Sei sulla pagina 1di 28

NEW Digital Fiberoptic Sensor

FS-N Series

I n a d d i t i o n to i t s M EG A p owe r,

t h e FS - N S e r i e s i n t r o d u c e s u n p r e c e d e n te d s e t u p e a s e

with one click operation.

NEO-MEGA

ONE CLICK
DATUM
PRESET
Certainty and simplicity
There are two major qualities that are important in fiber sensors.

First, the sensor must have improved basic performance, including ample beam power and accuracy,

for greater detection stability.

Second, the sensor must be easy for anyone to setup and operate.

Instant alarm readout!

2
NEO-MEGA

ONE CLICK
DATUM
PRESET

New Concept

Complete setting in just one click


O N E C L I C K PR E S E T
An entirely new concept in setup ease. Just one click calibrates the sensitivity
and resets the display.

New Concept

Automatic maintenance
DAT U M
The sensor automatically detects reduced light intensity due to debris build-up
and automatically re-calibrates to the original display state.

Simple, Convenient

High power reduces labor hours


NEO-MEGA
Increased sensor power greatly reduces maintenance and setup time.

NEO is supported by the world's highest level


of performance
World’s most powerful World’s highest
World’s most accurate
beam ambient-light resistance

Achieves 250 times


Detects wire as small as Unaffected up to
more light intensity ø0.6 µm (0.024 mil) 30,000 lux

3
New Concept

Complete setting in just one click


Click the button once to simultaneously set the sensitivity
and reset the display value to 100.

What customers are saying

“ I usually just set the sensitivity.

It would be nice if I could reset all of the

settings and current values,

but I wouldn't use this feature


if it's complicated.

CLICK!

PRESET button

All values

“ With the NEO, just one click

sets the sensitivity and


reset to
100
resets the display!

4
ONE CLICK
DATUM NEO-MEGA
PRESET Automatic Harnessing
maintenance power
Carefree
setup

Point 1 Easy to detect changes (preventive maintenance)


The NEO provides an easy-to-read indication when the light intensity drops due to dirt or
other environment related causes.
Conventional problem FS-NEO
Light intensity reduction is difficult to grasp due to individual All sensors initially display 100,
differences in numeric values. making it easy to detect changes.

? Easy to tell
the value
has
Failure! Failure! changed

Point 2 The digital value resets to exactly 100

Conventional problem FS-NEO


The value easily shifted and the initial value The numbers reset to exactly 100.
of 2000 was arbitrary. The set values are reset to 50.

Never reaches Set value Display value


exactly 2000 reset to reset to exactly
50 100

Set ting the value to an easier to read value of 1000 required Resetting numeric values with one click
a complicated operation. T h e a b i l i t y to c h a n g e th e t a rg et offers unprecedented operating ease.
va l u e m a d e i t d i f f i c u l t to ke e p tr a c k of th e o r i g i n a l va l u e.

CLICK!

Point 3 Greater convenience when using


multiple sensors If the light intensity drops
PRESET
button

Correction
required

Pressing PRESET
resets to the
initial state.
The preset function is even
more useful when using
multiple sensors. Quickly
and easily locate sensors
that have become dirty
or misaligned. Main and If the light intensity drops significantly it will not
expansion unit sensors can return to 100.0, making it easy to detect the problem.
be reset with one click by The 2-output type can be used to provide a low light
Light intensity pressing PRESET on the intensity signal to a PLC or similar controller.
drop main unit.

Digital Fiber Sensor FS-N Series > Feature 1 5


ONE CLICK DATUM NEO-MEGA
PRESET
Harnessing
Carefree Automatic power
setup maintenance

New Concept

Automatic maintenance
The automatic maintenance function detects light intensity reduction due to dirt or misalignment,
and returns the sensor to its original display state. This feature can cancel the effects of the
ambient environment, enabling the sensor to continue to perform highly accurate detections.

Automatically recovers by
canceling the effects of
the ambient environment.
Drop due to
dirt build-up

Auto Maintenance!

Original display
state

Light intensity drop due to


an ambient environment

Problem-free environment

DATUM: ON
Automatic maintenance function: DATUM DATUM: ON

Light Intensity
The setting value changes according to the
Light Intensity
intensity as shown in the figure to the right.
Light Intensity
This function corrects the setting value 100.0 DATUM: ON
based on a running average of the received
light intensity value. The correction cycle is Light Intensity
Threshold
the same as the sampling cycle and can be 50.0
selected from three levels.
Light Intensity
Threshold

6 Digital Fiber Sensor FS-N Series > Feature 2


ONE CLICK NEO-MEGA
DATUM
PRESET
Automatic
Carefree maintenance Harnessing
setup power

Simple, Convenient

World’s highest power reduces


maintenance time
"High power" = "large excess gain" that not only reduces the need for maintenance
but also expands sensor head capabilities, which reduces setup time.

1
Switch selectable MEGA power
Power selector
switch Hassle-free operation allows easy changeover
between standard and high power.
SLIDE!
Long distance [MEGA]

3
Prevent light saturation with
a simple operation
Short distance [FINE] Strong light may result in reduced contrast. In
this case, simply press the “MODE” + “SET”
buttons to automatically adjust the NEO to the
proper light intensity.
Target present No target

Light
saturation

Target present No target


Detecting the seam
between transparent
fi lms

2 Reduced light intensity variations


With conventional models, amplifying the projected
beam of condensed light causes the focus of the
Circular
reflector

beam to be sensitive to minute positioning errors LED chip that equally emits Custom LED emits concentrated
in the light-emitting device. The NEO-LED solves light from its entire surface intensity only from the top surface.
Conventional LED NEO-LED
this positioning problem by using a reflector around
The circular reflector helps compensate for light
the light emitting source. The reflector reduces light
positioning errors by redirecting any stray light back into
intensity variations. the fiber.

World's most powerful beam: NEO-MEGA


Guideline for received light intensity 250 times greater than NEO-MEGA, the world's most powerful beam, allows
conventional models for signifi cant improvement of repeatability and hysteresis.
Repeatability (Typical) Hysteresis characteristics (Typical)

FS-N Series FS-N Series


Repeatability

NEO-MEGA Conventional Model* 2 Conventional Model* 2


Hysteresis

Conventional
standard*1

0 50 100 150 mm 0 50 100 150 mm


The emitted light intensity is about 4 times stronger than conventional 1.97" 3.94" 5.91" inch 1.97" 3.94" 5.91" inch
models. Distance Distance
*1. FS-V30 Series in FINE mode *2. FS-V30 Series

Digital Fiber Sensor FS-N Series > Feature 3 7


Convenient functionality designed
for ease of use in the field

Using the external calibration input* Wire saving when adding sensors

PLC

The sensor can be calibrated from a PLC or other external


device. Regularly executing the Preset function from an
When adding sensors, the power is supplied from the
external input ensures uninterrupted, stable detection, even
connector on the side. This reduces wiring by two cables
in harsh environments. The 2-output type can be used to
per sensor, allowing for a neater, quicker installation.
provide a low light intensity signal if the sensor becomes
Note: Only supports FS-N Series amplifiers.
extremely dirty.
* Available on models with external input support. Reliable even when using
multiple sensors
All models equipped with a standard
Easy sensitivity setting heat sink. The heat sink reduces the
temperature of the amplifier, and
(two-point tuning) reduces the stress on the LED light
source as well as other internal parts.

CLICK! Zero Shift


CLICK!
Setting the current value to "0" just got easier. Simply press
the PRESET and RIGHT button at the same time.

CLICK!
CLICK!

Set by simply pressing the SET button once with the target
present, and once without it. Using a NEO amplifier with an
external input, the Zero Shift
adjustment can be performed on a
regular basis using a PLC or other
external device.
No target

Network support COMING SOON

KEYENCE engineers are currently developing a


communication unit that will connect the FS-NEO
directly to an open field network. This will provide
easy read and write access for various settings.

8 Digital Fiber Sensor FS-N Series > Other Features


Complete lineup

Cable Type Model Control


Type External input Analog output
NPN output PNP output outputs

Main unit Main unit FS-N11N FS-N11P


Standard 1 0
Expansion unit FS-N12N FS-N12P
0
Main unit FS-N13N FS-N13P
2-output 2 1
Expansion unit FS-N14N FS-N14P
Expansion
unit Analog Main unit FS-N11MN — 1 0 1

Connector Type Model Control


Type External input Analog output
(M8) NPN output PNP output outputs
Main unit
Main unit FS-N11CN FS-N11CP
Standard 1 1
Expansion unit FS-N12CN FS-N12CP
0
Main unit — FS-N13CP
Expansion 2-output 2 0
unit Expansion unit — FS-N14CP

Optional (sold separately)

Description Model
Amplifier securing bracket
(for main unit)

Can be installed without a DIN-rail. OP-73880


OP-73880
Can be installed from above or from the side.

End unit
(when using expansion units)
Used to secure the main and expansion units. OP-26751
(Two per set) OP-26751
(Two per set)

M8 connector cable
(2 m (6.56')/10 m (32.81')) 2 m (6.56') type
OP-73864
Used to connect to the M8 connector type amplifier (model
numbers end with a “CN” or “CP”). Connector cables are
not included with the amplifier. 10 m (32.81')
type
OP-73865

Digital Fiber Sensor FS-N Series > Lineup 9


Fiber Unit FU Series

Fiber Unit [ F U S e r i es ]
Choose from our selection of more than 100 types of fiber units.

S t a n d a r d Ty p e S t a n d a r d Ty p e
Integrated Bracket Flat
The sensor is integrated into an This thin profile sensor comes with
L-shaped bracket, which simplifies mounting holes for installation
installation. where space is limited.

P.13 P.13

S t a n d a r d Ty p e S t a n d a r d Ty p e
Threaded and Set screw
Cylinder
Hex-shaped Fibers Small size is suitable for installation
Threaded for easy mounting onto in locations where space is limited.
brackets and machine equipment. Installed by drilling a hole and using
a set screw.

P.14 P.16

S t a n d a r d Ty p e F o c u s e d B e a m Ty p e
Sleeve Small Spot Reflective
The fiber tip is a thin sleeve. Ideal for detecting small objects.
Eliminate problems caused by Spot size and focal distance are
limited mounting space. Lineup adjustable, so there is no need to
includes side-view and bendable change the distance between the
sleeve types. sensor and the target.

P.17 P.18

H i g h - p o w e r B e a m Ty p e H i g h - p o w e r B e a m Ty p e
Area Retro-reflective
This sensor forms a wide-area The use of a reflector in place of
beam, making it ideal for moving- the receiver used with thrubeam
target applications, such as sensors simplifies installation and
detection of falling objects. optical axis alignment. This sensor
is suitable for detecting transparent
objects.
P.19 P.19

10
H i g h - p o w e r B e a m Ty p e F i x e d R a n g e Ty p e
Narrow Beam/High-power Definite-reflective
Narrow field of view based on Detects within a fi xed distance.
focused aperture angle. This sensor Reduces the effect of background,
reduces stray light for stable target and features a space-saving thin-
detection. The high-power reflective profile design.
type with an 8° aperture angle is
suitable for detecting objects at
P.20 longer distances. P.20

High-flex O i l /C h e m i c a l R e s i s t a n t
High-flex* Oil/Chemical Resistant
The R2 (R0.08") ToughFlex The PTFE coating allows these
fiber achieves excellent flexing fibers to be used in almost any
characteristics with the same bend environment, including oil- or
radius. chemical-splash conditions.
* 10 million bends

P.21 P.21

Heat Resistant A p p l i c a t i o n - s p e c i f i c Ty p e
Heat Resistant Liquid-level
Ideal for use in high temperature Detects liquid levels when
applications. Withstands immersed or attached to a
temperatures up to 350°C (662°F). transparent tube.

P.22 P.23

A p p l i c a t i o n - s p e c i f i c Ty p e
Liquid Cr ystal/
Semiconductors
Perfect for glass substrate
detection. Lineup offers distance
alignment, edge detection, and
wafer mapping types.

