ ✘ ✘ - - - - - - - - - -
150-251 S02 D - - - ✘ ✘ ✘ ✘ - - - ✘ - -
150-315 B03 D ✘ ✘ ✘ - - - - - - - - - -
150-315 B03 E - - - - - - - - - - - - -
150-315 B03 F ✘ ✘ ✘ - - - - - - - - - -
150-315 B03 K ✘ ✘ ✘ - - - - - - - - - -
150-315 S03 D - - - ✘ ✘ ✘ ✘ - - - ✘ - -
150-315 S03 E - - - ✘ ✘ ✘ ✘ - - - ✘ - -
150-315 S03 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
150-315 S03 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
150-400 S04 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ - -

42 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Size Installation types


Sewabloc Sewabloc-vertical Sewatec Sewatec-vertical

Bearing bracket

Impeller type

BLOC BLOC-V BLOC-VF Fig.0 3EN 3ENH 3HZ 3HM 3HVG-N 3HVG-NH V VU VGW
150-400 S05 D - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
150-400 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
150-401 S04 E - - - ✘ ✘ ✘ ✘ - - - ✘ - -
150-401 S04 F - - - ✘ ✘ ✘ ✘ - - - ✘ - -
150-401 S04 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
150-401 S05 D - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
150-401 S05 E - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
150-401 S05 F - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
150-401 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
150-401 S06 D - - - ✘ ✘ ✘ - - - - ✘ ✘ ✘
150-401 S06 E - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
150-500 S05 K - - - ✘ ✘ ✘ ✘ ✘ ✘ ✘ ✘ ✘ ✘
150-500 S06 K - - - ✘ - - - - - - ✘ ✘ -
151-401 S05 K - - - ✘ - - - - - - ✘ ✘ -
200-315 B03 D ✘ ✘ ✘ - - - - - - - - - -
200-315 B03 K ✘ ✘ ✘ - - - - - - - - - -
200-315 S03 D - - - ✘ ✘ ✘ ✘ - - - ✘ - -
200-315 S03 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
200-316 B03 K ✘ ✘ ✘ - - - - - - - - - -
200-316 S03 K - - - ✘ ✘ ✘ ✘ - - - ✘ - -
200-330 S04 K - - - ✘ ✘ ✘ ✘ - - - - - -
200-330 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
200-400 S04 E - - - ✘ ✘ ✘ ✘ - - - - - -
200-400 S04 K - - - ✘ ✘ ✘ ✘ - - - - - -
200-400 S05 D - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
200-400 S05 E - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
200-400 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
200-400 S06 D - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
200-400 S06 E - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
200-402 S04 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ - -
200-402 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
200-500 S05 E - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
200-500 S06 K - - - ✘ ✘ ✘ - - - - ✘ ✘ ✘
200-500 S07 K - - - ✘ ✘ ✘ - ✘ ✘ ✘ ✘ ✘ ✘
200-501 S06 K - - - ✘ - - - - - - ✘ ✘ -
200-631 S07 K - - - ✘ - - - - - - ✘ ✘ -
200-631 S08 K - - - ✘ - - - - - - ✘ ✘ -
250-400 S04 K - - - ✘ ✘ ✘ ✘ - - - - - -
250-400 S05 D - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
250-400 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
250-400 S06 D - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
250-401 S04 K - - - ✘ ✘ ✘ ✘ - - - - - -
250-401 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
250-500 S06 E - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
250-500 S07 E - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
250-630 S07 E - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
250-630 S07 K - - - ✘ ✘ ✘ - ✘ ✘ ✘ ✘ ✘ ✘
250-630 S08 E - - - ✘ ✘ ✘ - - ✘ ✘ ✘ ✘ ✘
250-630 S08 K - - - ✘ - - - - - - ✘ ✘ ✘
250-900 S09 K - - - - - - - - - - ✘ - -
300-400 S04 K - - - ✘ ✘ ✘ ✘ - - - - - -
300-400 S05 D - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
300-400 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
300-400 S06 D - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
300-401 S04 K - - - ✘ ✘ ✘ ✘ - - - - - -
300-401 S05 K - - - ✘ ✘ ✘ ✘ ✘ - - ✘ ✘ ✘
300-500 S06 K - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
300-500 S07 K - - - ✘ ✘ ✘ - - ✘ ✘ ✘ ✘ ✘
300-630 S07 E - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
300-630 S08 E - - - ✘ ✘ ✘ - - ✘ ✘ ✘ ✘ ✘
350-500 S06 K - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
350-500 S07 K - - - ✘ ✘ ✘ - ✘ ✘ ✘ ✘ ✘ ✘
350-501 S06 K - - - ✘ ✘ ✘ - ✘ - - ✘ ✘ ✘
350-501 S07 K - - - ✘ ✘ ✘ - - ✘ ✘ ✘ ✘ ✘
350-630 S07 K - - - ✘ ✘ ✘ - ✘ ✘ ✘ ✘ ✘ ✘
350-630 S08 K - - - ✘ ✘ ✘ - - - - ✘ ✘ ✘
350-710 S07 E - - - ✘ - - - - - - ✘ ✘ ✘
350-710 S08 E - - - ✘ ✘ ✘ - - ✘ ✘ ✘ ✘ ✘
350-710 S08 K - - - ✘ - - - - - - ✘ ✘ -
400-500 S06 K - - - ✘ - - - - - - ✘ ✘ -
400-500 S07 K - - - ✘ - - - - - - ✘ ✘ -
400-630 S08 K - - - ✘ - - - - - - ✘ ✘ -
400-710 S09 K - - - - - - - - - - ✘ - -
400-820 S09 K - - - - - - - - - - ✘ - -
500-630 S07 K - - - ✘ ✘ ✘ - ✘ ✘ ✘ ✘ ✘ ✘
500-630 S08 K - - - ✘ - - - - - - ✘ ✘ ✘

