Sei sulla pagina 1di 12

SPECTRUM ANALYZERS

SPECTRUM ANALYZER OVERVIEW FREQUENCY RANGE

Spectrum analyzer is the most widely applied measuring Selecting a spectrum analyzer for a measurement requires
instrument for wireless communications devices, components or selecting its frequency range, like 1GHz, 2.4GHz, and so on.
systems. It measures and displays the frequency spectrum Therefore the frequency range is the first consideration for most
distribution of an RF signal. Spectrum analyzer can measure applications.
and read both frequency and amplitude information. Nowadays,
digital communications dominate wireless communications
systems. Despite the dominance of digital communications,
measuring a frequency spectrum by a spectrum analyzer is
still considered an important process.

To choose the right spectrum analyzer, several key specifications


should be considered, which are explained below.

Figure 1, Frequency Range

NOISE FLOOR SPURIOUS NOISE


Noise floor is the bottom noise level when no signal is fed into Circuit noise or interference that looks like a signal occurs even
spectrum analyzer. It represents the lowest signal level that without an input signal due to spurious noise of spectrum

SPECTRUM ANALYZERS
spectrum analyzer can measure. The noise floor usually analyzer. Unlike noise floor, spurious noise presents itself
depends on Resolution Bandwidth (RBW). like a signal with a specific frequency.

SPECTRUM ANALYZERS

GW Instek spectrum analyzer lineup fits a broad range of applications in research and design, service and maintenance, manufacturing, Figure 2, Noise Floor Figure 3, Spurious Noise
educational and other related fields for the frequency requirements ranging from 1GHz to 3.25GHz. Many features are designed to
perform higher stability measurements, further signal analysis and more efficient measurement. The topographic and spectrogram HARMONICS PHASE NOISE
display modes are developed to illustrate the signal in color shade to perform signal persistence and time progress. The SEM, ACPR,
OCBW, TOI, Harmonic, CNR, CTB, CSO measurements, frequency counter and many other measurement functions are provided as Spectrum analyzer itself also generates harmonics from an Phase noise shows the purity of a signal. In Figure 5a, there
input signal. Therefore if the harmonics generated by a spectrum are two signals with different levels of phase noise. The lower
well. The sequence function can create and perform a series of measurement steps without connecting with the PC. The most
analyzer are greater than the harmonics from an input signal, the one is purer than the upper one, and therefore it has better
common interface such as LXI is included for remote control. GW Instek provides the most cost-effective options in RF measurements. harmonic measurement will result in an error as Figure 4 presents. phase noise performance.
a.Signals with different phase noises b.Definition of phase noise

PRODUCTS

3 . 25GHz Spectrum Analyzer


3GHz Spectrum Analyzer

1GHz Spectrum Analyzer

Figure 5 : Phase Noise


Figure 4, Harmonic Error Because of Greater
Harmonic of Spectrum Analyzer Figure 5b shows the definition of phase noise. It is usually
defined as dBc with a frequency offset. For example,"-50dBc at
200kHz offset with 30kHz RBW". Refer to the Q&A to see the
relationship between phase noise and RBW.

B1 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B2
SPECTRUM ANALYZERS SPECTRUM ANALYZERS
MODEL GSP-9330 GSP-9300B GSP-730
THIRD ORDER INTER-MODULATION DYNAMIC RANGE Frequency Range 9kHz ~ 3GHz 9kHz ~ 3.25GHz 150kHz ~ 3GHz
Frequency Stability ±1ppm max. (per year) ±1ppm max. (Per Year)
Third order inter-modulation occurs with a two-tone input signal, a signal Different companies use different definitions for dynamic range, but Over Temperature Frequency Stability ±0.025 ppm (0 ~ 50 °C) ±0.025 ppm (0 ~ 50 °C)
with two frequencies or two signals with different frequencies that are fed actually they all point to the same thing; the ability to accurately measure RBW Range 1Hz~1MHz in 1-3-10 sequence 1Hz~1MHz in 1-3-10 Sequence
into a spectrum analyzer at the same time. When the input signal 30k, 100k,300kHz, 1MHz
amplitude. Considering the specifications introduced above, the dynamic 200Hz, 9kHz, 120kHz, 1MHz 200Hz, 9kHz, 120kHz, 1MHz
frequencies are f1 and f2, the harmonics are as follows. for EMI Filter for EMI Filter
(30kHz Range is not Adjustable)
range might actually include more than one term. For example, if a two-
Input output tone signal is under measurement, the inter-modulation distortion needs Video Bandwidth 1Hz~1MHz in 1-3-10 sequence 1Hz~1MHz in 1-3-10 Steps
f1, f2 fundamentals f1,f2 to be considered. If the input signal frequency falls onto the spurious Phase Noise -88dBc/Hz @1GHz, 10kHz offset -88dBc/Hz @1GHz, 10kHz Offset -85dBc/Hz @1GHz, 500kHz Offset
2nd order harmonics 2f1, 2f2, f1±f2, noise, it will limit the dynamic range. But generally speaking, dynamic Noise Floor -139dBm @1GHz, 10Hz RBW, per-amp on -139dBm @1GHz, 10Hz RBW, Per-amp on -100dBm @1GHz, 30kHz RBW
3rd order harmonics 3f1, 3f2, 2f1±f2, 2f2±f1 range is defined as the level between noise floor and the maximum Amplitude Measurement Range -142dBm ~ +30dBm @Pre-amp on -142dBm ~ +30dBm @Pre-amp on -100dBm ~ +20dBm
---- ---- measurable level. Alternatively, sometimes the display range (80 or Overload Protection +30dBm, ±50VDC +30dBm, ±50VDC +30dBm, ±25VDC
The third order harmonics are the primary concerns in a system. If the 100dB) is called dynamic range. It describes the range within the display -110dBm ~ +30dBm -110dBm ~ +30dBm
Reference Level Range -40dBm ~ +20dBm
frequencies of f1 and f2 are very close, then 2f1-f2 and f1-2f2 will also be very without shifting the reference level. The entire concept is illustrated in
close to the original signal. It will be difficult for the subsequent filters to Input Attenuator 0 ~ 50dB, in 1 dB Steps 0 ~ 50dB, in 1 dB Steps
Figure 7.
filter out the harmonics accordingly. The concepts are illustrated in Figure 6. Pre-amplifier Built-in 18dB Internal Built-in 18dB Internal
Gate Sweep Yes Yes
f1 f2
Frequency Counter Support , Min. resolution 1Hz Support , Min. resolution 1Hz
BPF Measurement Function ACPR, OCBW, CHPW
f1, f2 SEM, ACPR, OCBW, CHPW, N-dB BW, SEM, ACPR, OCBW, CHPW, N-dB BW,
Phase Jitter, Demod. Analyzer, Harmonic, Phase Jitter, Demod. Analyzer, Harmonic,
TOI, CNR, CSO, CTB, P1dB, TDP TOI, CNR, CSO, CTB, P1dB, TDP
2f1 - f2 2f2- f1 Non-Harmonic Spurious
Trace 4 Traces 4 Traces 3 Traces
Figure 6: Third Order Harmonics of 2f1-f2 and 2f2-f1 3 rd Order Intermodulation
Amplitude Positive-peak, negative-peak, sample, Positive-peak, negative-peak, sample,
SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
Trace Detect Mode normal, RMS(not Video), Quesi-Peak, Average
An example is expressed in Table 1. Linearity 2 nd Order Harmonic normal, RMS(not Video)
within 100dB
Harmonics 1 2 3 Display Marker 6 6 5
100, 110 100, 110 ... 300, 330, 310, 320, 90, 120 Memory Save/Recall 16MB Nominal 16MB Nominal 5 Memories
Input
100, 101 100, 101 ... 300, 303, 301, 302, 99, 102
Frequency Display Modes Spectrogram, Topographic, Spectrum Spectrogram, Topographic, Spectrum Spectrum Mode
100, 100.1 100, 100.1 ... 300, 300.3, 300.1, 300.2, 99.9, 100.2 Shifting by Split-Window Yes Yes Yes
Ref. Level
Table 1 : Two-Tone Signal Harmonics Sequence Yes Yes
Limit Line Yes Yes Yes
In case the input signal frequencies are 100 and 100.1, their 3rd order
Noise floor
harmonics will be 99.9 (2f1-f2) and 100.2 (2f2-f1). Using that example it is Correction Table Yes Yes
easy to see that the third order harmonics are close to the original signals, 8.4 Inchs Color TFT LCD with SVGA 8.4 Inchs Color TFT LCD with SVGA 5.6 Inchs Color TFT LCD with
which will pose challenges for designing the subsequent filters. Therefore Figure 7 : Dynamic Range Display
(800 x 600) (800 x 600) VGA (640 x 480)
the inter-modulation distortion of spectrum analyzer itself might limit
Tracking Generator 100kHz ~ 3.25GHz (Optional) 100kHz ~ 3GHz (Optional)
the ability of two-toned signal measurements.
Power Meter
Demodulator Yes, with AM/FM/ASK/FSK Analysis Yes, with AM/FM Analysis
APPLICATION
IF Output Yes, 886MHz, -25dBm Yes, 886MHz, -25dBm
DC Power Operation
Battery Power Operation Yes Yes
USB Interface Yes Yes Yes
Wireless Speaker RS-232C Interface Yes Yes Yes

