Sei sulla pagina 1di 60

ZTE SDR UniRAN Base Station

Introduction


Contents

 ZTE SDR UniRAN Base Station Overview


 ZXSDR B8200 Product Description
 GUL RRUs Product Description
 ZXSDR BS8900A Product Description

2
ZTE FDD GUL SDR Base Station Overview
Macro

B8200 B8901B

Component – BBU

RSU RRU AAU


BS8900B BS8900A BS8908 BS8800 BS8906 BS8700
Component – RF Module
Small Cell
BBU BBU

pBridg
e pBridge
BS8912 BS8922
pBridg
Cable e

pBridg pRRU
Fiber e

BS8112 BS8102 QCell pBridge


Components
© ZTE All rights reserved 3
ZTE FDD GUL SDR Base Station Family
Baseband Unit Macro BS Compact BS Small Cell Multi-Mode

Full Bandwidth
QCell
Indoor B8200
Outdoor BS8908 Ultra Broad Band
BS8912BS8922

R8119/R8129+PB1120A Miniaturization
R8108+PB1000
Pad BBU Outdoor Indoor
BS8900A BS8900B BS8800 MA1020
Outdoor Outdoor BS8906 BS8112
BS8102 High Power
B8901B

High Efficiency
RSU RRU AAU

1T 2T 1T 2T 3T 4T AAU Multi-PA

High Integration

RSU40 RSU82 R8861 R8862/A R8872A R8852/E


Innovation

Pad RRU iMacro


R8402/ A8602 A8290 A8292A
RSU60E RSU72 R8881 R8882 R8892E/N R8412 R8864 R8854/D
© ZTE All rights reserved 4
ZTE FDD GUL SDR Base Station Introduction
Type
Type Scenario
Scenario BS
BS Feature & Application
Feature & Application Component
Component Solution
Solution

Large capacity; All IP structure; High reliability;


Indoor BS8800 B8200+RSU GUL
Rich interfaces; Smooth evolution; Used for macro coverage

All-in-one solution in one rack; 2–8 hours battery backup; Large


BS8900B B8200+RSU GUL
capacity; Smooth evolution; Used for macro coverage

M Modularized design; All in one outdoor site solution; 2–8 hours


BS8900A
A battery backup; Large capacity; Smooth evolution; Used for B8200+RSU GUL
macro coverage
C
Macro
Outdoor
R BS8906
Strong adaptation to tough environments; Fast deployment;
B8200+RSU GUL/GU
Used for complementary coverage
O
Low power consumption; Flexible networking; Compact design;
BS8908 Integrated G
Natural cooling; Used for GSM rural area or blind area

Small and light, easy for installation; Fast deployment; Flexible


Distributed B8200+RRU
networking; Saving project cost and decreasing construction
Indoor/Outdo BS8700 B8200+AAU GUL
time; Used when the site acquisition is difficult or room rental is
or B8901B+RRU
expensive

BS8912/BS L/U mode sharing the same hardware; Supporting 2*2 MIMO;
Outdoor Integrated U/L
8922 Small volume, large capacity; Used for hot spots or blind areas
Small
Small
Cell
Cell Quite Cute; Quad Band; Quick Deployment; Quality Assurance; BBU+pBridge+
Indoor QCell UL
Used for indoor coverage, supporting high U/L data throughput pRRU

© ZTE All rights reserved 5


ZTE FDD GUL SDR Base Station Application
Scenarios
 Large capacity
 Outdoor all in one
solution Indoor Macro BS
 U/L high data throughput Macro Coverage
 Simple deployment
Micro BS
 Low cost
Hot Spots
& Blind Areas
CBD
Outdoor Macro BS
QCell
Macro Coverage Indoor
Coverage

Buildings

 Medium capacity
 Fast installation  Large capacity
 Coordination with  Indoor machine
Macro room is available
Parks Buildings

© ZTE All rights reserved 6


Contents

 ZTE SDR UniRAN Base Station Overview


 ZXSDR B8200 Product Description
 GUL RRUs Product Description
 ZXSDR BS8900A Product Description

7
Distributed BS
BS R RS B
Base Station

Hardware Name Radio Resource Unit


BS.XXX
Hardware Name Radio System Unit
R.XXX Base Band Unit
Hardware Name
RS.XXX
Hardware Name
RRU B.XXX
B8200
CPRI

