Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Hardware Description
Compiled by Thunder-link.com
No part of this document may be reproduced or transmitted in any form or by any means
without prior written consent of Huawei Technologies Co., Ltd.
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their
respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between
Huawei and the customer. All or part of the products, services and features described in this
document may not be within the purchase scope or the usage scope. Unless otherwise
specified in the contract, all statements, information, and recommendations in this document
are provided "AS IS" without warranties, guarantees or representations of any kind, either
express or implied.
The information in this document is subject to change without notice. Every effort has been
made in the preparation of this document to ensure accuracy of the contents, but all
statements, information, and recommendations in this document do not constitute a
warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
TTX
Contents
3.2.16.16 TTX
3.2.16.16.1 Version Description
3.2.16.16.2 Update Description
3.2.16.16.3 Application
3.2.16.16.4 Functions and Features
3.2.16.16.5 Working Principle and Signal Flow
3.2.16.16.6 Front Panel
3.2.16.16.7 Valid Slots
3.2.16.16.8 Physical and Logical Ports
3.2.16.16.9 Parameters Can Be Set or Queried by NMS
3.2.16.16.10 TTX Specifications
3.2.27.9.4 Functions and Features
3.2.16.16 TTX
TTX: 10 x 10G tributary service processing board
Version Description
The available functional versions of the TTX board are TN54 and TN55.
Update Description
This section describes the hardware updates in V100R007C02 and later
versions as well as the reasons for the updates. Any product versions
that are not listed in the document means that they have no hardware
updates.
Application
As a type of tributary board, the TTX board converts between ten
channels of 10GE LAN/10GE WAN/STM-64/OC-192/OTU2/OTU2e/FC800/FC1200
optical signals and ten channels of ODU2/ODU2e/ODUflex electrical
signals through cross-connection.
Front Panel
There are indicators and interfaces on the front panel of the TTX
board.
Valid Slots
One slot houses one TTX board.
TTX Specifications
Specifications include optical specifications, dimensions, weight,
and power consumption.
TN54T V100R007C02 N Y N Y Y N N N
TX
TN55T V100R009C00SP N Y N Y Y N N N
TX C100
NOTE:
For an enhanced OptiX OSN 8800 T64 subrack, the TTX board must work with
TNK2USXH+TNK2UXCT boards.
For an enhanced OptiX OSN 8800 T32 subrack, the TTX board must work with the
TN52UXCH or TN52UXCM board.
For an OptiX OSN 8800 T16 subrack, the TTX board must work with the TN16UXCM
board.
Variants
The TN54TTX/TN55TTX board has only one variant: TN54TTX01/TN55TTX01.
TN54TT N N N N N N
X
TN55TT Y Y Y Y Y Y
X
Specification:
The specifications vary with the version of the board that you use.
For details, see TTX Specifications.
Substitution Relationship
TN55TTX None -
Added the TN55TTX board. Compared with the TN54TTX board, the TN55TTX
board newly supports:
Added the TN54TTX board. The TN54TTX board is added to process 10 x 10G
tributary services.
Parent topic: TTX
3.2.16.16.3 Application
As a type of tributary board, the TTX board converts between ten
channels of 10GE LAN/10GE WAN/STM-64/OC-192/OTU2/OTU2e/FC800/FC1200
optical signals and ten channels of ODU2/ODU2e/ODUflex electrical
signals through cross-connection.
For the position of the TTX board in the WDM system, see Figure 1.
Figure 1 Position of the TTX board in the WDM system
NOTE:
Only the TN55TTX supports FC800, FC1200, OTU2 and OTU2e services.
The cross-connection of ODUflex signals is supported only by the TN55TTX board.
OTU2e/FC1200 ODU2e
Table 1 Client-side service mapping path supported by the board
FC800 ODU2/ODUflex
OTN function Supports the OTN frame format and overhead processing by
referring to the ITU-T G.709. The mapping process is
compliant with ITU-T G.709.
ODU2/ODUflex layer: supports the PM and TCM function, and
PM and TCM non-intrusive monitoring functions.
OTU2 layer: supports the SM function.
LPT function The board supports the LPT function only when the client-
side service type is 10GE LAN.
Alarm and Monitors BIP8 bytes (Bursty mode) to help locate line
performance failures.
event Monitors parameters such as the bias current,
monitoring temperature, and optical power of the laser.
Monitors OTN alarms and performance events.
Supports the remote monitoring (RMON) of Ethernet
services (10GE LAN).