EMI Debug GPIB Interface Optional Optional


SNG Car Micro SD Socket Yes Yes
LAN Port Yes, with LXI Standard Yes, with LXI Standard
VGA Output Yes, DVI-I, 800 x 600 Yes, DVI-I, 800 x 600 Yes, 15 pin D-sub, 640 x 480
Tuner
Rack Adapter Panel Yes, GRA-415 Yes, GRA-415
Remote Control Power Source AC100 ~ 240V, 50 ~ 60Hz AC100 ~ 240V, 50 ~ 60Hz AC100 ~ 240V, 50 ~ 60Hz
Page B5-12 B13-16 B17-22

Antenna RF & SPECTRUM ANALYZER TRAINING SYSTEM


SPECTRUM ANALYZERS Tire Pressure Monitoring MODEL GRF-1300 GRF-1300A
System (TPMS)
Collocation Instrument GSP-730 GSP-730
Necessary Option USG-LF44

Mobile Phone RF Cable SMA Cable SMA Cable


RF Connector SMA Female SMA Female
GPS Receiver
Interface USB Device USB Device

Wireless RFID Power Source AC100 ~ 240V, 50 ~ 60Hz AC100 ~ 240V, 50 ~ 60Hz
Microphone WLAN
Page B17-22 B17-22

B3 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B4
3.25GHz Spectrum Analyzer
GSP-9330, a high test speed spectrum analyzer with 3.25 GHz, provides the fastest 204 ms sweep
speed. Users, via high speed sweep time, can easily handle and analyze modulation signals. The Rear Panel
keys to handling modulated signals are fast sweep time and signal demodulation functions. In
addition to the analog AM/FM demodulation and analysis function, GSP-9330 also provides digital
signal ASK/FSK, and 2FSK demodulation and analysis capabilities. Nowadays, EMC issues are very
crucial to product's design processes. Therefore, GSP-9330 has incorporated the EMC pretest
solution to facilitate EMC tests. The simple and easy EMC pretest procedures from GSP-9330 can
tremendously shorten users' product launch timeline.

GSP-9330 GRA-415 Rack Adapter Panel


For : GSP-9330/9300, Rack Mounting (19", 6U)
LXI
GSP-9330
GSP-9330

GSP-9330
FEATURES
SPECIFICATIONS SPECIFICATIONS
* Frequency Range : 9kHz ~ 3.25GHz FREQUENCY DISPLAYED AVERAGE NOISE LEVEL (DANL)
* 0.025ppm Frequency Stability and 1ppm FREQUENCY Preamp off 0 dB attenuation; RF Input is terminated with a 50W load. RBW 10 Hz; VBW 10 Hz;
Aging Rate span 500 Hz; reference level = - 60 dBm; trace average 40
Range 9 kHz ~ 3.25 GHz
* RBW : 1Hz ~ 1MHz (3dB), 6dB EMI Filter : Resolution 1 Hz 9 kHz ~ 100 kHz < -93 dBm Nominal
SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
200Hz, 9kHz, 120kHz, 1MHz FREQUENCY REFERENCE 100 kHz ~ 1 MHz < -90 dBm - 3 x (f/100 kHz) dB Nominal
* Fastest Sweep Time : 204ms Accuracy ±(period since last adjustment x aging rate)
1 MHZ ~ 10 MHz < -122 dBm Nominal
* Sensitivity : -149dBm/Hz (@PreAmp on) + stability over temperature + supply 2.7 ~ 3.25 GHz < -116 dBm Nominal
* Built-in Preamplifier, 50dB Attenuator, and voltage stability Preamp on 0 dB attenuation; RF Input is terminated with a 50W load. RBW 10 Hz; VBW 10 Hz;
Aging Rate ± 1 ppm max. 1 year after last adjustment span 500 Hz; reference level = - 60 dBm; trace average 40
Sequence Function Frequency Stability ± 0.025 ppm 0 ~ 50 °C
* Built-in EMC Pretest Function Over Temperature 100 kHz ~ 1 MHz < -108 dBm - 3 x (f/100 kHz) dB Nominal
* Built-in 2FSK Analysis, AM/FM/ASK/FSK Supply Voltage Stability ± 0.02 ppm 1 MHZ ~ 10 MHz < -142 dBm Nominal GKT-001 General Kit Set
10 MHZ ~ 3.25 GHz < -142 dBm + 3 x (f/1 GHz) dB Nominal
Demodulation & Analysis FREQUENCY READOUT ACCURACY Include :
LEVEL DISPLAY RANGE
* Built-in P1dB Point, Harmonic, Channel Start, Stop, Center, ±(marker frequency indication x frequency ADP-002
Marker Scales Log, Linear ATN-100
Power, N-dB Bandwidth, OCBW, ACPR, SEM, reference accuracy + 10% x RBW +
Units dBm, dBmV, dBuV, V, W
frequency resolution) GTL-303
TOI, CNR, CTB, CSO, Noise Marker, Trace Points Max. 601 points, Min. 6 points Marker Level Readout 0.01 dB Log scale
GSC-002
Frequency Counter, Time Domain Power, 0.01 % of reference level Linear scale
MARKER FREQUENCY COUNTER Level Display Modes Trace, Topographic, Spectrogram Single/Split Windows For: GSP-Series
Gated Sweep
Resolution 1 Hz, 10 Hz, 100 Hz, 1 kHz Number of Traces 4
* Built-in Spectrogram, Topographic and Accuracy ±(marker frequency indication X frequency RBW/Span >=0.02 ; Mkr level to DNL>30 dB Detector Positive-peak,negative-peak,sample,
Split-window Display Modes reference accuracy + counter resolution) normal,RMS(not Video) GKT-002 CATV Kit Set
* Remote Control EMI Measurement Software : FREQUENCY SPAN Trace Functions Positive-peak,negative-peak,sample,
normal,RMS(not Video),Quasi-Peak(EMI), Include :
SpectrumShot Range 0 Hz (zero span), 100 Hz ~ 3.25 GHz Average(EMI),Clear & Write,Max/ ADP-001
* Remote Control Interface : LAN, USB, RS-232 Resolution 1 Hz Min Hold,View, Blank, Average
Accuracy ADP-101
± frequency resolution1 RBW : Auto
* Options : Tracking Generator, GPIB Interface, ABSOLUTE AMPLITUDE ACCURACY GTL-304
PHASE NOISE Center=160 MHz ; RBW 10 kHz; VBW 1 kHz; span 100 kHz; log scale; 1 dB/div;
Battery Pack Absolute Point GSC-003
Offset from Carrier Fc=1GHz;RBW=1kHz,VBW=10Hz;Average 40 peak detector; 23°C±1°C; Signal at Reference Level For: GSP-Series
10 kHz < -88 dBc/Hz Typical Preamp Off ± 0.3 dB Ref level 0 dBm; 10 dB RF attenuation
100 kHz < -95 dBc/Hz Typical Preamp On ± 0.4 dB Ref level 0 dBm; -30 dB RF attenuation
1 MHz < -113 dBc/Hz Typical
RESOLUTION BANDWIDTH (RBW) FILTER
FREQUENCY RESPONSE GKT-003 RLB Kit Set
Preamp Off Attenuation : 10 dB; Reference: 160 MHz; 20 ~ 30°C Include :
Filter Bandwidth 1 Hz ~ 1 MHz in 1-3-10 sequence -3dB bandwidth 100 kHz ~ 2.0 GHz ± 0.5 dB
200 Hz, 9 kHz, 120 kHz, 1MHz -6dB bandwidth 2GHz ~ 3.25 GHz ± 0.7 dB GAK-001
Accuracy ± 8%, RBW = 1MHz ; ± 5%, RBW < 1MHz Nominal Preamp On Attenuation: 0 dB; Reference: 160 MHz; 20 ~ 30°C GAK-002
Shape Factor 1 MHz ~ 2 GHz ± 0.6 dB GTL-302
<4.5 : 1 Normal Bandwidth ratio: -60dB:-3dB 2 GHz ~ 3.25 GHz ± 0.8 dB GSC-004
VIDEO BANDWIDTH (VBW) FILTER ATTENUATION SWITCHING UNCERTAINTY For: GSP-Series
Filter Bandwidth 1 Hz ~ 1 MHz in 1-3-10 sequence -3dB bandwidth Attenuator Setting 0 ~ 50 dB in 1 dB step
Uncertainty ± 0.25 dB Reference : 160 MHz, 10dB attenuation
AMPLITUDE
RBW FILTER SWITCHING UNCERTAINTY
AMPLITUDE RANGE
1 Hz ~ 1 MHz ± 0.25 dB Reference : 10 kHz RBW GKT-008 EMI Probe Kit Set
Measurement Range 100 kHz ~ 1 MHz Displayed Average Noise Level(DANL)to 18 dBm LEVEL MEASUREMENT UNCERTAINTY Include :
GSC-009 Soft Carrying Case 1 MHz ~ 10 MHz DANL to 21 dBm
10 MHz ~ 3.25 GHz DANL to 30 dBm Overall Amplitude ± 1.5 dB 20 ~ 30°C; frequency > 1 MHz; Signal input ADP-002
For: GSP-9330/9300B Accuracy 0 ~ -50 dBm; Reference level 0 ~ -50 dBm; GTL-303
ATTENUATOR Input attenuation 10 dB; RBW 1 kHz; PR-01
Input Attenuator Range 0 ~ 50 dB, in 1 dB steps Auto or manual setup VBW 1 kHz; after cal; Preamp Off PR-02
± 0.5 dB Typical ANT-04
MAXIMUM SAFE INPUT LEVEL
Average Total Power +33 dBm Input attenuator 10 dB SPURIOUS RESPONSE ANT-05
Second Harmonic Preamp off; signal input -30dBm; 0 dB attenuation For: GSP-Series
DC Voltage ± 50 V
Intercept +35 dBm Typical; 10 MHz < fc < 775 MHz
1 dB GAIN COMPRESSION +60 dBm Typical; 775 MHz  fc < 1.625 GHz
Total Power at 1st Mixer > 0 dBm Typical ; Fc 50 MHz; preamp. off Third-order Intercept Preamp off; signal input -30dBm; 0 dB attenuation
Total Power at the Preamp > -22 dBm Typical ; Fc 50 MHz; preamp. on > 1dBm 300 MHz ~ 3.25 GHz
Input Related < -60 dBc Input signal level -30 dBm, Att. Mode,
Mixer power level (dBm) = input power (dBm) Spurious Att=0dB; 20-30ºC
attenuation (dB) Residual Response <-90 dBm Input terminated; 0 dB attenuation;
(Inherent) Preamp off

