A K STRUCTURAL SHEET LIST
ABOVE FINISH FLOOR AFF KIPS (1000 LBS) k WB-1 INDICATES WIND BRACE - SEE WIND BRACE ELEVATIONS.
ADDITIONAL ADDN'L, ADD'L KIP PER LINEAR FOOT KLF SHT. NO. SHEET NAME
ADJACENT ADJ. KIP PER SQUARE FOOT KSF S001 ABBREVIATIONS, SYMBOLS & SHEET LIST
AGGREGATE AGGR.
TRUSS INDICATES TRUSS - SEE TRUSS ELEVATIONS.
S002 GENERAL NOTES
ALTERNATE ALT. L
ANCHOR BOLT A.B. S003 GENERAL NOTES
LIGHTWEIGHT CONCRETE LWT. CONC. INDICATES MOMENT CONNECTION -
AND & SEE MOMENT CONNECTION DETAILS. S004 SUPERIMPOSED FLOOR DEAD LOAD DIAGRAMS
ANGLE L LIVE LOAD LL
LONGITUDINAL LONG. S005 FLOOR LIVE LOAD DIAGRAMS
APPROVED APPD.
APPROXIMATE APPROX. LONG LEG HORIZONTAL LLH S006 ROOF DEAD & LIVE LOADS, AND L1 CONSTRUCTION LOAD DIAGRAMS
LONG LEG VERTICAL LLV INDICATES STEEL BEAM SPLICE -
ARCHITECT ARCH. S101 LEVEL P2 - COMPOSITE PLAN
LOW POINT L.P. SEE STRUCTURAL STEEL SIMPLE BEAM CONNECTION DETAILS SBX-1.
ARCHITECTURAL ARCH'L
ARCH'L. FINISH SURFACE A.F.S.
S101.1 ENLARGED LEVEL P2 - NORTH
AT @ M S101.2 ENLARGED LEVEL P2 - SOUTH Lake|Flato
INDICATES STRUCTURE OVER VOID - 311 Third Street, San Antonio , Texas 78205
AIR CONDITIONER A/C MANUFACTURE(R) MFR. SEE EXPANSIVE CLAY SOIL DETAILS. S101.3 LEVEL P2 TOPPING PLAN - NORTH T:210.227.3335
AIR HANDLING UNIT AHU MASONRY OPENING M.O. S101.4 LEVEL P2 TOPPING PLAN - SOUTH www.LakeFlato.com
MATERIAL MAT., MAT'L
B MAXIMUM MAX. S102 LEVEL P1 - COMPOSITE PLAN Shepley Bulfinch Richardson & Abbott
MECHANICAL MECH., MECH'L INDICATES THAT COLUMN STARTS UPWARD FROM THIS LEVEL. S102.1 ENLARGED LEVEL P1 - NORTH 2 Seaport Lane, Boston, Massachusetts 02210
BACK FACE B.F. T:617.423.1700
BACK TO BACK MEZZANINE MEZZ.
B. TO B. S102.2 ENLARGED LEVEL P1 - SOUTH www.ShepleyBulfinch.com
MIDDLE MID.
BASEMENT BSMT.
MINIMUM MIN. INDICATES THAT COLUMN STOPS AT THIS LEVEL. S102.3 LEVEL P1 SLAB SLOPE PLAN - NORTH
BEAM BM.
MISCELLANEOUS MISC. S102.4 LEVEL P1 SLAB SLOPE PLAN - SOUTH
BEARING BRG.
MOMENT M
BELOW FINISH FLOOR BFF M.C. OR S103 LEVEL 1 - COMPOSITE PLAN
BETWEEN BTWN. MOMENT CONNECTION(S)
BEVEL (ED) BEV ('D) S103.1 ENLARGED LEVEL 1 - NORTH
BLOCK BLK. N S103.2 ENLARGED LEVEL 1 - SOUTH
BLOCKING
BLOCK-OUT
BLKG.
B.O.
NEAR FACE
NOMINAL
N.F.
NOM.
STRUCTURAL SYMBOLS S104
S104.1
LEVEL 2 - COMPOSITE PLAN
ENLARGED LEVEL 2 - NORTH PROJECT CONSULTANT
BOTTOM BOT. NON-SHRINK N.S. THE FOLLOWING SYMBOLS ARE USED TO REPRESENT THE MATERIALS SHOWN ON THE
BRACKET BRKT. NOT IN CONTRACT N.I.C. STRUCTURAL DRAWINGS. SEE SPECIFICATIONS AND GENERAL NOTES FOR MATERIAL S104.2 ENLARGED LEVEL 2 - SOUTH
BRICK LEDGE ELEVATION B.L.E. NOT TO SCALE N.T.S. QUALITIES REQUIRED. S104.3 ENLARGED LEVEL 2 - SOUTH
BRIDGING BRDG. NUMBER NO. OR #
BUILDING BLDG. S105 LEVEL 3 - COMPOSITE PLAN
BUILDING LINE B.L. O S105.1 ENLARGED LEVEL 3 - NORTH
PROJECT CONSULTANT
ARCHITECTURAL FINISHED SURFACE S105.2 ENLARGED LEVEL 3 - SOUTH
C ON CENTER O.C. A.F.S.
OPENING(S) OPNG(S). S106 LEVEL 4 - COMPOSITE PLAN
CANTILEVER CANT. OPPOSITE OPP., OPPO.
CAST IRON C.I. S106.1 ENLARGED LEVEL 4 - NORTH
OPPOSITE HAND O.H. CAST-IN-PLACE CONCRETE
CAST-IN-PLACE C.I.P. OUTSIDE FACE O.F. S106.2 ENLARGED LEVEL 4 - SOUTH
OF T
CEILING CLG. OUTSIDE DIAMETER O.D. S107 LEVEL 5 - COMPOSITE PLAN TE EX
A A
CENTER LINE C.L. OUTSTANDING OSTG.

T
S107.1 ENLARGED LEVEL 5 - NORTH

S
CENTER OF GRAVITY C.G. STRUCTURAL PRECAST CONCRETE
CENTER OF GRAVITY OF STEEL C.G.S. P S107.2 ENLARGED LEVEL 5 - SOUTH
CENTER TO CENTER C. TO C. S108 LEVEL 6 - COMPOSITE PLAN JOELLE S. ROSENTSWIEG
CHANNEL C PAN P
PARALLEL PAR. S108.1 ENLARGED LEVEL 6 - NORTH

R
CLEAR OR CLEARANCE CLR. SAND GRAVEL, OR LOW P.I. FILL

PR
89451

E
COLUMN COL. PARTITION PARTN. S108.2 ENLARGED LEVEL 6 - SOUTH

E
L

O
IC D
ENSE

N
F
COMPRESSION C OR COMP. PENETRATION PEN. E
S G
PERPENDICULAR PERP. S109 ROOF - COMPOSITE PLAN S
ONAL E
N
CONCRETE CONC.
CONCRETE MASONRY UNIT CMU PIECE PC. EARTH S109.1 ENLARGED ROOF PLAN - NORTH
CONNECTION (S) CONN(S). PLATE PL. S109.2 ENLARGED ROOF PLAN - SOUTH
CONTINUOUS CONT. POINT PT.
CONTRACTOR CONTR. POUNDS PER SQUARE FOOT PSF S109.3 PV ARRAY FRAMING
POUNDS PER SQUARE INCH PSI ROCK
CONTROL JOINT CT.JT., CJ S110 HIGH ROOF FRAMING PLAN
CONSTRUCTION CONST. PRECAST CONCRETE P/C
S200 COMMON SCHEDULES & DETAILS
CONSTRUCTION JOINT C.J. PRE-ENGINEERED
CORNER COR., CNR. BUILDING MANUFACTURER PEBM ARCHITECTURAL PRECAST CONCRETE
S201 MAT SLAB FOUNDATION DETAILS
COVER CVR. PRE-ENGINEERED S202 MAT SLAB FOUNDATION DETAILS
COVER PLATE COV. PL. METAL BUILDING PEMB
PREFABRICATED PREFAB. S203 MAT SLAB FOUNDATION DETAILS
D PRELIMINARY PRELIM. NON-SHRINK GROUT S211 BASEMENT WALL SCHEDULE & SECTIONS
PROJECTION PROJ. S212 BASEMENT WALL DETAILS
DETAIL DET., DET'L
DEAD LOAD DL R
S213 BASEMENT WALL DETAILS
DEFORMED BAR ANCHOR D.B.A. SAND CEMENT GROUT S214 BASEMENT WALL SECTIONS & DETAILS
DIAGONAL DIAG. RADIUS R
DIAMETER DIA. REFER REF. S215 BASEMENT WALL SECTIONS & DETAILS
DIMENSION(S) DIM(S)., DIM'S REINFORCED CONCRETE PIPE RCP S221 RAMP PLANS AND SECTION
DOVETAIL DVTL. REINFORCE(ING) (ED) (MENT) REINF. EXISTING
REMAINDER REM. OR R
S222 RAMP DETAILS
DOWNSPOUT DS.
DRAWING(S) DWG(S)., DWG'S REQUIRE REQ. S301 COLUMN SCHEDULE
DOUBLE DBL. RETENTION SYSTEM RET. SYS. 1 S302 COLUMN TYPICAL DETAILS
DOWEL(S) DWL(S). REQUIRED REQ'D. C.M.U.
RISER RIS. S302A COLUMN TYPICAL DETAILS
E ROOF RF. S303 COLUMN TYPICAL DETAILS
ROOF DRAIN R.D. S304 COLUMN STUD RAIL DETAILS
EACH EA. ROOF OPENING RF. OPNG.
EACH FACE E.F. ROOM RM. S311 SHEAR WALL ENLARGED PLANS
EACH WAY E.W. BRICK
ROUND RND. S312 SHEAR WALL TYPICAL DETAILS
EDGE ANGLE OFFSET E.A.O.
ELECTRICAL ELEC. S321 STAIR & BLEACHER DETAILS
S
ELEVATION EL., ELEV. S322 PLANTER WALL DETAILS 1 09/26/2013 ADDENDUM #2
ELEVATOR ELEV. SCHEDULE(D) SCHED., SCH. STRUCTURAL STEEL
SECTION SECT.
S401 LEVEL P1 POST-TENSIONED SLAB SCHEDULE NO. DATE DESCRIPTION
ENGINEER ENGR. REVISIONS
ENTRANCE ENT. SHEAR V S402 LEVEL P1 DETAILS
EQUAL EQ. SHEET SHT. S403 LEVEL P1 DETAILS
EQUIPMENT EQUIP. SIDEWALK SW.
SIMILAR SIM. WOOD (CONTINUOUS) S411 LEVEL 1 & PLAZA SLAB TYPICAL DETAILS
EXPANSION EXP.
EXPANSION JOINT E.J. SPACE, SPACING SPA. S412 CONCRETE BEAM SCHEDULE - LEVEL 1 & PLAZA
EXISTING EXIST. SPECIFICATION(S) SPEC(S) S413 LEVEL 1 & PLAZA DETAILS
EXTERIOR EXT. SPECIFIED SPEC'D. WOOD (NON-CONTINUOUS)
SQUARE FOOT (FEET) S.F. S414 LEVEL 1 & PLAZA DETAILS
EXTRA STRONG X-STR.
STANDARD STD., STND S415 LEVEL 1 & PLAZA DETAILS
F STEEL STL. S416 LEVEL 1 & PLAZA DETAILS
STIFFENER STIFF. PLYWOOD
FACE TO FACE F. TO F. STRAIGHT STR. S417 LEVEL 1 & PLAZA DETAILS
FABRICATOR FABR. STIRRUPS STIR. S418 LEVEL 1 & PLAZA TRANSFER GIRDER TYPICAL DETAILS
FAR SIDE F.S. STRUCTURE STRUCT.
FIELD VERIFY (F.V.) GLUE LAMINATED LUMBER (GLU-LAM) S419 LEVEL 1 & PLAZA TRANSFER GIRDER TYPICAL DETAILS
STRUCTURAL STRUCT'L.
FINISH(ED) FIN. SYMMETRICAL SYM. S501 CONCRETE & POST TENSIONED BEAM SCHEDULE TYPICAL DETAILS
FINISHED FLOOR FIN. FL. SUBCONTRACTOR SUBCONTR. S502.1 CONCRETE BEAM SCHEDULE
FIREPROOF(ING) FP. SUPPORT(S) SUPT(S).
FLANGE FLG. MICRO LAMINATED LUMBER (MICRO-LAM) S502.2 CONCRETE BEAM SCHEDULE
FLOOR FL. T 1 S502.3 CONCRETE BEAM SCHEDULE
FLOOR DRAIN F.D.
TAPERED BEAM T.B. S502.4 CONCRETE BEAM SCHEDULE
FOUNDATION FDN. KEY PLAN
TEMPERATURE TEMP. RTU S503 TYPICAL CONCRETE BEAM DETAILS
ROOF TOP MECHANICAL UNIT ON PLAN
G TENSION T ___#
S504 TYPICAL WIDE PAN JOIST DETAILS CITY OF AUSTIN
TERRAZZO TERR.
GAGE OR GAUGE GA. THICK, THICKNESS TH., THK. S505 PAN JOIST SCHEDULE AND TYPICAL DETAILS
GALVANIZED GALV. TONGUE & GROOVE T&G S506 CONCRETE SECTIONS AND DETAILS
GALVANIZED IRON G.I. TOP AND BOTTOM T&B
GALVANIZED STEEL G.S. TOP OF T.O. BEAM BOTTOM CHORD BRACING ON PLAN
S507 CONCRETE SECTIONS AND DETAILS
OWNER
GENERAL CONTRACTOR G.C. TOP OF BEAM T.O.B. S511 CONCRETE SECTIONS AND DETAILS
GOVERNMENT
GRADE
GOVT.
GR.
TOP OF FOOTING T.O.F. S512 CONCRETE SECTIONS AND DETAILS NEW CENTRAL LIBRARY
TOP OF PIER T.O.P.
GRADE BEAM GR. BM. TOP OF PIER CAP T.O.P.C. S513 CONCRETE SECTIONS AND DETAILS CIP ID#7235.001
GEN. CONTR. TOP OF RETAINING WALL T.R.W. S514 CONCRETE SECTIONS AND DETAILS W. CESAR CHAVEZ BLVD.
H TOP OF STEEL T.O.S. S601 COMPOSITE STEEL BEAM DETAILS
TOP OF STRUCTURAL CONCRETE T.O.S.C. PROJECT
AUSTIN, TX
HEADED STUDS H.S. S602 SIMPLE BEAM CONNECTION DETAILS
HEIGHT HT. TOP OF WALL T.O.W.
HIGH POINT H.P. TREAD TR. S603 WIND BRACE DETAILS
HOLLOW STRUCTURAL SHAPE HSS TUBE STEEL
TYPICAL
TS
TYP.
S604 WIND BRACE ELEVATIONS ABBREVIATIONS, SYMBOLS &
HORIZONTAL HORIZ. S611 EXTERIOR WALL SECTIONS AND DETAILS
HOOK HK. SHEET LIST
U S612 LOW ROOF SECTIONS & DETAILS
DRAWING TITLE
I S613 LOW ROOF SECTIONS & DETAILS
CIP ID#7235.001

UNLESS NOTED OTHERWISE U.N.O.


INFORMATION INFO. S614 HIGH ROOF SECTIONS & ELEVATIONS
INSIDE DIAMETER I.D. V
S615 HIGH ROOF SECTIONS & DETAILS
INSIDE FACE I.F. VERTICAL VERT.
INTERIOR INT. S616 HIGH ROOF SECTIONS & DETAILS
INTERMEDIATE INTERM. W S701 READING PORCH AND SCRIM SECTIONS AND DETAILS
WATERSTOP WS.
S702 READING PORCH AND SCRIM SECTIONS AND DETAILS
J
WATERPROOFING WPFG. S703 EAST CANOPY AT ATRIUM SECTIONS AND DETAILS
JOINT(S) JT(S). WELDED WIRE MESH W.W.M. S704 SOUTH CANOPY SECTIONS AND DETAILS
JOIST(S) JST(S). WIND BRACE WB
WIND LOAD W.L. S705 NORTH CANOPY SECTIONS AND DETAILS
WINDOW WDW. S706 WEST CANOPY SECTION AND DETAILS 1/8" = 1'-0" 08/16/13
WITH W/ S801 ATRIUM STAIR DETAILS
SCALE DATE

WORK POINT W.P.


3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

WOOD WD. S802 ATRIUM BRIDGE SECTIONS AND ELEVATIONS JOB NUMBER

WROUGHT IRON W.I. S803 ATRIUM BRIDGE SECTIONS AND ELEVATIONS


TJR JSR
S804 ATRIUM BRIDGE SECTIONS AND ELEVATIONS DRAWN CHECKED
NEW CENTRAL LIBRARY

S805 ATRIUM BRIDGE SECTIONS AND ELEVATIONS PACKAGE 2 CONSTRUCTION DOCUMENTS

S001
9/26/2013 8:29:53 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
1
CODES & DESIGN SPECIFICATIONS FIRE RESISTANCE CONCRETE REINFORCEMENT CAST-IN-PLACE CONCRETE
1
1. BUILDING CODE: 2009 INTERNATIONAL BUILDING CODE. 1. THE STRUCTURAL SYSTEM AND CONSTRUCTION DETAILS ARE DESIGNED TO COMPLY WITH THE 1. CONCRETE REINFORCING FABRICATOR AND INSTALLER SHALL INCLUDE IN BASE BID AN ALLOWANCE FOR UP 1. CONTRACTOR SHALL INCLUDE IN BASE BID A CONTINGENCY OF $30,000.00 FOR ADDITIONAL CONCRETE TO BE
REQUIREMENTS OF THE FOLLOWING: TO 15 TONS OF MISCELLANEOUS REINFORCING STEEL TO BE INSTALLED IN THE FIELD AS DIRECTED BY THE USED IN THE FIELD AS DIRECTED BY THE ARCHITECT/ENGINEER. ALLOWANCE SHALL COVER ALL COSTS
2. STRUCTURAL STEEL: AISC 360-05 "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS". FLOOR ASSEMBLY: 2 HOURS ENGINEER. ALLOWANCE SHALL COVER ALL COSTS INCLUDING MATERIAL, DETAILING, FABRICATION, INCLUDING FORMWORK, DETAILING, MATERIAL, LABOR, TRANSPORTATION AND FINISHING. ANY UNUSED
ROOF ASSEMBLY: 1 HOUR TRANSPORTATION AND PLACEMENT. ANY UNUSED PORTION OF ALLOWANCE SHALL BE CREDITED TO THE PORTION OF ALLOWANCE SHALL BE CREDITED TO THE OWNER AT A UNIT COST PER CUBIC YARD FOR EACH
3. STRUCTURAL CONCRETE: "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI-318-08," THE STRUCTURAL FRAME: 4 HOURS OWNER AT A UNIT COST PER TON ESTABLISHED DURING BIDDING. APPLICATION TO BE ESTABLISHED DURING BIDDING.
AMERICAN CONCRETE INSTITUTE. EXTERIOR BEARING WALLS: 4 HOURS
INTERIOR BEARING WALLS: 4 HOURS 2. REINFORCING STEEL SHALL BE NEW OR RECYCLED DOMESTIC DEFORMED BILLET STEEL, CONFORMING TO 2. CONSTRUCTION JOINTS IN BEAMS, SLABS AND WALLS SHALL ONLY OCCUR WITHIN 2'-0" OF MIDSPAN
4. STRUCTURAL MASONRY" "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-08)," THE ASTM A615, GRADES AS FOLLOWS: BETWEEN SUPPORTS. SUBMIT SLAB DIAGRAMS SHOWING PROPOSED CONSTRUCTION JOINT LOCATIONS FOR
AMERICAN CONCRETE INSTITUTE. 2. STRUCTURAL FRAME CONSISTS OF COLUMNS AND MEMBERS FRAMING INTO COLUMNS, INCLUDING GIRDERS, #3 THROUGH #6 .........................GRADE 60 ALL FLOOR LEVELS (REFER TO SPECIFICATIONS).
BEAMS AND BRACING. #7 THROUGH #18 .......................GRADE 75
5. STRUCTURAL WOOD: "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION NDS)," THE AMERICAN 3. COLUMN PILASTERS ON THE SIDES OF WALLS SHALL BE CAST MONOLITHICALLY WITH THE WALL UNLESS
FOREST AND PAPER ASSOCIATION. 3. THE STRUCTURAL FLOOR AND ROOF FRAMING IS CONSIDERED TO BE "RESTRAINED" IN ACCORDANCE WITH 3. REINFORCING STEEL SHALL BE CERTIFIED AS HAVING MET THE BEND REQUIREMENTS OF ASTM A615. SHOWN OTHERWISE.
THE U.L. "FIRE RESISTANCE DIRECTORY," FOR PURPOSES OF ESTABLISHING THE FIRE RESISTANCE RATING.
4. REINFORCING STEEL SHOWN IN SECTIONS OF BEAMS, WALLS AND COLUMNS IS SCHEMATIC INDICATION THAT 4. SLEEVES, MECHANICAL OPENINGS, CONDUITS, PIPES, RECESSES, DEPRESSIONS, CURBS AND ALL
4. STEEL BEAMS WHICH ARE LIGHTER THAN THE MINIMUM SIZE SET FORTH IN THE REFERENCED U.L. ASSEMBLY REINFORCING EXISTS. SEE SCHEDULES, SECTION NOTES AND DETAILS, AND GENERAL NOTES FOR ACTUAL EMBEDDED ITEMS SHALL BE PROVIDED FOR AS SHOWN ON THE ARCHITECTURAL AND MECHANICAL
GENERAL SHALL RECEIVE ADDITIONAL SPRAYED FIREPROOFING AS REQUIRED TO ACHIEVE THE DESIGNATED RATING. REINFORCING REQUIRED. DRAWINGS AND AS REQUIRED BY EQUIPMENT MANUFACTURERS. MINIMUM CONCRETE BETWEEN
SLEEVES SHALL BE 6". INSTALLATION OF THESE ITEMS SHALL BE COORDINATED WITH SHOP DRAWINGS Lake|Flato
THE FOLLOWING GENERAL NOTES CONSTITUTE A MAJOR PART OF THE PLANS AND SPECIFICATIONS. STRICT 5. REFER TO DOWEL SCHEDULE ON SHEET S200 FOR ALL LAP SPLICE BARS AND HOOKS INDICATED ON THE OF TRADES REQUIRING THESE ITEMS. 311 Third Street, San Antonio , Texas 78205
COMPLIANCE WITH THESE NOTES IS ESSENTIAL TO THE PROPER CONSTRUCTION OF THE BUILDING. PAVER & TOPPING SLAB FILL MATERIAL DRAWINGS. T:210.227.3335
5. SET FORMS TO FOLLOW SLOPES AND GRADES DEFINED ON PLAN, KEEPING MEMBER DEPTHS CONSTANT AT www.LakeFlato.com
1. REFER TO THE PLAN NOTES FOR ADDITIONAL REQUIREMENTS. 1. PAVER SYSTEMS AT PLAZA AND ROOF GARDEN AND NON-STRUCTURAL BUILT-UP SLABS WITHIN THE 6. DETAIL REINFORCING BARS AND PROVIDE BAR SUPPORTS AND SPACERS IN ACCORDANCE WITH THE ACI DEPTHS DETAILED OR SCHEDULED, UNLESS SPECIFICALLY NOTED OTHERWISE. SLOPE UNIFORMLY BETWEEN
BUILDING SHALL BE SUPPORTED ON A LIGHTWEIGHT HIGH DENSITY EXTRUDED POLYSTYRENE INSULATION. DETAILING MANUAL. ELEVATIONS GIVEN. BUILD IN CAMBER WHERE SPECIFIED. Shepley Bulfinch Richardson & Abbott
2. THE DETAILS IN THE DRAWINGS, WHICH ARE DESIGNATED AS "TYPICAL DETAILS", APPLY GENERALLY TO THE 2 Seaport Lane, Boston, Massachusetts 02210
2. INSULATION MATERIAL SHALL COMPLY WITH ASTM C578 “STANDARD SPECIFICATION FOR RIGID, CELLULAR 7. WHERE BAR TYPES FROM THE BAR BENDING DIAGRAMS ARE SPECIFIED, PROVIDE BARS ACCORDINGLY. 6. AT PARKING, SET FORMS AND FINISH SLABS TO PROVIDE A MINIMUM OF 7'-2" CLEAR HEADROOM AFTER T:617.423.1700
CONSTRUCTION IN ALL AREAS WHERE THE CONDITIONS ARE SIMILAR TO THOSE DESCRIBED IN THE DETAILS, www.ShepleyBulfinch.com
REGARDLESS OF WHETHER OR NOT THE DETAILS ARE SPECIFICALLY REFERENCED IN THE DRAWINGS. POLYSTYRENE THERMAL INSULATION”, TYPE VII OR V. OTHERWISE, DETAIL BARS IN BEAMS, COLUMNS, SLABS, AND WALLS AS FOLLOWS: FORM REMOVAL. PROVIDE 8'-4" MINIMUM CLEAR HEADROOM ABOVE HANDICAP VAN ACCESSIBLE RAMPS AND
PARKING. NOTIFY ENGINEER OF ANY CLEARANCE CONCERNS PRIOR TO CONCRETE CASTING OPERATIONS.
3. SEE "EARLY EXCAVATION PACKAGE 1B" FOR EXCAVATION AND TEMPORARY RETAINING SYSTEM 3. INSULATION SHALL COMPLY WITH THE 2009 INTERNATIONAL BUILDING CODE (IBC). A. RUN TOP AND BOTTOM BARS CONTINUOUS, WITH SPLICES AND HOOKS AS DESCRIBED BELOW.
REQUIREMENTS. 7. ALL CONDUITS AND PIPES EMBEDDED IN CONCRETE SHALL COMPLY WITH ALL PROVISIONS SPECIFIED IN
1 4. INSULATING FILL AT THE PLAZA AND ROOF GARDEN SHALL HAVE A COMPRESSIVE STRENGTH EQUAL TO OR B. PROVIDE STANDARD 90 DEGREE HOOK ON TOP BARS AT CANTILEVER ENDS. ACI 318, SECTION 6.3, WITH THE FOLLOWING SPECIFIC REQUIREMENTS:
4. SEE ARCHITECTURAL DRAWINGS FOR LOCATION OF FLOOR DROPS, FLOOR SLOPES, CURBS, MISCELLANEOUS GREATER THAN 100 PSI. INSULATING FILL FOR INTERIOR BUILT-UP SLABS SHALL HAVE A COMPRESSIVE
ELEVATIONS, DETAILS AND DIMENSIONS NOT SHOWN ON PLAN. STRENGTH EQUAL TO OR GREATER THAN 60 PSI. C. SPLICE TOP AND INTERMEDIATE BARS AT THE CENTER LINE BETWEEN MEMBER SUPPORTS, A. THE MAXIMUM OUTSIDE DIAMETER OF THE CONDUITS AND PIPES SHALL BE 1 1/2". NONE
UNLESS NOTED OTHERWISE. PERMITTED IN SLABS THINNER THAN 4 1/2".
5. SLEEVES AND BLOCKOUTS REQUIRED FOR PASSAGE OF DUCTWORK, PIPING DRAINS, CONDUIT, ETC., AND 5. PLAZA AND ROOF GARDEN INSULATION SHALL BE CAPABLE OR SUPPORTING 500 PSF SUSTAINED DEAD
ANCHORS REQUIRED FOR ANCHORING EQUIPMENT AND PIPING ARE NOT GENERALLY INDICATED ON THE LOAD PLUS 100 PSF LIVE LOAD WITH A MAXIMUM LONG TERM DEFLECTION (INCLUDING CREEP) NOT TO D. SPLICE BOTTOM BARS DIRECTLY OVER MEMBER SUPPORTS, UNLESS NOTED OTHERWISE. B. THE MINIMUM CLEAR DISTANCE BETWEEN CONDUITS AND PIPES SHALL BE 6". PROJECT CONSULTANT

STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL DETERMINE SUCH REQUIREMENTS FROM OTHER SERIES EXCEED 1/2 INCH.
DRAWINGS. SUBCONTRACTORS, AND SUPPLIERS AND SHALL COORDINATE THE LOCATIONS AND DETAILS FOR E. SPLICE VERTICAL BARS IN WALLS ONLY AT FLOOR LINES, UNLESS NOTED OTHERWISE. C. AT FORMED SLABS, LOCATE IN MIDDLE THIRD OF SLAB THICKNESS BETWEEN THE TOP AND
THESE ITEMS PRIOR TO FABRICATION OR CONSTRUCTION OF THE STRUCTURE. ANY CONFLICTS BETWEEN THESE 6. DENSITY OF INSULATION MATERIAL SHALL NOT EXCEED 5 PCF. HORIZONTAL BARS SHALL BE SPLICED AS SPECIFIED FOR TOP, BOTTOM, AND BOTTOM MAT OF REINFORCING. AT BEAMS, LOCATE INSIDE BEAM STIRRUP. IN JOISTS, LOCATE AT
ITEMS AND THE BUILDING STRUCTURE SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR INTERMEDIATE BARS OF BEAMS. CENTER LINE, AT LEAST 6" FROM BOTTOM.
RESOLUTION. 7. INSULATING FILL SHALL RETAIN STRUCTURAL PROPERTIES WITHIN A TEMPERATURE RANGE OF 0° F TO 125° F.
6. VERIFY AND/OR ESTABLISH LOCATIONS AND DIMENSIONS OF ALL FRAMED OPENINGS RELATED TO EQUIPMENT F. CENTER BARS NOTED AS "AT SUPT'S." OVER MEMBER SUPPORTS, AND CENTER BARS NOTED AS D. NONE PERMITTED IN COLUMNS WITHOUT PRIOR APPROVAL.
PROJECT CONSULTANT
OR DUCTWORK, INCLUDING INSULATION, IF ANY, WHERE SUBSTANTIAL RELOCATION OR RECONFIGURATION IS "BTWN. SUPT'S." BETWEEN SUPPORTS.
REQUIRED, SUBMIT A DRAWING TO THE ARCHITECT FOR REVIEW. CONCRETE MIX E. DO NOT DISPLACE REINFORCING STEEL FROM ITS PROPER POSITION.
G. PLACE BARS NOTED AS "2ND LAYER" BELOW THE PRIMARY TOP BARS (OR ABOVE THE PRIMARY
7. MATERIALS OR PRODUCTS SUBMITTED FOR APPROVAL WHICH ARE NOT SPECIFIED IN THE DOCUMENTS SHALL BE 1. PROVIDE CONCRETE HAVING THE FOLLOWING GENERAL CHARACTERISTICS: BOTTOM BARS) AND PROVIDE #11 SPACER BARS PLACED AT INTERVALS OF 4'-0" BETWEEN 8. SLEEVES OR PIPES PASSING HORIZONTALLY THROUGH BEAMS OR JOISTS MUST BE LOCATED IN THE MIDDLE
ACCOMPANIED BY A CURRENT I.C.B.O. (INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS) REPORT. THE TWO LAYERS OF BARS. THIRD OF THE SPAN AND WITHIN THE MIDDLE THIRD OF THE BEAM DEPTH. MAXIMUM DIAMETER SHALL BE ONE
MATERIALS OR PRODUCTS THAT DO NOT HAVE I.C.B.O. REPORTS INDICATING THE SUBSTITUTED MATERIAL OR COMPRESSIVE MAX. THIRD OF THE MEMBER DEPTH. SPACE AT LEAST 3 DIAMETERS CLEAR APART AND ADD ONE STIRRUP EACH OF T
PRODUCT TO BE EQUAL TO THAT SPECIFIED, WILL NOT BE CONSIDERED. STRENGTH SLUMP AGG. SIZE H. ALL BAR SPLICES IN BEAMS, SLABS, AND WALLS SHALL COMPLY WITH THE LAP SCHEDULE ON SHEET SIDE OF EACH SLEEVE. TE EX
A A

T
CLASS (PSI) (IN) TYPE (IN.) USAGE S200. ALL SPLICES SHALL BE "TENSION SPLICES" UNLESS NOTED OTHERWISE.

S
9. PROVIDE CAMBERED FORMWORK FOR THOSE MEMBERS SHOWN ON PLAN TO BE CAMBERED.
DESIGN LOADS: A 3,000 @ 28 DAYS 6-8 HDRK 1 MUDSLAB & FIBER-REINFORCED WORKSLAB I. SPLICE VERTICAL BARS IN COLUMNS ONLY AT FLOOR LINES, UNLESS NOTED OTHERWISE.
COLUMN BAR SPLICES SHALL BE CLASS C FOR TENSION WITH 100 PERCENT SPLICING. 10. PROVIDE SHEAR KEYS IN ALL CONSTRUCTION JOINTS IN BEAMS AND WALLS, IN ACCORDANCE WITH THE JOELLE S. ROSENTSWIEG
1. DEAD LOADS INCLUDE THE WEIGHT OF THE STRUCTURAL COMPONENTS AND ALLOWANCES FOR PERMANENT B 3,500 @ 28 DAYS 3-5 HDRK 1 P2 TOPPING, ARCHITECTURAL TOPPING & CONCRETE TYPICAL DETAILS.

R
PR
PARTITIONS, PERMANENT FIXTURES, FINISHED, ROOFING, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE BUILT-UP SLAB J. PLACE A COLUMN TIE 3" ABOVE THE TOP OF THE FOUNDATION OR INTERSECTING SLAB AT ANY 89451

E
E
L
LEVEL AND 3" BELOW THE LOWEST HORIZONTAL REINFORCING IN THE SLAB OF THE FLOOR 11. DOCK HEIGHT GRADE BEAMS SHALL BE BRACED FROM THE EXTERIOR DIRECTION PRIOR TO PLACING FILL.

