ULTRASONIC LEVEL TRANSMITTER

With PC Programming
OMEGA’s LVU2700 ultrasonic
LVU2700 Series level transmitter provides
continuous level measurement
up to 10 m (32.8') with a
4 to 20 mA signal output,
and is configured via free
software download and a
USB adaptor. This non-
contact liquid level sensor is
U4  Measurement Ranges ideally suited for corrosive,
from 3 to 10 m (9.8 to 32.8') ultrapure, sticky or dirty liquids,
and is broadly selected for bulk
UA  uto Adaptive Filters storage, day tank, lift stations and
Enable Plug and Play process tank level applications.
Operation
UF  ast and Easy
Configuration Specifications
Via Free Software Range
LVU2710: 10 cm to 3 m (4" to 9.8')
Download and LVU2718: 20 cm to 5.5 m (8" to 18.0')
USB Adaptor LVU2726: 20 cm to 8 m (8" to 24.6')
UN  arrow 5 or 7.6 cm (2 or 3") LVU2732: 20 cm to 10 m (8" to 32.8')
Beam Width and Short Accuracy: ±0.2% of range
Resolution LVU2710
10 or 20 cm (4 or 8") LVU2710: 0.5 mm (0.019")
Dead Band LVU2718: 1 mm (0.039")
U PVDF Transducer LVU2726/32: 2 mm (0.079") Signal Invert: 4 to 20 mA or 20 to 4 mA
Dead Band Signal Fail-Safe: 4 mA, 20 mA, 21 mA,
and NEMA 4X (IP65) LVU2710: 10 cm (4") 22 mA or hold last
Polycarbonate Enclosure LVU2718/26/32: 20 cm (8") Process Temp: -20 to 60ºC
U Automatic Temperature Beam Width (-4 to 140ºF)
Compensation for LVU2710: 5 cm (2") Temp Comp: Automatic
LVU2718/26/32: 7.6 cm (3") Ambient Temp: -35 to 60ºC
Accurate Measurement Configuration: USB PC Windows® (-31 to 140ºF)
Dimensions: USB 2.0 Memory: Non-volatile. Pressure: Maximum Working
mm (inch) 104 (4.1) 133 (5.2) via our
The level sensor is configurable Pressure = 2 bar (30 psi)
96 (3.8) free PC software download and USB 138 Enclosure Rating: NEMA 4X (IP65)
adaptor. The sensors are offered with (5.5) Enclosure Material: Polycarbonate
133 (5.2)
and without USB connectors. Connectors Trans Material: PVDF
100 can be used to configure any compatible 100 Cable Jacket Material: Polyurethane
(3.9) 2 NPT (4)
level product. Download
(2 G
your free copy Cable Type: 4-conductor, shielded
88
at: omega.com/ftp
optional) (3.4) Process Mount:
133 49 Supply Voltage: 24 Vdc (loop) 69 LVU2710: 1 NPT (1" G optional)
1 NPT
104 (4.1)
96 (3.8)
(5.2)
62
(1.9)
Consumption:
133 (5.2) (1" G 0.5 W
optional)
32Loop Resistance: 500 Ω @ 24 Vdc
(2.7) LVU2718/26/32: 2 NPT (2" G optional)
Mount Gasket: FKM
K
(2.4) (1.25) 138 Classification: General purpose
Signal Output: 4 to 20 mA, two-wire
(5.5)
133 (5.2)
100
(3.9) 2 NPT
To Order
100
(4) Visit omega.com/lvu2700 for Pricing and Detail
(2 G
optional)
LVU2710
Model
88 No.
(3.4)
Description
49 LVU2710
69
Ultrasonic level transmitter with USB connector, range 3 m (9.8')
(1.9) 1 NPT
(1" G (2.7)
LVU2718 Ultrasonic level transmitter with USB connector, range 5.5 m (18')
62 32 optional) LVU2726 Ultrasonic level transmitter with USB connector, range 8 m (26.2')
(2.4) (1.25)
LVU2732 Ultrasonic level transmitter with USB connector, range 10 m (32.8')
133 (5.2)
LVU2710-B* Ultrasonic level transmitter, range 3 m (9.8')
LVU2718-B* Ultrasonic level transmitter, range 5.5 m (18')
138
(5.5) LVU2726-B* Ultrasonic level transmitter, range 8 m (26.2')
133 (5.2)
LVU2732-B* Ultrasonic level transmitter, range 10 m (32.8')
0 100
(4) LVCN414-USB USB connector (1 required for -B models, sold separately)*
) 2 NPT
(2 G 88 Comes complete with software, mounting gasket and operator’s manual.
optional) (3.4) For units with G threads add "-G" to model number, for additional cost.
49 69 Configuration software for programming available free at omega.com/ftp
(1.9) 1 NPT
(1" G
LVU2718/26/32 (2.7) Ordering Example: LVU2710, level transmitter with 4 to 20 mA output and USB connector,
62 32 optional) 1 NPT, 3 m (9.8') range.