B5 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B6
3.25GHz Spectrum Analyzer
SPECIFICATIONS
SWEEP ORDERING INFORMATION GLN-5040A Two Line V-Network GPL-5010 Transient Limiter
SWEEP TIME GSP-9330 3.25 GHz Spectrum Analyzer For: GSP-9330 For: GSP-9330
Range 204ms ~ 1000 s Span > 0 Hz
50 s ~ 1000 s Span = 0 Hz; Min resolution=10 s
Sweep Mode Continuous; Single EMC Pretest Solution : GKT-008 EMI Near Field Probe Set
Trigger Source Free run; Video; External GLN-5040A Line Impedance Stabilization Network
Trigger Slope Positive or negative edge GIT-5060 Isolation Transformer
RF PREAMPLIFIER GPL-5010 Transient Limiter
Frequency Range 1 MHz ~ 3.25 GHz ACCESSORIES :
Gain 18 dB Nominal (installed as standard) Power Cord, Certificate of Calibration, CD-ROM (with Quick Start Guide, User Manual,
FRONT PANEL INPUT/OUTPUT Programming Manual, SpectrumShot Software, SpectrumShot Guide & IVI Driver)
RF INPUT OPTION
Connector Type N-type female Opt.01 Tracking Generator GIT-5060 Isolation Transformer
Impedance 50 Nominal Opt.02 Battery Pack
<1.6 :1
For: GSP-9330
VSWR 300 kHz ~ 3.25 GHz ; Input attenuator 10 dB
Opt.03 GPIB Interface
POWER FOR OPTION
Connector Type SMB male OPTIONAL ACCESSORIES
Voltage/Current DC +7V/500 mA max With short-circuit protection GSC-009 Soft Carrying Case
USB HOST GRA-415 Rack Adapter Panel
Connector Type A plug
Protocol Version 2.0 Support Full/High/Low speed FREE DOWNLOAD
MICRO SD SOCKET SpectrumShot PC Software for Windows System (available on GW Instek website)
Protocol SD 1.1 IVI Driver Supports LabVIEW/LabWindows/CVI Programming (available on NI website)
GSP-9330

GSP-9330
Support Cards Micro SD, Micro SDHC Up to 32GB capacity
REAR PANEL INPUT/OUTPUT
REFERENCE OUTPUT
Connector Type BNC female
Output Frequency 10 MHz Nominal
A. FAST SIGNAL SWEEP
Output Amplitude 3.3V CMOS
Output Impedance 50
REFERENCE INPUT FM Signal Monitoring Taiwan 3G Telecom Signals
Connector Type
SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
BNC female
Input Reference Frequency 10 MHz
Input Amplitude -5 dBm ~ +10 dBm
Frequency Lock Range Within ± 5 ppm of the input reference frequency
ALARM OUTPUT
Connector Type BNC female Open-collector
TRIGGER INPUT/GATED SWEEP INPUT
Connector Type BNC female
Input Amplitude 3.3V CMOS
Switch Auto selection by function
LAN TCP/IP INTERFACE
Connector Type RJ-45 For spectrum analyzer, speed is the most important specification. such as frequency/amplitude modulation signals, Bluetooth frequency
Base 10Base-T; 100Base-Tx; Auto-MDIX
USB DEVICE
GSP-9330 provides sweep speed up to 204 ms. Users, via high speed hopping signals, tuned oscillator or other interfering signals under
Connector Type B plug For remote control only; supports USB TMC sweep time, can identify and analyze various fast or transient signals ISM Band.
Protocol Version 2.0 Supports Full/High/Low speed
IF OUTPUT
Connector Type SMA female
Impedance 50 Nominal B. MODULATED SIGNAL ANALYSIS
IF Frequency 886 MHz Nominal
Output Level -25 dBm 10 dB attenuation; RF input : 0 dBm @ 1 GHz
EARPHONE OUTPUT
2FSK Signal Analysis ASK/FSK Signal Demodulation & Analysis AM/FM Signal Demodulation & Analysis
Connector Type 3.5mm stereo jack, wired for mono operation
VIDEO OUTPUT
Connector Type DVI-I (integrated analog and digital), Single Link. Compatible with VGA or HDMI standard through adapter
RS-232C INTERFACE
Connector Type D-sub 9-pin female Tx , Rx , RTS , CTS
GPIB INTERFACE (OPTIONAL)
Connector Type IEEE-488 bus connector
AC POWER INPUT
Power Source AC 100 V ~ 240 V, 50/60 Hz Auto range selection
BATTERY PACK (OPTIONAL)
Battery Pack 6 cells, Li-Ion rechargeable, 3S2P With UN38.3 Certification
Voltage DC 10.8 V 2FSK FSK ASK FM AM
Capacity 5200 mAh/56Wh
GENERAL 2FSK modulation, for its features of low design cost and low electricity analysis measures parameters including ASK depth, frequency deviation,
Internal Data Storage 16 MB nominal consumption, is widely used by RF communications applications with low carrier power, carrier frequency offset, symbol, and waveform. Users can set
Power Consumption < 65 W
Warm-up Time < 30 minutes
power and low data transmission speed characteristics. Nowadays, 2FSK ASK depth, frequency deviation, carrier power and carrier offset for Pass/Fail
Temperature Range +5 °C ~ + 45 °C Operating modulation technology has been applied in various products and systems testing result. Data message is provided to determined preamble & sync
-20 °C ~ + 70 °C Storage
Dimensions & Weight 350(W) x 210(H) x 100(D) mm, Approx. 4.5kg Inc. all options (Basic + TG + GPIB + Battery) such as consumer electronics, automotive electronics, RFID, auto reading function.
13.8(W) x 8.3(H) x 3.9(D) inch, Approx. 9.9lb
electricity meter, and industrial control devices, etc. 2FSK signal analysis
TRACKING GENERATOR (OPTIONAL)
measures parameters including carrier power, FSK frequency deviation, AM/FM Signal Analysis measures parameters including AM depth,
Frequency Range 100 kHz ~ 3.25 GHz
Output Power -50 dBm ~ 0 dBm in 0.5 dB steps carrier frequency, and carrier frequency offset. Users can set the criterion frequency deviation, modulation rate, carrier power, carrier frequency offset
Absolute Accuracy ± 0.5 dB @160 MHz, -10 dBm, Source attenuation 10 dB, 20 ~ 30°C
Output Flatness
in frequency deviation and carrier offset for fast test result determination. and SINAD. Users can set the criterion in AM depth, frequency deviation,
Referenced ~ 160 MHz, -10 dBm
100 kHz ~ 2 GHz ± 1.5 dB carrier power and carrier offset for fast test result determination. The GSP-
2 GHz ~ 3.25 GHz ± 2 dB
Output Level Switching Uncertainty ± 0.8 dB Referenced to -10 dBm
RFID and optical communications systems often use Amplitude Shift Keying 9330 has a convenient AM/FM demodulation function to tune into AM or
Harmonics < -30 dBc Typical, output level = -10 dBm (ASK). Applications such as wireless telephone, paging systems, and RFID, FM broadcast signals and listen to the demodulated signals.
Reverse Power +30 dBm max.
ConnectorType N-type female etc. utilize Frequency Shift Keying (FSK). ASK/FSK demodulation and
Impedance 50 W Nominal
Output VSWR < 1.6:1 300 kHz ~ 3.25 GHz, source attenuation 12 dB
Note : The specifications apply when the GSP-9330 is powered on for at least 30 minutes to warm-up to a
B7 Good Will Instrument Co., Ltd. Simply Reliable temperature of 20 ℃ to 30 ℃, unless specified otherwise. Simply Reliable Good Will Instrument Co., Ltd. B8
3.25GHz Spectrum Analyzer