ALS function Supports the ALS function on the client side when client
services are non-OTN services.
Physical clock TN54TTX: When the board receives 10GE LAN services and the
port mapping is Bit Transparent Mapping (11.1 G) on its
client side, the board can support synchronous Ethernet
transparent transmission instead of synchronous Ethernet
processing.
Table 1 Functions and features of the TTX board
TN55TTX: When the board receives 10GE LAN services and the
port mapping is Bit Transparent Mapping (11.1 G) on its
client side, the board can support synchronous Ethernet
transparent transmission instead of synchronous Ethernet
processing. When the board receives 10GE LAN services and
the port mapping is MAC Transparent Mapping (10.7 G) on its
client side, the board can support synchronous Ethernet
processing instead of synchronous Ethernet transparent
transmission.
Electrical- Supported
layer ASON
Port MTU The value ranges from 1518 to 9600, in bytes. That is, the
maximum size of the supported Jumbo frame is 9600 bytes.
NOTE:
Only the TN55TTX supports port MTU.
when Port Mapping is set to Bit Transparent Mapping(11.1G), Maximum
Packet Length is unavailable on the U2000.
Outloop Supported
NOTE:
Only the TN55TTX board supports FC encapsulation and mapping module, client-side
OTN processing module and the IEEE 1588v2 module.
The cross-connection of ODUflex signals is supported only by the TN55TTX board.
Signal Flow
The transmit and the receive directions are defined in the signal
flow of the TTX board. The transmit direction is defined as the
direction from the client side of the TTX to the backplane, and the
receive direction is defined as the reverse direction.
Transmit direction
Receive direction
Module Function
Client-side optical module
The module consists of a client-side receiver and a client-side
transmitter.
NOTE:
FC800 services can be mapped into ODU2/ODUflex payload area and FC1200
services can be mapped into ODU2e payload area.
Cross-connect module
Indicators
Four indicators are present on the front panel:
Interfaces
Table 1 lists the type and function of each interface.
Table 1 Types and functions of the interfaces on the TTX board
Table 1 Mapping between the physical ports on the TTX board and the
port numbers displayed on the NMS
TX1/RX1 3
TX2/RX2 4
TX3/RX3 5
TX4/RX4 6
TX5/RX5 7
TX6/RX6 8
TX7/RX7 9
TX8/RX8 10
TX9/RX9 11
TX10/RX10 12
NOTE:
The port number displayed on the U2000 indicates a pair of physical optical ports.
One transmits signals and the other receives signals.
Logical Ports
Figure 1 shows the port diagrams of the TTX board. Table 2 describes
the meaning of each port.
Figure 1 Port diagram of the TTX
NOTE:
The cross-connection of ODUflex signals is supported only by the TN55TTX board.
Service processing
module
Channel Use Used, Unused The Channel Use Status parameter sets the
Status Default: occupancy status of the current channel of a
Used board.
When this parameter is set to Unused for a
port, service alarms reported for this port
will be masked and the function for
automatically disabling service-affecting
settings is invalid for the port.
This parameter is set to Used by default. Set
this parameter to Unused when the current
channel is not used for the moment.
Laser Status Off, On The Laser Status parameter sets the laser
Default: Off status of a board.
See Laser Status (WDM Interface) for more
information.
Service Mode Client Mode, When the board is enabled to receive an OTN
OTN Mode service on the client side, set this parameter
Default: to OTN Mode. For any other client service
Client Mode types, set this parameter to Client Mode.
NOTE:
Only the TN54TTX supports this parameter.
Hold-off Time 0s, 100ms, Specifies the hold-off time for automatically
of Automatic 200ms, disabling lasers.
Laser 300ms, With ALS enabled, the hold-off time is a time
Shutdown 400ms, period from the point when the system detects
500ms, service interruption to the point when ALS
600ms, automatically shuts down the related lasers.
700ms,
800ms,
900ms, 1s,
1100ms,
1200ms,
1300ms,
1400ms,
1500ms,
1600ms,
1700ms,
1800ms,
1900ms, 2s
Default: 0s
Hold-off Time 0s, 100ms, Specifies the hold-off time for automatically
of Automatic 200ms, enabling lasers.
Laser Turn-On 300ms, With ALS enabled, the hold-off time is a time
400ms, period from the point when the system detects
500ms, service recovery to the point when ALS
600ms, automatically enables the related lasers.
