Sei sulla pagina 1di 4

Model LCp-200

Vishay BLH
Transducers
Weight Indicator/Controller

FEATURES
• 1 million count resolution, 20 updates per second
• High resolution (16 Bit) analog output
• RS-422/485 communication port with ASCII, Vishay BLH
Digi-System Plus network, or Modbus RTU protocol
• Expansion slot for A-B remote I/O, Modbus Plus, Profibus,
or DeviceNet
• Rate-by-weight (mass flow) operation
• Up To 8 setpoint relay outputs
• Quick-cal set-up
• Dynamic digital process filtering
• Real time system & loop diagnostics

DESCRIPTION APPLICATIONS
LCp-200 Weight/Rate-By-Weight Con- lectable through the front panel keypad.
• Weight and mass flow
trollers are high performance indicators Communication of weight, setpoint values,
with features and options focused on the system status, and diagnostic information measurement with
requirements of process weighing applica- is accomplished using standard protocols setpoint control
tions with local setpoint control. They oper- such as ASCII and Modbus RTU, or spe- • Batch/blend/mix systems
ate with all strain gage type load cells and cial serial interfaces like DeviceNet, Al-
• High value ingredient
interface easily with any PLC, DCS, or PC len-Bradley Remote l/O, Modbus Plus, and
based supervisory control system. Engi- Profibus. processing
neering emphasis has been placed on The LCp-200 Safe-Weigh® Software Sys-
simplicity, reliability, and expandability. tem encompasses over 50 years of Vishay
Standard rate-by-weight operation and out- BLH application expertise. Plug-n-Weigh®
put provides precision mass flow control. quick calibration and setup procedures
Eight relay outputs are available for local save time, money, and even field service
setpoint control, based upon set point val- calls. On-line diagnostics continuously
ues entered through the keypad, or down- monitor system performance and alert
loaded serially from a host device. All relay service personnel to potential problems be-
configuration and logic parameters are se- fore they happen.

CONFIGURATION

Document Number: 12181 vts.us@vishaymg.com www.vishaymg.com


Revision: 26-Apr-05 1
Model LCp-200
Vishay BLH Weight Indicator/Controller
Transducers

Setpoint Control and Communication Interfaces


Setpoint Availability
Precise setpoint control ensures accurate and repeatable
batch process performance. Standard LCp-200 instruments
have eight open collector DC setpoint output signals. Individ-
ual outputs can be configured for main (coarse) or dribble
(fine) operation with in-flight and deadband (hysteresis) com-
pensation for precision valve control. Polarity selection al-
lows ‘open above’ or ‘closed above’ operation of each point.
Tag names may be assigned for front panel or interface iden-
tification.
Optionally, eight solid state, triac type outputs can be
ordered. Each triac output has the same configuration and
parameter selections as the DC signals.
Communications and Interfacing
LCp-200 instruments are designed for fast, easy interfacing
with virtually any PLC or DCS system. LCp-200 instruments
are the first weight/rate system controllers with Schneider
Automation Modbus Plus licensing. As a charter member of
the Allen-Bradley ‘Encompass’ program, Vishay BLH offers
Remote l/O capability in all LCp products. Profibus can be
ordered for communication with Seimens controllers.
For network applications, units can be ordered with our Open collector setpoint outputs interface with PLC I/O cards
Digi-System Plus protocol for communication with an and optional solid state triac relays control process valves
LCp-400 Gate-Weigh controller. directly

OUTLINE DIMENSIONS

www.vishaymg.com vts.us@vishaymg.com Document Number: 12181


2 Revision: 26-Apr-05
Model LCp-200
Transducers
Weight Indicator/Controller Vishay BLH

SPECIFICATIONS

Performance DC Setpoint Outputs - 8 (Standard)


