Sei sulla pagina 1di 52

MODULE 8

DIAGNOSTIC TOOLS

Overview 8-3
Objective 8-3
Purpose 8-3
Instructions 8-3
Introduction 8-4
Diagnostic Access 8-4
Diagnostic Options 8-5
Diagnostic Suites 8-6
Logs 8-8
Utilities 8-9
Transmitter Test (non NTHI) 8-11
Transmit Loopback Test (NTHI systems) 8-12
Video Test Patterns 8-14
Manual Diagnostics 8-15
Executing Tests using Manual Diagnostics 8-15
Continuous Tests 8-15
Logs 8-16
Hardware/Software Config 8-16
Interpreting Diagnostic Failures 8-17
Finding the Cause of Diagnostic Failures 8-17
Diagnosing AEGIS problems 8-17
Power On Diagnostics 8-18
Power-On Bypass 8-18
Power-On Diagnostic Configuration 8-18
Power-On Error Log 8-18
Troubleshooting Diagnostics 8-19
Diagnostic Questions 8-20
Diagnostic Test List 8-21
VPB FRU LIST 8-52
Module 8 - Diagnostic Tools Acuson Confidential

REVISION HISTORY

QRC P/N-REVISION INITIATOR APPROVAL DATE CHANGE

59163 Rev. X3 J. Koeper S. Williams 7/16/99 Incorporate reviewer comments


Beta

A3174 59163 Rev. 1 J. Madarasz S. Williams Dec. 2000 Initial Release

Module 8-2 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Overview

OVERVIEW
OBJECTIVE Be able to run hardware diagnostics on an Aspen™ Ultrasound
system including verification suites and individual tests.

PURPOSE It is important to understand how to run diagnostics to verify


system functionality and to help diagnose a failing FRU when a
system problem is apparent.

INSTRUCTIONS 1 Access the service diagnostics. The instructor will provide an access
number and password.
2 View and CLEAR the power on and system diagnostic logs.
3 Execute the keyboard test.
4 Execute the power supply test. Understand what it is displaying.
5 View the SMPTE test pattern.
6 Start the System Verification suite from the Manufacturing menu
and then cancel out of it.
7 Run the transmitter test.
8 Go to manual diagnostics and run the Z command.
9 In manual diagnostics:
• type H <RETURN> to view the help menu
• select the S & H commands to see the help menu all the options
available
• type S <RETURN> to see a list of board tests.
10 Enable and run the SVC board suite and then cancel out of it.
11 Run the individual DCI tests 6C4 and 6E8. Understand what they
are testing. The instructor will provide a scratch MO.
12 Enable and run the NI suite continuously. (Make sure to tell the
system not to stop on errors or fail too many times in a continuous
loop.) Cancel out of this test when necessary to move on to the next
module.

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 3


Module 8 - Diagnostic Tools Acuson Confidential

INTRODUCTION
Diagnostics are built into the system software and are available
through a menu-driven user interface. The system contains power-
on diagnostics, diagnostics available to the customer and
diagnostics for Service. The diagnostics used by Service are
proprietary to Acuson and controlled by an access number and
password.
DIAGNOSTIC ACCESS 1 First, go to the CUSTOMER LEVEL of diagnostics.
• Hold the TEST button immediately after power on, or press
RESET, then hold TEST.
• RESET is the button closest to the trackball under the right
handle. The TEST button is just to the right of it.
• Wait for 5 seconds until the menu appears. If power on
diagnostics begin, press RESET-TEST again.
2 Request access to the Service diagnostics.
• Highlight CONFIGURATION in the Customer Menu using the
trackball, then highlight and click on SERVICE ACCESS. See
Figure 1.

Figure 8-1 Customer Menu: Configuration


3 Input your ACCESS NUMBER at the prompt and press RETURN. The
access number format is: a12345 (Acuson employees) or b12345
(biomeds). Replace the 12345 with your employee number or
system serial number (for biomeds). If the number is less than five
digits, include enough leading zeros to follow the access number
format, for example a00123.

Module 8-4 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Introduction

4 Input the PASSWORD for the current month. Contact the Helpdesk if
you are not receiving your passwords via e-mail.
Entering your Acuson access number and password gives you
access to the Manufacturing Menu of Diagnostics.

NOTE: Once you enter the diagnostic password, for the next hour, you will
automatically access the Service diagnostics when you press Reset
Test.

DIAGNOSTIC There are two main options for running diagnostics once you are at
OPTIONS the Manufacturing Menu: Suites and Manual Diagnostics.

Diagnostic suites System Verification, All Noninteractive, 2-D, Color, AEGIS® Digital
Image and Data Management system, M-mode, Pulse Doppler, Scan
Converter Control, Video, and UI.
The diagnostic suites help choose which tests to run for a specific
problem. These suites were designed by Diagnostic Engineering to
test the major hardware that is involved with the different
modalities. You will not get any information about test failures until
the entire suite is complete.
Manual Similar to XP® Ultrasound system diagnostics using a command
diagnostics line interface. Tests can be custom configured by suite or by
individual test, and can be run once, or continuously. Manual
diagnostics provide pass/fail information as the tests are being run.

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 5


Module 8 - Diagnostic Tools Acuson Confidential

DIAGNOSTIC SUITES

Figure 8-2 Manufacturing Menu with Diagnostic Suites


1 Highlight the suite desired and click the trackball select key to start
the suite.
2 Results will display when the test is complete. See approximate
completion times in the table below.
• CODE-C will exit a test or diagnostic suite.
• While the tests are running the screen is blank except for the test
number. No pass/fail information is displayed until the suite is
complete.
• After the test is complete, any failures are displayed on the
system screen and also recorded in the system diagnostic log.
Table 8-3 Diagnostic Suite Descriptions

DIAGNOSTIC SUITE DESCRIPTION APPROX.


TIME

System Verification Designed to verify the system’s 30 minutes


(PM) performance.

All non interactive The complete set of non-interactive 1 hour, 15


(NI) diagnostics, equivalent to what is run in minutes
the factory during production testing.

2-D Imaging (2-D) 2-D imaging hardware: AQP, CDM, RP, 30 minutes
SVC, VPB, DCC, ZDT, IOB, SCP4, PPS,
UIC, MEX, ZDL and ZIP.

Color Doppler Color Doppler hardware: FEC, FEB and 10 minutes


(CD) CRP.

Internal AEGIS AEGIS hardware: DCI and JPEG. 15 minutes


(AEGIS)

M-mode (CARD) M-mode hardware: WFP 5 minutes

Pulse Doppler (PD) Pulse Doppler hardware: DAQ, DSP and 5 minutes
WFP

Module 8-6 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Suites

DIAGNOSTIC SUITE DESCRIPTION APPROX.


TIME

Scan Converter Scan Converter Control hardware: RP, 15 minutes


Control AQP, and CDM
(SCC)

Video (VID) Video hardware: VPB 20 minutes

User Interface (UI) Non-interactive test of keyboard and UI. 5 minutes

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 7


Module 8 - Diagnostic Tools Acuson Confidential

LOGS
Table 8-4 Log Descriptions

LOG DESCRIPTION

Power On Log Stores power on errors encountered until log is cleared.

System Diagnostic Stores any errors found by running diagnostic suites or


Log manual diagnostics.

Current Keystroke Displays Current Keystroke Log from Engineering


Log Menu. Displays the most recent user keystrokes.

Error Keystroke Displays Error Keystroke Log from Engineering Menu.


Log Displays the user keystrokes immediately prior to the
newest message in the Error Message Log.

Error Message Log Displays Error Message Log from Engineering Menu.
View this log to check for intermittent problems that
may occur between site visits.

While viewing a log, use the trackball to highlight and click on one
of the available options:
• CLEAR LOG: erases data in the power on or diagnostic log.
• DUMP LOG: to send the data in the log out of the serial port J20 at
a baud rate of 9600.
• EXIT: to return to the diagnostic menu.
• NEXT: to view the next page of the log.

Module 8-8 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Utilities

UTILITIES
Table 8-5 Utility Descriptions

UTILITY DESCRIPTION

Keyboard Allows keyboard verification with interaction. This is the same


Functionality as the utility given in the Customer Menu.

Power Supply Displays average and peak voltages for the power supplies.
Measurement

Store BBM Stores BBM settings to a file on a laptop via the serial port.

Restore BBM Restores BBM settings from a file on your laptop via the serial
port. Described in Section 9.4.

System Noise Not yet available. Measures the noise floor of the Scanner
receive chain using a custom DL board.

Transmitter Verifies gross transmitter functionality. See Section 4.2 on


transmitter test for full instructions.

Memex Verifies Memex checksum - use after upgrade. Can also be


checksum invoked from Manual Diagnostics, test 7F8.

Lock system Disables repeat diagnostic access to the Manufacturing Menu


without a password. Without selecting lock system, a user
automatically gains access to the Manufacturing Menu for one
hour after entering a valid password.

Clear all BBM Caution! This will clear all Battery-Backed Memory in the
system. Does not affect AEGIS system exams. Read the section
on Clearing BBM to find all the steps to recover.

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 9


Module 8 - Diagnostic Tools Acuson Confidential

Figure 8-3 Keyboard Functionality Test

Figure 8-4 Power Supply Measurement

NOTE: • Scanner +50V -120V are not used in the system and should be 0.0
volts.
• System 120VAC measurement display is usually 10VAC to 12VAC
^low. Measure the system line voltage at the wall outlet or power
supply (MDI) to obtain an accurate measurement.

Module 8-10 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Utilities

TRANSMITTER TEST The transmitter test under utilities allows testing of all transmit
(NON NTHI) channels in the system. This test is used on Aspen system instead of
the Transmit Chain test used on XP systems.
1 Connect a DLX2 board to one of the DL ports on the front of the
system using the DL adapter. Use any transducer ID.
2 Select the TRANSMITTER TEST under UTILITIES from the
Manufacturing Menu.
The test describes exactly how to set up the scope and DLX2 board.
The procedure is listed below for reference.
3 Enter 1 to select DL1 (left), 2 to select DL2 (right)
4 Enter number of transducer thermistors (0 to 2)
Enter 2 to test both of the thermistors.
5 After selecting 2 thermistors, do the following:
Set the DLX2 toggle switches as follows:
6 Upper set (CH 1N) to OPEN and CAL1
7 Lower set (CH 1P) to OPEN and CAL1
8 Press any key to continue when the switches are set properly.
9 Turn the oscilloscope on and connect it to the DLX2 with a BNC.
Disconnect the 50 ohm BNC terminator, if present.
10 Set up the oscilloscope as follows:
• Vertical sensitivity: 0.5 volts/div
• Horizontal sweep speed: 2 ms/div (5ms preferred)
• Trigger source: <channel connected to DLX2 BNC>
• Trigger level: -2 volts to -7 volts

NOTE: Ignore the values on the Aspen screen; use the following values.