P.23

Digital Fiber Sensor FS-N Series > Fiber Unit > Line-up 11
Model search

Model Page Model Page Model Page

FU- 10 P.18 FU- 48U FU- 77TZ


P.21
FU- 11 FU- 49U FU- 77V P.14
FU- 12 FU- 49X P.16, 21 FU- 78
P.19
FU- 13 FU- 5F FU- 79
P.16 P.21
FU- 15 FU- 5FZ FU- 79U

FU- 16 FU- 50 P.20 FU- 81C

FU- 16Z P.20 FU- 51TZ FU- 82C

FU- 18 FU- 52TZ FU- 83C


P.13
FU- 18M P.20, 23 FU- 53TZ FU- 84C

FU- 20 P.18 FU- 54TZ FU- 85A

FU- 21X P.15 FU- 55 P.16 FU- 85H

FU- 22X P.16, 17 FU- 56 P.16, 17 FU- 85Z


P.22
FU- 23X P.16 FU- 57TE P.21 FU- 86A

FU- 24X FU- 57TZ P.13 FU- 86H


P.15
FU- 25 FU- 58 P.16 FU- 86Z

FU- 31 FU- 58U P.21 FU- 87

FU- 32 FU- 59 P.16, 21 FU- 87K


P.17
FU- 33 FU- 59U P.21 FU- 88

FU- 34 FU- 6F FU- 88K

FU- 35FA FU- 61 P.15 FU- 91


P.21
FU- 35FG FU- 61Z FU- 92

FU- 35FZ P.15 FU- 63 FU- 93

FU- 35TG FU- 63T FU- 93Z


P.17
FU- 35TZ FU- 63Z FU- 95

FU- 37 FU- 65X FU- 95HA P.23


P.20
FU- 38 FU- 66 FU- 95S

FU- 38H FU- 66TZ FU- 95W


P.22, 23
FU- 38K FU- 66Z FU- 95Z

FU- 38L P.23 FU- 67 FU- 96 P.21


P.15
FU- 38LK P.22, 23 FU- 67G FU- A05

FU- 38R FU- 67TG FU- A05D


P.23
FU- 38S FU- 67TZ FU- A10
P.19
FU- 38V P.20, 23 FU- 67V FU- A10D

FU- 4F FU- 68 FU- E11


P.16
FU- 4FZ FU- 69U P.21 FU- E40

FU- 40 FU- 69X FU- L50Z


P.20
FU- 40G FU- 7F P.14 FU- L51Z

FU- 40S P.23 FU- 70U P.21 FU- L52Z


P.13
FU- 41TZ FU- 71 FU- L53Z
P.13 P.14
FU- 42TZ FU- 71Z FU- L54Z

FU- 43 P.17 FU- 73 FU- L41Z

FU- 44TZ P.13 FU- 75F P.17


FU- 45X FU- 76F
P.16, 17
FU- 46 FU- 77

FU- 47TZ P.13 FU- 77G P.14


FU- 48 P.16, 21 FU- 77TG

12 Digital Fiber Sensor FS-N Series > Fiber Unit > Index
Fibre Unit FU Series

Inte grate d B rac ket Integrated bracket and sensor simplifi es installation.

Thrubeam/reflective types
Type Fiber unit length Detecting distance (mm inch)*1 Optical axis diameter
Minimum
(Diameter) Appearance (mm inch) Model
Detecting Beam emitting Optical axis bend radius MEGA Other
Ambient (mm inch) (Standard target to be Weight
method direction height (mm inch) temperature (mm inch) FINE power modes detected)
2 m 6.56' Free-cut (ø2.2 ø0.09")
-40 to + 50˚C
-40 to + 122˚F 0.48" 12.2 FU-L51Z
10 0.39"
12.2
Approx. 30 g
17 0.67"
0.48"
2−ø3.4 ø0.13"
2 m 6.56' Free-cut (ø2.2 ø0.09")
-40 to + 50˚C 0.67" ULTRA: 1700 66.93"
-40 to + 122˚F 17 MEGA: 2200 86.61" SUPER: 1000 39.37" FU-L52Z
Top 15 0.59" ø1.13 ø0.04"
FINE: 450 17.72" TURBO: 760 29.92" Approx. 30 g
12.2 17 0.67"
0.48" HSP: 290 11.42"
2−ø3.4 ø0.13"
2 m 6.56' Free-cut (ø2.2 ø0.09")
-40 to + 50˚C
-40 to + 122˚F 22 R2 R0.08" FU-L53Z
Thrubeam 20 0.79" 0.87"
ToughFlex Approx. 30 g
12.2 17 0.67"
0.48"
2−ø3.4 ø0.13"
2 m 6.56' Free-cut (ø2.2 ø0.09")
-40 to + 50˚C ULTRA: 3600 141.73"
Top -40 to + 122˚F 0.51" 13 MEGA: 3600 141.73" SUPER: 3600 141.73" FU-L50Z
10 0.39" ø3.5 ø0.14"
(lens) FINE: 3100 122.05" TURBO: 3600 141.73" Approx. 30 g
14 20 0.79"
0.55" HSP: 2100 82.68"
2−ø3.4 ø0.13"
2 m 6.56' Free-cut (ø2.2 ø0.09")
-40 to + 50˚C ULTRA: 1500 59.06"
-40 to + 122˚F MEGA: 1900 74.80" SUPER: 900 35.43" FU-L54Z
Side 10 0.39" 2−ø3.4 ø0.13" ø1.13 ø0.04"
FINE: 410 16.14" TURBO: 700 27.56" Approx. 30 g
12.8 0.50"
HSP: 270 10.63"
0.67"17 12.8 0.50"
2 m 6.56' Free-cut (ø2.2 ø0.09")
-40 to + 50˚C ULTRA: 580 22.83"
-40 to + 122˚F R2 R0.08" MEGA: 760 29.92" SUPER: 430 16.93" FU-L41Z
Reflective Top 10 0.39" 0.51" 13 2−ø3.4 −
ø0.13" ToughFlex FINE: 170 6.69" TURBO: 320 12.60" Approx. 25 g
0.55" 14 17 0.67" HSP: 90 3.54"

*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.

Mount directly in locations


Flat where space is limited.

Thrubeam/reflective types
Type Fiber unit length Detecting distance (mm inch)*1 Optical axis diameter
Minimum
(Diameter) Appearance (mm inch) Model
Detecting Beam emitting bend radius MEGA Other
Ambient (mm inch) (Standard target to be Weight
method direction (mm inch) FINE power modes
temperature detected)
1 m 3.28' Free-cut (ø1.0 ø0.04")
-40 to +50˚C 0.39"10 ULTRA: 520 20.47"
-40 to +122˚F MEGA: 810 31.89" SUPER: 340 13.39" FU-51TZ
ø0.5 ø0.02"
2−ø2.1 FINE: 170 6.69" TURBO: 260 10.24" Approx. 5 g
10 0.39"
ø0.08" HSP: 90 3.54"
Thickness: 3 0.12"
Top
2 m 6.56' Free-cut (ø1.3 ø0.05")
0.55"
-40 to +50˚C 14 ULTRA: 1900 74.80"
-40 to +122˚F MEGA: 2900 114.17" SUPER: 1200 47.24" FU-52TZ
ø1 ø0.04"
2−ø3.2
FINE: 610 24.02" TURBO: 850 33.46" Approx. 15 g
ø0.13" 14 0.55" HSP: 260 10.24"
Thickness: 3.5 0.14"
1 m 3.28' Free-cut (ø1.0 ø0.04")
-40 to +50˚C 10.5 0.41" ULTRA: 480 18.90"
-40 to +122˚F ø0.08" R2 R0.08" MEGA: 740 29.13" SUPER: 280 11.02" FU-57TZ
Thrubeam Side 2−ø2.1
ToughFlex FINE: 140 5.51" TURBO: 200 7.87" Approx. 5 g
0.24" 6 HSP: 70 2.76"
Thickness:
2.5 0.10"
ø0.5 ø0.02"
1 m 3.28' Free-cut (ø1.0 ø0.04")
-40 to +50˚C 0.28" 7 ULTRA: 340 13.39"
-40 to +122˚F ø0.08"
0.51" 13 2−ø2.1 MEGA: 500 19.69" SUPER: 230 9.06" FU-53TZ
FINE: 140 5.51" TURBO: 180 7.09" Approx. 10 g
Thickness: HSP: 80 3.15"
2 0.08"
Flat
2 m 6.56' Free-cut (ø2.2 ø0.09")
-40 to +50˚C 0.28" 7 ULTRA: 1900 74.80"
-40 to +122˚F MEGA: 2900 114.17" SUPER: 1200 47.24" FU-54TZ
0.59" 15 2−M3 ø1 ø0.04"
FINE: 610 24.02" TURBO: 850 33.46" Approx. 25 g
Thickness: HSP: 260 10.24"
4 0.16"
1 m 3.28' Free-cut (ø1.0 ø0.04" x 2)
-40 to +50˚C MEGA: 1 to 160 ULTRA: 1 to 120 0.04" to 4.72"
-40 to +122˚F 0.04" to 6.30" SUPER: 1 to 81 0.04" to 3.19" FU-44TZ
Top 2−ø2.1 ø0.08" 6.5 0.26" FINE: 1 to 36 TURBO: 1 to 60 0.04" to 2.36" Approx. 3 g
Thickness: 0.04" to 1.42" HSP: 1 to 13 0.04" to 0.51"
8 0.32" 2 0.08"
1 m 3.28' Free-cut (ø1.0 ø0.04" x 2)
-40 to +50˚C MEGA: 1 to 160 ULTRA: 1 to 120 0.04" to 4.72"
-40 to +122˚F 10.5 0.41" 0.04" to 6.30" SUPER: 1 to 81 0.04" to 3.19" FU-47TZ
Side
2−ø2.1 ø0.08" FINE: 1 to 36 TURBO: 1 to 60 0.04" to 2.36" Approx. 4 g
0.28" 7.2 0.04" to 1.42" HSP: 1 to 18 0.04" to 0.71"
Thickness: 2.5 0.10" R2 R0.08"
Reflective −
1 m 3.28' Free-cut (ø1.0 ø0.04") ToughFlex
-40 to +50˚C MEGA: 2 to 120 ULTRA: 2 to 77 0.08" to 3.03"
-40 to +122˚F 0.08" to 4.72" SUPER: 2 to 50 0.08" to 1.97" FU-41TZ
2−ø2.1 ø0.08" FINE: 2 to 24 TURBO: 2 to 32 0.08" to 1.26" Approx. 5 g
0.51" 13 Thickness: 0.08" to 0.94" HSP: 2 to 8 0.08" to 0.32"
7 0.28" 2 0.08"
Flat
2 m 6.56' Free-cut (ø2.2 ø0.09" x 2)
-40 to +50˚C MEGA: 1 to 500 ULTRA: 1 to 320 0.04" to 12.60"
-40 to +122˚F 0.04" to 19.69" SUPER: 1 to 190 0.04" to 7.48" FU-42TZ
2−ø3.2 ø0.13" FINE: 1 to 70 TURBO: 1 to 130 0.04" to 5.12" Approx. 24 g
0.79" 20 Thickness: 0.04" to 2.76" HSP: 1 to 50 0.04" to 1.97"
7 0.28" 4 0.16"
*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.

Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 13
Most common fi ber sensor.
Threaded and Hex-shaped Fibers Easily mounts onto brackets or machine equipment.

Thrubeam
Type Fiber unit length Detecting distance (mm inch) Optical axis diameter
Minimum
(Diameter) Appearance (mm inch) Model
Detecting bend radius MEGA Other
Size/Shape Ambient (mm inch) (Standard target to be Weight
method temperature (mm inch) FINE power modes detected)
2 m 6.56' Free-cut (ø2.2 ø0.09") ULTRA: 2100 82.68"
-40 to +50˚C 0.57" M4
-40 to +122˚F 14.4 R2 R0.08" MEGA: 3100 122.05" SUPER: 1300 51.18" FU-77TZ
ToughFlex FINE: 640 25.20" TURBO: 880 34.65" Approx. 43 g
HSP: 320 12.60"
Hex-shaped
1 m 3.28' cut not allowed. ULTRA: 1800 70.87"
-40 to +50˚C 0.59" M4
-40 to +122˚F 15 R10 R0.39" MEGA: 1800 70.87" SUPER: 1300 51.18" FU-77TG
Stainless Steel FINE: 640 25.20" TURBO: 880 34.65" Approx. 43 g
HSP: 320 12.60"
2 m 6.56' Free-cut (ø2.2 ø0.09")
-40 to +50˚C
-40 to +122˚F R0.5 R0.02"
ø1.13 ø0.04"
FU-77V
ToughFlex ULTRA: 3000 118.11" Approx. 25 g
M4 MEGA: 3600 141.73" SUPER: 1800 70.87"
14 FINE: 880 34.65" TURBO: 1300 51.18"
0.55" HSP: 430 16.93"
M4
R2 R0.08" FU-77
ToughFlex Approx. 21 g

1 m 3.28' cut not allowed. ULTRA: 1800 70.87"


-40 to +50˚C
Thrubeam Threaded -40 to +122˚F M4 R10 R0.39" MEGA: 1800 70.87" SUPER: 1800 70.87" FU-77G
22 0.87" Stainless Steel FINE: 880 34.65" TURBO: 1300 51.18" Approx. 39 g
HSP: 430 16.93"
2 m 6.56' Free-cut (ø2.2 ø0.09") ULTRA: 3200 125.98"
-40 to +70˚C
-40 to +158˚F M4 R25 R0.98"
MEGA: 3600 141.73" SUPER: 2200 86.61" FU-7F
15 0.59" FINE: 1100 43.31" TURBO: 1500 59.06" Approx. 21 g
HSP: 540 21.26"
ø1 ø0.04"
2 m 6.56' Free-cut (ø1.3 ø0.05") ULTRA: 1400 55.12"
-40 to +70˚C
-40 to +158˚F M4 R4 R0.16"
MEGA: 2200 86.61" SUPER: 860 33.86" FU-78
15 0.59" FINE: 440 17.32" TURBO: 600 23.62" Approx. 9 g
HSP: 220 8.66"
2 m 6.56' Free-cut (ø2.2 ø0.09") ULTRA: 3600 141.73"
FU-71Z: -40 to +50˚C -40 to +122˚F
FU-71: -40 to +70˚C -40 to +158˚F R2 R0.07" MEGA: 3600 141.73" SUPER: 2300 90.55" FU-71Z
ToughFlex FINE: 1100 43.31" TURBO: 1600 62.99" Approx. 25 g
M6
HSP: 590 23.23"
M6 Threaded 16
ø1.5 ø0.06"
ULTRA: 3600 141.73"
0.63"
R25 R0.98"
MEGA: 3600 141.73" SUPER: 2600 90.55" FU-71
FINE: 1300 51.2" TURBO: 1800 70.87" Approx. 25 g
HSP: 650 25.59"

