SHEARWALL DESIGN

Given:
fc' = 28 MPa 1/12Acv*sqrt(fc') = 529.15026 kN PROVIDE STD HOOK
fy = 414 MPa Min pn = pv = 0.0025
Wall dimension: As min = 1000 mm2/m
hw = 25000 mm
lw = 3000 mm
tw = 400 mm 1/6Acv*sqrt(fc') = 1058.3005 kN PROVIDE 2 CURTAINS OF REINFORCEMENT
Design Forces: DL LL E
P(kN) 200 150 500 CHECK COMPRESSIVE STRESS OF WALL
M(kNm) 3600 Ag = 1200000 mm2
V(kN) 1750 Ig = 9E+11 mm4
Factored Loads: Fc max = 7.35 MPa BOUNDARY ELEMENT IS REQUIRED
Pu = 535 kN
896.5 kN TRIAL SIZE OF BOUNDARY ELEMENT
748 kN b= 350 mm
-352 kN h= 400 mm
Pu = 896.5 kN Governs! d= 2.65 mm
Mu = 0 kN SIZE IS OK
3960 kN BOUNDARY REINFORCEMENTS:
3960 kN Cu = 1942.5896 kN
-3960 kN db = 16 mm
Mu = 3960 kN Governs! n= 8 pcs
Vu = 0 kN As = 1608.50 mm2
1925 kN Ag = 140000 mm2
1925 kN 0pn = 2217.40 kN OK
-1925 kN USE 8 - 16 mm dia
Vu = 1925 kN Governs!
TRANSVERSE REINFORCEMENT:
db = 12 mm
Ab = 113 mm2
Assumed s = 100 mm
hc = 264
Ach = 86400 mm2
Ash1 = 332 mm2 GOVERNS
Ash2 = 161 mm2
Legs = 3
USE 3 legs of 12 mm dia

DESIGN THE WALL FOR SHEAR:


Acv = 1200000 mm2
ac = 2
hw/lw = 8.33
0Vn = 1380 kN NO GOOD

trial db = 16 mm
trial s = 200 mm
pn = 0.0010053

pv = 0.0025
Asv = 1000 mm2
CURTAINS OF REINFORCEMENT

ELEMENT IS REQUIRED