Sei sulla pagina 1di 14

Model: HGP-310 T6 LPG

INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

WATER COOLED

THREE PHASE

60 Hz

NOT REQUIRED

LPG

Generating Rates
SERVICE PRP STANDBY

Power kVA 311 345


1
Power kW 249 276
Rated Speed r.p.m. 1.800
Standard Voltage V 480/277
Available Voltages V 208/120 – 220/127 – 380/220 – 440/254
Rated at power factor Cos Phi 0,8

HIMOINSA, company with quality certification ISO 9001


HIMOINSA gensets and cogenerations are compliant with EC mark which includes the following directives:
• 2006/42/CE Machinery safety.
• 2006/95/EC Low voltage.
• 89/336/EEC Electromagnetic compatibility.
• 2000/14/EC Sound Power level. Noise emissions outdoor equipment. (amended by 2005/88/EC).
• 97/68/EC Emissions of gaseous and particulate pollutants. (amended by 2002/88/EC & 2004/26/EC).
• EN 12100, EN 13857, EN 60204.
Ambient conditions of reference: 1000 mbar, 25ºC, 30% relative humidity. Power according to ISO 3046 normative.
CONTINUOUS POWER (COP) – ISO 8528: it is defined as being the maximum power which the generating set is capable of delivering continuously whil st supplying a constant electrical load
when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the
manufacturer.
PRIME POWER (PRP) - ISO 8528: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a vari able electrical load when
operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer.
The permissible average power output over 24 h of operation shall not exceed 70 % of the PRP.
STANDBY POWER (ESP) - ISO 8528: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical power
sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per
year with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible avera ge power output over 24 h of operation shall not exceed 70 % of
the ESP.
HIMOINSA HEADQUARTERS:
Ctra. Murcia - San Javier, Km. 23,6 | 30730 SAN JAVIER (Murcia) Spain
Tel.+34 968 19 11 28 Fax +34 968 19 12 17 Fax +34968 19 04 20 info@himoinsa.com www.himoinsa.com
Manufacturing facilities: SPAIN • FRANCE • INDIA • CHINA • USA • BRASIL
Subsidiaries:
ITALY | PORTUGAL | POLAND | GERMANY | SINGAPORE | UAE | MEXICO | PANAMA | ARGENTINA | ANGOLA | UK

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Engine

PRP STANDBY

Rated Output kW 299 352


Manufacturer PSI
Model 21.9L
Rated Speed r.p.m. 1.800
Fuel LPG
Engine Type 4 otto-cycle
Ignition System Spark plug ignition
Aspiration Type Turbocharged and intercooled
Cylinders Arrangement 12 - V
Bore and Stroke mm 128 x 142
Displacement l 21,9
Cooling System Liquid
Compression Ratio 10,5 : 1
2
Governor Type Electronic
Air Filter Type Dry

Alternator

Poles Num 4
Winding Connections (standard) Star
Frame Mounting S-1 14"
Insulation Class H class
Enclosure (according IEC-34-5) IP23
Exciter System self-excited, brushless
Voltage Regulator A.V.R. (Electronic)
Bearing Single bearing
Coupling Flexible disc
Coating type Standard (Vacuum impregnation)

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Cooling system

Air Flow (Combustion + Cooling) m³/h 69.600


Engine + Radiator Coolant Capacity l 228
Coolant Flow m³/h 39,6

Exhaust system

Exhaust Flow at Rated kW m³/h 5.088


Exhaust Temperature at Rated kW °C 750
Maximum Back Pressure kPa 10,2
Exhaust Flange Size mm 200
3

Lubrication system

Lube Oil Specifications SAE 15W-40 - API CD/CF


Lube Oil Capacity with filters l 47,1

Air inlet system

Intake Air Flow m³/h 1.620


Cooling Air Flow m³/h 67.980

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Starting system

Starting Motor Kw 7
Recommended Battery Capacity Ah 200
Auxiliary Voltage Vcc 24

Fuel system

LPG Specifications * Refer to manual


Fuel Consumption StandBy kg/h 77,1
Fuel Consumption 100% PRP kg/h 69,6
Fuel Consumption 75 % PRP kg/h 53,3
Fuel Consumption 50 % PRP kg/h 35,9 4
Fuel Supply Connection Size inches 2
Standard Fuel Supply Pressure mbar 30-300
Auto Fuel Lock-Off Double Solenoid Valve Standard
*Based on LPG with LHV = 12,6 kWh/kg.

