Sei sulla pagina 1di 93

SIPROTEC 5 /

DIGSI 5 Basic Course


10 DIGSI 5 - Configure
www.siemens.com/poweracademy Copyright © Siemens AG 2012. All rights reserved.
Learning Target

You will learn…


 Learn how to configure a SIPROTEC 5 device
 Learn how to work with the editors needed for configuration
 Get familiar with the workflow of the editors

Copyright © Siemens AG 2012. All rights reserved.


10 DIGSI 5 - Configure
Version: D_02_Page 2 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Content

Content

 How to handle DIGSI 5

Copyright © Siemens AG 2012. All rights reserved.


 Working with Single Lines
 Adding devices to the project
 Configuring devices
 Adjust settings
 Route information
 Extensibility by function charts
 Create Display pages
 Configure the communication

10 DIGSI 5 - Configure
Version: D_02_Page 3 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
How to handle DIGSI 5
Installing DIGSI 5

There is one installation routine for all


DIGSI 5 editions and languages
 The functionality available does not depend on
what you install
 But it depends on the license key you specify later

Copyright © Siemens AG 2012. All rights reserved.


Upgrading to a more feature-rich DIGSI 5 edition just means
providing a new license key

10 DIGSI 5 - Configure
Version: D_02_Page 4 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
How to handle DIGSI 5
Installing DIGSI 5

Run setup.exe from the DIGSI 5 setup

 You can choose the language of the installation

Copyright © Siemens AG 2012. All rights reserved.


Setup installs all available languages of DIGSI 5

10 DIGSI 5 - Configure
Version: D_02_Page 5 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
How to handle DIGSI 5
Installing DIGSI 5

Choose location where to install DIGSI 5

Copyright © Siemens AG 2012. All rights reserved.


10 DIGSI 5 - Configure
Version: D_02_Page 6 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
How to handle DIGSI 5
Three ways of starting DIGSI 5

OR OR OR

Copyright © Siemens AG 2012. All rights reserved.


Choose in Start menu: (Double) Click on (Double) Click on a
DIGSI 5.exe: DIGSI 5 project:

Siemens Energy
DIGSI 5 V1.00
DIGSI 5 V1.00
DIGSI 5.exe Myproject.d5v1

10 DIGSI 5 - Configure
Version: D_02_Page 7 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
How to handle DIGSI 5
Starting DIGSI 5...

Copyright © Siemens AG 2012. All rights reserved.


10 DIGSI 5 - Configure
Version: D_02_Page 8 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
How to handle DIGSI 5
Installing your license(s)

 After starting DIGSI


5 you have the
choice

Copyright © Siemens AG 2012. All rights reserved.


 Run DIGSI 5 as
Compact edition
 Install a license
for DIGSI 5
Standard or
Premium
 Start DIGSI 5 in
Trial mode

10 DIGSI 5 - Configure
Version: D_02_Page 9 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
How to handle DIGSI 5
Installing your license(s) using license manager

 Install license(s)
 From USB-stick
 From other computers

Copyright © Siemens AG 2012. All rights reserved.


 You can store multiple
licenses on your computer
and
 Move them to other
machines on the
network
 Let other machines
grab them from that
machine

10 DIGSI 5 - Configure
Version: D_02_Page 10 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
How to handle DIGSI 5
DIGSI Device Drivers

Copyright © Siemens AG 2012. All rights reserved.


DIGSI 5 device drivers and firmware updates are all packaged
in so called

„DIGSI device drivers (DDD)“

Container for transport of all loadable components to the user.

10 DIGSI 5 - Configure
Version: D_02_Page 11 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Excursion
How to read DDD names

Example:
7SA85 FW-V01.02 CFG-V01.01 DDD-V01.00

Device type Firmware Configuration DDD version

Copyright © Siemens AG 2012. All rights reserved.


version version (continuous counter incr.
when FW or CFG changes)

Definition of version:

Vvv.xy

Major Release
Minor Release

Maintenance Release

10 DIGSI 5 - Configure
Version: D_02_Page 12 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
How to handle DIGSI 5
Importing device drivers

Import the device drivers you need: ToolsImport device drivers

Copyright © Siemens AG 2012. All rights reserved.


10 DIGSI 5 - Configure
Version: D_02_Page 13 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
How to handle DIGSI 5
Create or open a project

 Create project using:


File  New

Copyright © Siemens AG 2012. All rights reserved.


 Or open an existing one
File  Open

 Or choose one of the


previously opened projects

10 DIGSI 5 - Configure
Version: D_02_Page 14 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Content

Content

 How to handle DIGSI 5

Copyright © Siemens AG 2012. All rights reserved.