O
PROTECTION MATERIALS SHOWN OR SPECIFIED. IC
ENSE
D

N
F
E
C 5,000 @ 28 DAYS 6-8 HDRK 1 1/2 CRANE FOUNDATIONS OR ROOF FRAMING ABOVE AND SPACE TIES AS REQUIRED IN BETWEEN. WHERE BEAMS BRACING AND SHALL REMAIN IN PLACE UNTIL THE FLOOR SLAB HAS BEEN POURED AND HAS CURED FOR AT S
S N
G
ONAL E
2. SEE DEAD LOAD DIAGRAMS FOR SCHEMATIC LOADING LOCATIONS. FRAME FROM FOUR DIFFERENT DIRECTIONS INTO A COLUMN, TIES MAY BE TERMINATED LEAST 7 DAYS.
D 5,000 @ 56 DAYS 6-8 HDRK 1 1/2 MAT SLAB FOUNDATION WITHIN THE FLOOR FRAMING 3" BELOW THE LOWEST HORIZONTAL REINFORCING IN THE
3. LOADINGS FOR MECHANICAL ROOMS ARE BASED ON THE WEIGHTS OF ASSUMED EQUIPMENT, AS INDICATED ON SHALLOWEST BEAM. TOP OF COLUMNS SUPPORTING STRUCTURAL STEEL SHALL HAVE 3 TIES 12. PLACE WATERSTOPS IN ALL EXTERIOR CONSTRUCTION JOINTS BELOW GRADE AND ELSEWHERE AS CALLED
THE MECHANICAL DRAWINGS (INCLUDING THE WEIGHT OF CONCRETE PADS, WHERE INDICATED). ANY CHANGES E 5,000 @ 28 DAYS 3-5 HDRK 3/4 FLOOR FRAMING FOR LEVELS L2 AND ABOVE AT 3" O.C. STARTING 3" BELOW THE TOP OF THE COLUMN. FOR. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION.
IN TYPE, SIZE, LOCATION OR NUMBER OF PIECES OF EQUIPMENT SHOULD BE REPORTED TO THE ARCHITECT FOR
VERIFICATION OF THE ADEQUACY OF SUPPORTING MEMBERS PRIOR TO THE PLACEMENT OF SUCH EQUIPMENT. F 6,000 @ 28 DAYS 3-5 HDRK 3/4 COLUMNS AND WALLS, FLOOR FRAMING FOR K. PROVIDE CORNER BARS FOR EACH HORIZONTAL BAR AT THE INSIDE AND OUTSIDE FACES OF 13. FLOORS ARE NOT DESIGNED TO SUPPORT FORMWORK AND WET CONCRETE WEIGHT OF NEXT LEVEL.
LEVELS L1 AND P1, RAMP FRAMING INTERSECTING BEAMS OR WALLS. REFER TO TYPICAL CORNER BAR DETAILS. CONTRACTOR SHALL DESIGN AND PROVIDE RESHORING TO PREVENT OVERSTRESSING THE STRUCTURE.
4. DESIGN LIVE LOADING IS AS FOLLOWS:
AUTOMOBILE PARKING ................................................................................40 PSF G 3,000 @ 28 DAYS 3-5 LTWT 3/4 COMPOSITE SLABS AT MEZZANINES & BLEACHERS 8. BARS SHOWN IN THE SCHEDULES TO HOOK AT DISCONTINUOUS ENDS SHALL HAVE THE HOOK PLACED 14. HOUSEKEEPING PADS UNDER MECHANICAL EQUIPMENT, IF ANY, ARE SHOWN AND SPECIFIED ON THE
AUTOMOBILE PARKING WHEEL LOAD ......................................................... 3,000 LBS HORIZONTALLY AT EXTERIOR CORNERS. MECHANICAL DRAWINGS. REINFORCE TOP OF HOUSEKEEPING PAD WITH #3'S AT 8" ON CENTER MAXIMUM EACH
GARAGE IMPACT LOAD............................................................................... 6,000 LBS WAY, UNLESS SHOWN OTHERWISE ON MECHANICAL DRAWINGS.
EXTERIOR PLAZA AND SIDEWALKS ............................................................150 PSF 2. WORKABILITY ADMIXTURES MAY BE UTILIZED, PROVIDED THAT BATCH PROPORTIONS ARE DETERMINED IN THE 9. PROVIDE NO. 3 DOWELS X 2'-0" AT 1'-6" ON CENTER, WITH A 90 DEGREE HOOK AT ALL EDGES OF
TYPICAL FLOOR SPACE WITH LIBRARY STACKS ....................................... 150 PSF MANNER DESCRIBED IN THE SPECIFICATIONS. CONCRETE SLABS, UNLESS DETAILED OTHERWISE. 15. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO ENSURE COMPLETE CONSOLIDATION OF CONCRETE BEHIND
TYPICAL FLOOR SPACE WITHOUT LIBRARY STACKS ................................ 100 PSF ALL POST-TENSIONING ANCHORAGES.
ATRIUM WALKWAYS, BRIDGES, STAIRWAYS ............................................100 PSF 3. FLY ASH WILL NOT BE PERMITTED IN ARCHITECTURALLY EXPOSED CONCRETE. FLY ASH MAY BE USED 10. REFER TO SLAB TEMPERATURE REINFORCING SCHEDULE FOR TEMPERATURE REINFORCING IN SLABS WHERE
EXTERIOR BALCONIES ..................................................................................100 PSF ELSEWHERE, WITHIN THE SPECIFIED PROPORTION LIMITS, BUT THE CONTRACTOR SHALL FIRST VERIFY NOT SPECIFICALLY DETAILED. 16. GROUT OR CONCRETE CONTAINING CHLORIDES, FLUORIDES, SULFIDES, NITRATES, OR OTHER SUBSTANCES
OTHER PUBLIC SPACES................................................................................ 100 PSF COMPATIBILITY WITH CURING COMPOUNDS, SEALERS, BOND BREAKER, FLOORING ADHESIVES AND OTHER DETRIMENTAL TO PRESTRESSING STEEL SHALL NOT BE USED.
MECHANICAL AND STORAGE ROOMS, KITCHENS ....................................... 150 PSF MATERIALS PROPOSED TO BE IN CONTACT WITH THE CONCRETE. 11. CONCRETE COVER FOR MILD REINFORCING STEEL SHALL BE AS FOLLOWS, MEASURED TO NEAREST BAR,
OCCUPIED ROOFS .........................................................................................100 PSF STIRRUP OR TIE: 17. CONSTRUCTION JOINTS IN POST-TENSIONED MEMBERS OTHER THAN WHERE SHOWN ON THE DRAWINGS
UNOCCUPIED ROOFS ....................................................................................20 PSF 4. PROVIDE FIVE PERCENT (PLUS OR MINUS 1 1/2 PERCENT) AIR ENTRAINMENT IN CONCRETE PERMANENTLY SHALL BE APPROVED BY THE ENGINEER.
MISCELLANEOUS AWNINGS AND CANOPIES ............................................... 20 PSF EXPOSED TO THE WEATHER. USE OF AIR ENTRAINMENT, AND CORRESPONDING REDUCTION OF THE A. AT SLABS-ON-GRADE, BEAM AND WALL SURFACES DEPOSITED AGAINST THE GROUND (WITH OR
WATER/CEMENT RATIO, MUST BE NOTED ON THE MIX DESIGNS. DO NOT USE AIR IN SLABS WHICH HAVE HARD WITHOUT VAPOR RETARDER): 3" 18. ALL POCKETS OR BLOCKOUTS REQUIRED FOR ANCHORAGES SHALL BE ADEQUATELY REINFORCED SO
5. SEE FLOOR LIVE LOAD DIAGRAMS FOR SCHEMATIC LOADING LOCATIONS. TROWEL FINISH. AS NOT TO DECREASE THE STRENGTH OF THE STRUCTURE. ALL POCKETS SHALL BE WATERPROOFED TO
B. AT FORMED FACES OF BEAMS, COLUMNS AND WALLS EXPOSED TO RAIN OR IN CONTACT WITH THE ELIMINATE WATER LEAKAGE THROUGH OR INTO THE POCKET.
6. LIVE LOAD REDUCTIONS, WHERE PERMISSIBLE, ARE COMPUTED IN ACCORDANCE WITH THE BUILDING CODE. 5. USE OF ACCELERATING OR SET-RETARDING ADMIXTURES REQUIRES PRIOR APPROVAL OF THE ARCHITECT. IN GROUND: 2"
GENERAL, USE OF CALCIUM CHLORIDE WILL NOT BE PERMITTED. 19. IF CONCRETE IS PLACED BY THE PUMP METHOD, SUPPORTS SHALL BE PROVIDED TO SUPPORT THE HOSE.
7. KITCHEN AREA DESIGN LIVE LOAD INCLUDE AN ALLOWANCE FOR THE WEIGHT OF KITCHEN EQUIPMENT, SUBMIT C. AT FORMED FACES OF BEAMS AND COLUMNS NOT EXPOSED TO RAIN OR SOIL: 1 1/2" THE HOSE SHALL NOT BE ALLOWED TO RIDE ON THE REINFORCEMENT. CONCRETE SHALL NOT BE DROPPED BY
FINAL LAYOUT SHOWING LOCATION AND WEIGHT OF ALL EQUIPMENT TO THE ENGINEER FOR COMPARISON WITH 6. CEMENT SHALL BE TYPE I OR TYPE II (ASTM C 150), UNLESS NOTED OTHERWISE. HOSE OR BUCKET DIRECTLY ONTO THE REINFORCEMENT.
ASSUMED LOADS. D. AT INTERIOR FACES OF GARAGE WALLS: 1"
7. SLUMP LIMITS APPLY AT THE TRUCK AT THE TIME OF DISCHARGE EXCEPT THAT PUMPED CONCRETE SHALL BE AT EXTERIOR FACES OF GARAGE WALLS: 2" 20. ALL INSERTS AND SLEEVES SHALL BE CAST-IN-PLACE WHEREVER POSSIBLE. DRILLED AND POWDER-DRIVEN
8. DESIGN WIND LOADING (ASCE 7, CHAPTER 6): SAMPLED AT THE DISCHARGE END OF THE HOSE. WHEN A SUPERPLASTICIZER IS USED, THE SLUMP SHALL BE FASTENERS WILL BE PERMITTED ONLY WHEN IT CAN BE SHOWN THAT THE INSERTS WILL NOT SPALL THE
WIND DESIGN OPTION METHOD 2 - ANALYTICAL PROCEDURE MEASURED AT THE TRUCK BEFORE INTRODUCING THE SUPERPLASTICIZER. STRENGTH TESTS SHALL BE MADE F. FORMED SURFACES OF SLABS: CONCRETE AND ARE LOCATED SO AS TO AVOID THE TENDONS AND ANCHORAGES. THE CONTRACTOR
BASIC WIND SPEED (3-SECOND GUST) ....................................................... 90 MPH ON CONCRETE AS PLACED WITH ALL ADDITIVES. INTERIOR EXPOSURE: 1" SHALL MARK TENDON LOCATIONS ON THE SURFACE OF THE SLAB IF DRILLING OR CORING IS TO BE DONE
WIND IMPORTANCE FACTOR ........................................................................ 1.15 #5 BAR AND SMALLER, EXPOSED TO WEATHER: 1 1/2" AFTER CONCRETE IS PLACED. 1 09/26/2013 ADDENDUM #2
OCCUPANCY CATEGORY .............................................................................III 8. FIBER-REINFORCED WORKSLAB SHALL BE REINFORCED WITH "FIBERMESH" POLYPROPYLENE FIBERS, MD #6 BAR AND LARGER, EXPOSED TO WEATHER: 2" NO. DATE DESCRIPTION
EXPOSURE CATEGORY................................................................................ B GRADED, WITH A MINIMUM OF 1.5 POUNDS OF FIBER PER CUBIC YARD. 21. CONDUITS UP TO 1" OUTSIDE DIAMETER MAY BE PLACED IN POST-TENSIONED SLABS PROVIDED THAT REVISIONS
INTERNAL PRESSURE COEFFICIENT, GCpi .................................................... +/-0.18 1 G. FORMED SURFACES OF BEAMS AND WIDE PAN JOISTS TENDONS ARE NOT DISPLACED AND THE CONDUITS ARE PLACED IN THE MIDDLE THIRD OF THE SLAB
COMPONENTS & CLADDING .......................................................................... 50 PSF 9. SHRINKAGE-COMPENSATING CONCRETE SHALL BE USED FOR LEVEL P1 POST-TENSIONED SLAB. SHRINKAGE- INTERIOR EXPOSURE: 1 1/2" THICKNESS. PARALLEL CONDUITS MUST BE AT LEAST 6" APART.
COMPENSATING CONCRETE MIX SHALL INCLUDE AN ADDITIVE EQUAL TO ECLIPSE 4500 SHRINKAGE REDUCING EXTERIOR EXPOSURE: 2"
9. SEISMIC DESIGN DATA (IBC, CHAPTER 16): ADMIXTURE BY GRACE CONCRETE PRODUCTS AT A RATE OF 2 GALLONS/CUBIC YARD.
SEISMIC IMPORTANCE FACTOR.................................................................. 1.25 H. TOP STEEL IN SLABS AND JOISTS:
OCCUPANCY CATEGORY .............................................................................III 10. LIGHTWEIGHT CONCRETE SHALL HAVE A MAXIMUM CURED DENSITY OF 120 POUNDS PER CUBIC FOOT. INTERIOR EXPOSURE: 1" NONCOMPOSITE TOPPING SLABS – LEVELS 1 THROUGH 6
MAPPED SPECTRAL RESPONSE ACCELERATOR, SS/S1 ............................. 0.11/0.03 EXPOSED TO WEATHER: 2"
SITE CLASS ...................................................................................................C 11. ANY PLACEMENT OF STRUCTURAL CONCRETE WITH A MINIMUM DIMENSION EQUAL TO OR GREATER THAN 5'-0" 1. ARCHITECTURAL TOPPING SLABS ON LEVELS 1 THRU 6 SHALL BE 6” THICK, EXCEPT WHERE WOOD, STONE OR
SPECTRAL RESPONSE COEFFICIENTS, SDS/SD1 ......................................... 0.10/0.04 OR AS NOTED IN THE DRAWINGS SHALL BE CONSIDERED MASS CONCRETE. MASS CONCRETE POURS SHALL I. TOP STEEL IN BEAMS: TERRAZZO FLOORING REQUIRES LESSER DEPTH. SEE ARCHITECTURAL DRAWINGS FOR FLOOR FINISHES AND
SEISMIC DESIGN CATEGORY ........................................................................ A COMPLY WITH THE FOLLOWING CONTROLS AND CHARACTERISTICS: INTERIOR EXPOSURE: 1 1/2" LOCATIONS & TOPPING THICKNESSES.
BASIC SEISMIC-FORCE-RESISTING SYSTEMS .............................................. SHEAR WALL-FRAME EXPOSED TO WEATHER: 2"
INTERACTIVE SYSTEM WITH A. MAXIMUM INTERNAL TEMPERATURE AFTER PLACEMENT OF 160 DEGREES F. 2. REINFORCE TOPPING SLABS WITH #3 AT 9” O.C., EACH WAY TOP IN 6” THICK TOPPING SLABS. PROVIDE #3 AT
ORDINARY REINFORCED B. MAXIMUM INTERNAL TEMPERATURE DIFFERENCE OF 35 DEGREES F. 12. GARAGE LEVEL FLOORS AND INSIDE FACES OF PARKING LEVEL WALLS SHALL NOT BE CONSIDERED TO BE 12” O.C., EACH WAY TOP IN SLABS 4 ½” OR LESS IN THICKNESS.
CONCRETE MOMENT FRAMES C. CLASS "F" FLY ASH AT 25 TO 50 PERCENT REPLACEMENT RATIO. EXPOSED TO RAIN. INTERIOR COVERS APPLY.
AND ORDINARY REINFORCED D. MAXIMUM RATIO OF WATER/CEMENTITIOUS MATERIALS OF 0.50. 3. BUILT-UP SLABS SHALL BE REINFORCED WITH #3 BARS AT 12" O.C. EACH WAY, CENTERED IN SLAB, AND
CONCRETE SHEAR WALLS E. REDUCE CEMENT CONTENT TO MINIMUM NEEDED FOR STRENGTH. 13. SEE "POST-TENSIONING REINFORCING" SECTION FOR COVER OVER TENDONS. SHALL BE SUPPORTED ON POLYSTYRENE INSULATION BOARD (60 PSI). BUILT-UP SLABS SHALL HAVE
SEISMIC RESPONSE COEFFICIENT, CS .......................................................... 0.012 F. SUPERPLASTICIZER. PERIMETER AND INTERIOR STUB WALLS AROUND AND BETWEEN THE 4' x 8' INSULATION BOARD BLOCKS. SEE
RESPONSE MODIFICATION FACTOR, R ......................................................... 4.5 G. LIMESTONE AGGREGATE, WELL GRADED. 14. MAINTAIN THE SPECIFIED COVER DIMENSION WITHIN A TOLERANCE OF PLUS OR MINUS 3/8" EXCEPT FOR SLABS- INFILL MATERIAL GENERAL NOTES FOR ADDITIONAL INFORMATION.
ANALYSIS PROCEDURE USED ...................................................................... EQUIVALENT LATERAL FORCE H. MAY SUBSTITUTE 56-DAY BREAKS FOR DETERMINING STRENGTH IF APPROVED BY ENGINEER. ON-GRADE AND SOIL-FORMED MEMBERS, WHERE 5/8" TOLERANCE IS PERMITTED. EXTRA COVER
WEAKENS THE MEMBER AND REDUCED COVER LEADS TO CORROSION. 4. LAP REINFORCING 30 BAR DIAMETERS AT SPLICES AND PROVIDE CONTINUOUS BAR CHAIRS TO MAINTAIN
10. GROUND SNOW LOADING (ASCE 7, CHAPTER 7): 12. REFER TO SPECIFICATIONS FOR ADDITIONAL MIX REQUIREMENTS. PROPER COVERAGE OF 1" BELOW THE TOP SURFACE.
GROUND SNOW LOAD ..................................................................................5 PSF 15. PROVIDE FOUNDATION DOWELS TO MATCH MASONRY WALL REINFORCEMENT. DOWELS SHALL EXTEND A KEY PLAN
MINIMUM OF 60 BAR DIAMETERS ABOVE AND 30 BAR DIAMETERS BELOW TOP OF FOUNDATION. 5. PROVIDE #3 X 4’-6” DIAGONAL TOP AND BOTTOM AT BLOCK-OUTS AND RE-ENTRANT CORNERS.
11. STACKS OF MATERIALS OR OTHER CONSTRUCTION LOADS PLACED ON THE STRUCTURE SHALL NOT EXCEED CRANE AND MAT SLAB FOUNDATIONS ALTERNATIVELY, DOWELS MAY BE EPOXY-GROUTED INTO THE FOUNDATION AFTER CONCRETE IS CAST, CITY OF AUSTIN
THE STATED DESIGN LIVE LOAD FOR THE AREA AFFECTED UNLESS ADEQUATELY SHORED. PROVIDED FULL DEVELOPMENT OF THE DOWEL IS ACHIEVED. REFER TO CMU BASE DETAIL(S) ON SHEET S200 6. THE BASE SLAB MUST HAVE A SMOOTH TROWELED FINISH. IF IT DOES NOT HAVE A SMOOTH SURFACE, THE
1. CRANE AND MAT SLAB FOUNDATIONS ARE DESIGNED BASED ON GEOTECHNICAL REPORT PREPARED BY FOR ADDITIONAL INFORMATION. BASE SLAB SHALL FIRST BE SMOOTHED WITH A SELF-LEVELING, HIGH-STRENGTH, NON-SHRINK GROUT, OR
JAMES G. BIERSCHWALE, P.E. OF TERRACON CONSULTANTS, INC., DATED 01-31-12 (PROJECT NO. 96115059), BY HAND TROWELING A HIGH-STRENGTH, NON-SHRINK REPAIR MORTAR. RECESSES IN THE BASE SLAB SHALL
"ADDITIONAL GEOTECHNICAL ENGINEERING SERVICES" PREPARED BY TODD E. SWOBODA, P.E., DATED 16. REFER TO ARCHITECTURAL SHEET A903 FOR CMU VERTICAL AND HORIZONTAL REINFORCING. BE TRANSITIONED WITH A HIGH-STRENGTH, NON-SHRINK HAND TROWELED REPAIR MORTAR TO LESS THAN A
05-13-13, "SUPPLEMENTAL GEOTECHNICAL RECOMMENDATIONS" PREPARED BY ANITHA MEDICHETTI, P.E., 30 DEGREE ANGLE. OWNER
DATED 07-15-13 AND "SUPPLEMENTAL GEOTECHNICAL RECOMMENDATIONS" PREPARED BY ANITHA
MEDICHETTI, P.E., DATED 08-08-13. 7. INSTALL TWO LAYERS OF 6-MIL POLY TO ACT AS A BOND BREAKER BETWEEN THE BASE SLAB AND NEW NEW CENTRAL LIBRARY
TOPPING SLAB. STAGGER JOINTS BETWEEN THE TWO LAYERS. LAP THE JOINTS IN THE BOTTOM LAYER 6
2. SLAB MIX AND PLACEMENT SHALL COMPLY WITH ALL MASS CONCRETE REQUIREMENTS. INCHES. TAPE THE JOINTS IN THE TOP POLY LAYER WITH MANUFACTURER’S RECOMMENDED JOINT TAPE. CIP ID#7235.001
3. TEMPERATURE OF CONCRETE SHALL BE CLOSELY MONITORED DURING CASTING OPERATIONS. PRECAUTIONS W. CESAR CHAVEZ BLVD.
8. IN EXPOSED TOPPING SLABS INSTALL CROSS JOINTS IN THE TOPPING IN EACH DIRECTION AT A MAXIMUM
SHALL BE TAKEN TO LIMIT TEMPERATURE DIFFERENTIAL OF THE CONCRETE FROM EXCEEDING 35 DEGREES SPACING OF 24 TIMES THE TOPPING THICKNESS OR 12 FEET MAXIMUM FOR 6” SLABS. JOINTS SHALL BE PROJECT
AUSTIN, TX
FAHRENHEIT AT ANY LOCATION. TOOLED OR SAWN, APPROXIMATELY 1 1/2" DEEP. SAWING SHALL BE MADE WITHIN 4 HOURS AFTER PLACING.
CUT ALTERNATE BARS DIRECTLY BENEATH CONTROL JOINTS TO CREATE WEAK PLANES IN THESE LOCATIONS.
4. THE CONCRETE SUPPLIER SHALL SUBMIT A THERMAL CONTROL PLAN ADDRESSING MAXIMUM AIR
TEMPERATURE, THE NEED FOR INSULATING BLANKETS AND PRECOOLED MATERIALS, AND PROCESS FOR 9. FOR THINNER TOPPING SLABS SUPPORTING HARD FINISHES SUCH AS STONE OR TERRAZZO PROVIDE JOINTS AT
INTERNAL TEMPERATURE MEASUREMENT. A MAXIMUM SPACING OF 24 TIMES THE TOPPING THICKNESS WITH TOOLED OR SAWN JOINTS APPROXIMATELY GENERAL NOTES
T/4 DEEP.
5. AFTER EXCAVATION OPERATIONS, PLACE 4" THICK MUD SLAB TO PROTECT EXCAVATION. LAY DRAWING TITLE
WATERPROOFING AND COVER WITH 4" THICK FIBER-REINFORCED WORK SLAB.
CIP ID#7235.001

10. JOINT PATTERN SHALL BE COORDINATED WITH COLUMNS, OFFSETS, POUR JOINTS AND OTHER DISCONTINUITIES
TO PRODUCE APPROXIMATELY RECTANGULAR SECTIONS WITH LENGTH NOT EXCEEDING 1.5 TIMES THE WIDTH.
6. IN ADDITION TO MAT SLAB REINFORCING SPECIFIED ON THE DRAWINGS, PROVIDE CONTINUOUS WWM 4x4 - JOINTS IN THE TOPPING ARE TO ALIGN WITH JOINTS IN THE TERRAZZO, STONE OR OTHER HARD FINISHES.
W2.9xW2.9 TOP TO PROVIDE WALKING SURFACE DURING CONSTRUCTION.
11. WHERE THE TOPPING SLAB IS TO BE POURED AROUND COLUMNS OR OTHER ELEMENTS PENETRATING THROUGH
7. MAT SLAB SHALL BE TOPPED WITH TWO LAYERS OF 6 MIL POLY TO SEPARATE MAT CONCRETE FROM THE TOPPING SLAB, PROVIDE A COMPRESSIBLE FILLER MATERIAL SUCH AS “DECK-O-FOAM” OR “CERAMAR”
TOPPING CONCRETE TO MINIMIZE CRACKING AS TOPPING SLAB UNDERGOES SHRINKAGE AND CREEP. AROUND COLUMNS, COLUMN BLOCKOUTS AND OTHER PROTRUSIONS.

8. AFTER PLACEMENT OF POLY SLIP LAYER, PROVIDE REINFORCED CONCRETE TOPPING SLOPED TO FLOOR 12. TOPPING SLAB SHALL BE MOIST CURED USING CURING BLANKETS OR PLASTIC COVERED MAT. DO NOT APPLY
DRAINS AS DETAILED ON THE PLANS. PLASTIC SHEET DIRECTLY TO SLABS THAT WILL BE PERMANENTLY EXPOSED AS THIS CAUSES STAINING.
PROVIDE CURING FOR 7 DAYS MINIMUM.

13. THE TOPPING MIX SHALL HAVE THE FOLLOWING PROPERTIES:


SLUMP (BEFORE ADMIXTURES) ............................ 3” to 5" SCALE
1/8" = 1'-0" DATE
08/16/13
WATER CEMENT RATIO ......................................... 0.45
28 DAY DESIGN STRENGTH .................................. 3500 PSI 3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER
MAXIMUM AGGREGATE SIZE ................................ 1"
NO AIR ENTRAINMENT Author Checker
DRAWN CHECKED
SHRINKAGE REDUCING ADMIXTURE OPTIONAL
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS


14. THE COARSE AGGREGATE SHALL BE NORMAL WEIGHT, WELL GRADED CRUSHED LIMESTONE. AGGREGATES
SHALL COMPLY WITH THE FOLLOWING:

A. COARSENESS FACTOR: THE COARSENESS FACTOR AS CALCULATED IN ACI 302-04, SECTION


6.3.2, SUBSECTION 2 SHALL BE BETWEEN 50 AND 70 PERCENT.
S002
9/26/2013 8:29:53 AM

B. WORKABILITY FACTOR: THE ADJUSTED WORKABILITY FACTOR AS CALCULATED IN ACI 302-04,


SECTION 6.3.2, SUBSECTION 2 SHALL BE NOT LESS THAN 2 PERCENT NOR MORE THAN 7
PERCENT ABOVE THE TREND BAR SHOWN IN ACI 302-04 FIGURE 6.1.
DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
CONCRETE FINISHES POST-TENSIONING REINFORCING STRUCTURAL STEEL - CONTINUED STAINLESS STEEL CABLES AND CABLE COMPONENTS

1. FORMWORK FINISH OPTIONS: 1. FOR SLABS POST-TENSIONING STRAND SHALL BE 0.5" OR 0.6" DIAMETER 7 WIRE, LOW RELAXATION 4. STRUCTURAL STEEL MATERIAL SHALL CONFORM TO THE FOLLOWING DESIGNATIONS: 1. CABLES AND CABLE COMPONENTS SHALL BE SUPPLIED BY ONE OF THE FOLLOWING:
STRAND, WITH A YIELD STRENGTH OF 270 KSI. TENDONS SHALL BE UNBONDED; GREASED AND A. TRIPYRAMID STRUCTURES, INC., WESTFORD, MA.
OFFSETS IN SHEATHED IN PLASTIC. WIDE FLANGE (W) SHAPES AND TEES A 992 (50 KSI YIELD) B. JAKOB AG, DORSTRASSE 34, CH03555 TRUBSCHACHEN, SWITZERLAND.
FORMED SURFACES OTHER ROLLED SHAPES, PLATES AND RODS A 36 (36 KSI YIELD) C. PFEIFER CABLE STRUCTURES, MEMMINGEN, GERMANY.
CLASS ABRUPT OR GRADUAL USAGE 2. ADD ADDITIONAL TENDONS IN ONE WAY SLABS PERPENDICULAR TO THE MAIN TENDONS, IN HOLLOW STRUCTURAL SHAPES (HSS OR TS) A 500, GRADE B (42 KSI YIELD ROUND / D. APPROVED EQUAL.
ORDER TO MAINTAIN UNIFORM COMPRESSION STRESS OF 175 PSI. 46 KSI YIELD SQUARE)
A 1/8" CLASS A EXPOSED SURFACES AS DEFINED ON ARCHITECTURAL PIPE A 53, GRADE B (35 KSI YIELD) 2. THE CABLE MANUFACTURER SHALL HAVE 10 YEARS MINIMUM EXPERIENCE AND HAVE SUCCESSFULLY
DRAWINGS. 3. ALL TEARS IN SHEATHING SHALL BE REPAIRED IN ACCORDANCE WITH MANUFACTURER'S BOLTS FOR CONNECTIONS A 325N COMPLETED 7 PROJECTS OF SIMILAR SIZE AND SCOPE.
RECOMMENDATIONS. ANCHOR BOLTS (ANCHOR RODS) F 1554 (36 KSI YIELD)
B 1/4" GENERAL STANDARD FOR PERMANENTLY EXPOSED SURFACES. 3. THE CABLE DETAILER AND INSTALLER SHALL HAVE 7 YEARS MINIMUM EXPERIENCE AND HAVE
4. SLIGHT DEVIATIONS IN THE SPACING OF THE SLAB TENDONS WILL BE PERMITTED, WHERE REQUIRED, 5. PREDESIGNED BEAM CONNECTION DETAILS ARE SHOWN ON SHEET S602. OTHER TYPICAL SUCCESSFULLY COMPLETED 5 PROJECTS OF SIMILAR SIZE AND SCOPE.
C 1/2" EXPOSED SURFACES IN GENERALLY UNFINISHED SPACES. TO AVOID OPENINGS, INSERTS AND DOWELS WHICH ARE SPECIFICALLY LOCATED. WHERE CONNECTIONS ARE SHOWN IN TYPICAL DETAILS. CONNECTIONS WHICH ARE NOT SPECIFICALLY
LOCATIONS OF TENDONS INTERFERE WITH EACH OTHER, CONTACT THE STRUCTURAL ENGINEER DETAILED SHALL BE DESIGNED BY THE FABRICATOR IN ACCORDANCE WITH THE CONNECTION NOTES 4. DAMAGED OR DEFECTIVE CABLES AND/OR COMPONENTS SHALL BE REMOVED AND REPLACED AT NO
D 1" SURFACES PERMANENTLY CONCEALED, SO BEFORE MOVING ANY TENDONS. TENDONS SHALL CLEAR OPENINGS BY AT LEAST 6" AND SHALL AND SPECIFICATIONS. COST TO THE OWNER.
ROUGHNESS IS NOT OBJECTIONABLE. HAVE A MAXIMUM SKEW OF ONE TO SIX ENDING NO CLOSER THAN 1'-0" FROM OPENING EDGE.
6. ALL MOMENT CONNECTIONS SHALL BE FULLY WELDED CONNECTIONS DESIGNED TO DEVELOP THE FULL 5. CABLE HANDLING, CONNECTION DETAILS, AND COMPONENT INSTALLATION SHALL COMPLY WITH THE
E - BOARD FORMED FINISHES 5. SHOP DRAWINGS SHALL SHOW SEQUENCE OF PLACING POST-TENSIONING TENDONS AT COLUMNS CROSS-SECTION OF THE MEMBER. STIFFENER PLATES, WHERE SHOWN, ARE MANDATORY AND MAY CABLE SUPPLIER’S RECOMMENDATIONS AND ASCE 19-96. WHERE REQUIREMENTS DIFFER, THE MORE
(WEAVING OF PERPENDICULAR STRANDS AS REQUIRED TO MAINTAIN PROPER DRAPE). NOT BE OMITTED. MOMENT CONNECTIONS ARE INDICATED ON THE PLANS BY A TRIANGULAR BULB ON STRINGENT SHALL GOVERN.
THE END OF THE BEAM, OR BY THE LETTERS "MC".
6. PLACE TWO CONTINUOUS NO. 4 BARS BEHIND UNIFORMLY SPACED ANCHORS AT EDGE OF SLAB. 6. ALL CABLES, CABLE ATTACHMENTS, AND PINS SHALL BE “ARCHITECTURAL GRADE” POLISHED STAINLESS
Lake|Flato
2. VERTICAL SURFACE LOCATIONS: 7. CANTILEVER BEAMS MOMENT CONNECTED TO THE FRAME SHALL BE THE SAME SIZE AS THE BACK-UP STEEL.
311 Third Street, San Antonio , Texas 78205
7. UNIFORM SLAB TENDONS SHALL BE STRESSED BEFORE BEAM TENDONS OR BANDED SLAB TENDONS. SPAN IF NO SIZE IS GIVEN. T:210.227.3335
BUILDING INTERIOR: 7. CABLE ATTACHMENTS, CONNECTORS, ETC. SHALL HAVE A MINIMUM TENSILE STRENGTH EQUAL TO 90 www.LakeFlato.com
EXPOSED INTERIOR ROUND BUILDING COLUMNS IN ATRIUM ......... CLASS A 8. MINIMUM CONCRETE COVER OVER TENDONS SHALL BE AS FOLLOWS: 8. ALL BOLTS IN BEAM, GIRDER, COLUMN AND BRACE CONNECTIONS SHALL BE FULLY TENSIONED. ALL PERCENT OF THE CABLE BREAKING STRENGTH.
(FORM LINER IS ALT. NO. 10) OTHER BOLTS MAY BE TIGHTENED TO ONLY A "SNUG TIGHT" CONDITION. Shepley Bulfinch Richardson & Abbott
EXPOSED INTERIOR ROUND BUILDING COLUMNS NOT IN ATRIUM ..CLASS B INTERIOR SLAB SPANS: 3/4" 8. COMPONENT SUBSTITUTIONS SHALL HAVE SIZES EQUAL TO OR LARGER THAN THOSE SPECIFIED ON THE 2 Seaport Lane, Boston, Massachusetts 02210
EXPOSED EXTERIOR SQUARE BUILDING COLUMNS ....................... CLASS B SLAB END SPANS AND CANTILEVERS: 1 1/2" 9. BACK TO BACK CHANNELS OR DOUBLE ANGLES ACTING AS COMPRESSION MEMBERS SHALL BE STRUCTURAL DRAWINGS AND DETAILS. T:617.423.1700
CONNECTED TO EACH OTHER AT THIRD POINTS ALONG THE LENGTH BY WELDING IN SPACER PLATES OF www.ShepleyBulfinch.com
(EXPOSED CORNERS TO INTERIOR BEAM OR JOIST SPANS: 1 1/2"
HAVE EASED EDGES) BEAM OR JOIST END SPANS AND CANTILEVERS:
2" EQUAL THICKNESS TO THE GUSSET PLATES. UNEQUAL LEG ANGLES SHALL BE ORIENTED LONG LEG 9. CABLES SHALL BE SEQUENTIALLY STRESSED TO A FINAL STRESS OF 8.4 KSI AT AN INSTALLATION
NON-EXPOSED BUILDING COLUMNS .............................................. CLASS B DOWN UNLESS NOTED OTHERWISE. TEMPERATURE OF 95 DEGREES F. THE CABLE STRESS SHALL BE INCREASED FOR COOLER INSTALLATION
INTERIOR ELEVATOR WALLS .........................................................CLASS B FOR PARKING LEVELS: TEMPERATURES AND DECREASED FOR WARMER INSTALLATION TEMPERATURES.
SHEAR WALLS AT STAIRS ............................................................. CLASS B SLAB SPANS TOP: 1 1/2" 10. TEMPORARY CONSTRUCTION BRACING OF STRUCTURAL STEEL FRAME SHALL REMAIN IN PLACE UNTIL
CONCRETE STAIRS IN BUILDING-SIDES & SOFFITS ........................ CLASS B SLAB SPANS BOTTOM: 3/4" AFTER ALL PERMANENT BRACING COMPONENTS HAVE BEEN COMPLETED. THE LATERAL-LOAD- 10. THE GENERAL CONTRACTOR SHALL COORDINATE CONNECTOR HOLE LOCATIONS, CONNECTOR PIN HOLE
ELECTRICAL & TRANSFORMER VAULT WALLS & CEILING ............ CLASS D BEAM SPANS: 1 1/2" RESISTING SYSTEM OFTHE BUILDING INCLUDES MOMENT-CONNECTED RIGID FRAMES, DESIGNATED WIND DIAMETERS, ETC. BETWEEN CABLE SUPPLIER AND STRUCTURAL STEEL SUPPLIER. WHERE THE CABLE
LEVEL 2 THRU 6 FLOOR SOFFITS ..................................................CLASS D TYPICAL U.N.O. BRACES, CONCRETE SHEAR WALLS AND CONNECTING DIAPHRAGM ELEMENTS. THE METAL ROOF DECK SUPPLIER’S TOLERANCES EXCEED AISC, THE MORE STRINGENT SHALL GOVERN.
LEVEL 2 THRU 6 ATRIUM EDGE BEAM 9. MINIMUM CONCRETE COVER OVER ANCHORAGE ASSEMBLY SHALL BE 1 1/2". IS AN ESSENTIAL DIAPHRAGM COMPONENT OF THE PERMANENT BRACING SYSTEM.
VERTICAL & HORIZONTAL SURFACES TO CEILING ....................... CLASS A PROJECT CONSULTANT

(EXPOSED CORNERS TO 10. FOR POST-TENSIONED SLABS, TENDONS SHALL BE STRESSED IN TWO STAGES. STRESS TENDONS AT 11. WIND BRACES IN THE VERTICAL PLANE ARE DENOTED BY "WB" ON THE PLAN. SEE WIND BRACE DETAILS ELEVATOR FRAMING
HAVE EASED EDGES) FIRST STAGE TO A LEVEL OF 0.33 Fpu BETWEEN 24 AND 36 HOURS AFTER POURING CONCRETE. 1 FOR CONFIGURATIONS.
TRANSFER GIRDERS BELOW LEVEL 3 ........................................... CLASS B CONCRETE STRENGTH AT FIRST STAGE OF STRESSING SHALL BE 1500 PSI, MINIMUM. DO NOT STRESS 1. STRUCTURAL BEAMS SUPPORTING THE ELEVATOR BEAMS ARE SHOWN FOR KONE ECOSPACE
TENDONS IN SECOND STAGE UNTIL RESULTS OF TEST CYLINDERS INDICATE THAT A CONCRETE 12. SHELF ANGLES SHOWN AS CONTINUOUS IN THE SECTIONS SHALL BE INSTALLED IN 20'-0" MAXIMUM ELEVATORS. IF AN ELEVATOR OF ANOTHER MODEL OR MANUFACTURER IS USED, SUPPORTING BEAMS
GARAGE: STRENGTH EQUAL TO 75 PERCENT OF THE DESIGN COMPRESSION STRENGTH HAS BEEN ATTAINED. LENGTHS, LEAVING A 1/4" GAP BETWEEN ENDS AND AT CORNERS. LOCATE GAPS TO MATCH MASONRY DESIGN SHALL BE VERIFIED BY THE CONTRACTOR.
GARAGE WALLS ............................................................................. CLASS C CONTROL JOINTS.AT BUILDING EXPANSION JOINT, LEAVE A GAP TO MATCH EXPANSION JOINT WIDTH.
GARAGE COLUMNS ........................................................................CLASS C 11. FOR POST-TENSIONED BEAMS, JOISTS AND TRANSFER GIRDERS, DO NOT BEGIN STRESSING TENDONS 2. WHERE FLOOR-TO-FLOOR HEIGHT IS GREATER THAN THE DISTANCE ALLOWED FOR STANDARD ELEVATOR PROJECT CONSULTANT

GARAGE LEVEL P1 AND LEVEL 1 SOFFIT .....................................CLASS C UNTIL RESULTS OF TEST CYLINDERS INDICATE THAT A STRENGTH EQUAL TO 75 PERCENT OF THE 13. CONNECT MISCELLANEOUS STEEL MEMBERS USING FILLET WELDS SUFFICIENT TO DEVELOP THE TENSILE GUIDE RAIL SPANS, ELEVATOR SUPPLIER SHALL FURNISH HEAVIER RAILS OR REINFORCED RAILS DESIGNED
GRAPHICS WALL AT SW ENTRY ................................................... CLASS B DESIGN STRENGTH HAS BEEN ACHIEVED. STRENGTH OF THE SMALLER MEMBER AT THE JOINT UNLESS SHOWN OTHERWISE. TO SPAN FROM FLOOR-TO-FLOOR WITHOUT INTERMEDIATE STRUCTURAL SUPPORT.
FACES OF P1 AND L1 EDGE BEAMS AT EAST & SW ENTRIES ...... CLASS B
GARAGE CONCRETE STAIR SIDES & SOFFITS ............................... CLASS B 12. FOR MULTI-STRAND BONDED SYSTEM: 14. ALL STEEL SHALL BE FURNISHED WITH SHOP COAT OF RUST INHIBITIVE PRIMER.
PLANTER WALLS EXPOSED ...........................................................CLASS E METAL ROOF DECK OF T
PLANTER WALLS UNEXPOSED .......................................................CLASS D A. POST-TENSIONING TENDONS SHALL BE MULTI-STRAND BONDED (GROUTED) TENDONS, 15. WHERE ANGLES ARE NOTED TO BE CONTINUOUS, PROVIDE FULL BUTT WELD AT SPLICES. TE EX
A A
1. ROOF DECK SHALL BE 3" DEEP, 18 GAUGE, WIDE RIB, METAL DECK, WITH 8" RIB SPACING, MEETING THE

T
CONSISTING OF MULTIPLE 270 KSI STRANDS, ENCLOSED IN FLEXIBLE METAL CONDUIT.

S
16. ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) NOTED ON THE DRAWINGS OR IN THIS REQUIREMENTS OF THE STEEL DECK INSTITUTE. DECK SHALL BE SHOP PAINTED WITH ONE COAT OF
3. HORIZONTAL SURFACE LOCATIONS: B. TENDONS SHALL BE INSERTED INTO CONDUIT BEFORE POURING CONCRETE. SCHEDULE AS AESS SHALL COMPLY WITH THE TOLERANCES (MILL, FABRICATION AND ERECTION) FACTORY BAKED ON PRIMER PAINT.
SPECIFIED. FINISHING REQUIREMENTS FOR AESS VARY BY CATEGORY, AS SCHEDULED BELOW: JOELLE S. ROSENTSWIEG
TYPICAL INTERIOR FLOOR SLAB ...................................................HARD TROWELLED FINISH C. TENDONS SHALL CLEAR BLOCK-OUTS AND SLEEVES BY AT LEAST 6". WHEN CONFLICTS 2. ROOF DECK SHALL BE CONTINUOUS OVER TWO OR MORE SPANS.