BS8900A BS8700

BC8910A

Integrated outdoor solution without battery



 With BC8910A cabinet CPRI
 AC/DC power supply Fiber

 Built-in RRU power supply


 1 BBU with maximum 8U reservation for 3 rd party
equip

© ZTE All rights reserved 8


Base Band Unit — ZXSDR B8200
Performance Index
Based on Unified MicroTCA Platform
Capacity:
 Depends on CC/BP configuration
15 PM 4 8 16 Base Band Processing Capability:
3 7 F
14 PM
 Depends on CC/BP configuration
88.4m 2 6 A
m 1 5 N 197mm Data Processing Capability:
13 SA
 Downlink: Depends on CC/BP
482.6m
m configuration
 Uplink: Depends on CC/BP configuration
Typical Power Consumption (TPC) :
 Supports multi-mode  Large capacity
 UMTS: 80W (6CSs), 120W (12 CSs)
 All-IP structure  Various interfaces
 Low power consumption  Smooth evolution  GSM: 50W (12 TRXs), 60W (24 TRXs)
Power Supply: -48V DC
Temperature Range: -20℃ to + 55℃
 Interface Index
 Abis/Iub interface:
 4 E1/T1
 1 GE optical or 1 GE/FE electrical Physical Index
 BBU to RRU interface: Volume: 88.4 mm*482.6 mm*197 mm (H*W*D)
 12 CPRI interfaces Weight: 8.75 kg (full configuration)

© ZTE All rights reserved 9


ZXSDR B8200 Highlights
19 inch  Large capacity and
modularized design, easy to

2U expand
 Baseband resources are
pooled among multiple BP
boards
 All IP structure, supporting
future smooth evolution
 Various interfaces, supporting
flexible networking
 High reliability , supporting
1+1 or load sharing backup
 Low power consumption,
energy saving
 Smooth evolution, HSPA+/LTE
achieved by minimal
hardware change

© ZTE All rights reserved 10


ZXSDR B8200 Boards (#1/2)


PM FS

FAM
Modularized High
Design BP
Reliability
SA CC

 Control & Clock Board (CC): Implement the controlling & management function
of the baseband unit, and provide one IP connection for Abis/Iub interface
(GE/FE self adaptation, electrical or optical) and system clock.
 Fabric Switch Board (FS): Implement the switching function, support 6 CPRIs,
used for connection with RRU. Sometimes optional.
 GSM/UMTS/LTE Baseband Processing Board (BP)
 Baseband Processing Board Type N2 (BPN2)

© ZTE All rights reserved 11


ZXSDR B8200 Boards (#2/2)

PM FS

FAM
Modularized High
Design BP
Reliability
SA CC

 Fan Array Module (FAM): On the side of the BBU frame, used for heat
dissipation.
 Power Module Board (PM): -48V DC power supply module for B8200.
 Site Alarm Board (SA): Provide 4 E1/T1, 1 RS485/232 and 16 dry contacts (14
inputs, 2 bi-directional interfaces) *

*external\internal alarms, sends to CC then to OMM of RNC/BSC

© ZTE All rights reserved 12


ZXSDR B8200 Boards & Performance


PM FS

FAM
Modularized High
Design BP
Reliability
SA CC

Module Name Shared by GUL Min/Max Configuration Comments

CC Board Y 1/2 B8200 control and clock

FS Board Y 1/2 RRU/RSU aggregation

BP Board Separate/Y 1/5 Slots for GSM, UMTS & LTE

SA Board Y 1/1 Dry contacts & E1&T1

PM Y 1/2 Power supply

FAM Y 1/1 Internal fans for cooling

 GSM/UMTS/LTE share the main boards such as control boards


 Configure the baseband boards according to the capacity of GSM/UMTS/LTE.

© ZTE All rights reserved 13


ZXSDR B8200 Boards & Performance

 Boards and Modules


 The ZXSDR B8200 is a baseband unit designed on the basis of the MicroTCA
architecture. MicroTCA, also known as μTCA, is based on the PICMG standard.
It originates from ATCA and improves upon ATCA.
 In accordance with the MicroTCA specification, the ZXSDR B8200 modules
have two height types: full height (Double Modules) and half height (Single
Module).

Corresponding
Name Height (mm)
Board/Module
Full height (Double
148.8 CC/FS
Modules)

Half height (Single Module) 73.8 PM/SA/FAM

© ZTE All rights reserved 14


Control & Clock (CC) Board Introduction

Interface Name Description


Ethernet interface between BTS and BSC/RNC, self-adaptive 10M/100M/1000M
ETH0
electrical interface.
Ethernet interface used for cascading, debugging or local maintenance, adapting
DEBUG/CAS/LMT
interface of 10M/100M/1000M.
Ethernet interface between BTS and BSC/RNC, self-adaptive 100M/1000M optical
TX/RX
interface.
External communication port, connected to external receiver for clock
EXT
synchronization or cascading.

REF Connected to GPS signal interface, or 2 MHz BITS signal interface.