C. EMC PRETEST SOLUTION E. SIGNAL VERIFICATION, TEST AND ANALYSIS

Channel Power Measurement Spectrum Emission Mask CATV System Parameter Tests

ANT-04/ANT-05 PR-01 PR-02

GSP-9330 has the built-in EMI dedicated 200/9k/120k/1MHz filter, 20dB labs. GKT-008 can collocate with the Tracking Generator function of GSP- ACPR OCBW SEM CNR/CSO/CTB
low noise amplifier and Quasi-Peak/Average detection mode to conduct 9330 to conduct EMS tests.
Telecommunications and broadcasting service carriers SEM measures out-of-channel emission The built-in CNR/CSO/CTB functions of
radiation and conduction tests after collocating with the probe set.
For conduction tests, GSP-9330 can collocate with LISN and Isolation will encounter distorted signals caused by adjacent which is defined by corresponding in-channel GSP-9330 are ideal for measuring
GKT-008, the radiation test probe set, provides a complete near field test Transformer to conduct electromagnetic conduction tests. If users concern channels' inter-modulation while transmitting power. Users can set main channel's performance of CATV amplifier and system.
probe set to simplify the complex measurement procedures and to simulate EUT's large voltage variation or complexity, applying a Transient Limiter will modulated signals using communications channels. parameters, out-of-channel range, and limit
GSP-9330

GSP-9330
3m/10m far field tests from the labs. Using GKT-008 can greatly save make test equipment safer. If the distorted signals are too large the line, etc.
engineers' debugging time and the money for going back and forth to the
communications quality of adjacent channels will be Note: General CATV is 75Ω. For GSP-9330,
affected. The ACPR measurement can examine the GSP-9330 has the built-in SEM settings of a 50 ~ 75 ohm adapter is needed.
EMC Pretest Instruments Provided by GW Instek Are as Follows : leakage status that is conducive to identifying 3 GPP, WLAN 802.11b/g/n, Wimax 802.16
interference source. and self-defined communications system.
GSP-9330 Spectrum Analyzer Built-in complete EMC pretest solution
SEM supports the Pass/Fail test function
SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
GKT-008 EMI Near Field Probe Set Provide probe set for near field signals, including The OCBW measurement can simultaneously display and lists frequency range for surpassing each
ANT-04/ANT-05 field sensor OCBW, channel power and PSD. OCBW's unit is out-of-channel limit. An alarm signal will be
PR-01 AC high voltage probe shown by percentage. A measurement area containing triggered if any measurement results that are
PR-02 Source contact probe bandwidth will be shown when OCBW is in use. not matched with SEM.
GLN-5040A LISN LISN required by EMI conduction tests and it meets CISPR16-1-2:2006 regulations

GIT-5060 Isolation Transformer Different mains have different current leakages that will cause systems to have short circuit TOI (Third Order Intercept) Harmonic Time Domain Power
Isolation transformer prevents short circuit by isolating current loop

GPL-5010 Transient Limiter Transient Limiter will make test equipment safer if EUT has large voltage variation or complexity
For more detailed information about EMC Pretest Solution, please visit "DETAILED EMC PRETEST SOULTION" documents.

D. GRAPHIC PROCESSING OF SIGNAL MONITORING

Observe FM Signals by Spectrogram Observe WiFi Signals by Topographic Observe 4G LTE Signals by Split-Window Display Users can measure the linearity of non-linear Harmonic can easily measure the amplitude Users can go to zero span setting and open
systems and components such as receiver, of fundamental frequency and as high as ten marker to observe burst signals when
low-noise amplifier and mixer by TOI which orders of harmonic frequency. This function measuring burst signal in time domain is
automatically tests effective carrier and can also measure amplitude(dBc) which is required.
measures inter-modulation sidebands. the ratio of harmonic and corresponding
fundamental carrier. Total harmonic distortion
(THD)can also be calculated by this function.
The best harmonic information can be
obtained by adjusting RBW.

Spectrogram can simultaneously display power, frequency, and time. process of signal variation according to time changes that is beneficial Phase Jitter Marker Noise Gated Sweep
Frequency and power variation according to time changes can also be to observe intermittent feeble signals or electromagnetic interference
tracked. Especially, the intermittently appeared signals can be identified. signals. Users can use two makers to find out the relation of power to The Phase Jitter function can rapidly measure phase The marker noise function calculates the Radar or TDMA communications systems,
Users, by using Spectrogram, can analyze the stability of signal versus frequency and percentage. noise produced by RF signal source's and oscillator's average noise level over a bandwidth of via intermittently turning On/Off output
time or identify the intermittently appeared interference signals in the carrier deviation. This function can directly convert 1Hz, referenced from the marker position. power, control transmission signals. In
Split-Window allows two independent observations that are very order to monitor the power spectrum during
communications system. Users can use two markers to find out the signal jitter to phase (rad) and time (ns).
convenient for monitoring two different frequency bandwidths. the transmission process, the Gated Sweep
relation of power to frequency and time.
function can initiate measurement only
when signals appear. This function is ideal
Topographic uses color shade to show the probability distribution of
for measuring burst signals such as GSM
signal appearance. This function allows users to directly understand the or WLAN.

B9 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B10
3.25GHz Spectrum Analyzer

F. PRODUCTION LINE APPLICATIONS I. SOFTWARE SUPPORT

Sequence Function Limit Line Function PC Software - SpectrumShot

The sequence function allows users to edit a sequence formulated by a The limit line function, based upon the preset criteria of passing the test, Users can use the external software Spectrum Shot for EMI pretest report Under Get Trace mode, users can record the waveform data for long
series of steps directly from the instrument. Pause and delay can be can be used to directly determine whether the DUT passes the test. Test management and assessment, remote control and waveform data periods of time. It can be applied to spectrum monitoring for detecting
inserted in the sequence to observe the test results. There are five sets result not only can be shown on the LCD screen, but also an alarm recording for long periods of time. any abnormal radio signals. The software will send out e-mail to inform
GSP-9330

GSP-9330
of sequence for selection. Each sequence allows editing of 20 steps. signal output indication from the rear panel which is done by connecting users if any abnormal situation occurs.
Different sequence can be interactive and support each other. This a speaker or light device to show the test result. Under the EMI Pre-test Mode, users can select the required CISPR EMI
regulation for conduction and radiation measurement. Under the Remote Control mode, users can monitor wireless interference
function provides automatic editing without using the PC that is very
signals or observe signals for long periods of time.
convenient for assembly lines in which execute routine test procedures.

Shorten Warm-Up Time Wake-Up Clock IVI Driver & LabVIEW Support

IVI Driver Supports LabView & LabWindows/CVI Programming.


GSP-9330 utilizes the patented design of high efficient heat dissipation Users can set up automatic wake-up time for each day of the week. By
SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
It is available on NI website.
and feedback temperature control. After the instrument is turned on, the so doing, the purpose of GSP-9330 pre wake-up can be achieved. Pre
internal instrument can rapidly maintain a stable temperature so as to wake-up is ideal for the lower temperature environment to conduct
provide accurate amplitude measurement and deliver the frequency tests in the preset time.
measurement with 0.025 ppm frequency stability. J. VARIOUS AUGMENTING OPTIONS

Tracking Generator Scalar Network Analysis P1dB Point Measurement


G. USER FRIENDLY DESIGN

Status Icons Definition Help

3dB frequency bandwidth Reflection loss


Status Icons show the interface status, power status, alarm status and The built-in Definition Help function allows users to immediately
etc of GSP-9330. Users can easily understand the setting status and understand the parameters of Channel Power, OCBW, ACPR, SEM, TG option provides 0 to -50 dBm synchronized sweep output, conducts All active components have linear dynamic range for power output.
test results of the instrument. Phase Jitter, N-dB Bandwidth & P1dB items so as to save time on scalar network analysis (S11. S21) function as well as P1dB. Once output power reaches the maximum level, active component
reading user manual. will enter the non-linear saturated area of P1dB point and cease
The built-in tracking generator can swiftly and easily measure frequency amplifying signal intensity as well as produce harmonic distortion.
response of cable loss, filter bandwidth, amplifier gain, mixer conversion It is very useful for P1dB point measurement in active components
loss, etc. The N-dB Bandwidth function measures 3dB bandwidth of such as low noise amplifier, mixer and active filter.
H. COMMUNICATIONS INTERFACE Bandpass filter. SWR bridge should be connected with tracking generator
to measure the return loss of antenna or filter.
Various Interface File Storage and Video Output Battery Pack & Soft Carrying Case

DVI Interface USB Device/MicroSD

Provide USB Host, RS-232, LXI C(LAN), and GPIB(option) instrument Provide USB Device, MicroSD interface for file storage. Quick Save Compact and light-weighted(4 kg) GSP-9330 can be powered by battery Optional soft carrying case(GSC-009) provides convenience and
control interface. Supported programs comply with IEEE488.2. function is also available for users to quickly retrieve display. making it suitable for outdoor operations. Optional GSP-9330 battery pack protection to the instrument. GSP-9330 is equipped with 8.4 inches
Support DVI with 800 x 600 resolutions. (opt.02) has a battery life of two hours. 800 x 600 pixels LCD display which yields clearer display results for
outdoor operations.

