Sei sulla pagina 1di 53

Nokia 2G/3G Swap-Out

Rehoming
TRX Upgrade
3rd - 4th Carrier Upgrade

BOTA-MAI (Access)
27.6.2017
Internal Use – Interner Gebrauch
01 > Intro
02 > Tools
03 > Preps
04 > HW Swap-Out 2G
05 > Troubleshooting
06 > HW Swap-Out 3G
07 > Troubleshooting
08 > Swap-Out Live
09 > Recap

2 Internal Use – Interner Gebrauch


01 Intro

Internal Use – Interner Gebrauch


BOTA-MAI PAC
Back Office Transport Access
BSC-RNC Modification
Mobile Access Integration

Projects

Upgrades

Rehoming

089/2442-80410 (Hotline)

4 Internal Use – Interner Gebrauch


02 Tools

Internal Use – Interner Gebrauch


CCM - Databank
NE configuration data for BSC/RNC

10.127.4.91:8079 10.127.4.90:8079

Server 2
Server 1

6 Internal Use – Interner Gebrauch


7 Internal Use – Interner Gebrauch
8 Internal Use – Interner Gebrauch
9 Internal Use – Interner Gebrauch
Finderella (unofficial)

10 Internal Use – Interner Gebrauch


03 PREP

Internal Use – Interner Gebrauch


CRQ Search

CRQ ID

CI ID

Date

Rehoming?

12 Internal Use – Interner Gebrauch


NETsite – Data Check

Projects

Project ID (!)

„Kapazitäten“

13 Internal Use – Interner Gebrauch


Preparation CCM Data -> 2 Days in Advance (!)

Software Release

Region

Filter

Wirkdaten (inconsistencies)

Plandaten

Delta

14 Internal Use – Interner Gebrauch


Wirkimport Inconsistencies

• Two same NEs (old and new) can‘t have


the same administrative state (locked)
• When rehoming, always lock old cells
before your start on the new controller
• When you finish your rehoming, do not
leave both in a locked or both unlocked
state

15 Internal Use – Interner Gebrauch


Configuration Data Availability

Rehoming?

Compare (NETSite, MML)

BCF Type! (MR10 – subtype 3)

16 Internal Use – Interner Gebrauch


04 HW Swap-Out 2G

Internal Use – Interner Gebrauch


2G Swap-Out
(Rehoming/TRX Upgrade)

Delete Old
Preparation Configuration Import New
(CCM Filter - CRQ Alarm Check Alarm Check CRQ Set Status in
(Back-up Plan Configuration
NCM BSTRX „Implement“ + Block NE + Unblock NE „Closed“ NETsite
+ BSC on BSC
2G )
Upload)

18 Internal Use – Interner Gebrauch


On the Day - First off

Export File

19 Internal Use – Interner Gebrauch


Look up Corresponding CRQ

CRQ ID

Status -> „Implement“

Outage (SA Zeit) - Started

Comment Included

20 Internal Use – Interner Gebrauch


Alarm check
1. ZEEI:BCF=2;
List current configuration
(compare with new data ->
TRX upgrade?)

21 Internal Use – Interner Gebrauch


Block NE

ZEQS:BTS=5:L:FHO,150;
• Customer friendly FHO
(forced handover)

22 Internal Use – Interner Gebrauch


Delete BSC Configuration – Create a Plan (CM Editor)
1. Create plan and name it
(306301438_delete)
2. Locate your BSC (C-Number)
3. Locate your BS
4. Right click -> Delete
5. Select LAPD + DAP as well (under
TRX)
6. Right click –> Delete
7. Untick all objects and check the
content of your delete plan(CTRL-M)
8. When rehoming, wait until you
imported the new config on the
new BSC
23 Internal Use – Interner Gebrauch
Activation of a Delete Plan (Operations Manager)

1. Set „approved“
2. Tick off „create backup plan“
3. „Prepare plan“ ticked off
4. Start
5. Finished x Failed?
6. Check if deleted (MML)
7. BSC Upload

24 Internal Use – Interner Gebrauch


BSC Upload (Operations Manager)

• Upload BSC
• Updates NetAct database
• backup plan (!)

25 Internal Use – Interner Gebrauch


Import File - New Configuration (Opereations Manager)

1. Go to „File“ - > import


2. Tick off „internal values“
3. Select your file
4. „OK“
5. „Start“
6. Look out for errors

26 Internal Use – Interner Gebrauch


Activation of a Create Plan (new configuration)

1. Is the old NE deleted?


2. Activation
3. Look out for activation errors
4. Finished x Failed?

27 Internal Use – Interner Gebrauch


When Rehoming – Unblock Signalling
Unlock
ZDTC:U0060:WO:;
ZDTI:::PCM=112;
ZDTC:T1060:WO:;
ZDTC:T2060:WO:;
ZDTC:T5060:WO:;
ZDTC:T6060:WO:;
ZDTC:T9060:WO:;
ZDTC:TA060:WO:;

28 Internal Use – Interner Gebrauch


NE Check Same BSC (on site finished)

1. ZEEI:BCF=60;
2. OMU Sig - > WO
3. DAP Pool
4. Branching

29 Internal Use – Interner Gebrauch


Branching – BTS Manager

Commissioning
1. Change settings manually
2. Do not change HW settings

• Timeslots (TRX upgrade?)