USB Used for software upgrade (only for CC16)

 GPS system clock & BITS clock & SyncE clock & interface recovery clock
 Abis/Iub interface protocol processing
 Ethernet switch function, providing switch plan for signaling and media stream
 System management
© ZTE All rights reserved 15
CCE1 (1/4)

 The CC module performs baseband unit control management


and Ethernet switching, and provides the system clock. It
provides the following functions:
 Implements the Ethernet switching function, switching service data flow and
control data flow within the system.
 Implements Abis/Iub/S1/X2 interface protocol processing.
 Monitors the control and maintenance of the base station system, and
provides the LMT interface.
 Performs software version management and programmable device
management, and supports local and remote software upgrade.
 Monitors the operating status of each board in the system.

© ZTE All rights reserved 16


CCE1 (2/4)

 Synchronizes with external reference clocks, including the IEEE1588 clock,


GPS clock, and the clocks (2 Mbits and 2 MHz) provided by the BITS.
 Generates and transmits clock information as needed.
 Provides GPS signal interfaces and manages GPS receivers.
 Provides the unified reference clock for system operation and maintenance.
The real-time clock can be calibrated.
 Reads hardware management information, including rack number, back-end
type, slot number, board type, board version, and board function
configuration information.
 Supports active/standby switchover.
 Provides maintenance functions for the Micro TCA module.
 Can be used in different bands and GUL multi mode.

© ZTE All rights reserved 17


CCE1 (3/4)
CC Performance Specifications

CC Type CCE1

GUL Multi-Mode
System
And LTE single mode

UMTS CNBAP processing


3000/s
capability

10800 users connected through


LTE processing capability RRC: 1.8 Gbps (uplink), 3.6 Gbps
(downlink)

© ZTE All rights reserved 18


CCE1(4/4)

 CCE1:

 Note:
 In actual applications, a label is pasted on each CC panel to indicate the CC
type. The label is omitted in the above figures.

Technology Transmission Board Description

2*10GE optical Ethernet port+3GE/FE


GUL CCE1
electrical Ethernet port

© ZTE All rights reserved 19


Baseband Processing (BPN2)

 The BPN2 is a multi-mode baseband processing board.


 It integrates the functions for GSM, UMTS or LTE single-mode baseband
board
 It can operate in single-mode or multi-mode.
 TX0 RX0 through TX5 RX5
 Has 6 pairs of CPRI optical interfaces, used to connect to RRUs/RSUs.
 no need of FS card for some configurations
© ZTE All rights reserved 20
BPN2 Performance Specifications
- BPN2
CPRI interface 6 pairs
GSM 72 TRXs
12 carriers (1024 CEs)
UMTS
DL 518.4Mbps/UL 138Mbps
12 LTE cells
LTE 7200 RRC connected users
DL 1200Mbps/UL 600Mbps
12 GSM TRXs + 12 UMTS carriers (768 CEs)
GSM/UMTS dual-mode 24 GSM TRXs + 9 UMTS carriers (640 CEs)
36 GSM TRXs + 6 UMTS carriers (512 CEs)
GSM/LTE dual-mode 36 GSM TRXs + 6 LTE cells

UMTS/LTE dual-mode 6 UMTS carriers (512 CEs) + 6 LTE cells

GSM/UMTS/LTE multi- 12 GSM TRXs + 6 UMTS carriers (256 CEs) + 6 LTE cells
mode 24 GSM TRXs + 3 UMTS carriers (128 CEs) + 6 LTE cells

© ZTE All rights reserved 21


Fabric Switch (FS) Board Introduction


Description

Six pairs of optical


TX0 RX0
interfaces or electrical
FS5A through TX5
interfaces, used to connect
RX5
the BBU to RRUs.
10 GE interface, used for
ETH (for CRO baseband data
only) communication among
Fabric Switch Module BBU shelves.

 Baseband IQ data switching and MUX & DE-


MUX
 Baseband IQ data exchange
 Provide interfaces between RRU and BBU

Highlights
Shared among different access technologies: GSM, UMTS and LTE
Can be used in different bands
 No influence on fiber connection when upgrading network mode comparing with other vendor
solution

© ZTE All rights reserved 22


Fabric Switch (FS) Board Types

FS Board Type FS5a CR0


GSM/UMTS/LTE (single LTE mode (when Cloud
Wireless system
mode or multi-mode) Radio is required)

Maximum number of cells


supported when FS is
12 12
operating with a single UMTS
baseband processing board

Maximum number of cells


supported when FS is
operating with UMTS 60 60
baseband processing boards
in a shelf

