Sei sulla pagina 1di 6

5/18/2018 Design Example of Steel Beams According to Eurocode 3 - Structville...

Home About Contact     

A HUB FOR CIVIL ENGINEERING RELATED


DESIGNS, ANALYSIS, DISCUSSION,
INFORMATION, AND KNOWLEDGE.....

 HOME STRUCTVILLE RESEARCH ABOUT US CONTACT US OUR PRODUCTS AND SERVICES

 TRENDING POSTS: EUROCODE 7 Geotechnical Design of Cantilever Retaining Walls to Eurocode 7: Solved Example EUROCODE 2 How To Apply

  Beams  Eurocode 3  Steel Structures  Design Example of Steel Beams According to Eurocode 3 RM1 = Unlimited YouTube
YouTube all you want with our tiniest coupon ever.
Only with Internet Cili Padi. new.digi.com.my

Design Example of Steel Beams According to Eurocode FACEBOOK

3 Structville Engineering
5,896 likes

by Ubani Obinna Ranks on January 22, 2018 in Beams, Eurocode 3, Steel Structures

Like Page

Be the first of your friends to like this

STRUCTVILLE RESEARCH

Introduction
This post deals with the design of simply supported I-beam section subjected to permanent and variable loads according
to Eurocode 3. The design involves selecting the appropriate section that will satisfy limit state requirements.
Welcome to the unique page of Structville
can easily download research papers, arti
drawings, textbooks, and even upload you
Problem Statement
It is desired to select an appropriate section to satisfy ultimate and serviceability limit state requirements for a laterally
STRUCTVILLE DESIGN MANUAL
restrained simply supported beam that is subjected to the following loads;
Permanent Load Gk = 38 kN/m
Variable Load Qk = 12 kN/m

The length of the beam = 7.5m

Solution

https://www.structville.com/2018/01/design-example-of-steel-beams-according.html 1/6
5/18/2018 Design Example of Steel Beams According to Eurocode 3 - Structville...
At ultimate limit state,
PEd = 1.35Gk + 1.5Qk

PEd = 1.35(38) + 1.5(12) = 69.3 kN/m

You can purchase or download the previe


highly interactive design manual by clickin

GOOGLE+ BADGE

Ubani Obinna Ranks


Ubani Obinna Ranks

Follow

224 followers

ABOUT ME
An advanced UK beam S275 is to be used for this design.
Ubani Obinna Ranks
Fy = 275 N/mm2 Follow 224

γm0 = 1.0 (Clause 6.1(1) NA 2.15 BS EN 1993-1- 1:2005) Purpose driven personality
Bachelors Degree (B.Eng) i
Engineering from Nnamdi Azikiwe Univers
Passionate about civil engineering profes
experienced in structural analysis and des
View my complete profile

The required section is supposed to have a plastic modulus about the y-y axis that is greater than;
Wpl,y = My,Edγm0/Fy

 Wpl,y = (487.265 × 103 × 1.0)/275 = 1771.872 cm3

From steel tables, try section 457 x 191 x 82        Wpl,y = 1830 cm3

CHECK OUT ALSO....


Design of Steel Beams to BS 5950 - 1: 2000
FOLLOW BY EMAIL
Structural Analysis of Compound Arch-Frame Structure

https://www.structville.com/2018/01/design-example-of-steel-beams-according.html 2/6
5/18/2018 Design Example of Steel Beams According to Eurocode 3 - Structville...

Enter your email address to subscribe to this blog


notifications of new posts by email.
Properties
Email address...
 h = 460.0mm; b = 191.3mm; d = 407.6mm; tw = 9.9mm; tf; r = 10.2mm; A = 104 cm4; Iy = 37100 cm4; Iz = 1870 cm4; Wel,y =
SUBMIT
1610 cm3; Wel,y = 1830 cm3

hw = h - 2tf = 428.0mm POPULAR POSTS

Structural Design of Steel F


 E (Modulus of elasticity) = 210000 N/mm2  (Clause 3.2.6(1)) Connection

Classi cation of section


Analysis and Design of Cur
 ε = √(235/Fy) = √(235/275) = 0.92 (Table 5.2 BS EN 1993-1- 1:2005)
Circular Beams in a Reserv

