Sei sulla pagina 1di 5

Escalera 2 19-Mar-18

Site 1 / Building 1 / Storey 1 / Stairway / Room summary

Stairway

Clearance height: 5.000 m, Reflection factors: Ceiling 70.0%, Walls 67.2%, Floor 70.3%, Light loss factor: 0.80

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane Perpendicular illuminance (adaptive) [lx] 184 (≥ 150) 2.64 310 0.01 0.01
Height: 0.000 m, Wall zone: 0.000 m

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

3 Philips Lighting - DN130B D165 1xLED10S/840 1192 11.6 102.8

4 Philips Lighting - DN131B D217 1xLED20S/840 2109 22.0 95.9

Total via all luminaires 12012 122.8 97.8

Lighting power density: 6.14 W/m² = 3.34 W/m²/100 lx (Floor area of room 20.00 m²)

The energy consumption quantities refer to the lights planned for the room without taking into account light scenes and their dimming levels.
Consumption: 140 kWh/a of maximum 750 kWh/a

Page 1
Escalera 2 19-Mar-18

Site 1 / Building 1 / Storey 1 / Stairway / Luminaire layout plan

Stairway

Philips Lighting DN130B D165 1xLED10S/840

No. X [m] Y [m] Mounting height [m]


1 3.574 0.842 5.000
2 3.506 2.858 5.000
3 3.438 4.487 5.000

Philips Lighting DN131B D217 1xLED20S/840

No. X [m] Y [m] Mounting height [m]


4 0.700 3.300 5.113
5 2.058 3.292 5.113
6 0.608 1.654 5.113
7 2.058 1.592 5.113

Page 2
Escalera 2 19-Mar-18

Site 1 / Building 1 / Storey 1 / Stairway / Luminaire parts list

Stairway
Quantity Luminaire (Luminous emittance)
3 Philips Lighting - DN130B D165 1xLED10S/840
Luminous emittance 1
Fitting: 1xLED10S/840/-
Light output ratio: 91.72%
Lamp luminous flux: 1300 lm
Luminaire luminous flux: 1192 lm
Power: 11.6 W
Luminous efficacy: 102.8 lm/W

Colorimetric data
1xLED10S/840/-: CCT 3000 K, CRI 100

4 Philips Lighting - DN131B D217 1xLED20S/840


Luminous emittance 1
Fitting: 1xLED20S/840/-
Light output ratio: 87.87%
Lamp luminous flux: 2400 lm
Luminaire luminous flux: 2109 lm
Power: 22.0 W
Luminous efficacy: 95.9 lm/W

Colorimetric data
1xLED20S/840/-: CCT 3000 K, CRI 100

Total lamp luminous flux: 13500 lm, Total luminaire luminous flux: 12012 lm, Total Load: 122.8 W, Luminous efficacy: 97.8 lm/W