1.2288/2.4576/ 1.2288/2.4576/ 3.072/6.144/


CPRI interface rate (Gbps)
3.072/6.144/9.8304 9.8304

© ZTE All rights reserved 23


Site Alarm Board

Interface
Description
Name
4 E1/T1 interfaces and 14 input +2 output dry contacts
- 1 RS485interface,
1RS232 interface,

Site Alarm Board/Site Alarm Extension Board provides:


 Fan rate control
 Site alarm monitoring and interface lightning protection for the rack
SA Cable
 A-- Connected to SA board
 B1--DB-44, providing 4*E1/T1
 B2--DB-9, RS232/RS485 connector
 B3--DB-25, dry-contact connector
 B4--Grounding cable

© ZTE All rights reserved 24


Site Alarm (SA) Board
 The SA board provides the following functions:
 Provides E1/T1 transmission for the Abis/Iub interface.
 Performs alarm monitoring and rotating speed control for fans.
 Performs signal monitoring and interface lightning protection for the
cabinet.

© ZTE All rights reserved 25


Power Module (PM) Board Introduction

Interface Name Description


MON Debugging interface, RS232 interface
-48V/-48VRTN -48V input

ON/OFF Power switch, turning on/off 12V power to/from BBU

Power Module
 16 internal interfaces for +12V, +13V and +28V load power
 16 internal interfaces for +3.3V management power
 Measurement and protection of inputing over-voltage/under-voltage
 Output over-current protection and load power management

© ZTE All rights reserved 26


Power Module (PM) Board Introduction

 PM is the power module. PM5 configuration support new high


power consumption boards, shown in the following figure.
 PM5 Panel

Interface Name Interface Name


MON Debugging interface, RS232 interface
-48V/-48VRTN -48V input

© ZTE All rights reserved 27


PM: Power Module configuration

 Two PM5 are required when 4


BPN2 baseband processing
boards are configured.
 Two PMs are required when two
power supplies are operating in
active/standby mode.

© ZTE All rights reserved 28


FAM: FAN Module

 FAM is fan array module.


 The FAM has the follows functions:
 Monitors and controls system temperature;
 Monitors, controls, and reports the fan state.

© ZTE All rights reserved 29


Flexible Networking Capability

 Star topology Chain topology


RRU
RRU
B8200
B8200

E1/T1/GE/FE
RNC/BSC
E1/T1/GE/FE

Supporting 4 levels cascading


Supporting multi RRU in one cell
Farthest reaching 40 km with 4
levels

 ZTE provides flexible networking for distributed site such as star, chain, loop and
hybrid topology to meet demands from customers.

© ZTE All rights reserved 30


GU Transmission Type

 GSM Transmission Type


Item Transmission Type
Abis interface(E1) IP over CSTM-1 (5% Traffic model)
Abis interface (IP) IP over Optical GE
A interface TDM over CSTM-1
Gb interface IP over Optical GE

 UMTS Transmission Type

Item Transmission Type Comments

All RNCs will be considered


Iub interface 10 GE, Optical optical 10 GE interface.
All RNCs will be considered
Iu+Iur interface 10 GE, Optical optical 10 GE interface.

© ZTE All rights reserved 31


Flexible Networking Capability

 In chain network or star network, max 4 level in 40km is


supported.
 In cascading, the following conditions have to be satisfied:
 For CPRI=1.25G interface:N+6*M≤24
 For CPRI=2.5G interface: N+6*M≤48

 Meanwhile, N=total number of TRXs;M=total number of CSs

© ZTE All rights reserved 32


Contents

 ZTE SDR UniRAN Base Station Overview


 ZXSDR B8200 Product Description
 GUL RRUs Product Description
 ZXSDR BS8900A Product Description

33
Remote Radio Unit — ZXSDR R8882
L GU GL UL

23L/23K PA PA PA PA
g
Capacity 1*20M Cell
2*4TRXs+1*10M Cell@900M
2*40W@DD/2600MHz; Capacity 2*4TRXs+1*20M Cell@1800M
Max TOC 2Cs MIMO+1*20M Cell@2100M
2*60W@others
2T2R@AP700/DD Max TOC 2*60 W
TxRx 2T4R@810/2600MHz/AW TxRx 2T4R
S
Typical Power
Typical Power 215W(2600MHz) 300W (G S44+U S11, 900MHz)
Consumption
Consumption 185W(700MHz)
Interfaces 2*2.5G/6Gbps CPRI interfaces
Interfaces 2*6Gbps CPRI interfaces
Frequency
AP700/DD/810/2600MHz 850/900/1800/1900/2100MHz
Frequency band band
/AWS
Volume/Weig
380mm*320mm*140mm/ 480mm*320mm*150mm/23Kg
Volume/Weigh h
20Kg