11 Type 0 to start the transmit/receive starting line number at 0.


12 Check for the following signal to confirm that the transmit channel
is good.

Figure 8-5 Transmit channel pulse


13 Press the period key, “.”, on the keyboard to advance the transmit
channels one by one.
14 Test the other DL port using the same procedure.

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 11


Module 8 - Diagnostic Tools Acuson Confidential

TRANSMIT
LOOPBACK TEST
(NTHI SYSTEMS)
Requirements In order to run this diagnostic successfully you will need the
following:
• an Aspen system
• 3.5 or higher software. Note that the test has even better error
reporting at Aspen 4.0 and higher
• NTHI hardware (including XMT5, XDY4, IFD2 boards)
• L7, V4, or 4V2c transducer (or DLX card simulating one of these
transducers.)
◆ To run the transmit loopback test (NTHI systems)
1 Turn on the system and go to Manual Diagnostics.
2 Plug in an L7, V4, or 4V2c transducer (or DLX card simulating one
of the following: L7 - 10100101, V4 - 10000111.)
3 Execute diagnostic test 4A3.
4 Read the troubleshooting section if you have any failures.
Theory of This test verifies the boards involved in the transmit chain (XMT,
Operation XDY) as well as the transducer and ZDL.
The test fires many short ultrasound lines with only 1 transmit
channel turned on during each line fire. Several sets of pulses are
fired on each channel with different apodization levels. The pulses
are fed back into a receive channel by the ZDL and travel from: RCV
> SDL > DBL > IFD > VDT > DBL and then to the Scan Converter
IOB > AQP > SVC.
This test verifies transmit channels 1 to 126 if using an L7 or V4. If
using a 4V2, channels 0-15 and 112-127 do not get tested due to
physical limitations of the transducer. The test also uses Receiver
channels 0 and 127 to pass the information. Note that if there is a
problem on either of these receiver channels, the test will fail for
half of the transmit channels.
Troubleshooting This is a new test and is still being optimized. If there is a failure,
analyze the data. If the channel is just barely out of tolerance, it may
be acceptable.
“System too If the test sees too much variation ( > 25%) in the baseline signal
Noisy” Failures amplitude, it gives the error message “system too noisy” and fails.
Failures like this are caused by FRUs which affect ALL 128 channels
in the system, including: VDT, IFD, IGD, DBL, ZDL, AQP, IOB, RP,
SVC, cables. It may be helpful to run additional diagnostics.

Module 8-12 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Utilities

Individual Channel If an individual channel (or several channels) fail, the test reports
Failures the channel number along with the measurement for that channel. It
also reports the upper and lower limits for the area it expected to
get for that case of pulse count and apodization. The tricky part of
troubleshooting individual channel failures is that you don’t know
which board in the system is causing that failure. It could be a
transducer, XMT, RCV, SDL, ZDL, XDY, MXK, or APD. Remember
that the RCVs and SDLs are only using and testing channels 0 and
127.
• To determine if a transducer is causing the failure, use a
different transducer or test using a DLX2.
• Swap boards and locations to try to determine if a PCB is
causing the problem. Take careful notes while you move boards
around in the system.

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 13


Module 8 - Diagnostic Tools Acuson Confidential

VIDEO TEST PATTERNS


The following video test patterns are available to both the Customer
and Service.
Table 8-5 Video Test Pattern Descriptions

TEST PATTERN DESCRIPTION

SMPTE EG 1-1990 Used to calibrate accessory monitors and color


Color Bar Test peripherals.
Pattern

SMPTE RP 133-1986 Used to calibrate B/W printers.


Medical Diag Pattern

Crosshatch Pattern Used to evaluate monitor geometry and convergence.

100% WHITE Flat Recommended for locating any missing GBR triplets
Field on the monitor.

100% GREEN Flat Recommended for locating any missing green pixels
Field from monitor.

100% BLUE Flat Field Recommended for locating any missing blue pixels
from monitor.

100% RED Flat Field Recommended for locating any missing red pixels
from monitor.

GBR Crosshatch Recommended for easier evaluation of monitor


convergence.

100% Window Recommended for QV100 Pendant Calibration.


Pattern

Others... As desired.

Module 8-14 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Manual Diagnostics

MANUAL DIAGNOSTICS
EXECUTING TESTS The operation in manual diagnostics mode is similar to diagnostics
USING MANUAL on the XP system. There are selections to run individual tests,
DIAGNOSTICS enable board suites, and run tests continuously.
1 Highlight and select MANUAL DIAGNOSTICS from the Manufacturing
Menu in Diagnostics.
2 Type H followed by [RETURN] for help and S to show the test suites.
See Appendix A and B for printouts of these commands.
3 Run tests as desired. For example:
• Suites: type the abbreviated suite name followed by [RETURN]
to begin the tests. e.g., NI [RETURN] will run the All non-
interactive suite.
• Board tests: type BE (board test number) [RETURN] to enable
the board tests, then type R to run the tests, e.g., BE2 [RETURN],
R [RETURN] will enable and run all tests for the CRP board.
• Individual tests: type X (test number) [RETURN], e.g., type X7F8
[RETURN] to run the MEMEX checksum test.
4 Type STAT [RETURN] to display any failures that occurred while
running a diagnostic suite.

NOTE: Contents of STAT will be lost on power off. Failures in Manual


Diagnostics are also stored in the system diagnostic log.

5 Type STAT! [RETURN] to display all tests run regardless of failures or


not.
6 Press CODE-C to exit from a test or diagnostic suite.
CONTINUOUS TESTS Enable a test suite and run it continuously to help find intermittent
problems.
1 Type STATCLEAR [RETURN] to clear any diagnostic failures in
memory.
2 Type FLIMIT=2 [RETURN] to limit the failures on any given test to 2.
3 Type SOE=OFF [RETURN] if you do not want the diagnostics to stop
when an error is found.
4 Enable the test suite or board suite you desire.
• Suites: type E=(suite) [RETURN] to enable the desired suite. Type
O=(suite) [RETURN] to disable any suites you don’t want to run.
e.g., E=NI [RETURN] will enable the All non interactive suite;
O=AEGIS [RETURN] will remove the AEGIS suite from the tests
to be run.
• Board tests: type BE (board test number) [RETURN] to enable
the board tests. e.g., BE2 [RETURN], will enable all tests for the
CRP board.
• Individual tests: type A (test number) [RETURN] to enable
specific tests. e.g., type A7F8 [RETURN] to enable the MEMEX
checksum test.

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 15


Module 8 - Diagnostic Tools Acuson Confidential

5 Type C [RETURN] to run the tests continuously.


6 The test suite will not stop until you press CODE-C to cancel.
7 Type STAT [RETURN] to display any failures that occurred while
running a diagnostic suite.

NOTE: Contents of STAT will be lost on power off, but are stored in the system
diagnostic log.

LOGS The SYSCON and diagnostic logs available from the Manufacturing
Menu of Diagnostics as described in Section 2.0 are also available in
Manual Diagnostics. See Appendix A for the commands to view
these logs, e.g. type SHOW SYSLOG [RETURN] to view the system
diagnostic log.
HARDWARE/ Diagnostics provides a way to verify the software in the system. It
SOFTWARE CONFIG allows verification of the bootproms installed on specific boards in
the Aspen system. This information is NOT included in the Version
Report of the Engineering Menu. Use this command after upgrades
to verify all bootproms in the system are the correct version.
• Type Z [RETURN] to display a hardware and software config of
the system. See Appendix C for an example printout using this
command.

Module 8-16 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Interpreting Diagnostic Failures

INTERPRETING DIAGNOSTIC FAILURES


If a diagnostic failure is encountered during a test suite, always
proceed to manual diagnostics (as described in the next section) and
run the test again. This will serve two purposes:
• Manual diagnostics will give you more information about the
test and the failure. Running the test in the suite will only give
you pass/fail information.
• Some tests may fail in the diagnostic suites due to dependencies
and are not true hardware failures. If a diagnostic test fails
when run from a test suite, run the failing test again from
Manual Diagnostics. If it then passes, ignore the original failure
from the test suite. Always assume a diagnostic failure is real
unless 1) Manual diagnostics proves otherwise, or 2) the failing
test is shown in a known false failure list for that Aspen release,
or 3) you’ve verified with the STAT or FSE that it is a known
false failure.
FINDING THE CAUSE 1 Verify that the failure is not a known diagnostic failure.
OF DIAGNOSTIC 2 Check Appendix D of this document for possible FRU causing the
FAILURES problem.
3 Call the STAT center for more troubleshooting information
regarding the diagnostic failure.
DIAGNOSING AEGIS 1 Always run the AEGIS suite of diagnostics if the customer
PROBLEMS complains of lockups while using AEGIS or if AEGIS will not
respond at power on. The diagnostics will usually find any
problems with hardware.
2 If all AEGIS diagnostics pass, then software corruption is suspected.
The AEGIS software should be reinstalled on the hard drive.

NOTE: Do NOT swap the hard drive until after running diagnostics and
reloading software. Very rarely are problems related to a hardware
failure of the hard disk.

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 17


Module 8 - Diagnostic Tools Acuson Confidential

POWER ON DIAGNOSTICS
A five minute set of diagnostics run once per day, the first time the
system is powered up. On subsequent power ons or resets,
diagnostics will run again or can be set to be bypassed until the next
calendar day. Power on errors are stored in a power on log
described in Section 6.3
POWER-ON BYPASS The Aspen system has a diagnostic bypass for EMERGENCY USE
by customers. Press the SPACE BAR at any time during the power-
on diagnostics to go to system imaging. The bypass may be used for
system troubleshooting and should not cause any system problems.

NOTE: The diagnostic bypass is for EMERGENCY USE only by customers. In


normal operation customers should allow power-on diagnostics to run
each day on start up.

