Diagnostic Systems Olympus is a precision technology leader,
designing and delivering innovative solutions in
Electrical Requirements: Olympus Diagnostic Systems provides
healthcare and consumer electronics worldwide.
Electrical Consumption: 3.8 KVA
Current: 30 Amp
innovative solutions that meet the high
productivity demands of hospitals, integrated Chemistry Analyzer
health delivery networks, reference labs, blood Olympus works collaboratively with its
Circuit: Dedicated noise free
banks, pharmaceutical and research labs. customers and its parent company, Tokyo-
Voltage: 208/220 VAC [±10%] single phase
Frequency: 60 Hz (within ± 1 Hz)
based Olympus Corporation, to leverage
Ground Requirements: Resistance < 100 ohms Olympus offers the broadest line of random R&D investment in precision technology
Location: Power cable length 10 m access chemistry analyzers, along with lab and manufacturing processes across diverse
automation systems, blood bank analyzers and business lines.
Environmental Requirements:
reagents. Olympus’ solutions save laboratories These include:
Average Heat Output: 9076 BTU/Hr.
time, maximize productivity and deliver fast, • Gastrointestinal endoscopes, accessories and
Ambient Temperatures: 18 ~ 32 °C (fluctuations during
    analysis shall be within ± 2 °C) reliable results. minimally invasive surgical products
Ambient Humidity: 40 ~ 80% RH (No condensation) • Advanced clinical and research microscopes
Water Consumption: 28 L/hour average
To learn more, visit: • Lab automation systems, chemistry,
Water Type: Deionized CAP Type II, bacteria free immunoassay and blood bank analyzers
www.olympusamerica.com/diagnostics
Supply: Continuous flow and reagents
Resistivity: Less than 2.0 µS/cm filtered with a 0.5 µm filter • Digital and film camera, and digital voice
Pressure: 7 - 57 psi Our Service Mission recorders
Control: Shut off valve within 30 ft. The Diagnostics service team is committed to
Drain Requirements: setting the standard for the Healthcare industry In the U.S. and Canada, Olympus serves
Waste: Floor drain maximum height 4” from floor in customer service, product support and the healthcare, scientific and commercial
Dimensions: development of lasting customer relationships. laboratory markets with integrated product
• Overall: 76” W x 41” D x 50.4” H Our goal is to challenge the status quo and instill solutions and financial, educational and
• Analyzer: 49.2” W x 36.6” D x 50.4” H
• Sampler: 26.4” W x 41” D x 37.8”H world class “Total Quality” in every aspect of consulting services that help customers
• Weight: 1,323 lbs our organization. efficiently, reliably, safely, and easily
Optical Characteristics: achieve superior results. Olympus is the
Photometer: Concave diffraction grating as the leader in gastrointestinal endoscopy and
dispersive element
clinical and educational microscopes.
Light Source: Tungsten-halogen lamp
Photometric Modes: Monchromatic or bichromatic
The company’s market-leading consumer
Wavelengths: 340, 380, 410, 450, 480, 520, 540, 570, 600, 660,
electronics business spans North and
  700, 750, 800 nm South America.
Light Path: 6 mm
Photodetector: Silicone photodiode array (built-in
  preamplifier)
Photometric Range: 0~3.0 Abs (light path length Olympus America Inc.
converted to 10 mm) 3500 Corporate Parkway
Photometric Sensitivity: 0.0001 Abs PO Box 610
Data Processor: Center Valley, PA 18034-0125
Interface: RS232C, bidirectional
Tel: 1.800.223.0125
Patient Storage:
• Sample number: 100,000 samples www.olympusamerica.com
• Reaction data: 200,000 tests
AU680BROV1 08.01

Data Input: Keyboard, mouse, touchscreen monitor ©2008 Olympus America Inc. All rights reserved. Printed in the United States of America. OLYMPUS, SUPPORTVISION® and AU®
are registered trademarks of Olympus Corporation, Olympus America Inc. or their affiliated entities. No part of this publication
FROM THE NAME YOU TRUST in
Laboratory Efficiency
Display: 19” touchscreen monitor
may be reproduced and distributed without the express written permission of Olympus America Inc.
Printer: Color laser
Operating System: Windows XP ®
Windows® and Windows XP® are registered trademarks of Microsoft Corporation.
FROM THE NAME YOU TRUST in Laboratory Efficiency...
The Olympus family of chemistry analyzers can exceed productivity
Flexibility
Flexibility
standards in your lab with a host of features that cut operating costs
and speed turnaround time. Every analyzer is designed to help you
manage costs and improve efficiency.
reliability
reliability

… beyond the basics. Real-World Efficiency Improved safety:


Sample probe has clot detection and auto clot
• Fast random access response From specimen loading to
clearing. Both sample and reagent probes have
final result
• Consolidated expansive test menu: crash prevention to safeguard results and
Convenient, bar-coded, ready-to-use liquid
Minimized sample volume: maximize instrument uptime.
High precision microsampling probe
reagents that are standardized across all
enables sampling that conserves
Easier communications:
Olympus instruments. Bi-directional real-time and batch mode
valuable pediatric and geriatric
• Process tests on demand: host communications via an RS232C
samples.
With true STAT interrupt and primary tube serial interface.
Primary tube sampling:
sampling, including pediatric cups. Fully
3, 5, 7 and 10 mL tubes and pediatric
Programmable: Start-up and maintenance.
automated HbA1c option available.
microcups.
• Olympus customer-tailored options:
Automates specimen handling, reagent
Mixed bar-code handling:
Reads multiple standard codes.
management and maintenance.
Fast STATs:
Expansive Test Menu: 22-position STAT carousel with
Consolidated testing for all real-time data display.
clinical chemistry laboratories True walk away capability:
• Routine chemistries 150-sample continuous feed rack loader.
• Urine chemistries Intelligent automation:
• STATs Abnormal sample results are handled
• Electrolytes automatically. Laboratory-definable
• Therapeutic Drug Monitoring options for reflex, repeat, pre-dilution,
• Drugs of Abuse auto-QC, auto-calibration and multi-lot
• Specific Proteins advanced calibration.
• Esoteric Tests
Simplicity and Efficiency Reagent tracking and management:
Including reagent name, on-board stability,
User-friendly Windows® software: lot number, cartridge number,
Reduce training time with customized and expiration date.
menus, icons and color-keyed graphics
Advanced calibration:
Single screen system check: Stores up to five calibration curves per test.
At-a-glance graphic for monitoring
temperature, reagents and system status. Financial Services:
Olympus Financial Services® delivers
Customized user menu: solutions that enable all Olympus customers
Step-by-step guide simplifies training to acquire and utilize the entire portfolio of
and standardizes operation. Olympus products and services through
On-board data management: unique, market-leading financial programs.
Store and search patient files. Data Leveraging the experience of tenured
can also be saved for off-line analysis professionals, Olympus financial service
and archiving. solutions consistently provide value to our
customers to assist them in serving their
Timesaving QC:
Olympus Reagents Minimized reagent usage:
Ultra-efficient spot photometric optics Westgard multi-rule monitoring, twin
communities, patients and customers
with leading technology through
Simple, economical and easy to use and precision dispensers enable reaction plotting for systematic trends and QC
arrangements that meet their
volumes as low as 120 µL. review of daily and day-to-day variations
Ready to use: Liquid formulations budgetary and cash flow objectives.
through Levey-Jennings charts.
packaged in bar-coded cartridges for Open reagent system allows users to Training:
drop-in convenience. program parameters for customized
CLIA compliance: Olympus is dedicated to providing a
Operator login and multi-level password
Increased capacity: special tests comprehensive educational experience
protection, edit with comments
When one cartridge is empty the analyzer preparing laboratorians to adapt to the
Web-Based solutions: for documentation, electronic
automatically switches to the next serial advancing technologies driving improvements
The Olympus Partner Advantage™ Program maintenance logs.
cartridge, performing auto-calibration in the healthcare industry. This is
where the power of partnership allows
and auto-QC. On-line operator’s manual and video: accomplished through innovative teaching
you to be more successful in today’s
Maintenance videos reinforce training. methods designed to engage students
Flexible packaging: demanding lab environment. A unique
Integrated operator’s manual features quick through the use of instructor led and
Most Olympus reagents are packaged in suite of web-based products and services
links, searches and bookmarks. internet-based training.
multiple kit sizes. designed to improve performance, efficiency
and productivity in your laboratory through a Remote diagnostics:
Reagent usage monitoring:
single PC workstation. Olympus SUPPORTVISION®, a web-based
Reagent inventory capability tracks and
service, communicates to Olympus Technical
predicts your daily needs and usage. Middleware solutions: Services for detailed virtual on-site support.
Middleware solutions automate and
standardize the many steps required to
release results to the LIS.

simple
simple
streamlined
streamlined
General Characteristics: ISE Module:
Test Menu Applications: >125 Analytical System: Vertical block flow ion selective