 Working with Single Lines
 Adding devices to the project
 Configuring devices
 Adjust settings
 Route information
 Extensibility by function charts
 Create Display pages
 Configure the communication

10 DIGSI 5 - Configure
Version: D_02_Page 15 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines
Three ways of creating single-lines

OR OR OR

Copyright © Siemens AG 2012. All rights reserved.


Import from file: Use templates from Build it yourself using
library: The symbol library:

ELCAD files
From Topologies
TEAX
SCD, SSD

10 DIGSI 5 - Configure
Version: D_02_Page 16 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines
Switching between standards

IEC ANSI

Copyright © Siemens AG 2012. All rights reserved.


akV bV
OR akV bV
?
3 3 3 3
 Choose OptionsSettings and select the “DIGSI” page to toggle standard
 The standard can be even changed on existing single-line diagrams
 Select standard before creating display pages from single lines

10 DIGSI 5 - Configure
Version: D_02_Page 17 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines
Example 1: Create using templates from library

 Start single-line editor with


double click on „Single-line
configuration“ in project
tree.

Copyright © Siemens AG 2012. All rights reserved.


 Drag and drop template
from library to editor

Drag template
From library

10 DIGSI 5 - Configure
Version: D_02_Page 18 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines (IEC)
Example 1: Create using templates from library

 Drag and drop template


from library to editor
 To extend busbar with new

Copyright © Siemens AG 2012. All rights reserved.


bays, drop templates over
existing busbars

Drag template
From library

10 DIGSI 5 - Configure
Version: D_02_Page 19 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines (IEC)
Example 1: Create using templates from library

 Drag and drop template


from library to editor
 To extend busbar with new

Copyright © Siemens AG 2012. All rights reserved.


bays, drop templates over
existing busbars

10 DIGSI 5 - Configure
Version: D_02_Page 21 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines
Example 2: Create using symbols from library

 Drag and drop elements


from library to editor
 Elements get automatically

Copyright © Siemens AG 2012. All rights reserved.


connected if dropped close
to bottom of other element
 Rename elements

Drag element
From library

10 DIGSI 5 - Configure
Version: D_02_Page 23 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines (IEC)
Example 2: Create using symbols from library

 Bays are created


automatically
 When dropping in existing

Copyright © Siemens AG 2012. All rights reserved.


bay it gets extended,
otherwise a new bay is
created
 Manually connect
elements by selecting one
connection point and
dragging to other
Drag element
From library

10 DIGSI 5 - Configure
Version: D_02_Page 24 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines (IEC)
Set basic primary equipment data

 Select primary equipment


like voltage and current
transformers in SLE
 Set their basic settings

Copyright © Siemens AG 2012. All rights reserved.


(e.g. ratios) in their
properties
 After you added and
connected a device you
can take over those
settings to all connected
device (more details
coming in some slides)

10 DIGSI 5 - Configure
Version: D_02_Page 26 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Adding devices to the project
Add new device

OR OR
Create device by product code: Use Devices & Networks editor:
Choose Add new device in Choose device in library

Copyright © Siemens AG 2012. All rights reserved.


project tree Drag and drop Application
Specify short or long product template from library to editor
code
Choose Application template
that fits best

In Devices & Networks editor (device view)


Add front panels
Add communication modules

10 DIGSI 5 - Configure
Version: D_02_Page 28 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Adding devices to the project
Add new device using product code

 Add new device by clicking


„Add new device“ in project
tree.
 Copy product code (long or
short) from the order

Copyright © Siemens AG 2012. All rights reserved.


configurator or device label
 If short product code is not
recognized DIGSI 5 tries to
update list of short product
codes from the internet
 Significant features of your
device are displays
 Select application template
that fits best your needs
(you can later add and
remove functionality as
needed)

10 DIGSI 5 - Configure
Version: D_02_Page 29 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Structure of an Protection Application

BB 1 connection between FGs and FG <-> MP,


configurable via DIGSI
Interface of FG
„movable“ functions
SI= serial interface, PDC=protection data com.
7SL86: AT „Basic“

Copyright © Siemens AG 2012. All rights reserved.


