Sei sulla pagina 1di 3

DOC. NO.

: -
DATASHEET REV. NO. : B
PAGE : COVER

OSBL PROCESS DATASHEET FOR CONDENSATE PIG


RECEIVER (PR-5102)

PROJECT NAME : CA MAU GAS PROCESSING PLANT PROJECT


CLIENT : PETROVIETNAM GAS JOINT STOCK CORP
CONTRACTOR : PEN-PTSC CONSORTIUM

B 21-MAR-2018 Issue for Approval J.S.SEO H.S.YOO S.H.LEE

A 28-JUL-2017 Issue for Approval J.S.SEO H.S.YOO S.H.LEE

PEN PVGAS
REV. NO. DATE DESCRIPTION PREP'N REVIEW
APPROVAL APPROVAL

PEN PVGAS
REV. NO. DISCIPLINE PREPARATION REVIEW
APPROVAL APPROVAL

A PROCESS

J.S.SEO H.S.YOO S.H.LEE

This DOCUMENT is the property of PetroVietnam Gas Joint Stock Corporation. Therefore, it shall not be released to any third
party without permission of authorized personnel of the PetroVietnam Gas Joint Stock Corporation.
CONDENSATE PIG RECIEVER PROCESS DATA SHEET PAGE : 2 of 3

REV A B
PROJECT NAME : CA MAU GAS PROCESSING PLANT PROJECT PREP J.S.SEO J.S.SEO
CLIENT : PETROVIETNAM GAS JOINT STOCK CORP CHKD H.S.YOO H.S.YOO
JOB NO. : 140080 APPD S.H.LEE S.H.LEE
REV DOC. NO. :- DATE 28-JUL-2017 21-MAR-2018

Item No. PR-5102 Service CONDENSATE PIG RECEIVER 1

No. Req'd 1 (ONE) Type HORIZONTAL TYPE (PORTABLE) 2

Regulation Code ASME B31.8 3

1. GENERAL 5

Type : Horizontal Type (Portable) 7

Quantity : One (1) 8

Temperature 9

Design : 70 ℃ 10

Operating : 18 ~ 44 ℃ 11

Pressure 12

Design : 12.4 barg 13

Operating : 7.7 ~ 8.0 barg 14

Fluid : Condensate 15

Specific gravity : 0.649 ~ 0.624 16

Viscosity : 0.284 ~ 0.223 cP 17

18

19

2. MECHANICAL DESIGN DATA 20

21

Item Major Barrel Minor Barrel 22

Barrel Diameter 8 inch 6 inch 23

Wall Thickness VTC VTC 24

Head Type End Closure Flange 25

Corrosion Allowance CS + 3 mm CS + 3 mm 26

Connection Nozzle Refer to the section 5. SKETCH 27

28

29

3. PIG INFORMATION 30

31

Pig signaller 32

Quantity : One (1) 33

Type : Set-in mechanical type 34

35

36

4. OTHER INFROMATION 37

38

Skid : VTC 39

Saddle : VTC 40

Platform, Ladder & Step : VTC 41

Lifting Lugs : VTC 42

Earthing Lugs : VTC 43

Cradle : VTC 44

Davit : VTC 45

Manual Chain Block : VTC 46

Key Interlock System : VTC 47

Instruments : VTC 48

49

50

51

52

53

54

55

56

57
CONDENSATE PIG RECIEVER PROCESS DATA SHEET PAGE : 3 of 3

REV A B
PROJECT NAME : CA MAU GAS PROCESSING PLANT PROJECT PREP J.S.SEO J.S.SEO
CLIENT : PETROVIETNAM GAS JOINT STOCK CORP CHKD H.S.YOO H.S.YOO
JOB NO. : 140080 APPD S.H.LEE S.H.LEE
REV DOC. NO. :- DATE 28-JUL-2017 21-MAR-2018

Item No. PR-5102 Service CONDENSATE PIG RECEIVER 1

No. Req'd 1 (ONE) Type HORIZONTAL TYPE (PORTABLE) 2

Regulation Code ASME B31.8 3

5. SKETCH 5

Pig Receiver 7

8
TOTAL LENGTH (L)
9
(Note 1)
10
MINOR BARREL (A) MAJOR BARREL (B)
Minimum Minimum 11
(VTC) (VTC)
12
N3 N4
13

14
N2
15
END CLOSURE
DIAMETER (C) 16
250 mm
N1 (Note 1) 17

18

19
N5
20

CONNECTION NO. DESCRIPTION REQUIRED NO. SIZE RATING 21

N1 INLET / OUTLET 1 6" 150# RF 22

N2 PIG SIGNALLER (Note 1) 1 VTC 150# RF 23

N3 TRV (Note 1) 1 1" 150# RF 24

N4 PRESSURE INDICATOR (Note 1, 2) 1 VTA 150# RF 25

N5 DRAIN (w/ Valve, Note 4) 1 3/4" 150# RF 26

27

28

29

30

31

32

33

34

6. NOTES 35

36

VTA : Vendor To Advise 37

VTC : Vendor To Confirm 38

1. It should be supplied by vendor. 39

2. Pressure indicator to be visible for an operator standing at the pig receiver end closure. 40

3. Pig signallers shall be provided for pig receiver by vendor. 41

3. Length of pig receiver shall be accommodated for all the specified pig type. 42

4. Drain point should be minimized from pig receiver end closure. 43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

Potrebbero piacerti anche