Olympus AU680 System Overview


electrode cell
On-board Parameters: 60 measured tests + 3 ISEs
Analytical Tests: Na, K, Cl
On-board Pre-programmed tests: 100
Sample Throughput: 200 per hour
Maximum Tests/Hour: 800 photometric tests/hr and
1,200 tests/hr with ISE Precision reagent micro High-quality permanent Max Tests/Hr: 600 tests per hour when processing
probe delivers 15 to 250 µL glass cuvettes reduce ISE tests only
Analytical System: Fully automated random access
chemistry analyzer of reagent per test, in 1µL disposable costs. Sample Type: Serum, plasma, urine
increments.
Methods: Sample Volume: 20 µL serum, 20 µL urine
• Endpoint Final Dilution Ratio: 1:32.4 (serum), 1:32.4 (urine)
• Endpoint with self blanking Expedited repeat and
• Endpoint with sample blanking Low maintenance mix bars reflex lane. Measuring Range:
• Kinetic are coated with a highly   Serum and plasma:
• Fixed rate    Sodium 50 - 200 mEq/L
resistant fluoropolymer resin
• ISE    Potassium 1 - 10 mEq/L
for high performance and ease High-precision
  Chloride 50 - 200 mEq/L
Sample Processing Selection: Single, multiple or profile of care. microsampling from 1 to
  Urine:
Sample Volume: 1.6-25 µL in 0.1 µL steps (1-25 µL for repeats)
25 µL, in 0.1 µL increments,    Sodium 10 - 400 mEq/L
with level detection, clot    Potassium 2 - 300 mEq/L
Sample Type: Serum, plasma, whole blood (HbA1c), urine, CSF
detection and probe crash   Chloride 25 - 400 mEq/L
Sample Tray Capacity: 150 samples by rack, 22 position prevention.
STAT carousel Electrode Composition:
Sodium Crown-ether membrane
Sample Container: Potassium Crown-ether membrane
• 12 x 75 – 16 x 100 mm tubes Chloride Molecular oriented PVC membrane
• 3, 5, 7, 10 mL primary collection tubes Reference Liquid on liquid membrane
• Nested micro sample cup
Sample Transport: 10 position bar code racks Installation Requirements:
Large on-board reagent
STAT Sample Transport: Up to 22 positions user-definable for compartments provide 60 R1 wall
  STAT, QC, Cal, routine samples
and 48 R2 reagent positions Min. 20”
Sample Quality Analysis: in a refrigerated and light-
• Lipemia, Hemolysis, Icterus Proprietary precision optics
• Clot detection
protected enclosure.
• Probe crash protection feature Olympus-exclusive
spot photometry for optimum 36.6" 41”
Sample Identification: Bar code reader [Maximum of 26 digits]
photometric readings and
Sample Bar Code Formats: NW7, CODE 39, CODE 128, greater precision.
ISBT-CODE 128, 2 of 5 interleaved, 2 of 5 standard. 2 of 5 is the
specified digit number. Mixed readable (maximum of 4 types at Min. 20” 49.2” 26.4” Min. 20”
the same time) 76”
Long-life ISEs come with a Min. 116”
Reagent Identification: Bar code reader
six-month warranty.
Reagent Configuration: Normal strength and concentrated
Reagent Volume: R1. 15-120 µL; R2. 15-250 µL; STAT module provides
(in 1 µL increments)
Reagent Delivery: One, two or three reagents, probe dispensed
one-button immediate STAT
interrupt. On-board calibrator
Standardized Technology
     with probe crash prevention
Reagent Storage: 4 - 12 °C
and QC storage for system Better results…greater productivity
access during auto-
Hospital lab, core lab, commercial lab…single or multiple
Reagent Bottle Capacity: 15, 30, 60, 120 mL bottles calibration and auto-QC.
locations, Olympus meets your needs with its family of
Reagent Storage Capacity: R1 = 60 positions, R2 = 48 positions standardized chemistry analyzers…greater efficiency…
Reaction Mixture: 120–425 µL at speeds ranging from up to 400 to more than 6,000
150-sample continuous rack tests per hour.
Reaction Temperature: 37 °C loader maximizes walk-away
• Standardized with the same reliable results and

maximize
Reaction Incubation Method: Dry bath capacity. reference ranges.
Reaction Cell: Permanent square glass cuvette (inside

maximize
• Standardized with the same consolidated, expansive
dimension 5x6 mm) test menu.
Reaction Time: 8 minutes, 33 seconds • Standardized with the same reagents, calibrators, controls,
Repeat Run: Automatic with sample volume increase consumables and parts.
or reduction

walk
walkaway
• Standardized to provide reduced cross-training time

away
Reflex Testing: User defined and greater ease of operation with common Windows®
user interface.
Sample Pre-dilution: Dilution factors of
       3, 5, 10, 15, 20, 25, 50, 75, 100 fixed