POWER-ON Power-on diagnostics are set to run once per day as the factory
DIAGNOSTIC default. This can be changed by the customer so that power on
CONFIGURATION diagnostics run every time the system is powered on.
1 Use the trackball to highlight CONFIGURATION in the Service or
Customer Diagnostics and the current power on selection will be
displayed (ONCE-PER-DAY or EVERYTIME.)
POWER-ON ERROR Any power-on diagnostic errors are displayed on the screen after
LOG power-on diagnostics complete, and are also stored in the power-on
diagnostic log. This is found under LOGS in the Customer or Service
diagnostic menus.

Module 8-18 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Troubleshooting Diagnostics

TROUBLESHOOTING DIAGNOSTICS
Table 8-2 Troubleshooting Diagnostics

PROBLEM SOLUTION

1 Diagnostic “Password Type in access number. At password


Disabled” prompt type LOCK RETURN. The system
displays an 8 digit number. Call STAT or
an FSE and request a “key” for the lock
displayed on the system. Do not reset or
the lock will change.

2 Diagnostic “Password Verify that the access number and


Invalid” password are entered correctly. Check for
any values that could be mis-interpreted
as other numbers or letters.
Check that the system date is set properly.

3 Diagnostic Failure Run the test in Manual Diagnostics if test


was previously run using a diagnostic
suite. This verifies the failure and provides
more information.
Call the Helpdesk for details on the failure
if needed. Some software levels may have
known failures that should be ignored.

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 19


Module 8 - Diagnostic Tools Acuson Confidential

DIAGNOSTIC QUESTIONS
1 Which diagnostic suite is the most thorough? ________

2 There is a section of the Scanner that is not verified by diagnostics,


but can be verified by a separate diagnostic tool. Please name the
section, FRUs and the tool used to verify it.

3 What command in manual diagnostics provides helpful software


information? _________

What information provided is NOT provided anywhere else?


____________________________

4 What commands are necessary to program the system to run the


DCI board suite in a continuous loop?

5 A RCV test failed during a PM suite. What are the next steps in
troubleshooting?

6 Which individual tests can be used to quickly verify if the AEGIS


system SCSI chain is functional?

Module 8-20 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

DIAGNOSTIC TEST LIST


The table below is a list of executable tests in the diagnostics
database. Next to each test is a list of external sources required for
the test and major FRUs which could be the cause of failures for
each test. The FRU list associated with each test failure is a small
indication of POSSIBLE FRUs. The list of FRUs are given left to
right in the order of highest probability of failure. Any FRUs with a
probability of having less than 10% being the cause of failure are not
included.

TES TEST DESCRIPTION FRUS


T

4D DAQ Cw Initialization Mode DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

4E DAQ Cw Normal Mode DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

4F DAQ ADC Gain Linearity test DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

50 DAQ Offset Calibration test DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

51 DAQ Cal On Non-Doppler Lines DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

52 DAQ Fifo Low Nibble test DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

53 DAQ Fifo Middle Nibble test DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

54 DAQ Fifo Hi Nibble test DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

55 DAQ Alpha Analog test DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

56 DAQ2/3 Rg Acc Digital test DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

57 DAQ2/3 Alpha Digital test DAQ, IOB, SVC, WFP, STG, FEC, scanner control
cable

58 DAQ External SOL test DAQ, STG, IOB, ZDT, scanner control cable

73 FEB Cine Ram Quick Addr test FEB

74 FEB Cine Ram Quick Data test FEB

9A FEC - SVC2 DPR Bak test FEC, SVC

9B FEC - SVC2 DPR Inc test FEC, SVC

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 21


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

9C FEC Dual Port Ram Bak test FEC

9D FEC Dual Port Ram Inc test FEC

9E FEC Up External Ram Bak test FEC

9F FEC Up External Ram Inc test FEC

A0 FEC Time Slice Ram Bak test FEC

A1 FEC Time Slice Ram Inc test FEC

A2 FEC Input Path test FEC, DAQ, ZDT, IOB, SCP

A3 FEC Range Gate Accumulator test FEC, DAQ, ZDT, IOB, SCP

A4 FEC Write Address Counter test FEC, DAQ, ZDT, IOB, SCP

A5 FEC Line Type/Number test FEC, ZDT, IOB, SCP

A6 FEC Output Path test FEC

A7 FEC High Pass Filter Addr 1 FEC

A8 FEC High Pass Filter Addr 2 FEC

A9 FEC X0 M.A.C. test FEC

AA FEC X1 M.A.C. test FEC

AB FEC M.P.Y. (A) test FEC

AC FEC M.P.Y. (B) test FEC

AD FEC Read Address Counter test FEC

AE FEB Cine Ram Bak test FEB

AF FEB Cine Ram Inc test FEB

B0 FEB Cine Ram Refresh test FEB

B1 FEB V Ram Bak test FEB

D8 FEC Code RAM Data Bus test FEC

D9 FEC Code RAM March-C test FEC

DA FEC Code RAM Data Bus test Utility N/A (utility tool)

DB FEC Code RAM March-C test Utility N/A (utility tool)

112 FEC Output Interleave test FEC

113 FEC Input Interleave test FEC, DAQ, ZDT, IOB, SCP

114 FEC Group Info Msg test FEC

115 FEC Overflow Check test FEC, DAQ, ZDT, IOB, SCP

Module 8-22 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

116 FEC - SVC2 DPR Arbitration FEC, SVC

118 DAQ Accumulator Full test - need external DAQ, SVC


voltage source

119 DAQ Accumulator Fd test - need external DAQ, SVC


voltage source

11A DAQ Sig Loop N/A (utility tool)

11B DAQ3 Ampl Thresh Loop N/A (utility tool)

11C DAQ ADC Display N/A (utility tool)

11D DAQ ADC Gain Linearity Adj N/A (utility tool)

11F FEC Input O-Scope Loop 1 N/A (utility tool)

120 FEC Input O-Scope Loop 2 N/A (utility tool)

121 FEC Output O-Scope Loop 1 N/A (utility tool)

122 FEC Output O-Scope Loop 2 N/A (utility tool)

123 FEC Prom Checksum N/A (utility tool)

125 FEC Signature Analysis N/A (utility tool)

126 FEB V Ram Inc test FEB

127 FEB Vet Ram Bak Tst FEB

128 FEB Vet Ram Inc Tst FEB

129 FEB Peak Map Ram Bak test FEB

12A FEB Peak Map Ram Inc test FEB

12B FEB Depth Gain Comp Ram Bak test FEB

12C FEB Depth Gain Comp Ram Inc test FEB

12- FEB Per R/W Address Ram Bak test FEB


D

12E FEB Per R/W Address Ram Inc test FEB

136 FEB Vel to CRP Xfer test CRP, FEB, FEC, SVC

137 FEB Var to CRP Xfer test CRP, FEB, FEC, SVC

138 FEB Energy to CRP Xfer test CRP, FEB, FEC, SVC

139 FEB Per. Eng Data Func test FEB

13A FEB Per. Eng ALU Func test FEB

13B FEB Per. Eng Const Sel Func test FEB

13C FEB Va/Th Compare test FEB

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 23


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

13D FEB Th/E Compare test FEB

13E FEB Ve/Th Compare test FEB

13F FEB Cine Read Eol Compare test FEB

140 FEB Per. R/W Eol Compare test FEB

141 FEB Status test FEB

143 FEB FEC to FEB Cine Ram Xfer Tst FEB, FEC

144 FEB FEC to FEB Xfer Enable test FEB, FEC

149 FEB Peak Detect test FEB

154 DSP TMS 320C10 Audio Test N/A (utility tool)

155 DSP Program Memory Bak Test DSP, SVC

156 DSP Program Memory Inc Test DSP, SVC

157 DSP Program Memory Address Test DSP, SVC

158 DSP Program Memory Data Test DSP, SVC

159 DSP Output Buffer Memory Bak Test DSP, SVC

15A DSP Output Buffer Memory Inc Test DSP, SVC

15B DSP Output Buffer Memory Address Test DSP, SVC

15C DSP Output Buffer Memory Data Test DSP, SVC

15D DSP TMS 320C10 Diagnostics DSP, SVC

163 DAQ Pv Lo-Nibble Memory Bak DAQ

164 DAQ Pv Lo-Nibble Memory Inc DAQ

165 DAQ Pv Lo-Nibble Memory Addr DAQ

166 DAQ Pv Lo-Nibble Memory Data DAQ

167 DAQ Pv Hi-Byte Memory Bak DAQ

168 DAQ Pv Hi-Byte Memory Inc DAQ

169 DAQ Pv Hi-Byte Memory Addr DAQ

16A DAQ Pv Hi-Byte Memory Data DAQ

16B DAQ Pd Memory Bak DAQ

16C DAQ Pd Memory Inc DAQ

16D DAQ Pd Memory Addr DAQ

16E DAQ Pd Memory Data DAQ

Module 8-24 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

171 FEB Fi/Sp test FEB, CRP

172 FEB Shifter/Normalizer test FEB

173 FEB Per Eng V Operations test FEB

174 FEB V to Vt Transfer test FEB

175 FEB Cine to Cine Transfer test FEB

1A3 SPT SCNR SDL Gain SDL, RCV, VDT, IFD, AQP, scanner analog cable,
DCC, MXK, MEX

1A4 SPT SCNR SDL Delay SDL,RCV,VDT,IFD,AQP, scanner analog cable,


DCC,MXK,MEX

1A5 SPT SCNR SNR (noise/gain) - need FTB scanner analog cable, IOB, ZDT, ZDL, APD, VDT,
IFD, DBL, RCV, power supplies, scanner
motherboard, AQP

1A8 SPT SCNR Thermal SDL Delay SDL, RCV, VDT, IFD, AQP, scanner analog cable,
DCC, MXK, MEX