Sewatec / Sewabloc 43
Waste Water
Dry-installed Volute Casing Pump

Size Installation types


Sewabloc Sewabloc-vertical Sewatec Sewatec-vertical

Bearing bracket

Impeller type

BLOC BLOC-V BLOC-VF Fig.0 3EN 3ENH 3HZ 3HM 3HVG-N 3HVG-NH V VU VGW
500-632 S08 K - - - ✘ ✘ ✘ - - ✘ ✘ ✘ ✘ ✘
500-710 S09 K - - - - - - - - - - ✘ - -
500-900 S09 K - - - - - - - - - - ✘ - -
500-900 S10 K - - - - - - - - - - ✘ - -
600-520 S07 K - - - ✘ - - - - - - ✘ ✘ -
600-710 S08 K - - - ✘ - - - - - - ✘ - -
600-900 S10 K - - - - - - - - - - ✘ - -
700-900 S08 K - - - ✘ - - - - - - ✘ - -

Key to the symbols


Symbol Description
✘ Installation type available
- Installation type not available

44 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Recommended spare parts stock for 2 years' operation to DIN 24296


Quantity of spare parts for recommended spare parts stock
Part No. Description Number of pumps

Replacement part
(including stand-by pumps)
1 2 3 4 5 6 8 10 and more

Spare part

Wear part
163 Discharge cover 1 2 2 2 3 3 4 50 % ✘ - -
210 Shaft 1 1 1 2 2 2 3 30 % ✘ - -
230 Impeller 1 1 1 2 2 2 3 30 % - ✘ -
321.01/02 Rolling element bearing (set) 1 1 1 2 2 3 4 50 % - - ✘
330 Bearing bracket, complete - - - - - - 1 2 pcs. ✘ - -
433.01/02 Mechanical seal, complete (set) 1 2 3 4 4 4 6 90 % - - ✘
Assembly for gland packing 1 1 1 2 2 2 3 40 % - ✘ -
consisting of:
▪ Neck bush
▪ Shaft protecting sleeve
▪ Lantern ring
Packing cord (4 rings) 4 4 6 8 8 9 12 100 % - - ✘
502.01 Casing wear ring 1 2 2 2 3 3 4 50 % - - ✘
503 Impeller ring 1 2 2 2 3 3 4 50 % - - ✘
135 Wear plate 1 2 2 2 3 3 4 50 % - - ✘
Sealing elements (set) 2 4 6 8 8 9 12 150 % - - ✘

Keeping a stock of wear and replacement parts is ▪ Duckfoot bend44)


recommended also during the warranty period.

Sewatec
Scope of supply Depending on the model, the following items are included in
the scope of supply:
Sewabloc
▪ Pump
Depending on the model, the following items are included in
the scope of supply: ▪ Drive
▪ Pump without motor or with directly flanged standardised ▪ Baseplate or soleplate
motor
▪ Coupling and coupling guard
▪ Foundation rails43) ▪ Suction-side double-flanged taper or suction elbow with
▪ Suction-side double-flanged taper or suction elbow with inspection hole
inspection hole ▪ Universal joint shaft
▪ Baseplate or soleplate

43) For horizontal installation


44) For vertical installation

Sewatec / Sewabloc 45
Waste Water
Dry-installed Volute Casing Pump

General assembly drawings with list of components

General assembly drawing: Sewatec with bearing brackets S01, S02, S03, S04

411.02 903.02

903.03
902.01
920.01 903.90 411.90 321.01 330 321.02
411.03

101
932.02
502

914.10 /
906

550.23*

904.01** 940.02

433.02 360.02
230
901.01
903.01
550.01
411.01

163 515 /
932.03 932.20 411.22 183
412.04
412.15 411.46 903.46 433.01 903.22 210
Sewatec with E impeller

