Sei sulla pagina 1di 8

Product manual

The energy saving ventilator


TEV-3110-60

Table of contents: Page:

Technical description ......................................................... 2


Restrictions........................................................................... 2
Delivery ................................................................................ 2
Advantages............................................................................. 2
Technical data ...................................................................... 3
Mounting instruction and recommendations.............4-5
Safety information .............................................................. 6
Complementary products and accessories .................. 6
Spare part drawing............................................................7-8
Spare part list........................................................................ 8
CE declaration of conformity for machinery. ...................... 8

Thank you for buying a Plymovent product.


Before you unpack and put it into operation please read
this product manual, and follow the instructions.

THIS manual should be handed over


and kept by the service department
after the installation!

Sales office Canada


Plymovent AB USA
Plymovent Corp. Plymovent Inc
Kopparbergsgatan 2 24- 1200 Aerowood Dr
SE-214 44 MALMÖ 115 Melrich Road
Cranbury, New Jersey 08512, USA Mississauga, On L4W 2S7, Canada
SWEDEN Tel: +1 (905) 564-4748
Tel: +46 40 30 31 30 Tel. + 1 609 395 3500
Fax: +1 (905) 564-4609
Fax: +46 40 30 31 40 Fax. + 1 609 655 0919
info@plymovent.ca
info@plymovent.se info@plymovent.com

090424
Technical description

© Copyright 2008:All rights reserved.All information within this printed matter may not be reproduced,
The energy saving ventilator:TEV
handed over, copied, xeroxed or translated into another language in any form or means without written
permission from plymovent Ab. plymovent Ab reserves the right to make design changes.

Ventilator for extracting welding


fumes,dust, oilmist and exhaust gasses.
To achieve the optimum performance and assure maximum safety, please read
this manual carefully before installing and using this product.

Technical description
Plymovent offers a wide range of ventilators, fulfilling every demand for ventilation in
the working environment. The ventilators are equipped with a non-sparking impeller of
aluminum, specially designed to resist welding and other harmful fumes as dust, oil mist
and exhaust gasses. By using the Plymovent control equipment for operating the venti-
lators and other energy saving devices we support in decreasing building costs (like the
ES-90, ICE-LC/MD, M-1000 and OS4) together with Y/D start equipment or a frequency
transformer, the performance of the ventilator is utilized to its optimum. A correct way
of installing and use of the operating systems enable for a more efficient extraction rate
and thereby also reduce operating cost for the end-user. The ventilators are intended and
designed for mounting to a central ducting system.

Restrictions
The Plymovent ventilator is not to be used in explosive environments and this application
is therefore prohibited. Using the ventilator for extracting gasses that are explosive is
also strictly prohibited. The maximum airflow temperature is 80°c / 176°F and ambient
temperatures should not exceed 40°c / 104°F. When using the ventilator in an outdoor
environment a cover is required which protects the fan and electric motor from the
elements. Next to this vibration insulation from the mounting surface to the fan as well as
to the ducting is strongly recommend.

Delivery
The ventilator is delivered with an upward outlet and supplied with a protective screen on
both the inlet and outlet.

Advantages
• non-sparking impeller designed to handle vehicle exhaust gasses, volatile fumes and
dust. ( not specially designed to extract explosive gases!)
• High capacity ventilator and low sound level
• Housing constructed in galvanized steel, with a powder coat finish.
• All ventilators are equipped with a protective screen at both the inlet and outlet.
• Due to use of durable materials the ventilator has a long working life.
• The flexible ventilator housing enable for simple duct connections on both the inlet
and outlet*

* The outlets require round sleeves, please see “complementary equipment”, page 6

Note! Plymovents product responsibility only applies if the


equipment is not altered or added to, other than with the
written consent of Plymovent AB.