R
PR
89451
PLAZA SLAB ................................................................................... HARD TROWELLED FINISH OCCUR BETWEEN DETAILED TENDON LOCATION AND SLEEVES, BLOCK-OUTS OR OTHER

E
E
3. TYPICAL DECK CONNECTIONS SHALL BE AS FOLLOWS: L

O
ELECTRICAL & TRANSFORMER VAULT FLOORS ........................... HARD TROWELLED FINISH REINFORCEMENT, CONTACT THE STRUCTURAL ENGINEER BEFORE MOVING ANY TENDONS. IC
ENSE
D

N
F
E
TREADS FOR ALL CONCRETE STAIRS ...........................................LIGHT BROOM FINISH AT EACH SUPPORT: PUDDLE WELDS AT EACH SIDE LAP AND AT INTERMEDIATE RIBS NOT TO S
S N
G
ONAL E
GARAGE MAT SLAB ....................................................................... RAKED FINISH D. CONCRETE IN THE ANCHORAGE ZONE, DEFINED AS A CYLINDER WITH 12 INCH RADIUS AND EXCEED 8" O.C. SPACING.
AT SIDE LAPS: PUDDLE WELDS AT 12" O.C. SPACING BETWEEN SUPPORTS.
GARAGE MAT SLAB TOPPING AND P-T SLAB ...............................LIGHT BROOM FINISH
GARAGE RAMP SLAB ..................................................................... RAKED FINISH,
18 INCH LENGTH BEHIND THE ANCHOR SHALL NOT CONTAIN CONDUIT, JUNCTION BOXES,
SLEEVES OR OTHER VOID-FORMING DEVICES. AESS FINISHING AT EXTERIOR SIDES, PARALLEL TO DECK SPAN: PUDDLE WELDS AT 8" O.C. SPACING.
PERPENDICULAR TO SLOPE
CATEGORY REQUIRED NOT REQUIRED LOCATION OF APPLICATION 4. SCREWS SHALL BE "TEKS" #12-14X3/4" HWH #2.
E. END ANCHORAGE ASSEMBLIES SHALL BE PLACED PERPENDICULAR TO TENDON DRAPE AND
SHALL BE RECESSED TO PROVIDE 1" CLEAR CONCRETE COVER AT ENDS. 1 WELDS GROUND SMOOTH READING PORCH
4. SEE ARCHITECTURAL FOR ANY FINISHES NOT LISTED HERE. 5. PUDDLE WELDS SHALL BE FULL-FUSION, 3/4" DIAMETER (MINIMUM) WELDS, MADE THROUGH WELD
WELDS CONTOURED AND BLENDED CANOPY AT NORTH ENTRY WASHERS. METAL AROUND WELDS SHALL BE COMPLETELY INTACT AFTER WELDING.
F. AFTER FINAL STRESSING RECORDS HAVE BEEN APPROVED, PUMP GROUT THROUGH CANOPY AT EAST ENTRY
5. SEE ARCHITECTURAL FOR ORIENTATION OF ROUND COLUMN FORM JOINTS AND ATRIUM BEAM FORM JOINT LOCATIONS. CONDUIT, CUT OFF EXCESS STRAND, AND FILL ANCHORAGE RECESS WITH GROUT. CONTINUOUS WELDS
CANOPY AT SOUTH ENTRY 6. THE METAL ROOF DECK ON THIS PROJECT IS REQUIRED TO PERFORM AS A STRUCTURAL DIAPHRAGM, WITH
WELDS SHOW THROUGH MINIMIZED CURTAINWALL BACKUP
G. TENDONS SHALL BE STRESSED IN STAGES AS THE DEAD LOAD IS APPLIED, AS FOLLOWS: SHEAR LOADS OF 750 POUNDS PER FOOT. ALL WELDS AND SCREWS ARE CRITICAL TO THE SUCCESSFUL
COPING AND BLOCKING LEVEL 4 ATRIUM
STEEL FINISHES PERFORMANCE OF THE DIAPHRAGM.
TOLERANCES MINIMIZED GLASS BRIDGE 1
1) MINIMUM CONCRETE COVER OVER CONDUIT SHALL BE 2", UNLESS OTHERWISE ALL ATRIUM STAIRS
1. STEEL FINISH OPTIONS: DETAILED. JOINT GAP TOLERANCES 7. SUSPENDED CEILING, LIGHT FIXTURES, DUCTS OR OTHER UTILITIES SHALL NOT BE SUPPORTED BY THE
1 SCRIM
A. STANDARD SHOP PRIME, FIELD PAINT INTERIOR MINIMIZED STEEL DECK.
WEST CANOPY HANGERS
B. EPOXY SHOP PRINT FOR FIELD PAINT OF EXTERIOR-EXPOSED TO SUNLIGHT 2) SHOP DRAWINGS SHALL SHOW SEQUENCE OF STRESSING STRANDS WITHIN A PIECE MARKS HIDDEN
C. INTUMESCENT PAINT IN SHOP, TOUCH UP IN FIELD TENDON AND TENDONS WITHIN A MEMBER. BEAM SHALL BE STRESSED BEFORE
D. INTUMESCENT PAINT IN FIELD, TOUCH UP AFTER ERECTION SUPPORTING GIRDERS ARE STRESSED. SEAMS REMOVED WATERPROOFING
E. SHOP GALVANIZED, FIELD TOUCH-UP MILL MARKS REMOVED
F. SPRAY-ON FIREPROOFING 3) PROVIDE BEARING PLATES AT ALL DEAD END ANCHORS. DO NOT USE SPLAYED GRINDING OF SHEARED EDGES 1. SEE ARCHITECTURAL DRAWINGS FOR CONTINUOUS BLINDSIDE WATERPROOFING BEHIND BASEMENT
G. STANDARD SHOP PRIME, EPOXY PAINT IN SHOP, TOUCH UP IN FIELD WIRES FOR ANCHORAGE. WALLS AND BELOW MAT SLAB FOUNDATION.
SEAL WELDS TO CLOSE OPEN GAPS
H. SHOP GALVANIZED, PAINT IN FIELD
I. SHOP-PRIMED FOR FIELD-APPLIED PAINT 13. TENDON FORCES SHOWN ON THE DRAWINGS ARE EFFECTIVE FORCES AFTER ALL IMMEDIATE AND BOLT HEAD ORIENTATION DICTATED 2. WHERE APPLICABLE, VERIFY REBAR CHAIRS IN CONTACT WITH WATERPROOFING MEMBRANE ARE
J. STAINLESS LONG TERM LOSSES. THE LOSS OF STRESS IN POST- TENSIONED PRESTRESSING STEEL, DUE TO FIELD WELDING AIDS REMOVED COMPATIBLE WITH AND WILL NOT PUNCTURE OR DAMAGE THE WATERPROOFING SYSTEM. SEE
K. UNPAINTED CREEP AND SHRINKAGE OF CONCRETE, STEEL RELAXATION, FRICTION, CURVATURE, SWEEP CLOSE WELD ACCESS HOLES AT STRUCTURAL SPECIFICATIONS FOR ADDITIONAL CHAIR INFORMATION.
AROUND OPENINGS, ETC., SHALL BE CALCULATED BY SUPPLIER AND COMPENSATED FOR IN THE FULL PENETRATION WELDS
NUMBER OF TENDONS OR STRANDS PROVIDED. BURSTING REINFORCEMENT REQUIRED TO RESIST 3. ONCE REBAR AND PLUMBING INSTALLATION IS COMPLETE, WATERPROOFING CONSULTANT SHALL
2. LOCATIONS: BURSTING, SPLITTING AND SPALLING FORCES INDUCED BY TENDON ANCHORAGES SHALL BE CAREFULLY REVIEW WATERPROOFING AND REPAIR ANY DAMAGED AREAS JUST PRIOR TO CASTING MAT
DESIGNED AND FURNISHED BY THE POST-TENSIONING SUPPLIER. SUBMIT DESIGN CALCULATIONS 2 WELDS GROUND SMOOTH CONTINUOUS WELDS LOW STEEL ROOF OVER SLAB CONCRETE.
EXPOSED ROOF BEAMS OVER LEVEL 6.........................................C SEALED BY A REGISTERED PROFESSIONAL ENGINEER AND SHOP DRAWINGS CLEARLY DEPICTING WELDS CONTOURED AND BLENDED WELD SHOW THROUGH MINIMIZED LEVEL 6
CONCEALED ROOF BEAMS OVER LEVEL 6...................................F PROPOSED TENDON LAYOUT. PIECE MARKS HIDDEN COPING AND BLOCKING
LEVEL 6 STEEL COLUMNS...............................................................C WOOD FLOOR DECKING AND SHEATHING 1
SEAMS ORIENTED AWAY FROM VIEW TOLERANCES MINIMIZED
HIGH ROOF TRUSSES AND FRAMING.............................................F 14. UNLESS OTHERWISE INDICATED, THE EFFECTIVE FORCE SHALL APPLY AT THE POINT ALONG THE
MECHANICAL MEZZANINE FLOOR BEAMS.....................................F TENDON CALCULATED TO HAVE THE LEAST FORCE (GREATEST CUMULATIVE LOSSES). FORCE BOLT HEAD ORIENTATION DICTATED SEAMS REMOVED 1. WOOD FLOOR DECKING, WOOD FLOOR SHEATHING, AND THEIR CONNECTIONS SHALL COMPLY WITH
1 09/26/2013 ADDENDUM #2
READING PORCH FLOOR & ROOF FRAMING.................................. H AVERAGING IS NOT PERMITTED. FIELD WELDING AIDS REMOVED JOINT GAP TOLERANCES MINIMIZED CHAPTER 23 OF THE 2009 INTERNATIONAL BUILDING CODE.
NO. DATE DESCRIPTION
READING PORCH COLUMNS............................................................H CLOSE WELD ACCESS HOLES AT MILL MARKS REMOVED REVISIONS
ATRIUM STEEL/WOOD BRIDGE.......................................................C 15. TENDONS SHALL BE SECURED TO A SUFFICIENT NUMBER OF POSITIONING DEVICES TO ENSURE 2. UNLESS NOTED OTHERWISE ON PLAN, TONGUE AND GROOVE DECKING SHALL BE 2X DECKING (1 ½”
FULL PENETRATION WELDS GRINDING OF SHEARED EDGES INCHES DEEP). SEE ARCHITECTURAL DRAWINGS FOR THE DECKING LAY-UP PATTERN.
ATRIUM STEEL/GLASS BRIDGE......................................................C CORRECT LOCATION DURING AND AFTER THE PLACING OF CONCRETE, AND SHALL BE SUPPORTED
ATRIUM STAIRS................................................................................C AT A MAXIMUM OF 4'-0" ON CENTER. TWISTING OR ENTWINING OF INDIVIDUAL TENDONS WITHIN A SEAL WELDS TO CLOSE OPEN GAPS
OTHER STEEL STAIRS......................................................................I BUNDLE SHALL NOT BE PERMITTED. 3. DECKING MODULUS OF ELASTICITY MUST BE EQUAL TO OR GREATER THAN 1,700,000 PSI. DECKING
SCRIM SUPPORT FRAMING..............................................................H ALLOWABLE BENDING STRESS MUST BE EQUAL TO OR GREATER THAN 1,300 PSI.
3 PIECE MARKS HIDDEN WELDS GROUND SMOOTH
EXTERIOR CANOPY FRAMING.........................................................H 16. TENDONS SHALL CONFORM TO THE CONTROL POINTS SHOWN ON THE DRAWINGS AND SHALL
INTERIOR RAILINGS.........................................................................I HAVE A PARABOLIC DRAPE UNLESS NOTED OTHERWISE. PROFILE DIMENSIONS LOCATE THE SEAMS ORIENTED AWAY WELDS CONTOURED AND BLENDED 4. FASTEN WOOD NAILERS, WHERE DETAILED, TO STEEL SUPPORTS WITH 5/8 INCH DIAMETER THREADED
EXTERIOR RAILINGS........................................................................J CENTER OF GRAVITY OF TENDON STEEL OR TENDON GROUP (C.G.S.) MEASURED FROM THE FROM VIEW RODS FUSION WELDED TO THE BEAMS AT 1’-6” ON CENTER UNLESS NOTED OTHERWISE ON THE
CONTINUOUS WELDS
PV CANOPY BEAMS AND COLUMNS...............................................H MEMBER SOFFIT. LOW POINTS ARE AT MIDSPAN, UNLESS OTHERWISE SHOWN OR NOTED. DRAWINGS.
WELD SHOW THROUGH MINIMIZED
MASONRY SHELF ANGLES..............................................................E
EXPOSED HORIZONTAL BRACES AT SKYLIGHT ............................C 17. STRESSING OPERATION SHALL BE OBSERVED BY THE TESTING LABORATORY. A RECORD OF ALL COPING AND BLOCKING TOLERANCES ATRIUM SKYLIGHT 5. WHERE DECKING IS FASTENED DIRECTLY TO THE SUPPORTING STEEL, PROVIDE WOOD SCREWS THRU
STRESSING FORCES AND FIELD MEASURED ELONGATIONS SHALL BE SUBMITTED TO THE MINIMIZED NORTH LIGHT MONITOR PRE-DRILLED FLANGE HOLES TO THE DECKING. SEE DETAILS FOR SCREW SIZE & SPACING. SCREW
3. NOTE: IF A FINISH IS NOT DEFINED IN THIS SCHEDULE, VERIFY FINISH IN QUESTION WITH ARCHITECT. ARCHITECT WITHIN 48 HOURS. FIELD READINGS OF ELONGATIONS AND STRESSING FORCES SHALL SOUTH LIGHT MONITOR SPACING SHALL NOT EXCEED 6 INCHES.
JOINT GAP TOLERANCES MINIMIZED
NOT VARY BY MORE THAN 7 PERCENT FROM CALCULATED VALUES SHOWN ON THE SHOP DRAWINGS.
SEAMS REMOVED 6. UNLESS NOTED OTHERWISE, FASTEN 2X DECKING TO NAILERS WITH 10d NAILS AT 0’-6”.
4. FOR ARCHITECTURALLY EXPOSED STRUCTURAL STEEL, SEE FINISHING SCHEDULE IN STRUCTURAL STEEL
SECTION OF THESE GENERAL NOTES. 18. DO NOT CUT OFF TENDON ENDS UNTIL ALL TENDONS IN A GIVEN BAY HAVE BEEN SATISFACTORILY MILL MARKS REMOVED
STRESSED AND THE ELONGATION RECORDS APPROVED. AVOID OVERHEATING ANCHORS WHEN GRIND OF SHEARED EDGES 7. FASTEN ½” STRUCTURAL I PLYWOOD SHEATHING TO DECKING WITH 6d NAILS AT 0’-6” ON CENTER
CUTTING TENDONS. FILL STRESSING POCKETS WITH SPECIFIED GROUT. FINISH TO MATCH AROUND THE PERIMETER AND AT 1’-0” IN BETWEEN.
SEAL WELDS TO CLOSE OPEN GAPS
FIELD DRILLED DOWELS AND ANCHOR RODS IN CONCRETE SURROUNDING CONCRETE AT EXPOSED SURFACES.
BOLT HEAD ORIENTATION DICTATED 8. FASTENERS (NAILS, SCREWS, BOLTS, ETC.) SHALL NOT BE EXPOSED TO VIEW.
1. FIELD DRILLED DOWELS AND ANCHOR RODS TO BE SET IN HARDENED CONCRETE SHALL BE ONE OF THE SYSTEMS 19. SEE TYPICAL POST-TENSIONING REINFORCING DETAILS FOR ADDITIONAL INFORMATION. FIELD WELDING AIDS REMOVED
LISTED HERE. INSTALLATION SHALL BE BY TRAINED TECHNICIANS. CLOSE WELD ACCESS HOLES AT FULL KEY PLAN
20. POST-TENSIONED SLAB DESIGN IS BASED ON WOBBLE COEFFICIENT OF 0.0014 AND CURVATURE PENETRATION WELDS
SET-XP EPOXY ANCHORING SYSTEM, SIMPSON STRONG-TIE CO., PLEASANTON, CA COEFFICIENT OF 0.07. VERIFY ASSUMED WOBBLE AND CURVATURE COEFFICIENTS DURING TENDON CITY OF AUSTIN
PE1000+ STANDARD SET ADHESIVE ANCHORING SYSTEM, POWERS FASTENERS, BREWSTER, NY STRESSING OPERATIONS.
HIT/HY150 MAX SD ADHESIVE ANCHORING SYSTEM, HILTI FASTENING SYSTEMS, TULSA, OK 4 NONE ALL APPEARANCE ITEMS ALL OTHER AREAS
HIT-RE500-SD ADHESIVE ANCHORING SYSTEM, HILTI FASTENING SYSTEMS, TULSA, OK

2. DOWELS AND THREADED RODS, OF THE SIZE, TYPE, AND EMBEDMENT SHOWN ON THE DRAWINGS, SHALL BE INSTALLED OWNER
IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND AS INDICATED ON THE DRAWINGS. A 1
IF AN AESS ELEMENT IS NOTED ON THE DRAWINGS, BUT NOT LISTED IN THIS SCHEDULE, THE FOLLOWING CATEGORIES
STRUCTURAL STEEL SHALL APPLY:
MANUFACTURER’S REPRESENTATIVE SHALL BE PRESENT DURING INITIAL INSTALLATION TO PROVIDE ONSITE TRAINING
OF INSTALLERS. CATEGORY1: HIGH PROFILE CONDITIONS THAT ARE WITHIN REACH TO TOUCH AND CAN BE VIEWED IN CLOSE PROXIMITY.
NEW CENTRAL LIBRARY
1. STEEL FABRICATOR AND ERECTOR SHALL INCLUDE IN BASE BID AN ALLOWANCE FOR UP TO 10 TONS OF
MISCELLANEOUS STRUCTURAL STEEL (PLATE, PIPE, TUBE, WIDE-FLANGE, ETC.) TO BE INSTALLED IN THE CATEGORY2: HIGH PROFILE CONDITIONS THAT ARE OUT OF REACH TO TOUCH BUT CAN BE VIEWED FROM A DISTANCE OF CIP ID#7235.001
3. ANCHORS SHALL BE INSTALLED PERPENDICULAR TO THE FACE OF THE CONCRETE, UNLESS OTHERWISE INDICATED ON FIELD AS DIRECTED BY THE ENGINEER. ALLOWANCE SHALL COVER ALL COSTS INCLUDING MATERIAL, 20'-0" OR LESS.
THE DRAWINGS. W. CESAR CHAVEZ BLVD.
DETAILING, FABRICATION, TRANSPORTATION AND ERECTION. ANY UNUSED PORTION OF ALLOWANCE CATEGORY3: HIGH PROFILE CONDITIONS THAT ARE OUT OF REACH TO TOUCH BUT CAN BE VIEWED ONLY FROM DISTANCES AUSTIN, TX
SHALL BE CREDITED TO THE OWNER AT A UNIT COST PER TON ESTABLISHED DURING BIDDING. EXCEEDING 20'-0" PROJECT
4. THE CONTRACTOR SHALL CREATE A TEMPLATE FOR EACH ANCHOR ROD GROUP PRIOR TO FABRICATING HOLES IN
CONNECTION PLATES. TEMPLATES SHALL BE MADE AFTER LOCATING EXISTING REINFORCING STEEL WITH A SENSOR. CATEGORY4: CONDITIONS THAT ARE NOT HIGH PROFILE, WHERE TOLERANCES FOR FIT-UP ARE IMPORTANT, BUT ARE NOT
2. COORDINATION OF THE ROOF STRUCTURE AND THE ARCHITECTURAL SECTIONS AND ELEVATIONS HIGHLY VISIBLE.
POSITION ANCHOR HOLES SO AS NOT TO CONFLICT WITH THE EXISTING REINFORCING. ANCHOR POSITIONS MAY BE IS CRITICAL TO PROPER STRUCTURAL STEEL FABRICATION. ELEVATIONS OF TOP OF STRUCTURAL
ADJUSTED IN THE FIELD A MAXIMUM OF 1 1/2" FROM THE DIMENSIONS SHOWN ON THE DETAILS, TO AVOID CONFLICT
WITH THE EXISTING REINFORCING STEEL.
STEEL ARE SHOWN ON THE ARCHITECTURAL PLANS AND SECTIONS. REFER TO THESE SECTIONS
AND DETAILS TO SET THE STEEL ELEVATIONS AND TO UNDERSTAND THE ARCHITECTURAL INTENT.
GENERAL NOTES
5. SUBMIT DRAWINGS OF TEMPLATES FOR ANCHOR ROD GROUPS SHOWING HOLE LOCATIONS PRIOR TO FABRICATION OF 3. TOLERANCE REQUIREMENTS - STRUCTURAL DRAWINGS INDICATE MISCELLANEOUS STEEL ELEMENTS DRAWING TITLE
CONNECTION PLATES.
CIP ID#7235.001

SUCH AS SHELF ANGLES, LINTELS, SUPPORT MEMBERS FOR CURTAIN WALLS OR MASONRY, AND EDGE
ANGLES FOR OPENINGS AND PERIMETER CONDITIONS WHICH ARE INTENDED TO SUPPORT OR BE
6. HOLES SHALL BE DRILLED WITH A HAMMER DRILL. CORED HOLES ARE NOT PERMITTED. DIAMETER OF HOLES DRILLED IN COORDINATED WITH MATERIALS FURNISHED BY OTHER TRADES. IT IS THE INTENT OF THESE DRAWINGS
THE CONCRETE SHALL BE THE SIZE RECOMMENDED BY THE MANUFACTURER FOR THE RESPECTIVE ANCHOR SIZE. THAT THESE ELEMENTS BE FIELD ATTACHED BY FIELD WELDING OR BOLTING TO MEET THE TOLERANCES
REQUIRED BY OTHER TRADES, WHICH MAY BE MORE STRINGENT THAN A.I.S.C. TOLERANCES FOR
7. IMPORTANT: AFTER DRILLING, ALL DUST AND OTHER FOREIGN MATTER SHALL BE BLOWN OUT OF THE HOLE WITH STRUCTURAL STEEL CONTRACTOR SHALL COORDINATE TRADES AND FIELD INSTALL MISCELLANEOUS
COMPRESSED AIR. DO NOT FLUSH WITH WATER. CLEAN SIDES OF HOLE AS RECOMMENDED BY MANUFACTURER. STEEL ELEMENTS AND THE STRUCTURAL STEEL FRAME TO COMPLY WITH THE TOLERANCE CRITERIA FOR
HOLES MUST BE DRY. PROPER INSTALLATION OF MATERIALS BY OTHER TRADES.
8. ALL ABANDONED HOLES DRILLED IN THE CONCRETE SHALL BE COMPLETELY FILLED WITH NONSHRINK GROUT.

9. INSTALLATION OF DOWELS AND RODS SHALL BE CONTINUOUSLY INSPECTED BY THE TESTING LABORATORY, TO
ENSURE THAT HOLES ARE OF PROPER DIAMETER AND LENGTH, ARE PROPERLY
CLEANED, AND THAT ANCHORS ARE
INSTALLED CORRECTLY. SCALE
1/8" = 1'-0" DATE
08/16/13
10. HOLES IN CONNECTION PLATES SHALL BE NO MORE THAN 1/16" LARGER THAN THE ANCHOR DIAMETER. IF LARGER 3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER
DIAMETER HOLES ARE NECESSARY FOR ERECTION PURPOSES, THE CONTRACTOR SHALL PROVIDE PLATE WASHERS
SUFFICIENTLY WELDED TO THE CONNECTION PLATE TO TRANSFER THE SPECIFIED LOAD.
DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S003
9/26/2013 8:29:55 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
FD FD FD

FD
Lake|Flato
UP
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com
CONCRETE TOPPING = 125 PSF (AVG.) STAIR = 5 PSF STAIR = 5 PSF

FD
P-T SLAB = 10 PSF CONCRETE FLOOR = 15 PSF
FD FD FD

PLAZA = 75 PSF

CONCRETE FLOOR WITH


ARCH'L/MEP TOPPING = 90 PSF PROJECT CONSULTANT

PLANT/BOULDER
LANDSCAPING = 650 PSF

PROJECT CONSULTANT

LEVEL P2 DEAD LOADS LEVEL P1 DEAD LOADS LEVEL 1 DEAD LOADS


1 SCALE 1/32" = 1'-0" 2 SCALE 1/32" = 1'-0" 3 SCALE 1/32" = 1'-0"

STAIR = 5 PSF

CONCRETE FLOOR = 15 PSF STAIR = 5 PSF

LOADING DOCK, CONCRETE FRAMING STAIR = 5 PSF READING PORCH = 10 PSF


WITH ARCH'L TOPPING = 90 PSF
READING PORCH, CONCRETE BRIDGE = 20
CANOPIES = 10 PSF PSF NO. DATE DESCRIPTION
CONCRETE FRAMING WITH REVISIONS
CONCRETE FRAMING WITH
RAISED FLOORING = 25 PSF
RAISED FLOORING = 25 PSF
CONCRETE FRAMING WITH
CONCRETE FRAMING WITH
ARCH'L TOPPING = 90 PSF
ARCH'L TOPPING = 90 PSF

LEVEL 2 DEAD LOADS LEVEL 3 DEAD LOADS LEVEL 4 DEAD LOADS


4 SCALE 1/32" = 1'-0" 5 SCALE 1/32" = 1'-0" 6 SCALE 1/32" = 1'-0"

KEY PLAN

CITY OF AUSTIN

OWNER
DEAD LOADING NOTES:

UP 1. DEAD LOADS DEPICTED IN LOAD DIAGRAMS INCLUDE SUPERIMPOSED DEAD LOADS SUCH AS NEW CENTRAL LIBRARY
ARCH'L TOPPING AND FLOOR/CEILING FINISHES. STRUCTURE SELF-WIEGHT IS NOT INCLUDED.
DN CIP ID#7235.001
2. VERIFY LOCATIONS OF TOPPING AND FINISHES ON THE ARCHITECTURAL DRAWINGS. NOTIFY W. CESAR CHAVEZ BLVD.
ENGINEER OF ANY DISCREPANCIES. AUSTIN, TX
PROJECT

3. SEE S006 FOR ROOF LOADS AND TEMPORARY PLAZA CONSTRUCTION LOADS.

SUPERIMPOSED FLOOR DEAD


LOAD DIAGRAMS
DRAWING TITLE
FD
CIP ID#7235.001

STAIR = 5 PSF

STAIR = 5 PSF CANOPIES = 10 PSF


N
CONCRETE BRIDGE, FLAT
READING PORCH ROOF = 10 PSF SLAB & FINISH = 15 PSF
CONCRETE BRIDGE, FLAT CONCRETE FRAMING WITH
SLAB & FINISH = 15 PSF RAISED FLOORING = 25 PSF

CONCRETE FRAMING WITH CONCRETE FRAMING WITH


RAISED FLOORING = 25 PSF ARCH'L TOPPING = 90 PSF
SCALE
1/32" = 1'-0" DATE
08/16/13
CONCRETE FRAMING WITH ROOF GARDEN = 100 PSF
ARCH'L TOPPING = 90 PSF 3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

7
LEVEL 5 DEAD LOADS
8
LEVEL 6 DEAD LOADS S004
8/14/2013 11:44:35 PM

SCALE 1/32" = 1'-0" SCALE 1/32" = 1'-0"

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
FD FD FD

FD

UP
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
STORAGE, MECH'L,
HEAVY STORAGE = 250 PSF LIGHT STORAGE = 125 PSF T:617.423.1700
STACKS = 150 PSF www.ShepleyBulfinch.com
CORRIDORS, ASSEMBLY, PARKING GARAGE (PASSENGER CORRIDORS, ASSEMBLY, PLAZA,
TYPICAL = 100 PSF FD VEHICLES ONLY) = 40 PSF TYPICAL = 100 PSF
FD FD FD
PARKING GARAGE (PASSENGER INACCESSIBLE AREA
VEHICLES ONLY) = 40 PSF OVERHEAD RAMP = 20 PSF

PROJECT CONSULTANT

NOTE: SEE S006 FOR


PLAZA CONSTRUCTION
LOADS NOT SHOWN HERE

PROJECT CONSULTANT

LEVEL P2 LIVE LOADS LEVEL P1 LIVE LOADS LEVEL 1 LIVE LOADS


1 SCALE 1/32" = 1'-0" 2 SCALE 1/32" = 1'-0" 3 SCALE 1/32" = 1'-0"

STORAGE, DOCK, & STORAGE, LIBRARY / STORAGE, LIBRARY /


STACKS = 150 PSF STACKS = 150 PSF STACKS = 150 PSF

LOBBY, CORRIDORS, CAFE, READING PORCH, CORRIDORS, READING PORCH, CORRIDORS,


GALLERY, TYPICAL = 100 PSF SOUTH CANTILEVER = 100 PSF SOUTH CANTILEVER = 100 PSF

CANOPIES = 20 PSF

NO. DATE DESCRIPTION


REVISIONS

LEVEL 2 LIVE LOADS LEVEL 3 LIVE LOADS LEVEL 4 LIVE LOADS


4 SCALE 1/32" = 1'-0" 5 SCALE 1/32" = 1'-0" 6 SCALE 1/32" = 1'-0"

KEY PLAN

LIVE LOADING NOTES: CITY OF AUSTIN


1. ALL LIVE LOADS COMPLY WITH THE BUILDING CODE (2009 IBC).

2. VERIFY LIVE LOADS WITH SPACE USAGES IDENTIFIED ON THE ARCHITECTURAL


UP DRAWINGS. NOTIFY ENGINEER OF ANY DISCREPANCIES. OWNER
DN
3. IN ACCORDANCE WITH THE IBC, PARKING GARAGE USE IS RESTRICTED TO
PASSENGER VEHICLES ACCOMODATING NO MORE THAN 9 PASSENGERS, AND
NEW CENTRAL LIBRARY
HAVING A WHEEL LOAD NO MORE THAN 3,000 POUNDS. CIP ID#7235.001
4. IN ACCORDANCE WITH THE IBC, LIBRARY STACK LOADING APPLIES TO STACK W. CESAR CHAVEZ BLVD.
ROOM FLOORS THAT SUPPORT NONMOBILE, DOUBLE-FACED LIBRARY PROJECT
AUSTIN, TX
BOOKSTACKS, SUBJECT TO THE FOLLOWING LIMITATIONS:

A) THE NOMINAL BOOKSTACK UNIT HEIGHT SHALL NOT EXCEED 90 INCHES;

FD B) THE NOMINAL SHELF DEPTH SHALL NOT EXCEED 12 INCHES FOR EACH FLOOR LIVE LOAD DIAGRAMS
FACE; AND
DRAWING TITLE
C) PARALLEL ROWS OF DOUBLE-FACED BOOKSTACKS SHALL BE
CIP ID#7235.001

STORAGE, LIBRARY / STORAGE, LIBRARY /


STACKS = 150 PSF SEPARATED BY AISLES NOT LESS THAN 36 INCHES WIDE.
STACKS = 150 PSF
ROOF GARDEN, CORRIDORS,
CORRIDORS = 100 PSF BRIDGES = 100 PSF N
CANOPIES = 20 PSF CANOPIES = 20 PSF

SCALE
1/32" = 1'-0" DATE
08/16/13

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

LEVEL 5 LIVE LOADS LEVEL 6 LIVE LOADS


7 SCALE 1/32" = 1'-0" 8 SCALE 1/32" = 1'-0"
S005
8/14/2013 11:45:03 PM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

ROOF = 30 PSF
PROJECT CONSULTANT

ROOF, MECHANICAL
MEZZANINE = 30 PSF

PV ARBOR = 15 PSF

CONSTRUCTION LOADING NOTES:


LOW ROOF BELOW
1. HATCHED AREA MAY BE USED TO SUPPORT BOOM LIFT(S) DURING CONSTRUCTION.

2. BOOM LIFT(S) SHALL COMPLY WITH THE FOLLOWING PARAMETERS:

LOW ROOF & MEZZ DEAD LOADS HIGH ROOF DEAD LOADS BOOM LIFT TYPE: GENIE SELF-PROPELLED
1 SCALE 1/32" = 1'-0" 2 SCALE 1/32" = 1'-0"
A.
B.
TELESCOPIC BOOM, ULTRA SERIES "1350 SJP"
MAXIMUM WEIGHT = 45,000 LBS
C. MAXIMUM TIRE BEARING PRESSURE = 107 PSI
D. MAX DRIVE SPEED = 3.25 MPH

3. IF MULTIPLE BOOM LIFTS ARE USED, THEY SHALL BE SPACED A MINIMUM


OF 45 FT APART AT ALL TIMES.

4. IF ANY OF THE ABOVE CRITERIA CANNOT BE MET, CONTRACTOR SHALL


SHORE PLAZA SLAB TO GROUND (LEVEL P2) TO SUPPORT BOOM LIFT(S).

NOTE: SEE DEAD AND LIVE LOADING


NOTES ON S004 AND S005 FOR
ADDITIONAL INFORMATION.

NO. DATE DESCRIPTION


REVISIONS

KEY PLAN
ROOF = 20 PSF
CITY OF AUSTIN

MECHANICAL = 150 PSF OWNER

ROOF = 20 PSF
NEW CENTRAL LIBRARY
CIP ID#7235.001
PV ARBOR = 10 PSF W. CESAR CHAVEZ BLVD.
PROJECT
AUSTIN, TX

ROOF DEAD & LIVE LOADS,


PLAZA = BOOM LIFT AND L1 CONSTRUCTION
LOAD DIAGRAMS
DRAWING TITLE
CIP ID#7235.001

LOW ROOF BELOW


N

LOW ROOF & MEZZ LIVE LOADS HIGH ROOF LIVE LOADS LEVEL 1 CONSTRUCTION LOADS
3 SCALE 1/32" = 1'-0" 4 SCALE 1/32" = 1'-0" 5 SCALE 1/32" = 1'-0" 1/32" = 1'-0" 08/16/13
SCALE DATE

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S006
8/14/2013 11:45:10 PM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
A A.3 B C D E F G H J

236' - 7 3/4" 13' - 2 1/4"


Lake|Flato
12' - 9" 12' - 5" 29' - 9" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 14' - 10" 15' - 2" 311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com
2' - 2 3/4"
Shepley Bulfinch Richardson & Abbott
2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

Y1 Y2 Y3

2' - 6"
72
2' - 6"

PROJECT CONSULTANT

.50

68
72
°

.00
.50

°
°
1 1

20' - 9 1/2"
FD
18' - 3"

14' - 6"

14' - 6"
PERIMETER CONCRETE DROPPED MAT SLAB 13'
-9 3/8" PROJECT CONSULTANT
BASEMENT WALL - TYPICAL BELOW RECESSED
ELEVATOR PIT
2 2
2' - 6"

"
1' - 0
2' - 0"

17.50°
BOLLARD PER OF T

4' - 1 7/8"
ARCH'L - TYPICAL TE EX
A A
30' - 0"

T
S

S
X1

30' - 0"
LIMITS OF CRANE INTERIOR CONCRETE
FOUNDATION SHEAR WALL - JOELLE S. ROSENTSWIEG

1/4"
TYPICAL

R
PR
89451

E
2

E
L

32' -

O
3 3 IC
ENSE
D

N
F
E
S G

17.50°
S N
ONAL E

70' - 1 3/8"
26' - 0"

26' - 0"
FD FD

5/8"
X2

4
75' -
6"
27' -
4 4

17.50°
FD

BOTTOM OF
30' - 0"

30' - 0"
LOWER LEVEL

3/8"
RAMP
FD X3

8
14' -
UP

5 5
13' - 0"

13' - 0"

223' - 0"
223'-0"

MATCHLINE:
197' - 1 1/2"

REF. S101.1 NORTH


6 6
REF. S101.2 SOUTH
PLAN NOTES:
2' - 3"

65' - 2"
1. VERIFY ALL DIMENSIONS AND ELEVATIONS WITH
ARCHITECTURAL.
30' - 0"

30' - 0"
RECESSED SUMP 5'-6" CAST-IN-PLACE CONCRETE MAT SLAB FOUNDATION
PER PLUMBING WITH 4" MIN SLOPED CONCRETE TOPPING
(TYPICAL U.N.O.) 2. "T.O.S.C." INDICATES TOP OF STRUCTURAL CONCRETE
ELEVATION. NOTE THAT SLAB SLOPES FOR DRAINAGE.

3. SEE LOADING DIAGRAMS FOR DESIGN LOAD 1 09/26/2013 ADDENDUM #2


INFORMATION. NO. DATE DESCRIPTION
7 7 REVISIONS
DROPPED MAT SLAB BELOW 4. SEE ARCHITECTURAL FOR WATERPROOFING BELOW
CONCRETE WALL RECESSED ELEVATOR PIT MAT SLAB AND BEHIND PERIMETER BASEMENT WALLS.
PILASTER - TYPICAL
5. CONSTRUCTION BELOW MAT SLAB: 4" THICK
30' - 0"

30' - 0"
UNREINFORCED MUD SLAB SHALL BE PLACED OVER
FD RECESSED FD
EXCAVATION. WATERPROOFING SHALL THEN BE
ELEVATOR PIT
CONCRETE COLUMN - Z INSTALLED AND A 4" THICK FIBER-REINFORCED WORK
TYPICAL SLAB SHALL COVER WATERPROOFING. MAT SLAB

5.00°
SHALL BE CONSTRUCTED OVER WORK SLAB.
8 8 6. SEE MEP DRAWINGS FOR PIPE & DRAIN WORK TO
13' - 7 1/2"

PENETRATE THROUGH OR BE EMBEDDED IN MAT SLAB

14' - 0"
CAST-IN-PLACE FOUNDATION.
8.9 CONCRETE STAIRS - TYP 1
Z LIMITS OF CRANE

62' - 9 1/4"
9 FOUNDATION 9 DELETED
9"
4 1/2"

RAISED CONCRETE
16' - 0"

16' - 0"
CURB PER ARCH'L
7. “CX” INDICATES CONCRETE COLUMN. SEE COLUMN
SCHEDULE AND TYPICAL DETAILS (COLUMN LABELS ARE
10 10 SHOWN ONLY ON THE LOWEST FLOOR LEVEL THEY KEY PLAN
9' - 4 1/2"

OCCUR).
CITY OF AUSTIN

15' - 0"
FD
8. "FD" INDICATES FLOOR DRAIN PER MAT SLAB TYPICAL
7' - 7 1/2"

FD DETAILS. SEE SLAB SLOPE PLANS FOR FLOOR DRAIN


DIMENSIONS AND ELEVATIONS.
11 11
9. “PX” INDICATES CONCRETE WALL PILASTER. SEE OWNER
2' - 0"
5' - 7 1/2"

2' - 0"
COLUMN SCHEDULE AND TYPICAL DETAILS.

PROPERTY LINE
NEW CENTRAL LIBRARY
10. “SWX” INDICATES SHEAR WALL. "SW-WP" INDICATES
PER CIVIL & ARCH'L SHEAR WALL WORK POINT. SEE SHEAR WALL CIP ID#7235.001
SCHEDULE, ENLARGED PLANS AND TYPICAL DETAILS. W. CESAR CHAVEZ BLVD.
AUSTIN, TX
11. SEE MAT SLAB REINFORCING PLAN FOR TYPICAL PROJECT

REINFORCEMENT. SEE COLUMN AND WALL TYPICAL


DETAILS FOR ADDITIONAL REINFORCING REQUIREMENTS.

1' - 9 1/2"
12. SEE S200 FOR COMMON SCHEDULES AND DETAILS. SEE
SHEET S201 THRU S203 FOR MAT SLAB FOUNDATION
LEVEL P2 - COMPOSITE PLAN
2' - 6" 2' - 3" DETAILS AND NOTES.
12' - 5" 16' - 4 1/2" 13' - 4 1/2" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 13' - 0 1/2" DRAWING TITLE
CIP ID#7235.001

13. SEE SHEETS S211 THRU S215 FOR BASEMENT WALL


3' - 3 1/2" SCHEDULE AND DETAILS.
10' - 1" 197' - 10 5/8"
14. REFER TO ARCHITECTURAL DRAWINGS FOR RAISED
211' - 3" CONCRETE CURB AND INTERIOR WALL DIMENSIONS AND
ELEVATIONS.
N
3.00°
15. THESE PLAN NOTES APPLY TO SUBSEQUENT
ENLARGED PLANS S101.1 THRU S101.4.
A A.3 A.6 B C D E F G Y4 H 16. SEE ENLARGED PLANS ON S101.1 AND S101.2 FOR MAT
SLAB INFORMATION. SEE ENLARGED PLANS ON 101.3
AND S101.4 FOR SLOPED TOPPING SLAB INFORMATION.
SCALE
As indicated DATE
08/16/13
17. "CJ" INDICATES CONTROL JOINT IN TOPPING SLAB (SEE
3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

TOPPING PLANS). JOB NUMBER

DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS


LEVEL P2 - COMPOSITE PLAN
1 SCALE 1/16" = 1'-0"

S101
9/26/2013 8:30:05 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

G
A A.3 B C D E F H J
PROJECT CONSULTANT
236' - 7 3/4" 13' - 2 1/4"

2' - 2 3/4"
12' - 9" 12' - 5" 29' - 9" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 14' - 10" 15' - 2"
OF T
TE EX
Y1 Y2 Y3 A A

T
S

S
1
1
2' - 6"

S214

72

68
.50
S213

72

.00
423' - 0" JOELLE S. ROSENTSWIEG

°
.50

°
°

R
PR
89451

E
E
L

O
IC D
ENSE

N
F
E
1 1 S
S N
G

2' - 6"
ONAL E
P1 P1 P1 P1 P1 P3 P1 P2

6' - 11"
424' - 6" 2
RAISED CONCRETE CURB PER ARCH'L -

SW4
FD CAST-IN-PLACE CONCRETE RECESSED ELEVATOR PIT S214
SEE TYPICAL DETAILS FOR REINFORCING
18' - 3"

EXTERIOR BASEMENT

20' - 9 1/2"
14' - 6"

14' - 6"
WALL - TYPICAL DROPPED MAT SLAB 13'
2 -93
BELOW ELEVATOR PIT 13' /8"
S213 -03
/8"

P1 C43 C1 C1 C2 C2 C2 C2 C3 9"
2 2
3
1' - 3"

S214

"
1' - 0
4' - 1 7/8"
2' - 6" 6' - 4" 8' - 6"
P4

4' - 1 7/8"
5'-6" CAST-IN-PLACE MAT SLAB FOUNDATION - SEE MAT SLAB
REINFORCING PLAN AND OTHER TYPICAL DETAILS FOR
ADDITIONAL REINFORCING @ COLUMNS, WALLS, ETC.

85.
(TYPICAL U.N.O.) X1

50°
30' - 0"

30' - 0"
7' - 3" 21' - 3"

1 T.O.S.C. EL. = 428' - 4"


PROVIDE ADD'L REINF'G EACH WAY
TOP & BOT. - SEE COLUMN S202
SCHEDULE & MAT SLAB TYPICAL (CAN BE ADJUSTED TO
CONCRETE COLUMN - LIMITS OF CRANE
DETAILS FOR ADD'L INFORMATION INCORPORATE TOPPING SLAB
SEE SCHEDULE & FOUNDATION

1/4"
AT CONTRACTOR'S OPTION)
TYPICAL DETAILS

2
32' -
SW-WP

3' - 3"
P1 C1 C4 C5 C6 C7 C8 C9
3 3
BUILT-UP SLAB SW-WP
5 1 09/26/2013 ADDENDUM #2
FOR ELEVATOR C11 NO. DATE DESCRIPTION
7
S213 PIT - SEE ARCH'L SW-WP

11' - 0"
S201 REVISIONS

SW3
FLOOR DRAIN - STRUCTURAL SHEAR WALL -

70' - 1 3/8"
25' - 3"
26' - 0"

26' - 0"
SEE MAT SLAB SEE SHEAR WALL ENLARGED
SW2

PLAN & TYPICAL CRANE CENTERLINE PLANS & TYPICAL DETAILS

5/8"
X2
SW1

DETAILS - TYPICAL FD

4
6

75' -
FD STRUCTURAL SHEAR WALLS - SEE 7' - 0"
SHEAR WALL ENLARGED PLANS, S213
CRANE FOUNDATION ANCHORS
97' - 9"

ELEVATIONS & TYPICAL DETAILS 2' - 8 1/2"

1' - 3 1/4"
3' - 0"

6"
27' -
P1 C10 C13 C11 C12 C18 C14 C15 C32
4 3 4
S201
C11

GRIDS YPICAL @
& X3
FD
CONCRETE WALL PILASTER AT

X1, X2
BASEMENT WALLS - SEE
12' -

T
SCHEDULE & TYPICAL DETAILS 15' - 4 3/4" 14' - 7 1/4" 8' - 9" 8 5/8"
KEY PLAN

17.50° -
BOLLARD PER ARCH'L - SEE
MAT SLAB TYPICAL DETAILS
CITY OF AUSTIN
FOR BOLLARD ANCHORAGE
30' - 0"

30' - 0"
2

24' - 6"
X3
S201

3/8"
8
OWNER
4 BOTTOM OF LOWER LEVEL RAMP -

14' -
7
SEE RAMP PLANS AND DETAILS
S213 FD S213 NEW CENTRAL LIBRARY
9
CIP ID#7235.001
S222 W. CESAR CHAVEZ BLVD.
CAST-IN-PLACE CONCRETE
PROJECT
AUSTIN, TX
STAIR PER ARCH'L - SEE STAIR
P1 C10 C16 C19 C42 C17 C15
TYPICAL DETAILS FOR REINF'G
5

20' - 11 1/4"
5 C20 8
ENLARGED LEVEL P2 -
2' - 6"

S212
NORTH
13' - 0"

13' - 0"
2' - 6" 2' - 3" DRAWING TITLE
1
CIP ID#7235.001

P1 C1 C21 C21 C7 C22 C44 C46 C24


6
MATCHLINE: RE. 1/S101.2
6 N
6' - 2 1/2"

DROPPED MAT
SLAB BELOW SUMP

1 1/8" = 1'-0" 08/16/13


(BLOS) DESIGNATIONS HAVE BEEN DELETED SCALE DATE

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

A A.3 B C D E F G H SEE SHEET S101 FOR PLAN NOTES Author Checker


DRAWN CHECKED
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

PARKING LEVEL P2 ENLARGED PLAN - NORTH S101.1


9/26/2013 8:30:09 AM

1 SCALE 1/8" = 1'-0"

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
A A.3 B C D E F G H

2' - 6"
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com
5
8 Shepley Bulfinch Richardson & Abbott
5 2 Seaport Lane, Boston, Massachusetts 02210
S212
T:617.423.1700
www.ShepleyBulfinch.com

1
66" Mat Slab

P1 C1 C21 C21 C7 C22 C44 C46 C24 MATCHLINE: RE. 1/S101.1


6 6
6' - 2 1/2"
8' - 0"

PROJECT CONSULTANT
DROPPED MAT CONCRETE COLUMN -
SLAB BELOW SUMP SEE SCHEDULE & TYPICAL DETAILS
8
S213
30' - 0"

30' - 0"
48" DIA X 6'-0' PRECAST PROJECT CONSULTANT

SUMP RECESSED INTO MAT


SLAB - SEE PLUMBING
8
DRAWINGS FOR ADD'L INFO.
S203 T.O.S.C. EL. = 428' - 4"

44' - 2 3/4"
S215 1 (CAN BE ADJUSTED TO OF T
TE EX
INCORPORATE TOPPING SLAB A A

T
S

S
AT CONTRACTOR'S OPTION)

JOELLE S. ROSENTSWIEG
P1 C1 C23 C25 C26 C27 C27 C28
7 7

R
PR
89451

E
E
L

O
IC D
ENSE

N
F
2 E
4 S G
S N
S202 PROVIDE ADD'L REINF'G EACH WAY ONAL E

13' - 0"
S202
CONCRETE WALL PILASTER AT 12' - 0" TOP & BOTTOM - SEE COLUMN
BASEMENT WALLS - SEE 1' - 6" 8' - 6" SCHEDULE & MAT SLAB TYPICAL
SCHEDULE & TYPICAL DETAILS DETAILS FOR ADD'L INFORMATION
DROPPED MAT SLAB
3 423' - 0" BELOW ELEVATOR PIT
S213 5'-6" CAST-IN-PLACE MAT SLAB FOUNDATION
FD FD
30' - 0"

30' - 0"
REINFORCED WITH #11'S @ 12" O.C. EACH WAY TOP & BOTTOM,
424' - 6"
8' - 11"

6' - 11"
AND WWM 4x4-W2.9xW2.9 AT TOP OF MAT
SW5

6" (TYPICAL U.N.O.)