Impeller types

230 914.12
230 412.34
230
914.10
550.23
914.24
135
F impeller K impeller D impeller

46 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

900.02
503
920.17 914.10

550.04 260

164.02 940.01

412.05

Inspection hole Option: impeller wear ring (K impeller) Impeller fastening for bearing bracket S04

List of components
Part No. Description Part No. Description
101 Pump casing 502 Casing wear ring
135 Wear plate 503 Impeller wear ring45)
163 Discharge cover 504 Spacer ring
164 Inspection cover 515 Taper lock ring
183 Support foot 550 Disc
210 Shaft 900 Screw
230 Impeller 901 Hexagon head bolt
260 Impeller hub cap 902 Stud
321 Deep groove ball bearing 903 Screw plug
330 Bearing bracket 906 Impeller screw
360 Bearing cover 914 Hexagon socket head cap screw
411 Joint ring 920 Nut
412 O-ring 932 Circlip
433 Mechanical seal 940 Key

45) For K impeller only

Sewatec / Sewabloc 47
Waste Water
Dry-installed Volute Casing Pump

General assembly drawing: Sewatec with bearing brackets S05, S06, S07, S08

Horizontal installation

903.07

903.03 411.07

902.01 903.90
411.03 412.35 920.01 412.11 411.90 636.02 412.02 914.18 320.02 636.03

101
931.01
502
920.21
230
421.02
412.06
433.02 433.01 940.02
906
210
525.04
500.32
412.03
330.12

550.23

940.01 932.02

411.01 183

903.01 932.01 901.64


920.68
550.64
163 932.03 504.52 412.24 903.22 903.46 330.11 421.01 322.01 500.31
411.22 411.46

Sewatec with E impeller — horizontal installation, shaft sealed by mechanical seal

Impeller types
X
502* 914.12
412.34
230

13-6** 914.10
550.23
914.24

135
F impeller K impeller D impeller
(* Not for 100-401.
** For 100-401, 200-400 only.)

48 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

X 260.01
900.02
550.87
920.17 503
901.87
550.04 931.02
164.02 412.03

412.04

Inspection hole Option: impeller wear Impeller fastening for bearing brackets S06 and
ring (K impeller) larger,
except pump size 500-632

List of components
Part No. Description Part No. Description
13-6 Casing insert 502 Casing wear ring
101 Pump casing 503 Impeller wear ring46)
135 Wear plate 504 Spacer ring
163 Discharge cover 525 Spacer sleeve
164 Inspection cover 550 Disc
183 Support foot 636 Lubricating nipple
210 Shaft 900 Screw
230 Impeller 901 Hexagon head bolt
320 Rolling element bearing 902 Stud
322 Radial roller bearing 903 Screw plug
330 Bearing bracket 906 Impeller screw
411 Joint ring 914 Hexagon socket head cap screw
412 O-ring 920 Nut
421 Lip seal 931 Lock washer
432 Auxiliary seal 932 Circlip
433 Mechanical seal 940 Key
500 Ring

46) For K impeller only

Sewatec / Sewabloc 49
Waste Water
Dry-installed Volute Casing Pump

Vertical underfloor installation


901.69 901.18
636.03 320.02 931.01 920.21 210 680.01 550.69 920.11 940.02 341

500.32
914.24
550.23 550.24

932.02 421.02

500.31 330.12

914.18
932.01
421.01
322.01
330.11
412.02
433.01
636.02
504.52
903.90
411.90 932.03
412.24 903.46
411.46
902.01
920.01 903.22
411.22
903.02
411.02
412.11
903.07
411.07 412.35
163
433.02
940.01 525.04

101 412.06

502 230

412.03
400.03
906
901.01
550.07 903.01
411.01
164.01 901.16
550.16

576.01 550.03 900.01 411.51 139 903.04 901.05* 893.01*


411.04 550.05*

Sewatec with E impeller – pump for underfloor installation, shaft sealed by mechanical seal

* If applicable

Impeller types
X
502* 914.12
412.34
230

13-6** 914.10
550.23
914.24

135
F impeller K impeller D impeller
(* Not for 100-401.
** For 100-401, 200-400 only.)

50 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

X 260.01
900.02
550.87
920.17 503
901.87
550.04 931.02
164.02 412.03

412.04

Inspection hole Option: impeller wear Impeller fastening for bearing brackets S06 and
ring (K impeller) larger,
except pump size 500-632