200 WFP Dual Port RAM SVC Address WFP, SVC

201 WFP Dual Port RAM SVC Data WFP, SVC

202 WFP Code RAM WFP

203 WFP Video Clocks WFP

204 WFP Dual Port RAM WFP Address WFP, SVC

205 WFP Dual Port RAM WFP Data WFP, SVC

206 WFP Writes/SVC Reads Dual Port RAM WFP, SVC


Contention

207 SVC Writes/WFP Reads Dual Port RAM WFP, SVC


Contention

208 WFP Cine RAM CPU Address WFP

209 WFP Cine RAM CPU Data WFP

20A WFP Cine RAM CPU Exhaustive WFP

20B WFP Erase Bar RAM CPU Address WFP

20C WFP Erase Bar RAM CPU Data WFP

20D WFP Erase Bar RAM CPU Exhaustive WFP

20E WFP M Mode RAM CPU Address WFP

20F WFP M Mode RAM CPU Data WFP

210 WFP M Mode RAM CPU Exhaustive WFP

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 25


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

211 WFP M Mode Buffer Select WFP

212 WFP M Mode Acquisition Rate WFP

213 WFP M Mode Depth Delay WFP

214 WFP M Mode End of Acquisition WFP

215 WFP M Mode RAM Transfer-in WFP

216 WFP M Mode RAM Read-out WFP

217 WFP Line Segment RAM CPU Address WFP

218 WFP Line Segment RAM CPU Data WFP

219 WFP Line Segment RAM CPU Exhaustive WFP

21A WFP Waveform RAM CPU Address WFP

21B WFP Waveform RAM CPU Data WFP

21C WFP Waveform RAM Exhaustive WFP

21D WFP Waveform RAM Refresh WFP

21E WFP Non-Encoded Single Scroll Waveform WFP

21F WFP Non-Encoded Dual Scroll Waveform WFP

220 WFP Encoded Waveform with External Erase WFP


Bar

221 WFP Non-Encoded Waveform with Four WFP


Internal Erase Bars

222 WFP DMA Single Line WFP

223 WFP DMA Start and End Address WFP

224 WFP DMA Waveform WFP

225 WFP DMA Scale WFP

226 WFP Scanner 10MHZ Timer Interrupt IOB, WFP, STG, scanner control cable

27F CRP Dev_Test N/A (development tool)

280 CRP Write Mask Register Test CRP, FEC, SVC

281 CRP Config2 Register Test CRP, FEC, SVC

282 CRP Config1 Register Test CRP, FEC, SVC

283 CRP Config0 Register Test CRP, FEC, SVC

284 CRP Vidcontrol1 Register Test CRP, FEC, SVC

285 CRP Vidcontrol0 Register Test CRP, FEC, SVC

Module 8-26 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

286 CRP Input Buffer A Data Bus Test CRP, FEC, SVC

287 CRP Input Buffer A Addr Bus Test CRP, FEC, SVC

288 CRP Input Buffer A Mem Test CRP, FEC, SVC

289 CRP Input Buffer B Data Bus Test CRP, FEC, SVC

28A CRP Input Buffer B Addr Bus Test CRP, FEC, SVC

28B CRP Input Buffer B Mem Test CRP, FEC, SVC

28C CRP Input Buffer C Data Bus Test CRP, FEC, SVC

28D CRP Input Buffer C Addr Bus Test CRP, FEC, SVC

28E CRP Input Buffer C Mem Test CRP, FEC, SVC

28F CRP Interp LUT 15-0 Data Bus Test CRP, FEC, SVC

290 CRP Interp LUT 15-0 Addr Bus Test CRP, FEC, SVC

291 CRP Interp LUT 15-0 Mem Test CRP, FEC, SVC

292 CRP Interp LUT 31-16 Data Bus Test CRP, FEC, SVC

293 CRP Interp LUT 31-16 Addr Bus Test CRP, FEC, SVC

294 CRP Interp LUT 31-16 Mem Test CRP, FEC, SVC

295 CRP Plane A, Bank 0, Frame Buffer Data Bus CRP, FEC, SVC
Test

296 CRP Plane A, Bank 1, Frame Buffer Data Bus CRP, FEC, SVC
Test

297 CRP Frame Buffer Plane A Addr Bus Test CRP, FEC, SVC

298 CRP Frame Buffer Plane A Mem Test CRP, FEC, SVC

299 CRP Plane B, Bank 0, Frame Buffer Data Bus CRP, FEC, SVC
Test

29A CRP Plane B, Bank 1, Frame Buffer Data Bus CRP, FEC, SVC
Test

29B CRP Frame Buffer Plane B Addr Bus Test CRP, FEC, SVC

29C CRP Frame Buffer Plane B Mem Test CRP, FEC, SVC

29D CRP Frame Buffer Write Mask Test (Plane A) CRP, FEC, SVC

29E CRP Logical Region Map Data Bus Test CRP, FEC, SVC

29F CRP Logical Region Map Addr Bus Test CRP, FEC, SVC

2A0 CRP Logical Region Map Mem Test CRP, FEC, SVC

2A2 CRP Video Output Test CRP, FEC, SVC

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 27


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

2A3 CRP input buffer AB linear format coeff gen CRP, FEC, SVC
test

2A4 CRP input buffer BC linear format coeff gen CRP, FEC, SVC
test

2A5 CRP input buffer CA linear format coeff gen CRP, FEC, SVC
test

2A6 CRP lower unsigned interpolation test CRP, FEC, SVC

2A7 CRP upper unsigned interpolation test CRP, FEC, SVC

2A8 CRP lower signed interpolation test CRP, FEC, SVC

2A9 CRP upper signed interpolation test CRP, FEC, SVC

2A CRP Linear Interpolation Test CRP, FEC, SVC


A

2AB CRP Sector Interpolation Test CRP, FEC, SVC

2FE Read CRP Status Register N/A (utility tool)

300 Display EEPROM table Rev Check VPB FRU listing at the end of this Appendix.

301 Convert EEPROM table to Rev 0 Check VPB FRU listing

302 Convert EEPROM table to Rev 1 Check VPB FRU listing

305 Engineering THOMA Evaluation Tool N/A (development tool)

30A VPB Manually calibrate RAMDACs Check VPB FRU listing at the end

30B VPB Manually calibrate selected RAMDAC Check VPB FRU listing

30C VPB Sync CAL Tool Check VPB FRU listing

30D VPB GEN subc cal - need CAL station Check VPB FRU listing

30E VPB GEN rot phase cal - need CAL station Check VPB FRU listing

30F VPB GEN aqlut cal Check VPB FRU listing

310 VPB GEN mon bal - need Thoma/ref CRT Check VPB FRU listing

311 VPB GEN mon gamma curve - need Thoma/ Check VPB FRU listing
ref CRT

312 VPB LOAD gamma curves - WARNING: use Check VPB FRU listing
with caution

313 VPB LOAD tint settings - WARNING: use with Check VPB FRU listing
caution

314 VPB SELECT Gamma Curve Check VPB FRU listing

315 VPB SELECT Tint Setting Check VPB FRU listing

Module 8-28 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

316 VPB Show EEPROM Values Check VPB FRU listing

317 VPB auto-calibrate (VM700) Check VPB FRU listing


need CAL station

318 Field monitor balance entry tool Check VPB FRU listing

319 Field monitor tint entry tool Check VPB FRU listing

31A Edit Gamma Curve - WARNING: use with Check VPB FRU listing
caution

320 Playback External Video Source - need video Check VPB FRU listing
source

321 VPB Playback SVC digital Check VPB FRU listing

322 VPB Playback VHS loop Check VPB FRU listing

323 VPB Playback SVHS loop Check VPB FRU listing

324 VPB Playback BETACAM loop Check VPB FRU listing

325 VPB Playback AEGIS loop Check VPB FRU listing

326 VPB Playback AUX VHS loop Check VPB FRU listing

327 VPB Playback AUX SVHS loop Check VPB FRU listing

328 VPB enable svc video loop Check VPB FRU listing

329 VPB Playback Progressive GBR loop Check VPB FRU listing

32A VPB Playback Progressive CRT loop Check VPB FRU listing

340 VPB Reset Video Check VPB FRU listing

341 VPB Debug Menu - WARNING: use with Check VPB FRU listing
caution

342 Digital Pipeline Display Check VPB FRU listing

343 VPB/IOB Drift Report (All Paths) Check VPB FRU listing

344 VPB/IOB Prog Drift Report Check VPB FRU listing

345 VPB/IOB GBR Drift Report Check VPB FRU listing

346 VPB/IOB YUV Drift Report Check VPB FRU listing

347 VPB/IOB YC Drift Report Check VPB FRU listing

348 VPB/IOB YC Aux Drift Report Check VPB FRU listing

349 VPB/IOB Store Drift References Check VPB FRU listing


WARNING: use with caution

36A VPB Progressive Accuracy Test Check VPB FRU listing

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 29


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

36B VPB Display I2P Mode by Pixel Alignment Check VPB FRU listing
pattern
WARNING: use with caution

36C VPB Display I2P Mode Windows (preceding Check VPB FRU listing
pattern)
WARNING: use with caution