Sound data

Sound pressure level dB(A)@7m 68 ± 2,3

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Control Panel

F U N C IO N A L IT Y P ANE L MODE L C ONTR OL L E R MODE


Auto-start M5 CEM7

Automatic Control Panel without Grid Control AS5 CEM7**

Automatic Control Panel with Grid Control


AS5 CEA7
(customer change over contactors)
Automatic Control Panel with Grid Control
AS5XCC2 CEM7+CEC7
5
(Himoinsa change over contactor with display)
Automatic Grid Failure (wall mounted panel) AC5 CEA7

(**) Pre-heating resistance in the Genset and battery charger in the control panel included.
Option available: Auto-start control panel without circuit breaker

General Description
CEM7 CEC7 CEA7
The CEM7 controller unit is a device able to The CEC7 controller unit is a net sings supervision CEA7 controller is a supervision
control de operation, monitoring and protection equipment, and control and supply supplier through equipment for mains signal and also a
of a generating set. The controller unit consists generating set. The controller unit consists of 2 different supervision and electrical supply through
of 2 different modules: modules: the genset. This controller is composed
1. The VISUALIZATION module 1. The VISUALIZATION module by 2 different modules:
2. The MEASUREMENTS module 2. The MEASUREMENTS module 1. VISUALIZATION module
2. MEASUREMENTS module
VISUALIZATION MODULE VISUALIZATION MODULE
Provides information about the status of the device The visualization module provides information about the VISUALIZATION MODULE
and, at the same time, allows the user to interact status of the device and, at the same time, allows the The visualization module provides information about the
with it. It consists on a backlit display and various user to interact with it. With this visualization module the status of the device and, at the same time, allows the
LEDs for monitoring the status of the controller and user is able to control, program and configure the user to interact with it. With this visualization module the
buttons that allow the user to control, program and functions of the unit. It consists on a backlight display user is able to control, program and configure the
configure the functions of the unit. and various LEDs for monitoring the status of the functions of the unit.
controller and buttons that allow the user to control,
MEASUREMENTS MODULE program and configure the functions of the unit.
Controls and monitors the control board. It is MEASUREMENTS MODULE
located in the rear part of the panel, in order to The measurements module controls and monitors the
MEASUREMENTS MODULE
reduce the wiring and to avoid electromagnetic control board. It is located in the rear part of the panel, in
The measurements module controls and monitors the
disturbances. Every signal, sensor and actuator is order to reduce the wiring and to avoid electromagnetic
control board. It is located in the rear part of the panel, in
connected to this module. The connexion between disturbances. Every signal, sensor and actuator is
order to reduce the wiring and to avoid electromagnetic
the visualization module and the measurements connected to this module. Connection between the
disturbances. Every signal, sensor and actuator is
module is made with a CAN communication bus. measure module and visualization mode is made by
connected to this module. The connection between the
This feature allows the intercommunion of other means of a CAN BUS (Communication Bus).This produces
measure module and visualization mode is made by
modules to the main controller with a scalability an interconnection between additional modules which
means of a CAN BUS (Communication Bus).This produces
warranty. guarantees the proper working of the controller.
an interconnection between additional modules which
guarantees the proper working of the controller.

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Control & Power Panel


1. CM Control Panel.
2. CP Power Panel.
3. On/Off Switch.
4. Emergency Stop.
5. Main Line Circuit Breaker for overload protection.
6. Main bus /hardwire connection panel with safety protection.

CE-7 Auto-start multilingual control panel


1. Voltage between each Phase & Neutral
2. Voltage between Phases
3. Current (amps) on each Phase
4. Frequency
5. Active, Aparent & Reactive Power
6. Power Factor
7. Instant Power (kWh) and Accumulative power)
8. Fuel On/Off
9. Oil pressure, coolant temperature, oil temperature
10. Battery voltage, battery charging alternator voltage
11. Engine Speed
6
12. Hours running
13. Multilingual (Spanish, English, French, Italian, Portuguese, Polish, German, Chinese, Russian, Swedish, Norwegian)