Thrubeam Lenses
Ambient temperature Detecting distance (mm inch)*1
Model Applicable fiber
Type Appearance
Weight units MEGA ULTRA SUPER TURBO FINE HSP
(mm inch)

Heat Resistance: 2700 F-4


70°C 158°F FU-77TZ/77V/77 106.30"
Ultra-long detecting ø0.17"
3600 3200
distance
Tip: ø4.3 FU-7F 141.73" 125.98"
F-4
Narrow field of view
Approx. 1 g 2200
Aperture Angle: FU-78
Approx. 8° 86.61"
9.5 1800
0.37" FU-77G/77TG 70.87"
Heat Resistance: FU-77TZ/77V/77/ 3600 2100 F-2
300°C 572°F 84C/88K 141.73" 82.68
3600 2500
ø0.16" FU-7F/86A 141.73" 98.43"
Long-detecting Tip: ø4
distance F-2 3600 1900
Aperture Angle: Approx. 2 g
FU-86Z 141.73" 74.80"
Approx. 15°
3600 3300 1600
7.9 FU-78 141.73" 129.92" 62.99"
0.31"
1800
FU-77G/77TG 70.87"
Heat Resistance: 2600 F-5
105°C 221°F FU-77V/77 102.36"
Fixing Nut
3100
FU-7F/86A 122.05"
3600
Side-view with F-5 141.73" 2900
mounting holes Approx. 10 g
FU-86Z 114.17"
5.6 2300
9.3 0.22" FU-78 90.55"
0.37" 16.7
0.66"
1800
FU-77G 70.87"
Heat Resistance: 3600 3100 1900 1300 900 530 F-1
70°C 158°F*2 FU-77V/77 141.73" 122.05" 74.80" 51.18" 35.43" 20.87"
1800 1300 900 530
ø0.16" FU-77G 70.87" 51.18" 35.43" 20.87"
Tip: ø4
F-1 3600 3100 2100 1300 630
Side-view
Approx. 2 g
FU-7F/86A 141.73" 122.05" 82.68" 51.18" 24.80"

9.5 3600 3300 2300 1500 1100 500


3.74"
FU-86Z 141.73" 129.92" 90.55" 59.06" 43.31" 19.69"
3200 2500 1600 1100 800 360
FU-78/84C/88K 125.98" 98.43" 62.99" 43.31" 31.50" 14.17"
*1 The maximum sensing distance of 3600 mm 141.73" (1800 mm 70.87") is possible because the fiber length on each side is 2 m 6.56' (1 m 3.28').
*2 When using the F-1 at 70°C 158°F or more, specify the "Heat-resistant F-1".Be sure to use the "Heat-resistant F-1" at a constant temperature.

14
Fibre Unit FU Series

Reflective
Type Fiber unit length Minimum Detecting distance (mm inch)*1
(Diameter) Appearance Model
Detecting Detecting bend radius MEGA Other
Size/Shape Ambient (mm inch) Weight
method arrangement temperature (mm inch) FINE power modes
1 m 3.28' Free-cut 0.73"
(ø1.3 ø0.05 x 2) 18.5 MEGA: 400 15.75" ULTRA: 270 10.63"
-40 to +50˚C FINE: 70 2.76" SUPER: 170 6.69" FU-35TZ
Hex-shaped -40 to +122˚F TURBO: 110 4.33" Approx. 7 g
M3 Lens attachment: P.18 HSP: 32 1.26"
R2 R0.08"
1 m 3.28' Free-cut ToughFlex
(ø1.3 ø0.05 x 2)
-40 to +50˚C 0.67" 17
FU-35FZ
-40 to +122˚F
MEGA: 450 17.72" Approx. 6 g
M3 ULTRA: 290 11.42"
FINE: 72 2.76" SUPER: 190 7.48"
1 m 3.28' Free-cut TURBO: 115 4.53"
(ø1.3 ø0.05 x 2) HSP: 36 1.42"
Spiral 30 cm 0.71" 18
R10 R0.39" FU-35FG
-40 to +50˚C Stainless Steel
-40 to +122˚F
Lens attachment: P.18 Approx. 15 g
M3

M3 Coaxial
1 m 3.28' Free-cut
(ø1.3 ø0.05 x 2) MEGA: 550 21.65" ULTRA: 400 15.75"
-40 to +70˚C 0.91" 23 SUPER: 250 9.84" FU-35FA
Threaded FINE: 110 4.33"
-40 to +158˚F TURBO: 160 6.30"
M3
Approx. 6 g
Lens attachment: P.18 HSP: 45 1.77"
R25 R0.98"
50 cm 1.64' cut not allowed.
FU-21X: -40 to +70˚C -40 to +158˚F MEGA: 130 5.12" ULTRA: 90 3.54"
FU-24X: -40 to +50°C -40 to +122˚F FINE: 36 1.42" SUPER: 54 2.13" FU-21X
TURBO: 40 1.57" Approx. 4 g
Lens attachment: P.18 HSP: 23 0.91"
0.59" 15
MEGA: 100 3.94" ULTRA: 72 2.83"
M3
R10 R0.39" FINE: 13 0.51" SUPER: 32 1.26" FU-24X
TURBO: 23 0.91" Approx. 4 g
Lens attachment: P.18 HSP: 8 0.32"
2 m 6.56' Free-cut
(ø1.3 ø0.05 x 2) 0.53"13.5 ULTRA: 420 16.54"
-40 to +50˚C MEGA: 640 25.2" SUPER: 320 12.60" FU-66TZ
Hex-shaped -40 to +122˚F FINE: 140 5.51" TURBO: 220 8.66" Approx. 10 g
M4 HSP: 70 2.76"
R2 R0.08"
2 m 6.56' Free-cut ToughFlex
(ø1.3 ø0.05 x 2) ULTRA: 560 22.05"
FU-66Z: -40 to +50°C -40 to +122˚F MEGA: 770 30.32" SUPER: 380 14.96" FU-66Z
M4 FU-66: -40 to +70˚C -40 to +158˚F FINE: 190 7.48" TURBO: 260 10.24" Approx. 10 g
HSP: 80 3.15"
Threaded 0.59" 15
ULTRA: 860 33.86"
Parallel R25 R0.98"
MEGA: 1100 43.31" SUPER: 570 22.44" FU-66
M4
FINE: 300 11.81" TURBO: 410 16.14" Approx. 10 g
HSP: 140 5.51"
2 m 6.56' Free-cut
(ø2.2 ø0.09 x 2) 0.62" 15.8
-40 to +50˚C R2 R0.08" FU-67TZ
Reflective -40 to +122˚F ToughFlex Approx. 32 g
ULTRA: 550 21.65"
M6
MEGA: 710 27.95" SUPER: 470 18.50"
1 m 3.28' cut not allowed. FINE: 210 8.27" TURBO: 310 12.20"
-40 to +50˚C 0.67" 17 HSP: 90 3.54"
-40 to +122˚F FU-67TG
Hex-shaped
Approx. 32 g
M6
R10 R0.39"
1 m 3.28' cut not allowed. Stainless Steel
-40 to +50˚C 0.89" 22.5 MEGA: 400 15.75" ULTRA: 270 10.63"
-40 to +122˚F FINE: 70 2.76" SUPER: 170 6.69" FU-35TG
Coaxial
TURBO: 110 4.33" Approx. 32 g
M6 Lens attachment: P.18 HSP: 32 1.26"
2 m 6.56' Free-cut
(ø2.2 ø0.09 x 2)
0.63" 16
ULTRA: 740 29.13"
-40 to +50˚C R0.5 R0.02" MEGA: 900 35.43" SUPER: 490 19.29" FU-67V
-40 to +122˚F ToughFlex FINE: 210 8.27" TURBO: 320 12.60" Approx. 25 g
M6 HSP: 110 4.33"
2 m 6.56' Free-cut
(ø2.2 ø0.09 x 2) 0.67" 17 ULTRA: 900 35.43"
-40 to +50˚C MEGA: 1200 47.24" SUPER: 590 23.23" FU-61Z
-40 to +122˚F FINE: 300 11.81" TURBO: 430 16.93" Approx. 22 g
M6 HSP: 140 5.51"
R2 R0.08"
M6
2 m 6.56' Free-cut ToughFlex
(ø2.2 ø0.09 x 2) 0.63" 16
-40 to +50˚C FU-67
-40 to +122˚F
Approx. 21 g
M6 ULTRA: 740 29.13"
MEGA: 900 35.43" SUPER: 490 19.29"
Parallel
1 m 3.28' cut not allowed. FINE: 210 8.27" TURBO: 320 12.60"
-40 to +50˚C 0.67" 17 HSP: 110 4.33"
-40 to +122˚F R10 R0.39" FU-67G
Threaded
Stainless Steel Approx. 29 g
M6

2 m 6.56' Free-cut
(ø2.2 ø0.09 x 2) 0.67"17 ULTRA: 1000 39.37"
-40 to +70˚C MEGA: 1300 51.18" SUPER: 820 32.28" FU-61
-40 to +158˚F FINE: 380 14.96" TURBO: 500 19.69" Approx. 21 g
M6 HSP: 160 6.30"
2 m 6.56' Free-cut
(ø2.2 ø0.09 x 2) 0.67"17 ULTRA: 860 33.86"
-40 to +70˚C MEGA: 1100 43.31" SUPER: 570 22.44" FU-6F
-40 to +158˚F R25 R0.98"
FINE: 300 11.81" TURBO: 410 16.14" Approx. 21 g
M6 HSP: 140 5.51"
2 m 6.56' Free-cut
(ø2.2 ø0.09 x 2) 0.67"17 ULTRA: 630 24.8"
-40 to +70˚C MEGA: 720 28.35" SUPER: 410 16.14" FU-25
Coaxial -40 to +158˚F FINE: 160 6.30" TURBO: 270 10.63" Approx. 18 g
M6 HSP: 130 5.12"

*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.

Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 15
Small size is suitable for installation in locations where space is limited.
C y linde r Installed by drilling a hole and using a set screw.

Thrubeam/reflective types
Type Fiber unit length Detecting distance (mm inch)*1 Optical axis diameter
Minimum
(Diameter) Appearance (mm inch) Model
Detecting Size bend radius MEGA Other
Ambient (mm inch) (Standard target to be Weight
method (mm inch) temperature (mm inch) FINE power modes detected)
50 cm 1.64' cut not allowed.
-40 to +50˚C ULTRA: 270 10.63"
ø0.04" ø1
-40 to +122˚F
ø1.0 ø0.04" R10 R0.39"
MEGA: 380 14.96" SUPER: 180 7.09"
ø0.265 ø0.01"
FU-58
6
0.24" FINE: 85 3.35" TURBO: 120 4.72" Approx. 8 g
HSP: 40 1.57"

1 m 3.28' Free-cut
(ø1.0 ø0.04) ø0.06" ø1.5 ULTRA: 810 31.89"
-40 to +70˚C
ø1.5 ø0.06" -40 to +158˚F 10
R4 R0.16" MEGA: 1200 47.24" SUPER: 590 23.23"
ø0.7 ø0.03"
FU-59
0.39" High-flex FINE: 230 9.06" TURBO: 410 16.14" Approx. 3 g
HSP: 130 5.12"

50 cm 1.64' cut not allowed.