Outstand flange: flange under uniform compression c = (b - tw - 2r)/2 = [191.3 - 9.9 - 2(10.2)]/2 = 80.5mm
Analysis of Column Loads i
By Considering Beam Supp
c/tf = 80.5/16.0 = 5.03 Reactions

Preparation of Bar Bending


The limiting value for class 1 is c/tf  ≤ 9ε = 9 × 0.92
For Floor Slabs
5.03 < 8.28
Therefore, outstand flange in compression is class 1
PRACTICAL ANALYSIS AN
OF STEEL ROOF TRUSSES
Internal Compression Part (Web under pure bending) EUROCODE 3: A SAMPLE
c = d = 407.6mm
c/tw = 407.9/9.9 = 41.17 What is wrong with this se
structural detailing?

The limiting value for class 1 is c/tw ≤ 72ε = 72 × 0.92 = 66.24


Design of Pile Foundation
41.17 < 66.24
Load Test (Eurocode 7)
Therefore, the web is plastic. Therefore, the entire section is class 1 plastic.

How to Prepare the Gener


Arrangement (GA) of a Bui

Industrial industrial diesel generators and


electric power generator sets
Gensets from 100-2000+ kW RECENT POPULAR COM

Structville Design Competit


Member Resistance Veri cation Students (Prizes to be won)
 Ubani Obinna Ranks  May
Moment Resistance
For the structure under consideration, the maximum bending moment occurs where the shear force is zeo. Therefore, the Geotechnical Design of Can
bending moment does not need to be reduced for the presence of shear force (clause 6.2.8(2)) Retaining Walls to Eurocod
Example
 Ubani Obinna Ranks  May
MEd/Mc,Rd ≤  1.0 (clause 6.2.5(1))

How To Apply Wind Load on


Mc,Rd = Mpl,Rd = (Mpl,y × Fy)/γm0 Buildings
 Ubani Obinna Ranks  May

Mc,Rd = Mpl,Rd = [(1830 × 275)/1.0] × 10-3 = 503 kNm Simple Proofs Why Shorter
More Critical in Slab Design
 Ubani Obinna Ranks  May
MEd/Mc,Rd = 487.265/503 = 0.9687 < 1.0 Ok

An Introduction To Isogeom
Shear Resistance (clause 6.6.2) Analysis (IGA)
 Ubani Obinna Ranks  Apr
The basic design requirement is;

VEd/Vc,Rd ≤  1.0 FOLLOW US

Vc,Rd = Vpl,Rd = Av(Fy / √3)/γm0 (for class 1 sections)  Facebook

For rolled I-section with shear parallel to the web, the shear area is;
 Twitter

Av = A - 2btf + (tw + 2r)tf (for class 1 sections) but not less than ηhwtw
 Google+

 Follow up on Linkedin

https://www.structville.com/2018/01/design-example-of-steel-beams-according.html 3/6
5/18/2018 Design Example of Steel Beams According to Eurocode 3 - Structville...

Av = (104 × 102 - (2 × 191.3 × 16) + [9.9 + 2(10.2)] × 16 = 4763 mm2


 Follow us on Instagram
η = 1.0 (conservative)

ηhwtw = (1.0 × 428 × 9.9) = 4237 mm2


FACEBOOK
4763 > 4237

Therefore, Av = 4763 mm2


Structville Engineering
5,896 likes

The shear resistance is therefore;

Vc,Rd = Vpl,Rd = [4763 × (275 / √3)/1.0]  × 10-3 = 756 kN


Like Page

VEd/Vc,Rd = 259.875/756 = 0.343 < 1.0 Ok Be the first of your friends to like this

Shear Buckling
BLOG ARCHIVE
Shear buckling of the unstiffnened web will not need to be considered if;

January (11)
hw/tw ≤  72ε/η

hw/tw = 428.0/9.9 = 43 TAGS


72ε/η  = (72 ×  0.92)/1.0  = 66
BEAMS (24) BRIDGES (5)

43 < 66 Therefore shear buckling need not be considered. CABLE STRUCTURES (1) COLUMN (10)