B11 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B12
3GHz Spectrum Analyzer
Patent No. ZL201220347963.5
GSP-9300B is a 3GHz spectrum analyzer to meet basic RF measurement requirements. It provides the
frequency stability of 0.025ppm; the aging rate of 1ppm/year; a built-in preamplifier; the base noise of Rear Panel
-149dBm/Hz, and more than 20 measurement applications, including AM/FM modulation signal
analysis, signal channel analysis, and CATV parameter test. While collocating with TG option, GSP-9300B
can conduct frequency response or power linearity tests for components.

For monitoring signals, GSP-9300B provides Topographic display mode, which is capable of
distinguishing continuous or random signals by using color temperature. Spectrogram mode provides
a time axis on spectrum display that allows users to observe signal variations based upon the reference
of time. Split window mode allows different parameter settings for each display window. Additionally,
GSP-9300B also provides user-friendly user interfaces such as display mode, help, multi-languages, and
fast data logging, etc. Interfaces and software include USB/RS-232/LXI/MicroSD/GPIB (option)/DVI
GSP-9300B (9kHz~3GHz) output and dedicated PC software IVI Driver.
GRA-415 Rack Adapter Panel
LXI DVI GSP-9300B, with its unique features, including auto wake-Up, sequence function, and limit line testing, For : GSP-9300B, Rack Mounting (19", 6U)
is specially designed to meet the requirements of production lines. The patent design of heat conduction
Micro allows GSP-9300B to substantially reduce the warm-up time so as to expedite production processes.
GSP-9300B

GSP-9300B
SD/SDHC
Options include tracking generator, carrying bag, battery module, EMI antenna set and rack accessories.
The compact design of GSP-9300B satisfies either field testing or the integration of automatic testing
GSP-9300B
FEATURES systems.
* Frequency Range : 9kHz ~ 3 GHz SPECIFICATIONS
To sum up, GSP-9300B is a stable, light and all-purpose test equipment, which is the most ideal choice FREQUENCY
* 0.025ppm Frequency Stability and 1ppm
for the educational market, production line, and general signal monitoring applications, etc. Most FREQUENCY
Aging Rate Range 9 kHz ~ 3 GHz
SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
important, the pricing of GSP-9300B is beyond your imagination and it is the number one choice for Resolution 1 Hz
* Built-in Preamplifier, 50dB Attenuator, and
users with budget considerations. FREQUENCY REFERENCE
Sequence Function
Accuracy ±(period since last adjustment x aging rate)
* RBW : 1Hz ~ 1MHz Frequency Stability : 0.025ppm + stability over temperature + supply
voltage stability
* Sensitivity : -149dBm/Hz (@PreAmp on) ± 1 ppm max.
Wireless communications applications are nowadays ubiquitous. Signals in the limited spectrum are Aging Rate 1 year after last adjustment
* Built-in AM/FM Demodulation & Analysis
getting very crowded. Therefore, the demands of signal efficiency and frequency stability are higher and
Frequency Stability Over ± 0.025 ppm 0 ~ 50 °C GKT-001 General Kit Set
Temperature
* Built-in P1dB point, Harmonic, Channel Supply Voltage Stability ± 0.02 ppm Include :
stricter. To meet high precision measurement requirements, GSP-9300B provides the frequency stability ADP-002
Power, N-dB Bandwidth, OCBW, ACPR, FREQUENCY READOUT ACCURACY
of 0.025ppm and the aging rate of 1ppm/year, which only appear in high-end T&M equipment. ATN-100
SEM, TOI, CNR, CTB, CSO, Noise Marker, Start, Stop, Center, Marker ±(marker frequency indication x frequency
GTL-303
reference accuracy + 10% x RBW +
Frequency Counter, Time Domain Power, GSC-002
Built-in Preamplifier frequency resolution)
Trace Points Max. 601 points, Min. 6 points For: GSP-Series
Gated Sweep
Engineers often face the challenge of measuring small RF signals during product development stage. MARKER FREQUENCY COUNTER
* Built-in Spectrogram, Topographic and Dual-
GSP-9300B's built-in preamplifier provides the base noise of -149dBm. When collocating with the built-in Resolution 1 Hz, 10 Hz, 100 Hz, 1 kHz
View Display Modes
EMI filter and the dedicated EMI near field probe, GSP-9300B can conduct EMI tests and debugging. Accuracy ±(marker frequency indication X frequency RBW/Span >=0.02 ; Mkr level to GKT-002 CATV Kit Set
* Remote Control Software : SpectrumShot reference accuracy + counter resolution) DNL>30 dB Include :
* Remote Control Interface : LAN, USB, RS-232 More Than 20 Measurement Applications FREQUENCY SPAN ADP-001
Range ADP-101
* Options : Tracking Generator, GPIB 0 Hz (zero span), 100 Hz ~ 3 GHz
GSP-9300B provides rich signal processing functions, including AM/FM modulation signal analysis, Resolution 1 Hz GTL-304
Interface, Battery Pack signal channel analysis, and CATV parameter test, characteristic test on signal stability, and frequency Accuracy ± frequency resolution RBW : Auto GSC-003
PHASE NOISE For: GSP-Series
response or power linearity tests for components to substantially bring up the measurement convenience.
Offset from Carrier Fc=1GHz;RBW=1kHz,VBW=10Hz
Most competitors in the same class only offer a few test functions, and the standard built-in functions Average 40
of GSP-9300B are options for competitors. 10 kHz < -88 dBc/Hz Typical GKT-003 RLB Kit Set
100 kHz < -95 dBc/Hz Typical Include :
1 MHz < -113 dBc/Hz Typical
GAK-001
RESOLUTION BANDWIDTH (RBW) FILTER GAK-002
Filter Bandwidth 1 Hz ~ 1 MHz in 1-3-10 sequence -3dB bandwidth GTL-302
200 Hz, 9 kHz, 120 kHz, 1MHz -6dB bandwidth GSC-004
Accuracy ± 8%, RBW = 1MHz ; ± 5%, RBW<1MHz Nominal
Shape Factor
For: GSP-Series
<4.5 : 1 Normal Bandwidth ratio: -60dB:-3dB
VIDEO BANDWIDTH (VBW) FILTER
Filter Bandwidth 1 Hz ~ 1 MHz in 1-3-10 sequence -3dB bandwidth
GKT-008 EMI Probe Kit Set
Include :
ADP-002
GTL-303
GSC-009 Soft Carrying Case PR-01
PR-02
For: GSP-9300B ANT-04
ANT-05
For: GSP-Series

B13 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B14
3GHz Spectrum Analyzer
SPECIFICATIONS SPECIFICATIONS
AMPLITUDE REAR PANEL INPUT/OUTPUT
AMPLITUDE RANGE REFERENCE OUTPUT
Measurement Range 100 kHz ~ 1 MHz Displayed Average Noise Level(DANL)to 18 dBm Connector Type BNC female
1 MHz ~ 10 MHz Output Frequency 10 MHz Nominal
DANL to 21 dBm
Output Amplitude 3.3V CMOS
10 MHz ~ 3 GHz DANL to 30 dBm
Output Impedance 50
ATTENUATOR REFERENCE INPUT
Input Attenuator Range 0 ~ 50 dB, in 1 dB steps Auto or manual setup Connector Type BNC female
MAXIMUM SAFE INPUT LEVEL Input Reference Frequency 10 MHz
Input Amplitude -5 dBm ~ +10 dBm
Average Total Power +33 dBm Input attenuator 10 dB Frequency Lock Range Within ± 5 ppm of the input reference frequency
DC Voltage ± 50 V
ALARM OUTPUT
1 dB GAIN COMPRESSION Connector Type BNC female Open-collector
Total Power at 1st Mixer > 0 dBm Typical ; Fc 50 MHz; preamp. off TRIGGER INPUT/GATED SWEEP INPUT
Total Power at the Preamp > -22 dBm Typical ; Fc 50 MHz; preamp. on Connector Type BNC female
Mixer power level (dBm) = input power (dBm) attenuation (dB) Input Amplitude 3.3V CMOS
Switch Auto selection by function
DISPLAYED AVERAGE NOISE LEVEL (DANL) LAN TCP/IP INTERFACE
Preamp off 0 dB attenuation; RF Input is terminated with a 50W load. RBW 10 Hz; VBW 10 Hz; span 500 Hz; reference level = - 60 dBm; Connector Type RJ-45
trace average 40 Base 10Base-T; 100Base-Tx; Auto-MDIX
9 kHz~100 kHz < -93 dBm Nominal USB DEVICE
100 kHz~1 MHz < -90 dBm - 3 x (f/100 kHz) dB Nominal Connector Type B plug For remote control only; supports USB TMC
1 MHz~10 MHz < -122 dBm Nominal Protocol Version 2.0 Supports Full/High/Low speed
2.7 ~ 3.25 GHz < -116 dBm Nominal IF OUTPUT
GSP-9300B

