Sei sulla pagina 1di 7

Page-1

SOLAR DC SURFACE PUMPS

Data Sheet For Solar DC Surface Pumps

MBP-30 Solar DC Surface Pumps, Model : MBP-30, Rated Head:10 Mtr., 1.0 HP, Shut off head 12 Mtr.

MBP-60 Solar DC Surface Pumps, Model : MBP-60, Rated Head:10 Mtr., 2.0 HP, Shut off head 12 Mtr.

MBP-90 Solar DC Surface Pumps, Model : MBP-90, Rated Head:10 Mtr., 3.0 HP, Shut off head 15 Mtr.

MBP-90 HD Solar DC Surface Pumps, Model : MBP-90 HD, Rated Head:20 Mtr., 3.0 HP, Shut off head 25 Mtr.

MBP-30 MBP-60 MBP-90 MBP-90 HD


Rated head (mtr.) 10 10 10 20
3
Discharge (M /Hr.) 12.8 25.7 38.5 19.2
12 12 15 25
900 Wp 1800 Wp 2700 Wp 2700 Wp Water output figures are on a clear
sunny day with 3 times tracking of
Input Voltage (Vmp.) > 30 V > 60 V > 90 V > 90 V SPV panel when solar radiation on
Input Max. Current 25 Adc horizontal surface is 7.15 KW/sq.m/day
(i.e. coplanar with PV module)

Stander Test Condition : AM=1.5,


SP/6N-0120 25/2012/ E=1000W/m2 ,Cell Temperature : 25°C
/0130/2013 WP/SEC

Rotosol's DC Surface pumps are the most efficient and reliable solution for conditions
where the suction head is limited to 7 meters. Surface pumps are of mono block
construction with the impeller mounted directly on the motor shaft. The motor uses
high energy permanent magnets and rare earth magnets to achieve very high
efficiency.

Polyurethane Impact resistance


paint for long life water canopy

High efficiency
casting using no
back process

Bronze neck ring


for high suction lift

Mc4 wether proof


connector

Investment SS Shaft High flux Quick & easy


cast impeller permanent magnet brush replacement
(Life long warranty) in 2 minutes

Rev.-0 (Jan.-2016-2017)
Page-2
Specifications of Solar DC Surface Pumps
Label on Pump

Model MBP-30 MBP-60 MBP-90 MBP-90-HD

Voltage 30 VDC 60 VDC 90 VDC 90 VDC

Current 25 Amp 25 Amp 25 Amp 25 Amp

Max. Head 12 Mtr 12 Mtr 15 Mtr. 25 Mtr.

Suction Head 7 Mtr 7 Mtr 7 Mtr 7 Mtr

Suction Pipe 2” 2.5” 3” 3”

Delivery Pipe 1.5” 2.5” 3” 3"

Dimensions of Solar DC Surface Pumps


B

D
C

E
MBP-30 461 266 113 126 117 2”X1.5" 300 Wp 3 0030
MBP-60 531 294 113 126 191 2.5”X2.5” 300 Wp 6 0060
MBP-90 536 328 128 156 215 3”X3” 300 Wp 9 0090
MBP-90 - HD 536 328 128 156 215 3”X3” 300 Wp 9 0090-HD

Preferred Solar PV Array

300 Wp, 72 Cell


900 W
38.88 V
44.56 V

7.71 A
8.48 A

3 Parallel 2 Series - 3 Parallel 3 Series - 3 Parallel


900 Wp 1800 Wp 2700 Wp

Rev.-0 (Jan.-2016-2017)
Page-3
Performance characteristics of MBP-30 (No. :- 0030)

30 V 25 V 20 V

1000
I/P Power (Watt)

800
600
400
200
0
0 2 4 6 8 10 12 14 16 18 20
Discharge (M3/hr)

18
16
14
Total Head (Mtr.)

12
10
8
6
4
2
0
0 2 4 6 8 10 12 14 16 18 20
3
Discharge (M /hr)

70%
60%
50%
Efficiency (%)

40%
30%
20%
10%
0%
200 300 400 500 600 700 800 900
I/P Power (Watts)

These curves are at 7 meter suction (Including friction loses) tested as per IS-5120-1977

Rev.-0 (Jan.-2016-2017)
Page-4
Performance characteristics of MBP-60 (No. :- 0060)

60 V 55 V 50 V

2000
I/P Power (Watt)

1500

1000

500

0
0 5 10 15 20 25 30 35 40 45 50
3
Discharge (M /hr)

16
14
Total Head (Mtr.)

12
10
8
6
4
2
0
0 5 10 15 20 25 30 35 40 45 50
3
Discharge (M /hr)

50%

40%
Efficiency (%)

30%

20%

10%

0%
400 600 800 1000 1200 1400 1600 1800
I/P Power (Watts)

These curves are at 7 meter suction (Including friction loses) tested as per IS-5120-1977

Rev.-0 (Jan.-2016-2017)
Page-5
Performance characteristics of MBP-90 (No. :- 0090)

90 V 85 V 80 V

3000
I/P Power (Watt)

2500
2000
1500
1000
500
0
0 5 10 15 20 25 30 35 40 45 50
3
Discharge (M /hr)

30

25
Total Head (Mtr.)

20

15

10

0
0 5 10 15 20 25 30 35 40 45 50
3
Discharge (M /hr)

70%
60%
50%
Efficiency (%)

40%
30%
20%
10%
0%
500 1000 1500 2000 2500 3000

I/P Power (Watts)

These curves are at 7 meter suction (Including friction loses) tested as per IS-5120-1977

Rev.-0 (Jan.-2016-2017)
Page-6
Performance characteristics of MBP-90 (No. :- 0090-HD)

90 V 85 V 80 V
3000
I/P Power (Watt)

2500
2000
1500
1000
500
0
0 10 20 30 40 50 60
Discharge (M3/hr)

30

25
Total Head (Mtr.)

20

15

10

0
0 10 20 30 40 50 60

Discharge (M3/hr)

50%

40%

30%
Efficiency (%)

20%

10%

0%
500 1000 1500 2000 2500 3000
I/P Power (Watts)

These curves are at 7 meter suction (Including friction loses) tested as per IS-5120-1977

Rev.-0 (Jan.-2016-2017)
Page-7
Surface Pumps Packing Dimensions & Weight

W
H L

Approx.
L W H packing
Model
(mm) (mm) (mm) weight
(kgs)

MBP-30 35

MBP-60 580 280 400 55

MBP-90 & MBP-


67
90-HD

Rev.-0 (Jan.-2016-2017)