U4
QAmm
I1 FG Line FG CB
T1.1 I2 MP
I - 3 ph 51 51 N 50
U-3 ph S 1
I3 CT-3ph 1 U-1 ph S 1
U-3 ph S 2
T1.2 I4
I - PTstar 78 U-1 ph S 2

U1 I - 3 ph
MP U - 3 ph 21
T5 U2 VT-3ph 1
U3 IF IF
SOTF FL

to
I - parl
87 BI CB QA
Ctrl CB
FG PDI BO
SI PDI PDI PDI Int . lk

10 DIGSI 5 - Configure
Version: D_02_Page 30 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Structure of an Protection Application
Preparation phase (not needed for application templates)

 Connect the physical current and voltage terminals with the


logical measuring points in the Measuring-point routing
editor.
BB 1 connection between FGs and FG <-> MP,
configurable via DIGSI
Interface of FG

Copyright © Siemens AG 2012. All rights reserved.


„movable“ functions
SI= serial interface, PDC=protection data com.
7SL86: AT „Basic“
U4
QAmm
I1 FG Line FG CB
T1.1 I2 MP
I- 3 ph 51 51 N 50
U-3 ph S 1
I3 CT-3ph 1 U-1 ph S 1
U-3 ph S 2
T1.2 I4
I- PTstar 78 U-1 ph S 2

U1 I- 3 ph
MP U - 3 ph 21
T5 U2 VT-3ph 1
U3 IF IF
SOTF FL

to
I- parl
87 BI CB QA
Ctrl CB
FG PDI BO
SI PDI PDI PDI Int . lk

 Connect measuring-points to function groups and


functions groups underneath each other in the
Function-group connections editor.

10 DIGSI 5 - Configure
Version: D_02_Page 31 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Structure of an Protection Application
Preparation phase (not needed for application templates)

 You can connect measuring points to function


groups in two ways
 In function-group connections editor
 In Single-line configuration editor

Copyright © Siemens AG 2012. All rights reserved.


10 DIGSI 5 - Configure
Version: D_02_Page 32 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines
Define the functionality of the device

 To add functionality drag


function groups, functions
and function blocks from
library to device in SLE
(or to project tree)

Copyright © Siemens AG 2012. All rights reserved.


 Or copy existing
(parameterized) elements
and paste them
 Rename elements
Drag FG, FN, FB
from library  Select elements and delete
them if not needed
(context menu)
 Tips:
 Change setting in
properties of elements
 Add comments

10 DIGSI 5 - Configure
Version: D_02_Page 34 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Structure of an Protection Application
Primary equipment connections

 Connect the primary equipment with measuring points in


the Single-line configuration editor

Copyright © Siemens AG 2012. All rights reserved.


BB 1 connection between FGs and FG <-> MP,
configurable via DIGSI
Interface of FG
„movable“ functions
SI= serial interface, PDC=protection data com.
7SL86: AT „Basic“
U4
QAmm
I1 FG Line FG CB
T1.1 I2 MP
I- 3 ph 51 51 N 50
U-3 ph S 1
I3 CT-3ph 1 U-1 ph S 1
U-3 ph S 2
T1.2 I4
I- PTstar 78 U-1 ph S 2

U1 I- 3 ph
MP U - 3 ph 21
T5 U2 VT-3ph 1
U3 IF IF
SOTF FL

to
I- parl
87 BI CB QA
Ctrl CB
FG PDI BO
SI PDI PDI PDI Int . lk

10 DIGSI 5 - Configure
Version: D_02_Page 35 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines (IEC)
Connect device and primary equipment

 Connect voltage and


current transformers to
function groups in devices
 Connect Trip signal of

Copyright © Siemens AG 2012. All rights reserved.


switching groups to
switching equipment in
bay, e.g. to visually
indicate which CB is
operated
 Manually shift connections
if the automatic layout is
not sufficient

10 DIGSI 5 - Configure
Version: D_02_Page 36 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines (IEC)
Synchronize primary settings with device

 If you have specified the


primary equipment settings
before, then you want to
synchronize them now with

Copyright © Siemens AG 2012. All rights reserved.


the connected devices
 Select a device to synchronize
 Hit “Synchronize” button to
update device settings with
the settings of the primary
equipment.
 This is a manual process to
avoid accidental overriding of
settings.
 Therefore inconsistencies will
be shown by a red border of
the bay if one side changes

10 DIGSI 5 - Configure
Version: D_02_Page 38 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Working with Single-Lines
Using the topology view

 Switch to Topology tree


view using the tab selector
 See and check the

Copyright © Siemens AG 2012. All rights reserved.


connections between
function groups and
primary equipment
 Change names for primary
equipment, also für sub
station and voltage level
 Add and review comments

10 DIGSI 5 - Configure
Version: D_02_Page 40 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Content

Content

 How to handle DIGSI 5

Copyright © Siemens AG 2012. All rights reserved.