GSP-9300B
Connector Type SMA female
Preamp on 0 dB attenuation; RF Input is terminated with a 50W load. RBW 10 Hz; VBW 10 Hz; span 500 Hz; reference level = - 60 dBm; Impedance 50 Nominal
trace average 40 IF Frequency 886 MHz Nominal
100 kHz~1 MHz < -108 dBm - 3 x (f/100 kHz) dB Nominal Output Level -25 dBm 10 dB attenuation; RF input : 0 dBm @ 1 GHz
1 MHz~10 MHz < -142 dBm Nominal EARPHONE OUTPUT
10 MHz~3.25 GHz < -142 dBm + 3 x (f/1 GHz) dB Nominal Connector Type 3.5mm stereo jack, wired for mono operation
LEVEL DISPLAY RANGE VIDEO OUTPUT
Log, Linear Connector Type DVI-I (integrated analog and digital), Single Link. Compatible with VGA or HDMI standard through adapter
Scales
Units dBm, dBmV, dBuV, V, W RS-232C INTERFACE
SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
Marker Level Readout 0.01 dB Log scale Connector Type D-sub 9-pin female Tx , Rx , RTS , CTS
0.01 % of reference level Linear scale
GPIB INTERFACE (OPTIONAL)
Level Display Modes Trace, Topographic, Spectrogram Single/Split Windows
Connector Type IEEE-488 bus connector
Number of Traces 4
Detector Positive-peak,negative-peak,sample,normal,RMS(not Video), AC POWER INPUT
Trace Functions Quasi-Peak(EMI),Average(EMI),Clear & Write,Max/Min Hold, Power Source AC 100 V ~ 240 V, 50/60 Hz Auto range selection
View, Blank, Average BATTERY PACK (OPTIONAL)
ABSOLUTE AMPLITUDE ACCURACY Battery Pack 6 cells, Li-Ion rechargeable, 3S2P With UN38.3 Certification
Absolute Point Center=160 MHz ; RBW 10 kHz; VBW 1 kHz; span 100 kHz; log scale; 1 dB/div; peak detector; 23°C±1°C; Signal at Reference Level Voltage DC 10.8 V
Capacity 5200 mAh/56Wh
Preamp Off ± 0.3 dB Ref level 0 dBm; 10 dB RF attenuation
Preamp On ± 0.4 dB Ref level 0 dBm; -30 dB RF attenuation GENERAL
FREQUENCY RESPONSE Internal Data Storage 16 MB nominal
Power Consumption < 65 W
Preamp Off Attenuation : 10 dB; Reference: 160 MHz; 20 ~ 30°C Warm-up Time < 30 minutes
100 kHz ~ 2.0 GHz ± 0.5 dB Temperature Range +5 °C ~ + 45 °C Operating
2GHz ~ 3 GHz ± 0.7 dB -20 °C ~ + 70 °C Storage
Preamp On Attenuation: 0 dB; Reference: 160 MHz; 20 ~ 30°C Dimensions & Weight 350(W) x 210(H) x 100(D) mm, Approx. 4.5kg Inc. all options (Basic + TG + GPIB + Battery)
1 MHz ~ 2 GHz ± 0.6 dB
2 GHz ~ 3 GHz 13.8(W) x 8.3(H) x 3.9(D) inch, Approx. 9.9lb
± 0.8 dB
ATTENUATION SWITCHING UNCERTAINTY TRACKING GENERATOR (OPTIONAL)
Attenuator Setting 0 ~ 50 dB in 1 dB step Frequency Range 100 kHz ~ 3 GHz
Uncertainty ± 0.25 dB Reference : 160 MHz, 10dB attenuation Output Power -50 dBm ~ 0 dBm in 0.5 dB steps
Connector Type N-type female 50 Nominal
RBW FILTER SWITCHING UNCERTAINTY Output VSWR < 1.6 : 1 300 kHz ~ 3 GHz, source attenuation 12 dB
1 Hz ~ 1 MHz ± 0.25 dB Reference : 10 kHz RBW
Note : The specifications apply when the GSP-9300B is powered on for at least 30 minutes to warm-up to a temperature of 20 ℃ to 30 ℃, unless specified otherwise.
LEVEL MEASUREMENT UNCERTAINTY
Overall Amplitude Accuracy ± 1.5 dB 20 ~ 30°C; frequency > 1 MHz; Signal input 0 ~ -50 dBm; ORDERING INFORMATION
Reference level 0 ~ -50 dBm; Input attenuation 10 dB;
RBW 1 kHz; VBW 1 kHz; after cal; Preamp Off GSP-9300B 3GHz Spectrum Analyzer
± 0.5 dB Typical
SPURIOUS RESPONSE ACCESSORIES :
Second Harmonic Intercept Preamp off; signal input -30dBm; 0 dB attenuation Power Cord, Certificate of Calibration, CD-ROM (with Quick Start Guide, User Manual, Programming Manual, SpectrumShot Software, SpectrumShot Guide & IVI Driver)
+35 dBm ; +60 dBm Typical; 10 MHz < fc < 775 MHz Typical; 775 MHz < fc < 1.625 GHz OPTION
Third-order Intercept Preamp off; signal input -30dBm; 0 dB attenuation
> 1dBm 300 MHz ~ 3 GHz Opt. 01 Tracking Generator
Input Related Spurious < -60 dBc Input signal level -30 dBm, Att. Mode, Att = 0dB; 20 ~ 30ºC Opt. 02 Battery Pack
Residual Response (Inherent) <-90 dBm Input terminated; 0 dB attenuation; Preamp off
Opt. 03 GPIB Interface
SWEEP
OPTIONAL ACCESSORIES
SWEEP TIME
GSC-009 Soft Carrying Case GKT-001 General Kit set GKT-008 EMI Probe Kit Set
Range 204 ms ~ 1000 s 50 s ~ 1000 s Span > 0 Hz Span = 0 Hz; Min resolution = 10 s
Sweep Mode Continuous; Single GRA-415 Rack Adapter Panel ADP-002: adaptor, SMA(J/F) ~ N(P/M) x 2 ADP-002 : Adaptor SMA(J/F)~N(P/M) x 1
ADP-001 ATN-100: 10dB attenuator, N(J/F) ~ N(P/M) x 1 GTL-303 : RF Cable SMA(P/M)~SMA(P/M) x 1
Trigger Source Free run; Video; External BNC to N-TYPE Adaptor GTL-303: RF cable assembly(SMA(P/M),RG316,600mm)x 2 PR-01 : AC Voltage Probe x 1
Trigger Slope Positive or negative edge ADP-002 SMA to N-TYPE Adaptor GSC-002: Kit box x 1 PR-02 : Touch Passive RF Probe x 1
RF PREAMPLIFIER GTL-246 USB Cable, USB 2.0, A-B Type, 1200mm GKT-002 CATV Kit set ANT-04 : H-field Probe x 1
Frequency Range 1 MHz ~ 3 GHz GTL-248 GPIB Cable, Double Shielded, 2000mm ADP-001: adaptor, BNC(J/F) ~ N(P/M) x 2 ANT-05 : H-field Probe x 1
Gain 18 dB Nominal (installed as standard) GTL-251 USB-GPIB Adapter, GPIB-USB-HS, USB 2.0, ADP-101: adaptor,BNC(J/F)75Ω~BNC(P/M)50Ω x 2
GTL-304: RF cable assembly(RG223,N(P/M)-N(J/F),300mm)x 2
FRONT PANEL INPUT/OUTPUT Hi-Speed USB compliance, 2000mm GSC-003: Kit box x 1
RF INPUT ATA-001 Antenna, General FM Antenna, BNC(M)
GKT-003 RLB Kit set
Connector Type N-type female
GTL-301 RF Cable, RG223 Assembly, 1000mm, N(P/M)
GAK-001: termination 50Ω, N(P/M) x 1
Impedance 50 Nominal GTL-302 RF Cable, RG223 Assembly, 300mm, N(P/M) GAK-002: Cap with chain, N(P/M) x 1
VSWR <1.6 :1 300 kHz ~ 3 GHz ; Input attenuator 10 dB GTL-303 RF Cable, RG316 Assembly, 600mm, SMA(P/M) GTL-302: RF cable assembly(RG223,N(P/M),300mm)x2
POWER FOR OPTION GTL-304 GSC-004: Kit box x 1
RF Cable, RG223 Assembly, 280mm, N(P/M) - N(J/F)
Connector Type SMB male FREE DOWNLOAD
Voltage/Current DC +7V/500 mA max With short-circuit protection
USB HOST SpectrumShot PC Software for Windows System (available on GW Instek website)
Connector Type A plug IVI Driver Supports LabVIEW/LabWindows/CVI Programming (available on NI website)
Protocol Version 2.0 Support Full/High/Low speed
MICRO SD SOCKET
Protocol SD 1.1
Support Cards Micro SD, Micro SDHC Up to 32GB capacity