-40 to +70˚C ø0.10" ø2.5
-40 to +158˚F
FU-55
10 Approx. 3 g
0.39"
ULTRA: 32 1.26"
MEGA: 45 1.77" SUPER: 23 0.91"
Thrubeam ø2.5 ø0.10" R10 R0.39" ø0.125 ø005"
50 cm 1.64' cut not allowed. FINE: 13 0.51" TURBO: 18 0.71"
-40 to +70˚C ø0.10" ø2.5 HSP: − −
-40 to +158˚F ø0.01" ø0.3
10
FU-56
5 0.39" Approx. 3 g
0.20"
Do not bend sleeve
2 m 6.56' Free-cut
(ø2.2 ø0.09) ø0.12" ø3 ULTRA: 3000 118.11"
-40 to +50˚C
-40 to +122˚F R2 R0.08" MEGA: 3600 171.73" SUPER: 1800 70.87"
ø1.13 ø0.04"
FU-5FZ
14 ToughFlex FINE: 880 34.65" TURBO: 1300 51.18" Approx. 19 g
0.55"
HSP: 430 16.93"
ø3 ø0.12"
2 m 6.56' Free-cut ø0.12"
(ø2.2 ø0.09) ø3 ULTRA: 3200 125.98"
-40 to +70˚C
-40 to +158˚F R25 R0.98"
MEGA: 3600 171.73" SUPER: 2200 86.61"
ø1 ø0.04"
FU-5F
15 FINE: 1100 43.30" TURBO: 1500 59.06" Approx. 19 g
0.59"
HSP: 540 21.26"

1 m 3.28' cut not allowed


-40 to +70˚C 0.59" ULTRA: 100 3.94"
-40 to +158˚F 15 R4 R0.16" MEGA: 150 5.91" SUPER: 80 3.15" FU-49X
ø1.5 ø0.06"
High-flex FINE: 32 1.26" TURBO: 54 2.13" Approx. 3 g
HSP: 22 0.87"
ø1.5 ø0.06"
1 m 3.28' cut not allowed
-40 to +70˚C 0.59" ULTRA: 18 0.71"
-40 to +158˚F 0.12" 15
3
R10 R0.39"
MEGA: 27 1.06" SUPER: 13 0.51" FU-46
ø1.5 FINE: 4.8 0.19" TURBO: 10 0.39" Approx. 2 g
ø0.5 ø0.06"
ø0.02" HSP: 2.4 0.09"
Do not bend sleeve
50 cm 1.64' cut not allowed
-40 to +70˚C 0.55"
0.24" 14 ULTRA: 59 2.32"
-40 to +158˚F
ø2.5 ø0.10"
6
R25 R0.98"
MEGA: 72 2.83" SUPER: 45 1.77" FU-22X
ø2.5 FINE: 23 0.91" TURBO: 32 1.26" Approx. 4 g
ø1.77 ø0.10"
ø0.07" HSP: 12 0.47"
Do not bend sleeve
2 m 6.56' Free-cut (ø1.3 ø0.05 x 2)
FU-4FZ: -40 to +50°C -40 to +122˚F ULTRA: 560 22.05"
FU-4F: -40 to +70˚C -40 to +158˚F
R2 R0.08" MEGA: 770 30.32" SUPER: 380 14.96" FU-4FZ
ToughFlex FINE: 190 7.48" TURBO: 260 10.24" Approx. 8 g
0.67" HSP: 80 3.15"
17
Reflective −
ø3 ULTRA: 860 33.86"
ø0.12"
R25 R0.98"
MEGA: 1100 43.30" SUPER: 570 22.44" FU-4F
FINE: 300 11.81" TURBO: 410 16.14" Approx. 8 g
HSP: 140 5.51"

2 m 6.56' Free-cut (ø1.0 ø0.04 x 2)


-40 to +70˚C 0.59" ULTRA: 200 7.87"
-40 to +158˚F 15
ø3 ø0.12"
R4 R0.16" MEGA: 290 11.42" SUPER: 130 5.12" FU-48
High-flex FINE: 63 2.48" TURBO: 80 3.15" Approx. 7 g
ø3 HSP: 32 1.26"
ø0.12"

50 cm 1.64' cut not allowed


-40 to +70˚C 0.67" ULTRA: 680 26.77"
-40 to +158˚F 17
R25 R0.98"
MEGA: 830 32.68" SUPER: 470 18.50" FU-23X
FINE: 180 7.09" TURBO: 320 12.60" Approx. 4 g
ø3 HSP: 130 5.12"
ø0.12"

50 cm 1.64' cut not allowed


-40 to +70˚C 0.59"
ULTRA: 54 2.13"
-40 to +158˚F 0.20" 15
5
R4 R0.16"
MEGA: 68 2.68" SUPER: 40 1.57" FU-45X
ø3 FINE: 18 0.71" TURBO: 27 1.06" Approx. 4 g
ø0.82 ø0.12"
ø0.03" HSP: 8 0.32"
Do not bend sleeve

*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.

16
Fibre Unit FU Series

Sle eve Eliminate problems caused by limited mounting space.

Thrubeam/reflective types
Type Fiber unit length Detecting distance (mm inch)*1 Optical axis diameter
Minimum
(Diameter) Appearance (mm inch) Model
Detecting Beam emitting bend radius MEGA Other
Ambient (mm inch) (Standard target to be Weight
method direction temperature (mm inch) FINE power modes detected)
1 m 3.28' Free-cut (ø1.3 ø0.05")
-40 to +70˚C ø0.10" ø2.5
-40 to +158˚F ULTRA: 380 14.96"
ø0.82 MEGA: 520 20.47" SUPER: 230 9.06" FU-32
ø0.03" ø0.6 ø0.02"
15 FINE: 100 3.94" TURBO: 160 6.30" Approx. 5 g
15 0.59" HSP: 55 2.17"
0.59"
Side- Do not bend sleeve
view 2 m 6.56' Free-cut
(ø2.2 ø0.09") 0.59"
-40 to +70˚C
15 ULTRA: 1100 43.31"
-40 to +158˚F 2.56" ø3 ø0.12" R25 R0.98"
MEGA: 1600 62.99" SUPER: 660 25.98" FU-34
65 FINE: 330 12.99" TURBO: 470 18.50" Approx. 17 g
ø1.2 ø0.05" R0.98" HSP: 140 5.51"
Min. bend radius of sleeve: R25
M4 ø1 ø0.04"
2 m 6.56' Free-cut ø0.07"
(ø2.2 ø0.09") ø1.65
-40 to +70˚C ULTRA: 3200 125.98"
15 0.59" MEGA: 3600 141.73" SUPER: 2200 86.61" FU-73
-40 to +158˚F
67
2.64" FINE: 1100 43.31" TURBO: 1500 59.06" Approx. 24 g
Min. bend radius
HSP: 540 21.26"
of sleeve: R10 R0.39"
Thrubeam
1 m 3.28' Free-cut
(ø1.0 ø0.04") ø0.03" M3
-40 to +70˚C ø0.82 ULTRA: 500 19.69"
-40 to +158˚F 15 MEGA: 690 27.17" SUPER: 340 13.39"
ø0.5 ø0.02"
FU-75F
15 0.59" FINE: 170 6.69" TURBO: 240 9.45" Approx. 10 g
0.59" HSP: 72 2.83"
Top Do not bend sleeve
view 1 m 3.28' Free- Free-cut
(ø1.0 ø0.04") ø0.02" ø3
ULTRA: 260 10.24"
-40 to +70˚C ø0.4 15 0.59"
-40 to +158˚F R10 R0.39"
MEGA: 370 14.57" SUPER: 180 7.09"
ø0.265 ø0.01"
FU-76F
1.77"
45 FINE: 85 3.35" TURBO: 120 4.72" Approx. 10 g
HSP: 40 1.57"
Min. bend radius of sleeve: R10 R0.39"
50 cm 1.64' cut not allowed ø0.10"
-40 to +70˚C ø2.5
ø0.01" ULTRA: 32 1.26"
-40 to +158˚F ø0.3
10 MEGA: 45 1.77" SUPER: 23 0.91"
ø0.125 ø0.004"
FU-56
5 0.39" FINE: 13 0.51" TURBO: 18 0.71" Approx. 3 g
0.20" HSP: − −
Do not bend sleeve
2 m 6.56' Free-cut
(ø1.0 ø0.04" x 2) ø0.11"
-40 to +70˚C ø0.08"
ø2.8 ULTRA: 130 5.12"
-40 to +158˚F ø2 R10 R0.39"
MEGA: 180 7.09" SUPER: 81 3.19" FU-31
15 0.59" FINE: 32 1.26" TURBO: 50 1.97" Approx. 5 g
15 0.59" HSP: 18 0.71"
Do not bend sleeve
Side ø0.19"
1 m 3.28' Free-cut
(ø2.2 ø0.09" x 2) ø4.8
-40 to +70˚C ULTRA: 250 9.84"
ø0.08"
-40 to +158˚F ø2.1 15
R25 R0.98"
MEGA: 320 12.60" SUPER: 140 5.51" FU-33
0.59" FINE: 45 1.77" TURBO: 90 3.54" Approx. 10 g
Min. bend
65 radius of HSP: 32 1.26"
2.56" sleeve: R25 R0.98"
50 cm 1.64' cut not allowed
-40 to +70˚C
-40 to +158˚F ø0.03" M3 ULTRA: 54 2.13"
ø0.82 R4 R0.16"
MEGA: 68 2.68" SUPER: 40 1.57" FU-65X
15 0.59" FINE: 18 0.71" TURBO: 27 1.06" Approx. 5 g
15 0.59" HSP: 8 0.32"
Do not bend sleeve
2 m 6.56' Free-cut
(ø1.3 ø0.05" x 2) M4
-40 to +50˚C ø0.08" ULTRA: 190 7.48"
-40 to +122˚F ø2 15 R2 R0.08" MEGA: 290 11.42" SUPER: 120 4.72" FU-63Z
0.59" ToughFlex FINE: 54 2.13" TURBO: 80 3.15" Approx. 10 g
67 2.64"
Min. bend radius of HSP: 23 0.91"
sleeve: R10 R0.39"
2 m 6.56' Free-cut
(ø1.3 ø0.05" x 2) M4
-40 to +70˚C ø0.07"
-40 to +158˚F ø1.65 15 FU-63
0.59" Approx. 10 g
67 2.64"
Min. bend radius of ULTRA: 230 9.06"
sleeve: R10 R0.39" MEGA: 330 12.99" SUPER: 150 5.91"
Reflective R25 R0.98" −
2 m 6.56' Free-cut FINE: 72 2.83" TURBO: 100 3.94"
(ø1.3 ø0.05 x 2) HSP: 36 1.42"
-40 to +70˚C ø0.07"
Top -40 to +158˚F ø1.65 15
FU-63T
0.59" Approx. 10 g
67 2.64"
Min. bend radius of
sleeve: R10 R0.39"
50 cm 1.64' cut not allowed
-40 to +70˚C ø0.12"
-40 to +158˚F ø0.03" ø3 ULTRA: 54 2.13"
ø0.82 R4 R0.16"
MEGA: 68 2.68" SUPER: 40 1.57" FU-45X
15 0.59" FINE: 18 0.71" TURBO: 27 1.06" Approx. 4 g
5 0.20" HSP: 8 0.32"
Do not bend sleeve
2 m 6.56' Free-cut
(ø1.3 ø0.05" x 2) ø4
-40 to +70˚C ø0.07" ULTRA: 230 9.06"
-40 to +158˚F ø1.65
R25 R0.98"
MEGA: 330 12.99" SUPER: 150 5.91" FU-43
15 0.59"
FINE: 72 2.83" TURBO: 100 3.94" Approx. 8 g
22 0.87" HSP: 36 1.42"
Do not bend sleeve
1 m 3.28' cut not allowed
-40 to +70˚C ø0.06"
-40 to +158˚F ø0.02" ø1.5 ULTRA: 18 0.71"
R10 R0.39"
MEGA: 27 1.06" SUPER: 13 0.51" FU-46
ø0.5
15 0.59" FINE: 4.8 0.19" TURBO: 10 0.39" Approx. 2 g
3 0.12" HSP: 2.4 0.09"
Do not bend sleeve
50 cm 1.64' cut not allowed
-40 to +70˚C ø0.10"
-40 to +158˚F ø0.07" ø2.5 ULTRA: 59 2.32"
Coaxial, narrow
beam ø1.77
R25 R0.98"
MEGA: 72 2.83" SUPER: 45 1.77" FU-22X
14 0.55" FINE: 23 0.91" TURBO: 32 1.26" Approx. 4 g
10° 6 0.24" HSP: 12 0.47"
Do not bend sleeve

*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.

Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 17
Ideal for detecting small objects.
Small Spot Ref le cti ve Select the sensor according to the size of the object.

Parallel Beam Spot


Lens + Fiber Unit
Beam spot Lens Fiber units Detecting distance (mm inch)*1 F-3HA
Type diameter Appearance (mm inch) Minimum MEGA Other
(mm inch) Model bend radius Appearance Model
Weight (mm inch) FINE power modes
R2 R0.08"
ToughFlex FU-35FZ MEGA: 45 ULTRA: 45 1.77"
1.77" SUPER: 45 1.77"
R10 R0.39" FINE: 36 TURBO: 40 1.57"
Approx. Stainless FU-35FG 1.42" HSP: 27 1.06"
Steel
ø4 ø0.16" ø0.17"
Tip: ø4.3 R25 R0.98" MEGA: 65 ULTRA: 65 2.56"
(within the
Parallel 2.56" SUPER: 65 2.56"
beam
detecting F-3HA FU-35FA FINE: 54 TURBO: 60 2.36"
distance of
9.5 2.13" HSP: 45 1.77"
0 to 20 mm
0.37" R2 R0.08"
0" to 0.79")
Approx. 2 g ToughFlex FU-35TZ MEGA: 40 ULTRA: 40 1.57"
1.57" SUPER: 40 1.57"
R10 R0.39" FINE: 27 TURBO: 32 1.26"
Stainless Steel FU-35TG 1.06" HSP: 23 0.91"
*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.