Resolution 1,048,576 total counts Type open collector (current sinking)
Displayed Resolution 700,000 counts Operating Voltage 5 - 35 Vdc
Conversion Speed 50 msec ON Voltage 1.2 Vdc @ 40 mA
Displayed Sensitivity 0.05 µV per count 0.8Vdc @ 1 mA
Noise 0.4 µV per count (min. filt. OFF State Leakage 0.04 µA @ 40 Vdc
setting) Power external supply required
Full Scale Range 3.5 mV/V
AC Setpoint Outputs - 8 (Optional)
Dead Load Range 100% full scale
Type triac
Input impedance 10 m-ohms min
Operating Voltage 12 - 240 Vac
Excitation Voltage 10 Vdc @ 250 mA
AC Frequency 20 - 500 Hz
Linearity ± 0.0015% full scale
ON State Voltage Drop 1.2 Vrms
Software Filter multi-variable up to 10,000 msec
Min - Max Load Current 5mA- 1A
Step Response one conversion
Leakage Current 1mA @ full rated load voltage
Temp Coefficient Zero ± 2ppm/°C
Power external supply required.
Temp Coefficient Span ± 7ppm/°C
Communications (Standard)
Environment
Serial RS-422/485 full or half duplex ASCII, printer,
Operating Temperature -10 to 55° C (15 to 131° F)
Provox, or Modbus protocols
Storage Temperature -20 to 85° C (-5 to 185° F)
odd, even or no parity- selectable
Humidity 5 to 90% rh non-condensing
Baud Rates 300, 1200, 2400, 4800, 9600,
Voltage 117/230 Vac +15% @ 50/60 Hz
or 19200
Power 15 watts max
Addressing 0 - 99
Enclosure
Special Interfaces (Optional)
Dimensions (std) 4.63 x 8.40 x 6.5 in. HWD
DeviceNet to ODVA specification
NEMA 4/4X, 12 (opt) 8.5 x 13.5 x 10.45 in. HWD
Allen-Bradley Remote l/O - 1/4 Logical Rack
Materials Modbus RTU slave
Aluminum Case & Bezel overlay meets 94V-0 rating Modbus Plus peer-to-peer
Profibus slave.
Display
Type high intensity cobalt green Approvals/Certifications
vacuum fluorescent FM (factory Mutual) 3611 (Div 2)
Active Digits 7 digit alpha numeric .59" high CSA C22.2 (all applicable sections)
for weight: 8 digit alpha numeric IEC 801-2 ESD susceptibility, category B
.39" high for status IEC 801-3 radiated electromagnetic field,
cat. A
Analog Output (Optional)
IEC 801-4 conducted line transients, cat. B
Conversion 16 bit D-A
EMI Emissions FCC part 15 subpart B. Class A
Current Selectable 4-20 mA or 0-20 mA - 600 ohm max.
Canadian Dept. of communication.
Remote Digital Inputs (Optically Isolated) Class A
(Contact closure or do logic compatible) EN 5501 Group 1, Class A
Closed (Momentary) logic low IEC 1010-1 Electrical Safety.
Open logic high
Cable Length 100 feet max.

Vishay BLH is continually seeking to improve product quality and performance. Specifications may change accordingly.

VISHAY TRANSDUCERS (VT) SALES OFFICES


VT Americas VT Canada VMG UK VT Sweden VMG Germany VMG France
System Products Toronto Basingstoke Karlskoga Heilbronn Chartres
Norwood, MA
PH: +1-781-298-2200 PH: +1-416-251-2554 PH: +44-125-646-2131 PH: +46-586-630-00 PH: +49-7131-3901-260 PH: +33-2-37-33-31-20
FAX: +1-781-762-3988 FAX: +1-416-251-2690 FAX: +44-125-647-1441 FAX: +46-586-630-99 FAX: +49-7131-3901-2666 FAX: +33-2-37-33-31-29
vts.us@vishaymg.com vt.can@vishaymg.com vt.uk@vishaymg.com vt.se@vishaymg.com vt.de@vishaymg.com vt.fr@vishaymg.com
VT Norway VT Finland VMG Israel VT China VT Taiwan*
System Products System Products Netanya Tianjin Taipei
Oslo Jorvas
PH: +47-22-884090 PH: +358-9-8194-220 PH: +972-9-863-8888 PH: +86-22-2835-3503 PH: +886-2-2696-0168
FAX: +47-22-884099 FAX: +358-9-8194-2211 FAX: +972-9-863-8800 FAX: +86-22-2835-7261 FAX: +886-2-2696-4965
vt.no@vishaymg.com vt.fi@vishaymg.com vt.il@vishaymg.com vt.prc@vishaymg.com vt.roc@vishaymg.com
*Asia except China

Document Number: 12181 vts.us@vishaymg.com www.vishaymg.com


Revision: 26-Apr-05 3
Legal Disclaimer Notice
Vishay

Notice
Specifications of the products displayed herein are subject to change without notice. Vishay Intertechnology, Inc.,
or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies.

Information contained herein is intended to provide a product description only. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's
terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express
or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness
for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right.

The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify Vishay for any damages resulting from such improper use or sale.

Document Number: 91000 www.vishay.com


Revision: 08-Apr-05 1