 Supporting GU, UL or GL dual-mode  Large capacity and easy expansion


 2T4R, supporting 2 sectors or 2*2 MIMO  MCPA based , high PA efficiency

© ZTE All rights reserved 34


Remote Radio Unit — ZXSDR R8862
Specification
G/U/L: 8 TRXs/8 Carriers/2*20M Cells
GU: 8TRXs+4Cs@900MHz
GL : 8TRXs+1*20M Cell@1800M/8TRXs+1*10M
Capacity
Cell@900MHz
422 mm

UL: 4Cs+1*20M/ 2Cs+2*20M@2100MHz


GUL: 4TRXs + 2 Cs + 1*10M Cell@900MHz
Max TOC 2*60W@900/1800/2100MHz; 2*40W@DD

12L/14Kg
TxRx 2T2R
Typical Power GL: 245W (G S4 + L S1, 1800MHz)
Consumption U: 205W (S4, 2100MHz)
G: -113.5dBm@single antenna
 Small size, easy installation Receiver Sensitivity U: -129.2dBm@dual antennas
 Supporting 2T2R, MIMO L: -109.2dBm@dual antennas
capable Power Supply -48V DC, 220V/110V AC
 Supporting GUL multi-mode Interface 2*6Gbps CPRI interfaces
3 RRUs for G S666 + L Frequency band DD/900/1800/2100MHz
S111 or U S444 + L
S111 or Protection Class IP65
G S444 + U S222+ L
S111 Temperature Range -40℃ to +55℃

Volume (H*W*D) 422 mm*218 mm*133 mm


2T2R
Weight 14 kg

© ZTE All rights reserved 35


Remote Radio Unit — ZXSDR R8862A
Specification
G/U/L: 8 TRXs/8 Carriers/2*20M Cells
Capacity GL: 6 TRXs+1*20M Cell@1800M
UL: 4 Carriers (non-MIMO) + 1*20M Cell
2*60W@AP700/850/900/1800/2100/2600M
422 mm

422 mm
Max TOC Hz/AWS
2*40W@2.6GHz
TxRx 2T4R
GL: 245W (G S4 + L S1, 1800MHz)
Typical Power
L: 220W(1800MHz) 210W(2100MHz)
Consumption
215W(2600MHz)
G:-113.5dBm@single antenna
Receiver
L: -109.2dBm@dual antennas
Sensitivity
-112dBm@four antennas
 Small size, easy installation Enhanced uplink sensitivity

Power Supply -48V DC, 220V/110V AC
 Supporting 2T4R, MIMO capable Covering the full band
Interface 2*6 Gbps CPRI interfaces

B1:2100M 60MHZ Frequency band AP700/850/900/1800/2100/2600 MHz/AWS


HZ
B3:1800 75MHZ
MHZ Protection Class IP65
B5:850MHZ 25MHZ
Temperature
-40℃ to +55℃
B7:2600 70MHZ IM3 interference is diminished Range
MHZ through ZTE innovative solution
B8:900M 35MHZ Except AP700: 422 mm*218 mm*133
with port 1 and 4 configured in
HZ mm(12L)/15 kg
TX mode only and port 2 and 3 Volume/Weight
B28:AP70 45MHZ AP700: 422 mm*218 mm*168 mm(15L)/17
in RX mode only.
0 kg
Supporting Full Bandwidth No PIM interference
© ZTE All rights reserved 36
Remote Radio Unit — ZXSDR R8872A
Specification
G/L: 12 TRXs / 2*20M Cells
Capacity
GL: 8TRXs + 1 Cell / 4TRXs + 2Cells

Max TOC 2*80W


415 mm

TxRx 2T4R

Typical Power GL: 340W (G S8 + L S1, 15W/TRX,


Consumption 2*20W/Cell, 1800MHz)
20L/23Kg
G:-113.5dBm@single antenna
Receiver
L: -109.2dBm@dual antennas
Sensitivity
-112dBm@four antennas

Power Supply -48V DC

 High output power, full working bandwidth Interface 2*6/10 Gbps CPRI interfaces
 Supporting 2T4R, MIMO or 2 sectors capable
Frequency
Uplink sensitivity enhanced by 3dB 850/900/1800/1900MHz
 band

Protection
IP65
R8872A Class
75M 75M
Working Band
1710 1785 1805 1880 Temperature
-40℃ to +55℃
Range
MHz
One Operator
1800M Band Volume
415 mm*352 mm*137 mm
(H*W*D)
68M 68M

© ZTE All rights reserved


Weight 23 kg
Rapidly Networking Based on Distributed UniRAN BS

MicroTCA BBU fitted with 19”rack


Small and light, easy for installation, saving project
cost and decreasing construction time
Flexible networking