Small Beam Spot


Lens + Fiber Unit
Beam spot Lens Fiber units F-2HA
Focal distance
Type diameter Appearance (mm inch) Minimum bend
(mm inch) Model Appearance Model
(mm inch) Weight radius (mm inch)
Approx. R10 R0.39"
ø0.1 ø0.004"
FU-24X

Approx. R25 R0.98"


ø0.2 ø0.008"
FU-21X
R2 R0.08"
ToughFlex FU-35FZ
ø0.17"
Tip: ø4.3 R10 R0.39"
7±2
0.28"±0.08"
F-2HA Stainless Steel FU-35FG
15.6 0.61"
Approx. R25 R0.98"
ø0.4 ø0.02" Approx. 1 g FU-35FA
R2 R0.08"
ToughFlex FU-35TZ
R10 R0.39"
Stainless Steel FU-35TG
R2 R0.08"
ToughFlex FU-35FZ F-4HA

R10 R0.39"
Small spot Stainless Steel FU-35FG
ø0.29"
Tip: ø7.4 R2 R0.08"
Approx. 15±2
ø0.5 ø0.02" 0.59"±0.08"
F-4HA ToughFlex FU-35TZ
27 1.06"
R10 R0.39"
Approx. 2 g
Stainless Steel FU-35TG
R25 R0.98"
FU-35FA

Approx. R25 R0.98"


FU-21X F-6HA
ø1.0 ø0.04"
R2 R0.08"
ø0.42" ToughFlex FU-35FZ
Tip: ø10.6
35±3 R10 R0.39"
1.38"±0.12"
F-6HA Stainless Steel FU-35FG
Approx. 26
ø2.0 ø0.08" 1.02" R2 R0.08"
Approx. 5 g ToughFlex FU-35TZ
R25 R0.98"
FU-35FA

Built-in Lens Fiber Unit


Beam spot diameter Focal distance Fiber unit length (Diameter) Appearance Model Minimum bend
Type
(mm inch) (mm inch) Ambient temperature (mm inch) Weight radius (mm inch)
50 cm 1.64' cut Tip: ø3 ø0.12"
Approx. 5 not allowed FU-20
Small spot -40 to +70˚C R25 R0.98"
ø0.1 ø0.004" 0.20" -40 to +158˚F Approx. 2 g
18 0.71"

Adjustable Beam Spot


Built-in Lens Fiber Unit
Beam spot diameter Focal distance Fiber unit length (Diameter) Appearance Model Minimum bend
Type (mm inch) (mm inch) Ambient temperature (mm inch) Weight radius (mm inch)
2 m 6.56' Free-cut M6
Adjustable ø0.9 to 3.5 10 to 30 (ø1.3 ø0.05 x 2) FU-10
-40 to +70˚C R25 R0.98"
beam spot ø0.04" to 0.14" 0.39" to 1.18" -40 to +158˚F Approx. 5 g
26.4 1.04" to 31.5 1.24"

Lens + Fiber Unit


Beam spot Lens Fiber units F-5HA
Focal distance
Type diameter Appearance (mm inch) Minimum bend
(mm inch) Model Appearance Model
(mm inch) Weight radius (mm inch)
8.7 0.34" R2 R0.08"
ToughFlex FU-35FZ
5.6
Side-view R10 R0.39"
ø0.5 to 3 8 to 30 0.22"
adjustable
ø0.02" to 0.12" 0.32" to 1.18"
F-5HA Stainless Steel FU-35FG
spot Approx. 15
2g 0.59" R25 R0.98"
FU-35FA

18
Fibre Unit FU Series

Great for applications where target position varies or


A re a for detecting targets with complicated shapes or rough surface fi nish.

Thrubeam/reflective types
Type Fiber unit length Minimum Detecting distance (mm inch)*1 Optical axis
(Diameter) Appearance Model
Detecting Optical axis bend radius MEGA Other diameter
Type Ambient (mm inch) Weight
method width (mm inch) temperature (mm inch) FINE power modes (mm inch)
0.79" 20
ULTRA: 2800 110.24"
10 0.39"
2 m 6.56' Free-cut
20 MEGA: 3400 133.86" SUPER: 2400 94.49" 10×3 FU-12
(ø2.2 ø0.09") 0.79" FINE: 1400 55.12" TURBO: 1700 66.93" 0.39"×0.12" Approx. 23 g
-40 to +50˚C
-40 to +122˚F HSP: 640 25.20"
1.17" 29.8
0.41"10.5 ULTRA: 3600 141.73"
Area 11 0.43"
2 m 6.56' Free-cut R2 R0.08" MEGA: 3600 141.73" SUPER: 3600 141.73" 11×2 FU-E11
(ø2.2 ø0.09") ToughFlex FINE: 2700 106.30" TURBO: 3600 141.73" 0.43"×0.08" Approx. 20 g
-40 to +50˚C
-40 to +122˚F Thickness: 4.0 0.16" HSP: 1300 51.18"
2.72" 69
0.77" 19.5 ULTRA: 3600 141.73"
Thrubeam 40 1.57"
2 m 6.56' Free-cut MEGA: 3600 141.73" SUPER: 3600 141.73" 40×3 FU-E40
(ø2.2 ø0.09") FINE: 3600 141.73" TURBO: 3600 141.73" 1.57"×0.12" Approx. 30 g
-40 to +50˚C
-40 to +122˚F Thickness: 5.1 0.20" HSP: 2500 98.43"
0.59" 15
Thickness: Approx.
5 0.20"
2 m 6.56' Free-cut 4.0 0.16"
6 x 0.3
FU-A05
(ø2.2 ø0.09") 0.59" 15 Approx. 20 g
-40 to +70˚C ULTRA: 1400 55.12" 0.24"×0.01"
-40 to +158˚F MEGA: 2200 86.61" SUPER: 840 33.07"
Array 0.79" 20
R4 R0.16"
Thickness: FINE: 440 17.32" TURBO: 540 21.25"
4.0 HSP: 200 7.87" Approx.
10 0.39"
2 m 6.56' Free-cut
20 0.16" 11 x 0.3
FU-A10
(ø2.2 ø0.09") 0.79" Approx. 20 g
-40 to +70˚C 0.43"×0.01"
-40 to +158˚F
2 m 6.56' Free-cut (ø2.2 ø0.09" x 2)
MEGA: 5 to 200 ULTRA: 5 to 200 0.20" to 7.87"
15 0.59" -40 to +70˚C
Area (at distance 15 -40 to +158˚F 15 0.59" R25 R0.98"
0.20" to 7.87" SUPER: 5 to 200 0.20" to 7.87"

FU-11
7 0.28" FINE: 5 to 140 TURBO: 5 to 160 0.20" to 6.30" Approx. 19 g
0.59")
28 1.10" 0.20" to 5.51" HSP: 5 to 110 0.20" to 4.33"
0.79" 20 20
10 0.39" 0.79"
Refl ective (at distance 4
2 m 6.56' Free-cut

FU-A05D
(ø2.2 ø0.09" x 2) Approx. 20 g
0.16") -40 to +70˚C ULTRA: 460 18.11"
-40 to +158˚F Thickness: 4.0 0.16" MEGA: 740 29.13" SUPER: 260 10.24"
Array R4 R0.16"
0.79" 20 20 FINE: 140 5.51" TURBO: 180 7.09"
15 0.59" 0.79" HSP: 60 2.36"
(at distance 4
2 m 6.56' Free-cut

FU-A10D
(ø2.2 ø0.09" x 2) Approx. 20 g
0.16") -40 to +70˚C
-40 to +158˚F Thickness: 4.0 0.16"

*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.

Retro-ref le cti ve Useful for detecting transparent objects.

Retro-reflective type
Type Minimum Detecting distance (mm inch)*1
Fiber unit length Appearance Model
Detecting Beam emitting (Diameter) bend radius MEGA Other
method direction Ambient temperature (mm inch) (mm inch) FINE power modes
Weight

2 m 6.56' Free-cut (ø1.0 ø0.04" x 2)


-40 to +50˚C
-40 to +122˚F MEGA: 10 to 960 ULTRA: 10 to 760 0.39" to 29.92"
M6
R2 R0.08" 0.39" to 37.80" SUPER: 10 to 380 0.39" to 14.96" FU-13
0.67" 17 ToughFlex FINE: 10 to 120 TURBO: 10 to 230 0.39" to 9.06" Approx. 8 g
Reflective tape 0.39" to 4.72" HSP: − −
M6 (accessory)
Retro-
Reflective 2 m 6.56' Free-cut
(ø1.0 ø0.04" x 2)
-40 to +50˚C 0.79" MEGA: 100 to 6400 ULTRA: 100 to 5000 4.72" to 196.85"
-40 to +122˚F 20.8 4.72" to 251.97" SUPER: 100 to 2500 4.72" to 98.43" FU-15
Square type 26.9 R10 R0.39"
FINE: 100 to 1260 TURBO: 100 to 1690 4.72" to 66.54" Approx. 12 g
1.06"
4.72" to 49.61" HSP: 100 to 1000 4.72" to 39.37"
Reflector
Thickness: 12.6 0.50" R-2 (accessory)
*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.

Reflector/Reflective Tape Specifications (Optional Parts)


Detecting distance (mm inch)*1
R-2 (OP-95388) R-3 (OP-96436) R-5 Reflective tape (OP-96629)

Model Power modes


51.2 x 61 35 x 42 14 x 36 40 x 30
(2.02" x 2.40") (1.38" x 1.65") (0.55" x 1.42") (1.57" x 1.18")

MEGA 10 to 1880 0.39" to 74.02" 10 to 1540 0.39" to 60.63" 10 to 1060 0.39" to 41.73" 10 to 960 0.39" to 37.80"
ULTRA 10 to 1500 0.39" to 59.06" 10 to 1240 0.39" to 48.82" 10 to 860 0.39" to 33.86" 10 to 760 0.39" to 29.92"
SUPER 10 to 760 0.39" to 29.92" 10 to 640 0.39" to 25.20" 10 to 440 0.39" to 17.32" 10 to 380 0.39" to 14.96"
FU-13
TURBO 10 to 450 0.39" to 17.72" 10 to 360 0.39" to 14.17" 10 to 230 0.39" to 9.06" 10 to 230 0.39" to 9.06"
FINE 10 to 250 0.39" to 9.84" 10 to 200 0.39" to 7.87" 10 to 130 0.39" to 5.12" 10 to 120 0.39" to 4.72"
HSP − − − −
MEGA 100 to 6400 3.94" to 251.97" 100 to 4400 3.94" to 173.23" 100 to 2600 3.94" to 102.36"
ULTRA 100 to 5000 3.94" to 196.85" 100 to 3600 3.94" to 141.73" 100 to 2200 3.94" to 86.61"
SUPER 100 to 2500 3.94" to 98.43" 100 to 2000 3.94" to 78.74" 100 to 1500 3.94" to 59.06"
FU-15* 2 −
TURBO 100 to 1690 3.94" to 66.54" 100 to 1350 3.94" to 53.15" 100 to 1200 3.94" to 47.24"
FINE 100 to 1260 3.94" to 47.61" 100 to 1000 3.94" to 39.37" 100 to 1000 3.94" to 39.37"
HSP 100 to 1000 3.94" to 39.37" 100 to 860 3.94" to 33.86" 100 to 860 3.94" to 33.86"
*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.
*2 Reflective tape cannot be used.

Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 19
Built-in lens reduces beam width
Narrow Beam/High-power and helps reduce stray light.

Thrubeam/reflective types
Type Fiber unit length Detecting distance (mm inch)*1 Optical axis diameter
Minimum
(Diameter) Appearance (mm inch) Model
Detecting Beam emitting bend radius MEGA
Aperture angle Ambient (mm inch)
(mm inch) Other power modes (Standard target to be Weight
method direction temperature FINE detected)
2 m 6.56' Free-cut (ø1.0 ø0.04")
FU-16Z: -40 to +50˚C -40 to +122˚F
ULTRA: 3600 141.73"
FU-16/18: -40 to +70˚C -40 to +158˚F R2 R0.08" MEGA: 3600 141.73" SUPER: 2600 102.36" FU-16Z
ToughFlex FINE: 1260 49.61" TURBO: 1800 70.87" Approx. 8 g
HSP: 760 29.92"
Approx. 6°
ø0.16" ULTRA: 3600 141.73"
ø4 MEGA: 3600 141.73" SUPER: 3600 141.73" FU-16
ø2.5 ø0.10"
FINE: 1900 74.80" TURBO: 2700 106.30" Approx. 8 g
HSP: 1000 39.37"
Side 13
0.51" ULTRA: 3600 141.73"
17
Thrubeam Approx. 2° 0.67" R10 R0.39"
MEGA: 3600 141.73" SUPER: 3000 118.11" FU-18
FINE: 1600 62.99" TURBO: 2100 92.68" Approx. 8 g
HSP: 960 37.80"
2 m 6.56' Free-cut (ø1.0 ø0.04")
-40 to +70˚C
ULTRA: 900 35.43"
Approx. 3° -40 to +158˚F MEGA: 1300 51.18" SUPER: 680 26.77"
ø1 ø0.04"
FU-18M
1.5 FINE: 330 12.99" TURBO: 530 20.87" Approx. 6 g
0.06" 2
0.08" 20 0.79" HSP: 210 8.27"
2 m 6.56' Free-cut (ø1.0 ø0.04")
-40 to +50˚C 0.16"
ULTRA: 3600 141.73"
Top Approx. 6° -40 to +122˚F 4 R2 R0.08" MEGA: 3600 141.73" SUPER: 3600 141.73"
ø2.8 ø0.11"
FU-50
12 0.47" ToughFlex FINE: 3600 141.73" TURBO: 3600 141.73" Approx. 8 g
3.6 0.14" HSP: 2400 94.49"
2 m 6.56' Free-cut (ø2.2 ø0.09" x 2)
-40 to +50˚C ULTRA: 30 to 1600
-40 to +122˚F R2 R0.08" 1.18" to 62.99" FU-40
Thickness: 5.2 ToughFlex MEGA: 30 to 2300 SUPER: 30 to 760 Approx. 23 g
0.20" 21 0.83" 1.18" to 90.55" 1.18" to 29.92"
Reflective Top Approx. 8° −
1 m 3.28' cut not allowed FINE: 30 to 290 TURBO: 30 to 410
-40 to +50˚C R10 R0.39" 1.18" to 11.42" 1.18" to 16.14"
-40 to +122˚F Stainless
FU-40G
HSP: 30 to 160 Approx. 50 g
Thickness: 5.2 Steel 1.18" to 6.30"
0.20" 21 0.83"

*1 3600 mm 141.73" is assumed as maximum because the fiber cable has a length of 2 m 6.56'.
Detecting distance for reflective fibers is based on a standard target: White matte paper.