36D VPB Loop Through Litho Tool Check VPB FRU listing

36E VPB Loop Through SVC Tool Check VPB FRU listing

36F VPB I2P Manual Signature Tool Check VPB FRU listing

370 VPB ACAL Capture Read-out Tool Check VPB FRU listing

371 VPB P2I mode tool (preceding pattern) Check VPB FRU listing

372 VPB Access RAMDACs tool Check VPB FRU listing

373 VPB Readout RAMDACs tool Check VPB FRU listing

374 VPB Validate Signatures Check VPB FRU listing

375 VPB Raw Calibration Accuracy Report Check VPB FRU listing

376 VPB GBR Accuracy Test Check VPB FRU listing

377 VPB YPbPr Accuracy Test Check VPB FRU listing

378 VPB YC Accuracy Test Check VPB FRU listing

379 VPB CVID Accuracy Test Check VPB FRU listing

37A VPB YC AUX Accuracy Test Check VPB FRU listing

37B VPB Sync PLL Tool Check VPB FRU listing

37C VPB Report VPB state Check VPB FRU listing

37D VPB EEPROM Address Test Check VPB FRU listing

37E VPB EEPROM Data Test Check VPB FRU listing

37F VPB EEPROM Cell Test Check VPB FRU listing

380 VPB EEPROM Checksum Test Check VPB FRU listing

381 VPB RAMDAC Address Test Check VPB FRU listing

382 VPB RAMDAC Data Test Check VPB FRU listing

383 VPB RAMDAC Cell Test Check VPB FRU listing

384 VPB RAMDAC Ovl Cell Test Check VPB FRU listing

385 VPB RAMDAC PRM Cell Test Check VPB FRU listing

386 VPB AC Capture Address Test Check VPB FRU listing

Module 8-30 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

387 VPB AC Capture Data Test Check VPB FRU listing

388 VPB AC Capture Cell Test Check VPB FRU listing

389 VPB AQLUT Address Test Check VPB FRU listing

38A VPB AQLUT Data Test Check VPB FRU listing

38B VPB AQLUT Cell Test Check VPB FRU listing

38C VPB AC Generate Address Test Check VPB FRU listing

38D VPB AC Generate Data Test Check VPB FRU listing

38E VPB AC Generate Cell Test Check VPB FRU listing

38F VPB IO Test Check VPB FRU listing

390 VPB SPOT Interface Test Check VPB FRU listing

391 VPB XILINX Interface Test Check VPB FRU listing

392 VPB P2I Input Buffer Test Check VPB FRU listing

393 VPB P2I Conversion Test Check VPB FRU listing at the end

394 VPB Luma Delay Accuracy Test Check VPB FRU listing

395 VPB Comb Filter Test Check VPB FRU listing

396 VPB AQL/ACC Line Registration Test Check VPB FRU listing

397 VPB AQL/ACC Pixel Registration Test Check VPB FRU listing

398 VPB AQLUT AC Filter Test Check VPB FRU listing

399 VPB AQLUT Comb Filter Test Check VPB FRU listing

39A VPB AQLUT Test Check VPB FRU listing

39B VPB TBC FIFO Test Check VPB FRU listing

39C VPB AC Capture Int Test Check VPB FRU listing

39D VPB AC Capture Isolation Test Check VPB FRU listing

39E VPB AC Generate Test Check VPB FRU listing

39F VPB Taped AC Generate Test Check VPB FRU listing

3A0 VPB I2P Input Buffer Test Check VPB FRU listing

3A1 VPB I2P Control Test Check VPB FRU listing

3A2 VPB I2P Conversion Test Check VPB FRU listing

3A3 VPB I2P Output Buffer Test Check VPB FRU listing

3A4 VPB Sync Input Test Check VPB FRU listing

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 31


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

3A5 VPB Dynamic Track Test Check VPB FRU listing

3A6 VPB Calibration Accuracy Test Check VPB FRU listing

3A7 VPB Lithotripsy Video Path Test Check VPB FRU listing

3A8 VPB Superbright Test Check VPB FRU listing

3A9 VPB YC Input Filters Test Check VPB FRU listing

3A VPB Failure Detection Test Check VPB FRU listing


A

3AB VPB Failure Isolation Test Check VPB FRU listing

3AC VPB Temporary Test A N/A (development tool)

3A VPB Temporary Test B N/A (development tool)


D

3AE VPB Temporary Test C N/A (development tool)

3AF VPB CRT Calibration Range Test Check VPB FRU listing

3B0 VPB CRT Calibration Accuracy Test Check VPB FRU listing

3B1 VPB Sync Phase Test Check VPB FRU listing

3E2 VPB Display Progressive Colorbar (VM700 Check VPB FRU listing
only)

3E3 VPB Display MDF Test Pattern Check VPB FRU listing

3E4 VPB Display I2P Test Pattern Check VPB FRU listing

3E5 VPB Display P2I2P Debug Pattern Check VPB FRU listing

3E6 VPB Display Maximum Bandwidth Check VPB FRU listing


Checkerboard Pattern

3E7 VPB Display Vertical Ramp Test Pattern Check VPB FRU listing

3E8 VPB Display Horizontal Ramp Test Pattern Check VPB FRU listing

3E9 VPB Display P2I First Pixel Test Pattern Check VPB FRU listing

3EA VPB Display 100% White Pattern Check VPB FRU listing

3EB VPB Display 100% Green Pattern Check VPB FRU listing

3EC VPB Display 100% Blue Pattern Check VPB FRU listing

3ED VPB Display 100% Red Pattern Check VPB FRU listing

3EE VPB Display GBR Crosshatch Pattern Check VPB FRU listing

3EF VPB Display Colorbar Test Pattern Check VPB FRU listing

3F0 VPB Display SMPTE Colorbar Pattern Check VPB FRU listing

Module 8-32 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

3F1 VPB Display Quadrature Test Pattern Check VPB FRU listing

3F2 VPB Display Comb Test Pattern Check VPB FRU listing

3F3 VPB Display Crosshair Pattern Check VPB FRU listing

3F4 VPB Display Linear Test Pattern Check VPB FRU listing at the end

3F5 VPB Display YUV Ramp Test Pattern Check VPB FRU listing

3F6 VPB Display AQLUT COMB Test Pattern Check VPB FRU listing

3F7 VPB Display Linear Test Pattern2 Check VPB FRU listing

3F8 VPB Display Variable Gray Box Check VPB FRU listing

3F9 VPB Display Luma Ramp Pattern Check VPB FRU listing

3FA VPB Display SMPTE RP-133-1986 Check VPB FRU listing

3FB VPB Display 100% Window Check VPB FRU listing

3FC VPB Display 50% Window Check VPB FRU listing

3FD VPB Display 10% Window Check VPB FRU listing

3FE VPB Display 0% Window Check VPB FRU listing

3FF VPB Display Crosshatch Pattern Check VPB FRU listing

400 RP Dev_Test N/A (development tool)

401 RP Slave Side Code/Data Ram Memory Test RP, SVC

402 RP Slave Side Dual Port RAM Memory Test RP, SVC

403 RP Xilinx Initialization Test RP, SVC

404 RP Output Clock Ram Data Bus Test RP, SVC

405 RP Output Clock Ram Address Bus Test RP, SVC

406 RP Output Clock Ram Test RP, SVC

407 RP Output Clock Line Draw I/O Test RP,SVC

408 RP Output Clock Ram Transfer Test RP, SVC

409 RP Output Clock Draw Lines Test RP, SVC

40A RP Output Clock Video Ram Data Test RP, SVC

40B RP Output Clock Line Draw Full Test RP, SVC

40C RP Output Clock Fast Verification Test RP, SVC

40D RP Removal Addr Table Data Bus Test RP, SVC

40E RP Removal Addr Table Addr Bus Test RP, SVC

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 33


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

40F RP Removal Addr Table Memory Test RP, SVC

410 RP TV Line Table Data Bus Test RP, SVC

411 RP TV Line Table Addr Bus Test RP, SVC

412 RP TV Line Table Memory Test RP, SVC

413 RP Zone Control Table Data Bus Test RP, SVC

414 RP Zone Control Table Addr Bus Test RP, SVC

415 RP Zone Control Table Memory Test RP, SVC

416 RP Image Memory Table Data Bus Test RP, SVC

417 RP Image Memory Table Addr Bus Test RP, SVC

418 RP Image Memory Table Memory Test RP, SVC

419 RP Input Buffer 0 Data Bus Test RP, SVC

41A RP Input Buffer 0 Addr Bus Test RP, SVC

41B RP Input Buffer 0 Memory Test RP, SVC

41C RP Input Buffer 1 Data Bus Test RP, SVC

41D RP Input Buffer 1 Addr Bus Test RP, SVC

41E RP Input Buffer 1 Memory Test RP, SVC

41F RP Input Buffer 2 Data Bus Test RP, SVC

420 RP Input Buffer 2 Addr Bus Test RP, SVC

421 RP Input Buffer 2 Memory Test RP, SVC

422 RP Scan Path Test RP, SVC

423 RP Boundary Cell Test RP, SVC

424 RP Debug Mode R1 Signature test RP, SVC

425 RP Real Mode Signature Test RP, SVC

426 RP Interpolation Mode Signature Test RP, SVC

427 Extended RP Interpolation Mode Signature RP, SVC


Tests

428 RP Interrupt Test 1 (TIMEOUT*) RP, SVC

429 RP Interrupt Test 2 (LOC_TIMEOUT*) RP, SVC

42A RP Interrupt Test 3 (VBLNK*) RP, SVC

42B RP Interrupt Test 4 (V_INT1*) RP, SVC

42C RP Interrupt Test 5 (V_INT2*) RP, SVC

Module 8-34 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

42- RP Interrupt Test 6 (RMTE_BUSY) N/A (development tool)


D

42E RP Interrupt Test 7 (SPB_INTR) RP, SVC

42F RP Interrupt Test 8 (CDM_INT*) CDM, RP, SVC

430 RP Interrupt Test 9 (AQP_INT*) AQP, RP

431 RP Interrupt Test 10 (SPARE_INT*) N/A (development tool)

432 RP Input Buffer Write Address Generator Test RP

433 AQP To RP Interface Test AQP, RP

434 WFP-RP M-mode Remote Line Transfer Test WFP, RP

435 DSP-RP Remote Buffer Transfer Test scan converter remote bus cable, DSP, WFP, RP

436 ECRI Ram Data Bus Test RP

437 ECRI Ram Address Bus Test RP

438 ECRI Ram Memory Test RP

439 ECRI ID/IC Path Test RP

43A ECRI Azimuthal Filter Test

43B ECRI Axial Filter Test RP

43C ECRI Side Lobe Reduction (SLR) Filter Test RP

43D ECRI Line Test RP

43E ECRI Frame Test AQP, RP

43F AQP_DEV_TEST N/A (development tool)