TEV-/US,CA/2/8
Model: TEV-3110 - 60 DIMENSIONAL DATA
PlymoVent reserves the right to make
G F L design and technical changes.
E

mm inches mm inches
A 640 25 3/16 I 288 11 11/32

I
B 640 25 3/16 J 373 14 11/16
C 230 9 1/16 K 267 10 1/2

B
D 200 7 7/8 L 83 3 9/32
E 160 6 5/16 M 288 11 11/32

H
F 254 10 N 355 13 31/32
G 472 18 9/16 O 25 1
H 355 13 31/32 P 99 3 15/16
O
J K
P
A
C

TEv 3110 TECHNICAL DATA


10 5 Fan specifications Motor specifications
9 Construction: AMCA Type - B Frame size: NEMA 56C 3-ph
8 4 Drive type: Direct drive Motor type: TEFC (IP 55)
Impeller type: Backward incline Rated output: 3.0 HP
7
Impeller material: Aluminum Thermal protection: No
6 3
Impeller diameter: 12.4 inch CSA: Yes
ps (in w G)

5 Impeller width: 4.33 inch CE-listed: Yes


hp

4 2 Hub size: 5/8 inch Continuous duty 104°F/40°C


3 Discharge style: Rotational 90° 3 phase motor
Shaft seal: Rubber Voltage 208-230/460/575
2 1
Housing material: Galvanized steel Full load current: 8.4-7.6/3.8A
1 Housing finish: Epoxy powder coat Motor RPM 3450
0 0 Total fan weight: 85 lbs Service factor 1.15
0 500 1000 1500 2000 2500 3000
1 phase motor
cfm Voltage 208-230/460 V
Electrical power is available for all inter-
Performance shown is for installation type D: Ducted inlet, Ducted outlet. Full load current: 13.5/6.75 A
Performance ratings do not include the effects of appurtenance in the airstream.
national electrical power sources.
Motor RPM 3500
Performance measured at a speed of 3500 RPM and the effeciency of the motor.
Service factor 1.15

SOUND POWER DATA


Octave Band (Hz)

Speed Pressure 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 4000 Hz LwA Sones
in WG
3500 0 99 103 99 97 91 86 83 78 98 51
3500 1 100 103 99 96 90 85 82 77 97 50
3500 2 100 104 99 96 89 85 81 76 97 49
3500 3 100 104 99 96 89 84 79 74 97 49
3500 4 101 105 99 96 89 83 79 74 97 50

Performance shown is for installation type D: Ducted inlet, Ducted outlet. The sound power level ratings shown are in decibels, referred to 10-12 watts calculated per
AMCA standard 301. Values are shown for inlet LwiA sound power levels for installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end
correction.

Plymovent representative
TIN_TEV-3110-60_081216_USCA

TEV-/US,CA/3/8
mounting instruction

To have a safe installation and ensure optimal functioning please follow these instructions:

Plymovent recommends you use a duct isolator on both the inlet and outlet of the ventilator.
Plymovent also recommends to use fan mounting vibration isolators on the fan itself as well as on the mounting plate (if used).

The outlet direction of a fan can be changed, we recommend this is done by Plymovent in order to ensure operational performance.
Please contact Plymovent in order to ensure correct working point and blast direction while it is possible to alter the fan's blast orientation in the field,
doing so may void factory warranty. The Plymovent TEV ventilators can be mounted in many different ways, to ensure an optimal functioning and not to
damage other items it is highly recommended to install the ventilator on a flat surface area for all fixing points. The fixing points must be strong enough
(see weight in the technical description part of this manual). Next to this a safety switch is recommended in the installation (not included), always turn
the safety switch to off and disconnect all power if inspection or service is needed on the ventilator.

Soft connection on outlet.

Square to round outlet.

Ventilator motor mounting plate can be rotated


to fit different stations. This is to be done by Ply-
movent, please contact Plymovent for additional
information.
Soft connection on inlet.

Adjustable motor stand,


(not all modells).

Vibration absorber (must be included)


Preferably also place vibration isolators
under the flat installation area / panel

Vibration absorber (must be included)


Preferably also place vibration isolators under
the flat installation area / panel Flat installation area (must
be provided)

TEV-/US,CA/4/8
Alternative mounting examples/recommendations

TEV-/US,CA/5/8
Safety Information

1. The safety net must be mounted to the inlet of the fan prior to use.
2. Connection onto the electrical system may only be carried out by certified electricians.

NOTE! it is prohibited to interfere with the above safety precautions.