Helps reduce the effect of target background.


D ef in i te -ref l e c ti ve The thin, small design requires less space.

Definite-reflective types
Type Fiber unit length Detecting distance (mm inch)*1
Minimum Beam spot
(Diameter) Appearance Model
Detecting Beam emitting Ambient bend radius MEGA Other diameter
(mm inch) Weight
method direction (mm inch) FINE power modes (mm inch)
temperature
2 m 6.56' Free-cut Approx. ø4.5 ø0.18
(ø1.0 ø0.04" x 2) 14.4 0.57" MEGA: 3 (0.12") center of ULTRA: 3 (0.12") center of detecting distance Approx.
-40 to +70˚C detecting distance SUPER: 3 (0.12") center of detecting distance ø3.5 FU-37
Side -40 to +158˚F ø0.14
FINE: 3 (0.12") center of TURBO: 3 (0.12") center of detecting distance Approx. 6 g
Thickness: (at distance of
19 detecting distance HSP: 3 (0.12") center of detecting distance
0.75" 5 0.20"
3 0.12")
2 m 6.56' Free-cut 12 0.47"
(ø1.0 ø0.04" x 2) MEGA: 6 (0.24") center of ULTRA: 6 (0.24") center of detecting distance Approx.
Definite- -40 to +70˚C detecting distance SUPER: 6 (0.24") center of detecting distance ø1.5 ø0.06" FU-38
-40 to +158˚F R10 R0.39"
reflective FINE: 6 (0.24") center of TURBO: 6 (0.24") center of detecting distance (at distance of Approx. 5 g
19 Thickness: detecting distance HSP: 6 (0.24") center of detecting distance 6 0.24")
0.75" 4 0.16"
Top
2 m 6.56' Free-cut 12 0.47"
(ø1.0 ø0.04" x 2) ULTRA: 0 to 4 0" to 0.16"
-40 to +70˚C MEGA: 0 to 4 0" to 0.16" SUPER: 0 to 4 0" to 0.16" FU-38V
-40 to +158˚F −
Thickness:
FINE: 0 to 4 0" to 0.16" TURBO: 0 to 4 0" to 0.16" Approx. 5 g
19 4.3 0.17" HSP: 2±1.4 0.08"±0.06"
0.75"

*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.

20
Fibre Unit FU Series

Provides higher fl exibility than electric wire.


High-f lex R2 (R0.08") types are resistant to repeated bends up to 10 million bends.

Thrubeam/reflective types
Type Fiber unit length Detecting distance (mm inch)*1 Optical axis diameter
Minimum
(Diameter) Appearance (mm inch) Model
Detecting Size bend radius MEGA Other
Ambient (mm inch) (Standard target to be Weight
method (mm inch) (mm inch) FINE power modes
temperature detected)
1 m 3.28' Free-cut ø0.06" ø1.5
(ø1.0 ø0.04" ) FU-59
ø1.5 ø0.06" -40 to +70˚C 10
-40 to +158˚F ULTRA: 810 31.89" Approx. 3 g
0.39"
MEGA: 1200 47.24" SUPER: 590 23.23"
1 m 3.28' Free-cut (ø1.0 ø0.04" ) FINE: 230 9.06" TURBO: 410 16.14"
-40 to +70˚C R4 R0.16" HSP: 130 5.12" FU-79
M3 -40 to +158˚F ø0.7 ø0.03"
10 High-flex Approx. 6 g
M3 0.39"
1 m 3.28' Free-cut ULTRA: 490 19.29"
6×10.5×2.5 (ø1.0 ø0.04" ) MEGA: 630 24.80" SUPER: 290 11.42" FU-57TE
0.24"×0.41"×0.10" -40 to +70˚C
-40 to +158˚F FINE: 110 4.33" TURBO: 180 7.09" Approx. 5 g
0.24" 6 10.5 0.41" HSP: 65 2.56"
1 m 3.28' Free-cut ø0.04" ø1
(ø1.0 ø0.04" ) FU-58U
Thrubeam ø1.0 ø0.04" -40 to +50˚C 6
-40 to +122˚F 0.24"
Approx. 4 g

1 m 3.28' Free-cut ø0.06" ø1.5 ULTRA: 430 16.93"


(ø1.0 ø0.04" ) MEGA: 590 23.23" SUPER: 300 11.81" FU-59U
ø1.5 ø0.06" -40 to +50˚C ø0.5 ø0.02"
-40 to +122˚F
10 FINE: 140 5.51" TURBO: 180 7.09" Approx. 4 g
0.39" R2 R0.08"
HSP: 55 2.17"
ToughFlex
1 m 3.28' Free-cut M3
(ø1.0 ø0.04" ) High-flex
M3
FU-79U
-40 to +50˚C
-40 to +122˚F 10 Approx. 4 g
0.39"
1 m 3.28' Free-cut M4 ULTRA: 1800 70.87"
M4 (ø1.0 ø0.04" ) MEGA: 1800 70.87" SUPER: 1800 70.87" FU-70U
-40 to +50˚C ø2.3 ø0.09"
Built-in lens -40 to +122˚F 13 FINE: 850 33.46" TURBO: 1200 47.24" Approx. 5 g
0.51" HSP: 370 14.57"
1 m 3.28' cut not allowed
-40 to +70˚C ø0.06" ø1.5 FU-49X
ø1.5 ø0.06" -40 to +158˚F
15 0.59"
ULTRA: 100 3.94" Approx. 3 g
MEGA: 150 5.91" SUPER: 80 3.15"
1 m 3.28' cut not allowed M3 FINE: 32 1.26" TURBO: 54 2.13"
-40 to +70˚C HSP: 22 0.87" FU-69X
M3 -40 to +158˚F
Approx. 3 g
10 0.39"
R4 R0.16"
2 m 6.56' Free-cut High-flex
(ø1.0 ø0.04" x 2) ø0.12" ø3 FU-48
ø3 ø0.12" -40 to +70˚C
-40 to +158˚F ULTRA: 200 7.87" Approx. 7 g
15 0.59" MEGA: 290 11.42" SUPER: 130 5.12"
2 m 6.56' Free-cut FINE: 63 2.48" TURBO: 80 3.15"
(ø1.0 ø0.04" x 2) M4
Reflective M4
HSP: 32 1.26"

FU-68
-40 to +70˚C
-40 to +158˚F Approx. 8 g
15 0.59"
1 m 3.28' Free-cut
(ø1.0 ø0.04" x 2) ø0.08" ø2 FU-49U
ø2 ø0.08" -40 to +50˚C
-40 to +122˚F Approx. 4 g
10 0.39"
1 m 3.28' Free-cut ULTRA: 110 4.33"
(ø1.0 ø0.04" x 2) ø0.12" ø3 R2 R0.08"
ø3 ø0.12" ToughFlex
MEGA: 140 5.51" SUPER: 80 5.12" FU-48U
-40 to +50˚C
-40 to +122˚F FINE: 40 1.57" TURBO: 60 2.36" Approx. 4 g
10 0.39" High-flex
HSP: 13 0.51"
1 m 3.28' Free-cut
(ø1.0 ø0.04" x 2) M3
M3
FU-69U
-40 to +50˚C
-40 to +122˚F Approx. 4 g
13 0.51"

*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.

Oil/Chemical Resistant PTFE coating allows for use in almost any environment.

Thrubeam/Reflective types
Type Fiber unit length Detecting distance (mm inch)*1 Optical axis diameter
Minimum
(Diameter) Appearance (mm inch) Model
Detecting Beam emitting Size bend radius MEGA Other
Ambient (mm inch) (Standard target to be Weight
method direction (mm inch) (mm inch) FINE power modes
temperature detected)
2 m 6.56' Free-cut (ø2.2 ø0.09")
-40 to +70˚C
ULTRA: 3600 141.73"
Top ø5 ø0.20" -40 to +158˚F R40 R1.57"
MEGA: 3600 141.73" SUPER: 3600 141.73"
ø3.7 ø0.15"
FU-92
22 0.87" FINE: 2800 110.24" TURBO: 3600 141.73" Approx. 71 g
ø5 ø0.87" HSP: 1400 55.12"
Thrubeam
2 m 6.56' Free-cut
(ø2.2 ø0.09")
ULTRA: 3600 141.73"
Side ø5 ø0.20" -40 to +70˚C R40 R1.57"
MEGA: 3600 141.73" SUPER: 3000 118.11"
ø2.8 ø0.11"
FU-96
-40 to +158˚F FINE: 1100 43.31" TURBO: 2200 86.61" Approx. 71 g
ø0.20" ø5 23 1.44" HSP: 510 20.08"
2 m 6.56' Free-cut (ø1.3 ø0.05" x 2)
-40 to +70˚C
ULTRA: 290 11.42"
Reflective Top ø4.5 ø0.18" -40 to +158˚F ø0.18" R40 R1.57"
MEGA: 310 12.20" SUPER: 250 9.84"

FU-91
ø4.5 FINE: 140 5.51" TURBO: 200 7.87" Approx. 32 g
22 0.87" HSP: 80 3.15"

*1 3600 mm 141.73" is assumed as maximum because the fiber cable has a length of 2 m 6.56'. Detecting distance for reflective fibers is based on a standard target: White matte paper.

Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 21
Resists temperatures up to 350°C (662°F).
He at Re sista nt A wide variety of heat-resistant types are available, including the easy-to-install R5(R0.20") type and the high-temperature type, resistant to temperatures up to
350°C (662°F). Fibers used in sensors resistant to temperatures of 200°C (392°F) or more are made from multi-component glass.

Thrubeam/reflective types
Type Fiber unit length Detecting distance (mm inch)*1 Optical axis diameter
Minimum
(Diameter) Appearance (mm inch) Model
Detecting Heat resistant Ambient bend radius MEGA Other
(mm inch) (Standard target to be Weight
method 2
temperatures* temperature (mm inch) FINE power modes detected)
2 m 6.56' Free-cut (ø2.2 ø0.09" )
-40 to +100˚C MEGA: 3600 141.73" ULTRA: 2200 86.61"
100˚C 212˚F*3 -40 to +212˚F
R5 R0.20" FINE: 680 26.77" SUPER: 1600 62.99" FU-86Z
15 ToughFlex TURBO: 900 35.43" Approx. 25 g
0.59"
M4 Lens attachment: P14 HSP: 390 15.35"
ø1 ø0.04"
2 m 6.56' Free-cut (ø2.2 ø0.09" )
-40 to +105˚C MEGA: 3600 141.73" ULTRA: 3200 125.98"
105˚C 221˚F* 3 -40 to +221˚F R25 R0.98" FINE: 1100 43.31" SUPER: 2200 86.61" FU-86A
15 TURBO: 1500 59.06" Approx. 22 g
M4 0.59" Lens attachment: P14 HSP: 540 21.26"
2 m 6.56' Free-cut (ø2.2 ø0.09" )
-40 to +150˚C
ULTRA: 1800 70.87"
150˚C 302˚F*4 -40 to +302˚F R20 R0.79"
MEGA: 2700 106.30" SUPER: 1100 43.31" FU-86H
17 0.67" FINE: 520 20.47" TURBO: 720 28.35" Approx. 35 g
M4 HSP: 340 13.39"
Thrubeam ø1.5 ø0.06"
2 m 6.56' Free-cut (ø2.2 ø0.09" )
-60 to +180˚C
ULTRA: 1900 74.80"
180˚C 356˚F* 5 -76 to +356˚F R35 R1.38"
MEGA: 2700 106.30" SUPER: 1200 47.24" FU-88
17 0.67" FINE: 570 22.44" TURBO: 790 31.10" Approx. 36 g
M4 HSP: 380 14.96"
2 m 6.56' cut not allowed.
-40 to +200˚C
200˚C 392˚F -40 to +392˚F 10 0.39" R8 R0.32"
FU-88K
15 MEGA: 1800 70.87" Approx. 30 g
0.59" ULTRA: 1300 51.18"
M4 FINE: 390 15.35" SUPER: 900 35.43"
ø1 ø0.04"
2 m 6.56' cut not allowed. TURBO: 680 26.77"
-40 to +300˚C HSP: 250 9.84"
300˚C 572˚F -40 to +572˚F 10 0.39" R25 R0.98"
FU-84C
15 Lens attachment: P14 Approx. 66 g
M4 0.59"

2 m 6.56' Free-cut (ø2.2 ø0.09" x 2)