CONCRETE (1) CONNECTION DESIGN (1


Serviceability limit state
CONSTRUCTION (12) DYNAMIC ANALYSIS
Vertical deflections are computed based on variable loads. Permanent loads need not be considered.(BS EN 1993-1-1 NA
2.23) ENGINEERING MATHEMATICS (1) EUROCO

EUROCODE 3 (11) EUROCODE 7 (3)


Qk = 12 kN/m
FORCE METHOD (9) FOUNDATIONS (7)

FRAMES (17) GEOTECHNICAL ENGINEERIN


w = 5ql4/384EI

GUIDES (8) INFORMATIVE POSTS (11)

w = (5 × 12 × 75004)/(384 × 210000 × 37100 × 104) = 6.345mm  LITERATURE REVIEW (1)


Span/360 = 7500/360 = 20.833mm (BS EN 1993-1-1 NA 2.23)
MATERIALS ENGINEERING (1) OPINION

 6.345mm < 20.833mm. Therefore, deflection is satisfactory PLASTIC ANALYSIS (1) PROGRAMMING

PROMOTIONS (4) QUANTITY ESTIMATION


Thank you for visiting Structville Today.
REINFORCED CONCRETE DESIGN (33)

STAAD PRO (5)

STATICALLY DETERMINATE STRUCTURES (10)

STATICALLY INDETERMINATE STRUCTURES (1

STEEL STRUCTURES (15)

STRUCTURAL ANALYSIS (48) TALL BUILDI

THIN PLATES (2) TIMBER STRUCTURES

TRUSSES (7) WIND LOAD (1)

Have you read?


Thickness design of column base plate connections

Our amazing facebook interactive page can be found at;


www.facebook.com/structville

Share This:  Facebook  Twitter  Google+  Pinterest  Linkedin

https://www.structville.com/2018/01/design-example-of-steel-beams-according.html 4/6
5/18/2018 Design Example of Steel Beams According to Eurocode 3 - Structville...

RECOMMENDED ARTICLES

Design of Bolted Beam Splice Connections According to EC3


In the erection of steel structures, there is always need to join steel members for the purpose of continuity.
We cannot always have full lengths of m...

Member Design of a 22m Span Steel Roof Truss


IntroductionWe all need a roof over our head. Nowadays, architects frequently use roof pattern and design to
enhance the aesthetics and functionality ...

Structural Design of Steel Fin Plate Connection


1.0 IntroductionThe fin plate connection is very popular in the construction industry due to its ease of
erection, and the absence of shared bolts in ...

Thickness Design of Column Base Plate Using Prokon Software


Last year, I made a submission here on how to carry out the thickness design of column base plates.See post
below;Thickness Design of Column Base Plat...

Analysis of Industrial Gable Frames


1.0 IntroductionIndustrialization is one of the major keys to development and sustainable economy. Industrial
structures are usually very easy to iden...

Analysis of Elevated Steel Tank Using Staad Pro


Overhead steel tank is one of the most adopted water storage system due to lots of reasons. The speed and
ease of construction, flexibility in support...

 NEWER ARTICLE OLDER ARTICLE 


How To Apply Load Model 1 (LM 1) On Highway Bridges Precise Moment Distribution Analysis Of Non-Sway Frames

NO COMMENTS: 

Enter your comment...

Comment as: Select profile.

Publish Preview

industrial diesel generators


Industrial and electric power generator
Gensets sets from 100-2000+ kW

PAGES ABOUT ME CONTACT FORM

Name
Home Ubani Obinna Ranks
Follow 224
Our Products and Services Email *
Purpose driven personality with a
About Us
Bachelors Degree (B.Eng) in Civil
Engineering from Nnamdi Azikiwe University, Awka. Message *
Disclaimer
Passionate about civil engineering profession, and
Our Policies experienced in structural analysis and design.
View my complete profile

Send

https://www.structville.com/2018/01/design-example-of-steel-beams-according.html 5/6
5/18/2018 Design Example of Steel Beams According to Eurocode 3 - Structville...

Copyright © 2018 Structville...      

https://www.structville.com/2018/01/design-example-of-steel-beams-according.html 6/6

Potrebbero piacerti anche