 Working with Single Lines
 Adding devices to the project
 Configuring devices
 Adjust settings
 Route information
 Extensibility by function charts
 Create Display pages
 Configure the communication

10 DIGSI 5 - Configure
Version: D_02_Page 41 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Add devices in network view

 Start Devices & Networks


editor with double click on
„Devices & Networks“ in
project tree.

Copyright © Siemens AG 2012. All rights reserved.


 You can also directly open
the Device view by double
clicking on „Hardware &
Protocols“ under a device
 You need the Hardware
catalog to add devices and
hardware extensions

10 DIGSI 5 - Configure
Version: D_02_Page 42 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Add devices in network view

 You need the Hardware


catalog to add devices and
hardware extensions
 Drag and drop devices

Copyright © Siemens AG 2012. All rights reserved.


from Hardware catalog to
editor
 Select appropriate
application template
in the automatically
shown dialog
Drag device
from Hardware
catalog

10 DIGSI 5 - Configure
Version: D_02_Page 43 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Modify hardware of device

 Switch to Device view


 by either double
clicking on a device in

Copyright © Siemens AG 2012. All rights reserved.


Network view
 Or by changing the
view selector to
„Device view“ and
selecting a device in
the toolbar

10 DIGSI 5 - Configure
Version: D_02_Page 44 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Modify hardware of device

 Selecting elements in the


Hardware catalog shows
details in the window in the
lower right-hand corner

Copyright © Siemens AG 2012. All rights reserved.


10 DIGSI 5 - Configure
Version: D_02_Page 45 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Modify hardware in Device view

 Add/Modify
 Current terminals
 Communication

Copyright © Siemens AG 2012. All rights reserved.


modules
 Front panels
 To do so
 Double click on
Drag elements hardware extension
from Hardware places them in first
catalog
available slot
 Drag & Drop elements
from Hardware catalog
to empty slot

10 DIGSI 5 - Configure
Version: D_02_Page 46 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Modify hardware and specify settings in Device view

 By selecting a hardware
element (terminal block,
communication
module/port, front panel…
you can specify settings

Copyright © Siemens AG 2012. All rights reserved.


 Select module and specify
settings and labels for
binary IO
 Select terminal block and
specify meaningful labels
 Select front panel and
specify meaningful labels
for LEDs and F-Keys
 Select communication port
to specify protocols and
protocol settings

10 DIGSI 5 - Configure
Version: D_02_Page 47 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Specify communication settings

 Select the communication


port you want to set up
 E.g. for Ethernet modules,

Copyright © Siemens AG 2012. All rights reserved.


set the properties on page
“Ethernet addresses”:
 IP adress
 Subnet connection
 Create new subnet
…

10 DIGSI 5 - Configure
Version: D_02_Page 48 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Specify communication protocol

 Select the communication


port you want to set up
 E.g. for Ethernet modules,

Copyright © Siemens AG 2012. All rights reserved.


set the protocols supported
channel by channel on
page “Channel x settings”:
 Network protocols
 Communication
protocols
 Settings of the
protocols on subpages

10 DIGSI 5 - Configure
Version: D_02_Page 49 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Add devices to subnets visually

 As mentioned: In the
properties of each
communication port one
can set the subnet the
device is connected to

Copyright © Siemens AG 2012. All rights reserved.


 But: You can also do it
visually
 by connecting the ports
to an existing network
 By connection ports of
multiple devices to
create a new subnet
 Specify a meaningful
subnet name
 See properties of subnet
for a bandwidth estimation.

10 DIGSI 5 - Configure
Version: D_02_Page 50 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Device information – “the business card of the device”

Bild von DI -> Erste seite

 Basic information about the


device
 Type
 Serial number of

Copyright © Siemens AG 2012. All rights reserved.


connected online device
 Possibility to upgrade device
parameter set
 If your device has several
Ethernet interfaces you need
to specify which one is used
for connecting with DIGSI 5.
(see DIGSI 5: Details -
Prepare and establish
connection to the device(s)
 Select language of the device
display

10 DIGSI 5 - Configure
Version: D_02_Page 51 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Configuring devices
Device information - Resource consumption

 Overview over vital


resources used in the
device
 Processor load: If too
many elements are

Copyright © Siemens AG 2012. All rights reserved.


added that can’t be
handled by the device
a list of categories
helps reducing load
 Used and available
function points
 Used CFC ticks and
critical block types
 Use “Refresh” button to
update display when
keeping editor open

10 DIGSI 5 - Configure
Version: D_02_Page 52 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Content

Content

 How to handle DIGSI 5

Copyright © Siemens AG 2012. All rights reserved.