-40 to +100˚C
ULTRA: 580 22.83"
100˚C 212˚F*3 -40 to +212˚F M6 R5 R0.20" MEGA: 740 29.13" SUPER: 410 16.14" FU-85Z
ToughFlex FINE: 160 6.30" TURBO: 320 12.60" Approx. 25 g
17 0.67" HSP: 90 3.54"
2 m 6.56' Free-cut (ø2.2 ø0.09" x 2)
-40 to +105˚C
ULTRA: 860 33.86"
105˚C 221˚F*3 -40 to +221˚F M6 R25 R0.98"
MEGA: 1100 43.31" SUPER: 590 23.23" FU-85A
FINE: 230 9.06" TURBO: 410 16.14" Approx. 21 g
17 0.67" HSP: 140 5.51"
2 m 6.56' Free-cut (ø2.2 ø0.09" x 2)
-40 to +150˚C
ULTRA: 560 22.05"
150˚C 302˚F*4 -40 to +302˚F R20 R0.79"
MEGA: 720 28.35" SUPER: 410 16.14" FU-85H
M6
FINE: 160 6.30" TURBO: 320 12.60" Approx. 35 g
17 0.67" HSP: 90 3.54"
2 m 6.56' Free-cut (ø2.2 ø0.09" x 2)
-60 to +180˚C
ULTRA: 710 27.95"
180˚C 356˚F*5 -76 to +356˚F R35 R1.38"
MEGA: 860 33.86" SUPER: 470 18.50" FU-87
M6 FINE: 200 7.87" TURBO: 350 13.78" Approx. 33 g
17 0.67" HSP: 100 3.94"
1 m 3.28' cut not allowed.
-40 to +200˚C
200˚C 392˚F -40 to +392˚F R8 R0.32"
FU-87K
M4 Approx. 15 g
10 0.39"
17 0.67"
1 m 3.28' cut not allowed. M4 ULTRA: 650 25.59"
-40 to +300˚C 35 1.38"
Reflective -40 to +572˚F MEGA: 770 30.32" SUPER: 450 17.72"

FU-82C
ø0.08" ø2.1 FINE: 190 7.48" TURBO: 340 13.38" Approx. 29 g
90 Min. bend radius of
3.54" sleeve R10 R0.39" HSP: 100 3.94"
300˚C 572˚F
1 m 3.28' cut not allowed.
-40 to +300˚C M4
-40 to +572˚F ø0.10"
R25 R0.98"
FU-83C
ø2.6 Approx. 23 g
10 0.39"
17 0.67"
1 m 3.28' cut not allowed. M4
-30 to +350˚C
ULTRA: 560 22.05"
-22 to +572˚F 40 1.57" MEGA: 650 25.59" SUPER: 390 15.35" FU-81C
350˚C 662˚F
ø0.08" ø2.1 FINE: 140 5.51" TURBO: 290 11.42" Approx. 24 g
90 Min. bend radius of
3.54" sleeve R10 R0.39" HSP: 86 3.39"
2 m 6.56' cut not allowed.
-40 to +250˚C
MEGA: 8 to 37 ULTRA: 8 to 34 0.32" to 1.34"
0.67" Thickness: 5
-40 to +482˚F 0.20"
0.32" to 1.46" SUPER: 8 to 32 0.32" to 1.26" FU-38LK
17.1
FINE: 8 to 30 TURBO: 8 to 30 0.32" to 1.18" Approx. 70 g
29.7 1.17" 0.32" to 1.18" HSP: 10 to 18 0.39" to 0.71"
250˚C 482˚F R25 R0.98"
1 m 3.28' cut not allowed.
-40 to +250˚C
0.75" Thickness: 5 ULTRA: 2.5 to 55
-40 to +482˚F 0.20" 0.10" to 2.17" FU-38K
19
MEGA: 2.5 to 65 SUPER: 2.5 to 27 Approx. 45 g
27 1.06"
0.10" to 2.56" 0.10" to 1.06"
2 m 6.56' Free-cut FINE: 2.5 to 16 TURBO: 2.5 to 22
(ø2.2 ø0.09" x 2) Thickness: 5 0.10" to 0.63" 0.10" to 0.87"
180˚C 356˚F -60 to +180˚C 0.75"
0.20" R35 R1.38"
FU-38H
-76 to +356˚F
19 HSP: 2.5 to 10 Approx. 45 g
27 1.06" 0.10" to 0.39"

*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.(For the FU-38LK, the distances are based on a glass substrate (t = 0.7 mm 0.03") detected in the
planar direction.)
*2 Use the fiber sensor under dry conditions. Allow some margin for the temperature upper limit when selecting a heat-resistant fiber unit.
*3 The recommended maximum ambient temperature during operation is 90°C 194°F when constantly using a fiber unit in a high-temperature environment.
*4 The recommended maximum ambient temperature during operation is 130°C 266°F when constantly using a fiber unit in a high-temperature environment.
*5 The recommended maximum ambient temperature during operation is 150°C 302°F when constantly using a fiber unit in a high-temperature environment.

22
Fibre Unit FU Series

Liquid-level detection sensors.


L iquid-leve l Available in tube-mountable and immersible types.

Reflective
Type Fiber unit length Minimum
Appearance Model
Transparent tube (Diameter) bend radius Accessory
Detecting method Beam axis (mm inch) Weight
diameter (mm inch) Ambient temperature (mm inch)
2 m 6.56' Free-cut
(ø2.2 ø0.09" x 2)
16 -40 to +70˚C R5 R0.20"
Binding band x 2 FU-95S
-40 to +158˚F Nonslip rubber x 2 Approx. 23 g

2 m 6.56' Free-cut (ø1.0 ø0.04" x 2)


FU-95Z: -40 to +50°C -40 to +122˚F
FU-95HA: -40 to +105°C -40 to +221˚F R2 R0.08" FU-95Z
FU-95: -40 to +70˚C -40 to +158˚F ToughFlex Approx. 7 g
ø4 to 26
ø0.16" to 1.02" Binding band x 2
Nonslip rubber x 2
Tube-mountable
1 R25 R0.98" Spacer x 2
FU-95HA
type Approx. 7 g
Screw x 2
Nut x 2

R10 R0.39"
FU-95
Approx. 7 g

2 m 6.56' Free-cut
(ø2.2 ø0.09" x 2)
ø26 ø1.02" or more
16 -40 to +70˚C R5 R0.20"
None FU-95W
recommended -40 to +158˚F (Optionally available) Approx. 20 g

Type Fiber unit length (Diameter) Appearance Minimum bend radius (mm inch) Model
Detecting method Ambient temperature (mm inch) PFA-sheathed section Fiber Weight
2 m 6.56' Free-cut (ø1.3 ø0.05" x 2)
FU-93Z: -40 to +50°C -40 to +158˚F R0.5 R0.02" FU-93Z
FU-93 : -40 to +70°C -40 to +158˚F ToughFlex Approx. 78 g
Immersion R40 R1.57" *

ø6 (PFA) R25 R0.98"


FU-93
Approx. 78 g * Not bendable up to 80 mm
ø0.24" (3.15") from the tip.

Perfect for detecting glass substrates.


Liquid Crystal/Semiconductors Lineup offers distance alignment, edge detection, and wafer mapping types.

Thrubeam
Type Fiber unit length Detecting distance (mm inch)*1 Optical axis diameter
Minimum
(Diameter) Appearance (mm inch) Model
Beam emitting bend radius MEGA Other
Application Aperture angle Ambient (mm inch)
(mm)
(Standard target to be Weight
direction temperature FINE power modes detected)
2 m 6.56' Free-cut (ø1.0 ø0.04")
-40 to +70˚C
ULTRA: 900 35.43"
Mapping Side Approx. 3° -40 to +158˚F R10 R0.39"
MEGA: 1300 51.18" SUPER: 680 26.77"
ø1 ø0.04"
FU-18M
1.5 FINE: 330 12.99" TURBO: 530 20.87" Approx. 6 g
0.06"
0.08" 2 20 0.79" HSP: 210 8.27"

Reflective
Type Fiber unit length Detecting distance (mm inch)*1
Minimum
(Diameter) Appearance Model
Beam emitting Heat resistant*2 bend radius MEGA Other
Application Ambient (mm inch) Weight
direction temperatures (mm inch) FINE power modes
temperature
2 m 6.56' Free-cut
(ø2.2 ø0.09" x 2)
MEGA: 15 to 70 ULTRA: 15 to 60 0.59" to 2.36"
Glass substrate
Top -40 to +70˚C 7.4 0.29" 0.59" to 2.76" SUPER: 15 to 46 0.59" to 1.81" FU-40S
mapping -40 to +158˚F FINE: 15 to 30 TURBO: 15 to 38 0.59" to 1.50" Approx. 25 g
0.75" 19 17 0.67" 0.59" to 1.18" HSP: − −
R25 R0.98"
2 m 6.56' Free-cut 14 0.55"
(ø2.2 ø0.09" x 2)
MEGA: 8 to 38 ULTRA: 8 to 36 0.32" to 1.42"
-10 to +60˚C 0.32" to 1.50" SUPER: 8 to 35 0.32" to 1.38" FU-38L
14 to +140˚F FINE: 8 to 32 TURBO: 8 to 34 0.32" to 1.34" Approx. 20 g
20 Thickness:
0.79" 5.2 0.20" 0.32" to 1.26" HSP: 10 to 26 0.39" to 1.02"
2 m 6.56' Free-cut
(ø2.2 ø0.09" x 2)
20.5 0.81" MEGA: 0 to 25 ULTRA: 0 to 25 0" to 0.98"
Glass substrate
− -40 to +70˚C R5 R0.20"
0" to 0.98" SUPER: 0 to 25 0" to 0.98" FU-38S
alignment -40 to +158˚F FINE: 0 to 25 TURBO: 0 to 25 0" to 0.98" Approx. 20 g
29 Thickness:
1.14" 3.6 0.14" 0" to 0.98" HSP: − −
Flat
2 m 6.56' Free-cut
(ø2.2 ø0.09" x 2)
22 0.87" MEGA: 0 to 14 ULTRA: 0 to 14 0" to 0.55"
-40 to +70˚C R25 R0.98"
0" to 0.55" SUPER: 0 to 14 0" to 0.55" FU-38R
-40 to +158˚F FINE: 0 to 14 TURBO: 0 to 14 0" to 0.55" Approx. 20 g
29 Thickness:
1.14" 3.8 0.15" 0" to 0.55" HSP: 0 to 12 0" to 0.47"
2 m 6.56' Free-cut 12 0.47"
(ø1.0 ø0.04" x 2)
MEGA: 0 to 4 ULTRA: 0 to 4 0" to 0.16"
Seating check -40 to +70˚C R10 R0.39"
0" to 0.16" SUPER: 0 to 4 0" to 0.16" FU-38V
-40 to +158˚F FINE: 0 to 4 TURBO: 0 to 4 0" to 0.16" Approx. 5 g
19 Thickness:
0.75" 4.3 0.17" 0" to 0.16" HSP: 2±1.4 0.08"±0.06"
2 m 6.56' cut not allowed.
MEGA: 8 to 37 ULTRA: 8 to 34 0.32" to 1.34"
Heat-resistant -40 to +250˚C
glass substrate -40 to +482˚F 0.32" to 1.46" SUPER: 8 to 32 0.32" to 1.26" FU-38LK
0.67" 17.1 FINE: 8 to 30 TURBO: 8 to 30 0.32" to 1.18" Approx. 70 g
alignment 29.7 Thickness:
1.17" 5 0.20" 0.32" to 1.46" HSP: 10 to 18 0.39" to 0.71"
250˚C 482˚F R25 R0.98"
1 m 3.28' cut not allowed.
-40 to +250˚C
Flat -40 to +482˚F FU-38K
0.75" 19 Thickness: MEGA: 2.5 to 65 ULTRA: 2.5 to 55 0.10" to 2.17" Approx. 45 g
Heat-resistant 27
1.06" 5 0.20" 0.10" to 2.56" SUPER: 2.5 to 27 0.10" to 1.06"
seating, presence
2 m 6.56' Free-cut FINE: 2.5 to 16 TURBO: 2.5 to 22 0.10" to 0.87"
check (ø2.2 ø0.09" x 2) 0.10" to 0.63" HSP: 2.5 to 10 0.10" to 0.39" FU-38H
180˚C 356˚F*3 -40 to +180˚C 0.75" R35 R1.38"
19
-40 to +356˚F
27 Thickness:
Approx. 45 g
1.06" 5 0.20"

*1 Detecting distance for reflective fibers is based on a standard target: White matte paper.(For the FU-38LK, the distances are based on a glass substrate (t = 0.7 mm 0.03") detected in the
planar direction.)
*2 Use the fiber sensor under dry conditions. Allow some margin for the temperature upper limit when selecting a heat-resistant fiber unit.
*3 The recommended maximum ambient temperature during operation is 150°C 302°F when constantly using a fiber unit in a high-temperature environment.

