Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Datos
Distancia interfaz A-B: 37mm=0.037m
Distancia interfaz B-C: 68mm=0.068m
Área de un circulo: π*r2 =4.908x10-4 m2
Potencia de 10 W
Sección A
T= -92.11x+44.448
Sección B
T= -90.4x+40.156
Sección C
T= -121.17x+42.142
A=4.9088𝑥10−4 𝑚2
𝑄
ℎ𝑐 =
𝐴 ∗ ∆𝑡𝑖𝑛𝑡𝑒𝑟𝑓𝑎𝑠𝑒
10.274𝑊 𝑊
ℎ𝑐 = 2
= 4950 2 𝐴𝑝𝑟𝑜𝑥𝑖𝑚𝑎𝑑𝑎𝑚𝑒𝑛𝑡𝑒
(0.00049088𝑚 ) ∗ (4.228°𝐶) 𝑚 °𝐶
∆𝑡𝑖𝑛𝑡𝑒𝑟𝑓𝑎𝑠𝑒 4.228°𝐶
𝑅𝑐 = 𝑄 =
10.274𝑊/0.00049088m2
𝐴
Rc=𝟐. 𝟎𝟐𝐗𝟏𝟎−𝟒 𝐦𝟐 °𝐂/𝐖 aprox
Sección B-C
𝑄
ℎ𝑐 =
𝐴 ∗ ∆𝑡𝑖𝑛𝑡𝑒𝑟𝑓𝑎𝑠𝑒
10.274𝑊 𝑊
ℎ𝑐 = 2
= 190271 2 𝐴𝑝𝑟𝑜𝑥𝑖𝑚𝑎𝑑𝑎𝑚𝑒𝑛𝑡𝑒
(0.00049088m ) ∗ (0.11°𝐶) 𝑚 °𝐶
∆𝑡𝑖𝑛𝑡𝑒𝑟𝑓𝑎𝑠𝑒 0.11°𝐶
𝑅𝑐 = 𝑄 =
10.274𝑊/0.00049088m2
𝐴
Rc=𝟓. 𝟎𝑿𝟏𝟎−𝟔 𝒎𝟐 °𝑪/𝑾 Aprox
Potencia de 20 W
Sección A
T= -201.79x+57.47
sección B
T= -163.95x+55.352
sección C
T= -162x+50.318
Sección A-B
ΔT interface = 50.00-49.29=0.718°C
Qcond= hc *A *ΔTinterface
𝑄
hc= A ∗ΔTinterface
20.27𝑊 𝑊
ℎ𝑐 = 2
= 57511.4 2 𝐴𝑝𝑟𝑜𝑥𝑖𝑚𝑎𝑑𝑎𝑚𝑒𝑛𝑡𝑒
(0.00049088m ) ∗ (0.718°𝐶) 𝑚 °𝐶
∆𝑡𝑖𝑛𝑡𝑒𝑟𝑓𝑎𝑠𝑒 0.718°𝐶
𝑅𝑐 = 𝑄 =
20.27𝑊/0.00049088m2
𝐴
Rc=𝟏. 𝟕𝑿𝟏𝟎−𝟓 𝒎𝟐 °𝑪/𝑾 Aprox
Sección B-C
∆𝑡𝑖𝑛𝑡𝑒𝑟𝑓𝑎𝑠𝑒 4.90°𝐶
𝑅𝑐 = 𝑄 =
20.27 𝑊/0.00049088m2
𝐴
Rc=𝟏𝟏. 𝟗𝑿𝟏𝟎−𝟓 𝒎𝟐 °𝑪/𝑾 Aprox
Potencia de 30 W
Sección A
T= -288.97x+69.308
Sección B
T= -120.75x+60.096
Sección C
T= -186.68x+56.012
Sección A-B
32.4𝑊 𝑊
ℎ𝑐 = = 22079.5 𝐴𝑝𝑟𝑜𝑥𝑖𝑚𝑎𝑑𝑎𝑚𝑒𝑛𝑡𝑒
(0.00049088m2 ) ∗ (2.98938°𝐶) 𝑚2 °𝐶
∆𝑡𝑖𝑛𝑡𝑒𝑟𝑓𝑎𝑠𝑒 2.98938°𝐶
𝑅𝑐 = 𝑄 =
32.4𝑊/0.00049088m2
𝐴
Rc=𝟒. 𝟓𝑿𝟏𝟎 𝒎 °𝑪/𝑾 Aprox
−𝟓 𝟐
Sección B-C
32.4𝑊 𝑊
ℎ𝑐 = = 7704.44 𝑎𝑝𝑟𝑜𝑥𝑖𝑚𝑎𝑑𝑎𝑚𝑒𝑛𝑡𝑒
(0.00049088m2 ) ∗ (8.567°𝐶) 𝑚2 °𝐶
∆𝑡𝑖𝑛𝑡𝑒𝑟𝑓𝑎𝑠𝑒 8.567°𝐶
𝑅𝑐 = 𝑄 =
32.4𝑊/0.00049088m2
𝐴
Potencia de 10W:
Y= -98.526x + 52.54
Y= -98.526(0.037) + 52.54
Ta1= Y = 48.8945 oC
Y= -388.86x + 62.305
Y= -388.86(0.037) + 62.305
Tb1= Y = 47.9172 oC
Y= -388.86(0.068) + 62.305
Ta2 = Y = 35.86 oC
Y= -111.9x + 41.37
