This object of the guide will be to show you how to enable BPC in NetWeaver BW 7.5. We will start the
steps from fresh NetWeaver Install. For most of the part, I will follow the official BPC Installation Guide for
BPC 10.1 on NW 7.4, but hopefully, will make it a bit more understandable.
Here it is the right time to acknowledge that I am not a Basis consultant, and instead a BPC Functional
Consultant with Accounting background. Please do not use this guide for a production application.
You will need to save and activate the changes in the profile. To take effect, you will need to restart the
SAP system, because they are on OS level.
/sap/EPM_BPC
/sap/public/bc
/sap/es/ina/
/sap/bw/cs
/sap/bc/ui5_ui5/sap/bpcwebclient
/sap/bw/ina
/sap/public/myssocntl
For the EPM Connector activate following.
/sap/bw/xml/soap/xmla/
In the configuration screen select the appropriate Protocol, enter Client and Language and select Logon
Layout. If you want to suppress any warnings on the Logon screen, choose “Do Not Display Warnings.”
Turn on Planning Application Kit and BPC Embedded for HANA
With the help of transaction SM30 enter into table maintenance – RSPLS_HDB_ACT.
Maintain the entries as shown in the screenshot.
Confirm following Namespaces and Components are modifiable during this activation:
/CPMB/
/1CPMB/
/B28/
/POA/
Customer Name Range
General SAP Name Range
Software Components:
CPMBPC
HOME
LOCAL
However, for production use, after installation SAP is recommending following components be
unmodifiable.
Namespaces:
/1CPMB/
Customer Name Range
General SAP Name Range
/CPMB/
/B28/
Software Components:
CPMBPC
If you don’t have BWREMOTE user, it will help you to create one. When you have user and password, hit
save. It will create the necessary connection which you will see in transaction SM59.
Make the communication type Unicode. Again Connection and Authorisation check is highly
recommended.
Assign the RFC Connection in SPRO
Enter in Field Name – RFC_DESTINATION and Value field your RFC Connection ID.
Activate EnvironmentShell
Go to transaction SA38/SE38 and type UJS_ACTIVATE_CONTENT. Enter into the report and keep the
selection as shown in the screenshot.
After successful activation of EnvironmenShell, you should be able to use your BPC system. To access
your web admin, use the following URL. Replace server IP Address and HTTP Port (defined beforehand)
with yours.