• Signalling
• DAP Pool

30 Internal Use – Interner Gebrauch


Unblock NE – check Alarms

• OMU Sig. - WO
• Unblock TRX – BTS –
BCF
• Check active calls
• Check current alarms

31 Internal Use – Interner Gebrauch


Close CRQ

CRQ ID

CI ID

Comment

Outage Timestamp

Status - > CLOSED

32 Internal Use – Interner Gebrauch


Set status in NETsite

CI ID

Swap-Out
Project ID

Status 290

33 Internal Use – Interner Gebrauch


05 Troubleshooting 2G

Internal Use – Interner Gebrauch


Troubleshooting – Activation Error -> Feedback
089/2442-80410 (Hotline)

• First disturbance interrupts the whole


process
• See the „Details“ for explanation
• Locate the managed object
• Adjust your plan in CM Editor or modify the
object per MML

35 Internal Use – Interner Gebrauch


Troubleshooting – Activation Error

36 Internal Use – Interner Gebrauch


Troubleshooting - DAP Pool

Check DAP: ZESI:ID=60;


Delete DAP: ZESG:ID=60;
Create DAP:
ZESE:ID=60:CRCT= 112-21,SIZE=4,PSEI=10700;

PCU Pool Frame Relay


ZFXL:PSEI=0&&99; ZFXO:NSEI=0&&65535;

37 Internal Use – Interner Gebrauch


06 HW Swap-Out 3G

Internal Use – Interner Gebrauch


3G Swap-Out
(Rehoming + 3rd or 4th Carrier Upgrade )

Save a back up
When Rehoming
commissioning
Preparaton -> delete unused
file and then
(Commissioning CRQ in data on the Set Status in
Block NE import new Unblock NE Check NE CRQ to „Closed“
File – Share „Implement“ original RNC! Netsite
commissioning
Point) Administrative
file in WBTS - >
state
activate

39 Internal Use – Interner Gebrauch


Commissioning File (Share Point)

1. Share point
2. Nokia Commissioning 3G Blau
3. PAC (current period)
4. Region
5. Download
6. Import into WBTS (WBTS Manager)
(The file includes carrier upgrades as well as modification of IP
addresses necessary for rehoming)

40 Internal Use – Interner Gebrauch


Block NE

• Mark all the cells of the NB -> LOCK


• Absolutely vital when rehoming (!)
• Reason? Wirkimport Inconsistencies

41 Internal Use – Interner Gebrauch


Save a Back-Up File

42 Internal Use – Interner Gebrauch


Commissioning File Import (WBTS)
Step 1

1. BTS Part only


2. Template
3. Next

43 Internal Use – Interner Gebrauch


Commissioning File – Import (WBTS)
Step 2

• Finalize
• Unblock Cells
• Check NE
• Check RNC

44 Internal Use – Interner Gebrauch


When Rehoming -> Delete Unused Data on the Old RNC

1. Create plan and name it


2. Locate your NE
3. Right click WBTS and IPNB
- > Delete

45 Internal Use – Interner Gebrauch


07 Troubleshooting 3G

Internal Use – Interner Gebrauch


Troubleshooting – Check IP Route
Check IP Routes on mcRNCs: Check IP Routes on IPA-RNCs:

show networking ipbr ipbr-id <wbts-id> ZQRL;

show networking ipro ipro-id <wbts-id> ZQRB:NPGEP:;

ZQKB:NPGEP:;

If there is no route please contact BO GU-Support-Hotline or


send a mail to If there is no route look in the
ovidiu.muntean.external@telefonica.com or maria- „NSN_3G_BO_Integration_AA_(GU)_v3.6“ or BO GU-Support-
lucia.balta.external@telefonica.com Hotline or send a mail to
ovidiu.muntean.external@telefonica.com or maria-
lucia.balta.external@telefonica.com

47 Internal Use – Interner Gebrauch


BFD Session
It has been decided that BFD sessions will be soon all deactivated. One of the reasons behind is, we have other alarms
indicating the same problem (a connection between WBTS and RNC is interrupted).

At the moment, there is a mix between RNCs, which have the BFD session still activated and RNCs, where it already was
deactivated.

What it means is, the BFD Session after rehoming might show BFD session down. If that is the case, please follow this:

• Check if the BFD session for the WBTS is in an active or disabled state on the RNC (BFD Session ID = WBTS ID)
• If it‘s in fact is disabled – deactivate it on the WBTS as well (alarm disappears -> the cells however are still on air)
• If the BFD session is in an active mode on the RNC, the BFD session on the WBTS has to also be set as „in use“.
• If you are unsure contact GU Hotline 089/2442-80410

See next 2 slide for further information

48 Internal Use – Interner Gebrauch


BFD Session – RNC Check (mcRNC x IPA)
mcRNC - BFD Session admin state: Disabled ipaRNC – BFD Session admin state: ADMIN DOWN

Check status

49 Internal Use – Interner Gebrauch


BFD Session – WBTS Deactivation

On Off

50 Internal Use – Interner Gebrauch


07 Swap-Out live

Internal Use – Interner Gebrauch


08 Recap

Internal Use – Interner Gebrauch

Potrebbero piacerti anche