Y= -111.9(0.068) + 41.37
Tb2 = Y = 33.76 oC
Sección A-B
∆𝑇𝑖𝑛𝑡𝑒𝑟𝑓𝑎𝑐𝑒
𝑅𝑐 = ℎ𝑐 =
𝑄̇𝑐𝑜𝑛𝑑,𝑛 /𝐴
Q=10.274 W
A= 0.000490875𝑚2
0.9773 𝑚2 °∁ 1
𝑅𝑐 = 10.274/(4.9×10−4 )= 0.47× 10−4 =ℎ
𝑊
𝑊
ℎ = 21410.7
𝑚2 °∁
Sección B-C
2.1 𝑚2 °∁ 1
𝑅𝑐 = 10.274/(4.9×10−4 )=1× 10−4 =ℎ
𝑊
𝑊
ℎ = 9964.12 2
𝑚 °∁
Potencia 20W
Sección A
y = -189.39x + 74.437
Sección B
y = -755.58x + 94.793
Sección C
y = -145.37x + 47.783
Ta1= Y = 67.42oC
Tb1= Y = 66.83oC
Ta2= Y = 43.41oC
Tb2= Y = 37.89oC
Sección A-B
Q=20.27 W
A= 0.000490875𝑚2
0.593 𝑚2 °∁ 1
𝑅𝑐 = 20.27/(4.9×10−4 )= 0.14× 10−4 =ℎ
𝑊
𝑊
ℎ = 69613.8 2
𝑚 °∁
Sección B-C
5.52 𝑚2 °∁ 1
𝑅𝑐 = 20.27/(4.9×10−4 )= 1.34× 10−4 =ℎ
𝑊
𝑊
ℎ = 7478.82
𝑚2 °∁
Potencia 30W
Sección A
y = -164.19x + 82.785
Sección B
y = -878.05x + 105.67
Sección C
y = -164.24x + 50.583
Ta1= Y = 76.70oC
Tb1= Y = 73.18oC
Ta2= Y = 45.96oC
Tb2= Y = 39.42oC
Sección A-B
Q=30.24W
A= 0.000490875𝑚2
3.527 𝑚2 °∁ 1
𝑅𝑐 = 32.4/(4.9×10−4 )= 0.53× 10−4 =ℎ
𝑊
𝑊
ℎ = 18705 2
𝑚 °∁
Sección B-C
6.54792 𝑚2 °∁ 1
𝑅𝑐 = 32.4/(4.9×10−4 )= 0.99× 10−4 =ℎ
𝑊
𝑊
ℎ = 10077.7
𝑚2 °∁
20 67.4295 66.84 43.41 37.89 0.14 × 10−4 1.34 × 10−4 69613.8 7478.82
30 76.71 73.18 45.96 39.41 0.53 × 10−4 0.99 × 10−4 18705 10077.7
Conclusiones
La resistencia térmica total resulta de la suma aritmética de cada una de las resistencias térmicas
que se encuentran en la trayectoria de la transferencia de calor.
La razón de transferencia de calor estacionaria, a través de un medio de capas múltiples es
constante, y por consiguiente, debe ser la misma a través de cada una de las capas.
La resistencia térmica por contacto es la inversa de la conductancia térmica por contacto.
Los valores van a variar mucho por ende puede haber un porcentaje de error en cada valor
obtenido, todo este dado en aproximaciones