3
FLOOR DRAIN PER
S202 MAT SLAB TYPICAL
DETAILS - TYPICAL
Z
107' - 0"

SW-WP RECESSED ELEVATOR PIT

5.00°
STRUCTURAL SHEAR WALL - SEE
SHEAR WALL ENLARGED PLANS &
P3 C15 C29 TYPICAL DETAILS C30 C31 C33 C34 C35
8 8
13' - 7 1/2"

14' - 0"
CAST-IN-PLACE CONCRETE BOLLARD PER ARCH'L -
STAIR PER ARCH'L - SEE SEE MAT SLAB TYPICAL
STAIR TYPICAL DETAILS DETAILS FOR BOLLARD 9" 28' - 6" 9"
P5
FOR REINFORCING ANCHORAGE
8.9 14' - 3" 14' - 3"
Z C20
1

62' - 9 1/4"
9 9
3' - 0"

S202
FD
4 1/2"

9"
1 09/26/2013 ADDENDUM #2
16' - 0"

16' - 0"
NO. DATE DESCRIPTION
LIMITS OF CRANE REVISIONS
14' - 3"

FOUNDATION
4
S214
C36
C20 C36 C36 C36 C36
10 10
28' - 6"

C36

CRANE CENTERLINE
RAISED CONCRETE
FD
15' - 0"

15' - 0"
CURB PER ARCH'L -
14' - 3"

FLOOR DRAIN - SEE CRANE FOUNDATION ANCHORS SEE TYPICAL DETAILS


PLAN & TYPICAL MAT FOR REINFORCING
SLAB DETAILS BASEMENT WALLS PER
7' - 7 1/2"

FD SCHEDULE - TYPICAL

11 11
2' - 0"

2' - 0"
9 5 KEY PLAN

10 S213 S214
S213 1' - 9 1/2" CITY OF AUSTIN
2' - 6" 12' - 5" 16' - 4 1/2" 13' - 4 1/2" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 13' - 0 1/2" 2' - 3"

3' - 3 1/2" OWNER


10' - 1" 197' - 10 5/8"

NEW CENTRAL LIBRARY


SEE SHEET S101 FOR PLAN NOTES
A A.3 A.6 B C D E F G H CIP ID#7235.001
3.00° W. CESAR CHAVEZ BLVD.
1 PROJECT
AUSTIN, TX
(BLOS) DESIGNATIONS HAVE BEEN DELETED
Y4

ENLARGED LEVEL P2 -
SOUTH
DRAWING TITLE

PARKING LEVEL P2 ENLARGED PLAN - SOUTH


CIP ID#7235.001

1 SCALE 1/8" = 1'-0"

SCALE
1/8" = 1'-0" DATE
08/16/13

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S101.2
9/26/2013 8:30:12 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

A A.3 B C D E F G H J PROJECT CONSULTANT

Y3
236' - 7 3/4" 13' - 2 1/4"

2' - 2 3/4"
12' - 9" 12' - 5" 29' - 9" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 14' - 10" 15' - 2"
PROJECT CONSULTANT

Y2
Y1
7 3/8"
2' - 6"

72
6' - 1 1/4"

.50

68
72
OF T

.00
.50
TE EX
A

°
°
A

T
S

S
2' - 6"
1 1

RIDGE LINE
6' - 4 3/4"

JOELLE S. ROSENTSWIEG

R
PR
89451

E
E
RECESSED TOPPING L

O
18' - 3"

IC D
ENSE

N
20' - 9 1/2"
RIDGE LINE

F
14' - 6"

14' - 6"
E
AT AREAWAY T.O. TOPPING EL. = 429' - 6" EL. = 429' - 6" S G
S N
AND SLOPED TO DRAIN 13' ONAL E
FD -93
13' /8"
RAISED CURB 429' - 6" 4' - 7 1/4" -03
/8"
PER ARCH'L
CJ 9"
2 2

4' - 0"
RIDGE LINE

4' - 1 7/8"
"
17.50°
(TYPICAL UNLESS SHOWN OTHERWISE)

1' - 0
CONTROL JOINT IN TOPPING RIDGE LINE
VALLEY LINE IN SLOPED
EQUAL

RIDGE LINE
PER MAT SLAB TYPICAL SLOPED CONCRETE TOPPING (THICKNESS SMALL ARROWS
CONCRETE TOPPING

RIDGE LINE
DETAILS - TYPICAL VARIES FROM 4" TO 14") SEE GENERAL INDICATE WARPED AREAS
NOTES FOR REINFORCEMENT TO TRANSITION FROM
EQUAL EQUAL FLAT TO SLOPED SLAB

(TYPICAL UNLESS SHOWN OTHERWISE) T.O. TOPPING EL. = 429' - 6" X1


30' - 0"

30' - 0"
CJ
NE

2' - 0"
LI

VA
VA

EY

LL
LL

LL

EY
EY

T.O. TOPPING EL. = 429' - 6"


VA
EQUAL

RIDGE LINE IN SLOPED

CJ
LIN
LIN

CONCRETE TOPPING EL. = 429' - 6"

E
E

1/4"
LIN
CJ

CJ

CJ

CJ

CJ

2
EY
PROVIDE DIAGONAL BARS AT

32' -
LL
RE-ENTRANT CORNERS - SEE

VA

CJ
CJ TOPPING TYPICAL DETAILS
3 3

1' - 6"

CJ

CJ

CJ

CJ
T.O. TOPPING EL. = 429' - 6"
1' - 6" 1 09/26/2013 ADDENDUM #2

17.50°
CJ

CJ

CJ

CJ

4' - 7 1/4" NO. DATE DESCRIPTION


4' - 3"

70' - 1 3/8"
T.O. TOPPING EL. = 429' - 6" T.O. TOPPING EL. = 428' - 8" REVISIONS
T.O. TOPPING EL. = 428' - 8"
26' - 0"

26' - 0"
CJ
X2

5/8"
RIDGE LINE RIDGE LINE 5' - 3
"

4
FD FD

75' -
INE
RIDGE LINE

WALL PER
97' - 9"

YL
11' - 0"

11' - 0"
ARCH'L - TYP VA

LLE
VA

LL

5' - 1 5/8"
E
VA
EY
LL

T.O. TOPPING EL. = 429' - 6"

6"
E LIN
3' - 0"
EY

LIN

27' -
E
LIN

CJ

RIDG
4 4
E

SEE ARCH'L & LANDSCAPING


DWG'S FOR PLANTER RECESSES
FD

1' - 0"
WITHIN TOPPING DEPTH (NOT
SHOWN HERE) - TYP. AROUND
1' - 0" EAST & SW TERRACED PLANTERS
E
LIN

17.50°
Y TOPPING BLOCK-OUT
LLE T.O. TOPPING EL. = 429' - 6"
FOR RAMP - SEE
VA RAMP DETAILS
30' - 0"

30' - 0"
CJ 24' - 6" CJ 3' - 0" X3 KEY PLAN

1' - 0 1/4"

3/8"
RIDGE LINE

CITY OF AUSTIN

5' - 0"

8
T.O. TOPPING EL. = 429' - 6" TOPPING BLOCKOUT FOR 2' - 2 5/8"

14' -
RIDGE LINE TO FOLLOW STAIR CONSTRUCTION FD
CJ

WALLS - SEE ARCH'L


RIDGE LINE IN SLOPED
CONCRETE TOPPING FOR WALL LOCATIONS

72
"
5' - 0

.50
OWNER

°
1' - 1
RIDGE LINE RIDGE LINE 1"
BLOCK-OUT FOR PLANTER WALL - TYP.
1
NEW CENTRAL LIBRARY

2' - 6"
5
(SEE ARCH'L FOR WALL GEOMETRY)
5 CIP ID#7235.001

20' - 11 1/4"
CJ W. CESAR CHAVEZ BLVD.
21' - 3"
T.O. TOPPING EL. = 429' - 6" AUSTIN, TX
T.O. TOPPING EL. = 429' - 6" PROJECT

BOLLARD PER ARCH'L - SEE


13' - 0"

13' - 0"
MAT SLAB TYPICAL DETAILS
FOR BOLLARD ANCHORAGE
14" Concrete
Topping
LEVEL P2 TOPPING PLAN -
NORTH
6 6 DRAWING TITLE
CIP ID#7235.001

CJ MATCHLINE: RE. 1/S101.2


SEE SHEET S101 FOR PLAN NOTES

N
A A.3 B C D E F G H

SCALE
1/8" = 1'-0" DATE
08/16/13

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

PARKING LEVEL P2 TOPPING PLAN - NORTH


1 DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

SCALE 1/8" = 1'-0"


PACKAGE 2 CONSTRUCTION DOCUMENTS

S101.3
9/26/2013 8:30:17 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
A A.3 B C D E F G H T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

5 5
CJ

T.O. TOPPING EL. = 429' - 6"

PROJECT CONSULTANT
14" Concrete
Topping

MATCHLINE: RE. 1/S101.3


6 6
CJ
OF T
TE EX
A A
CONTROL JOINT IN

T
S

S
TOPPING - SEE CONCRETE COLUMN -
TYPICAL DETAILS SEE SCHEDULE
JOELLE S. ROSENTSWIEG

R
PR
89451
CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

E
E
L

O
IC D
ENSE

N
F
E
SUMP
30' - 0"

30' - 0"
S G
E S
ONAL E
N

Y LIN
CJ LE
L
VA VALLEY LINE IN SLOPED
CONCRETE TOPPING
SMALL ARROWS INDICATE

44' - 2 3/4"
SLOPED CONCRETE TOPPING (THICKNESS
VA

WARPED AREAS TO T.O. TOPPING EL. = 429' - 6"

VA
LL

TRANSITION FROM FLAT - VARIES FROM 4" TO 14") SEE GENERAL

LL
EY

NOTES FOR REINFORCEMENT

EY
TO SLOPED - SLAB
LIN

E
LI

LIN
NE
E

EY
LL
VA
7 7
CJ

428' - 10" 1' - 6"

(TYPICAL UNLESS NOTED OTHERWISE)


RIDGE LINE

EQUAL
WALL PER T.O. TOPPING EL. = 429' - 6"
3' - 0" ARCH'L - TYP
T.O. TOPPING EL. = 428' - 8"
T.O. TOPPING EL. = 428' - 8"
30' - 0"

30' - 0"
FD FD
CJ
RIDGE LINE IN SLOPED
CONCRETE TOPPING
EQUAL EQUAL

EQUAL
107' - 0"

T.O. TOPPING EL. = 429' - 6"


(TYPICAL UNLESS NOTED OTHERWISE)
428' - 10"

5.00°
E
LIN

CJ
8 8 1 09/26/2013 ADDENDUM #2
EY

VA
NO. DATE DESCRIPTION
LL

LL
VA

REVISIONS

EY
NE
1' - 8"

LIN
13' - 7 1/2"

13' - 7 1/2"
VA

LI
LL

EY

E
5' - 0" EY

LL
LIN VALLEY LINE IN SLOPED

VA
E CONCRETE TOPPING
2' - 11 1/8"

4 1/2"
8.9
8.9
Z CJ
0"

62' - 9 1/4"
9 - 9
5'
T.O. TOPPING EL. VARIES
00°
4 1/2"

BOLLARD PER ARCH'L - SEE


45.
2' - 7 1/8"

MAT SLAB TYPICAL DETAILS


FOR BOLLARD ANCHORAGE
4' - 5 1/8"
16' - 0"

16' - 0"
TOPPING BLOCKOUT FOR
STAIR CONSTRUCTION 5' - 10 3/4"

BLOCK-OUT FOR PLANTER


WALL - TYP. (SEE ARCH'L
FOR WALL GEOMETRY)
10 10
CJ RAISED CURB

7' - 9 3/4"
KEY PLAN
PER ARCH'L
CITY OF AUSTIN
1 4' - 9"
15' - 0"

15' - 0"
3' - 0" SEE ARCH'L & LANDSCAPING DWG'S FD
FOR PLANTER RECESSES WITHIN
TOPPING DEPTH (NOT SHOWN RECESSED TOPPING 428' - 8"
T.O. TOPPING EL. = 429' - 6"
HERE) - TYP. AROUND EAST & SW AT AREAWAY AND
7' - 7 1/2"

FD
4' - 9"

OWNER
TERRACED PLANTERS SLOPED TO DRAIN
3' - 0"

FD
11 11 NEW CENTRAL LIBRARY
CIP ID#7235.001

2' - 0"
2' - 0"

3.00°
W. CESAR CHAVEZ BLVD.
AUSTIN, TX
4 5/8" PROJECT

1' - 9 1/2"

2' - 6" 12' - 5" 16' - 4 1/2" 13' - 4 1/2" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 13' - 0 1/2" 2' - 3" LEVEL P2 TOPPING PLAN -
SOUTH
3' - 3 1/2" DRAWING TITLE
10' - 1" 197' - 10 5/8"
CIP ID#7235.001

SEE SHEET S101 FOR PLAN NOTES


Y4
A A.3 A.6 B C D E F G H
N

PARKING LEVEL P2 TOPPING PLAN - SOUTH


1 SCALE 1/8" = 1'-0"

SCALE
1/8" = 1'-0" DATE
08/16/13

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S101.4
9/26/2013 8:30:21 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
A A.3 B C D E F G H J

236' - 7 3/4" 13' - 2 1/4"


Lake|Flato
12' - 9" 12' - 5" 29' - 9" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 14' - 10" 311 Third Street, San Antonio , Texas 78205
15' - 2" T:210.227.3335
www.LakeFlato.com
2' - 2 3/4"
Shepley Bulfinch Richardson & Abbott
2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

Y1
Y2 Y3
2' - 6"

PROJECT CONSULTANT

2' - 6"
72

72

68
.50

.50

.00
°

°
1 1
13'
OPEN -9

20' - 9 1/2"

20' - 9 1/2"
3/8"
18' - 3"

~ SLAB OPENING @
14' - 6"

14' - 6"
OPEN ELEVATOR SHAFT FD PROJECT CONSULTANT

2 2

4' - 1 7/8"
LEAVE-OUT

"
1' - 0
CONSTRUCTION JOINT &
2' - 0"

17.50°
POUR STRIP EDGE OF P-T'd SLAB OF T
TE EX

4' - 1 7/8"
BOLLARDS A A
30' - 0"

T
PER ARCH'L

S
QUADRANT 1 QUADRANT 3
X1

30' - 0"
SLAB INFILL SLAB TO BE CAST SLAB
AFTER REMOVAL OF JOELLE S. ROSENTSWIEG

1/4"
CONSTRUCTION CRANE

R
PR
89451

E
E
32' -
L

O
3 3 IC
ENSE
D

N
F
E
S G
S N

17.50°
ONAL E

70' - 1 3/8"
PERIMETER BASEMENT
26' - 0"

26' - 0"
WALL - TYPICAL

5/8"
FD
FD
X2

4
SHEAR WALLS -

75' -
TYPICAL

6"
4 4

27' -
17.50°
FD
SLOPED CONCRETE

~
30' - 0"

30' - 0"
OPEN

3/8"
TOP OF LOWER
LEVEL RAMP SLAB BOTTOM OF UPPER X3

8
OPEN
LEVEL RAMP SLAB

14' -
MATCHLINE: REF. S102.1 NORTH
5 5
REF. S102.2 SOUTH
13' - 0"

13' - 0"

223' - 0"
223'-0"

~
197' - 1 1/2"

CAST-IN-PLACE
6 CONCRETE STAIR 6
(CAST AFTER
CONSTRUCTION JOINT & POUR STRIP
EDGE OF P-T'd SLAB 2' - 3"
CONCRETE WALL

65' - 2"
PILASTER - TYPICAL 9" CAST-IN-PLACE POST-TENSIONED FLAT SLAB
30' - 0"

30' - 0"
LEAVE-OUT POUR STRIP (TYPICAL U.N.O.)
PLAN NOTES:

T.O.S.C. EL. VARIES 1. VERIFY ALL DIMENSIONS AND ELEVATIONS WITH


SEE S102.3 & S102.4 ARCHITECTURAL.
1 09/26/2013 ADDENDUM #2
NO. DATE DESCRIPTION
7 7 2. “T.O.S.C.” INDICATES TOP OF STRUCTURAL
CONCRETE ELEVATION. NOTE THAT LEVEL P1 SLAB REVISIONS
SLOPES FOR DRAINAGE.
QUADRANT 2 CONCRETE COLUMN - QUADRANT 4
FD SLAB TYPICAL SLAB
3. SEE LOADING DIAGRAMS FOR DESIGN LOAD
30' - 0"

30' - 0"
INFORMATION.
FD
OPEN SLAB OPENING @
CONSTRUCTION JT & 4. SEE MEP DRAWINGS FOR PIPE AND DRAIN WORK TO
ELEVATOR SHAFT Z
INTERMEDIATE PENETRATE THE FLOOR FRAMING (NOT SHOWN HERE).
TENDON ANCHORAGE

5.00°
5. SEE COLUMN STUD RAIL DETAILS FOR STUD RAIL
LOCATIONS AND ADDITIONAL INFORMATION.
8 8
13' - 7 1/2"

6. “CX” INDICATES CONCRETE COLUMN. SEE COLUMN

14' - 0"
SCHEDULE AND TYPICAL DETAILS (COLUMN LABELS ARE
FD SHOWN ONLY ON THE LOWEST FLOOR LEVEL THEY

62' - 9 1/4"
Z OCCUR).
9 9
CAST-IN-PLACE CONCRETE CURB 7. "FD" INDICATES FLOOR DRAIN PER TYPICAL DETAILS. SEE
4 1/2"

POST-TENSIONED BEAM
16' - 0"

16' - 0"
8.9 CONCRETE STAIR FRAMING BELOW - TYP PER ARCH'L SLAB SLOPE PLANS FOR FLOOR DRAIN DIMENSIONS AND
ELEVATIONS.

8. “PX” INDICATES CONCRETE WALL PILASTER. SEE


10 10 COLUMN SCHEDULE AND TYPICAL DETAILS.
KEY PLAN

. CITY OF AUSTIN
15' - 0"

15' - 0"
OPEN INFILL SLAB TO BE CAST 9. “SWX” INDICATES SHEAR WALL WORK POINT. SEE SHEAR
AFTER REMOVAL OF OPEN WALL SCHEDULE, ENLARGED PLANS AND TYPICAL
CONSTRUCTION CRANE DETAILS.
11 11
10. BEAM LABELS ARE SHOWN AS "XY-N" ON THE PLANS,
7' - 7 1/2"

OWNER
WHERE "X" INDICATES A NEARBY NORTH-SOUTH GRID,
2' - 0"

2' - 0"
1' - 10 1/2" "Y" INDICATES A NEARBY EAST-WEST GRID, AND "N"
INDICATES A UNIQUE BEAM NUMBER IN THAT AREA. NEW CENTRAL LIBRARY
1 11. INFILL STRIPS SHALL BE CAST 60 DAYS AFTER POST-
CIP ID#7235.001
TENSIONED SLAB IS TENSIONED. LEVEL P1 SLAB SHALL W. CESAR CHAVEZ BLVD.
REMAIN LATERALLY BRACED UNTIL INFILL SLABS ARE AUSTIN, TX
PROJECT
CAST AND HAVE ACHIEVED 75% OF THEIR FULL DESIGN
STRENGTH. CONSTRUCTION OF FRAMING ABOVE MAY
CONTINUE DURING THIS TIME SO LONG AS ACCESS IS
MAINTAINED TO THE LOWER LEVELS SO INFILL SLABS
CAN BE FORMED AND CAST AS SPECIFIED. LEVEL P1 - COMPOSITE PLAN
12. SLAB TENDON LAYOUT IS SHOWN SCHEMATICALLY.
12' - 5" 16' - 4 1/2" 13' - 4 1/2" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 14' - 10" 2' - 3" FINAL TENDON LAYOUT SHALL BE DETERMINED BY DRAWING TITLE
CIP ID#7235.001

2' - 6" CONTRACTOR AND SUBMITTED TO ENGINEER FOR


10' - 1" 201' - 2" APPROVAL.

13. SEE S200 FOR COMMON SCHEDULES AND DETAILS.


211' - 3" N
14. SEE SHEETS S211 THRU S215 FOR BASEMENT WALL
3.00° SCHEDULE AND DETAILS.

15. REFER ARCHITECTURAL DRAWINGS FOR RAISED CURB


A A.3 A.6 B C D E F G Y4 H AND INTERIOR WALL DIMENSIONS.

16. THESE PLAN NOTES APPLY TO SUBSEQUENT


ENLARGED PLANS S102.1 THRU S102.4. As indicated 08/16/13
SCALE DATE

17. SEE ENLARGED PLANS S102.1 AND S102.2 FOR


3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

LEVEL P1 - COMPOSITE PLAN STRUCTURAL INFORMATION AND SEE ENLARGED PLANS JOB NUMBER

1 SCALE 1/16" = 1'-0"


S102.3 AND S102.4 FOR SLAB SLOPE INFORMATION.
DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

18. POST-TENSIONED SLAB SHALL BE CAST IN TWO PHASES.


CAST SLAB QUADRANTS 1 AND 2 AND ALLOW TO CURE PACKAGE 2 CONSTRUCTION DOCUMENTS
AS DIRECTED IN THE STRUCTURAL GENERAL NOTES.
STRESS TENDONS AT INTERMEDIATE TENDON
ANCHORAGES AND THEN CAST SLAB QUADRANTS 3
AND 4.
S102
9/26/2013 8:30:25 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
MILD REINFORCEMENT LEGEND FOR
P1 LEAVE-OUT AND INFILL SLABS:

S1
#4 @ 6" O.C. E.W.
TOP & BOTTOM

S2
#6 @ 6" O.C. E.W.
TOP & BOTTOM

Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

A A.3 B C D E F G H J
236' - 7 3/4" 13' - 2 1/4"
2' - 2 3/4" PROJECT CONSULTANT

12' - 9" 12' - 5" 29' - 9" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 14' - 10" 15' - 2"

Y1 Y2 Y3
1
2' - 6" 1 PROJECT CONSULTANT
(TYP.) S214 17.50°
2' - 6"

S213

72

68
.50

.00
°

°
OF T
1 1 TE EX
A

2' - 6"
A

T
6' - 11"

S
OPEN SLAB OPENING AT S1 7' - 7" 8' - 0 3/4" 2

11' - 3"

SW4
PA2-1

RAISED CONCRETE CURB BASEMENT WALLS PER ELEVATOR SHAFT S214


9" Concrete
18' - 3"

PER ARCH'L - SEE TYPICAL SCHEDULE - TYPICAL

20' - 9 1/2"
14' - 6"

14' - 6"
JOELLE S. ROSENTSWIEG
OPEN DETAILS FOR REINF'G
FD

R
6' - 4" 8' - 6" ~

PR
2 (TYP @ LEAVE-OUT STRIP U.N.O.) 13' 89451

E
-9 3/8"

E
L

O
IC D
S213 ENSE

N
F
E
S G

4' - 0"
S N
ONAL E

3
2 2

10
S214

7.5

1' - 3"

9 SEE COLUMN STUD RAIL DETAILS CONSTRUCTION JOINT & HATCH PATTERN INDICATES
BOLLARD PER ARCH'L - SEE

4' - 1 7/8"
(TYP.) S402 FOR STUD RAIL LOCATIONS AND EDGE OF POST- CAST-IN-PLACE LEAVE-OUT

17.50°
COLUMN BELOW - TYP
ADD'L INFO. P-T SLAB TYPICAL DETAILS TENSIONED SLAB POUR-STRIP TO BE CAST 60
FOR BOLLARD ANCHORAGE DAYS OR LATER AFTER
TENDONS ARE STRESSED P-T SLAB EAST OF
GRID G & NORTH OF
GRID X3: PROVIDE #5'S
CONSTRUCTION JOINT & AT 12" O.C. EACH WAY
UNIFORM DRAPED TENDONS INTERMEDIATE TENDON ANCHORAGE - ~ ~ ~ TOP & BOTTOM
30' - 0"

30' - 0"
"
IN NORTH-SOUTH DIRECTION, SEE TYPICAL P-T SLAB DETAILS X1

1' - 0
S2

~
SEE PT SLAB SCHEDULE - TYP
10' - 0"

~
BANDED DRAPED TENDONS SPACED 9" CAST-IN-PLACE TWO-WAY 1' - 6" QUADRANT 3

~
OVER A 4'-0" WIDTH & CENTERED POST-TENSIONED FLAT SLAB 11' - 0" 17' - 6" SLAB
9' - 2" 4' - 0" OVER COLUMN GRIDLINE ON EACH ~ ~ ~ (EAST OF GRID H &
(TYPICAL U.N.O.) 7' - 7" NORTH OF GRID X2)
GRID IN EAST-WEST DIRECTION, SEE

1/4"
PT SLAB SCHEDULE - TYPICAL CONCRETE COLUMN - SLAB OPENING & INFILL

2
SEE SCHEDULE & SLAB TO ACCOMMODATE

32' -
TYPICAL DETAILS CONSTRUCTION CRANE PD3-1
3 3

5' - 6"
5
S213 SEE P-T BEAM TYPICAL
QUADRANT 1 OPEN DETAIL FOR BEAM POST-
SLAB TENSION INFO.
1

SW3

17.50°
#4's AT 18" O.C. EACH WAY AT S1 STRUCTURAL SHEAR WALL -

11' - 0"
BOTTOM OF SLAB - TYP BUILT-UP SLAB SEE ENLARGED PLANS &

70' - 1 3/8"
FOR ELEVATOR
26' - 0"

26' - 0"
~ ~ ~ U.N.O. TYPICAL DETAILS - TYPICAL 4' - 0
PIT - SEE ARCH'L

SW2
" 1 09/26/2013 ADDENDUM #2

5/8"
9" INFILL SLAB TO BE CAST AFTER
~

FD FD X2 NO. DATE DESCRIPTION


REMOVAL OF CONSTRUCTION CRANE

4
SW1

REVISIONS
~

75' -
PD4-1
S213
~

~
97' - 9"

7 BEAM CL
~ ~ ~
S403 4
GUARDRAIL PER ARCH'L
15' - 4 3/4"

6"
~ (NOT SHOWN HERE) S403

27' -
7' - 9
3/4"
4 4
SWALE TO
~

MATCH RAMP

"
3' - 0"

2' - 6
~
FD

3/4"
CONCRETE WALL PILASTER -
TYPICAL AT BASEMENT WALLS BOTTOM OF UPPER

0
8' - 1
SEE TYPICAL DETAILS 4' - 2 1/2" RAMP SLAB - SEE RAMP
FOR REINFORCING PLANS & DETALS 15

17.50°
PLACEMENT AT COLUMNS GUARDRAIL PER S413 6
THICKENED & SLOPED ARCH'L (NOT

"
S403
RC5-2

1' - 2
RAMP BEAM - SEE SLAB - SEE RAMP PLANS SHOWN HERE)
30' - 0"

30' - 0"
24' - 6"

OPEN RAMP PLAN & DETAILS & DETAILS X3


OPEN

3/8"
CAST-IN-PLACE CONCRETE STAIR TO
2

8
4 LEVEL 1 ABOVE PER ARCH'L - SEE STAIR 1' - 3"

14' -
TYPICAL DETAILS FOR REINFORCING 7
S403 KEY PLAN
S213
S213
9 BEGIN LOWER LEVEL
NO NORTH-SOUTH TENDONS IN PORTION OF 9 13' - 7" CITY OF AUSTIN
SLAB DIRECTLY SOUTH OF RAMP - PROVIDE 3 UP
S415 RAMP SLAB - SEE RAMP S403
TENDONS IN EAST-WEST DIRECTION & #6'S S403 2' - 3"
PLANS & DETAILS @ 6" O.C. EACH WAY TOP & BOTTOM

OWNER
10
5 5

20' - 11 1/4"
3' - 0"
S402 OPEN
~ 1' - 3" 5" NEW CENTRAL LIBRARY
2' - 6"

8
5' - 0"

1' - 3"
62' - 11 1/2" RAMP OPENING 6' - 6" 10' - 6 1/2" S212
CIP ID#7235.001

9' - 0"
5' - 0"
8
13' - 0"

13' - 0"
3' - 0"

~ S403 W. CESAR CHAVEZ BLVD.


~
PROJECT
AUSTIN, TX
2' - 6"
5' - 0"

1' - 3"

1' - 0"
MATCHLINE: RE. 1/S102.2
6 6 ENLARGED LEVEL P1 -
NORTH
CAST-IN-PLACE LEAVE-OUT STRIP
TO BE CAST 60 DAYS OR LATER DRAWING TITLE
CIP ID#7235.001

AFTER TENDONS ARE STRESSED

N
~

A A.3 B C D E F G H SEE SHEET S102 FOR PLAN NOTES

SCALE
1/8" = 1'-0" DATE
08/16/13

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

PARKING LEVEL P1 ENLARGED PLAN - NORTH


1 DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

SCALE 1/8" = 1'-0"


PACKAGE 2 CONSTRUCTION DOCUMENTS

S102.1
9/26/2013 8:30:29 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
MILD REINFORCEMENT LEGEND FOR
P1 SLAB REINFORCEMENT
P1 LEAVE-OUT LEGEND:
AND INFILL SLABS:

S1
#4 @ 6" O.C. E.W.
TOP & BOTTOM

S2
#6 @ 6" O.C. E.W.
TOP & BOTTOM

Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com
A A.3 B9 C D E F G H
S415
Shepley Bulfinch Richardson & Abbott
2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com
UP

UP
10
5

3' - 0"
S402
~ 1' - 3" 5" OPEN
8

5' - 0"
5
S212

9' - 0"
5' - 0"
8 PROJECT CONSULTANT

3' - 0"
~ S403
~

5' - 0"
1' - 3"

1' - 0"
6 6
MATCHLINE: RE. 1/S102.1 PROJECT CONSULTANT

CAST-IN-PLACE LEAVE-OUT STRIP CAST-IN-PLACE CONCRETE


TO BE CAST 60 DAYS OR LATER STAIRS TO LEVEL P2 BELOW PER
AFTER TENDONS ARE STRESSED ARCH'L - SEE STAIR TYPICAL
UNIFORM DRAPED TENDONS IN UNIFORM DRAPED TENDONS IN DETAILS FOR REINFORCING 8 OF T
CONSTRUCTION JOINT & EDGE TE EX
BASEMENT WALL PER NORTH-SOUTH DIRECTION, NORTH-SOUTH DIRECTION, S213 A A

T
SEE PT SLAB SCHEDULE - TYP OF POST-TENSIONED SLAB SEE PT SLAB SCHEDULE - TYP

S
SCHEDULE - TYPICAL
30' - 0"

30' - 0"
CAST-IN-PLACE LEAVE-OUT STRIP
~

S1 JOELLE S. ROSENTSWIEG
TO BE CAST 60 DAYS OR LATER #4 AT 18" O.C. EACH

R
WAY AT BOTTOM OF

PR
AFTER TENDONS ARE STRESSED 89451
9" CAST-IN-PLACE TWO-WAY

E
SLAB - TYP U.N.O.

E
L

O
POST-TENSIONED FLAT SLAB IC
ENSE
D

N
F
E

44' - 2 3/4"
S G
CONSTRUCTION JOINT (TYPICAL U.N.O.) ~ ~ ~ S
ONAL E
N
& EDGE OF POST- (TYP @ LEAVE-

~
8' - 11" 4' - 0" TENSIONED SLAB BOLLARD PER ARCH'L - SEE SEE COLUMN STUD RAIL OUT STRIP U.N.O.)

~
P-T SLAB TYPICAL DETAILS DETAILS FOR STUD RAIL
FOR BOLLARD ANCHORAGE LOCATIONS AND ADD'L INFO.

~
~
~ ~ ~

7 7
2

~
S415 ~
BANDED TENDONS SPACED

13'-0"
OVER A 4'-0" WIDTH & SEE TYPICAL DETAILS
1' - 6" 8' - 6"
CENTERED OVER COLUMN FOR REINFORCING
GRIDLINE ON EA GRID IN QUADRANT 2 PLACEMENT AT COLUMNS QUADRANT 4
FD SLAB SLAB 3' - 9" 12' - 0"
EAST-WEST DIRECTION, SEE
3 PT SLAB SCHEDULE - TYP 10' - 0"
S213
30' - 0"

30' - 0"
FD
6'-11"
SW5

4
99' - 4 1/2"

CONSTRUCTION JOINT &


S415 INTERMEDIATE TENDON FLOOR DRAIN - SEE P-T
ANCHORAGE - SEE TYPICAL SLAB TYPICAL DETAILS
2
P-T SLAB DETAILS Z
SLAB OPENING AT ELEVATOR S418
SHAFT

5.00°
STRUCTURAL SHEAR WALL - SEE
SHEAR WALL ENLARGED PLANS & TYP.
DETAILS
8 8

11' - 2"
13' - 7 1/2"

12' - 9"

CONCRETE COLUMNS - RAISED CONCRETE CURB

14' - 0"
SEE SCHEDULE & 1 09/26/2013 ADDENDUM #2
PER ARCH'L - SEE TYPICAL
1 SEE P-T BEAM TYPICAL TYPICAL DETAILS FD NO. DATE DESCRIPTION
1 DETAILS FOR REINF'G - TYP
DETAIL FOR BEAM POST- REVISIONS
P9 S403
8.9 TENSIONING INFO

PD10-1
2' - 5 3/8"

Z PLACE 2/3 OF REQUIRED TENDONS


PC10-1

ADD'L TENDONS TO MAKE

62' - 9 1/4"
9 UP FOR THE INTERRUPTED FOR GRID 10 UNIFORMLY OVER 9
CAST-IN-PLACE CONCRETE STAIRS BANDED TENDONS 9'-6" 11'-0" 9'-6" TRIBUTARY WIDTH NORTH OF GRID 10
4 1/2"

TO LEVEL P2 BELOW & LEVEL 1


ABOVE PER ARCH'L - SEE STAIR SLAB OPENING & INFILL
TYPICAL DETAILS FOR REINFORCING SLAB TO ACCOMMODATE
PA

CONSTRUCTION CRANE
16' - 0"

16' - 0"
9-
1

1' - 3"
PC10-2 13' - 1 1/4"
4'
-
8"

10 S1 10
11'-0"

5
0"

6
-

S403
1'

6' S417
- 10 RAISED CONCRETE CURB BELOW
0"

"
15' - 0"

15' - 0"
EXTERIOR WALL - SEE ARCH'L FOR
-

PLACE 1/3 OF REQUIRED


5'

14' - 3"
OPEN S1 DIM'S & ELEV'S - SEE FLAT SLAB
TENDONS FOR GRID 10 OPEN KEY PLAN

11' - 0"
TYPICAL DETAILS FOR REINF'G
9" Concrete OVER COLUMNS (BANDED)
8'-3"

CITY OF AUSTIN
7' - 7 1/2"

(TYP @ LEAVE- OUT STRIP U.N.O.)


11 11
2' - 0"

OWNER

2' - 0"
9 5 NEW CENTRAL LIBRARY
1' - 10 1/2" S213 S214 CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
1' - 9 1/2"
PROJECT
AUSTIN, TX
2' - 3"
12' - 5" 16' - 4 1/2" 13' - 4 1/2" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 13' - 0 1/2"

2' - 6" 10' - 1" 201' - 2" ENLARGED LEVEL P1 -


SOUTH
3.00°
DRAWING TITLE
CIP ID#7235.001

SEE SHEET S102 FOR PLAN NOTES.


A A.3 A.6 B C D E F G Y4 H
N

PARKING LEVEL P1 ENLARGED PLAN - SOUTH 1/8" = 1'-0" 08/16/13


1 SCALE 1/8" = 1'-0"
SCALE DATE

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S102.2
9/26/2013 8:30:32 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

G
A A.3 B C D E F H J Y3
236' - 7 3/4" 13' - 2 1/4"
PROJECT CONSULTANT

2' - 2 3/4"
12' - 9" 12' - 5" 29' - 9" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 14' - 10" 15' - 2"

Y1
PROJECT CONSULTANT

2' - 6"
2' - 6"

72

72
.50

68
.50
°

.00
°

2' - 6"

°
1 1
RIDGE LINE

439' - 6"

6' - 9"
9"
8' - 1"

T.O.S.C. EL. = 439' - 6" OPEN SLAB OPENING AT


ELEVATOR SHAFT
18' - 3"

20' - 9 1/2"
14' - 6"

14' - 6"
RIDGE LINE

RIDGE LINE
OPEN 7 3/8" FD
13'
-9 3/8"
RIDGE LINE Y2
EL. = 439' - 6"
439' - 6"

2 2

10
RIDGE LINE

7.5
4' - 0"
CONSTRUCTION JT & EDGE


16' - 2 3/8" OF POST-TENSIONED SLAB
1' - 3"

17.50°
RIDGE LINE
CONSTRUCTION JOINT &
INTERMEDIATE TENDON ANCHORAGE
9" CAST-IN-PLACE POST-

4' - 1 7/8"
TENSIONED FLAT SLAB -
TYPICAL U.N.O.

X1
30' - 0"

30' - 0"
"
T.O.S.C. EL. = 439' - 6"

1' - 0
VA

VA
VALLEY LINE IN
NE
LLE

T.O.S.C. EL. = 439' - 6"

LL
LI SLOPED P-T SLAB

EY
RIDGE LINE
YL

EY

RIDGE LINE
LL

LIN
INE

VA

E
6' - 0
"

1/4"
E
LIN
SLAB OPENING & INFILL

2
SLAB TO ACCOMMODATE

EY

32' -
WALL PER WALL PER

LL
CONSTRUCTION CRANE
ARCH'L - TYP.