700ms,
800ms,
900ms, 1s,
1100ms,
1200ms,
1300ms,
1400ms,
1500ms,
1600ms,
1700ms,
Table 1 TTX parameters
1800ms,
1900ms, 2s
Default: 0s
FEC Mode FEC The FEC Mode parameter sets the FEC mode of
Default: FEC the current optical interface.
FEC Mode of two interconnected boards must be
the same.
This parameter is available only when you set
FEC Working State to Enabled.
NOTE:
Only the TN55TTX supports this parameter.
This parameter can be set only when Service Type is set to
OTU2 or OTU-2E.
Max. Packet 1518 to 9600 Sets and queries the maximum packet length
Length Default: supported by a board and is applicable to the
9600 boards supporting Ethernet services.
For a 10GE LAN service, when the port mapping
mode is Bit Transparent Mapping(11.1G) or Bit
Transparent Mapping(10.7G), data packets will
be transparently transmitted if their lengths
exceed Max. Packet Length. When the port
mapping mode is MAC Transparent
Mapping(10.7G), data packets will be discarded
if their lengths exceed Max. Packet Length.
Table 1 TTX parameters
NOTE:
Only the TN55TTX supports this parameter.
For the TN55TTX, when Port Mapping is set to Bit
Transparent Mapping(11.1G), Maximum Packet Length is
unavailable on the U2000.
PRBS Test Disabled, The PRBS Test Status parameter sets the
Status Enabled pseudo-random binary sequence (PRBS) test
Default: status of a board.
Disabled The PRBS test belongs to the fault diagnosis
function and affects channel services. After
the PRBS test is started, the services on the
corresponding port are interrupted.
Different boards support different optical
interface channels. After the command of
enabling the PRBS test is issued, an error is
returned in case the optical interface
channels do not support the PRBS test.
See Configuring the PRBS Test for more
information.
NOTE:
This parameter is supported only by the TN55TTX.
Port Working ODU2 non- Specifies the working mode of the interface on
Mode convergence the board depending the actual application
mode scenario and service mapping path.
(OTU2/Any- NOTE:
>ODU2), Only the TN55TTX supports this parameter.
ODUflex non-
convergence
mode (Any-
>ODUflex),
None(not for
ports)
Default:
ODU2 non-
convergence
mode
(OTU2/Any-
>ODU2)
NOTE:
Margins exist between the default input power low threshold and the receiver
sensitivity and between the default input power high threshold and the overload
point. These margins ensure that the system can report an input power low or high
alarm before the actual input power reaches the receiver sensitivity or overload
point.
NOTE:
10 Gbit/s Multirate-10 km-SFP+, 10 Gbit/s Multirate-40 km-SFP+ and 10 Gbit/s
Multirate-80 km-SFP+ optical module can be used to access OC-192, STM-64, 10GE WAN,
or 10GE LAN, OTU2, OTU2e, FC800 and FC1200signals.
Target km 10 40 80
transmission
distance
Minimum dB 6 8.2 9
extinction
ratio
NOTE:
10G BASE-SR-0.3 km-SFP+, 10G BASE-LR-10 km-SFP+, 10G BASE-ER/EW-40 km-SFP+
optical module can be used to access 10GE LAN, 10GE WAN, FC800 and FC1200
signals.
10G BASE-ZR-80 km-SFP+ optical module can be used to access 10GE LAN and10GE WAN
signals.
source type
Minimum dB 3 3.5 3 9
extinction
ratio
mask
Target km 10 10
transmission
distance
Mechanical Specifications
Dimensions of front panel (H x W x D): 264.6 mm (10.4 in.) x 25.4
mm (1.0 in.) x 220 mm (8.7 in.)
Power Consumption
a: The maximum power consumption is the power consumed by the board when it
works normally under the highest ambient temperature.
Ethernet services.
Cross-connects a maximum of 1.28 Tbit/s VC-4 signals.
Supports hybrid transmission of the above-mentioned
services with the maximum cross-connect capacity of
3.2 Tbit/s.
General OptiX OSN 8800 T32 subrack:
Cross-connects a maximum of 2.56 Tbit/s ODUk (k = 0,
1, 2, 2e, 3, 4 or flex) signals.
Performs packet switching of a maximum of 640 Gbit/s
Ethernet services.
Cross-connects a maximum of 1.28 Tbit/s VC-4 signals.
Supports hybrid transmission of the above-mentioned
services with the maximum cross-connect capacity of
2.56 Tbit/s.
Electrical-layer Supported
ASON