 50% high-efficient PA to reduce


Compact design, light and small power consumption
 Natural cooling design, 0 dB noise
 Flexible power supply: AC/DC or
remote power
 IP65 protection class to withstand
harsh environment

Rain forest Snowfield Rainstorm Desert

Less space required, flexible installation High reliability, suitable for harsh environment

© ZTE All rights reserved 38


Integrated Outdoor Macro BS — ZXSDR
BS8900B Specification
1 Power system: Power supply + PDM 2 G/U/L: 108TRXs/60CSs/18*20M Cells
L: 10800 RRC_connected users
Baseband unit: B8200 Reserved space Fan
3 4 5 6 Capacity UL 1.35Gbps/DL 2.7Gbps
array RSU: RSU40/RSU60E/RSU82 Battery U: UL 5120 CEs, 690Mbps/DL 5120CEs,
1Gbps
700 mm
700 mm Output RSU60E/RSU40: 140W/80W
750 750
mm mm 700 700 Power RSU82 : 2*80W/2*60W
mm mm
1 1 Typical Power 2405W(S444_G900+S444_G1800+S222_U210
2 1 1 Consumption 0+S111_L1800)
2

2 2 2 G: -113.5dBm@single antenna
3 2 Receiver
2 2 U: -129.2dBm@dual antennas
6 Sensitivity
1750 3 1600 L: -109.2dBm@dual antennas
mm mm
4 3 Power Supply -48V DC, 220V AC, 110V AC

6 Protection
5 5 IP55
class
6
8 E1/T1+1 GE optical or 1 GE/FE
200 200 Abis/Iub/S1/
electrical/CC16B
mm mm X2 interface
Or 2*10GE Optical + 2*GE Electrical/CCE1
RC8910B BC8912B/BC8911B
BBU to RU
2*6 CPRI interfaces per FS/BPN0/BPN2
interface
 All-in-one Solution in One Rack  Large capacity
 Supports GUL multi mode  Various interfaces 1750mm*750mm*700mm /305Kg (RC8910B)
Volume &
 2–8 hours battery backup  Smooth evolution 1600mm*700mm*700mm/150Kg
Weight
(BC8912B/BC8911B)

© ZTE All rights reserved 39


Integrated Outdoor Macro BS — ZXSDR
BS8900B
RC8910B BC8912B/BC8911B PC8910B PC8910A

Appearance
&
Architecture

 200A power supply  200A power supply 4*150Ah battery 2*150Ah


Hardware  2BBU  2BBU battery
Components  9RSU  150Ah
 90Ah battery or 7U space
 150Ah battery or 7U space
 4U reserved
 4U reserved

Single rack:
G: 108 TRXs With external RRUs:
U: 60 CSs G: 360 TRXs
Capacity L: 18 MIMO Cells U: 60 CSs N/A N/A
 GUL: G 48 TRXs+U 24 L: 36 MIMO Cells
CSs+L 6 Cells  GUL: G 144 TRXs+U 24 CSs+L 12 Cells

Data UL: 1.35 Gbps UL: 2.7 Gbps


DL: 2.7 Gbps DL: 7.2 Gbps N/A N/A
Throughput

With silencing cover


Dimension* With silencing cover and With base: With base:
and base:
(mm) base: 1800*700*780 1800*700*700 1000*600*600
1950*750*780

© ZTE All rights reserved 40


BS8900B Application Scenarios
1

Air conditioner
Transmission
device
One container
Power supply
Battery
Indoor BS

One rack

2 MULTI-MODE MULTI-BAND SYSTEM ACHIEVED WITHIN ONE RACK


9 RSUs 3 RRUs

RC8910B 3 RRUs
G G One rack = 5
TDD L
TDD L
TDD L
FDD L
FDD L
FDD L

bands + 4 modes +
G G U U
2 BBUs
U U
150Ah battery
9 RSUs

850M/90 1800M 2100 700M/800M 2.6G


0M 3 M 3 Sectors MIMO 3 Sectors
3 Sectors Sectors 3 MIMO
Sector
s 41
© ZTE All rights reserved
Outdoor Micro BS — ZXSDR BS8922

 L and U mode sharing the


same hardware
 2T2R, supporting 2*2
MIMO
 Small volume, large
capacity
Small & Light Easy Installation

Mode UMTS only Commonly Shared


Single module: 4 CSs in 2*2 TOC Power 2*5 W(2T2R)
MIMO
With external RRUs: 6 CSs in Power 135W (Peak)
Capacity consumption
2*2 MIMO
UL 256CEs/DL 256CEs Power Supply -48V DC,
220V/110V AC
DL 259.2Mbps/UL 69Mbps
Antenna Embedded (9.5dBi)
Frequency 1900/2100 MHz or external antenna
Rx Volume 290 mm*270
Sensitivity -126dBm@dual antennas mm*90 mm