VA
ARCH'L - TYP.
3 3

OPEN

"
5' - 7
T.O.S.C. EL. = 439' - 6" 1' - 6" 1' - 6"
5' - 3"

17.50°
1/4"

70' - 1 3/8"
6' - 3
T.O.S.C. EL. = 438' - 8" T.O.S.C. EL. = 438' - 8"
26' - 0"

26' - 0"
NO. DATE DESCRIPTION

5/8"
X2 REVISIONS
RIDGE LINE FD

4
FD 439' - 6" 4' - 1

75' -
5/8" 5' - 0
"

INE
E
97' - 9"

11' - 3"

11' - 3"
E LIN

YL
EL. = 439' - 6"

LLE
4' - 3 1/4" 6' - 5 1/4" 10' - 6 1/2"

5' - 1 5/8"
VA
RIDG
VA

VA
LLE

6"
SEE RAMP PLAN
LL

YL

27' -
INE
EY

FOR SLOPES
LIN

4 4
E

T.O.S.C. EL. = 439' - 6"


FD
1' - 0"

2' - 0"
T.O.S.C. EL. = 439' - 6"
E BEGIN SLOPE
LIN 439' - 6"

17.50°
Y FOR RAMP
LLE
VA
RIDGE LINE
30' - 0"

30' - 0"
439' - 6" X3
OPEN

3/8"
8
KEY PLAN

14' -
RIDGE LINE IN BEGIN RAMP
CITY OF AUSTIN
T.O.S.C. EL. = 439' - 6" SLOPED P-T SLAB CONCRETE 439' - 6" OPEN
T.O.S.C. EL. = 439' - 6" SEE ARCHITECTURAL
FOR TOP OF SLAB UP
RIDGE LINE RIDGE LINE ELEV'S IN THIS AREA
OWNER

5 5 NEW CENTRAL LIBRARY

20' - 11 1/4"
2' - 6"

CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
13' - 0"

13' - 0"
PROJECT
AUSTIN, TX
2' - 6"
CONSTRUCTION JOINT & EDGE
OF POST-TENSIONED SLAB LEVEL P1 SLAB SLOPE PLAN
6 6
MATCHLINE: RE. 1/S102.4 - NORTH
DRAWING TITLE
CIP ID#7235.001

N
A A.3 B C D E F G H Y4
SEE SHEET S102 FOR PLAN NOTES

SCALE
1/8" = 1'-0" DATE
08/16/13

PARKING LEVEL P1 SLAB SLOPE PLAN - NORTH 3860


C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

1 SCALE 1/8" = 1'-0" DRAWN


Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S102.3
8/14/2013 11:45:44 PM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
A A.3 B C D E F G H 311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

5 5
OPEN

PROJECT CONSULTANT

CONSTRUCTION JOINT & EDGE


OF POST-TENSIONED SLAB MATCHLINE: RE. 1/S102.3
6 6

SEE ARCH'L FOR

RIDGE LINE
TOP OF SLAB PROJECT CONSULTANT

ELEV'S IN THIS AREA

E VALLEY LINE IN
Y LIN SLOPED P-T SLAB
LLE 2' - 3"
VA
30' - 0"

30' - 0"
T.O.S.C. EL. = 439' - 6"
VA
LL

44' - 2 3/4"
WALL PER
EY

6' - 7 1/4" 3' - 0"


ARCH'L - TYP.

VA
LIN

LL
E

EY

NE
LI

LI
NE

EY
LL
VA
7 7
T.O.S.C. EL. = 439' - 6"

8' - 8 3/8"
T.O.S.C. EL. = 438' - 8" 9' - 10"
1' - 6"

FD

6' - 0"
9" CAST-IN-PLACE POST- T.O.S.C. EL. = 438' - 8"
TENSIONED FLAT SLAB
30' - 0"

30' - 0"
(TYPICAL U.N.O.)
1' - 6" FD
99' - 4 1/2"

RIDGE LINE IN CONSTRUCTION JOINT &


T.O.S.C. EL. = 439' - 6" INTERMEDIATE TENDON
SLOPED P-T SLAB
15' - 3 5/8"
ANCHORAGE

15' - 0"
E
LIN

439' - 6"
EY

1' - 10"

5.00°
LL
VA

4"
8 8
3' - 0"

VA
LL

7' - 10"
EY
NE
10' - 7 5/8"

LIN
13' - 7 1/2"

LI
EY

14' - 0"
E

13' - 8"
LL
VA
VA FD
LL
EY
LIN
E
Z NO. DATE DESCRIPTION

11 1/2"

62' - 9 1/4"
9 9 REVISIONS

8.9 SLAB OPENING & INFILL SLAB TO


4 1/2"

ACCOMMODATE CONSTRUCTION CRANE 8' - 6 1/8"


16' - 0"

16' - 0"
CONSTRUCTION JOINT & EDGE
OF POST-TENSIONED SLAB
10 LANDING EL. = 440' - 0" 10
15' - 0"

15' - 0"
OPEN
OPEN
T.O.S.C. EL. = 439' - 6"
7' - 7 1/2"

KEY PLAN

11 11 CITY OF AUSTIN
2' - 0"

2' - 0"
OWNER

NEW CENTRAL LIBRARY


1' - 9 1/2"
2' - 6"
2' - 3"
CIP ID#7235.001
12' - 5" 16' - 4 1/2" 13' - 4 1/2" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 13' - 0 1/2" W. CESAR CHAVEZ BLVD.
10' - 1" PROJECT
AUSTIN, TX

3.00° LEVEL P1 SLAB SLOPE PLAN


A A.3 A.6 B C D E F G H - SOUTH
Y4 SEE SHEET S102 FOR PLAN NOTES
DRAWING TITLE
CIP ID#7235.001

1/8" = 1'-0" 08/16/13


PARKING LEVEL P1 SLAB SLOPE PLAN - SOUTH SCALE DATE

1 3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

SCALE 1/8" = 1'-0" JOB NUMBER

DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S102.4
8/15/2013 12:12:42 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
450'-0"

449'-11"
449'-11"
A A.3 B C D E F F.1 G H J

236' - 7 3/4" 450'-1"

12' - 9" 12' - 5" 29' - 9" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 28' - 0" 14' - 10" 15' - 2"

451'-10" Lake|Flato

VAR
2' - 0" 2' - 2 3/4" 311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
Y1 Y2 Y3 449'-11" www.ShepleyBulfinch.com

451'-6" 450'-0"
2' - 6"

2' - 6"
72

72

68
450'-1"

.50

.50

.00
°
VAR ~

°
452'-0" SLOPED
1 1 451'-10"
OPEN

20' - 9 1/2"
OPEN
18' - 3"

14' - 6"

14' - 6"
PROJECT CONSULTANT
OPEN
FD 451'-6"
FD FD FD
2 2 452'-0"

SLOPED
VAR ~
17.50°
CONCRETE FD VARIES ~ SLOPED PROJECT CONSULTANT
VAULT WALLS T.O.S.C. EL. = 450' - 1"
30' - 0"

FD
PERIMETER SLAB
BASEMENT WALL - FD
DEPRESSION X1

30' - 0"
TYPICAL FD
INFILL SLAB TO BE CAST
OF T

1/4"
AFTER REMOVAL OF TE EX
A A
CONSTRUCTION CRANE

T
2

S
32' -
3 FD 3

17.50°
OPEN
INTERIOR CONCRETE JOELLE S. ROSENTSWIEG

74' - 3 1/4"
SHEAR WALL - TYPICAL TYPICAL DETAIL

R
26' - 0"

26' - 0"

PR
89451
FD

E
L1 STRUCTURAL SLAB ELEVATION SCHEMATIC

E
L

O
T.O.S.C. EL. = 450' - 1" IC
ENSE
D

N
F
E

OPENING STRUCTURAL
SLAB DROP
X2 2 SCALE 1/32" = 1'-0"
S
S
ONAL E
N
G

PER ARCH'L
FD

6"
4 4

27' -
17.50°

"
1' - 3
30' - 0"

30' - 0"
T.O.S.C. EL. = 451' - 6"
OPEN

3/8"
HATCHED AREAS INDICATE
CONCRETE TOPPING PER
OPEN X3

5
ARCH'L ON TOP OF

13' -
STRUCTURAL SLAB X3.1
5 5
13' - 0"

13' - 0"
223' - 0"

223' - 0"
RECESSED
197' - 1 1/2"

FD ELEVATOR PIT MATCHLINE: REF. S103.1 NORTH


6 6
FD
REF. S103.2 SOUTH
FD STRUCTURAL
~

65' - 2"
FD SLAB DROP
30' - 0"

30' - 0"
FD FD

CONCRETE COLUMN
FD BELOW - TYPICAL

7 7

12" CAST-IN-PLACE
TWO-WAY
1 09/26/2013 ADDENDUM #2
CONCRETE BEAM FRAMING CONCRETE SLAB STRUCTURAL
T.O.S.C. EL. = 452' - 0"
30' - 0"

30' - 0"
SLAB DROP NO. DATE DESCRIPTION
BELOW - TYPICAL (TYPICAL U.N.O.) 0.25:12
OPEN REVISIONS
CONCRETE T.O.S.C. EL. = 451' - 6"
STUB WALL SLAB OPENING @ CONCRETE COLUMN ABOVE - TYPICAL Z
ELEVATOR CONCRETE CURB

5.00°
BELOW EXTERIOR WALL
8 8
14' - 0"

14' - 0"
PLAN NOTES:

62' - 9 1/4"
9 Z 9
1. VERIFY ALL DIMENSIONS AND ELEVATIONS WITH
16" CAST-IN-PLACE ARCHITECTURAL.
16' - 0"

16' - 0"
INFILL SLAB TO BE CAST TWO-WAY CONCRETE
AFTER REMOVAL OF SLAB (TYP AT PLAZA) STEEL POSTS FOR 2. “T.O.S.C.” INDICATES TOP OF STRUCTURAL CONCRETE
CONSTRUCTION CRANE
0.25:12

OPEN READING PORCH ABOVE ELEVATION. SEE ARCHITECTURAL FOR CONCRETE


10 10 TOPPING ELEVATIONS.
7' - 7 1/2"

CAST-IN-PLACE 3. SEE LOADING DIAGRAMS FOR DESIGN LOAD


15' - 0"

15' - 0"
CONCRETE STAIRS INFORMATION.
OPEN
BASEMENT WALL BELOW
4. SEE MEP DRAWINGS FOR PIPE AND DRAIN WORK TO
11 11 PENETRATE THE FLOOR FRAMING. KEY PLAN

CITY OF AUSTIN
2' - 0"

5. SEE COLUMN STUD RAIL DETAILS FOR STUD RAIL

2' - 0"
LOCATIONS AND ADDITIONAL INFORMATION.

6. "CX" INDICATES COLUMN. SEE COLUMN SCHEDULE


AND TYPICAL DETAILS (COLUMN LABELS ARE SHOWN
2' - 6" 1' - 9 1/2" ONLY ON THE LOWEST FLOOR LEVEL THEY OCCUR). OWNER
2' - 3"
12' - 5" 29' - 9" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 13' - 0 1/2"
7. “PX” INDICATES CONCRETE WALL PILASTER. SEE NEW CENTRAL LIBRARY
3' - 3 1/2" COLUMN SCHEDULE AND TYPICAL DETAILS.
10' - 1" 197' - 10 5/8" CIP ID#7235.001
211' - 3" 8. “SWX” INDICATES STRUCTURAL SHEAR WALL. SEE W. CESAR CHAVEZ BLVD.
SHEAR WALL ENLARGED PLANS AND TYPICAL DETAILS. AUSTIN, TX
SEE PLANS S101.1 AND S101.2 FOR LOWER LEVEL PROJECT
3.00°
SHEAR WALL WORK POINTS.

9. BEAM LABELS ARE SHOWN AS "XY-N" ON THE PLANS,


WHERE "X" INDICATES A NEARBY NORTH-SOUTH GRID,
"Y" INDICATES A NEARBY EAST-WEST GRID, AND "N"
LEVEL 1 - COMPOSITE PLAN
INDICATES A UNIQUE BEAM NUMBER IN THAT AREA.
A A.3 B C D E F G Y4 H DRAWING TITLE
CIP ID#7235.001

10. "FD" INDICATES FLOOR DRAIN PER SLAB TYPICAL


DETAILS. SEE ARCHITECTURAL FOR LOCATIONS
(SHOWN HERE SCHEMATICALLY).

11. SEE SLAB TYPICAL REINFORCING PLAN AND OTHER N


SLAB TYPICAL DETAILS FOR REINFORCEMENT
INFORMATION.

12. SEE S200 FOR COMMON SCHEDULES AND DETAILS.

13. SEE SHEETS S211 THRU S215 FOR BASEMENT WALL


SCHEDULE AND DETAILS.
As indicated 08/16/13
14. REFER TO ARCHITECTURAL DRAWINGS FOR TOPPING SCALE DATE

SLAB AND RAISED CURB DIMENSIONS AND


3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

THICKNESSES. ALL TOPPING SLABS AND CURBS ARE JOB NUMBER

LEVEL 1 - COMPOSITE PLAN SHOWN SCHEMATICALLY ON THE STRUCTURAL PLANS.


1 DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

SCALE 1/16" = 1'-0" 15. THESE PLAN NOTES APPLY TO SUBSEQUENT


ENLARGED PLANS S103.1 THRU S103.2. PACKAGE 2 CONSTRUCTION DOCUMENTS
16. SEE ENLARGED PLANS S103.1 AND S103.2 FOR
STRUCTURAL INFORMATION.

S103
9/26/2013 8:30:37 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

A A.3 B C D E F F.1 G H J

236' - 7 3/4" 13' - 2 1/4"

2' - 0"
12' - 9" 12' - 5" 29' - 9" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 28' - 0" 14' - 10" 15' - 2"
PROJECT CONSULTANT
2' - 2 3/4"
6' - 4" 8' - 6" 15' - 2"
Y1
6 2 ~ 10" DIA CHILLED WATER LINES PER AUSTIN ENERGY Y2 Y3
1' - 10 3/8" 1 17.50°
1 S214 TO PENETRATE BASEMENT WALL. PROVIDE 12" MIN
1 S214
S417 CLEAR BETWEEN PENETRATIONS. SEE CIVIL FOR LINE
S213
2' - 6"

ELEVATIONS, SEE ARCH'L FOR WATERPROOFING

72
PROJECT CONSULTANT

68
.50

.00
°

°
1 1

2' - 6"
P6

9"
6' - 5"
OF T
TE
1' - 3"

2
5' - 2"

OPEN EX
OPEN PERIMETER

SW4
A A

T
BASEMENT S214

S
18' - 3"

A2-1

20' - 9 1/2"
C2-1

D2-1
WALL BELOW
14' - 6"

14' - 6"
B2-1
OPEN T.O.S.C. EL. = 450' - 1" 13'
-9 3/8"
2 JOELLE S. ROSENTSWIEG
450' - 0" 13'
S213 -0 3/8"
1' - 3" FD

R
6' - 4" 8' - 6"

PR
FD FD SW-WP 1' - 9 1/8" 89451

E
FD

E
9' - 11" B2-2 C2-2 L

O
IC D
9" ENSE

N
F
E
1' - 3" HOUSEKEEPING PAD S
S N
G
2 PER AUSTIN ENERGY
2 ONAL E
28' - 3
11"
CONCRETE COLUMN S214

8' - 6"
12" THICK CONCRETE BELOW - SEE COLUMN

7/8"

17.50°
10' - 3" VAULT WALLS 449' - 11" TYPICAL DETAILS FOR
(LEVEL 1 TO LEVEL 2)

0
FD TERMINATION INFO - TYP

10' -
°
19' - 2 3/4"

2.50
7

C3-1

D3-1
449' - 11"
B3-1

SLAB DEPRESSION
PER ARCH'L - SEE FLAT SLAB DEPRESSION
T.O.S.C. EL. = 450' - 1"

6' - 2"
10 FD SLAB TYPICAL DETAILS PER ARCH'L - SEE FLAT VAL
FOR REINFORCING SLAB TYPICAL DETAILS LEY 450' - 1"
30' - 0"

30' - 0"
S414 1' - 7 1/4" LIN X1
11 FOR REINFORCING FD E
S414 B3-2 C3-2 SLOPE STRUCTURAL
SLAB IN THIS AREA FD
1' - 6"
11' - 0" 449'-9"
450' - 1"
BM CL 12" THICK CAST-IN-PLACE TWO-WAY
10' - 9 1/4"

CONCRETE PILASTER - SEE ARCH'L FOR 11 CONCRETE FLAT SLAB - SEE L1

1/4"
SEE COLUMN SCHEDULE WALLLOCATION & DIMS SW-WP 1 17.50°

9' - 8 3/8"
S303 SCHEMATIC REINFORCEMENT PLANS PERIMETER

2
& TYPICAL DETAILS SLAB OPENING & INFILL (TYPICAL U.N.O.) S419

32' -
SW-WP SLAB TO ACCOMMODATE BASEMENT
INE
CONSTRUCTION CRANE EYL WALL BELOW
LL
3 VA 3
FD SW-WP

5' - 6"
5 12 SHADED AREAS INDICATE CONCRETE
S413 TOPPING OR BUILT-UP SLAB &
S213 OPEN STYROFOAM FILL OVER STRUCTURAL

VALLEY LINE

17.50°
SLAB - SEE ARCH'L FOR DIM'S &
ELEV'S - SEE FLAT SLAB TYPICAL

SW3
DETAILS FOR STRUCTURAL INFO.

74' - 3 1/4"
6'-1

11' - 0"
CAST-IN-PLACE 1/4"
STRUCTURAL SHEAR WALL - 3" FD

G4-2
CONCRETE BASEMENT 4 1' - 6"

F4-1
26' - 0"

26' - 0"
T.O.S.C. EL. = 450' - 1" SEE ENLARGED PLANS & 3
WALL PER SCHEDULE - TYPICAL DETAILS - TYPICAL STRUCTURAL S419
S419
SLAB DROP SEE ARCH'L FOR
TYPICAL
SLOPED TOPPING

SW2
X2 1 09/26/2013 ADDENDUM #2
SW1

F4-2 6
5'-11 1/4" 3'-8 3/4"

NO. DATE DESCRIPTION

D4-1
S213 REVISIONS

~
97' - 9"

C38 STRUCTURAL
9'-8 1/4"

8 5 2

7' - 3"
STRUCTURAL SLAB DROP

1' - 6"
DIAG. BARS - SEE OPEN

8' - 9"
450' - 1" SLAB DROP S414 S415 S419
RE-ENTRANT CORNER FD 451' - 6"

6"
TYPICAL DETAILS C4-2 D4-2 D4-3

27' -
2' - 2"

A4-1 B4-1
2'-0"

4 2 4
S417 G4-1
E4-1 CONCRETE BLEACHERS 450' - 1"

3/8"
C4-1 451' - 10" & ATRIUM STAIRS TO BE
2' - 6"

"

1
13' - 7"

1' - 9
7'-8" 5'-1 3/4" CONSTRUCTED ON CMU

10' -

17.50°
9 6' - 11 1/4" WALLS - SEE STAIR &

"
8" THICK SLOPING BLEACHER DETAILS

1' - 3
7 S414
8 6 CONCRETE SLAB BEAM CL 15
S415
S415 S415 UPTURNED S413
17' - 4

"
T.O.S.C. EL. = 451' - 6"

2' - 0
EDGE BEAM 9
27' - 6"

6"
5/8"

3/4"
27' - 4"

S322

E5-1

E5-3
30' - 0"

30' - 0"
PROVIDE 3 #8'S @ 3"
26' - 2"

OPENING FOR GARAGE RAMP -

F5-4

2
O.C. AT EDGE OF SLAB

F5-2
SEE RAMP PLANS & DETAILS X3

27' -

3/8"
1/4"
(TOP & BOTTOM) T.O. BEAM EL. = C45
4 SLOPE 3' - 2 1/4" 6 3/4"
453' - 10 7/8" 2' - 0 OPEN

5
0
" 7 X3.1

13' -
10' -
S213 8' - 1
0 3/8" 14 CANOPY BOLLARD - S213
7
9 CONCRETE S413
SEE 6/S703 - TYP. KEY PLAN
S414
7' - 10" ATRIUM STAIRS
S415 1' - 3"
5B CITY OF AUSTIN

5' - 1 3/4" 4' - 11 3/4"


S417 1' - 11 3/4"
7 NOTE: SEE ARCH'L FOR
8"

5 E5-2 F5-1 CURB / STAIR LANDING


S417
GEOMETRY & TOP OF 5

TRANSITION

20' - 11 1/4"
THICKNESS
C39 C39 WALL ELEVATIONS AT
1' - 8"
2' - 6"

F5-3 OWNER
EAST ENTRY OPENING

IN WALL
C5-1 D5-1
END OF MASONRY

A5-1 B5-1 STEEL COL'S

1' - 0 3/4"
WALL THICKNESS

13' - 7" 97' - 10" RAMP OPENING 7' - 10" C9, BP-8 STRUCTURAL NEW CENTRAL LIBRARY
TRANSITION IN

SLAB DROP 451' - 0 7/8"


13' - 0"

13' - 0"
E6-3
TYPICAL @

F6-1
E6-1

CIP ID#7235.001

8' - 6"
C6-1

OPEN VESTIBULE 6 1

2' - 8 1/2"
LEDGE &

1' - 6"
STRUCTURAL S416 W. CESAR CHAVEZ BLVD.

2' - 3"
SLAB DROP S417 451' - 2"
FD 1 PROJECT
AUSTIN, TX
1
6 6
FD MATCHLINE: RE. 1/S103.2

72
10"

.50
E6-2 F6-2 G6-1
ENLARGED LEVEL 1 - NORTH
8' - 4"
SW-WP

°
T.O.S.C. EL. = 451' - 6" 6' - 11"
C7-1

S215 1 OPEN C40 T.O.W. 450' - 8 1/8"


BEAM CL

0"
0.25:12

G7-1
3' - 1
FD 3' - 6" 6' - 6 1/4" DRAWING TITLE
3' - 1
CIP ID#7235.001

0"
T.O.S.C. EL. = 450' - 1" 10' - 5 1/2" STRUCTURAL
F6-3 SLAB DROP

N
F7-1
2' - 3"

A A.3 B C D E F G H
SEE SHEET S103 FOR PLAN NOTES

SCALE
1/8" = 1'-0" DATE
08/16/13

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

LEVEL 1 ENLARGED PLAN - NORTH DRAWN


Author CHECKED
Checker
NEW CENTRAL LIBRARY

1 SCALE 1/8" = 1'-0" PACKAGE 2 CONSTRUCTION DOCUMENTS

S103.1
9/26/2013 8:30:40 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
A A.3 B C D E F G H Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

5B Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
S417
T:617.423.1700
1' - 11 3/4"
7 www.ShepleyBulfinch.com
E5-2 F5-1
S417
5

TRANSITION

THICKNESS
5' - 1 3/4"
C39 C39 F5-3

IN WALL
A5-1 B5-1 C5-1 D5-1 STEEL COL'S

1' - 0 3/4"
5 STRUCTURAL
C9, BP-8
SLAB DROP 451' - 0 7/8"

E6-3
TYPICAL @

F6-1
E6-1

8' - 6"
C6-1
OPEN VESTIBULE 6

2' - 8 1/2"
4

1' - 6"
STRUCTURAL S416

2' - 3"
S417 PROJECT CONSULTANT
SLAB DROP 451' - 2"
FD 1
1 MATCHLINE: RE. 1/S103.1
6 6
FD

72
10"

.50
E6-2 F6-2 G6-1

8' - 4"
SW-WP

°
T.O.S.C. EL. = 451' - 6" 6' - 11" OPEN C40 T.O.W. 450' - 8 1/8"
BEAM CL

0"
0.25:12 PROJECT CONSULTANT

3' - 1
FD 3' - 6" 6' - 6 1/4"
3' - 1 8
2 0"
T.O.S.C. EL. = 450' - 1" 10' - 5 1/2" STRUCTURAL S213
FD
S215 F6-3 SLAB DROP

G7-1
C45 STRUCTURAL

C7-1
OF T

F7-1
2' - 3" TE EX

SW6
30' - 0"

30' - 0"
SHEAR WALL - SEE A A

T
ENLARGED PLANS &

S
FD TYPICAL DETAILS
6
FD 4
2' - 6" S414
1' - 3" S312 JOELLE S. ROSENTSWIEG
FOR MASONRY LEDGE
SEE WALL ELEVATION

28' - 3"

44' - 2 3/4"
S215 1

R
PR
1 89451
FD

E
CONCRETE COLUMN BELOW - SEE 451' - 0 1/2"

E
L

O
IC D
TYPICAL COLUMN DETAILS FOR ENSE

N
F
E
STRUCTURAL TERMINATION INFO - TYPICAL PG
S
S N
G
1' - 6"

ONAL E
SLAB DROP CONCRETE COLUMN 4
ELEVATION DETAIL
CHANGE IN LEDGE

ABOVE - TYPICAL
MASONRY LEDGE
ELEVATION - SEE

B7-1 S416
1 3
STRUCTURAL
7 SLAB DROP S415 7
S417
2 C19
4' - 2"

10' - 0"
S415

13' - 0"
12" THICK CAST-IN-PLACE TWO-
3 1' - 6" WAY CONCRETE FLAT SLAB -

G8-1
A7-1 S415 SEE L1 REINFORCEMENT PLANS
8' - 6" (TYPICAL U.N.O.)
8 STRUCTURAL SHEAR P1
3 T.O.S.C. EL. = 452' - 0" 5
WALL - SEE ENLARGED T.O.W. 450' - 8 1/8"
S416 S416

C8-3
S213 PLANS & TYPICAL DETAILS T.O.S.C. EL. = 451' - 6"
30' - 0"

10' - 0"

30' - 0"
2' - 6"
6' - 11"
B8-1

SW5

7' - C-I-P CONCRETE OPEN T.O.S.C. EL. = 451' - 6"


4 1/8" DIAGONAL STUB WALL 4 SHADED AREAS INDICATE STRUCTURAL
99' - 4 1/2"

CONCRETE TOPPING OR BUILT- SLAB DROP


S415 1
STRUCTURAL UP SLAB OVER STRUCTURAL
13' S418 SLAB - SEE ARCH'L FOR DIM'S
P2
- 6" SLAB DROP
& ELEV'S - SEE FLAT SLAB
1/2"

1' - 6" SW-WP


9' - 10 3/4"

TYPICAL DETAILS FOR REINF'G RAISED CONCRETE CURB BELOW

10' - 0"
EXTERIOR WALL - SEE ARCH'L FOR
7

STRUCTURAL

5.00°
DIM'S & ELEV'S - SEE FLAT SLAB
1' -

451' - 7"
2 1/2"

SLAB DROP Z
B8-2 C8-1 TYPICAL DETAILS FOR REINF'G 451' - 0 5/8"
1/8"

8 8
4' - 10 1/2"
22.50°
5

7' - 1 1/2"
C29
4' -

6' - 11"

10

9' - 3 1/2"
STRUCTURAL C31 T.O. WALL EL. VARIES
~
2' - 9 1/2"

10' - 0"
S415 451' - 4"
A8- SLAB DROP
1 0.25:12
14' - 0"

14' - 0"

14' - 0"
451' - 2 7/8" C30
0.25:12

1 STAIRS ABOVE PER BEAM CL THICKENED SLAB @


LANDSCAPE DWG'S TRANSITION TO PLAZA SLAB

6' - 10"
P3
2' - 0"

7 1 09/26/2013 ADDENDUM #2
C8-2 451' - 2 1/4" D8-1 E8-1 F9-1
Z S416 2
NO. DATE DESCRIPTION
3

62' - 9 1/4"
(TYP) BEAM CL REVISIONS

10' - 0"
9 SLO 9
P S416 S416
CIRCULAR PILASTER REF ED CU 1 STRUCTURAL 451' - 0 5/8"
. AR RB 451' - 0 5/8"
0.25:12

SLAB DROP
2' - 0 1/4"

CH' -
C10-1
B10-1

T.O. SIGN WALL BELOW, ROUND L

G10-1
D10-1

E10-1
BEAM CL 1
23' - 10" ARCHITECTURAL SIGN WALL

ELEV. 457'-9" COLUMN ABOVE 10' - 5 5/8" 3


3 SIM.
13 STRUCTURAL

0.25:12
1 S413 16" THICK CAST-IN-PLACE 2-WAY SLAB DROP
S416 P4
16' - 0"

16' - 0"
S416 CONCRETE FLAT SLAB - SEE L1

F10-1
SCHEMATIC REINFORCEMENT PLANS

8' - 3"
CAST-IN-PLACE CONRETE 1
(TYPICAL AT PLAZA)
4 STAIR PER ARCH'L - SEE STAIR PA PB S413 PC PD
OPEN T.O. WALL EL. = 450' - 8 3/4"
5' - 9"

S214 TYPICAL DETAILS FOR REINF'G C10-2


4' - 3"

B10-2 D10-2 E10-2 F10-2


10 10
11' - 0"

3' - 8"
6
6' - 9"

WALL THICKNESS
S417 1' - 8"

TRANSITION IN
D11-1

STEEL COL C3 / BP-7 - 6' - 10"

E11-1
15' - 0"

15' - 0"
3' - 10 7/8"

SLAB OPENING & INFILL TYPICAL @ PORCH

F11-1
P5
B11-1

SLAB TO ACCOMMODATE

11' - 10"
G11-1
11' - 0" 9' - 6"

1' - 8 1/2"
7 CONSTRUCTION CRANE OPEN

6' - 10"
S417 4' - 1 1/2"
7' - 7 1/2"

PERIMETER BASEMENT CANOPY BOLLARD -


C11-1
5' - 8"

T.O. WALL 1 OPEN

2' - 0"
ELEV. VARIES WALL BELOW - TYPICAL SEE 6/S703 - TYP. T.O. WALL EL. VARIES KEY PLAN

11 11 CITY OF AUSTIN
TRANSITION IN
6"
1' - 6"
2' - 0"

2' - 0"
10 WALL THICKNESS METAL GRATE AT SLAB
9 5
OPENING - SEE ARCH'L
S213 T.O.S.C. EL. = 450' - 4 3/8" S214
S213 OWNER
11' - 6" (TYP @ SOUTH PERIMETER)
4' - 4 7/8"
NEW CENTRAL LIBRARY
10' - 7" 24' - 1 1/4" 5' - 7" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 12' - 3" 1' - 9 1/2" CIP ID#7235.001
2' - 3" W. CESAR CHAVEZ BLVD.
12' - 5" 29' - 9" 29' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 13' - 0 1/2"
PROJECT
AUSTIN, TX
2' - 6" 3' - 3 1/2"
10' - 1" 197' - 10 5/8"

ENLARGED LEVEL 1 - SOUTH


DRAWING TITLE
A A.3 B C D E F G Y4 H
CIP ID#7235.001

SEE SHEET S103 FOR PLAN NOTES

SCALE
1/8" = 1'-0" DATE
08/16/13

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

Author Checker
LEVEL 1 ENLARGED PLAN - SOUTH DRAWN CHECKED
NEW CENTRAL LIBRARY

1 SCALE 1/8" = 1'-0" PACKAGE 2 CONSTRUCTION DOCUMENTS

S103.2
9/26/2013 8:30:44 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
PLAN NOTES:
1. REFER TO THE SLAB EDGE PLANS IN THE A120 SERIES ARCHITECTURAL
DRAWINGS FOR SLAB EDGE DIMENSIONS.
2. SHADED AND HATCHED REGIONS INDICATE AREAS TO RECEIVE A CONCRETE
TOPPING. REFER TO S506 FOR CONCRETE TOPPING DETAILS. REFER TO SLAB
EDGE PLANS FOR CONCRETE TOPPING EXTENTS AND ELEVATIONS.
3. REFER TO THE S300 SERIES SHEETS FOR CONCRETE COLUMN & SHEAR WALL
SCHEDULES AND TYPICAL DETAILS.
4. REFER TO THE S500 SERIES SHEETS FOR CONCRETE BEAM, JOIST, & SLAB
SCHEDULES AND TYPICAL DETAILS.
5. REFER TO THE SLAB EDGE PLANS FOR EXTENTS OF ARCHITECTURALLY
EXPOSED CONCRETE. REFER TO THE SPECIFICATIONS FOR REQUIREMENTS.
6. REFER TO THE ARCHITECTURAL DRAWINGS FOR RAISED CONCRETE CURB
EXTENTS AND ELEVATION.

Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

PROJECT CONSULTANT

A A.3 B C D E F F.1 G J
12'-5" 29'-9" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"
Y1

Y1.7
X1 Y2
Y3
1 1
Luke David Nelson No. 98643

14'-6"

14'-6"
Datum Reg No. F-2819

2 2
X2
X1

30'-0"

30'-0"
1/4"
32'-2
3 3
X3.1

26'-0"

26'-0"
X2

"
27'-6
4 4

30'-0"
X3

30'-0"
NO. DATE DESCRIPTION
REVISIONS

X3.1
Y0
5 F.1 Y3 5
13'-0"

13'-0"
6 6
Y1.7 J
30'-0"

30'-0"
PG

18/S513
7 7 KEY PLAN

CITY OF AUSTIN
30'-0"

30'-0"
P2 OWNER
Z
NEW CENTRAL LIBRARY
8 8 CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
14'-0"

14'-0"
K AUSTIN, TX
P3 PROJECT

9 Z 9
P4

16'-0"
LEVEL 2 - COMPOSITE PLAN
31'-0"

10 K 10 DRAWING TITLE
CIP ID#7235.001

15'-0"
Y0 P5
N
11 11
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

12'-5" 29'-9" 29'-6" 30'-0" 30'-0"


PA30'-0"PB PC30'-0"PD PG

A A.3 B C D E F G SCALE
As indicated DATE
08/16/2013

JOB NUMBER
3860

TP LN
LEVEL 2 COMPOSITE FRAMING PLAN DRAWN CHECKED
NEW CENTRAL LIBRARY

1 SCALE 1/16" = 1'-0"


PACKAGE 2 CONSTRUCTION DOCUMENTS

S104
1/20/2014 11:02:54 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
A A.3 B C D E F F.1 G J
12'-5" 29'-9" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"

22'-4 1/2" 2'-0"

CONCRETE PAD FOR PERSONNEL HOIST


Y1

Lake|Flato
Y1.7 311 Third Street, San Antonio , Texas 78205
LOUVER OPENING,
SEE ARCH'L
X1 T:210.227.3335
www.LakeFlato.com

9
Y2 Shepley Bulfinch Richardson & Abbott
6 SIM. 11 1 2 Seaport Lane, Boston, Massachusetts 02210
1 2 1

72
S511 13 2 T:617.423.1700

17.50°
19 S511 S511
SIM. 1

.50
S511 S514 TYP. www.ShepleyBulfinch.com
S512 S514

°
S511 S513
2'-6"

B333
1 1

6'-11"
53" PAN

B143
B212
2'-10"
10 J21 43" PAN J22 43" PAN
S511
P6

S3
14'-6"

14'-6"
3'-10 1/2" 30" PAN 30" PAN

B331

B334
PROJECT CONSULTANT
B213
T.O.S.C. EL. = 463'-4"
S3A

1'-7" B139 B140 S4

8'-1"
14
S511 B56 B57 6'-4" 8'-6"
J21 20" PAN J22 20" PAN Y3
2 53" PAN C37 53" PAN 2
J21 J22 PROJECT CONSULTANT
5 17
S511 3 1/
S511 2"
B335
4 ?

B219

B221
J14

J14

J28

J28

J28

J28

J14

J14
J9

J9
T.O.S.C. EL. = 465'-0"
S511 X2 J21 J22

X1

B328
LOUVER 7

43" PAN
CONC. TOP'G OVER
OPENING S511
W.P.'G MEMBRANE

B143
30'-0"

30'-0"
J21 J22
S2

IN DOCK AREA S5

30" PAN

B330

7
B33
2'-6" J21 J22

30" PAN
1
B341
T.O.S.C. EL. = 465'-0"

B301
16

1/4"
T.O.S.C. EL. = 461'-0"
S511

32'-2
J11

J11

B17
J11

J11

J11

2'-0"
B56 B57 B184 B185 B302 B303 B304 B305 B306 B307
3 3 Luke David Nelson No. 98643
Datum Reg No. F-2819

5'-6"
3

J24

B296
S511
B153
X3.1 B263

15" PAN
W8X

J15
1 10 1
8

B155

B327
11'-0"

J27

B264
J8
18/S504 S512 7
X2

B141
J16

J29

J29

J29

J29

J29

J29
26'-0"

26'-0"
B340

B218
B16
J23

J23

J17

J17

J25

J16
TYP. S512
S1

TEMPORARY OPENING FOR


CONSTRUCTION CRANE S5
W8X

6
B296 B144

B33
10 B153 3
B198
1'-6" 11'-0" S801

B329
53" PAN

30" PAN
1 2

J11
1
S511 S511 B199

B192

"
27'-6
B350 B351 B184 B185 B278 B279 B280 G/S602
4 4
1'-8"

W16X57 B200
STRINGER, TYP.
B332
15 2
14'-7 1/4" 20
S512

B191
S11 S703

B326
J23

1'-3"
GARAGE RAMP,
4'-6"

43" PAN
SEE S221 9 2 11/15/2013 ADDENDUM #5

1'-3" S513 X3 1
NO.
09/26/2013
DATE
ADDENDUM #2
DESCRIPTION
30'-0"

30'-0"
B217

B206
5 REVISIONS
B15

J13

J13

J13

J25

J25
J7

J7

S512 B205 X3.1


B339

18

30" PAN
S511

B205
14

B259

B193
S512

PAN

J11
43"
3#9 T&B (HOOK EA.
Y2
W12
X19
5 B269 B270 B271 B272 B273 END) W/ #3 STIR. @ Y3 5
B267 6" IN 12" WIDE BEAM
1

X19
43" PAN

3" M T.O.S. EL. = 464'-2"


ET

W12
DEC AL
B325

B310

SIM.
J11

J11

J11

J11

J11

J11
13'-0"

13'-0"
1
B216

B260
K 20
B14
J11

J11

J41

J25
12
J6

J6

J6

J6

J6

J6

J6

J6

B227
S511 S603
B268

X19
S11
3'-6" 6'-11"

B262
1

W12
3
G/S602, TYP. 1
B288 B289 B290 B291 B292 B294 S611
6 B293 MATCHLINE:1/S104.2
6 KEY PLAN

CITY OF AUSTIN
J23 30" PAN

1
6.1 J11
6.1

B194
1 1 B195
2'-6"

B259

B226

B261
53" PAN

S4
1

S10

S4
B215
J20

J20

J20

J23

J23

B194
30" PAN

30" PAN

B347
J23

J23

B349
6.3 1
6.3 OWNER
B222 B223 B223 B224
J23

Y1.7 NEW CENTRAL LIBRARY


CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
20 AUSTIN, TX
A A.3 B C D E
S514 F F.1 G J PROJECT

ENLARGED LEVEL 2 - NORTH


LEVEL 2 FRAMING PLAN
1 DRAWING TITLE
CIP ID#7235.001

SCALE 1/8" = 1'-0"

N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

SCALE
1/8" = 1'-0" DATE
08/16/2013

JOB NUMBER
3860

DRAWN
TP CHECKED
LN
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S104.1
1/20/2014 11:02:56 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
E

P5

5.50°

8 1/2"
10

Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PORCH COLUMN
2 SCALE 1/2" = 1'-0"

PROJECT CONSULTANT

14
A A.3 S512
B C D E F Y1.7 G PROJECT CONSULTANT

Y0

B259

B193
J11
3#9 T&B (HOOK EA. W12
B269 B270 B271 B272 B273 END) W/ #3 STIR. @ X19
5 6" IN 12" WIDE BEAM 5
B267
1

X19
43" PAN
3" M T.O.S. EL. = 464'-2"
ET

W12
DEC AL
B325

B310

SIM.
J11

J11

J11

J11

J11

J11

1
13'-0"

13'-0"
B216

B260
K 20

B14
J11

J11

J41

J25
12

J6

J6

J6

J6

J6

J6

J6

J6

B227
S603
S511 B268

X19
S11
3'-6" 6'-11"

B262
1

W12
3 1
G/S602, TYP. MATCHLINE:1/S104.1
B288 B289 B290 B291 B292 B294 S611
6 B293
6 Luke David Nelson No. 98643
Datum Reg No. F-2819

J23 30" PAN


1
Y1.7

J11

B194
1 1 B195
2'-6"
53" PAN

B259

B226

B261
S4
1

S10

S4
B215
J20

J20

J20

J23

J23
30" PAN B194

30" PAN

B347
J23

J23

B349
1
1 B222 B223 B223 B224
B309

J23
B324

30" PAN

B314
30'-0"

30'-0"
B252

B276
J25

J25

J25

J25

J25

J25

20

25
B2
S511 B3
J18

46

2'-7 3/4"
6
S513 1 PG
B348

18/S513
B298 B299 B300
7 7
B315
S11

72
.50
53" PAN

T.O.S.C. EL. = 465'-0"


B297
B323

B316
12 1 09/26/2013 ADDENDUM #2
P1
53" PAN

S511 NO. DATE DESCRIPTION


J15

J15

J15

J15

J15

J15

REVISIONS
B318
30'-0"

10'-0"

30'-0"
B311

1
B313

1
B317

B214
J19

J19

J19
B308

S104.3

B312
P2
J29

B319
B32
0
Z

10'-0"
12
SIM.
S7

S511
S7

1
S6

8 8
B321 B322 LINE OF HANGING MASONRY &
ROOF SUPPORT. SEE 20/S611. 1

10'-0"
14'-0"

14'-0"
15
S511
P3 KEY PLAN

9 Z 9 CITY OF AUSTIN

10'-0"
20
S512
20
P4 OWNER
16'-0"

16'-0"
S514

NEW CENTRAL LIBRARY

8'-3"

10'-0"
CIP ID#7235.001
P5 W. CESAR CHAVEZ BLVD.
AUSTIN, TX
10 10 PROJECT

Y0 2
S104.2 ENLARGED LEVEL 2 - SOUTH
LOCATION OF TEMPORARY P5 DRAWING TITLE
CONSTRUCTION CRANE.
CIP ID#7235.001

N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

PA PB PC PD PG

SCALE
As indicated DATE
08/16/2013
12'-5" 29'-9" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0"
JOB NUMBER
3860
A A.3 B C D E F G TP LN
DRAWN CHECKED
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

1
LEVEL 2 FRAMING PLAN S104.2
1/20/2014 11:02:58 AM

SCALE 1/8" = 1'-0"

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

F
G
PROJECT CONSULTANT

1 Luke David Nelson No. 98643


Datum Reg No. F-2819

2#6 X 40'-0" MID-


DEPTH OF SLAB

18/S513
B286
T.O.S.C. EL. = 471'-6"

6
S512 1 09/26/2013 ADDENDUM #2
NO. DATE DESCRIPTION
REVISIONS

1'-7" 2'-2"

B285
KEY PLAN

CITY OF AUSTIN

OWNER

NEW CENTRAL LIBRARY


CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
AUSTIN, TX
8 PROJECT

B284
1
1
2'-10" ENLARGED LEVEL 2 - SOUTH
1 HSS5X5X1/4 6" 6"
DRAWING TITLE
S611 DIAGONAL BRACING
CIP ID#7235.001

HSS5X5X1/4 TYP.
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

HSS5X5X1/4

HSS5X5X1/4 TYP.
4
S611

HSS5X5X1/4
9 HSS5X5X1/4 9 SCALE
1/4" = 1'-0" DATE
08/16/2013
1 3860
JOB NUMBER

12'-0" 20 10
DRAWN
TP CHECKED
LN
NEW CENTRAL LIBRARY

S611 S611
3" STEEL DECK ON STEEL
F FRAMED CANOPY SUSPENDED PACKAGE 2 CONSTRUCTION DOCUMENTS
FROM LEVEL 3 STRUCTURE

S104.3
1/20/2014 11:03:00 AM

MIDLEVEL BEAM & EVENT FORUM ROOF


1 SCALE 1/4" = 1'-0"
DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
PLAN NOTES:
1. REFER TO THE SLAB EDGE PLANS IN THE A120 SERIES ARCHITECTURAL
DRAWINGS FOR SLAB EDGE DIMENSIONS.
2. SHADED AND HATCHED REGIONS INDICATE AREAS TO RECEIVE A CONCRETE
TOPPING. REFER TO S506 FOR CONCRETE TOPPING DETAILS. REFER TO SLAB
EDGE PLANS FOR CONCRETE TOPPING EXTENTS AND ELEVATIONS.
3. REFER TO THE S300 SERIES SHEETS FOR CONCRETE COLUMN & SHEAR WALL
SCHEDULES AND TYPICAL DETAILS.
4. REFER TO THE S500 SERIES SHEETS FOR CONCRETE BEAM, JOIST, & SLAB
SCHEDULES AND TYPICAL DETAILS.
5. REFER TO THE SLAB EDGE PLANS FOR EXTENTS OF ARCHITECTURALLY
EXPOSED CONCRETE. REFER TO THE SPECIFICATIONS FOR REQUIREMENTS.
6. REFER TO THE ARCHITECTURAL DRAWINGS FOR RAISED CONCRETE CURB
EXTENTS AND ELEVATION.

Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

PROJECT CONSULTANT

A B C D E F F.1 G J
42'-2" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"

Y1
Y1.6
Y1.7
Y1.8
X1 Y2
Y3
1 1
Luke David Nelson No. 98643

14'-6"

14'-6"
Datum Reg No. F-2819

2 2

X1

30'-0"

30'-0"
3 3

26'-0"

26'-0"
X2

4 4

30'-0"
X3

30'-0"
NO. DATE DESCRIPTION
REVISIONS
X3.1

5 F.1 Y3 5
13'-0"

13'-0"
6 6
J
30'-0"

30'-0"
PG

7 7 KEY PLAN

CITY OF AUSTIN
P1 P1
30'-0"

30'-0"
P2 OWNER
Z
NEW CENTRAL LIBRARY
8 8 CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
14'-0"

14'-0"
AUSTIN, TX
P3 PROJECT

9 Z 9
P4
16'-0"

16'-0"
LEVEL 3 - COMPOSITE PLAN

7/S701
10 K 10 DRAWING TITLE
CIP ID#7235.001

Y0 P5
N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

PA PB PC PD PG
42'-2" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0"

A B C D E F G SCALE
As indicated DATE
08/16/2013

JOB NUMBER
3860

DRAWN
TP CHECKED
LN
NEW CENTRAL LIBRARY

LEVEL 3 COMPOSITE FRAMING PLAN PACKAGE 2 CONSTRUCTION DOCUMENTS


1 SCALE 1/16" = 1'-0"

S105
1/20/2014 11:03:02 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
A A.3 B C D E F G J
12'-5" 29'-9" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"
10
S705

DIAGONAL STRUTS
Y1
METAL PANEL TO PERFORM PER 20/S705
AS STRUCTURAL DIAPHRAM DIAGONAL STRUTS
20 PER 20/S705
S705
HSS6X4X3/8 HSS6X4X3/8 HSS6X4X3/8 HSS6X4X3/8 HSS6X4X3/8

T)
Lake|Flato

T)
Y1.7

HSS6X4X3/8 (BENT)
T)
HSS6X4X3/8 (BENT)

HSS6X4X3/8 (BENT)
BEN
HSS6X4X3/8 (BENT)

HSS6X4X3/8 (BENT)

HSS6X4X3/8 (BENT)

HSS6X4X3/8 (BENT)

HSS6X4X3/8 (BENT)
EMBEDS FOR PERSONNEL HOIST 311 Third Street, San Antonio , Texas 78205

BEN

BEN
2-PL 3/4X12X12 W/4-3/4" DIA. X 8" H.S. X1 T:210.227.3335

3/8 (
3/8 (
www.LakeFlato.com

3/8 (
(LEVELS 3, 4, 5 & 6)
Y2

6X4X
6X4X

6X4X
TYP. TYP. @ Shepley Bulfinch Richardson & Abbott
@ STONE 2 Seaport Lane, Boston, Massachusetts 02210

HSS
12A TYP. OPENINGS 2

HSS
10

3/8

HSS
3 13 TYP. T:617.423.1700
S512 2
11/S705
/

4 7/8"

6X4X
S507 S512 @ STONE www.ShepleyBulfinch.com
S512 10 S513
HSS6X4X3/8 HSS6X4X3/8 HSS6X4X3/8 HSS6X4X3/8 HSS6X4X3/8
S507

HSS
HSS6X4X3/8
B92

1'-3 1/8"

B250
1 1

J31
B82 B83 B83 B84 W8X31 W8X31 W8X31
1'-0"

HSS
6X4X
3/8

B42
B107

SIM. B85 B93

J31
HSS8X8X1/2
14'-6"

14'-6"
18
12'-0"

PROJECT CONSULTANT

J31
S512

J31
T.O.S.C. EL. = 482'-0"

J31
2

2 S11 2
2'-6"

B94
PROJECT CONSULTANT
HSS8X8X1/2

B104

B211

B249
B29

B41
J14

J14

J28

J14

J14

J14

J14

J26

J17

J25

J25

J25
B7
J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9
12'-6"

18

30" PAN
S512
1 X1

53" PAN
30" PAN

43" PAN
S512

B43
30'-0"

30'-0"
2'-6"

53" PAN

B146
18
HSS8X8X1/2

2
S11 S702

B301
30" PAN
B17
J11

J11

J11

J11

J11
12'-6"

1/4"
32'-2
B44 B45 B46 B49 B50 B51 B52 B53
3 3 Luke David Nelson No. 98643
2'-6"

Datum Reg No. F-2819

5'-6"
J24

B296
HSS8X6X1/4 LSV, TYP.
HSS8X6X1/4 LSV, TYP.

53" PAN
B210
J16
B153

J16
X3.1
HSS8X8X1/2

B263

J15

B264
1
10'-6"

TYP., SIM.
30" PAN

18/S504 W8X

B48
10
B201
B106

11'-0"
@ STONE

B154
TYP.

J15
10

B248
X2

B40
J15

J32

J32

J32
S512
26'-0"

26'-0"
S507

B16
J17

J17

J17

J17

J25
B6
2'-6"

J8

J8

J8

J8

J8

J8

TEMPORARY OPENING FOR

B28

B145
CONSTRUCTION CRANE B144
10 B296 W8X 10
10 B153 SIM. B202
S706 11'-0" S513
HSS8X8X1/2

53" PAN
10'-6"

1'-6"

J11
SIM.
B203

"
9 10

27'-6
2'-0" S513 20 S507
B177 B178 B179 B281 TENSION TIES
4 S513 - 1/2" ROD 4
2'-6"

1
B204 DIAGONAL TENSION
STRUTS PER 20/S703
DASHED AREA TO REMAIN
HSS8X8X1/2

SHORED UNTIL AFTER FINAL

J25
STRESSING OF TRANSFER

B47
12'-6"

GIRDERS SIM. TAPERED TUBES PER 20/S703


9 2 11/15/2013 ADDENDUM #5
W16X57 STRINGER, TYP. S513
3" DECK, SEE X3 1 09/26/2013 ADDENDUM #2
B106

GEN. NOTES 9 NO. DATE DESCRIPTION


B15

B27
J40

J39

J39

J39
B5
J7

J7

J7

J7

J7

J7

J7

J7

J7

J7
30'-0"

30'-0"
S513 REVISIONS
X3.1
2'-6"

1
6
T.O.S.C. EL. = 482'-0" B274 S801

B247
METAL PANEL TO PERFORM
HSS8X8X1/2

AS STRUCTURAL DIAPHRAM
10'-11 3/4"

30" PAN
S8

B246
1 20
S703
1'-6 1/4"

B275

43" PAN

43" PAN
B58 B75
5 5

J12 30" PAN


20
11 3/4"

B88
J12

J12

J12
3" / 1 TAPERED TUBE
J7
13 5 1 3/8
S706 /8 2" " / 12 OUTRIGGERS PER 20/S703
" / 12 "
"

J12

J12

J12
43" PAN
13'-0"

13'-0"
B105

B91
B14
J41
B4
J6

J6

J6

J6

J6

J6

J6

J6

J6

E
10

TON
S507 8

@S
B58 B60 B60 B61 B62
6 @ STONE S507
MATCHLINE:1/S105.2
6 KEY PLAN

CITY OF AUSTIN

B194
B195
TENSION TIES -
B194 1/2" DIA. ROD
J23

J23

30" PAN

B245
19 OWNER

S702
NEW CENTRAL LIBRARY
Y1.7 CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
PROJECT
AUSTIN, TX
20
A A.3 B C D E
S514 F G J
ENLARGED LEVEL 3 - NORTH
LEVEL 3 FRAMING - NORTH
1 SCALE 1/8" = 1'-0" DRAWING TITLE
CIP ID#7235.001

N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

SCALE
1/8" = 1'-0" DATE
08/16/2013

JOB NUMBER
3860

DRAWN
TP CHECKED
LN
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S105.1
1/20/2014 11:03:05 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

A B C D E F Y1.7 G PROJECT CONSULTANT

Y0 B275

43" PAN

43" PAN
B58 B75
5 5

J12 30" PAN


20

B88
J12

J12

J12
3" / 1

J7
13 5 1 3/8
S706 /8 2" " / 12
" / 12 "
"

J12

J12

J12
43" PAN
13'-0"

13'-0"
B105

B91
B14
J41
B4
J6

J6

J6

J6

J6

J6

J6

J6

J6

E
10

TON
S507 8
MATCHLINE:1/S105.1

@S
B58 B60 B60 B61 B62
6 @ STONE S507
6 Luke David Nelson No. 98643
6.1 Datum Reg No. F-2819
6.1 Y1.7

B194
B195
TENSION TIES -
B194 1/2" DIA. ROD
J23

J23

30" PAN
B3

B245
6.3 TYP. 19
6.3
12A 1
S702
B252
@ SCRIM 1
S512
30" PAN
30'-0"

30'-0"
B276
B104

J5

J5

J5

J5

J5

J5

B13

B26
B2

J40

J38

J38

J38
J5

J7

J7

J7

J7

J7

J7

J7

J7
51
PG
1
30" PAN

6 B194

30" PAN

30" PAN

30" PAN

B244
S513 1
SIM. 2#6 X 40'-0" MID-
C27 C27

J13

J13
DEPTH OF SLAB
10" 7 5/8"

B354
16/S701
/
2'-7 3/8"
2'-5"
4'-5"

MC4x13.8
B71 B72 B73 B74 B74 B75
7 7
3'-2"

B90
TRANSFER GIRDER

TRANSFER GIRDER
B87

10'-0"
2
3 SP. @ 2'-8" 3/4" DIA. STEEL
B296 X-ROD BRACING
2 11/15/2013 ADDENDUM #5
1 09/26/2013 ADDENDUM #2
10 T.O.S.C. EL. = 482'-0" P1 NO. DATE DESCRIPTION
20 REVISIONS
S507
S701
30'-0"

30'-0"
10'-0"
B296 19

B243
@ STONE

B25

J4

J4

J4

J4

J4

J4
B12

J4

J4
J4

J4

J4

J4

J4

J4
S507

B353
2
B103

B2
J2

J2

J2

J2

J2

J2

J3

J3

J3

J4

@ WINDOWS

30" PAN
30" PAN

53" PAN

53" PAN

53" PAN

53" PAN
66" PAN TYP. U.N.O.

P2

W12X35 TYP., UNO


B188
30" PAN

SEE ARCH'L
FOR CURB
Z

10'-0"
1
S11

B80 B81 W12X35 TYP.


8 8
30" PAN
B187

B79
LINE OF HANGING 20
B79 MASONRY &

B89

B242
J1

J1

J1

10'-0"
MC4x13.8

MC4x13.8

MC4x13.8

MC4x13.8

MC4x13.8
ROOF SUPPORT S611 IPE WOOD
B78 DECKING
14'-0"

14'-0"
B86

J1

J1

J1
B77

B352
K P3
J1

J1

J1

J1
B24

1
B76 STEEL HANGERS BELOW @ KEY PLAN
B11

J1

J1

J1

J1

13 8 MID-LEVEL CONCRETE BEAM HSS8X4X5/8 CONT.


9 Z TYP.
1
BETWEEN LEVEL 3-5 9 CITY OF AUSTIN

10'-0"
S513 S611
B1

J1

J1

J1

J1

1 11
B186

B102

S11 S701 1
J1

J1

J1

J1

J1

J1

MC4x13.8
19
S507 MC4x13.8 P4 OWNER
16'-0"

16'-0"
1 19
MC4x13.8
@ WINDOWS

W12SP
5/S701
/ , TYP.
NEW CENTRAL LIBRARY

5 SP. @ 2'-9"
19 S507 1 MC4x13.8

8'-3"
W12X35 TYP.
HSS8X4X5/8

10'-0"
S507
13/S701
/ , TYP. @ WINDOWS MC4x13.8 12
CIP ID#7235.001
@ WINDOWS W. CESAR CHAVEZ BLVD.
S701
20 @ SCRIM MC4x13.8
K AUSTIN, TX

7/S701
10 LOCATION OF TEMPORARY S702 MC4x13.8 10 PROJECT

W12SP
13
CONSTRUCTION CRANE. MC4x13.8
S513 W12X35 TYP
.
DIAGONAL TENSION 2 MC4x13.8
Y0 STRUTS PER 20/S704 S104.2 ENLARGED LEVEL 3 - SOUTH
3/4" DIA. STEEL 20
DIAGONAL TENSION
STRUTS PER 20/S704
X-ROD BRACING S701
P5
IPE WOOD DRAWING TITLE
CIP ID#7235.001

DECKING
1 & 2/S704 BOTTOM OF THIS COLUMN IS FLUSH
1 & 2/S704
W/ BOTTOM OF 12" PERIMETER BEAMS

TAPERED SPINE N
TUBE PER 20/S704
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

METAL PANEL TO PERFORM 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 12'-3"
AS STRUCTURAL DIAPHRAM
PA PB PC PD PG

TAPERED TUBE 1/8" = 1'-0" 08/16/2013


42'-2" 29'-6" PER 20/S704 30'-0" 30'-0" 30'-0" 30'-0"
SCALE DATE

JOB NUMBER
3860
A B 20 C D E F G TP LN
S704 DRAWN CHECKED
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

1
LEVEL 3 FRAMING - SOUTH
S105.2
1/20/2014 11:03:07 AM

SCALE 1/8" = 1'-0"

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
PLAN NOTES:
1. REFER TO THE SLAB EDGE PLANS IN THE A120 SERIES ARCHITECTURAL
DRAWINGS FOR SLAB EDGE DIMENSIONS.
2. SHADED AND HATCHED REGIONS INDICATE AREAS TO RECEIVE A CONCRETE
TOPPING. REFER TO S506 FOR CONCRETE TOPPING DETAILS. REFER TO SLAB
EDGE PLANS FOR CONCRETE TOPPING EXTENTS AND ELEVATIONS.
3. REFER TO THE S300 SERIES SHEETS FOR CONCRETE COLUMN & SHEAR WALL
SCHEDULES AND TYPICAL DETAILS.
4. REFER TO THE S500 SERIES SHEETS FOR CONCRETE BEAM, JOIST, & SLAB
SCHEDULES AND TYPICAL DETAILS.
5. REFER TO THE SLAB EDGE PLANS FOR EXTENTS OF ARCHITECTURALLY
EXPOSED CONCRETE. REFER TO THE SPECIFICATIONS FOR REQUIREMENTS.
6. REFER TO THE ARCHITECTURAL DRAWINGS FOR RAISED CONCRETE CURB
EXTENTS AND ELEVATION.

Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

PROJECT CONSULTANT

A A.3 B C D E FF.1 G H
A A.3 B C D E Y1 F F.1 G JJ Y2
12'-5" 29'-9" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"
Y1 Y1.7Y1.8
Y3
Y1.6
Y1.7
X1 Y2
Y3
1 1 1

Luke David Nelson No. 98643

14'-6"

14'-6"
Datum Reg No. F-2819

2 2 2

X1

30'-0"

30'-0"
1/4"
FD
FD

32'-2
X1
3 3 3

X3.1

26'-0"

26'-0"
X2
A.3

"
27'-6
4 4 4
X2.6 X2

30'-0"
X3

30'-0"
NO. DATE DESCRIPTION
REVISIONS
Y1

02
03
X3.1

3/S8
3/S8
Y0 X3
5 F.1 Y3 5 5
X3.1
13'-0"

13'-0"
6 6 6

FD
Y1.7 J
6.3
30'-0"

30'-0"
FD

7 7 7
KEY PLAN

CITY OF AUSTIN
P1 P1
30'-0"

30'-0"
P2 P2 OWNER
Z
NEW CENTRAL LIBRARY
8 8 8
CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
14'-0"

14'-0"
K AUSTIN, TX
P3 P3 PROJECT

9 ZZ 9 9

P4 P4
16'-0"

16'-0"
LEVEL 4 - COMPOSITE PLAN

10K K 10 10 DRAWING TITLE


CIP ID#7235.001

Y0 P5 P5
11
N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

PA PB PC PD PG
42'-2" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0"

PA PB PC PD PG
PE
Y4
A B C D E F G SCALE
As indicated DATE
08/16/2013

JOB NUMBER
3860

DRAWN
TP CHECKED
LN
NEW CENTRAL LIBRARY

LEVEL 4 COMPOSITE FRAMING PLAN


1 SCALE 1/16" = 1'-0"
PACKAGE 2 CONSTRUCTION DOCUMENTS

S106
1/20/2014 11:03:14 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
A A.3 B C D E F G J
12'-5" 29'-9" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"
10
S705
Y1

20
S705

Lake|Flato
Y1.7 311 Third Street, San Antonio , Texas 78205
X1 T:210.227.3335
www.LakeFlato.com
Y2 Shepley Bulfinch Richardson & Abbott
SIM. @ STONE 2 Seaport Lane, Boston, Massachusetts 02210
12A 10 11A 12A T:617.423.1700
S512 12A www.ShepleyBulfinch.com
S507 S512 S512
S512 @ STONE
10
S507
Y3
B98 10
1 B95 B96 B96 B97 B96 S512 1

B93
B113
14'-6"

14'-6"
PROJECT CONSULTANT

2 B99 2
PROJECT CONSULTANT

B36
B23

B34

J28

J14

J14
J14

J14

J14

J14
J14
B7

J9

J9

J9
J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9
30" PAN

X1

B38

J14

J14
J9

J9

J9

J9

J9

J9
30'-0"

30'-0"
B110

T.O.S.C. EL. = 499'-0"

15" PAN

53" PAN
18

B148
S702

1/4"
TEMPORARY OPENING FOR

32'-2
CONSTRUCTION CRANE

B44 B45 B46 B49 B50 B51 B52 B54 10 SIM.


3 S512
3 Luke David Nelson No. 98643
Datum Reg No. F-2819

5'-6"
J24

B296
B153

B35
J15

J16

J16

B264
1 X3.1 B263

1/2"
30" PAN

J15
B22
J15
W8X

B37
1'-8"

J15

J15

15" PAN J15

J15
18/S504 10 8

1'-9
B147 GIRDER
TYP.

11'-0"
10 S512 B201
X2

B154
26'-0"

26'-0"
S507
B112

SIM.

J15
B10

B33
J15

J15

J35

J35
J8

J8

J8

J8

J8

J15

J15
9 12A
@ STONE

ER
S513 S512

NSF
B296 W8X B144
10 B153 B202

3/8"
TRA
11'-0" 10 @ STONE

B343

17'-7
53" PAN
8 S507
1'-6" SIM.

J36
S513 SIM.
9
B207 12A
S513
B180 B181 B182 B282 S512
4 4
6 1
C41
S801 1 B208 X2.6

5/8"
20
B342

9'-10
30" PAN

30" PAN

43" PAN

30" PAN

S703
6
9 S801 OPEN
SIM.
S513 9
X3 1 09/26/2013 ADDENDUM #2

1'-3"
S513 NO. DATE DESCRIPTION
30'-0"

30'-0"
B112

B234

B233

B254

REVISIONS
J7

J7

J7

J7

J7

J7

3 OPEN Y1 X3.1
TYP. AT S706
W16X57 STRINGER, TYP.

02
CANOPY

3/S8
B235
20" PAN
J36
J36

1'-8" 15
S803
9

5
B69 B70 S513 Y3 5
B111

SIM. 9
30" PAN

43" PAN

53" PAN

12A
13'-0"

13'-0"
B253

S513
J11

J11

J11
B9
J6

J6

J6

J6

J6

J6

B21

S512
15
S802

E
TON
8
B58 B59 B63 B64 B65

@S
6 S507
MATCHLINE:1/S106.2
6 KEY PLAN
B197
Y1.7 CITY OF AUSTIN

B196
J23

B344
J23

B196
30" PAN
30" PAN

19 OWNER

S702
NEW CENTRAL LIBRARY
CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
PROJECT
AUSTIN, TX

A A.3 B C D E F G J
ENLARGED LEVEL 4 - NORTH
LEVEL 4 FRAMING - NORTH
1 SCALE 1/8" = 1'-0"
DRAWING TITLE
CIP ID#7235.001

N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

SCALE
1/8" = 1'-0" DATE
08/16/2013

JOB NUMBER
3860

DRAWN
TP CHECKED
LN
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S106.1
1/20/2014 11:03:17 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

A B C D E F Y1.7 G PROJECT CONSULTANT

Y0
B69 B70
5 5
B111

SIM. 9
30" PAN

43" PAN

53" PAN
12A
13'-0"

13'-0"
B253
S513
J11

J11

J11
B9
J6

J6

J6

J6

J6

J6

B21
S512

E
TON
8
B58 B59 B63 B64 B65 MATCHLINE:1/S106.1

@S
6 S507
6 Luke David Nelson No. 98643
B197
Datum Reg No. F-2819
Y1.7

B196
J23

B344
J23
B8

30" PAN B196


30" PAN

@ STONE 19
10 1
B252
S702
@ SCRIM 1
30" PAN

S507
30'-0"

30'-0"
B276

B32
B110

B20

B32

B32
J17

J37

J37

J37

J37

J13

J13

J13

J13

J13

J13

J13

J13
J5

J5

J5

J5

J5

J5

B2
51
PG
1

J13

J13

J13
B196
6
30" PAN

30" PAN

30" PAN

30" PAN
1
S513 2#6 X 40'-0" MID-

30" PAN
SIM.

B239
DEPTH OF SLAB

J13
10'-10"

B71 MC4x13.8
B72 B73 B74 B74 B75
7 7

10'-0"
2 3 SP. @ 2'-8" 3/4" DIA. STEEL
B296 X-ROD BRACING

30" PAN

30" PAN

30" PAN
30" PAN 2 11/15/2013 ADDENDUM #5
1 09/26/2013 ADDENDUM #2
P1

W12X35 TYP., UNO


NO. DATE DESCRIPTION
SIM. 20 REVISIONS
12A
S701
S512
30'-0"

30'-0"
10'-0"
B296 19

B31
B31

B31
J4

J4

J4

J4

J4

J4

J4

J4
J4

J4

J4

J4
B19

J4

J4

J4

J4
2 S507
30" PAN

30" PAN

B237
T.O.S.C. EL. = 499'-0" @ WINDOWS
1
P2
B109

B188
SEE ARCH'L
FOR CURB
Z

10'-0"
B2
J2

J2

J3

J3

J3
J2

J2

J2

J4
J2

1
S11

B80 B81
8 B79
8
B187

B79 IPE WOOD

30" PAN

MC4x13.8

MC4x13.8

MC4x13.8

MC4x13.8

MC4x13.8
30" PAN

J1 30" PAN

10'-0"
DECKING
B78
14'-0"

14'-0"
30" PAN

B77

B236
B30

B30
J1

J1

J1

J1

J1

J1

J1
B30

J1

J1

J1
P3
J1
30" PAN

B76 W12X35 TYP. KEY PLAN

HSS8X4X5/8 CONT.
9 Z 13
TYP. BETWEEN LEVEL 3-5 9 CITY OF AUSTIN

10'-0"
J1

J1

J1

J1

S513
B18
J1
B1

J1

J1

J1

11
B186

B108

MC4x13.8 S701 1
J1

J1

J1

30" PAN J1

J1

J1

19 1
S507 S11 MC4x13.8 P4 OWNER
16'-0"

16'-0"
19
MC4x13.8
@ WINDOWS

W12SP
5/S701
/ , TYP.
NEW CENTRAL LIBRARY

W12X35 TYP.
5 SP. @ 2'-9"
19 S507 MC4x13.8

8'-3"

10'-0"
S507
13/S701
/ , TYP. @ WINDOWS MC4x13.8 12 CIP ID#7235.001
@ WINDOWS S701 W. CESAR CHAVEZ BLVD.
20 MC4x13.8 AUSTIN, TX

7/S701
10 K S702 MC4x13.8 10 PROJECT

W12SP
@ SCRIM MC4x13.8
HSS8X4X5/8 W12X35 TYP
1 .
2 MC4x13.8
Y0 S104.2 ENLARGED LEVEL 4 - SOUTH
3/4" DIA. STEEL 20
LOCATION OF TEMPORARY X-ROD BRACING S701
P5 DRAWING TITLE
CONSTRUCTION CRANE. IPE WOOD
CIP ID#7235.001

DECKING

N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 12'-3"

PA PB PC PD PG

SCALE
1/8" = 1'-0" DATE
08/16/2013
42'-2" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0"
JOB NUMBER
3860
A B 20 C D E F G TP LN
S704 DRAWN CHECKED
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

1
LEVEL 4 FRAMING - SOUTH
S106.2
1/20/2014 11:03:19 AM

SCALE 1/8" = 1'-0"

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
PLAN NOTES:
1. REFER TO THE SLAB EDGE PLANS IN THE A120 SERIES ARCHITECTURAL
DRAWINGS FOR SLAB EDGE DIMENSIONS.
2. SHADED AND HATCHED REGIONS INDICATE AREAS TO RECEIVE A CONCRETE
TOPPING. REFER TO S506 FOR CONCRETE TOPPING DETAILS. REFER TO SLAB
EDGE PLANS FOR CONCRETE TOPPING EXTENTS AND ELEVATIONS.
3. REFER TO THE S300 SERIES SHEETS FOR CONCRETE COLUMN & SHEAR WALL
SCHEDULES AND TYPICAL DETAILS.
4. REFER TO THE S500 SERIES SHEETS FOR CONCRETE BEAM, JOIST, & SLAB
SCHEDULES AND TYPICAL DETAILS.
5. REFER TO THE SLAB EDGE PLANS FOR EXTENTS OF ARCHITECTURALLY
EXPOSED CONCRETE. REFER TO THE SPECIFICATIONS FOR REQUIREMENTS.
6. REFER TO THE ARCHITECTURAL DRAWINGS FOR RAISED CONCRETE CURB
EXTENTS AND ELEVATION.

Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

PROJECT CONSULTANT

A A.3 B C D E F F.1 G J
12'-5" 29'-9" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"
Y1

Y1.7
X1 84'-3 Y2
" Luke David Nelson No. 98643
Datum Reg No. F-2819
Y3
1 1

14'-6"

14'-6"
2 2
X2
X1

30'-0"

30'-0"
A.3

1/4"
32'-2
3 3
X3.1

26'-0"

26'-0"
X2

"
27'-6
NO. DATE DESCRIPTION
4 4 REVISIONS
X2.6

X3
30'-0"

30'-0"
X3.1
Y0
5 F.1 Y3 5
13'-0"

13'-0"
6 6
Y1.7 J
30'-0"

30'-0"
KEY PLAN

CITY OF AUSTIN

7 7
OWNER

P1 NEW CENTRAL LIBRARY


30'-0"

30'-0"
CIP ID#7235.001
P2 W. CESAR CHAVEZ BLVD.
Z PROJECT
AUSTIN, TX

8 8
14'-0"

14'-0"
LEVEL 5 - COMPOSITE PLAN
K P3
9 Z 9 DRAWING TITLE
CIP ID#7235.001

P4
16'-0"

16'-0"
N
10 K 10
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

Y0 P5

SCALE
As indicated DATE
08/16/2013
PA PB PC PD PG 3860
42'-2" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" JOB NUMBER

DRAWN
TP CHECKED
LN
A B C D E F G
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

LEVEL 5 COMPOSITE FRAMING PLAN


1 SCALE 1/16" = 1'-0" S107
1/20/2014 11:03:22 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
A A.3 B C D E F F.1 G J
12'-5" 29'-9" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"

Y1

Y1.6
Lake|Flato
Y1.7 311 Third Street, San Antonio , Texas 78205
X1 T:210.227.3335
www.LakeFlato.com
Y2 Shepley Bulfinch Richardson & Abbott
SIM. SIM. SIM. 18
2 Seaport Lane, Boston, Massachusetts 02210
12A 10 12 10 12 S611 T:617.423.1700
S512 S507 12A S507
S512 S512 www.ShepleyBulfinch.com
S512 10 SIM.

1/4
@ STONE
S507 Y3

7X7X
T.O.S. EL. = 510'-3"
1'-8"

1 1

1/4
HSS
B95 B83 B83 B129 B83

7X7X
B130
HSS

1/4
HSS 7X4X
7X7X 1/4 L

7X7X
1/4 T 18

HSS
SV 45
B131 YP. .0

1/4
S611 0°

HSS

7X7X
14'-6"

14'-6"
B120

1/4
PROJECT CONSULTANT

HSS

2'-0
7X7X

1/4
12A

"
7X7X
HSS
S512 SH
1/2 L

HSS
X7X
2 B132 HSS9 2
SH
PROJECT CONSULTANT

1/2L
X7X
SS9
H

B23

B34

B36
J14

J14

J28

J14

J14

J14

J14
B7
J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

B39
HSS
7X7X
1/4
30" PAN

30" PAN

30" PAN

30" PAN
13 X1

SV
B241
15" PAN
S611
30'-0"

30'-0"
B119

1/4 L
10

7X4X
S507
18 @ SCRIM

HSS
@ STONE HSS

B150
7X7X S702
1/4

1/4"
TEMPORARY OPENING FOR
CONSTRUCTION CRANE HSS

32'-2
7X7X
1/4
B44 B45 B46 B49 B50 B51 B55
3 3 Luke David Nelson No. 98643
Datum Reg No. F-2819

5'-6"
HSS

J24

B296
7X7X

J15
1/4

J16

J16
B35
B153 HSS
X3.1

B264
B263

J15
1 7X7X

15" PAN
1/4
18/S504 W8X
TYP. 10

J15
11'-0"
8
B201 @ STONE

B154
SIM. 10

B240
J15

J15
J15

J15
S512
X2
26'-0"

26'-0"
B345
10
B118

23'-2

B22
J35

J15

J15

J15

B33
B6
J8

J8

J8

J8

J8

J8

B149
3/8" S507
S513
30" PAN

B296 W8X
10 B153 8'-10 B202 B144
12 "

3/8"
11'-0"

53" PAN
S512

J36
1'-6"

17'-7
8
S11
9 S513 B209
2 S513
B180 B183 B182 B283
4 4

2'-5 1/2"
B204
X2.6

5/8"
9 20
S703

9'-10
S513 15
10

1'-3"
T.O.S.C. EL. = 516'-0" S513
S507 2 11/15/2013 ADDENDUM #5
1 1 09/26/2013 ADDENDUM #2
W16X57 STRINGER, TYP. @ STONE
X3
B258

NO. DATE DESCRIPTION


30'-0"

30'-0"
B117

REVISIONS
B5
J7

J7

J7

J7

J7

J7

SIM.
11A
6 Y1 X3.1
S801
S512
30" PAN

15
S804

9 SIM.
S513
B255
SLIDE BEARING SUPPORT
Y2
B69 B70 TYP. AT BRIDGES Y3
43" PAN

30" PAN

5 6
5
S801
1
B116

30" PAN

43" PAN
13'-0"

13'-0"
B257

B21
J11

J42

J11

J11

9
B4
J6

J6

J6

J6

J6

J6

B256
30" PAN

S513

E
J11

J11

J11

TON
1'-0"
8

@S
B58 B59 B66
6 2
S507
MATCHLINE:1/S107.2
6 KEY PLAN
B67 B68 B197

Y1.7 CITY OF AUSTIN

B196
J23

J23

30" PAN

B196

B344
19 OWNER

S702
NEW CENTRAL LIBRARY
CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
PROJECT
AUSTIN, TX

A A.3 B C D E Y1.6 F F.1 G J


ENLARGED LEVEL 5 - NORTH
LEVEL 5 FRAMING - NORTH
1 DRAWING TITLE
CIP ID#7235.001

SCALE 1/8" = 1'-0"

N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

SCALE
1/8" = 1'-0" DATE
08/16/2013

JOB NUMBER
3860

DRAWN
TP CHECKED
LN
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S107.1
1/20/2014 11:03:24 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

A B C D E F G
Y1.7 PROJECT CONSULTANT

B255 Y0 SLIDE BEARING SUPPORT


B69 B70 TYP. AT BRIDGES

43" PAN

30" PAN
5 6 5
S801
1
B116

30" PAN

43" PAN
13'-0"

13'-0"
B257

B21
J11

J42

J11

J11
9
B4
J6

J6

J6

J6

J6

J6

B256

30" PAN
S513

E
J11

J11

J11

TON
1'-0"
8
MATCHLINE:1/S107.1

@S
B58 B59 B66
6 2
S507
6 Luke David Nelson No. 98643
B67 B68 B197
10 Datum Reg No. F-2819
Y1.7 S801

B196
T.O.S.C. EL. = 516'-0"
J23

J23

30" PAN B196

B344
19
B3

1 1
S702
@ SCRIM
30" PAN

B252
B104
30'-0"

30'-0"
B32

B32

B32
J13

J13

J13

J13

J13

J13

J13

J13
B276

B20
J5

J5

J5

J5

J5
J5

J5

J5

J5

J5

J5

B2
51
PG

30" PAN
30" PAN

30" PAN

30" PAN
1
30" PAN

30" PAN
12
6 B196

J13

J13
S513 1
S512 SIM. 2#6 X 40'-0" MID-
DEPTH OF SLAB

B239
J13

J13
B71 MC4x13.8
B72 B73 B74 B74 B75
7 7
3 SP. @ 2'-8" REFER TO LEVEL 4
1
PLAN FOR PORCH

10'-0"
2
T.O.S.C. EL. = 516'-0" ROOF FRAMING
B296 SEE ARCH'L
FOR CURB 2 11/15/2013 ADDENDUM #5
1 09/26/2013 ADDENDUM #2

@ STONE
P1 NO. DATE DESCRIPTION
10 20 REVISIONS
S507 S701
30'-0"

30'-0"
10'-0"
B296

B237
19

B31

B31

B31

HSS8X6X1/4
J4

J4

J4

J4

J4

J4

J4

J4

J4

J4

J4

J4

J4

J4

J4

J4
SIM 2 S507
12A
B19
J4
J3
J3
J3

S512 @ WINDOWS
B2
J2

J2

J2

J2

J2

J2

30" PAN
30" PAN

30" PAN

30" PAN
P2
B115

B188
Z

W12X35 TYP.
30" PAN
30" PAN

10'-0"
1
S11

B80 B81
8 8
B187

B79
B79 SLEEVES CAST INTO
BEAM FOR ROOF

10'-0"
MC4x13.8

MC4x13.8

MC4x13.8

MC4x13.8

MC4x13.8
DRAINS, SEE ARCH'L IPE WOOD

HSS8X6X1/4
B30
B78 DECKING
14'-0"

14'-0"
30" PAN

B236
B30

J1

J1

30" PAN J1

J1

J1

J1

J1

J1
B77
P3
B30

J1

J1

30" PAN J1

J1
B76
Z 13
W12X35 TYP. KEY PLAN

TYP. HSS8X4X5/8 CONT.


J1

J1

30" PAN J1

J1

9
S513
BETWEEN LEVEL 3-5 9 CITY OF AUSTIN

10'-0"
J1

B18

HSS8X6X1/4 TYP.
J1
J1
J1

HSS8X6X1/4 HSS8X6X1/4 11
B114

B1
J1

J1

J1

30" PAN J1

J1

J1

30" PAN

S701 1
19 1
S507 S11 MC4x13.8 P4 OWNER
16'-0"

16'-0"
19
B186

MC4x13.8

@ WINDOWS
NEW CENTRAL LIBRARY

W12SP
5 SP. @ 2'-9"
MC4x13.8 S507

8'-3"
W12X35 TYP.
9'-5"

10'-0"
19
S507 13/S701
/ , TYP. MC4x13.8 @ WINDOWS 12 CIP ID#7235.001
S701 W. CESAR CHAVEZ BLVD.
@ WINDOWS 20 MC4x13.8 AUSTIN, TX

7/S701
1'-5"

10 S702 MC4x13.8 16 10 PROJECT

W12SP
K 1 HSS8X4X5/8 W12X35 TYP
S702 MC4x13.8
@ SCRIM .
MC4x13.8
Y0 2
S104.2 MC4X13.8, TYP. ENLARGED LEVEL 5 - SOUTH
PROVIDE W4X13 20 P5
LOCATION OF TEMPORARY SPACER ON TOP OF S701 DRAWING TITLE
CONSTRUCTION CRANE. IPE WOOD
CIP ID#7235.001

W12 @ SKYLIGHTS
DECKING

N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 12'-3"

PA PB PC PD PG

SCALE
1/8" = 1'-0" DATE
08/16/2013
42'-2" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0"
JOB NUMBER
3860
A B 20 C D E F G DRAWN
TP CHECKED
LN
S704
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

1
LEVEL 5 FRAMING - SOUTH
S107.2
1/20/2014 11:03:27 AM

SCALE 1/8" = 1'-0"

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
PLAN NOTES:
1. REFER TO THE SLAB EDGE PLANS IN THE A120 SERIES ARCHITECTURAL
DRAWINGS FOR SLAB EDGE DIMENSIONS.
2. SHADED AND HATCHED REGIONS INDICATE AREAS TO RECEIVE A CONCRETE
TOPPING. REFER TO S506 FOR CONCRETE TOPPING DETAILS. REFER TO SLAB
EDGE PLANS FOR CONCRETE TOPPING EXTENTS AND ELEVATIONS.
3. REFER TO THE S300 SERIES SHEETS FOR CONCRETE COLUMN & SHEAR WALL
SCHEDULES AND TYPICAL DETAILS.
4. REFER TO THE S500 SERIES SHEETS FOR CONCRETE BEAM, JOIST, & SLAB
SCHEDULES AND TYPICAL DETAILS.
5. REFER TO THE SLAB EDGE PLANS FOR EXTENTS OF ARCHITECTURALLY
EXPOSED CONCRETE. REFER TO THE SPECIFICATIONS FOR REQUIREMENTS.
6. REFER TO THE ARCHITECTURAL DRAWINGS FOR RAISED CONCRETE CURB
EXTENTS AND ELEVATION.

Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

PROJECT CONSULTANT

A A.3 B C D D.7 E F F.1 G J


12'-5" 29'-9" 29'-6" 30'-0" 30'-0" Y1
30'-0" 30'-0"

Y1.6
Y1.7
Y1.8
X1 Y2
1'-8" Y3
84'-3
1 " 1
Luke David Nelson No. 98643

14'-6"

14'-6"
Datum Reg No. F-2819

2 2
X2
X1

30'-0"
A.3

30'-0"
1/4"
32'-2
3 3
X3.1

8/S6 8
WB-1

WB-
04
26'-0"

26'-0"
1/S604
X2

"
27'-6
4 4
X2.6

05
05

3/S8
X3

8/S8
30'-0"

30'-0"
NO. DATE DESCRIPTION
REVISIONS
X3.1
Y0 Y1.8
5 F.1 Y2 5
Y3
13'-0"

13'-0"
6 6
Y1.7 J
6.3 6.3

WB
30'-0"

30'-0"
Y1.6
7 7 KEY PLAN

CITY OF AUSTIN
30'-0"

30'-0"
OWNER
Z
WB
NEW CENTRAL LIBRARY
WB-7

WB-6
8 8 CIP ID#7235.001

6/S604
7/S604
W. CESAR CHAVEZ BLVD.
14'-0"

14'-0"
K PROJECT
AUSTIN, TX

9 Z 9
16'-0"

16'-0"
LEVEL 6 - COMPOSITE PLAN

10 K 10 DRAWING TITLE
CIP ID#7235.001

Y0
N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

42'-2" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0"

A B C D D.7 E F G SCALE
As indicated DATE
08/16/2013

JOB NUMBER
3860

TP LN
LEVEL 6 COMPOSITE FRAMING PLAN DRAWN CHECKED
NEW CENTRAL LIBRARY

1 SCALE 1/16" = 1'-0"


PACKAGE 2 CONSTRUCTION DOCUMENTS

S108
1/20/2014 11:03:29 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
A A.3 B C D E F F.1 G J
1'-8" 12'-5" 29'-9" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"

Y1

Y1.6
Lake|Flato
Y1.7 311 Third Street, San Antonio , Texas 78205
X1 55'-5
13'-7
3/8"
Y1.8 T:210.227.3335
www.LakeFlato.com
5/8"
5'-4" Y2 Shepley Bulfinch Richardson & Abbott
@ WINDOW NOTCH IN BEAM 2 Seaport Lane, Boston, Massachusetts 02210
16 9'-10 T:617.423.1700
SOFFIT AT WINDOW "
S512 www.ShepleyBulfinch.com
HEAD, TYP.
17A Y3
1'-8"

S512
1 B133 B134 B134 B135 B136 B83
1
B137
B128
14'-6"

14'-6"
PROJECT CONSULTANT

B138

53" PAN
2 2

S9

B162
1 PROJECT CONSULTANT

16
S512

B189
B23

J14

J14

J14

J30

J30

J30

J30

J14

J14

J14
B7
J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9

J9
@ WINDOW B161

B176

B170
1
X1

J14
J9

J9

J9

J9
2#6 X 60'-0" MID-DEPTH OF SLAB

B190
S9
30" PAN

30" PAN

30" PAN

30" PAN
30'-0"

30'-0"
B127

B152
B7
2
S108.1
1 1

1/4"
C10, BP-5
1 C8 , BP-1
C1, BP-1 C10, BP-5 C6, BP-3

32'-2
TYP 1

B44 B45 B46 B49 B50 C10, BP-5 B51 C6, BP-1 B52 B287
3 3 Luke David Nelson No. 98643
Datum Reg No. F-2819
1

B296
30" PAN

J16

J16

53" PAN
J15
B263
X3.1

B264
8" CURB
1
W8X B156
18/S504 10
TYP.

8
B157
X2

B175

B169
WB-1

WB-
J15

J15

J15
J15/S604
26'-0"

26'-0"
B126

B22
1/S604
J15

J15

J15

J15

J15
B6
J8

J8

J8

J8

J8

J8

S513

8
B296 W8X

B151
10 B144
B158

3/8"
8 C6, BP-3

17'-7
17 LOCATION OF TEMPORARY S513 SIM.
S512 CONSTRUCTION CRANE
B159
B180 B183 B182
4 1 4
B160
X2.6
B338

5/8"
20 20
C6, BP-1 C2, BP-2
30" PAN

S805

9'-10
S703

1
X3 1
NO.
09/26/2013
DATE
ADDENDUM #2
DESCRIPTION

1'-3"
30'-0"

30'-0"
B125

B338 REVISIONS
J7

J7

J7

J7

J7

J7

Y1 X3.1
B295

T.O.S.C. EL. = 533'-0"

B174
4
S513
1

B168
17A
S512 4 B338
C2, BP-1 S513 Y2
B220
5 Y3 5
SLIDE BEARING SUPPORT. S8
1
TYPICAL AT BRIDGES.
J6

J6

J6

30" PAN J6

J6

J6
13'-0"

13'-0"
B124

B21
J16

J16

J42

J16

J34

T.O.S.C. EL. = 535'-0"


B4

B338
43" PAN

1
(T.O. COLUMN PEDESTAL) C6, BP-1
J34

E
J34

J34

TON
1 1 1 1
C10, BP-5 C10, BP-5 C10, BP-5 C10, BP-9 CLASS A FORMWORK B265 8

@S
B58 B230 B231 (ALL SIDES & SOFFIT) S507
6 POUR BEAM &
B266 C4, BP4 MATCHLINE:1/S108.2
6 KEY PLAN
COLUMN PEDESTAL

16
MONOLITHICALLY C4, BP4
1
21'-1 1
CITY OF AUSTIN
5/8"

9'-6"
9'-6"

B167
S512 5 1 T.O.S.C. EL. = 533'-0"
C5, BP-1
J23

J23

S513 (T.O. BEAM)


@ WINDOW
30" PAN

6.3 6.3
B123

B20
J20

J20

J20

J20

J20
J5

J5

J5

J5

J5

J5

19 OWNER
B1 1 S702
63 @ SCRIM 1 NEW CENTRAL LIBRARY
BOT. OF BEAM CIP ID#7235.001
ELEV. = 531'-4" W. CESAR CHAVEZ BLVD.
AUSTIN, TX

J1
PROJECT

A A.3 B C D E F F.1 G J
ENLARGED LEVEL 6 - NORTH
LEVEL 6 FRAMING - NORTH
1 DRAWING TITLE
CIP ID#7235.001

SCALE 1/8" = 1'-0"

N
2 1/4"
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

SCALE
As indicated DATE
08/16/2013

17.50°
JOB NUMBER
3860

TP LN
D DRAWN CHECKED
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

STEEL COLUMN
2 SCALE 1/4" = 1'-0"
S108.1
1/20/2014 11:03:32 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
B

5/S604
WB-5
1

C7 , BP-12 C7 , BP-10
1

T.O.S.C. EL. = 545'-0"

WB-4
4/S604
1 Lake|Flato
311 Third Street, San Antonio , Texas 78205
C1 , BP-11 T:210.227.3335
www.LakeFlato.com
7
Shepley Bulfinch Richardson & Abbott
2
2 Seaport Lane, Boston, Massachusetts 02210
S513 T:617.423.1700
www.ShepleyBulfinch.com
1

C7 , BP-10

PLATFORM AT STAIR
2 SCALE 1/8" = 1'-0"
PROJECT CONSULTANT

A B C D D.7 E F Y1.6 Y1.7 G PROJECT CONSULTANT

C2, BP-1
Y0
B220
5 5
SLIDE BEARING SUPPORT. S8
1
TYPICAL AT BRIDGES.
J6

J6

J6

30" PAN J6

J6

J6
13'-0"

13'-0"
B124

B21
J16

J16

J42

J16

J34
T.O.S.C. EL. = 535'-0"
B4
B338
43" PAN

1
(T.O. COLUMN PEDESTAL) C6, BP-1

J34

E
J34

J34
1

TON
1 1 1 1
C10, BP-5 C10, BP-5 C10, BP-5 C10, BP-9 CLASS A FORMWORK B265 8

@S
B58 B230 B231 (ALL SIDES & SOFFIT) S507 MATCHLINE:1/S108.1
6 POUR BEAM &
B266 C4, BP4
6 Luke David Nelson No. 98643
COLUMN PEDESTAL
MONOLITHICALLY 1 Datum Reg No. F-2819
6.1 16 1
C4, BP4 Y1.7 21'-1 1 6.1
5/8"

9'-6"
9'-6"

B167
S512 S506 5 1 T.O.S.C. EL. = 533'-0"
C5, BP-1
J23

J23

(T.O. BEAM)
B3

S513
@ WINDOW 30" PAN
6.3 6.3
B123

B20
J20

J20

J20

J20

J20
J5

J5

J5

J5

J5

J5

19
1 B252
B1
63 1 S702
@ SCRIM 1
B277
BOT. OF BEAM
SHORE UNDER BEAM
30" PAN

ELEV. = 531'-4"
FOR WALL POUR 15
20'-6"

20'-6"
S801

B232

J1
30" PAN

30" PAN

30" PAN

B232

J1

J1

J1

J1

J1

J1

J1

J1

J1
1

B173

B166
TYP.
6 Y1.6 B196
S513 1
17
SIM. 2#6 X 40'-0" MID-
S512 2 DEPTH OF SLAB
S108.2

J1

J1
C4, BP4

B238
B71 B79 B79 B80 B228
7 B229
7
C1, BP1, TYP 2
S513 2
C4, BP4
B296

43" PAN
30" PAN

30" PAN
43" PAN

53" PAN
53" PAN

53" PAN
53" PAN

53" PAN
53" PAN
53" PAN

53" PAN
1 2 11/15/2013 ADDENDUM #5
1 09/26/2013 ADDENDUM #2
T.O.S.C. EL. = 533'-0"
NO. DATE DESCRIPTION
C4, BP4
B122

19 REVISIONS

ROOF S507
30'-0"

30'-0"
B296

B172

B172

B165
J33

J33

J33

J33

J33

J33
J33

J33

J33

J33

J33

J33
BELOW
17A 2 C4, BP4 @ WINDOWS

B237
J2

J2

J2

J2

J2

J2

S512
30" PAN J3
J3
J3
B2

T.O. CURB EL. = 534'-6"

B172
B188

6" CURB C4, BP4 Z


B19

C4, BP4
J4

J4

J4

J4

1 C3, BP2
30" PAN

C4, BP4
S11
C3, BP2
J4

3'-4"
B80 B228
8 8
B187

B79

WB-6
C3, BP2 WB-7

6/S604
5'-6"
7/S604 B79 T.O. CURB EL. = 535'-0"

B78

B164

14'-0"
C3, BP2

J1
C4, BP4

B171
8" CURB

B171

B236
B77

J1

J1
J1

J1

J1

J1
C4, BP4 C4, BP4
J1

J1

J1
B171

J1

J1

B76 KEY PLAN


B18

J1

13
J1

J1

J1

TYP.
9 Z S513
9 CITY OF AUSTIN
30'-0"

2'-9"
J1

J1

J1

J1

6" 1'-2"
B186

30" PAN
J1

J1

J1

J1

J1

J1

19 1

8" CURB
S11
B1

S507 OWNER

16'-0"
19
30" PAN
B121

@ WINDOWS
19
S507 NEW CENTRAL LIBRARY
S507 @ WINDOWS 16 2'-2" CIP ID#7235.001
WIDEN BEAM TO 30"
@ WINDOWS UNDER COLUMN
S702 W. CESAR CHAVEZ BLVD.
20
K AUSTIN, TX
10 S702 @ SCRIM 10 PROJECT

@ SCRIM 1

Y0 ENLARGED LEVEL 6 - SOUTH


NOTE: MAXIMUM SOIL DEPTH AT
LOCATION OF TEMPORARY
CONSTRUCTION CRANE. ROOF TOP GARDEN SHALL BE 12" DRAWING TITLE
CIP ID#7235.001

OVER RIGID FOAM BOARD, EXPECT


FOR 8'-0" DIA. TREE ROOT BALLS
PERMISSIBLE WHERE SHOWN ON
LANDSCAPING DRAWINGS.
N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

SCALE
1/8" = 1'-0" DATE
08/16/2013
42'-2" 29'-6" 30'-0" 15'-6" 14'-6" 30'-0" 30'-0"
JOB NUMBER
3860
A B 20 C D D.7 E F G TP LN
S704 DRAWN CHECKED
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

1
LEVEL 6 FRAMING - SOUTH
S108.2
1/20/2014 11:03:34 AM

SCALE 1/8" = 1'-0"

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

PROJECT CONSULTANT

A A.3 B C D D.7 E F F.1 G J


42'-2" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"
5
S612
Y1.6
Y1.7
Y1.8
X1 Y2
Y3
1 1
Luke David Nelson No. 98643

14'-6"

14'-6"
Datum Reg No. F-2819

2 2
X2
X1

30'-0"

30'-0"
5/S614

2.9
2.9 WB-3
3 WB-2 3/S604
3
2/S604 X3
X3.1

8/S6 8
15

WB-1

WB-
04
26'-0"

26'-0"
1/S604
S612 X2

4 4

1/S614

4/S614
2/S614

30'-0" X3
X3.1

30'-0"
NO. DATE DESCRIPTION
REVISIONS
3/S614

Y0 Y1.8
5 F.1 Y2 5
Y3
13'-0"

13'-0"
6 6
6.1 6.1
9'-6"

Y1.7 J
6.3 5/S604
8 6/S614 7 6.3

30'-0"
S615 S614
WB-5
20'-6"

WB-4
Y1.6
4/S604
7 7 KEY PLAN

CITY OF AUSTIN
30'-0"

30'-0"
OWNER

NEW CENTRAL LIBRARY


WB-7

WB-6
8 8 CIP ID#7235.001

6/S604
7/S604
W. CESAR CHAVEZ BLVD.
14'-0"

14'-0"
K PROJECT
AUSTIN, TX

9 9
16'-0"

16'-0"
ROOF - COMPOSITE PLAN

10 K 10 DRAWING TITLE
CIP ID#7235.001

Y0
N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

42'-2" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0"

A A.3 B C D D.7 E F G SCALE


1/16" = 1'-0" DATE
08/16/2013

JOB NUMBER
3860

DRAWN
TP CHECKED
LN
NEW CENTRAL LIBRARY

ROOF COMPOSITE FRAMING PLAN PACKAGE 2 CONSTRUCTION DOCUMENTS


1 SCALE 1/16" = 1'-0"

S109
1/20/2014 11:03:36 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
A A.3 B C D E F G J
12'-5" 29'-9" 29'-6" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"

1
13 TYP. @ 3" STEEL DECK, SEE
S613 CORNERS 5 NOTES ON S002 18
S612
X1 S613 Y1.6
1
HSS12X12X1/2 HSS12X8X5/16 HSS12X8X5/16 HSS12X8X5/16 HSS12X8X5/16
Lake|Flato
311 Third Street, San Antonio , Texas 78205
HSS14X4X3/16 HSS14X10X3/8 HSS14X6X1/4 HSS14X6X1/4 HSS14X6X1/4 HSS14X6X1/4 18'-1
1 3/8
Y1.8 T:210.227.3335
www.LakeFlato.com
HSS "
12X8
X1/2
Shepley Bulfinch Richardson & Abbott
HSS 1 2 Seaport Lane, Boston, Massachusetts 02210
1 14X6 T:617.423.1700
X1/4
www.ShepleyBulfinch.com
HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 10
HSS
12X8 S612
X5/1
HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 6
1 HSS
18X6 1
HSS18X6X1/4 HSS18X6X1/4

X1/4 HSS
14X6
W18X76
HSS12X6X1/4

1 X1/4
1 HSS 1
18X6
X1/4
1 HSS
HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 14X4
14'-6"

14'-6"
X3/1
HSS 6 PROJECT CONSULTANT

W18X86

W18X86

W18X86
18X6

W18X106
X1/4
1 HSS
11 18X6 HSS
X1/4 18X6
S612 X1/4 HSS
HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 18X6
2 X1/4 2
HSS

DRAG STRUT
HSS18X6X1/4

3" Metal Roof


18X6 PROJECT CONSULTANT

WT4X15.5
2'-6" TYP.

W18X106
1 HSS X1/4
18X6

(TYP.)

Deck

X86
1 T.O.S. EL. = 554'-9 5/8" X1/4 HSS
6 18X6

6
X1/4

W18

X5/1
S612
HSS

12X8
HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 18X6
1 X1/4

X76
HSS12X6X1/4

X1

HSS
HSS
18X6

W18
HSS18X6X1/4

HSS X1/4
1 18X6
W18X76

1 X1/4
30'-0"

30'-0"
1 19 1
HSS

3'-3" TO SLAB EDGE


S613 18X6

3'-3" TO SLAB EDGE


X1/4
5/S614
HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 1 HSS18X6X1/4 HSS18X6X1/4 1 HSS18X6X1/4 HSS HSS
18X6 18X6 HSS18X6X1/4, TYP.
8 SIM. 3 1 X1/4 X1/4
SIM. 1
HSS18X6X1/4

3 9 6

4" TYP.
10 1 S613 S613

1/4"
S613 S613 S613 S613 1 1 HSS
1 18X6
2.9 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 X1/4 2.9

32'-2
HSS
18X6
X1/4

3'-7"
W8X28 W16X31 W16X31

2'-4"
W12X19 W12X19 W16X31 W16X31 2 5

W8X28

W8X28
HSS18X6X5/8 HSS18X6X5/8 W16X26 (12) W16X26 (10) W18X35 (25) 2
3 S613 3 Luke David Nelson No. 98643

28
(8)
W18X35 (17) HSS Datum Reg No. F-2819
DRAG STRUT
HSS18X6X1/4
HSS18X6X1/4

19

W8X
W16X26 (15) DRAG STRUT G HSS 18X6
WB-3 1

X19

W18X106
G S602 18X6 S603 X1/4
(TYP.)

TYP. 3/S604 X1/4


1
WB-2

W12
S602

X19
31 TYP.
2 ON 3 /2" LW. C T.O.S.C. EL. = 553'-10 1/8" TYP.
2/S604 T.O.S.C. EL. = 553'-10 1/8" 2 X3.1

W12
S611 DEC " COMP ONC.

(13)
.

W12X19 (15)
K (6
HSS18X6X5/8 HSS18X6X5/8 1 1/2" STEEL

(15)
W8X HSS

(23)
TOT HSS 1 18X6
10 X1/4

X19
AL) 18X6

(30)
X19
HSS18X6X1/4

J X1/4

W16X26 (16)

W16X26 (16)
W16X26 (16)

W16X26 (32)

X19
15

8/S6 8
W18X106

W12
W16X26
X2

X68
J

W12
WB-1 S601

WB-
04
26'-0"

26'-0"
S612

W12
1 W12
1/S604
HSS12X6X1/4

W18X76

S601

6
X19

W14
1

X5/1
(9) 1 W8X HSS
28 18X6

12X8
1 HSS18X6X5/8 HSS18X6X5/8 W8X B355 X1/4

X76
10 HSS 1
3 1/2" LW CONC. 2 18X6

W18

HSS
X1/4
HSS18X6X1/4

ON 3" COMP.
7 T.O.S. EL. = 554'-9 5/8" 1 STEEL DECK (6
1 1/2" TOTAL) HSS
S613
W16 18X6
X1/4

"
X26

27'-6
(6) HSS
3"

HSS18X6X5/8 HSS18X6X5/8 W16X26 (12) W16X31 (28) H=15 18X6


k X1/4
4 4
W8X28

W8X28

W8X28

W8X28
11/S616. H=15
PROVIDE L3X3X1/4 k
HSS18X6X1/4

SIM. KICKER FROM W33 BOT. HSS


W12X19 W12X19 W12X19 HSS 18X6
SHADED AREA INDICATES FLANGE TO W16 BOT. 18X6 X1/4
1 X1/4
PL.1/4"X AS SHOWN W16X26 FLANGE HSS HSS
UNDER ROOF DECK M 14X6 18X6
X1/4 X1/4
.
11/S616 TRUSS END
1/S614

4/S614
HSS18X6X5/8 HSS18X6X5/8 TRUSS END S601
VERT.
VERT. 2 11/15/2013 ADDENDUM #5
(STACKED)

1
WT18X90
W18X106

HSS
14X4 1 X3 1 09/26/2013 ADDENDUM #2
HSS18X6X1/4

PROVIDE 5/8" DIA. 5 HSS X3/1


6 NO. DATE DESCRIPTION

1'-3"
15 PUDDLE WELDS THRU SIM. 12X8
30'-0"

30'-0"
S612 X5/1 REVISIONS
S612
1 PLATE @ 6" 6 X3.1
10
HSS12X6X1/4

1
S616
W18X76

HSS18X6X5/8 1 HSS18X6X5/8 ALIGN TOP OF W33


1

OP
WITH B.O. COMPOSITE
HSS18X6X1/4

METAL DECK

& BO 21X44 T
11/S616.
1 SIM. Y1.8

T.
W/ W
6
S616

X201
HSS18X6X5/8 HSS18X6X5/8
5 5
HSS18X6X1/4 HSS18X6X1/4HSS18X6X1/4

W33
5
W18X76

1 1
S616
1
HSS18X6X5/8 HSS18X6X5/8 T.O.S. EL. = 552'-6 7/8" (W.P.)
13'-0"

13'-0"
7
W18X76

T.O.S. EL. = 552'-6 7/8" 1


1 S616
8
S613
HSS18X6X5/8 HSS18X6X5/8
6 6

2'-4"
KEY PLAN
3'-7"

W18X60 MATCHLINE:1/S109.2
6.1 1 WARPED DECK 6.1 CITY OF AUSTIN
HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4

W18X76
9'-6"

1 TYP. HSS18X6X1/4 W14X61

9'-6"
X76
15 SOUTH OF GRID 6
W18X76

W18
S612
HSS12X6X1/4

HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4


6.3 7
6.3
W18X76

1 5/S604
6/S614 S614 HSS18X6X1/4 HSS18X6X1/4 OWNER

WB-5 NEW CENTRAL LIBRARY


HSS18X6X1/4 HSS18X6X1/4
CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
PROJECT
AUSTIN, TX
Y1.6
A A.3 B C D E F G J
ENLARGED ROOF PLAN -
NORTH
ROOF LEVEL - NORTH DRAWING TITLE

1
CIP ID#7235.001

SCALE 1/8" = 1'-0"

N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

SCALE
1/8" = 1'-0" DATE
08/16/2013

JOB NUMBER
3860

DRAWN
TP CHECKED
LN
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

S109.1
1/20/2014 11:03:38 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

PROJECT CONSULTANT

A B C D D.7 E F Y1.6 G

Y0 S616

HSS18X6X5/8 HSS18X6X5/8
5 5
HSS18X6X1/4 HSS18X6X1/4HSS18X6X1/4

7
W18X76

1 1 5
1 S616 S616
HSS18X6X5/8 HSS18X6X5/8 T.O.S. EL. = 552'-6 7/8" (W.P.)
13'-0"

13'-0"
W18X76
T.O.S. EL. = 552'-6 7/8" 1
1 8
S613
HSS18X6X5/8 HSS18X6X5/8 MATCHLINE:1/S109.1
6 6

2'-4"
Luke David Nelson No. 98643

3'-7"
W18X60
Datum Reg No. F-2819
6.1 1 WARPED DECK HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 6.1

W18X76
9'-6"

1 TYP. 19 HSS18X6X1/4 W14X61

9'-6"
X76
15 SOUTH OF GRID 6
W18X76

W18
S612 S603
HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4
6.3 6.3

W18X76
1 5/S604
6/S614
HSS18X6X1/4 HSS18X6X1/4
1 PV ARRAY
HSS18X6X1/4

WB-5
HSS12X6X1/4

S109.3 FRAMING

W18X76
1 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4

W18X76
1
W18X76

HSS12X8X5/16 HSS12X8X5/16
W14X61
HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4
20'-6"

20'-6"
W18X76

HSS18X6X5/8 20

W14X61 (LOW)

W14X61 (LOW)
SIM.
Y1.6

HSS8X4X3/8

HSS8X4X3/8

HSS8X4X3/8
HSS18X6X1/4

10 S612
HSS18X6X1/4
DRAG STRUT, TYP. S613 TYP.

HSS12X8X5/16
WB-4

1
4/S604

2
HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 W14X61
7 7
HSS18X6X1/4

2 PV ARBOR SUPPORT
S513 SIM. O.H. TYP. NO STEEL ROOF DECK
1 12 THIS AREA
S613
2 11/15/2013 ADDENDUM #5
W18X86

HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 1 09/26/2013 ADDENDUM #2


NO. DATE DESCRIPTION
W18X76

HSS18X6X1/4 DRAG STRUT, TYP.

W18X76
REVISIONS
HSS12X6X1/4

HSS18X6X1/4

1'-0
7/8" W14X61
30'-0"

30'-0"
1 3" Metal Roof 15
W18X76

1 TYP. Deck
12 S613
S613

W18X76
HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4

2 HSS18X6X1/4, TYP.
HSS18X6X1/4

HSS12X8X5/16
1

HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 HSS18X6X1/4 W14X61


8 8

WB-6
WB-7

6/S604
HSS18X6X1/4

7/S604

HSS8X4X3/8

HSS8X4X3/8

HSS8X4X3/8

HSS8X4X3/8

HSS8X4X3/8
1 3" DECK SPAN
14'-0"

14'-0"
HSS12X6X1/4

W18X106

HSS18X6X5/8 HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4 K


W18X106

HSS18X6X1/4 HSS18X6X1/4
KEY PLAN
1
HSS18X6X1/4

9 Z T.O.S. EL. = 547'-11 3/4"


W14X61
9 CITY OF AUSTIN
1
W18X106
W18X106

Pipe3XS HSS12X8X5/16
HSS18X6X1/4
W18X106

HSS18X6X5/8 HSS18X6X1/4 HSS18X6X1/4


HSS18X6X1/4 OWNER
HSS18X6X1/4
16'-0"

16'-0"
HSS18X6X5/8 HSS18X6X1/4
16'-8 1/8"

HSS18X6X1/4

HSS18X6X1/4 1
1 HSS18X6X1/4 1 NEW CENTRAL LIBRARY
HSS18X6X5/8 HSS18X6X1/4 1 CIP ID#7235.001
16
HSS18X6X5/8 1 1 TYP. S612 W. CESAR CHAVEZ BLVD.
HSS18X6X5/8 1 AUSTIN, TX
10 K 1 HSS14X6X1/4
10 PROJECT

HSS18X6X5/8
HSS12X6X1/4

HSS14X6X1/4
2
1 HSS14X6X1/4
13 SIM. ENLARGED ROOF PLAN -
HSS14X6X1/4 S613 TYP. @ CORNERS
1
SOUTH
HSS12X8X5/16 HSS12X8X5/16
HSS14X10X3/8 DRAWING TITLE
CIP ID#7235.001

HSS14X6X1/4 1 HSS12X8X5/16 LOCATION OF TEMPORARY


CONSTRUCTION CRANE.
HSS12X12X1/2
1
20
3" STEEL DECK, SEE
N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

S612 NOTES ON S002

Y0
SCALE
1/8" = 1'-0" DATE
08/16/2013
42'-2" 29'-6" 30'-0" 15'-6" 14'-6" 30'-0" 30'-0"
JOB NUMBER
3860
A B 20 C D D.7 E F G TP LN
S704 DRAWN CHECKED
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

ROOF LEVEL - SOUTH


1 S109.2
1/20/2014 11:03:39 AM

SCALE 1/8" = 1'-0"

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com

PROJECT CONSULTANT

PROJECT CONSULTANT

Luke David Nelson No. 98643


Datum Reg No. F-2819

NO. DATE DESCRIPTION


REVISIONS

B C D

HSS6X4X1/4 HSS6X4X1/4 HSS6X4X1/4 HSS6X4X1/4

HSS6X4X1/4
HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4
7 7
KEY PLAN

CITY OF AUSTIN
HSS6X4X1/4 HSS6X4X1/4 HSS6X4X1/4 HSS6X4X1/4

OWNER

NEW CENTRAL LIBRARY


HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4
HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4
CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
PROJECT
AUSTIN, TX

HSS6X4X1/4 HSS6X4X1/4 HSS6X4X1/4 HSS6X4X1/4


PV ARRAY FRAMING
8 8
DRAWING TITLE
CIP ID#7235.001

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4
HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4

HSS6X4X1/4
HSS6X4X1/4

HSS6X4X1/4
HSS6X4X1/4

HSS6X4X1/4
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

HSS6X4X1/4 HSS6X4X1/4

9 9
HSS6X4X1/4 HSS6X4X1/4

SCALE
1/8" = 1'-0" DATE
08/16/2013

JOB NUMBER
3860

DRAWN
TP CHECKED
LN
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

B C D

S109.3
1/20/2014 11:03:41 AM

ROOF LEVEL - PV ARBOR FRAMING


1 SCALE 1/8" = 1'-0"

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
www.LakeFlato.com

Shepley Bulfinch Richardson & Abbott


2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
www.ShepleyBulfinch.com
B C D E F
Y1.6
1 1'-5" 29'-6" 30'-0" 30'-0" 30'-0" 5'-0" 10'-0"

1'-5"
1
HSS3X3X3/8 @ 3'-0"
WITHIN DECK FLUTES
1" DIA. ROD W/ NO. 2 1/2 PROJECT CONSULTANT

CLEVISES & 1 1/4" DIA. PINS


W14X22 X CONT.
BETWEEN GRIDS C & E
HSS6X4X3/16 X CONT. ( LSV )
SEE SECTION
T.O.S. EL. = 569'-5 1/4"
5/S614 HSS6X4X3/16 X CONT. ( LSV )
PROJECT CONSULTANT
LIFTING HOOKS. TROLLEY BEAM. W14X30 BEYOND TUBE, TYP. 1
SEE 2/S613, TYP. SEE 1/S613, TYP.

1 3" Metal Roof 1


Deck
2.9 S613
2.9

7'-6"

2'-4"
HSS14X10X3/8 HSS14X10X3/8 HSS14X10X3/8 HSS14X10X3/8 HSS14X10X3/8
3 3
WB-3
3/S604
WB-2
2/S604

X40
W16X40

W16
LOCATION OF TEMPORARY HSS6X4X1/4 ( LSV ) SKYLIGHT
1 CONSTRUCTION CRANE FRAMING MEMBER

W16X40

W16X40
PLAN NOTE 1

26'-0"
W16X40

W16X40

W16X40

W16X40

W16X40

W16X40

W16X40

W16X40

W16X40
3" Metal Roof

W16X40

W16X40
EL. = 558'-10 1/4" W16X40

Deck
Luke David Nelson No. 98643
1 3/8" DIA. ROD W/ NO. 3 1/2 Datum Reg No. F-2819

EL. = 559'-11 3/4"

EL. = 559'-11 3/4"


EL. = 558'-10 1/4"

EL. = 558'-10 1/4"


CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM
EL. = 560'-4 1/4"

EL. = 560'-8 3/4"

EL. = 561'-1 1/4"

EL. = 560'-8 3/4"

EL. = 560'-4 1/4"


CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM
CLEVISES & 1 3/4" DIA. PINS
CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

EL. = 559'-7 1/4"

EL. = 559'-7 1/4"

CRICKET BEAM

CRICKET BEAM
EL. = 559'-2 3/4"

EL. = 559'-2 3/4"

/4"
558'- AM
BEYOND GRIDS C TO E

10 1
EL. = KET BE
T.O.S. EL. =
556'-7 1/2"

CRIC
4 7/S615,
. SIM.
4
HSS6X4X1/4 (LSV)

SV)
TRUSS T1
HSS6X4X1/4 (LSV)

LSV)
HSS4X4X5/16

1/4 (L
SKYLIGHT FRAMING 1'-0"
Pipe6STD

Pipe6STD

Pipe6STD

Pipe6STD

Pipe6STD

Pipe6STD

Pipe6STD

Pipe6STD

Pipe6STD

Pipe6STD

1/4 (
1/S614

4/S614
1'-0" COLUMN, TYP.

Pipe6STD
2/S614

Pipe6STD

6X4X

6X4X
4

HSS

HSS
S616 .
6/S615,

30'-0"
TRUSS T2 SIM.

EL. = 559'-11 1/4"


CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM

CRICKET BEAM
EL. = 558'-1 1/4"

EL. = 558'-1 1/4"

EL. = 558'-7 1/4"

EL. = 559'-1 1/4"

EL. = 559'-7 1/4"

EL. = 560'-1 1/4"

EL. = 560'-7 1/4"

EL. = 561'-1 1/4"

EL. = 560'-6 1/4"

EL. = 559'-4 1/4"

EL. = 558'-9 1/4"

EL. = 558'-2 1/4"

-2 1/ M
4"
A
6 7

EL. = KET BE
3/S614 S615 S615
8

558'
T.O.S. EL. =
S615 556'-6 1/2"

CRIC
W16X40
3 2 11/15/2013 ADDENDUM #5

W16X40

W16X40
W16X40

1 09/26/2013 ADDENDUM #2
W16X40

W16X40

W16X40

W16X40

W16X40

W16X40

W16X40

W16X40
S615 20
5 5 NO. DATE DESCRIPTION
W16X40

S615 REVISIONS

X40
PLAN NOTE 1

W16
1 3/8" DIA. ROD W/ NO. 3
1/2 CLEVISES & 1 3/4"

13'-0"
3" Metal Roof
Deck DIA. PINS BEYOND GRIDS
3
C TO E
S616

HSS14X10X3/8 HSS14X10X3/8 HSS14X10X3/8 HSS14X10X3/8


6 2 6

2'-4"
S616

7'-6"
1 3" Metal Roof
6.1 S616
Deck 6.1
1

11
17 W14X30 BEYOND TUBE, TYP.
6/S614 7 S615
S615 HSS6X4X3/16 X CONT. ( LSV )
S614
1'-5" T.O.S. EL. = 565'-9 5/8" W14X22 X CONT.
1 @ THE
COLUMN HSS6X4X3/16 X CONT. ( LSV ) 1'-5"
SEE SECTION 1
1" DIA. ROD W/ NO. 2 1/2 KEY PLAN

B C CLEVISES & 1 1/4" DIA. PINS D HSS3X3X3/8 @ 3'-0" E F CITY OF AUSTIN


BETWEEN GRIDS C & E WITHIN DECK FLUTES
Y1.6

OWNER

NEW CENTRAL LIBRARY


CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
AUSTIN, TX
HIGH ROOF FRAMING PLAN PROJECT

1 SCALE 1/8" = 1'-0"

HIGH ROOF FRAMING PLAN


DRAWING TITLE
CIP ID#7235.001

N
C:\Users\Tony.DATUM\Documents\Local Revit Files\Revit 2013 Local\ACL_CENTRAL_STRUCT - 2_Tony.rvt

SCALE
As indicated DATE
08/16/2013

JOB NUMBER
3860
PLAN NOTES TP LN
DRAWN CHECKED
NEW CENTRAL LIBRARY

1. PROVIDE L4X4X1/4 X CONT. BOTTOM FLANGE BRACING. AT


THE CENTER TWO BAYS (20’-0”), PROVIDE AN L4X4X1/4 TOP
PACKAGE 2 CONSTRUCTION DOCUMENTS
MEMBER BETWEEN TOP FLANGES AND L4X4X1/4 DIAGONALS
CONNECTING THE TOP L4X4 MEMBERS TO THE BOTTOM L4X4
BRIDING. PROVIDE 1 1/2" OF 3/16" FILLET WELD, EA. END.

S110
1/20/2014 11:03:43 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
COMPRESSION
TENSION
DEVELOPMENT & SPLICE LENGTH SCHEDULE HOOKED DOWEL SCHEDULE
DEVELOPMENT & SPLICE LENGTH SCHEDULE
MINIMUM MINIMUM
MINIMUM MINIMUM SPLICE
CONCRETE STEEL COMPRESSION COMPRESSION
CONCRETE STEEL TENSION TENSION BAR SIZE CONCRETE STEEL LENGTH MIN LENGTH OF
BAR SIZE STRENGTH STRENGTH DEVELOPMENT LAP SPLICE BAR SIZE HOOK LENGTH
STRENGTH STRENGTH DEVELOPMENT LAP SPLICE LENGTH STRENGTH STRENGTH (CLASS B, EXTENSION
LENGTH LENGTH
LENGTH (CLASS B) TENSION)

#3 8" 1'
#3 1'‐8" 2'‐0" #3 2'‐0" 8" 6"
#4 10" 1'‐3"
#4 2'‐2" 2'‐8" #4 2'‐8" 10" 8"
60 KSI
60 KSI 60 KSI
#5 1' 1'‐7"
#5 2'‐8" 3'‐4" #5 3'‐4" 1'‐0" 10"
#6 1'‐3" 1'‐11"
#6 3'‐2" 4'‐0" #6 4'‐0" 1'‐3" 1'‐0"
#7 1'‐9" 3'‐3"
#7 5'‐8" 7'‐4" #7 7'‐4" 1'‐9" 1'‐2" Lake|Flato
4,000 PSI 311 Third Street, San Antonio , Texas 78205
4,000 PSI 4,000 PSI
#8 2' 3'‐8" T:210.227.3335
#8 6'‐6" 8'‐5" #8 8'‐5" 2'‐0" 1'‐4" www.LakeFlato.com
#9 2'‐3" 4'‐2" Shepley Bulfinch Richardson & Abbott
#9 7'‐3" 9'‐6" #9 9'‐6" 2'‐3" 1'‐6"
75 KSI 2 Seaport Lane, Boston, Massachusetts 02210
75 KSI 75 KSI T:617.423.1700
#10 2'‐7" 4'‐8"
#10 8'‐2" 10'‐8" #10 10'‐8" 2'‐7" 1'‐9" www.ShepleyBulfinch.com

#11 2'‐10" 5'‐2"


#11 9'‐3" 11'‐10" #11 11'‐9" 2'‐10" 2'‐0"
#14 5'‐4" 9'‐10"
#14 14'‐6" MECH'L. SPLICE #14 MECH'L. SPLICE 4'‐6" 3'‐0"
#3 8" 1'
#3 1'‐4" 1'‐8" #3 1'‐8" 6" 6"
#4 9" 1'‐3"
#4 1'‐9" 2'‐3" #4 2'‐3" 8" 8" PROJECT CONSULTANT
60 KSI
60 KSI 60 KSI
#5 1' 1'‐7"
#5 2'‐2" 2'‐9" #5 2'‐9" 10" 10"
#6 1'‐2" 1'‐11"
#6 2'‐7" 3'‐4" #6 3'‐4" 12" 1'‐0"
#7 1'‐8" 3'‐3" PROJECT CONSULTANT
#7 4'‐8" 6'‐0" #7 6'‐0" 1'‐5" 1'‐2"
6,000 PSI
6,000 PSI 6,000 PSI
#8 1'‐11" 3'‐8"
#8 5'‐3" 6'‐10" #8 6'‐10" 1'‐8" 1'‐4"
#9 2'‐2" 4'‐2"
#9 6'‐0" 7'‐9" #9 7'‐9" 1'‐10" 1'‐6"
75 KSI
75 KSI 75 KSI
#10 2'‐5" 4'‐8"
#10 6'‐8" 8'‐8" #10 8'‐8" 2'‐1" 1'‐9"
#11 2'‐8" 5'‐2"
#11 7'‐6" 9'‐8" #11 9'‐8" 2'‐4" 2'‐0"
#14 5'‐1" 9'‐10"
#14 12'‐0" MECH'L. SPLICE #14 MECH'L. SPLICE 3'‐8" 3'‐0"

NOTES:
NOTES:
1. SEE DETAILS FOR LOCATIONS OF DEVELOPED BAR ENDS AND SPLICES.
1. TENSION SPLICES SHALL BE USED UNLESS SPECIFICALLY NOTED OTHERWISE.
2. BAR DEVELOPMENT LENGTHS AND SPLICE LENGTHS SHALL COMPLY WITH THE LENGTHS IN THE TENSION
2. SEE DETAILS FOR LOCATIONS OF DEVELOPED BAR ENDS AND SPLICES.
SCHEDULE UNLESS SPECIFICALLY NOTED OTHERWISE.
3. BAR DEVELOPMENT LENGTHS AND SPLICE LENGTHS SHALL COMPLY WITH THE LENGTHS IN THE TENSION
3. LAP SPLICE LENGTHS ARE TO BE CALCULATED BASED ON THE SMALLER BAR BEING LAPPED.
SCHEDULE UNLESS NOTED OTHERWISE.

4. LAP SPLICE LENGTHS ARE TO BE CALCULATED BASED ON THE SMALLER BAR BEING LAPPED.
TERMINATING
COLUMN, WALL,
OR BEAM BAR

LENGTH
SPLICE
LAP
JOINT OR CRITICAL SECTION

EXTENSION
LENGTH
HOOK
LENTGH

NOTES:

1. DOWEL SPACING AND BAR SIZE TO BE THE SAME AS THE TERMINATING COLUMN, BEAM OR WALL
BAR. DOWELS SHALL BE SPLICED WITH TERMINATING BARS AS INDICATED ON THE DETAILS.

