Sei sulla pagina 1di 4

INSTRUCTION FOR SETTING

SLOWDOWN AND STOP LASER TRIGGER KEYENCE

SET  

DISP   MODE  

First step

1. Connect laser

Display : Start Config.

2. Press MODE

Display : Select I/O


OUT1+OUT2

3. Press MODE

Display : Select output


NPN

4. Press SET
5. Press MODE and change to PNP
6. Press SET
7. Press MODE

Display : End Config.

8. Press SET

  Page 1 of 4

 
Second step

1. Press MODE for 3 second until

Display : Menu

2. Press MODE

Display : Response time


25ms

3. Press MODE

Display : Output1 logic


N.O

4. Press SET
5. Press MODE

Display : Output1 logic


N.C

6. Press SET
7. Press MODE

Display : Output1 mode


Standard

8. Press MODE

Display: Output1 timer


Timer off

9. Press MODE

Display : Output2 logic


N.O

10.Press SET
11.Press MODE

Display : Output2 logic


N.C

12.Press SET

Display : Output2 mode


Stability

  Page 2 of 4

 
13.Press SET
14.Press MODE 2 times

Display: Output2 mode


Standard

15.Press SET
16.Press MODE

Display : Output2 timer


Off

17.Press MODE 2 times

Display : End

18.Press MODE

Display : Saving

Third step

1. Press MODE

Display: Out 1 (is for stop distance)


Out 2 (is for slowdown distance)

Check if Out 1 is already selected otherwise press MODE button again to select
Out 1

2 Press SET. You should see the distance 70 blinking

3 While the distance 70 is blinking, press MODE button many times to increase
the distance 70 up to 80

4 When you finished, release the MODE button and leave the new distance 80
blinking for some seconds until it becomes steady.
The new distance 80 is confirmed

2. Press MODE again and select Out 2 by pressing again MODE (if Out 2 is not
selected)

3. Follow the same steps as before to set the Out 2 at 800

-----------------------------------------------------------------------------------------
NOTE: Press MODE and then SET 5 times to reset the Keyence laser trigger

  Page 3 of 4

 
INSTRUCTION FOR SETTING
LASER TRIGGER KEYENCE FOR PALLET DISTANCE

1. Connect laser

Display : Start Config

2. Press MODE

Display : Select I/O


OUT1+OUT2

3. Press SET
4. Press MODE

Display : Select I/O


INPUT+OUT1

5. Press SET
6. Press MODE 2 times

Display : Select Output


NPN

7. Press SET
8. Press MODE and change to PNP
9. Press SET
10.Press MODE
11.Press SET
12.Press MODE and set 1000 by pressing up/down arrow key

  Page 4 of 4

Potrebbero piacerti anche