 Working with Single Lines
 Adding devices to the project
 Configuring devices
 Adjust settings
 Route information
 Extensibility by function charts
 Create Display pages
 Configure the communication

10 DIGSI 5 - Configure
Version: D_02_Page 55 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Adjust Settings
Navigate to settings and extend functionality

 Open Settings editor by


selecting a function in
project tree and double
click on that

Copyright © Siemens AG 2012. All rights reserved.


 Navigate through functions
using toolbar buttons

 You can easily add function


blocks of same type using
buttons
 Delete stages using
buttons if they are not fixed
part of the default
configuration

10 DIGSI 5 - Configure
Version: D_02_Page 56 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Adjust Settings
Change settings

 Select setting group for


change
 Available, if multiple
setting groups exist
 Change settings

Copyright © Siemens AG 2012. All rights reserved.


 Invalid settings are
displayed with red
background
 Check tooltips for valid
ranges
 Use arrows beneath
input field to change
value to next valid one
 Some settings don‘t belong
to all setting groups. They
are indicated by icon

10 DIGSI 5 - Configure
Version: D_02_Page 57 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Adjust Settings
Identify settings by unique number

 Turn unique setting


numbers on e.g. to easier
communication with
colleagues

Copyright © Siemens AG 2012. All rights reserved.


10 DIGSI 5 - Configure
Version: D_02_Page 58 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Adjust Settings
Compare setting groups

 To compare two settings


group just select the
comparison group
 Compare values

Copyright © Siemens AG 2012. All rights reserved.


 Differences are
indicated by icon

10 DIGSI 5 - Configure
Version: D_02_Page 59 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Adjust Settings
Synchronize setting groups

 Select a function block by


clicking into gray area
 Choose „Synchronize“

Copyright © Siemens AG 2012. All rights reserved.


 This copies setting values
of the function block from
the comparison group to
setting group for change

10 DIGSI 5 - Configure
Version: D_02_Page 60 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Adjust Settings
Check diagrams that visualize settings

 Many setting groups


contain graphical
representation of stages
and tripping characteristics
 Diagram automatically

Copyright © Siemens AG 2012. All rights reserved.


adjusts to setting changes
 Select stages to be shown
in key of diagram
 Zoom in and out
 Use mouse cursor in the
diagram to get the values
at certain points
 Save picture of diagram or
copy to clipboard for usage
in documentation tools
 Print directly from editor

10 DIGSI 5 - Configure
Version: D_02_Page 61 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Adjust Settings
Setting group handling

 Open Settings > Device


Settings in project tree
 Or directly jump from
settings editor using the
toolbar buttons:

Copyright © Siemens AG 2012. All rights reserved.


 Change number of setting
groups
 Copy settings of a setting
group to another one
 Change active setting
group
 Choose setting group
 Choose selection
criterion
 Change edit mode

10 DIGSI 5 - Configure
Version: D_02_Page 62 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Adjust Settings
Change settings wherever you see function blocks

 You can also change


settings wherever you see
functions
 E.g. in Single-line

Copyright © Siemens AG 2012. All rights reserved.


configuration
 Select function block
 Open Properties area

10 DIGSI 5 - Configure
Version: D_02_Page 63 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Content

Content

 How to handle DIGSI 5

Copyright © Siemens AG 2012. All rights reserved.


 Working with Single Lines
 Adding devices to the project
 Configuring devices
 Adjust settings
 Route information
 Extensibility by function charts
 Create Display pages
 Configure the communication

10 DIGSI 5 - Configure
Version: D_02_Page 64 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Route information
Different tasks – different editors

DIGSI 4
„Masking I/O“
(Configuration
matrix)

Copyright © Siemens AG 2012. All rights reserved.


Information routing Communication mapping
 All routings (except to protocols)  All mappings to protocols

10 DIGSI 5 - Configure
Version: D_02_Page 65 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Route information
Information routing Editor

 Open Information
routing Editor by double
clicking on „Information
routing“ in project tree

Copyright © Siemens AG 2012. All rights reserved.