2. WHERE CONCRETE STRENGTHS VARY EACH SIDE OF JOINT, SELECT SPLICE LENGTH BASED ON
CONCRETE STRENGTH OF COLUMN, BEAM OR WALL THAT IS TERMINATING. SELECT EXTENSION NO. DATE DESCRIPTION
AND HOOK LENGTHS BASED ON STRENGTH OF CONCRETE SURROUNDING THE HOOK. REVISIONS

NOTES:
SEE 1. PROVIDE CORNER BARS TO MATCH SIZE, KEY PLAN

ARCH'L SEE SPACING AND LOCATION OF ALL HORIZONTAL


ARCH'L BARS UNLESS OTHERWISE NOTED. CITY OF AUSTIN
2. CORNER BARS ARE NOT REQUIRED AT
HOOKED ENDS. TURN HOOKS SIDEWAYS.
INTERIOR CMU INTERIOR CMU 3. FABRICATOR TO LOCATE THESE BARS ON THE
WALL PER ARCH'L WALL PER ARCH'L SHOP DRAWINGS.
OWNER

REINF'G PER ARCH'L REINF'G PER ARCH'L


NEW CENTRAL LIBRARY
CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
PROJECT
AUSTIN, TX
PROVIDE HORIZ. CORNER BARS EACH FACE TO
LAP SPLICE MATCH SMALLER BAR AT
TRUSS-TYPE REINF.
PROVIDE HORIZ. TRUSS- PER ARCH'L PER SCHEDULE INTERSECTION.
SE GENERAL NOTES

TYPE REINF. PER ARCH'L COMMON SCHEDULES &


SEE GENERAL NOTES

DETAILS

PER SCHEDULE
DRAWING TITLE
CIP ID#7235.001

LAP SPLICE

TYPICAL
CONCRETE TOPPING (IF ANY) CONCRETE TOPPING (IF ANY)

STRUCTURAL SLAB STRUCTURAL SLAB


CORNER BARS
EA. FACE TO CORNER BARS
GENERAL

MATCH BARS IN
NOTES
SEE

DISCONTINUOUS DETAILED REINFORCING


CMU DOWEL SAME SIZE & SHALL STOP 2" SHORT
GENERAL

MEMBER
NOTES

CMU DOWEL SAME SIZE & SPACING AS CMU REINF'G OF FORM,TYPICAL


SEE

SPACING AS CMU REINF'G


IF STRUCTURE IS TOO SHALLOW IF STRUCTURE IS TOO SHALLOW
FOR STRAIGHT BAR, THEN HOOK FOR STRAIGHT BAR, THEN HOOK As indicated 08/16/13
PER DOWEL SCHEDULE PER DOWEL SCHEDULE PLAN VIEW SCALE DATE

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER
THIS DETAIL APPLIES TO WALL-WALL INTERSECTIONS,
CMU ON STRUCTURAL SLAB CMU ON CONCRETE TOPPING BEAM-BEAM INTERSECTIONS, AND WALL-BEAM INTERSECTIONS. Author Checker
DRAWN CHECKED
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

TYPICAL DETAIL TYPICAL DETAIL


1 REINFORCED INTERIOR CMU ON LEVELS P2 & P1 2 CORNER BARS AT WALL & BEAM INTERSECTIONS S200
8/14/2013 11:46:00 PM

3/4" = 1'-0" 3/4" = 1'-0"

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
BASEMENT

Shepley Bulfinch
A Joint Venture
WALL PER PLAN
WALL
A A.3 B C D E F G H J THICKNESS
PILASTER PER PLAN
PER SCHEDULE

1 CONTINUOUS WATERPROOFING PER ARCH'L CONCRETE PILASTER PER


Y3 PLAN & COLUMN SCHEDULE
2
PERIMETER BASEMENT WALL BASEMENT WALL
PER PLAN & SCHEDULE REINFORCING BASEMENT WALL BEYOND
X1

PER SCHEDULE
PER SCHEDULE

LAP SPLICE
CONT. 2x8 SHEAR KEY - TYP. 10 MIL POLYPROP SLIP

LAP SPLICE
BARRIER BETWEEN
3 MAT SLAB & TOPPING PILASTER REINFORCING
SLOPED CONCRETE
CONCRETE - TYPICAL
TOPPING PER PLAN
X2

4 COMPRESSION MAT'L
PER TOPPING COMPRESSION MAT'L PER
GENERAL NOTES TOPPING GENERAL NOTES
X3.1 Lake|Flato
311 Third Street, San Antonio , Texas 78205
T:210.227.3335
5 www.LakeFlato.com
MAT SLAB NOTES: 3' - 3" 3' - 3"
TEMPORARY RETENTION Shepley Bulfinch Richardson & Abbott
6 1. APPLIES TO TOP AND BOTTOM 2 Seaport Lane, Boston, Massachusetts 02210
REINFORCEMENT, EACH WAY. SYSTEM (CONTINUOUS PROVIDE HOOKED
WWM PER T:617.423.1700

MAT SLAB THICKNESS PER PLAN


LAGGING ON SOLDIER PILES) DOWELS @ EACH www.ShepleyBulfinch.com
GENERAL NOTES
2. SEE MAT SLAB TYPICAL DETAILS PILASTER VERTICAL BAR -
SEE 2/S201 FOR MATCH PILASTER BAR
FOR ADDITIONAL REINFORCEMENT TEMP. RETENTION &
AT COLUMN AND SHEAR WALLS. TYPICAL MAT SLAB SIZE - SEE DOWEL

~
7 CONTINUOUS WATERPROOFING INFO) SCHEDULE
WATERPROOFING - REINFORCING PER PLAN
3. ALL MAT SLAB REINFORCEMENT SEE ARCHITECTURAL
TOP & BOTTOM SHALL BE SPLICED #6 C-BAR AT SLAB EDGE -
PROVIDE HOOKED DOWEL @
AT CENTERLINE BETWEEN COLUMNS. SPACE WITH TOP & BOTTOM SLAB BARS
EACH VERTICAL WALL BAR -
MATCH WALL BAR SIZE -
8 SEE DOWEL SCHEDULE HOOK PROJECT CONSULTANT
LEGEND PER SCHED.
9 #6 C-BAR AT SLAB EDGE - TYPICAL
#10's @ 12" O.C. SPACE WITH TOP & BOTTOM SLAB BARS

10
#10's @ 6" O.C.
PROJECT CONSULTANT

11
#11's @ 6" O.C.
~
TYPICAL DETAIL SEE 2/S201 FOR WATERPROOFING
AND MUD SLAB A
TE
OF T
EX
A

T
S

S
1 MAT SLAB REINFORCING PLAN CONTINUOUS 4" THICK 4" THICK FIBER
WATERPROOFING - MUD SLAB REINFORCED
1/32" = 1'-0" SEE ARCH'L WORKSLAB JOELLE S. ROSENTSWIEG

R
PR
TYPICAL DETAIL TYPICAL DETAIL 89451

E
E
L

O
IC D
ENSE

N
F
E
S G

2 MAT SLAB AT BASEMENT WALL 3 MAT SLAB AT PILASTER S N


ONAL E

CONCRETE COLUMN 3/4" = 1'-0" 3/4" = 1'-0"


PER PLAN & SCHEDULE

COLUMN BASE DOWELS


SHALL LAP ON THE INSIDE
PER SCHEDULE

OF COLUMN VERTICAL
LAP SPLICE

BARS - SEE SECTION SLOPED CONCRETE ADDITIONAL NORTH-SOUTH BARS TOP &
TOPPING PER PLAN BOTTOM, EACH WAY PER COLUMN
SCHEDULE (MAT SLAB TYPICAL NOTE: LENGTH OF BARS IN BOTH
REINFORCING NOT SHOWN FOR CLARITY) NO. OF PARALLEL BARS & SPACING DIRECTIONS SHALL BE CENTERED ABOUT
SHEAR WALL CENTERLINE (TYPICAL U.N.O.)
COMPRESSION PER ENLARGED SHEAR WALL PLANS (TYP.)
MAT'L PER TOPPING MAT SLAB PER PLAN ADDITIONAL EAST-WEST BARS TOP &
BOTTOM, EACH WAY PER COLUMN EQUAL EQUAL
GENERAL NOTES
SCHEDULE (MAT SLAB TYPICAL
CONCRETE COLUMN ABOVE
REINFORCING NOT SHOWN FOR CLARITY)
MAT SLAB THICKSNESS PER PLAN

MAY ADJUST AS NECESSARY TO CLEAR COLUMN REINFORCING


TYPICAL MAT SLAB

MAY ADJUST AS NECESSARY TO CLEAR WALL REINFORCING


REINFORCING PER PLAN
1'-0" LONG 2x8 SHEAR KEY @ COLUMN
CENTERLINE - KEY SHALL RUN IN CONCRETE SHEAR
NORTH-SOUTH DIRECTION - TYP.

PER ENLARGED SHEAR WALL PLANS (TYP.)


EQUAL

NO. OF PERPENDICULAR BARS & SPACING


COLUMN BASE DOWELS PER COLUMN SCHEDULE WALL ABOVE
- LAP DOWEL WITH EACH COLUMN VERTICAL BAR
PER COLUMN SCHEDULE (TYP.)

EQUAL SPACES (TYPICAL)


NO. OF BARS & SPACING

EQUAL SPACES
TYPICAL
HOOK PER
SCHED. TYP
~ 1
NO.
09/26/2013
DATE
ADDENDUM #2
DESCRIPTION
SEE 2/S201 FOR WATERPROOFING AND MUD SLAB REVISIONS

TYPICAL DETAIL
EQUAL

4 MAT SLAB AT INTERIOR COLUMN


3/4" = 1'-0"

COLUMN DOWELS
PER SCHEDULE
1

PLAN VIEW
NOTE: LENGTH OF BARS IN BOTH
DIRECTIONS SHALL BE CENTERED ADDITIONAL PARALLEL &
ABOUT COLUMN GRID INTERSECTION. PERPENDICULAR BARS TOP &
DELETED BOTTOM, EACH WAY PER ENLARGED
SHEAR WALL PLANS (MAT SLAB
TYPICAL REINFORCING NOT SHOWN
FOR CLARITY)
SHEAR WALL PER PLAN KEY PLAN

PER SCHEDULE
DELETED
1
CITY OF AUSTIN

LAP SPLICE
PLAN VIEW COLUMN PER PLAN & DELETED
SLOPED CONCRETE SCHEDULE (REINFORCING &
TOPPING PER PLAN SPLICE DOWEL NOT SHOWN
FOR CLARITY) COMPRESSION SLOPED CONCRETE OWNER
MAT'L PER TOPPING TOPPING PER PLAN
GENERAL NOTES
COMPRESSION MAT'L DELETED NEW CENTRAL LIBRARY
PER TOPPING TYPICAL MAT REINFORCING PER PLAN
GENERAN NOTES CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
PROJECT
AUSTIN, TX

MAT SLAB FOUNDATION

MAT SLAB THICKNESS PER PLAN


INTERMITTENT 1'-0" LONG 2x4 TYPICAL MAT SLAB
DETAILS

MAT SLAB THICKNESS PER PLAN


ARRANGE TOP BARS AS REQUIRED SHEAR KEY @ 2'-0" O.C. - REINFORCING PER
TO CLEAR COLUMN VERTICAL BARS TYPICAL AT SHEAR WALLS PLAN DRAWING TITLE
CIP ID#7235.001

(NOT SHOWN) - TYP. ADD'L REINFORCING PER COLUMN


SCHEDULE (TYPICAL TOP & BOTTOM)
ADD'L REINFORCING PER
ENLARGED SHEAR WALL PLANS
(TYPICAL TOP & BOTTOM) PROVIDE #8 HOOKED
DOWEL @ EACH WALL
VERTICAL BAR - TYP.

SCALE
As indicated DATE
08/16/13

3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER

Author Checker
EQUAL EQUAL ~ DRAWN CHECKED
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS


SEE 2/S201 FOR SEE 2/S201 FOR
SECTION VIEW WATERPROOFING
EQUAL EQUAL WATERPROOFING
AND MUD SLAB AND MUD SLAB

TYPICAL DETAIL TYPICAL DETAIL S201


9/26/2013 8:30:51 AM

6 ADDITIONAL
3/4" = 1'-0"
MAT SLAB REINFORCING AT COLUMN 7 ADDITIONAL
3/4" = 1'-0"
MAT SLAB REINFORCING AT SHEAR WALL
DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
3' - 9" +/- 3' - 9" +/-
FOUNDATION ANCHOR
CENTERLINE, TYP.
CRANE FOUNDATION ANCHOR PER CONTRACTOR
CRANE (REMOVE PRIOR TO TOPPING INSTALLATION) CRANE FOUNDATION NOTES:
CENTERLINE
MAT SLAB PER PLAN SLOPED CONCRETE 1. TWO CRANES ARE TO BE LOCATED WITHIN BUILDING FOOTPRINT AS DETAILED ON THE PLANS.
TOPPING PER PLAN CRANES SHALL NOT BE RELOCATED WITHOUT WRITTEN AUTHORIZATION FROM THE ENGINEER.

2. CRANE FOUNDATIONS ARE CAST PRIOR TO THE MAT SLAB, AND MEET CRANE SUPPLIER'S
REINFORCING RECOMMENDATIONS. FOUNDATION IS BASED ON THE FOLLOWING INFO:
A. CRANE TYPE: MANITOWOC MD 485B
A.1 JIB CONFIGURATIONS L35 THRU L80
A.2 MAXIMUM HOOK HEIGHT = 215'-0"
B. CRANE MAX. TOTAL VERTICAL LOAD = 346 KIPS
C. MAX. HORIZONTAL FORCE = 56.7 KIPS
D. MAX. SLEWING MOMENT = 349 FT-KIPS
~

EQUAL
1' - 8 5/8"
E. MAX. OVERTURNING MOMENT = 5,922 FT-KIPS
6" 1' - 0" 6" SEE MAT SLAB F. T800A EXTERNAL CLIMBER SHALL BE STORED AT THE BASE OF THE CRANE. Lake|Flato
REINFORCING PLAN 311 Third Street, San Antonio , Texas 78205
T:210.227.3335
MAT SLAB THICKNESS PER PLAN

3. CONTRACTOR SHALL VERIFY DESIGN ASSUMPTIONS PRIOR TO CONSTRUCTING MAT www.LakeFlato.com


FOUNDATION.
Shepley Bulfinch Richardson & Abbott
4. IN-SERVICE WORKING CONDITIONS ARE RESTRICTED TO WIND SPEEDS NOT EXCEEDING 45 MPH. 2 Seaport Lane, Boston, Massachusetts 02210
REFER TO CRANE OPERATIONS MANUAL FOR INFORMATION REGARDING REDUCED WIND T:617.423.1700

EQUAL
SPEEDS FOR SLOWER TIMES TO SAFELY PLACE CRANE OUT-OF-OPERATION. www.ShepleyBulfinch.com
PROVIDE 2 #8's x 18'-6" EACH SIDE OF EACH 2 CONTINUOUS
FOUNDATION ANCHOR, TYP EACH WAY 2x12 SHEAR 5. A CONCRETE PEDESTAL MAY BE FORMED AROUND THE CONTINUOUS REBAR MAT TO
KEYS TYPICAL ESTABLISH A RAISED, FLAT AREA TO HELP LEVEL THE FOUNDATION ANCHORS.
REINFORCEMENT SHALL BE CONTINUOUS, DO NOT CUT BARS. CONCRETE PEDESTALS ARE
OPTIONAL AND SHALL NOT EXCEED 24" x 24" IN SIZE.
MAT SLAB TYPICAL
REINFORCING PER PLAN CONTINUOUS 6. INSTALLATION OF CONCRETE PEDESTALS, ADDITIONAL CRANE REINFORCING AND
WATERSTOP

EQUAL
FOUNDATION ANCHORS SHALL COMPLY WITH ALL CRANE SUPPLIER'S RECOMMENDATIONS.
PER ARCH'L PROJECT CONSULTANT

CONCRETE PEDESTALS
~ PROJECT CONSULTANT
SEE 2/S201 FOR WATERPROOFING
AND MUD SLAB
CRANE FOUNDATION PER PLAN LAP SPLICE
PER SCHEDULE
(TYPICAL) OF T
TE EX
A A

T
S

S
JOELLE S. ROSENTSWIEG

TYPICAL DETAIL

R
PR
89451

E
E
L

O
IC D
ENSE

N
F
E

1 MAT SLAB AT CRANE FOUNDATION S G


S N
ONAL E

3/4" = 1'-0"

SEE PLAN

T.O. ELEVATOR
PIT PER PLAN
SHEAR WALL PER PLAN SEE ELEVATOR
PIT TYP. DTL. SEE ARCH'L 1' - 6"

SEE PLAN - TYP.

ARCH'L
SEE
INTERMITTENT SHEAR KEY - SEE TYP. 1 1 09/26/2013 ADDENDUM #2
MAT SLAB DETAIL & SHEAR WALL NO. DATE DESCRIPTION
REVISIONS
LAP SPLICE

PER SCHEDULE
CMU WALL FRAMING SLOPED CONCRETE

LAP SPLICE
PER ARCH'L - TYP. PER SCHEDULE TOPPING PER PLAN -
CONCRETE SLOPED CONCRETE (TYPICAL) PLACED AFTER LEAVE-OUT
TOPPING BEYOND TOPPING PER PLAN SECTION INFILL

7 #3'S @ 4" O.C. -


TYP. EACH WAY

~
CMU DOWEL PER GENERAL NOTES
LAP SPLICE
PER SCHEDULE
LAP SPLICE
TYPICAL DETAIL NOTE: SUMP PIT
LOCATION PER ARCH'L.
PER SCHEDULE PROVIDE HOOKED

4 ELEVATOR SUMP PIT


RECESSED (TYP.) SEE MAT SLAB (TYP.) DOWEL @ EACH WALL
#4 SIDE BARS @ ELEVATOR PIT REINFORCING PLAN
12" O.C. MAX. - 4' - 0" VERTICAL BAR - MATCH
1 1/2" = 1'-0"
#8 L-BARS - SPLICE TYP. ALL FACES WALL BAR SIZE - SEE
~
MAT SLAB THICKNESS

WITH EACH SLAB TOP TYP. DOWEL SCHEDULE


BAR - TYP. ALL AROUND CONTINUOUS KEY PLAN
CONTINUOUS
PER PLAN

WATERSTOP HOOK
2x12 SHEAR KEY
PER ARCH'L PER SCHED. CITY OF AUSTIN
4' - 0"
T.O. ELEVATOR PIT CONT. TYPICAL T.O. ELEVATOR PIT
TYP. ELEV. PER PLAN WATERSTOP PER ELEV. PER PLAN
ARCH'L - TYP.
OWNER

LAP SPLICE
NEW CENTRAL LIBRARY
SEE MAT SLAB PER SCHEDULE ELEVATOR PIT REINF'G PER
REINFORCING PLAN (TYP.) CONTINUOUS 2x12 SHEAR KEY
TYPICAL DETAIL - MAT SLAB CIP ID#7235.001
AT ELEVATOR PIT W. CESAR CHAVEZ BLVD.
PROJECT
AUSTIN, TX
4' - 0" MIN.

MATCH SIZE & SPACING OF


SURROUNDING MAT SLAB LAP SPLICE
SUMP PIT REINFORCING PER SCHEDULE
L-BARS - SEE TYPICAL MAT SLAB FOUNDATION
BEYOND - SEE DETAIL - MAT SLAB AT
DETAILS
5' - 6"

5' - 6"
TYPICAL DETAIL (TYP.) ELEVATOR PIT
DRAWING TITLE
CIP ID#7235.001

4" MUD SLAB

SEE MAT SLAB


REINFORCING PLAN

~ SCALE
As indicated DATE
08/16/13
SEE 2/S201 FOR WATERPROOFING
3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

AND MUD SLAB AT ELEVATOR PIT JOB NUMBER

4" THICK FIBER REINFORCED WORKSLAB 4" MUD SLAB - TYP. CONTINUOUS WATERPROOFING - Author Checker
DRAWN CHECKED
NEW CENTRAL LIBRARY

SEE ARCH'L
PACKAGE 2 CONSTRUCTION DOCUMENTS
TYPICAL DETAIL
3 MAT SLAB AT ELEVATOR PIT & SHEAR WALL
2 MAT SLAB AT ELEVATOR PIT
3/4" = 1'-0"
3/4" = 1'-0"
S202
9/26/2013 8:31:00 AM

DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
TOPPING SLAB NOTES:
1. SEE PLAN AND GENERAL NOTES FOR THICKNESS OF
CONTROL JOINTS IN TOPPING
SLAB (T) AND REINFORCING.
PER PLAN - REF. TYPICAL DETAIL
2. REINFORCING TO BE LAPPED 30 BAR DIA. MINIMUM
OR TWO CROSSTIES FOR WIRE MESH. #4 x 4'-6" DIAGONAL TOP
3. SEE SPECIFICATIONS FOR SUPPORT OF REINFORCING. BAR AT EACH CORNER OF
4. SEE OTHER DETAILS FOR ADDITIONAL INFORMATION. COLUMN - TYPICAL

EDGE TO 1/8" RADIUS


EACH SIDE OF JOINT & FILL
WITH ELASTOMERIC SEALANT STOP SLAB REINF. P.
1/4" WIDE JOINT. AT JOINT TY
TOOL OR SAWCUT
FILL JOINT WITH 3"
ELASTOMERIC SEALANT - PROVIDE 2 #4 x 4'-0"

CLEAR
SEE SPECIFICATIONS DIAGONAL BARS

1 1/4"
VARIES

VARIES
3/4" DIA. x 2'-0"
SMOOTH BARS @ 18" IN TOP OF SLAB
T

T
T/4

3"
Lake|Flato

3" P.
311 Third Street, San Antonio , Texas 78205

T/2

TY
T:210.227.3335
4" www.LakeFlato.com
CUT AND REMOVE 4" WIDE
STRIP OF ALTERNATE WIRES MAT SLAB BELOW - Shepley Bulfinch Richardson & Abbott
OR BARS AT CONTROL JOINT SEE PLAN, GENERAL NOTES 2 Seaport Lane, Boston, Massachusetts 02210
AND SPECIFICATIONS
YP. 45°
T:617.423.1700
T www.ShepleyBulfinch.com
MAT SLAB BELOW - 3"
SEE PLAN, GENERAL NOTES
AND SPECIFICATIONS
CONSTRUCTION JOINT COLUMN PER PLAN PILASTER PER PLAN
CONSTRUCTION OR
CONTROL JOINT OR
RECESS IN TOPPING
(DETAIL APPLIES TO
NOTES: .
CONTROL JOINT (CJ) 1. LIMIT EACH TOPPING SLAB PLACEMENT TO AN AREA
THE CONTRACTOR HAS ADEQUATE EQUIPMENT AND 3"
T YP ROUND COLUMNS ALSO)
#4 DIAGONAL TOP BAR
AT EACH SIDE OF
PERSONNEL TO PLACE AND PROPERLY FINISH THE PILASTER - TYPICAL
NOTES:
CONCRETE. REPLACE CONTROL JOINTS WITH CONTROL JOINTS IN
1. JOINTS ARE REQUIRED IN TOPPING SLAB AT CORNERS
CONSTRUCTION JOINTS AS NEEDED. TOPPING PER PLAN - PROJECT CONSULTANT
A SPACING AS SHOWN IN THE TOPPING PLANS. NOTE:
2. IF METAL FORMS ARE USED, REMOVE THEM REF. TYPICAL DETAIL
2. SAW CUTS ARE TO BE MADE AS SOON AS SLAB FABRICATOR TO LOCATE
BEFORE POURING ADJACENT SLAB.
CAN SUPPORT WORKERS AND EQUIPMENT AND THESE BARS ON THE SHOP
BEFORE SHRINKAGE CRACKS OCCUR. DRAWINGS.
3. CLEAN JOINTS BEFORE FILLING WITH SEALANT.

PLAN VIEW PLAN VIEW PROJECT CONSULTANT

TYPICAL DETAIL TYPICAL DETAIL


TYPICAL DETAIL TYPICAL DETAIL
3 PILASTER CONTROL JOINT PATTERN 4 RE-ENTRANT CORNER REINFORCING
1 EXPOSED
NOT TO SCALE
TOPPING JOINTS 2 COLUMN
NOT TO SCALE
CONTROL JOINT PATTERN NOT TO SCALE NOT TO SCALE

~ ~ ~

~
4'-0" DIA PRECAST MAT SLAB TYPICAL
CONCRETE PIPE - REINFORCING PER PLAN
SEE PLUMBING
DRAWINGS

~
SYMM. ABOUT
DRAIN CENTERLINE
SLOPED TOPPING
SLAB PER PLAN
SEE PLUMBING
PROVIDE 4 ADD'L WALL PER ARCH'L - SEE
~

~
~

~
#4 x 4'-0" DRAWINGS FOR TOPPING SLAB TYPICAL DETAILS ON S200
DIAGONAL BARS FLOOR RAIN INFO. REINFORCEMENT PER FOR REINFORCED CMU
TO ENCLOSE DRAIN PLAN TO RUN
CONTINUOUS AROUND
DRAIN (SHOWN CUT HERE #3 HAIRPIN @ 12" O.C.
1' - 0" FOR CLARITY) SEE
SLOPE

~
SLOPE

~
ARCH'L
ARCH'L

SEE
4" MIN

VARIES
TOP OF
MAT SLAB T
PER PLAN

~
~

~
PROVIDE 4 ADD'L #9 4 #9's x 15'-0" BELOW
DIAGONAL TOP BARS BLOCKOUT AS SHOWN -

CLR.
TYP.
AROUND DRAIN TYP. EACH WAY LAP

3"
6" DEEP x SPLICE 2 CONT. #4's TOP

~
18" SQUARE LAP SPLICE
PER
BLOCKOUT PER SCHED. SCHEDULE
ADD'L DIAGONAL BARS TOP
NO. DATE DESCRIPTION
MAT SLAB BELOW - & BOTTOM & IN TOPPING
REVISIONS
SEE PLAN, GENERAL PER SECTION VIEW
NOTE:
FABRICATOR TO LOCATE DIAGONAL NOTES, TYPICAL DETAILS,
BARS ON THE SHOP DRAWINGS. AND SPECIFICATIONS

~ PROVIDE 4 ADD'L #4's x 12'-0" TOP DIAGONAL

~
PLAN VIEW BARS CENTERED ABOUT SUMP PIT
~ ~
TYPICAL DETAIL TYPICAL DETAIL SLOPED TOPPING PER PLAN 4'-0" CONCRETE PIPE - MAT SLAB TYPICAL REINFORCING
SEE PLUMBING DRAWINGS

5 FLOOR DRAIN IN TOPPING SLAB 6 RAISED CONCRETE CURB PER PLAN - PLACE CONTINUOUS
TOP OF MAT SLAB MAT BAR EACH SIDE OF SUMP PIT -
NOT TO SCALE NOT TO SCALE TYPICAL EACH WAY

PLAN
SEE
KEY PLAN

CITY OF AUSTIN

6'-0" - VERIFY W/ PLUMBING


PROVIDE 4 ADD'L #11 x 30'-0"
DIAGONAL BARS CENTERED
ABOUT SUMP PIT
OWNER

SEAL WITH BOLLARD PER ARCH'L


NEW CENTRAL LIBRARY

SEE PLAN
ELASTOMERIC
#8 DOWELS SPACED @ EACH MAT SLAB TOP BAR
SEALANT
SLOPED TOPPING
CIP ID#7235.001
W. CESAR CHAVEZ BLVD.
CONTINUOUS SHEAR KEY
1/2" EXPANSION JOINT
PROJECT
AUSTIN, TX
STND HOOK
WATERPROOFING PER ARCH'L

MAT SLAB FOUNDATION


PLAN

TOP OF
SEE

MAT SLAB
DETAILS
DRAWING TITLE
CIP ID#7235.001

1' - 0"
MIN

~ #8 BARS SPACED
AT EACH MAT BOTTOM BAR 1'-6" MIN
MAT SLAB BELOW #8'S @ 12" O.C.
EACH WAY - TYP.
4 x 1" DIAMETER
THREADED RODS
EPOXIED INTO MAT SLAB

4' - 6"
SCALE
As indicated DATE
08/16/13

HOOK 3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

JOB NUMBER
PER SCHED.
TYPICAL DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS


TYPICAL DETAIL
8' - 0"

7 BOLLARD ANCHORAGE INTO MAT SLAB SECTION VIEW


S203
8/14/2013 11:46:22 PM

3/4" = 1'-0"
TYPICAL DETAIL
8 SECTION
3/4" = 1'-0"
AT CONCRETE PIPE SUMP
DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
BASEMENT CONCRETE WALL SCHEDULE
NORTHWEST WALLS WALLS
NORTH WALL WEST WALL WEST WALL
BASEMENT WALL: NORTH WALL AREAWAY WEST WALL AT SOUTHWEST SOUTH WALL EAST WALL AT EAST
AT ELEVATOR BELOW RAMP AT MASONRY LEDGE BASEMENT WALL NOTES:
WALLS ENTRANCE ENTRANCE
1. SEE TYPICAL WALL DETAILS FOR ADDITIONAL SPLICE INFORMATION
AND REINFORCEMENT NOT SHOWN HERE.
ON GRID A, ON GRID H, ON GRID Y3,
FROM GRID 8 FROM GRID 6 FROM GRID X3 2. SEE GENERAL NOTES FOR CLEAR COVER AND OTHER CONCRETE
REQUIREMENTS NOT SHOWN HERE.
ON GRID 1, ON GRID 1, ON GRID A, ON GRID A, ON GRID A, ON GRID A, TO GRID 11; ON GRID 11, TO GRID 11; TO GRID 4.8;
LOCATION: FROM GRID A BETWEEN GRID D FROM GRID 1 FROM GRID 2 FROM GRID 4 FROM GRID 5 FROM GRID B 3. SEE ARCHITECTURAL FOR CONTINUOUS WATERPROOFING BEHIND
TO GRID J AND GRID E TO GRID 2 TO GRID 4 TO GRID 5 TO GRID 8 ON GRID 11, TO GRID H ON GRID Y3, ON GRID H, EXTERIOR WALLS AND AT WALL CONSTRUCTION JOINTS.
FROM GRID A FROM GRID X1 FROM GRID 4.8
TO GRID B TO GRID X3 TO GRID 6

TYPE A TYPE C TYPE C TYPE A TYPE A TYPE A TYPE D TYPE B TYPE B TYPE D

TYPE TYPE TYPE


3‐STORY 3‐STORY 2‐STORY 2‐STORY Lake|Flato
FLOOR LEVEL WALL TYPE: 3‐STORY A A A 2‐STORY 2‐STORY 311 Third Street, San Antonio , Texas 78205
EXTERIOR EXTERIOR EXTERIOR EXTERIOR
EXTERIOR 3‐STORY 3‐STORY 3‐STORY EXTERIOR EXTERIOR T:210.227.3335
CANTILEVER CANTILEVER CANTILEVER CANTILEVER www.LakeFlato.com
WALL EXTERIOR EXTERIOR EXTERIOR WALL WALL
WALL WALL WALL WALL
WALL WALL WALL Shepley Bulfinch Richardson & Abbott
2 Seaport Lane, Boston, Massachusetts 02210
LEVEL 2 DETAIL(S) 1/S212 1/S212 1/S212 1/S212 1/S212 1/S212 T:617.423.1700
www.ShepleyBulfinch.com

THICKNESS (T) 18" 24" 24" 18" 18" 14"

VERTICAL REINF. #7 @ 8" O.C. #7 @ 12" O.C. #7 @ 8" O.C. #7 @ 8" O.C. #7 @ 8" O.C. #7 @ 8" O.C.


LEVEL 1
HORIZONTAL REINF. #4 @ 6" O.C. #7 @ 6" O.C. #7 @ 6" O.C. #4 @ 6" O.C. #4 @ 6" O.C. #4 @ 6" O.C.

DETAIL(S) 1/S212 1/S212 1/S212 1/S212 PROJECT CONSULTANT

THICKNESS (T) 21" 24" 24" 21" 21" 24" 24" 18" 18" 18"

VERTICAL REINF. #7 @ 8" O.C. #7 @ 12" O.C. #7 @ 8" O.C. #7 @ 8" O.C. #7 @ 8" O.C. #7 @ 8" O.C. #8 @ 6" O.C. #7 @ 12" O.C. #7 @ 12" O.C. #7 @ 12" O.C.
LEVEL P1
HORIZONTAL REINF. #4 @ 6" O.C. #7 @ 6" O.C. #7 @ 6" O.C. #4 @ 6" O.C. #4 @ 6" O.C. #5 @ 6" O.C. #8 @ 6" O.C. #4 @ 6" O.C. #4 @ 6" O.C. #4 @ 6" O.C. PROJECT CONSULTANT

DETAIL(S)

THICKNESS (T) 24" 24" 24" 24" 24" 24" 24" 18" 18" 18"

VERTICAL REINF. #7 @ 8" O.C. #7 @ 12" O.C. #7 @ 8" O.C. #7 @ 8" O.C. #7 @ 8" O.C. #7 @ 8" O.C. #8 @ 6" O.C. #7 @ 12" O.C. #7 @ 12" O.C. #7 @ 12" O.C.
LEVEL P2
HORIZONTAL REINF. #5 @ 6" O.C. #7 @ 6" O.C. #7 @ 6" O.C. #5 @ 6" O.C. #5 @ 6" O.C. #5 @ 6" O.C. #8 @ 6" O.C. #4 @ 6" O.C. #4 @ 6" O.C. #4 @ 6" O.C.

DETAIL(S)

NOTES:

SEE TOP OF WALL DETAILS SEE TOP OF WALL DETAILS

T.O.S.C. EL. T.O.S.C. EL.

NOTE: VERTICAL BARS MAY RUN


CONTINUOUS AT CONTRACTOR'S OPTION.
SCHEDULED BARS -
TOP STORY

SCHEDULED BARS -
TOP STORY
PER SCHED. TYPICAL

PER SCHED. TYPICAL


LAP SPLICE
PER SCHED. TYPICAL

SEE TOP OF WALL DETAILS

LAP SPLICE
LAP SPLICE

SEE TOP OF WALL DETAILS NO. DATE DESCRIPTION


REVISIONS
T.O.S.C. EL. T.O.S.C. EL. T.O.S.C. EL. T.O.S.C. EL.
PER SCHED. TYPICAL

SPLICE BAR, SAME


SIZE & SPACING
LAP SPLICE

AS INTERMEDIATE
STORY REINF. NOTE: HORIZ. REINF. NOT
SHOWN FOR CLARITY - TYP.
SCHEDULED BARS - SCHEDULED BARS -
INTERMEDIATE STORY TOP STORY

SCHEDULED BARS -
INTERMEDIATE STORY

SCHEDULED BARS -
TOP STORY
PER SCHED. TYPICAL

PER SCHED. TYPICAL

KEY PLAN
PER SCHED. TYPICAL

PER SCHED. TYPICAL

PER SCHED. TYPICAL

CITY OF AUSTIN
LAP SPLICE

LAP SPLICE

PER SCHEDULE
LAP SPLICE

LAP SPLICE

LAP SPLICE

LAP SPLICE
T.O.S.C. EL. T.O.S.C. EL. T.O.S.C. EL. T.O.S.C. EL. OWNER

NEW CENTRAL LIBRARY


SCHEDULED BARS - SPLICE BAR, SAME CIP ID#7235.001
PER SCHED. TYPICAL

PER SCHED. TYPICAL

BOTTOM STORY SIZE & SPACING AS W. CESAR CHAVEZ BLVD.


BOTTOM STORY REINF'G
LAP SPLICE

LAP SPLICE

PROJECT
AUSTIN, TX
SCHEDULED BARS -
SPLICE BAR, SAME SIZE BOTTOM STORY
SCHEDULED BARS -
& SPACING AS BOTTOM
STORY REINF'G BOTTOM STORY SCHEDULED BARS - BASEMENT WALL SCHEDULE
BOTTOM STORY
& SECTIONS
PER SCHEDULE TYPICAL

PER SCHEDULE TYPICAL

PER SCHEDULE TYPICAL

DRAWING TITLE
CIP ID#7235.001

PER SCHEDULE
LAP SPLICE

LAP SPLICE

LAP SPLICE

LAP SPLICE

T.O.S.C. EL. T.O.S.C. EL. T.O.S.C. EL. T.O.S.C. EL.

DOWELS PER As indicated 08/16/13


DOWEL SCHEDULE DOWELS PER DOWELS PER
SCALE DATE

DOWEL SCHEDULE DOWEL SCHEDULE DOWELS PER


3860
C:\Users\tamis\Documents\ACL_CENTRAL_STRUCT - 1_tamis.rvt

DOWEL SCHEDULE JOB NUMBER

DRAWN
Author CHECKED
Checker
NEW CENTRAL LIBRARY

PACKAGE 2 CONSTRUCTION DOCUMENTS

TYPE A
TYPICAL 3-STORY EXTERIOR WALL
TYPE B
TYPICAL 2-STORY EXTERIOR WALL
TYPE C
3-STORY EXTERIOR CANTILEVER WALL
TYPE D
2-STORY EXTERIOR CANTILEVER WALL
S211
8/14/2013 11:46:24 PM

TYPICAL DETAIL
1 BASEMENT
3/8" = 1'-0"
WALL TYPES AND VERTICAL REINFORCEMENT LAYOUT
DRAWING NUMBER

THE ORIGINAL OF THIS DRAWING IS 30" X 42". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY.
Shepley Bulfinch
A Joint Venture
LAP SPLICE LENGTH LAP SPLICE LENGTH
10" PER SCHEDULE (TYPICAL)
MASONRY VENEER PER ARCH'L PER SCHEDULE (TYPICAL)

MASONRY VENEER PER ARCH'L

3"
LAP SPLICE LENGTH LAP SPLICE LENGTH "T"/3 "T"/3 "T"/3

3 1/2"
PER SCHEDULE (TYPICAL) PER SCHEDULE (TYPICAL)

CONTINUOUS KEY AND ELEVATION CONTINUOUS KEY AND SLAB PER PLAN
WATERSTOP, REFER WATERSTOP, REFER REINFORCING
TO SPECIFICATIONS SEE PLAN TO SPECIFICATIONS TO BE
3/4" CHAMFER - CONT. CONTINUOUS
LEVEL 2 TYP. @ EXPOSED LEVEL 2 WATERSTOP THROUGH JOINT
PROVIDE STD. HOOK FLOOR FRAMING EDGES FLOOR FRAMING PER ARCH'L OR PROVIDE
PER DOWEL SCH. 2%
LAP SPLICE BAR

1 1/2"
MIN

PER SCHEDULE
BEAM DEPTH

3" 3"
Lake|Flato

1' - 0"
LAP SPLICE LENGTH
1' - 0"

1' - 0"

1' - 0"
311 Third Street, San Antonio , Texas 78205

LAP SPLICE LENGTH


#3 HAIRPIN SPACED #3 HAIRPIN SPACED #3 HAIRPIN SPACED #3 HAIRPIN SPACED PROVIDE SPLICE BARS AT

PER SCHEDULE
T:210.227.3335

PER SCHEDULE
EACH BEAM TOP BAR - SIZE
LAP SPLICE LENGTH

WITH WALL VERTICAL WITH WALL VERTICAL WITH WALL VERTICAL WITH WALL VERTICAL www.LakeFlato.com
TO MATCH BEAM BARS
PER SCHEDULE

REINFORCING BARS REINFORCING BARS REINFORCING BARS REINFORCING BARS CONTINUOUS SHEAR KEY -
Shepley Bulfinch Richardson & Abbott
TYPICAL 2 Seaport Lane, Boston, Massachusetts 02210
T:617.423.1700
BASEMENT WALL PER PLAN www.ShepleyBulfinch.com
WALL REINFORCING
PER SCHEDULE WALL REINFORCING WALL REINFORCING WALL REINFORCING

1' - 0"
PER SCHEDULE PER SCHEDULE PER SCHEDULE PERPENDICULAR
#3 HAIRPIN SPACED
WITH WALL VERTICAL BEAM PER PLAN
PROVIDE HOOK

LENGTH PER SCH.


REINFORCING BARS

DEVELOPMENT
"T" - SEE

LAP SPLICE LENGTH


INSIDE

PER SCHEDULE
OUTSIDE SAME SIZE & OUTSIDE INSIDE WALL SCHED.
FACE OF WALL FACE OF WALL SPACING AS FACE OF WALL FACE OF WALL
OUTER FACE PROJECT CONSULTANT
VERTICAL BARS NOTE: THIS DETAIL APPLIES TO HORIZONTAL AND
WALL REINFORCING VERTICAL CONSTRUCTION JOINTS IN PERIMETER
PER SCHEDULE BASEMENT CONCRETE WALLS.
OUTSIDE INSIDE
FACE OF WALL FACE OF WALL
INSIDE
FACE OF WALL TYPICAL DETAIL PROJECT CONSULTANT

WALL BELOW FLOOR FRAMING FREESTANDING WALL WALL BELOW BEAM FRAMING WALL BELOW SLAB
M

Potrebbero piacerti anche