List of components
Part No. Description Part No. Description
101 Pump casing 504 Spacer ring
139 Suction elbow 525 Spacer sleeve
163 Discharge cover 550 Disc
164 Inspection cover 576 Handle
210 Shaft 636 Lubricating nipple
230 Impeller 680 Guard
322 Radial roller bearing 893 Soleplate
320 Rolling element bearing 900 Bolt/screw
330 Bearing bracket 901 Hexagon head bolt
341 Drive lantern 902 Stud
400 Gasket 903 Screw plug
411 Joint ring 906 Impeller screw
412 O-ring 914 Hexagon socket head cap screw
421 Lip seal 920 Nut
433 Mechanical seal 931 Lock washer
500 Ring 932 Circlip
502 Casing wear ring 940 Key
503 Impeller wear ring47)

47) For K impeller only

Sewatec / Sewabloc 51
Waste Water
Dry-installed Volute Casing Pump

Universal joint shaft design


636.03
320.02 931.01 920.21 210 940.02

500.32

550.23

421.02
932.02

500.31 330.12

914.18
932.01
421.01
322.01
330.11
412.02
433.01
636.02
504.52
903.90
411.90 932.03

412.24 903.46
411.46
902.01
920.01 903.22
411.22
903.02
411.02
412.11
903.07
411.07
412.35
163
433.02

940.01 525.04

101 412.06

502 230

400.03 412.03
906
901.01
550.07 903.01
411.01
164.01
901.16
550.16

576.01 550.03 900.01 411.51 139 903.04 901.05* 893.01*


411.04 550.05*

Sewatec with E impeller – pump with universal joint shaft, shaft sealed by mechanical seal

* If applicable

52 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Impeller types
X
502* 914.12
412.34
230

13-6** 914.10
550.23
914.24

135
F impeller K impeller D impeller
(* Not for 100-401.
** For 100-401, 200-400 only.)

X 260.01
900.02
550.87
920.17 503
901.87
550.04 931.02
164.02 412.03

412.04

Inspection hole Option: impeller wear Impeller fastening for bearing brackets S06 and
ring (K impeller) larger,
except pump size 500-632

List of components
Part No. Description Part No. Description
101 Pump casing 504 Spacer ring
139 Suction elbow 525 Spacer sleeve
163 Discharge cover 550 Disc
164 Inspection cover 576 Handle
210 Shaft 636 Lubricating nipple
230 Impeller 680 Guard
320 Rolling element bearing 893 Soleplate
322 Radial roller bearing 900 Bolt/screw
330 Bearing bracket 901 Hexagon head bolt
341 Drive lantern 902 Stud
400 Gasket 903 Screw plug
411 Joint ring 906 Impeller screw
412 O-ring 914 Hexagon socket head cap screw
421 Lip seal 920 Nut
433 Mechanical seal 931 Lock washer
500 Ring 932 Circlip
502 Casing wear ring 940 Key
503 Impeller wear ring48)

48) For K impeller only

Sewatec / Sewabloc 53
Waste Water
Dry-installed Volute Casing Pump

General assembly drawing: Sewabloc

411.02 903.02 902.01


920.01
903.90 330 210
903.03 411.90 321.01 932.02

411.03

101
433.01
502 433.02
914.10 /
906
550.23*
515 /
904.01**
932.03
230 932.20

800

901.57
920.57
903.01 411.01 163 412.15 412.04 903.46 411.46 903.22 411.22 550.57
901.99
Sewabloc with F impeller

Impeller types

230 914.12 900.02


412.34 920.17
230
550.04
914.10
550.23 164.02

914.24 412.05
135
K impeller D impeller Inspection hole

503

Option: impeller wear ring (K impeller)

List of components
Part No. Description Part No. Description
101 Pump casing 503 Impeller wear ring49)
135 Wear plate 515 Taper lock ring
163 Discharge cover 550 Disc
164 Inspection cover 800 Motor

54 Sewatec / Sewabloc
Waste Water
Dry-installed Volute Casing Pump

Part No. Description Part No. Description


210 Shaft 900 Bolt/screw
230 Impeller 901 Hexagon head bolt
260 Impeller hub cap 902 Stud
321 Deep groove ball bearing 903 Screw plug
330 Bearing bracket 914 Hexagon socket head cap screw
411 Joint ring 920 Nut
412 O-ring 932 Circlip
433 Mechanical seal 940 Key
502 Casing wear ring

49) For K impeller only

Sewatec / Sewabloc 55
01.12.2014
2580.5/18-EN

KSB Aktiengesellschaft
P.O. Box 200743 • 06008 Halle (Saale) • Turmstraße 92 • 06110 Halle (Germany)
Tel. +49 345 4826-0 • Fax +49 345 4826-4699
www.ksb.com

Potrebbero piacerti anche