1 CPRI optical interface, 1 GE Weight 8kg


Interface (Electrical/Optical)
© ZTE All rights reserved 42
BS8922 Main Application Scenarios
Hotspots, blind areas or indoor coverage With external antenna or not

U L U L

 In CBD or shopping mall  Integrated antenna


 Blind areas in macro network (9.5dBi), easy installation
 Indoor coverage with zero noise  External antenna
 On the wall or pole enhances the coverage

Cascaded with R8862s

U L

 Supporting RRU cascade


 LTE: 3-level cascade
 UMTS: 4-level cascade
 Extending coverage

B S 8 9 2 2 s u p po r t s e x t e r n a l an t e n n a an d R R U / B S c as c ad e a n d s u p po r t s
DC/MC (UMTS), making a high-quality coverage solution together with macro BSs.
© ZTE All rights reserved 43
Indoor Pico BS — ZXSDR BS8112(Iub)

Item BS8112 (Iub)


Mode UMTS

Working Freq. 2100MHz

TOC Power 2*500mW


ZXSDR BS8112 (Iub) Power
50W
Consumption
 Small and Compact, Plug and Play Bandwidth (MHz) 10
 Flexible Indoor Coverage Solutions
 SOHO/ Government/ Stations/ Capacity 2 CSs, 64 CEs
Hotel/
Airports/ Shopping mall Max. Throughout 43.2Mbps DL/5.76Mbps UL
 Flexible Backhaul Solutions Receiver
-115 dBm
 Low Power Consumption, Energy sensitivity(2R)
Conservation Heat Dissipation
 Compact System, Easy Installation
 All IP Transport Wifi 2*250mW (optional)
 Lower OPEX
Dimension(mm) 245*173*78

Weight 3Kg
© ZTE All rights reserved 44
QCell — ZXSDR R8119+PB1120A
Fiber CAT5e (Ethernet Cable) Index R8119 M182126 R8119 F1821A
L1.8G+G1.8G+U2.1G+L L1.8G +
• Baseband Unit Frequency
BBU 2.6G U2.1G+L2.1G
• Multi-mode
• 6 CPRI / FS Capacity
G 4TRXs+L 1*Cell+U L 2*Cells+U 3Cs +L
board (LTE Cell BW:
3Cs +L 1*Cell 1*Cell
10/15/20M Hz)
• Introducing
MAU 3*(2*100mW)+1*100m 2*200mW+2*2*100
signals from Tx Power
other vendors W mW
Typical Power
• Supports POE 46W 42W
consumption
• 8 x pRRU
pBrid Interface RJ45 RJ45
ge • 4-level
cascading L: -100.8dBm@ dual
G: -107dBm@single
Receiver antennas
• Quite cute antenna
sensitivity U: -119dBm@ dual
• Quad band U/L: Same as the left
• Quick
antennas
pRRU deployment Power supply PoE PoE
• Quality
R8108 R8119/R812
assurance Volume 1.8 L 1.8L
9
Weight 1.4 kg 1.4 kg
• 12*SFP (10G)
MA1020 • Or 24*SMA (RF interface)
pBridge 43.6 *482.6*200 mm/5kg • 8*RJ45(1G)
• 6 GSM TRXs in continuous 20
MHz •4*SFP (10G)
• Or 6 CDMA cells in continuous 10 PB1120A
• AC power supply
BBU-sized
MHz (Standalone) 66*410*306 mm/7kg

© ZTE All rights reserved 45


Contents

 ZTE SDR UniRAN Base Station Overview


 ZXSDR B8200 Product Description
 GUL RRUs Product Description
 ZXSDR BS8900A Product Description

46
ZXSDR BS8900A Basic Cabinets
Baseband Battery
cabinet cabinet

BC8910A PC8910A

800
mm

600
mm
600
mm

Item BC8910A PC8910A


Dimension(H*W*D)
800*600*600 800*600*600
( mm*mm*mm)
Iron:
99 (AC)/76(DC)
Weight of full
64(Auxiliary) Iron:47
configuration
Aluminum: Aluminum: 32
without battery (Kg)
79(AC)/56(DC)
44(Auxiliary)

© ZTE All rights reserved 47


BC8910A Cabinet

 The BC8910A cabinet accommodates the power supply and


baseband components of the ZXSDR BS8900A.
 The baseband unit, AC-DC power supply system, power distribution module,
and heat exchange system can be configured in this cabinet.
 The heat exchange system consists of a fan control system, air duct, and heat
exchanger on the cabinet door.
 Cable troughs, a lightning protection subrack, and a heater or heating film
can be optionally configured.