440 AQP Arctan Translation Table Data Bus Test AQP, RP, SVC

441 AQP Arctan Translation Table Address Bus AQP, RP, SVC
Test

442 AQP Arctan Translation Table Memory Test AQP, RP, SVC

443 AQP Input Ultrasound Line Map Table Data AQP, RP,SVC
Bus Test

444 AQP Input Ultrasound Line Map Table AQP, RP, SVC
Address Bus Test

445 AQP Input Ultrasound Line Map Table AQP, RP, SVC
Memory Test

446 AQP Output Ultrasound Line Map Table Data AQP, RP,SVC
Bus Test

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 35


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

447 AQP Output Ultrasound Line Map Table AQP, RP, SVC
Address Bus Test

448 AQP Output Ultrasound Line Map Table AQP, RP, SVC
Memory Test

449 AQP Needle Visualization Peak Table Data Bus AQP, RP, SVC
Test

44A AQP Needle Visualization Peak Table Address AQP, RP, SVC
Bus Test

44B AQP Needle Visualization Peak Table Memory AQP, RP, SVC
Test

44C AQP Frame Sequence Register File Data Bus AQP, RP, SVC
Test

44D AQP Frame Sequence Register File Address AQP, RP, SVC
Bus Test

44E AQP Frame Sequence Register File Memory AQP, RP, SVC
Test

44F AQP Axial Filter Xilinx Internal Register Test AQP, RP, SVC

452 AQP Control/Status Registers Test AQP, RP, SVC

453 AQP Transmit Zone Crossfade Data Structure AQP, RP, SVC
Test

454 AQP Azimuthal Filter Table (1,1) Data Bus Test AQP, RP, SVC

455 AQP Azimuthal Filter Table (1,1) Address Bus AQP, RP, SVC
Test

456 AQP Azimuthal Filter Table (1,1) Memory Test AQP, RP, SVC

457 AQP Azimuthal Filter Table (4,1) Data Bus Test AQP, RP, SVC

458 AQP Azimuthal Filter Table (4,1) Address Bus AQP, RP, SVC
Test

459 AQP Azimuthal Filter Table (4,1) Memory Test AQP, RP, SVC

45A AQP Azimuthal Filter Table (5,1) Data Bus Test AQP, RP, SVC

45B AQP Azimuthal Filter Table (5,1) Address Bus AQP, RP, SVC
Test

45C AQP Azimuthal Filter Table (5,1) Memory Test AQP, RP, SVC

45D AQP Azimuthal Filter Table (3,1) Data Bus Test AQP, RP, SVC

45E AQP Azimuthal Filter Table (3,1) Address Bus AQP, RP, SVC
Test

45F AQP Azimuthal Filter Table (3,1) Memory Test AQP, RP, SVC

Module 8-36 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

460 AQP Azimuthal Filter Table (3,2) Data Bus Test AQP, RP, SVC

461 AQP Azimuthal Filter Table (3,2) Address Bus AQP, RP, SVC
Test

462 AQP Azimuthal Filter Table (3,2) Memory Test AQP, RP, SVC

463 AQP Azimuthal Filter Table (3,3) Data Bus Test AQP, RP, SVC

464 AQP Azimuthal Filter Table (3,3) Address Bus AQP, RP, SVC
Test

465 AQP Azimuthal Filter Table (3,3) Memory Test AQP, RP, SVC

466 AQP Azimuthal Filter Table (1,2) Data Bus Test AQP, RP, SVC

467 AQP Azimuthal Filter Table (1,2) Address Bus AQP, RP, SVC
Test

468 AQP Azimuthal Filter Table (1,2) Memory Test AQP, RP, SVC

469 AQP Azimuthal Filter Table (2,1) Data Bus Test AQP, RP, SVC

46A AQP Azimuthal Filter Table (2,1) Address Bus AQP, RP, SVC
Test

46B AQP Azimuthal Filter Table (2,1) Memory Test AQP, RP, SVC

46C AQP Azimuthal Filter Table (6,1) Data Bus Test AQP, RP, SVC

46D AQP Azimuthal Filter Table (6,1) Address Bus AQP, RP, SVC
Test

46E AQP Azimuthal Filter Table (6,1) Memory Test AQP, RP, SVC

46F AQP Azimuthal Filter Table (6,2) Data Bus Test AQP, RP, SVC

470 AQP Azimuthal Filter Table (6,2) Address Bus AQP, RP, SVC
Test

471 AQP Azimuthal Filter Table (6,2) Memory Test AQP, RP, SVC

472 AQP Post Axial Filter Table Data Bus Test AQP, RP, SVC

473 AQP Post Axial Filter Table Address Bus Test AQP, RP, SVC

474 AQP Post Axial Filter Table Memory Test AQP, RP, SVC

475 AQP Acoustic Frame Buffer 0.0 Data Bus Test AQP, RP, SVC

476 AQP Acoustic Frame Buffer 0.0 Address Bus AQP, RP, SVC
Test

477 AQP Acoustic Frame Buffer 0.0 Memory Test AQP, RP, SVC

478 AQP Acoustic Frame Buffer 1.0 Data Bus Test AQP, RP, SVC

479 AQP Acoustic Frame Buffer 1.0 Address Bus AQP, RP, SVC
Test

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 37


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

47A AQP Acoustic Frame Buffer 1.0 Memory Test AQP, RP, SVC

47B AQP Acoustic Frame Buffer 2.0 Data Bus Test AQP, RP, SVC

47C AQP Acoustic Frame Buffer 2.0 Address Bus AQP, RP, SVC
Test

47D AQP Acoustic Frame Buffer 2.0 Memory Test AQP, RP, SVC

47E AQP Acoustic Frame Buffer 0.1 Data Bus Test AQP, RP, SVC

47F AQP Acoustic Frame Buffer 0.1 Address Bus AQP, RP, SVC
Test

480 AQP Acoustic Frame Buffer 0.1 Memory Test AQP, RP, SVC

481 AQP Acoustic Frame Buffer 1.1 Data Bus Test AQP, RP, SVC

482 AQP Acoustic Frame Buffer 1.1 Address Bus AQP, RP, SVC
Test

483 AQP Acoustic Frame Buffer 1.1 Memory Test AQP, RP, SVC

484 AQP Acoustic Frame Buffer 2.1 Data Bus Test AQP, RP, SVC

485 AQP Acoustic Frame Buffer 2.1 Address Bus AQP, RP, SVC
Test

486 AQP Acoustic Frame Buffer 2.1 Memory Test AQP, RP, SVC

487 AQP Acoustic Frame Buffer 0.2 Data Bus Test AQP, RP, SVC

488 AQP Acoustic Frame Buffer 0.2 Address Bus AQP, RP, SVC
Test

489 AQP Acoustic Frame Buffer 0.2 Memory Test AQP, RP, SVC

48A AQP Acoustic Frame Buffer 1.2 Data Bus Test AQP, RP, SVC

48B AQP Acoustic Frame Buffer 1.2 Address Bus AQP, RP, SVC
Test

48C AQP Acoustic Frame Buffer 1.2 Memory Test AQP, RP, SVC

48D AQP Acoustic Frame Buffer 2.2 Data Bus Test AQP, RP, SVC

48E AQP Acoustic Frame Buffer 2.2 Address Bus AQP, RP, SVC
Test

48F AQP Acoustic Frame Buffer 2.2 Memory Test AQP, RP, SVC

490 AQP Acoustic Frame Buffer 0.3 Data Bus Test AQP, RP, SVC

491 AQP Acoustic Frame Buffer 0.3 Address Bus AQP, RP, SVC
Test

492 AQP Acoustic Frame Buffer 0.3 Memory Test AQP, RP, SVC

493 AQP Acoustic Frame Buffer 1.3 Data Bus Test AQP, RP, SVC

Module 8-38 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

494 AQP Acoustic Frame Buffer 1.3 Address Bus AQP, RP, SVC
Test

495 AQP Acoustic Frame Buffer 1.3 Memory Test AQP, RP, SVC

496 AQP Acoustic Frame Buffer 2.3 Data Bus Test AQP, RP, SVC

497 AQP Acoustic Frame Buffer 2.3 Address Bus AQP, RP, SVC
Test

498 AQP Acoustic Frame Buffer 2.3 Memory Test AQP, RP, SVC

499 AQP Test Registers Test AQP, RP, SVC

49A AQP Start of Frame Interrupt Test AQP, IOB, ZDT, STG

49B AQP Frame Acquisition Interrupt Test AQP, ZDT

49C AQP Acquisition Pipeline Partition A Test AQP, ZDT

49D AQP Acquisition Pipeline Partition B Test AQP, ZDT

49E AQP Acquisition Pipeline Partition C Test AQP, ZDT

49F AQP Acquisition Pipeline Partition D Test AQP, ZDT

4A0 AQP Crossfade Test AQP, ZDT

4A1 AQP Readout Sequence Complete Interrupt AQP, RP, SVC


Test

4A2 AQP Axial Filter Xilinx Initialization Test AQP, RP, SVC

4A3 RP Interrupt Test 9 (AQP_INT*) AQP, RP, SVC

4A4 AQP J-TAG Instruction Register Test AQP, RP, SVC

4A5 AQP J-TAG Boundary Scan Register Test AQP, RP, SVC

4A6 AQP J-TAG Pseudo Signature Test AQP, RP, SVC

4A7 AQP AD CONVERTER TEST N/A (development tool)

4EA AQP Readout Path Signature Test 0 AQP, RP, SVC

4EB AQP Readout Path Signature Test 1 AQP, RP, SVC

4EC AQP Readout Path Signature Test 2 AQP, RP, SVC

4ED AQP Readout Path Signature Test 3 AQP, RP, SVC

4EE AQP Readout Path Signature Test 4 AQP, RP, SVC

4EF AQP Readout Path Signature Test 5 AQP, RP, SVC

4F0 AQP Readout Path Signature Test 6 AQP, RP, SVC

4F1 AQP Readout Path Signature Test 7 AQP, RP, SVC

4F2 AQP Readout Path Signature Test 8 AQP, RP, SVC

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 39


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

4F3 AQP Readout Path Signature Test 9 AQP, RP, SVC

4F4 AQP Readout Path Signature Test 10 AQP, RP, SVC

4F5 AQP Readout Path Signature Test 11 AQP, RP, SVC

4F6 AQP Readout Path Signature Test 12 AQP, RP, SVC

4FD Digitize AQP Reference Voltage AQP, RP, SVC


need precision voltage board

4FE Is AQP 10Mhz there N/A (utility tool)

500 CDM Jumper ID Status Test CDM, RP

501 CDM Window Enable Status Test CDM, RP

502 CDM Initialization Status Test CDM, RP

528 CDM Persistence LUT SRAM Data March Test CDM

529 CDM Persistence LUT SRAM Address March CDM


Test

52A CDM Persistence LUT SRAM March C- Test CDM

52B CDM Persistence Reg File Memory Test CDM

52C CDM Persistence Bypass Mode Test CDM, RP

52- CDM Persistence Strip Mode Test CDM, RP


D

52E CDM Persistence Pass Through Mode Test CDM, RP

52F CDM Persistence Standard Primary Mode Test CDM, RP

530 CDM Persistence Standard Secondary Mode CDM, RP


Test

531 CDM Persistence Triggered Frame Mode Test CDM, RP

532 CDM Persistence Contrast Echo Mode Test CDM, RP

533 CDM Persistence Cine Playback Mode Test CDM, RP

534 CDM Persistence Alpha Coefficient Test CDM, RP

540 CDM Cine Counter Test CDM, RP

548 CDM Cine DRAM Data March Test CDM

549 CDM Cine DRAM March C- Test CDM

550 CDM Clear Image Memory VRAM Test CDM

558 CDM Image Memory (Ping) VRAM Data CDM


March Test

Module 8-40 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

559 CDM Image Memory (Pong) VRAM Data CDM


March Test

55A CDM Image Memory (Ping) VRAM March C- CDM


Test

55B CDM Image Memory (Pong) VRAM March C- CDM


Test

55C RP-CDM Interface Test CDM, RP

560 CDM Logical Region Map SRAM Data March CDM


Test

561 CDM Logical Region Map SRAM Address CDM


March Test

562 CDM Logical Region Map SRAM March C- CDM


Test

563 CDM Column Start Address SRAM Data CDM


March Test

564 CDM Column Start Address SRAM Address CDM


March Test

565 CDM Column Start Address SRAM March C- CDM


Test

566 CDM SAM Controller SRAM Data March Test CDM

567 CDM SAM Controller SRAM Address March CDM


Test

568 CDM SAM Controller SRAM March C- Test CDM

569 CDM Image Controller Row Address Status CDM


Test

56A CDM Image Controller Column Address CDM


Signature Test

570 CDM Interpolation SRAM Data March Test CDM

571 CDM Interpolation SRAM Address March Test CDM

572 CDM Interpolation SRAM March C- Test CDM

573 CDM Interpolation Progressive Pipeline CDM


Signature Test

574 CDM Interpolation Single Image Signature CDM, RP


Test

575 CDM Interpolation Dual Image Signature Test CDM, RP

576 CDM Interpolation Quad Image Signature Test CDM, RP

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 41


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

577 CDM Interpolation Decimate Mask Signature CDM, RP


Test

578 SCC Scope Loop N/A (utility tool)

579 WFP-RP-CDM Subsystem M-mode Test CDM, RP, WFP

57A AQP-RP-CDM Subsystem B-Mode Test CDM, AQP, RP

57B RP_H1_clk_loop N/A (utility tool)