 Editor is best viewed in
“Maximize mode”
 Rows display signals
and cols possible
routing sources and
destinations.
 Stars indicate that
collapsed rows contain
data
 Right click on cell to
show possible values

10 DIGSI 5 - Configure
Version: D_02_Page 66 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Route information
Short and long display mode

 Double clicking on a
column header toggles
between short and long

Copyright © Siemens AG 2012. All rights reserved.


column mode
 Choose per column
what column mode to
use
 Use toolbar buttons to
toggle all columns
 Short display mode
group e.g. all BIs
 Long: “U”
 Short: “U3, L5”

10 DIGSI 5 - Configure
Version: D_02_Page 67 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Route information
Manage information overload

 Showing everything means


a lot to read
 Use scenario based filters

Copyright © Siemens AG 2012. All rights reserved.


by selecting appropriate
view in drop down list in
toolbar
 Use column filters to
restrict displayed infor-
mation
 Show only signals
containing “Pickup”
 Show only signals
routed to LED 1
 Show only signals
routed to any BI

10 DIGSI 5 - Configure
Version: D_02_Page 68 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Excursion
Filtering in grids

Filter column by selecting an existing Choose (Custom) for complex filters:


value:  (does not) equal
 (does not) begin/end with
 (does not) contain

Copyright © Siemens AG 2012. All rights reserved.


Remove all filters at once

 This filtering functionalities are available in all grids

10 DIGSI 5 - Configure
Version: D_02_Page 69 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Route information
Adding new signals and other functionality

 Drag & drop from


Libraries to hierarchy in
Information routing

Copyright © Siemens AG 2012. All rights reserved.


 FG, FN, FB
 User-defined
function block
 New signals in
function blocks

10 DIGSI 5 - Configure
Version: D_02_Page 70 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Route information
Rename “everything”

 Rename all FG,FN,FB


as well as signals
 Regardless if system- or

Copyright © Siemens AG 2012. All rights reserved.


user defined ones
 Rename in tree
 Or rename in properties
 Here you see also
the original name
 Elements used in
IEC 61850 have an
additional name and
path

10 DIGSI 5 - Configure
Version: D_02_Page 72 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Route information
Comment “everything”

 Inspection remarks
 What needs to be done
 When to review or

Copyright © Siemens AG 2012. All rights reserved.


inspect next time
 Not only in Information
routing but in all editors
and for all elements:
 Add comments to
each element in
Properties tab >
User Information
 Those comments are
saved and exported
to TEAX

10 DIGSI 5 - Configure
Version: D_02_Page 73 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Route information
Change settings quickly

 Select function blocks


(like stages)
 Settings are displayed

Copyright © Siemens AG 2012. All rights reserved.


in properties page
“Settings”
 Only for active setting
group and selected edit
mode (prim, sec. %)
 Change in device
information

10 DIGSI 5 - Configure
Version: D_02_Page 74 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Route information
Change hardware settings of I/O in Information routing

 Select columns of LEDs,


BI, BO, K-Keys
 Change settings like
color, user label … in

Copyright © Siemens AG 2012. All rights reserved.


properties page
“Settings”
 Only works in long
column mode
 Observe tooltip of BIs,
BOs, LEDs…
 They contain location
information
 User defined labels
(check excursion)

10 DIGSI 5 - Configure
Version: D_02_Page 75 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Excursion
User labels makes it easy to find the right things

In Hardware & Protocols editor:  Select housing


 Specify user labels for
 LEDs
 Function keys
 Binary inputs

Copyright © Siemens AG 2012. All rights reserved.


 Binary outputs
 Current and
voltage terminals
 Also available are other
hardware related settings
 LED color
 Threshold of BIs

 All editors working with those elements display user comments

10 DIGSI 5 - Configure
Version: D_02_Page 76 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Route information
Reuse

 Copy and paste


 Function groups, functions, function blocks, signals
 Selected areas in grid to other place in grid
 Selected columns in grid to other columns
 Selected rows, full grid or selected areas of grid to Excel

Copyright © Siemens AG 2012. All rights reserved.


10 DIGSI 5 - Configure
Version: D_02_Page 77 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Content

Content

 How to handle DIGSI 5

Copyright © Siemens AG 2012. All rights reserved.


 Working with Single Lines
 Adding devices to the project
 Configuring devices
 Adjust settings
 Route information
 Extensibility by function charts
 Create Display pictures
 Configure the communication

10 DIGSI 5 - Configure
Version: D_02_Page 78 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extensibility by function charts (CFC)
Create a function chart

 Add new chart by double


clicking on „Add new chart“
underneath „Function
charts“ in project tree.

Copyright © Siemens AG 2012. All rights reserved.


10 DIGSI 5 - Configure
Version: D_02_Page 79 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extensibility by function charts (CFC)
Create a function chart

 Select a name for the chart


 Select the CFC task
 A detailed explanation

Copyright © Siemens AG 2012. All rights reserved.


helps you to select the
right task.

