Sei sulla pagina 1di 5

Company Image - ENZYMATIC Ltd

Our company has been accomplishing the agricultural, environmental protection investments for ten
years supported by the European Union. During the realization of these investments we strive to offer a
full service containing the planning activities for the entire scale of the projects.

The main activity of our company is the recultivation, reconstruction and modernization of animal
plants taking into consideration the legal and technical standards of the European Union. Our other
main activity is the bacterial treatment of manure.

We have all the experiences, references and professional sources in the fields mentioned above.

The ambition of Enzymatic Ltd is to build long term connection with its partners. The co-operation - in
case of need - covers the thinking together, the acceptance of our partners' ideas and proposals that are
to be built in our strategy.

The main activity of our firm is the modernization and reconstruction of the environmental
protection in animal plants.

Our services:

- renovation and reconstruction of stables into lagoon system


- building new stables
- laying pressure and gravitation lines
- building of new manure tanks with 2mm HDPE foil
- reconstruction of manure tanks
- complete recultivation
- building of new bedding manure tanks
- renovation of bedding manure tanks
- complete technological mechanization

Further services:
- complete planning
- making of applications, tenders

Quality assurance

In order to get customer satisfaction we operate a quality control system according to MSZ EN ISO
9001:2001 standard. The continuous development of this system is our basic obligation.
The review of our products:
ENZYMATIC - EWD

- eliminates creation of ammonia gas, the hydrogen-sulphide and other gases in animal plants,
- creates probiotic environment for isolated plants,
- creates quick regeneration,
- provide natural odour control in the environment of animal plants,
- accelerate the reconstruction of waste water,
- increases the capacity of waste treatment systems,
- reduces BOD,COD and SS values at the outlet of animal plants,
- lower costs according to the relative manure volume,
- easy treatment, no need for special preparation, wide range of usage / for all systems
mentioned above/
- eliminates settling and blockage in case of litter free systems,
- environmental friendly and can be used in a wide range by its bio -degrading components,
- reduces water consumption because it dissolves the solid components.

Directions for use and application rate:

- For the initial treatment of any wastewater system you need four times more quantity of
ENZYMATIC _ EWD according to normal preventing usage. It is a general rule that you need
2/g/m3 of ENZYMATIC- EWD to normal daily preventive maintenance depending on the
total weight of the wastewater. The flood rate can also influence the quantity of
ENZYMATIC-EWD needed to normal preventive treatment. Measure the weight of the
organic wastewater flowing through the treatment system and add 5-10 g/m3 ENZYMATIC-
EWD according to the weight. In case of normal preventive treatment the place of application
should be chosen where the water remains for the longest period of time. The material should
be used within 30 minutes after mixing.

The presence of separately concentrated heavy metals like mercury, chrome and inorganic cyanide can
influence the biological growth negatively.
ENZYMATIC -BACTI

- reduces bad odour in the environment of pipe lines and fat traps,
- liquefies organic structures in slow flowing pipe lines,
- eliminates blockages
- provide easy flow in pipe lines,
- recreates beneficial bacteria in pipelines and in fat traps,
- especially economical usage,
- accelerates liquefying processes,
- no solid settings, environmental friendly and safe usage / safer than the usage of raw
chemicals /

Directions for use and application rate:

The treatment programme of the pipelines of constructions is very simple, but you should always keep
the directions.
The first step is to map the entire pipeline of the structure including floor pipes as well.
The treatment program begins at the end of the day when the ENZYMATIC-BACTI is put in every pi
pe .
Solve 100 gr. of ENZYMATIC-BACTI formula in 20 l. hand warm water and mix it carefully. The
solution should be poured into every junction and fat traps in the territory of the asset. Repeat it daily
until the free flow is getting possible.
The ENZYMATIC-BACTI should be used at the end of the day / after closing hours /.
In case of more levels /floors/ it is recommended to begin on the lower levels and then to continue on
the upper ones.
In case of fat traps the first treatment should be 4 times more quantity than that of the normal
treatment.
ENZYMATIC-BIO

- reduces BOD, COD and SS values at the outlet of wastewater treatment systems in food
industry,
- short reconstruction period,
- helps to remove foam at the end cleaner, helps the degrading of different waste components,
- increases the capacity of wastewater systems,
- reduces toxic influences,
- strengthens odour control through natural acid oxidation,
- environmental friendly, bio-degrader component for wide usage

Directions for use and application rate:

For the initial use of any wastewater system you need four times more of ENZYMATIC-BIO than the
quantity needed for normal preventive treatment. It is a general rule that for the normal daily
preventive maintenance you need 2gr./m3 of ENZYMATIC-BIO according to the total weight of the
wastewater. The flow direction also influences the quantity of ENZYMATIC-BIO to be used for the
normal preventive treatment. Measure the weight of the organic wastewater flowing through the
treatment system and add 5-10 gr./m3 of ENZYMATIC-BIO according to the weight. In the normal
preventive programme the place should be chosen where the wastewater can remain for the longest
period. Differently concentrated heavy metals like mercury, chrome and inorganic cyanides can
influence the biological growth negatively.
ENZYMATIC-BAC

- reduces BOD,COD and SS values at the end of drainages in industrial wastewater treatment
systems,
- short reconstruction period, helps the setting of foam to eliminate the gathering of waste,
- helps to degrade the contamination of different components,
- increases the capacity of municipial and industrial wastewater treatment systems,
- eliminates toxic influence,
- strengthens the stability of municipial and industrial wastewater systems
- by natural oxidation strengthens odour control,
- environmental friendly, bio degrader for wide range of use.

Directions for use and application rate:

For the initial use of any wastewater system, you need four times more of ENZYMATIC-BAC than
the quantity needed for the normal daily preventive treatment. It is a general rule that you need
2gr./m3 of ENZYMATIC -BAC for the normal preventive use according to the total weight.
The direction of the flow can also influence the quantity of ENZYMATIC-BAC needed for the normal
preventive use. Measure the weight of the organic wastewater flowing through the treatment system
and add 5-10 gr./m3 ENZYMATIC-BAC according to the weight. The place of the normal daily
preventive programme should be chosen where the wastewater remains for the longest period of time.
The given formula must be added within 30 minutes. It is very important that the ENZYMATIC-BAC
should be applied as it is written in the directions

Contact:
AMP IDEAL
Velika 60 Sajan
053 809 59 04

Potrebbero piacerti anche