© ZTE All rights reserved 48


BC8910A Cabinet

 If necessary, a secondary BC8910A cabinet can be equipped to accommodate


transmission equipment. In the secondary BC8910A cabinet, a fan unit and cable
trough are configured and a space of 13 U is provided. The secondary cabinet is
equipped with the DCPD6A DC power distribution unit to supply power for the
cabinet.
© ZTE All rights reserved 49
BC8910A Cabinet

Location Hardware Unit Description

1 Fan subrack BFAN Fan unit in the BC8910A cabinet

Cables in the BC8910A cabinet must be bundled


2 Upper cabling trough
and routed along the cabling trough.

The B201 power subrack converts external input


3 B201 power supply AC power to DC power that can be used in the
ZXSDR BS8900A.

4 BBU subrack Baseband unit in the BC8910A cabinet.

Cables in the BC8910A cabinet must be bundled


5 Lower cabling trough
and routed along the cabling trough.

© ZTE All rights reserved 50


BC8910A Cabinet

Location Hardware Unit Description

Lightning protection subrack optionally


Lightning protection configured in the BC8910A cabinet. For details,
6
subrack refer to the LPU Lightning Protection Subrack
manual.

Reserved for other devices, for example,


7 Reserved space (4 U)
microwave IDU equipment.

Heater, 3 U or 4 U in height, powered by an AC


supply, optionally configured in the BC8910A
cabinet, and located on the bottom of the
8 Heater
BC8910A cabinet. It is configured only when the
minimum ambient temperature is lower than –
15°C.

9 Door Used for keeping the cabinet from water ingress.

© ZTE All rights reserved 51


B201 Power Subrack

 The B201 power subrack converts external input AC power to DC


power that can be used in the ZXSDR BS8900A.

© ZTE All rights reserved 52


External View of the B201 Power Subrack

No. Name Description

Both AC distribution and DC distribution units are enclosed


in an integrated case. The AC distribution unit connects,
Power
1 protects, and distributes AC power supply. The DC
distribution unit
distribution unit outputs DC power, connects storage
batteries, and protects load.

It is located at the far right-hand side of the integrated case


and used to implement the displaying, control, alarm, and
monitoring functions. The system can operate properly
2 Monitoring unit without the monitoring unit. In this case, however, the
remote functions (teleindication, remote control, and remote
measurement) are disabled and the battery set keeps being
floatingly charged.

The B201 power subrack can be equipped with four rectifiers


3 Rectifier set
in full configuration

© ZTE All rights reserved 53


PC8910A Cabinet (Natural Heat Dissipation)

 The PC8910A cabinet is the outdoor storage battery cabinet of


the ZXSDR BS8900A.
 If the external AC power supply is switched off, the backup
batteries supply power to the ZXSDR BS8900A to ensure
continuous operation of the ZXSDR BS8900A.
 The nominal capacity of built-in storage batteries is 300 AH. Up
to two sets of storage batteries can be equipped in the PC8910A
cabinet.
 The capacity of each set is 135 AH (GEL batteries) or 150 AH
(AGM batteries).

© ZTE All rights reserved 54


Power Distribution Unit

 External View of the Front Panel of the Power Distribution Unit

© ZTE All rights reserved 55


Power Distribution Unit
No. Name Description
Battery input terminals. Up to 4 sets of batteries can be equipped for
1 BATT Input
two cabinets, for example, two PC8910A cabinets.
Input terminal of an external AC power and output terminal of an AC
2 AC Input/AC Out
power.
AC INPUT/AC Control switches for external AC power input branches.
3
OUT Control switches for AC power output branches.
Lightning protection for the system. The window is displayed in green
when the arrester operates properly. The window is displayed in red if
4 AC SPD the arrester is damaged by lightning strike.
The arrester can be plugged, unplugged, or replaced without power
shutdown.
Control switches of the DC power for four loads. They control closing
5 BLVD/LLVD1 and opening of DC output branches and provide overload protection
for the DC output branches.
Input control switches for charging of four sets of batteries. They
6 BATT control closing and opening of two sets of battery branches and
provide overload protection for the battery branches.
7 DC OUT DC power output terminals and battery input terminals.

© ZTE All rights reserved 56


Monitoring Unit of the B201 Power Subrack

 1.USB interface 2.RJ45 Ethernet interface 3.Buttons 4.LCD 5.Indicators

© ZTE All rights reserved 57


External View of a Rectifier

1.Indicators 2.Query button 3.Fan unit

© ZTE All rights reserved 58


PC8910A Cabinet (Natural Heat Dissipation)

1.Batteries 2.Battery heating plate


© ZTE All rights reserved 59
Thank you

Potrebbero piacerti anche