10 DIGSI 5 - Configure
Version: D_02_Page 80 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extensibility by function charts (CFC)
Overcoming the great void of charts

 CFC charts are compatible


to IEC 61131
 Conversion between

Copyright © Siemens AG 2012. All rights reserved.


simple data types happen
automatically
 This simplifies charts a
lot

10 DIGSI 5 - Configure
Version: D_02_Page 81 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extensibility by function charts (CFC)
Add content to your function chart

OR OR

Copyright © Siemens AG 2012. All rights reserved.


Reuse charts or blocks: Build it yourself using the block
library:
Import charts from DIGSI 4
Copy charts from other
devices and projects in DIGSI 5
Copy blocks (rubberband-
selection with mouse) and
paste (keeps connections)

10 DIGSI 5 - Configure
Version: D_02_Page 82 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extensibility by function charts (CFC)
Manually add and connect function blocks

 Select an element in library


 Drag element from library
to editor

Copyright © Siemens AG 2012. All rights reserved.


 Connect blocks by clicking
on port and drag to other
port
 Add constants by selecting
input and typing value
 Copy blocks (rubberband-
selection with mouse) and
Drag element
From library paste
 includes connections

10 DIGSI 5 - Configure
Version: D_02_Page 83 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extensibility by function charts (CFC)
Connect with signals

 Choose signal in Signals


task card
 Drag signal from library to

Copyright © Siemens AG 2012. All rights reserved.


inputs / outputs
 Use the filters of Signal
task card to filter for your
wanted data type („show
me only measured values
(MV)“)
Drag signal to input or output  Choose if you want to see
signals as well-known
margins or „flags“

10 DIGSI 5 - Configure
Version: D_02_Page 84 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extensibility by function charts (CFC)
Extendable blocks

 Some blocks show a green


triangle on bottom
 Those can be extended by

Copyright © Siemens AG 2012. All rights reserved.


the number of inputs
 Open properties of the
block
 Choose page “I/Os”
 Enable display of
additional inputs

10 DIGSI 5 - Configure
Version: D_02_Page 85 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extensibility by function charts (CFC)
Control flow

 Get a good overview over


all connections between
blocks

Copyright © Siemens AG 2012. All rights reserved.


 Change static values of the
inputs easily
 Add new blocks here as
well
 Connect inputs by with
signals from the Signal
task card via drag & drop
 See tracing values while
CFC Tracing and Watching
is activated in a table form

10 DIGSI 5 - Configure
Version: D_02_Page 88 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extensibility by function charts (CFC)
Resource consumption of function charts

 Open Device information


by double clicking on
„Device information“ in
project tree.

Copyright © Siemens AG 2012. All rights reserved.


 Select tab „Resource
consumption“
 Validate resource
consumption of function
charts
 When a limit is exceeded
then an inconsistency
warning indicates that
 Hit refresh when keeping
editor open and updated
list shall be provided

10 DIGSI 5 - Configure
Version: D_02_Page 89 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Content

Content

 How to handle DIGSI 5

Copyright © Siemens AG 2012. All rights reserved.


 Working with Single Lines
 Adding devices to the project
 Configuring devices
 Adjust parameters
 Route information
 Extensibility by function charts
 Create Display pages
 Configure the communication

10 DIGSI 5 - Configure
Version: D_02_Page 90 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Create display pages
Three ways of creating pages

OR OR OR

Copyright © Siemens AG 2012. All rights reserved.


Create from singe-line: Use existing ones: Build it yourself using
the symbol library:

Select bay or  Import from file


device and create  Use the ones in
displays application templ.
Copy elements and  Copy from other
paste in displays device

10 DIGSI 5 - Configure
Version: D_02_Page 91 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Create display pages
The manual approach

 Choose desired symbol


standard (ANSI or IEC) at
OptionsSet Standard
 Select an element in library

Copyright © Siemens AG 2012. All rights reserved.


 Drag element from library
to editor
 Draw lines between
elements by clicking on
port and drag to other port
 Add texts with text tool in
Drag element toolbar
From library
 Add measured values or
dynamic texts with tool in
toolbar
 Rotate elements as
needed

10 DIGSI 5 - Configure
Version: D_02_Page 92 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Create display pages
Display page properties

 Reorder pages by
drag&drop in project tree
 order shown in DIGSI 5

Copyright © Siemens AG 2012. All rights reserved.


will same as in device
 Select default page in
properties
 Change name in headline,
properties or project tree

10 DIGSI 5 - Configure
Version: D_02_Page 93 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Create display pages
Connect with signals

 Elements with (no) signals


assigned are indicated in
different colors
 Choose signal in Signals

Copyright © Siemens AG 2012. All rights reserved.


task card
 Drag signal from library to
symbols or measured
value fields
 Use the filters of Signal
Drag signal to input or output task card to filter for your
wanted data type („show
me only measured values
(MV)“)