Engine Alarms Genset Alarms Grid Alarms


1. High coolant temperature. 1. Overload. 1. Maximum Mains Voltage.
2. Low oil pressure. 2. Unbalanced voltage. 2. Minimum Mains Voltage.
3. Battery charge alternator. 3. Over-voltage. 3. Maximum Mains Frequency.
4. Start failure. 4. Under-voltage. 4. Minimum Mains Frequency.
5. Low water level. 5. Over-frequency. 5. Mains phase sequence failure.
6. Fuel supply. 6. Under-frequency. 6. Mains power failure.
7. Over-speed. 7. Overload. 7. Mains contactor switching failure.
8. Under-speed. 8. Short circuit.
9. Low battery voltage. 9. Inverse Power.
10. High coolant temp. by sensor. 10. Asymmetry among phases.
11. Low oil pressure by sensor. 11. Genset contactor Failure.
12. Low pressure fuel by sensor.
13. Unexpected shutdown.
14. Stop failure.
15. Low engine temperature.
16. Genset voltage drops.
17. Emergency stop.

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Control Features

CEM 7 CEC 7 CEA 7 CEM7 + CEC7


GENERATOR READINGS
Voltage among phases • • • •
Voltage among phases and neutral • • • •
Amperage • • • •
Frequency • • • •
Apparent power (kVA) • • • •
Active power (kW) • • • •
Reactive power (kVAr) • • • •
Power factor • • • •

GRID READINGS
Voltage among phases x • • •
Voltage among phase and neutral x • • •
Amperage x • • •
Frequency x • • •
Aparent power x x • •
Active power x x • •
Reactive power x x • •
Power factor x x • •

ENGINE READINGS
Coolant temperature • x • •
Oil pressure • x • •
Fuel On/Off • x • •
Battery voltage • x • • 7
R.P.M. • x • •
Battery charge alternator voltage • x • •

ENGINE PROTECTIONS
High water temperature • x • •
High coolant temperature by sensor • x • •
Low engine temperature by sensor • x • •
Low oil pressure • x • •
Low oil pressure by sensor • x • •
Low coolant level • x • •
Unexpected shutdown • x • •
Fuel storage • x • •
Fuel storage by sensor • x • •
Stop failure • x • •
Battery voltage failure • x • •
Battery charge alternator failure • x • •
Overspeed • x • •
Underspeed • x • •
Start failure • x • •
Emergency Stop • • • •

ALTERNATOR PROTECTIONS
High frequency • • • •
Low frequency • • • •
High voltage • • • •
Low voltage • • • •
Short-circuit • x • •
Asymmetry among phases • • • •
Incorrect phase sequence • • • •
Inverse power • x • •
Overload • x • •
Genset signal droop • • • •

• Standard x Not Included • Optional

NOTE: All protections are programmable to make “warning” or “stop with cooling time” or “without”.

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Control Features

CEM 7 CEC 7 CEA 7 CEM7 + CEC7


COUNTERS
Total hour counter • • • •
Partial hour counter • • • •
Kilowatt meter • • • •
Starts valid counters • • • •
Starts failure counters • • • •
Maintenance • • • •

COMUNICATIONS
RS232 • • • •
RS485 • • • •
Modbus IP • • • •
Modbus • • • •
CCLAN • x • •
Software for PC • • • •
Analogic modem • • • •
GSM/GPRS modem • • • •
Remote screen • x • •
Telesignal •(8+4) •(8+4) •(8+4)
J1939 • x • •

FEATURES
Alarms history (10) / (•+100) -10 (10) / (•+100) (10) / (•+100)
External start • • • •
Start inhibition • • • • 8
Mains failure start •(CEC7) • • •
Start under normative EJP • x • •
Genset contactor activation • x x •
Main & Genset contactor activation x • • •
Fuel supply control • x • •
Engine temperature control • x • •
Manual override • x • •
Programmable alarms • x • •
Genset start function in test mode • x • •
Programmable outputs • x • •
Multilingual • • • •

SPECIAL FUNCTIONS
Positioning GPS • • •
Synchronization with mains • • •
Mains Synchronism • • •
Second Cero suppression • • •
RAM 7 • • •
Remote screen • • •
Timer • • •

• Standard x Not Included • Optional

CEC7: available when the controller CEC7 is incorporated to the installation.


MPS 5.0: available application when the module MPS 5. has been incorporated to the panel.

Note: AS5 + CC2 configuration, will have all CEM7 functionality plus CEC7 mains readings.