Accessories TEV-series fans Accessory list August 2003

Prod. no. Art. no. Description


TOL-250 7390-1011 Transition for ducted outlet.
Outlet transition. Modify from rectangular to round.
TOL-315 7392-1011
Fabricated in galvanized sheet metal.
TOL-400 7394-1011
Outlet transition. Outlet for TEV-3.
TOL-500 7396-101
Outlet transition. Outlet for TEV-5.
Outlet transition. Outlet for TEV-7.
Outlet transition. Outlet for TEV-9
SC-160 7440-1011 Ductwork isolator.
Inlet and outlet vibration isolator. Fabricated in neopreem
SC-200 7441-1011
rubber. Complete with adjustable hose clamps.
SC-250 7442-1011
Inlet and outlet vibration isolator. 160 mm / 6 5/16”
SC-315 7443-1011
Inlet and outlet vibration isolator. 200 mm / 7 7/8”
SC-400 7444-1011
Inlet and outlet vibration isolator. 250 mm / 9 27/32”
SC-500 7445-1011
Inlet and outlet vibration isolator. 315 mm / 12 13/32”

Inlet and outlet vibration isolator. 400 mm / 15 3/4”

Inlet and outlet vibration isolator. 500 mm / 19 11/16”

TEVAV-35 7465-1011 Fan mounting vibration isolator.


Fabricated in neopreem rubber.
TEVAV-79 7467-1011
Fan mounting vibration isolator. For TEV Housing 3 and 5.
Fan mounting vibration isolator. For TEV Housing 7 and 9.
TEV-VHD 7462-1011 Angle support for TEV-5 series fans.
To be used together with mounting vibrators.

TEV-/US,CA/6/8
SPARE PART DRAWING

© Copyright 2008:All rights reserved.All information within this printed matter may not be reproduced,
The energy saving ventilator- TEV handed over, copied, xeroxed or translated into another language in any form or means without written
permission from plymovent Ab. plymovent Ab reserves the right to make design changes.

4.
2.

1.

3.

TEV-/US,CA/7/8
BSAB No: T3.1
SPARE PARTS LIST Ser. No:TEV / RR
Date: Aug -07
Replace: Mar -03

€ Copyright: All right reserved. All information within this printed matter may not be reproduced,
The Energy saving Ventilator- TEV handed over, copied, xeroxed or translated into another language, in any form or any means without
written permission from PlymoVent AB. PlymoVent AB reserves the right to make design changes.

Produkt No: Decription


A All models All models of TEV
B TEV-359-60
C TEV-3110-60
D TEV-559-60
E TEV-585-60
F TEV-745-60
G TEV-768-60
H TEV-798-60
I
Abreviations
X = Order as requiered, state requiered length.

Pos Art. No: A B C D E F G H I Description Note


1 537415-DM-USA 1 Impeller 315/59-5/8"
537803-DM-USA 1 Impeller 315/110-5/8"
537365-DM-USA 1 Impeller 400/59-1 1/8"
537340-DM-USA 1 Impeller 400/85-1 3/8"
537464-DM-USA 1 Impeller 500/45-1 3/8"
537829-DM-USA 1 Impeller 500/68-1 5/8"
537852-DM-USA 1 Impeller 500/98-1 5/8"
2 539 577 1 Inlet spigot 200
539 551 1 Inlet spigot 200
539 627 1 Inlet spigot 250
539 643 1 Inlet spigot 250
539 668 1 Inlet spigot 315
539 692 1 Inlet spigot 315
539 718 1 Inlet spigot 315
3 537 027 1 1 Motor plate 56C
537 035 1 1 Motor plate 184TC
537 043 1 1 1 Motor plate 213TC/ 215TC
4 705 056 1 Electric motor 2HP
705 044 1 Electric motor 3HP
705 058 1 Electric motor 5HP
705 045 1 Electric motor 7,5HP
705 046 1 Electric motor 10HP
705 047 1 Electric motor 15HP
705 048 1 Electric motor 20HP

W hen ordering spare parts please quote:


€Product No. (see label) € Batch No € Description € Part No € Quantity
For example: TEV-359-60, 00040, impeller, 537415-DM-USA, 1 pc

CE declaration of conformity for machinery


We, Plymovent, Kopparbergsgatan 2 SE-214 44 Malmö
Sweden, herewith declare, on our own responsibility, that
the product(s):
TEV-3110, 359, 559, 585, 745, 768, 798
which this declaration refers to, is in accordance with the
conditions of the following Directives:
- Machine Directive 2006/42 EC
- EMC 2004/108 EC
- LVD 2006/95 EC

Alkmaar, the Netherlands, March 15, 2010 C.J.M. Knijn


Chief Operations Officer

TEV-/US,CA/8/8

Potrebbero piacerti anche