B15 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B16
3GHz Spectrum Analyzer & RF and Communications Trainer
GSP-730 SPECIFICATIONS
FREQUENCY
Frequency Range Setting Range 150kHz ~ 3GHz
Center Frequency Setting Resolution 0.1MHz
Accuracy
Rear Panel
within ±50kHz
(frequency span : 0.3GHz ~ 2.6GHz, 20 ±5°C)
Frequency Span Setting range 1MHz ~ 3GHz
Accuracy within ±3%
(frequency span : 0.3GHz ~ 2.6GHz, 20 ±5°C)
Resolution Bandwidth Setting Range 30kHz, 100kHz, 300kHz,1MHz
SSB Phase Noise -85dBc/Hz (typical, 500kHz offset, RBW : 30kHz, Sweep time :
GSP-730 1.5s, Span : 1MHz@1GHz)
Inherent Spurious less than -45dBc@-40dBm Ref. Level (typical less than -50dBc)
3GHz Spectrum Analyzer
GSP-730 & GRF-1300/1300A

Response

GSP-730 & GRF-1300/1300A


AMPLITUDE
Reference Level Input Range +20 ~ -40dBm GSP-730
Accuracy Within ±2dB (1GHz) ; SPAN : 5MHz
Unit dBm, dBV, dBμV
Average Noise Level ≤ -100dBm (typical, center frequency : 1GHz RBW : 30kHz)
Frequency Within ±3.0dB@300MHz ~ 2.6GHz
Characteristic Within ±6.0dB@80 ~ 300MHz, 2.6 ~ 3GHz
Input Input Impedance 50
Input VSWR less than 2.0@input att 10dB
Input damage level +30dBm (CW average power), 25VDC
Input connector N connector
SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
SWEEP
GRF-1300/1300A Sweep Time Setting Range 300ms ~ 8.4s, auto (not adjustable)
Accuracy within ±2% (frequency span : full span)
RF and Communication Trainer GENERAL
Display 640 x 480 RGB color LCD GRF-1300 Front Panel GRF-1300A Front Panel
Communication RS-232C Sub-D female-D 9 pins
Interface USB Connector USB Host/Device full speed supported
VGA Output Sub-D female 15 pins
Power Source AC 100~240V, 50/60Hz
GSP-730 FEATURES OTHER
* Frequency Range : 150kHz ~ 3GHz Operating Temperature 5 ~ 45°C (Guaranteed at 25 ±5°C, without soft carrying case)
* Autoset Function Operating Humidity Less than 45°C / 90%RH ORDERING INFORMATION
* Noise level : <
_ -100dBm Storage Temperature -20 ~ 60°C, less than 60°C / 70%RH GSP-730 3GHz Spectrum Analyzer
* RBW Range : 30kHz, 100kHz, 300kHz, 1MHz DIMENSIONS &WEIGHT GRF-1300/1300A RF and Communication System Trainer
* ACPR/CHPW/OCBW Measurement 296(L) × 153(W) × 105(H) mm/11.6(L) x 6(W) x 4.1(H) in, Approx. 2.2kg/4.9lb ACCESSORIES :
* 3 Traces in Different Colors
GSP-730 : Quick start manual x 1, User manual CD x 1, Power cord x1
* Split Window Function GRF-1300/1300A SPECIFICATIONS GRF-1300/1300A : Experiment text book of student version, Power point file and remote control
* Limit Line Function GRF-1300A GRF-1300 software CD, GRF-1300 : RF cable x 3, Antenna x 1/
* Remote Control Software BASE BAND GRF-1300A : RF cable x 6, Antenna x 2, N to SMA adaptor connector x 1,
* Presentation Material for Training Courses Waveforms Sine, Square, Triangle Sine, Square, Triangle Power cord x 1
* Support Interface : USB Device/Host, RS-232C Frequency Range 0.1~3MHz , Step : 10kHz 0.1~3MHz , Step : 10kHz OPTION
* 5.6” TFT LCD with VGA Output Amplitude ≧1.5Vpp ≧1.5Vpp GBK-001 GRF-1300 Experiment text book of teacher version
≧0.75Vpp into 50 Ohm GBK-002 GRF-1300A Experiment text book of teacher version
Harmonic Distortion ≦-30dBc ≦-30dBc OPTIONAL ACCESSORIES
RF/FM ANALYSIS ADP-001 BNC to N-TYPE Adaptor
GRF-1300/1300A FEATURES
Frequency Accuracy ±0.15MHz ±0.15MHz ADP-002 SMA to N-TYPE Adaptor
* Waveform Support : ATA-001 Antenna, General FM Antenna, BNC(M)
Adjustable Range ≧45MHz (870M ~ 920MHz), ≧45MHz (870M ~ 920MHz),
Sine Wave : 0.1 ~ 3MHz Step : 1MHz Step : 1MHz GTL-303 RF Cable, RG316 Assembly, 600mm, SMA(P/M)
Square Wave : 0.1 ~ 3MHz Power Range ≧-15dBm ≧-15dBm GTL-246 USB Cable, USB 2.0, A-B Type, 1200mm
Triangle Wave : 0.1 ~ 3MHz FM FREE DOWNLOAD
* RF Frequency : 870 ~ 920MHz Max Frequency Deviation >3MHz >3MHz PC Software Training syetem remote control software
* AM Modulation & FM Modulation AM
* 5 On/Off Switches and 5 Test Points to Peak Difference ≧-18dBm ≧-18dBm
Simulate 8 Failure Conditions for Learning MIXER
Outcome Test LO + IF ≧-35dBm
* USB Interface to Provide Remote Control LO - IF ≧-35dBm
* Mixer & 2.4GHz Bandpass Filter MIXER + MODULATION
(Only GRF-1300A)
≧-60dBm
BANDPASS FILTER
Frequency Centre: 2.4GHz Bandwidth: ±20MHz
INTERFACE
USB Device USB Type B
DIMENSIONS & WEIGHT
165(W) x 155(H) x 90(D)mm/6.5(W) x 6.1(H) x 3.5(D)in, Approx. 1.2kg/2.6Ib
B17 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B18
3GHz Spectrum Analyzer
GW Instek GSP-730 is a 3GHz Spectrum Analyzer developed mainly to fulfill the demands of RF Communication educations. Budget A. AN ECONOMIC TURN-KEY SOLUTION
constraint and insufficient teaching tools are normally the two hurdles for schools to provide high-quality courses for RF communication
experiments. GSP-730, featuring full functions, a moderate spectrum analyzer should provide, along with GRF-1300/1300A RF
communication trainer possesses a unique position in the field as an economical turn-key solution for 3GHz RF Communication
Experiment courses.
GSP-730+GRF-1300 Solution
A TURN-KEY SOLUTION TO CLEAR AWAY TWO OBSTACLES
GSP-730, carrying 3GHz bandwidth and measurement functions including Autoset, Split Window, Limit Line, ACPR and OCBW etc., is
regarded as the advanced educations of Mobile Communications (GSM, 3G, 4G/LTE…), Wi-Fi, Zigbee and RFID in the Electronic or the
Communication classes. The USB ports, the RS-232 interface and the VGA video output facilitate the teaching efficiency. The combination
of GSP-730 and GRF-1300/1300A RF communication training is a turn-key system for both lecture and hands-on training purposes.
GSP-730 & GRF-1300/1300A

GSP-730 & GRF-1300/1300A


GRF-1300/1300A RF communication trainer, as the counterpart of GSP-730 for the basic RF communication experiment system, is capable
of generating a baseband signal and a RF carrier signal for the built-in AM and FM communication operations. The baseband signal output
contains the selections of Sine, Triangle, and Square waveforms in the frequency range of 100kHz ~ 3MHz, whereas the RF signal output
is a frequency-variable Sine wave in the range of 870 ~ 920 MHz. Connecting the baseband signal output with AM or FM inputs on the
panel, GRF-1300/1300A produces AM or FM signal output respectively by using the internal RF signal as the modulation carrier according
to users’ selected frequency.

The GRF-1300A RF training kit features not only all functions of GRF-1300 RF training kit but also augments itself with Mixer and Bandpass GSP-730+GRF-1300A+
Filter. Users can better understand the characteristics of Mixer and Bandpass Filter by operating scalar network analyzer measurement
which is produced by combining GSP-730 spectrum analyzer, GRF-1300A RF Communications Trainer, and USG signal generator. The USG-Series Solution
SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
combination of USG signal generator and GRF-1300A Mixer function can produce 2.4GHz AM and FM modulation signals. GRF-1300A
Bandpass Filter can purify the output signals by filtering out harmonic and spurious produced by Mixer output signals.

An Experiment Textbook (student's book) is available as the standard accessory of GRF-1300/1300A to provide experiment courses. The
curriculum of the textbook includes the introduction of the frequency domain and the time domain concepts, the operation theories of a
spectrum analyzer, and nine experiments to perform hands-on training for the learning of basic RF communication theories and the RF
measurement techniques using a spectrum analyzer. A CD, containing power-point slides for course presentation and the remote-control
software for experiment, is attainable with GRF-1300/1300A, allowing teachers to give lecture of experiment theories and perform
experiment simultaneously.