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN
Control Panel Model
M5
Digital manual auto-start control panel and thermal magnetic protection (according to voltage and phase) and
differential relay. CEM7

AS5
Automatic control panel WITHOUT ATS (Automatic Transfer Switch) and WITHOUT mains control with CEM7. (*) As optional AS5
with CEA7. Automatic control panel without ATS (automatic transfer switch) and with mains control.

CC2
Himoinsa External ATS WITH visualization display. CEC7

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Control Panel Model

AS5 + CC2
Automatic with mains control and ATS with visualization. The visualization will be in the genset and in the ATS box. CEM7+CEC7

10

AC5
Automatic Mains Failure control panel. Wall mounted Automatic control panel including transfer switch with thermal magnetic
protection (according to voltage and phase). CEA7

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Standard and Optional Features

Engine
· LPG engine
· 4 strokes cycle
· Water-cooled
· 24V Electrical system
· Radiator with blowing fan
· Water separator decanting filter (no visible level)
· Electronic governor
· Sender WT
· Senders OP
· Dry air cleaner
· Hot components and radiator guards
· Mobile components guards

Alternator
· Self-excited and Self-regulated
· 4 poles
· AVR governor
· IP23 protection degree
· Insulation H class
11
· Single drive-shaft
· Flexible disc coupling

Electrical system
· Control and power electric panel, with measurements devices and controller (according to necessity and configuration)
· 4 poles circuit breaker
· Earth leakage protection adjustable (time & sensibility) standard in M5 and AS5 configuration with MCCB
· Battery charger (standard on automatic control panels)
· Pre-heating resistance (standard on automatic control panels) / water jacket heater
· Battery charge alternator with ground connection
· Starting battery/ies installed and connected to the engine (supports included)
· Ground connection electrical installation with connection ready for ground pike (not supplied)

Optional :
· Battery disconnector

Gas Train
· Ball valve
· Gas filter
· Double solenoid valve
· Gas pressure regulator
· Valve testing system
· Low pressure switch

Optional :
· Medium and high pressure regulator
· High pressure switch

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Standard and Optional Features

Soundproofed version
· Oil sump extraction kit
· Versatility to assemble high capacity metallic oil tank chassis
· Steel made chassis
· Anti-vibration shock absorber
· Emergency stop button
· Sound attenuated canopy made of high quality steel metal
· High mechanical strength
· Low noise level
· Attenuation through high density rock wool material
· Powder coating
· Easy access for service maintenance
· Reinforced lifting eye to lift by crane
· Bunded chassis (works as liquids retention tray)
· Drain chassis cap
· Chassis ready for future mobile kit installation
· Steel made residential silencer -35dB (A) attenuation

Optional:
· Supplementary oil system with pump

12

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

Weight & Dimensions

WEIGHT AND DIMENSIONS


5.960
13
Length (L) mm
Height (H) mm 2.795
Width (W) mm 2.640
Shipping Volume Seaworthy (standard supplier) m³ 43,98
* 8.994
Wet Weight kg
(*) (with standard accesories)

Himoinsa reserves the right to modify any characteristic without prior notice.
Weights and dimensions based on products standard.
Illustrations may include optional equipment.
Technical data described here correspond with the available information at the moment of printing. Industrial design under patent

Local Distributor

Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 191128 / +34 968 191 128
Fax: +34 968 191 217 | Export Fax +34 968 190 420 | E-Mail: info@himoinsa.com | www.himoinsa.com
Model: HGP-310 T6 LPG
INDUSTRIAL RANGE
SoundProof
Powered by PSI-DOOSAN

PDF Summary
Created : 04/03/2016 13:10
Author : HIMOINSA
Number of pages : 14
Report Type: Data Sheet - Industrial gas range
Generated by: HIMOINSA Engineering Dept.

Page 1. Genset data


Page 2. Engine & Alternator Specifications
Page 3. Cooling, Exhaust, Lubrication and Air Inlet systems
Page 4. Starting and Fuel systems.
Page 5. Control Panels & Description
Page 6. Control box and power, CE7 Panel, Alarms
Page 7. Controller features (I)
Page 8. Controller features (II)
Page 9. Control Panel Model
Page 10. Control Panel Model
Page 11. Standard & Optional Features
Page 12. Standard & Optional Features
Page 13. Dimensions 14
Page 14. PDF Summary