580 UIC Master Side Dual Port RAM Data Bus Test UIC, IOB, SVC

581 UIC Master Side Dual Port RAM Addr Bus Test UIC, IOB, SVC

582 UIC Master Side Dual Port RAM Memory Test UIC, IOB, SVC

583 UIC Slave Side Dual Port RAM Memory Test UIC, IOB

584 UIC Slave Side SRAM Memory Test UIC, IOB

590 UIC Identification Test UIC, UIP, UIQ, UDC

591 UIC Reference Voltage Test UIC, IOB, MDI

592 UIC LCD Test UIC, UIP

593 UIC LED Driver Test UIC

594 UIC LED Test UIC, UIP

595 UIC Keyboard Legend DAC Test UIC

596 UIC Keyboard Push Button Indicator DAC Test UIC

597 UIC Keyboard Encoder Assignment DAC Test UIC

598 UIC LCD Contrast DAC Test UIC

599 UIC Downlighting DAC Test QWL, UIC

59A UIC LCD Backlighting DAC Test UIC

59B UIC UDC ID and EEPROM Data Verification UDC, UIC


Tests

59C UIC Sound Generator and Audio PROM UIC


Output Test

59D UIC Audio Sound DAC Test UIC

59E UIC Audio Volume DAC Test UIC

59F UIC EEPOT Wiper Counter and Register UIC


Memory Test

5C0 User Interface Keyboard Test N/A (utility tool)

5C1 UIC Interactive Test Menu N/A (utility tool)

Module 8-42 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

5C2 UIC Interactive Keyboard Scan Test N/A (utility tool)

5C3 UIC Interactive Optical Encoder Test N/A (utility tool)

5C4 UIC Interactive DGC Slide Pot Test N/A (utility tool)

5C5 UIC Interactive Trackball Test N/A (utility tool)

5C6 UIC Interactive Audio Test N/A (utility tool)

5D0 UIC Interactive Four Corners Test N/A (development tool)

600 SVC2 PIC Internal Registers Test SVC

601 SVC2 MASK Register Test SVC

602 SVC2 System Memory Address and Data SVC


Busses Test

603 SVC2 System Memory Background Test SVC

604 SVC2 System Memory Increment Test SVC

605 SVC2 System Memory March C Test SVC

606 SVC2 Graphic Memory Data Test SVC

607 SVC2 Graphic Memory Address Test SVC

608 SVC2 Graphic Memory Background Test SVC

609 SVC2 Graphic Memory Increment Test SVC

60A SVC2 Graphic Memory Mask Test SVC

60B SVC2 Pixel Region Memory Background Test SVC

60C SVC2 Pixel Region Memory Increment Test SVC

60D SVC2 Pixel Region Memory Transfer Cycle SVC


Test

60E SVC2 Battery Backed Memory Data Test SVC, RP

60F SVC2 Battery Backed Memory Address Test SVC, RP


WARNING: do not power off in middle of test
or BBM data will be lost

610 SVC2 Battery Backed Memory Background SVC, RP


Test
WARNING: do not power off in middle of test
or BBM data will be lost

611 SVC2 Battery Backed Memory Increment Test SVC, RP


WARNING: do not power off in middle of test
or BBM data will be lost

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 43


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

612 SVC2 Coprocessor Test SVC

613 SVC2 Region Control Map Background Test SVC

614 SVC2 Region Control Map Increment Test SVC

615 SVC2 Graphic Palette Background Test SVC

616 SVC2 Graphic Palette Increment Test SVC

617 SVC2 Image Palette Background Test SVC

618 SVC2 Image Palette Increment Test SVC

619 SVC2 Field Control Background Test SVC

61A SVC2 Field Control Increment Test SVC

61B SVC2 Accumulator Input Map Background SVC


Test

61C SVC2 Accumulator Input Map Increment Test SVC

61D SVC2 Real Time Clock Interrupt Test SVC

61E SVC2 Graphic B/W Patterns Test SVC

61F SVC2 Graphic Color Patterns Test SVC

620 SVC2 Constant Accumulation Test SVC

621 SVC2 Pixel Region Memory Checksum Test SVC

622 SVC2 Image and Graphic Mixing Test SVC

623 SVC2 WFP Waveforms System Graphics WFP, SVC


Signature Test

625 SVC2 Serial Port Test N/A (utility tool)

626 CDM2 SVC2 B-Mode Image Signature Test CDM, SVC

627 CRP SVC2 Expanded Color Doppler Map CRP, SVC


Signature Test

628 SVC2 B/W and CDI Mix Low Signature Test CRP, CDM, SVC

629 SVC2 B/W and CDI Mix High Signature Test SVC, CRP, CDM

62A SVC2 B/W and CDI Threshold Signature Test SVC, CRP, CDM

62B SVC2 System Accumulation Test SVC, CRP, CDM

64E SVC2 CDI Color Display N/A (utility tool))

64F SVC2 B/W B-Mode Display N/A (utility tool)

650 IOB Audio Control Port Test IOB, SVC

651 IOB Scanner Address Port Test IOB, SVC

Module 8-44 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

652 IOB Video Out Control Port Test IOB, SVC

653 IOB Control A Port Test IOB, SVC

654 IOB Peripheral Control Port Test IOB, SVC

655 IOB Power Margin Control Port Test IOB, SVC

656 IOB Power Mux Control Port Test IOB, SVC

657 IOB Power Control Port Test IOB, SVC

658 IOB Serial Port A Scratch Pad Register Test IOB, SVC

659 IOB Serial Port B Scratch Pad Register Test IOB, SVC

65A IOB Serial Port C Scratch Pad Register Test IOB, SVC

65B IOB Serial Port D Scratch Pad Register Test IOB, SVC

662 IOB DAS Reset Test IOB

663 IOB DAS Access Test IOB

664 IOB DAS Instruction Ram Test IOB

665 IOB DAS Full Calibration Test IOB

666 IOB DAS Watchdog Test IOB

667 IOB Power Monitoring Interrupt Test IOB, SVC

668 IOB VIDEO PATH 4 Test VPB, IOB

669 IOB VIDEO PATH 5 Test VPB, IOB

66A IOB VIDEO PATH 6 Test VPB, IOB

66B IOB VIDEO PATH 7a Test VPB, IOB

66C IOB VIDEO PATH 7b Test VPB, IOB

66D IOB VIDEO PATH 9 Test VPB, IOB

66E IOB VIDEO PATH B Test VPB, IOB

66F Power supply/temperature/fan test IOB, PPS power supply, main power harness and
scanner voltage cables, MDI, ZDT, SCMB, SMB,
SVC

670 Scanner power supply tests scanner supplies (+5V digital, +5V analog, ±7.5V,
±15V

671 Scan converter power supply tests scan converter supplies (_5V, ±12V, +12V
peripheral)

672 300 VDC power supply test +300 VDC

673 Internal 120 VAC test 120 VAC

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 45


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

674 Temperature sensor tests (0 to 40 C) scanner and scan converter temperature sensor

675 Temperature sensor tests (8 to 50 C: ESS) scanner and scan converter temperature sensor
same as test 674 but has wider limits for
temperature stress cycles in manufacturing

676 Temperature to fan servo tests temperature maximum detector and +12V fan

677 PPS setpoint voltage accuracy tests PPS

678 Scanner power supply noise tests N/A (utility tool)

679 Scan converter power supply noise tests N/A (utility tool)

67A 300 VDC power supply noise test N/A (utility tool)

67B Internal 120 VAC noise test N/A (utility tool)

67C Temperature sensor noise tests N/A (utility tool)

67D Temperature to fan servo noise tests N/A (utility tool)

67E PPS setpoint voltage noise tests N/A (utility tool)

69F IOB Developmental Tests N/A (development tool)

6A0 IOB External Composite Sync Test IOB, VPB


needs custom external cables

6A1 IOB VIDEO PATH 0 Test IOB, VPB

6A2 IOB VIDEO PATH 1 Test IOB, VPB

6A3 IOB VIDEO PATH 2 Test IOB, VPB

6A4 IOB VIDEO PATH 3 Test IOB, VPB

6A5 IOB VIDEO PATH 8 Test IOB, VPB

6A6 IOB VIDEO PATH A Test IOB,VPB

6A7 IOB Margin Control Test IOB

6A8 IOB Auto Area Measurement Test IOB

6A9 IOB BCD Status Port Test IOB


needs custom external cables

6A IOB Color Pattern IOB, VPB


A

6AB IOB Video Test Sequence IOB, VPB

6AC IOB DAS System Voltage Measurements N/A (utility tool)

6A IOB Serial Debug N/A (utility tool)


D

Module 8-46 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

6AE Get IOB Port Value N/A (utility tool)

6AF Set IOB Port Value N/A (utility tool)

6B0 Report DCIDIG Version N/A (utility tool)

6B1 DCI DRAM Configuration Report N/A (utility tool)