10 DIGSI 5 - Configure
Version: D_02_Page 94 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Create display pages
Connect with signals

 If you have IEC 61850


enabled you can drag
signals of other devices in
the same subnet from

Copyright © Siemens AG 2012. All rights reserved.


library to symbols or
measured value fields
 GOOSE connections are
created automatically
 Drag single or double point
Drag signal to input or output indications or measured
values on an empty place
in display to create
dynamic text fields
automatically

10 DIGSI 5 - Configure
Version: D_02_Page 95 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Create display pages
Default controllable symbol

 All display pages are


control pages
 Select default element in

Copyright © Siemens AG 2012. All rights reserved.


properties of symbol
 Will be selected by
default if hitting control
key on device

10 DIGSI 5 - Configure
Version: D_02_Page 96 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Create display pages
Create custom symbol

 Create new symbol using


tool from toolbar

Copyright © Siemens AG 2012. All rights reserved.


10 DIGSI 5 - Configure
Version: D_02_Page 97 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Create display pages
Symbol editor: Create new symbol

 Choose width and height


 Choose static or dynamic
symbol
 Select default state

Copyright © Siemens AG 2012. All rights reserved.


 Add or move red bullets
who indicate ports for
connections
 Draw symbol using the
provided drawing tools
 Closed shapes can be
filled
 Move or resize parts using
the mouse cursor tool
 Hit OK on bottom to take
over symbol to display

10 DIGSI 5 - Configure
Version: D_02_Page 98 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Create display pages
Symbol editor: Reuse symbols

 Drag & Drop symbol from


library to that as starting
point
 Symbol in library is not

Copyright © Siemens AG 2012. All rights reserved.


changed
 Select parts or full symbol
in one state and copy to
other states

10 DIGSI 5 - Configure
Version: D_02_Page 99 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Create display pages
Fault display editor

 Specify information
displayed on device
display in case of faults
 Choose for each line what

Copyright © Siemens AG 2012. All rights reserved.


information to display
 Select the circuit breaker
to show the fault displays
for

10 DIGSI 5 - Configure
Version: D_02_Page 100 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Content

Content

 How to handle DIGSI 5

Copyright © Siemens AG 2012. All rights reserved.


 Working with Single Lines
 Adding devices to the project
 Configuring devices
 Adjust parameters
 Route information
 Extensibility by function charts
 Create Display pages
 Configure the communication

10 DIGSI 5 - Configure
Version: D_02_Page 101 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extend device functionality
Measuring-point routing

 All measuring points


coming by application
templates are ready for
use

Copyright © Siemens AG 2012. All rights reserved.


 Add new measuring points
(1 or 3 phase)
 Added measuring points
need to be connected to
physical terminals

 Select which measuring


point inputs to which
function group
 Connect interfaces
between function groups

10 DIGSI 5 - Configure
Version: D_02_Page 102 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extend device functionality
Function-group interactions

Application templates:
Measuring points are pre-connected Line 1

Copyright © Siemens AG 2012. All rights reserved.


VT 3-phase 1 Voltage 3-phase
with function group interfaces. CT 3-phase 1 Line Current 3-phrase

New function groups added from the


library:
Circuit Breaker 1
The connection between measuring <none> Voltage 3-phase
<none> Current 3-phase
points and function group interfaces <none> Voltage 1-phase

needs to be defined by the user.

10 DIGSI 5 - Configure
Version: D_02_Page 103 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extend device functionality
Function-group interactions

 All Function groups coming


by application templates
are ready for use
 Added Function groups
need to be connected to

Copyright © Siemens AG 2012. All rights reserved.


 Measuring points
 Circuit-breaker groups
 Other function groups
 Protection function
groups

 Select which measuring


point inputs to which
function group
 Connect interfaces
between function groups

10 DIGSI 5 - Configure
Version: D_02_Page 104 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course
Extend device functionality
Function-group interactions

 These connections (measuring point / function group interface) are shown in


 Single-line configurations editor
 Function group connections editor

Copyright © Siemens AG 2012. All rights reserved.


Line 1 Circuit Breaker 1
VT 3-phase 1 Voltage 3-phase VT 3-phase 1 Voltage 3-phase
CT 3-phase 1 Line Current 3-phase CT 3-phase 1 Current 3-phase
<none> Voltage 1-phase

10 DIGSI 5 - Configure
Version: D_02_Page 105 Siemens Power Academy TD
SIPROTEC 5/ DIGSI 5 Basic Course

Potrebbero piacerti anche