Digital Fiber Sensor FS-N Series > Fiber Unit > Selection Chart 23
Spe cif ic ations

Monitor
Standard 1 output High functionality 2 output
Type output

Cable M8 connector*1 Cable M8 connector*1 Cable


NPN FS-N11N FS-N12N FS-N11CN FS-N12CN FS-N13N FS-N14N – – FS-N11MN
Model
PNP FS-N11P FS-N12P FS-N11CP FS-N12CP FS-N13P FS-N14P FS-N13CP FS-N14CP –

Expansion Expansion Expansion Expansion


Main unit/Expansion unit Main unit Main unit Main unit Main unit Main unit
unit unit unit unit

Control output 1 1 1 1 2 2 2 2 1
Monitor output (1-5 V) – – – – – – – – 1
External input – – 1 1 1 1 – – –
Response time 50 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA)

NPN open collector 30 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/
NPN output
20 mA or less (multiple connections); residual voltage 1 V or less
Control
output
PNP open collector 30 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/
PNP output
20 mA or less (multiple connections); residual voltage 1 V or less

Monitor output*2 1 to 5 V voltage output; load resistance 10 kΩ or more; repeat precision ±0.5% of F.S.; 1 ms response time (HIGH SPEED, FINE, TURBO)*3
External input input time 2 ms (ON)/20 ms (OFF) or more

Multiple connections to Expansion


Up to 16 units can be connected total (two output type is treated as two units)
units

Light source Red, 4-element LED


APC ON/OFF switchable (Factory setting: OFF)

Number of interference prevention 0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA
units (When set to double, the number of interference-prevention units will be doubled.)

Power voltage 12 - 24 V DC ±10% ripple (P-P) 10% or less

NPN Amplifier Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*4


Current Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*4
Consumption Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)

Rating Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. Normal: 1050 mW or less (42 mA max. at 24 V, 56 mA
at 12 V)*4 max. at 12 V)*4
PNP Amplifier
Eco on mode: 850 mW or less (35 mA max. at 24 V, 44 mA Eco on mode: 950 mW or less (38 mA max. at 24 V, 47 mA
Current –
max. at 12 V)*4 max. at 12 V)*4
Consumption
Eco Full mode: 520 mW or less (21 mA max. at 24 V, 26 Eco Full mode: 600 mW or less (24 mA max. at 24 V, 29
mA max. at 12 V) mA max. at 12 V)

Operating
ambient Incandescent lamp: 20000 lux or less; Sunlight: 30000 lux or less
luminance
Operating
ambient -20 to +55 °C -4 to +131 °F (no freezing)*5
temperature
Environmental
resistance Operating
35 to 85% RH (no condensation)
ambient humidity

Vibration
10 to 55 Hz Compound amplitude 1.5 mm 0.06", 2 hours for each of X,Y,Z axis
resistance

Shock resistance 500 m/s2 3 times for each of X,Y,Z axis

Case material Both main unit and expansion unit housing material: Polycarbonate

Weight Approx. 75 g Approx. 45 g Approx. 22 g Approx. 22 g Approx. 80 g Approx. 70 g Approx. 22 g Approx. 22 g Approx. 75 g

*1 Use a cable length of 30m (98.43') or less for M8 connector types.


*2 FS-N11MN only
*3 SUPER: 1.2 ms, ULTRA: 1.8 ms, MEGA: 4.2 ms
*4 Increases 100 mW (4.0 mA) for High Speed mode
*5 One or two more units connected: -20 to +55°C (-4 to +131°F); 3 to 10 more units connected: -20 to +50°C (-4 to +122°F); 11 to 16 more units connected: -20 to +45°C (-4 to +113°F). When
using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.

24 Digital Fiber Sensor FS-N Series > Specifications


Input and Output Circuit Diagra ms

FS-N11N / N12N / N11MN / N13N / N14N


Output Circuit Diagram Input Circuit Diagram (FS-N13N/N14N only)
*1 FS-N11N/N11MN/N13N only
3.3VDC
12-24VDC *2 FS-N11MN only
Brown*1

Sensor main circuit


Sensor main circuit

Protection

Monitor output (1-5 V)*2 Device with input Pink *3 The FS-N13N/N14N has a white cable as separate
circuit

impedance 10 kΩ
or more output 2.
Overcurrent

Orange
protection
circuit

Load (Short-circuit current PLC, etc.


5-30VDC
Black*3 (Control output) 1 mA or less) Blue*1
0V
0V
Blue*1

FS-N11P / N12P / N13P / N14P / N13CP / N14CP


Output Circuit Diagram Input Circuit Diagram (FS-N13P/N14P only)
2 4
12-24VDC 1
12-24VDC
Brown*1 M8 connector pin layout 3

Brown c*
Sensor main circuit

Sensor main circuit

1
Overcurrent
protection
circuit

Black f*2 PLC, etc.


Load
*1 FS-N11P/N13P/N13CP only
(Control output) *2 The FS-N13P/N14P has a white cable as separate output
Pink The FS-N13CP/N14CP has pin d as separate output 2.
(Short-circuit
Blue e*1 current 2 mA
0V
or less)

FS-N11CN / N12CN
Output Circuit Diagram Input Circuit Diagram
2 4
c* M8 connector pin layout 1 3
3.3VDC
12-24VDC
Sensor main circuit

Sensor main circuit

f d * FS-N11CN only
Overcurrent
protection

Load 5-30VDC
circuit

PLC, etc.
(Short-circuit current
1 mA or less) e*
e* 0V
0V

FS-N11CP / N12CP
Output Circuit Diagram Input Circuit Diagram
2 4
c* 12-24VDC M8 connector pin layout 1 3
c*
12-24VDC
Sensor main circuit

Sensor main circuit

* FS-N11CP only
Overcurrent
protection

PLC, etc.
circuit

f
Load d
(Short-circuit
current 2 mA
0V
or less)
e*

Socket Cable (sold separately)


For FS-N11CN / N11CP / N12CN /N12CP / Pin – wire color
N13CP / N14CP Connected pin number Core wire cover color
OP-73864 2 4 c Brown
(Cable length: 2 m 6.56') 1 3

OP-73865
d White
(Cable length: 10 m 32.81') e Blue
f Black

Digital Fiber Sensor FS-N Series > Circuits 25


D ime nsions
Unit: mm inch

FS-N11N / N11P / N13N / N13P / N11MN FS-N12N / N12P / N14N / N14P


Main unit (lead wire type) Expansion unit (lead wire type)

ø3.9 ø0.15", 3-core x Brown/Blue/Black: 0.34 mm2* ø2.6 ø0.10", 1-core x Black: 0.34 mm2 *1
Cable length: 2 m 6.56' Cable length: 2 m 6.56'

0.39" 9.8 0.39" 9.8

MAX
170°
(Maximum
3.4 (Maximum 3.4 0.13"
when the cover
0.13" when the cover
is opened)
is opened)
100 3.94"
100 3.94"
0.16" 0.16"
4 30.3
4
1.19" (35.3) 30.3
(35.3) (1.39") 1.19"
(1.39")
(13) (0.51") (13) (0.51")

6.7 20.7 35.4 6.7


0.26" 20.7 35.4
0.82" 1.39" 0.26"
0.82" 1.39"
71.8 min. 8 0.32" 71.8 min. 7
2.83" 2.83" 0.28"*2
* FS-N11MN: ø3.9 ø0.15", 4-core x Brown/Blue: 0.34 mm2 Black/Orange: 0.18 mm2 *1 FS-N14N/N14P: ø3.9 ø0.15", 3-core x Black/White/Pink: 0.18 mm2
FS-N13N/N13P: ø3.9 ø0.15", 5-core x Brown/Blue: 0.34 mm Black/White/Pink: 0.18 mm2
2
*2 FS-N14N/N14P: min. 8 0.32"

When the mounting bracket is attached When several units are connected End unit
(OP-73880 sold separately)
(OP-26751 sold separately)
End unit End unit *1
30.3
0.24" 6
1.19"
(38.5) Number of L
(1.52") units (mm inch)
(17.3) 1 9.8 0.39"
(0.68") 2 19.6 0.77" DIN-rail mounting
3 29.4 1.16"
4 39.2 1.54"
3.8 22.9 6.5 (22.6) 20.8
2-ø3.4 ø0.13" 5 49.0 1.93"
0.15" 0.90" 0.26" (0.89") 0.82"
6 58.8 2.32"
25.7 25.4 Spot facing: ø6.4 ø0.25", d=2.7 0.11" 7 68.6 2.70"
1.01" 1.00" 8 78.4 3.09"
9 88.2 3.47"
Rear of 10 98.0 3.86" 9.2 35.4
2-(4.4 x 3.4)(0.17" x 0.13")
mounting 11 107.8 4.24" 0.36"
53.8
1.39"
bracket Spot facing: ø7.2 ø0.28", d=3.2 0.13" 12 117.6 4.63" 2.12"
13 127.4 5.02"
14 137.2 5.40"
9.8 0.39"
15 147.0 5.79"
16 156.8 6.17"
17 166.6 6.56"
15 6 L 6
0.59" 0.24" 0.24"
31 *1 When using expansion units, be sure to use the end unit. (Optional)
1.22"

26
Unit: mm inch

FS-N11CN / N11CP / N13CP FS-N12CN / N12CP / N14CP


Main unit (M8 connector type) Expansion unit (M8 connector type)

0.39" 9.8 ø8.6 ø0.34" 0.39" 9.8 ø8.6 ø0.34"

MAX
170°

(Maximum 3.4 (Maximum 3.4 0.13"


when the cover 0.13" when the cover
is opened) is opened)
100 3.94" 100 3.94"
0.16" 0.16"
4 4 30.3
30.3
1.19" (35.3) 1.19"
(35.3) (1.39")
(1.39") (15.5)(0.61") (15.5)(0.61")

6.7 M8 0.32" 6.7 M8 0.32"


0.26" 20.7 35.4 0.26" 20.7 35.4
connector connector
0.82" 1.39" 0.82" 1.39"
71.8 9.5 71.8 9.5 0.37"
2.83" 0.37" 2.83"

M8 socket cable (separately sold option) ø3.7 ø0.15", 4 -core x 0.28 mm2
Cable length L (m foot)
ø9.5
ø0.37"
OP-73864 2 6.56'
(26.7)
OP-73865 10 6.56' (1.05")
L

When the mounting bracket is attached When several units are connected End unit
(OP-73880 sold separately)
(OP-26751 sold separately)
End unit End unit *1
30.3 0.24" 6
1.19" (38.5)
(1.52") Number of L
(18.8) units (mm inch)
(0.74") 1 9.8 0.39" DIN-rail mounting
2 19.6 0.77"
3 29.4 1.16"
3.8 22.9 6.5 4 39.2 1.54" (22.6) 20.8
0.15" 0.90" 0.26" 2-ø3.4 ø0.13" 5 49.0 1.93" (0.89")0.82"
25.7 25.4 6 58.8 2.32"
Spot facing: ø6.4 ø0.25", d=2.7 0.11"
1.01" 1.00" 7 68.6 2.70"
8 78.4 3.09"
Rear of 9 88.2 3.47" 9.2 35.4
mounting 2-(4.4 x 3.4)(0.17" x 0.13") 10 98.0 3.86" 0.36" 53.8 1.39"
bracket Spot facing: ø7.2 ø0.28", d=3.2 0.13" 11 107.8 4.24" 2.12"
12 117.6 4.63"
13 127.4 5.02"
9.8 0.39" 14 137.2 5.40"
15 147.0 5.79"
16 156.8 6.17"
15 17 166.6 6.56"
0.59"
31
1.22"

6 L 6
0.24" 0.24"
*1 When using expansion units, be sure to use the end unit. (Optional)

Digital Fiber Sensor FS-N Series > Dimensions 27


New! Improved
FIBER CUTTER
Leaves a clean cut edge which
prevents uneven light intensity.
The new cutter comes with the FS-N Series (amplifier). The cutter
included with the fiber unit will be phased out from the old type to the
new type. Once the changeover is complete, cutters will no longer be
included with amplifier units.

Current
design

NEW
OP-0237

OP-87098

CALL T O C O N TA C T Y O U R L O C A L O F F I C E
SAFETY INFORMATION
TOLL
FREE
1-888-KEYENCE
1 - 8 8 8 - 5 3 9 - 3 6 2 3
www.keyence.com Please read the instruction manual carefully in
order to safely operate any KEYENCE product.

KEYENCE CORPORATION OF AMERICA


Corporate Office 50 Tice Blvd., Woodcliff Lake, NJ 07677 PHONE: 201-930-0100 Fax: 201-930-0099 E-mail: keyence@keyence.com
■ Regional offices CO Denver IN Indianapolis MI Detroit NJ Woodcliff Lake OH Cincinnati SC Greenville VA Richmond
AL Birmingham FL Tampa KS Kansas City MI Grand Rapids NY Rochester OH Cleveland TN Nashville WA Seattle
CA N.California GA Atlanta KY Louisville MN Minneapolis NC Charlotte OR Portland TN Knoxville
CA Los Angeles IL Chicago MA Boston MO St. Louis NC Raleigh PA Philadelphia TX Dallas

KEYENCE CANADA INC. KEYENCE MEXICO S.A. DE C.V.


Head Office PHONE: 905-696-9970 Fax: 905-696-8340 E-mail: keyencecanada@keyence.com PHONE: +52-81-8220-7900 Fax: +52-81-8220-9097
Montreal PHONE: 514-694-4740 Fax: 514-694-3206 E-mail: keyencemexico@keyence.com
KEYENCE GLOBAL HEADQUARTERS
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: +81-6-6379-2211 KA1-1010

The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice.
Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved. FSN-KA-C-E 1030-2 611307 Printed in Japan