Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
The reactor effluent chiller for MTBE units is one such exam-
ple. In this case study, retrofitting a Alfa Laval Packinox reac-
tor effluent chiller into an MTBE unit enhanced efficiency by
further cooling reactor effluent after the chiller drum.
Reactor effluent
Propane from
refrigeration system
Chiller knock-out
drum vapors
Design information
Overall length: 7m
Bundle cross-section: 3.5m x 2.5m
Design pressure: 11 bar.g
Design temperature: -10°C / 45°C
This heat exchanger can serve in similar operations which call for
multi-stream service requiring both cross-flow and counter-flow
configurations.
273606_PCT00075EN:251765_packinox_multi-stream_PPM00118 14/05/07 13:56 Side 2
PPI00198EN 0705 Alfa Laval reserves the right to change specifications without prior notification.