Sei sulla pagina 1di 2

iMAG 4700

Mechanical Quick Start Guide


Components

Power/Output Cable
(DC configuration)

Cable Glands
15 Pin Connector
(DC configuration)

Meter and Security Seal


Indicator

Optional

Protective faceplate Output Cable Second Output


cover and lanyard (Battery Cable (DC
configuration) configuration)

Recommended Tools
Recommended: Optional:

• T-15 Torx head driver • Channel locks


• 0.098 inch (small) flat head screw driver
• Crescent Wrench

253.872.0284 seametrics.com
iMAG 4700
Mechanical Quick Start Guide

Positioning
Choose a position that will ensure a full pipe. Choose a position that will minimize flow distortion.
5X 1X

2X 1X

5X 1X

Recommended: Intermittent air


Not Ideal: Intermittent air
bubbles pass
Improved accuracy bubbles miss electrode Air bubbles and over electrode
results from sediment on the
Electrode moved from
unimpeded electrodes top by rotating meter
electrodes can affect
accuracy
Possible
Electrodes free from sediment
sediment build-up build-up

Grounding
Metal Pipe Plastic Pipe
Meter Flange Equalization Lug
Gasket Grounding Ring Grounding Ring
Pipe Flange Gaskets Gaskets
Equalization Lug Lockwasher
Flange Plate
Plastic Plastic
Pipe Pipe
Ground Clamp
(Exothermically weld when
corrosion is a concern)

Meter
Flange Pipe Earth
Flange
#6, #8, or #12 AWG Stranded 8’ Ground Rod
Metal Pipe Gaskets Metal Pipe Copper Ground Wire < 5’

Warnings Refer to instruction manual for further details.

• This meter is sensitive to heat. Do not weld or flame cut within • Tube must be completely aligned with adjoining flanges.
10’ of meter. Heat will damage electronics and liner. (Heat will
• Bolts must be tightened evenly. Do not over tighten one side
void warranty.)
to fill a gap.
• It is highly recommended that full face gaskets be installed on
• Improper sealing of cables or cable glands will void warranty.
each end of the meter to protect the liner. (Damage to liner
will void warranty.) • Install security seal during installation if regulations require.

Refer to the Electrical Quick Start Guide or the complete instruction manual for details on wiring.

Seametrics • 19026 72nd Avenue South • Kent, Washington 98032 • USA LT-14267r1.4 20161111
(P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • seametrics.com 11/11/16