6B2 DCI Global Memory Address and Data Busses DCI


Test

6B3 DCI Global Memory March-C Test DCI

6B4 DCI Global Memory Checkboard Test DCI

6B5 DCI Video Buffer March-C Test DCI

6B6 DCI Video Buffer Checkboard Test DCI

6B7 DCI Video Parameters Memory Test DCI

6B8 DCI Timer 0 Interrupt Test DCI

6B9 DCI Realtime Clock Interrupt Test DCI

6BA DCI Sonic Watchdog Register Test DCI

6BB DCI Load CAM Test DCI

6BC DCI Sonic Address Bus Test DCI

6BD DCI Sonic MAC Loopback Test DCI

6C0 DCI Transceiver Loopback with CAM Test DCI

6C1 DCI SCSI Scratch Register Test SCSI cable, hard drive, MO drive, MDI, IOB

6C2 DCI SCSI DMA Mem to Mem Test SCSI bus (cable), hard drive, MO drive, DCI

6C3 DCI SCSI Test Disk Ready SCSI bus (cable), hard drive, MO drive, DCI

6C4 DCI SCSI Disk Read/Write Test SCSI bus (cable), hard drive, MO drive, DCI

6C5 DCI Video Buffer Transfer Cycle Test DCI

6C6 DCI Buffer Control Register Test DCI

6C7 DCI Sequence Control Register Test DCI

6C8 DCI Signature Register Test DCI

6C9 DCI Display Buffers Test DCI

6CA DCI Capture Buffers Test DCI-IOB cable, SVC, DCI

6CB DCI RLE Pass Compression Test DCI

6CC DCI RLE Pass Decompression Test DCI

6CD DCI Region of Interest Comp Test DCI

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 47


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

6CE DCI Region of Interest Decomp Test DCI

6CF DCI Region of Interest Test DCI

6D0 DCI RLE Compression/Decompression Test DCI

6D1 DCI JPEG Card Version Report DCI

6D2 DCI L765 Compression Init Test DCI

6D3 DCI L765 Decompression Init Test DCI

6D4 DCI L765 DMA Init Test DCI

6D5 DCI L745 Compression Init Test DCI

6D6 DCI L745 Decompression Init Test DCI

6D7 DCI JPEG Compression and Decompression DCI


Test

6D8 DCI JPEG File Decompression Test DCI

6D9 DCI Audio Register Test DCI

6D DCI Audio PIO External Loopback Test N/A (development tool)


A

6DB DCI Audio DMA Internal Loopback Test DCI

6DC DCI boot PROM based DRAM “march c-” test DCI

6E0 DCI Dual Port Ram Test N/A (utility tool)

6E1 DCI Video Path Test N/A (utility tool)

6E2 DCI Compression and Decompression Path N/A (utility tool)


Test

6E3 DCI RLE Codec Test N/A (utility tool)

6E4 DCI JPEG Codec Test N/A (utility tool)

6E5 DCI Maximum Compression Length Feature N/A (utility tool)


Test

6E6 DCI Global Memory Interface Test N/A (utility tool)

6E7 DCI MO Drive Test Unit Ready Test SCSI cable, MO drive, hard drive, MDI, IOB

6E8 DCI MO Drive Read Write Test SCSI cable, MO drive, hard drive, MDI, IOB

6F0 DCI Debug enable/disable toggle DCI

6FE SVC2 Display AEGIS N/A (utility tool)

6FF DCI Load and Execute LynxOS DCI

700 SCP/scanner diagnostics revision N/A (utility tool)

Module 8-48 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

701 SCP/scanner set report level N/A (utility tool)

702 SCP UART enable N/A (utility tool)

703 SCP UART disable N/A (utility tool)

704 SCP BREAKPOINT toggle N/A (development tool)

705 SCP BREAKPOINT status N/A (development tool)

71e SCP development test N/A (development tool)

71f SCP boot PROM based DRAM “march c-” test SCP

720 SCP ID port read N/A (utility tool)

721 SCP LED blink test N/A (utility tool)

722 SCP DRAM data march test SCP

723 SCP DRAM address march test SCP

724 SCP DRAM “march c-” test SCP

725 SCP pointer sequence RAM data march test SCP

726 SCP pointer sequence RAM address march test SCP

727 SCP pointer sequence RAM “march c-” test SCP

728 SCP flash EEPROM SIMM test N/A (utility tool)

729 SCP timer 1 access test SCP

72A SCP timer 2 access test SCP

72B SCP interrupt controller 1 access test SCP

72C SCP interrupt controller 2 access test SCP

72- SCP software interrupt test SCP


D

72E SCP timer 1 element 0 interrupt test SCP

72F SCP timer 1 element 1 interrupt test SCP

730 SCP timer 1 element 2 interrupt test SCP

731 SCP timer 2 element 0 interrupt test SCP

732 SCP timer 2 element 1 interrupt test SCP

733 SCP timer 2 element 2 interrupt test SCP

734 PBUS timeout test SCP

740 SCP ZDT RAM data march test ZDT, SCP

741 SCP ZDT RAM address march test ZDT, SCP

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 49


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

742 SCP ZDT RAM “march c-” test ZDT, SCP

743 SVC2 ZDT RAM data march test SVC

744 SVC ZDT RAM address march test SVC

745 SVC2 ZDT RAM “march c-” test SVC

746 ZDT memory write line number and type N/A (utility tool)

747 ZDT DMA write line number and type (user N/A (utility tool)
values)

748 ZDT get board ID N/A (utility tool)

749 ZDT get interrupt status register N/A (utility tool)

74A ZDT AQP line number I/O write test AQP,IOB, ZDT, SCP, RP, SVC

74B ZDT AQP line type I/O write test AQP,IOB, ZDT, SCP, RP, SVC

74C ZDT AQP line number dma I/O write test AQP,IOB, ZDT, SCP, RP, SVC

74D ZDT AQP line type dma I/O write test AQP,IOB, ZDT, SCP, RP, SVC

74E ZDT ZBUS read timeout test ZDT, SCP, ZDL, ZIP

74F ZDT ZBUS write timeout test ZDT, SCP, ZDL, ZIP

751 ZBUS timeout and interrupt test ZDT, SCP

752 ZDT scanner state port test ZDT, STG, SCP

760 ZDL DL Switch time test ZDT, ZDL, SCP

761 ZDL get board ID N/A (utility tool)

762 ZDL get diag/aux port N/A (utility tool)

763 ZDL get transducer IDs N/A (utility tool)

764 ZDL select DL N/A (utility tool)

765 ZDL select thermal sense N/A (utility tool)

766 ZDL Tx test amp control N/A (utility tool)

767 ZDL cal amp control N/A (utility tool)

768 ZBUS status read N/A (utility tool)

769 ZBUS data read N/A (utility tool)

76A ZBUS data write N/A (utility tool)

77F ZDL relay check utility N/A (utility tool)

7A0 ZIP read PCA ID ZIP, ZDT, SCP

7A2 ZIP read XDCR ID N/A (utility tool)

Module 8-50 Aspen Service Training Manual P/N 59163 Rev. 1


Acuson Confidential Diagnostic Test List

TES TEST DESCRIPTION FRUS


T

7A4 ZIP read DIAG PORT N/A (utility tool)

7A5 ZIP select XDCR N/A (utility tool)

7A6 ZIP select thermal sense N/A (utility tool)

7A7 ZIP control ATDI power supplies N/A (utility tool)

7A8 ZIP get interrupt status N/A (utility tool)

7AE ZIP XDCR switch time ZIP, ZDT, SCP

7AF ZIP ATDI MCTA read/write test N/A (utility tool)

7B0 ZIP initialize board N/A (utility tool)

7B1 ZIP ATDI BAT ROM write N/A (utility tool)

7E0 PBUS SCP test mode DMA_II to DCC0 RAM DCC0, SCP
test (8 bytes)

7E1 PBUS SCP timer initiated test mode DMA_II to DCC0, SCP
DCC0 (8 bytes)

7E2 PBUS DMA timeout (SCP error trap) interrupt SCP


test

7E4 Fire one tx/rx line once N/A (utility tool)

7E5 Fire each tx/rx line once N/A (utility tool)

7E6 Fire tx/rx line continuous, incr line on kbhit N/A (utility tool)

7E7 Get thermal sense A/D reading N/A (utility tool)

7E8 Put hex PPS command N/A (utility tool)

7E9 Get hex PPS status N/A (utility tool)

7EA PPS3 readback status calibration accuracy test PPS, ZDT, SCP, OVP

7ED PPS3 setpoint settling time test PPS, ZDT, SCP

7EE DCC0 memory page test DCC0, SCP

7EF DCC1 memory page test DCC1, SCP

7F0 DCC0 background memory test DCC0, SCP

7F1 DCC1 background memory test DCC1, SCP

7F2 DCC0 increment memory test DCC0, SCP

7F3 DCC1 increment memory test DCC1, SCP

7F6 DCC0 signature test DCC0, SCP

7F7 DCC1 signature test DCC1, SCP

7F8 Memex checksum test MEX0, MEX1, MEX2, SCP

P/N 59163 Rev. 1 Aspen Service Training Manual Module 8- 51


Module 8 - Diagnostic Tools Acuson Confidential

TES TEST DESCRIPTION FRUS


T

7F9 Interrupt SVC2->SCP test ZDT, IOB, SCP, SVC

7FA Interrupt SCP->SVC2 test ZDT, IOB, SVC, SCP

7FB Interrupt SVC2->SCP NMI test ZDT, IOB, SCP, SVC

7FC SCP scanner state 0 interrupt test STG, SCP

7FF PPS3 setpoint settling time utility PPS, ZDT, SCP

VPB FRU LIST The following error codes are reported only when running remote
diagnostics and there is a VPB test failure. In the current version of
the diagnostics, the error codes will only be displayed on the remote
terminal screen (i.e., these error codes are not displayed on the
Aspen system monitor).

ERROR ERROR CODES FRU INDICTMENTS


NUMBERS
0 NO FAILURE None
1 UNKNOWN FAILURE N/A
2 HW CONFIG VPB, RP, SVC
3 SVC VIDEO SVC,RP
4 DIGITAL INPUT VPB, SVC-VPB digital cable, SVC
5 DIGITAL PIPELINE VPB
6 DIGITAL OUTPUT VPB, SVC, RP, SCMB
7 ANALOG INPUT VPB, IOB, RP
8 RP RASTER RP, SVC
9 LOCAL RASTER VPB,RP
10 SYSTEM RAM VPB, SVC, RP
11 IO REGISTERS VPB, RP
12 LOCAL INTERFACES VPB
13 SVC INTERRUPT VPB, SVC
14 CALIBRATED ANALOG LOOP VPB, IOB

Module 8-52 Aspen Service Training Manual P/N 59163 Rev. 1