Another Experiment Textbook (teacher’s book) is accessible as an optional accessory of GRF-1300/1300A. In addition to the same contents
in the student’s book, this book provides the experiment results to the questions and as well as some advanced experiment theories. Thus,
a section of test-for-learning outcomes can also be seen in the lecturers' material in order to guide the students from the faulty diagnosis to
the correct one in a RF communication circuitry. On the GRF-1300/1300A panel, there are five test points set at different joints of circuit Fully-electronic RF Training System
blocks. Through turning on or off the corresponding relays of the five test points enables the teachers to simulate the faults and teach
students diagnosis technique.
In class, teachers can connect GSP-730 and GRF-1300 with a PC via Properly connect c Spectrum Analyzer, GRF-1300A RF and
The economical solution of GSP-730 and GRF-1300 greatly lowers the budget barriers for providing fundamental RF Communication USB or RS-232 interface. First of all, all the contents of experiment Communications Trainer, USG-LF44 RF Signal Generator and a PC
Educations and facilitates the establishment of RF communication experiment labs with more training stations in schools. has been converted into power-point slides and provided as the in- to perform ongoing experiments while the lecture is being given.
class materials. During lecturing the power-point slides, both Using a PC, teacher can present teaching material with Power Point
GSP-730 and GRF-1300 can be remotely set by GRF Training System slides and simultaneously control GSP-730, GRF-1300A and USG-
Introductions of Frequency Domain , Time Domain , and Spectrum Control Software. Moreover, the signal shown on GSP-730 can be LF44 to perform experiments and get spectrum displays parameter
Analyzer Basics. transferred to PC screen for further research. As a result, GSP-730 readings on the PC screen. GSP-730, GRF-1300A and USG-LF44
9 Experiments Include and GRF-1300 form an inclusive electronic-teaching-material easily transfer the current teaching materials including the
Operations of Spectrum Analyzer PowerPoint slides, textbook and the remote control software into
Base band and RF signal measurements package which efficiently simplifies lecturers' tasks before classes electronic-teaching system.
AM and FM signal measurements and shortens the process of the material preparation, and meanwhile,
Communication system and product measurements
enhances the quality of the lecture. If the PC can only offer one
Learning Outcome Tests USB interface, an extra purchase of USB hub* may solve the
Auxiliary Tools problem of insufficient USB interfaces. With proper installation,
PPT files including all experiments contents PC can manage the conjunction of GSP-730 and GRF-1300.
Remote control software to control GRF-1300, GSP-730 simultaneously
Experiment text books including the student version and the teacher(optional) * USB hub is excluded from the product standard accessories.

Test Points on GRF-1300 for Fault Diagnosis CURRICULUM CONTENTS

B19 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B20
3GHz Spectrum Analyzer
B. PC SOFTWARE FOR GSP-730 and GRF-1300 REMOTE CONTROL C. AUTOSET FUNCTION H. PASS/FAIL JUDGMENTS
GSP-730 & GRF-1300/1300A

GSP-730 & GRF-1300/1300A


This function may run the “Pass” and “Fail” inspection with “Pass” or “Fail” according to whether the input signal meets the
The dedicated PC software, Primary RF, is provided to support the The Autoset function automatically captures the signal and configures
efficiency. Firstly, a limit line or upper and lower limit lines should condition defined by the limit lines to indicate the examined
remote control of GSP-730 and GRF-1300 simultaneously. The control an appropriate setting for the optimum spectrum display at just one
be edited as the judgment criterion, then the LCD will display outcome.
includes base band signal waveform, frequency and RF signal press of the button. With the Autoset function, using a spectrum
frequency for GRF-1300 and Frequency, Span, Amplitude, RBW and analyzer like GSP-730 is no longer an annoying and complicated task.
spectrum transferring of GSP-730.
I. POWER MEASUREMENT FUNCTION

D. THREE-TRACE DISPLAY WITH THREE-COLOR IDENTITY E. MARKER FUNCTION


SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
ACPR OCBW

GSP-730 provides measurement functions such as ACPR, OCBW, will illustrate channels by various colors so that the operation may
GSP-730 can illustrate a signal with three colors simultaneously Five Markers can be used to obtain the measurement readings of and Channel Power. These items are regulated to be tested in become more precise and may minimize errors.
under various display modes, including Clear/Write, Max-Peak Hold, specified points. Each marker has a counterpart Marker, the
recent communication systems, such as CDMA system. GSP-730
Min-Peak Hold, View, Blank and Average. Other useful trace functions amplitude difference can be measured and indicated by setting the
frequency of marker and the interval frequency of Marker between
such as trace math operations are also accomplishable.
two signals. While several pairs of Markers are used for marking
more than one pair of signals at the same time, the Marker Table J. FLEXIBLE INTERFACE
can be turned on and it can process all the tests and demonstrate
the reading figures.
Flash Driver

F. SETTING STATUS PRESENTED BY ICONS G. SPLIT-WINDOW DISPLAY IN LIVE MODE


PC

Printer
GSP-730

The USB host interface on GSP-730 front panel allows the whatever demonstrated on the LCD display to other display
The intuitive icons help users grasp the current setting conditions all Under Split-Window Display Mode, the monitor will display two measuring diagrams to be saved in the memory stick. The USB device or projector, which will strengthen the impression while
the time. As all status icons are clearly shown at the corner of the independent screens, which can respectively have separated settings. Device and RS-232C interfaces on the rear panel are capable of giving the lectures.
screen, there is no need to worry about the unknown settings, which For instance, if processing the test between fundamental and connecting with a PC for remote control. VGA output can transfer
may cause confusion and lead to measurement errors. harmonic signals, the separated screens can respectively set at
different frequencies at the same time in order to process the
measurement.

B21 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B22
ACCESSORIES ACCESSORIES

RLB-001 ATA-001
Return Loss Bridge BNC Antenna
10MHz ~ 1GHz For: GSP-Series
For: GSP-Series (An additional ADP-001 is needed
for fitting GSP spectrum analyzers)

Frequency Range 10MHz ~ 1GHz


Directivity 10MHz ~ 100MHz : >48dB ; 100MHz ~ 1000MHz : >38dB
Insertion Loss Source to Load : <10dB ; Load to Coupler : <6dB
Return Loss Source Return Loss : >7dB ; Load Return Loss : >11dB
Coupler Return Loss : >17dB
Characteristic Impedance 50 Ohm
Connector N Type ; Source and Load : Female ; Coupler : Male
Dimension & Weight 88 x 54 x 32 (mm) , 230 g

GKT-008 EMI Probe Kit Set GKT-001 General Kit Set


ADP-002 : Adaptor SMA(J/F) ~ N (P/M) x 1 ADP-002
GTL-303 : RF Cable SMA(P/M) ~ SMA(P/M) x 1 ATN-100
PR-01 : AC Voltage Probe x 1 GTL-303
PR-02 : Touch Passive RF Probe x 1 GSC-002
ANT-04 : H-field Probe x 1 For:GSP-Series
ANT-05 : H-field Probe x 1
For: GSP-Series

GKT-002 CATV Kit Set GKT-003 RLB Kit Set


SPECTRUM ANALYZERS

SPECTRUM ANALYZERS
ADP-001 GAK-001
ADP-101 GAK-002
GTL-304 GTL-302
GSC-003 GSC-004
For:GSP-Series For:GSP-Series

ADP-001 ADP-002 GAK-001 GAK-002


Adaptor Adaptor Termination 50Ω Cap with Chain
BNC(J/F)~N(P/M) SMA(J/F)~N(P/M) N (P/M) N (P/M)
For:GSP-Series For:GSP-Series For:GSP-Series For:GSP-Series

GTL-248 GTL-250 GTL-251


ADB-002 ADB-006 ADB-008
DC Block BNC 50W 10MHz~2.2GHz DC Block N-TYPE 50W 10MHz~6GHz DC Block SMA 50W 0.1MHz~8GHz
For: GSP-9300B For: GSP-9300B For: GSP-9300B

GTL-246 GTL-110 GRA-415 Rack Adapter Kit


265
GAK-003 ADP-101 ATN-100
50Ω Impedance Adaptor BNC(J/F) 75Ω ~ 10dB Attenuator
For:GDS-Series, BNC(P/M) 50Ω N(J/F) ~ N(P/M)
GSP-Series For:GSP-Series
For:GSP-Series
482.6 (An additional ADP-001 is needed
97.7 for fitting GSP spectrum analyzers)

GLN-5040A GIT-5060 GPL-5010


GTL-301 GTL-302 GTL-303 GTL-304
RF Cable (RG 223 RF Cable Assembly RF Cable Assembly RF Cable Assembly
N(P/M) , (RG223, N(P/M), (SMA(P/M),RG316, (Rg223, N(P/M)
1000mm) 300mm) 600mm) ~N(J/F),280mm)
For:GSP-Series For:GSP-Series For: GSP-Series, For: GSP-Series
USG-Series
(An additional
ADP-002 is needed
for fitting GSP
spectrum analyzers)

B23 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. B24

Potrebbero piacerti anche