FINAL RECONCILATION OF SUPPLY ITEMS (POWER DISTRIBUTION, PART-B, PACKAGE NO. B-05B)

S.N. DESCRIPTION UNIT QTY ACTUAL ACTUAL WASTA BALANC deviation REMARK
SUPPLIED ERECTIO GE/ E
AT SITE N AT SITE SCRAP

A. POWER DISTRIBUTION
1.0
6.6/0.433 kV LCSS TRANSFORMERS
1.1
6.6/0.433 kV, 1000 kVA, dry
No. 6 6 6 - nill 0
type, cast resin, AN transformer
1.2
6.6/0.433 kV, 1600 kVA, dry
No. 6 6 6 - nill 0
type, cast resin, AN transformer
1.3
6.6/0.433 kV, 800 kVA, dry type,
No. 2 2 2 - nill 0
cast resin, AN transformer
1.4
6.6/0.433 kV, 1000 kVA, oil
No. 2 2 2 - nill 0
immersed, ONAN transformer
1.5
6.6/0.433 kV, 1600 kVA, oil 02 nos transformers for CHP is
No. 8 6 6 - nill 0 stored in Mecon store
immersed, ONAN transformer
2.0
DC SYSTEM - 0
2.1
220V, 500 AH battery bank 01 set CHP battery bank installed in
Set 3+ 1 3+ 1 4 - nill 0 AHP
(VRLA, SMF type)
2.2 1/2 board for CHP is stored in Mecon
220 V, Battery Charger system Set 3+ 1 3+ 1 3 +1/2 - nill 0 store
2.3
220 V DC, Distribution Board 01 no DC distribution board for
Set 3+ 1 3+ 1 3 - nill 0 CHP is stored in Mecon store
3.0
local push button stations walls
near LCSS transformers 02 nos Push button taken MBPL through
No. 24 22 22 - nill 0 Mecon/ Nalco

Page 1 of 9 TRICOLITE
TRICOLITE ELECTRICAL INDUSTRIES LTD

FINAL RECONCILATION OF SUPPLY ITEMS (POWER DISTRIBUTION, PART-B, PACKAGE NO. B-05B)

S.N. DESCRIPTION UNIT QTY ACTUAL ACTUAL WASTA BALANC deviation REMARK
SUPPLIED ERECTIO GE/ E
AT SITE N AT SITE SCRAP

4.0
CABLE TERMINATION/JOINTING KITS
1 Cx630 sq. mm (Indoor type) Set 56 56 54 - 2 0
1 Cx630 sq. mm (Outdoor type) Set 18 18 18 - nill 0
1 Cx500 sq. mm (Indoor type) Set 120 120+2 122 - nill 2
3 Cx185 sq. mm (Indoor type) 01 No jointing kit taken by WPIL
Set 50 50 44 - 5 0 through Mecon/ Nalco
3.5 C x 300 sq.mm Set 20 20 - - 20 0
3.5 C x 240 sq.mm Set 2 2 - - 2 0
3.5 C x 185 sq.mm Set 6 6+61+7 74 - nill 61 07 taken from NALCO
3.5 C x 120 sq.mm Set 4 4 4 - nill 0
3.5 C x 95 sq.mm Set 2 2+6 8 - nill 0 06 nos used of 2cx 120sqmm
3.5 C x 70 sq.mm Set 10 10+7 17 - nill 0
07 nos taken from Nalco &
Used in 3.5 x 50 sqmm
3.5 C x 50 sq.mm Set 20 20+58 78 - nill 41 17 nos used of 3.5 x70 sqmm
3.5 C x 35 sq.mm Set 10 10 10 - nill 0 10 Nos Used in 4CX16
3.5 C x 25 sq.mm Set 15 15 15 - nill 0 15 Nos Used in 4cx16 sqmm
4 C x 16 sq.mm 277 Local purchesed + 40 nos
30+277+4
Set 30 372 - nill 242 taken from Nalco + 25 used of
0+25 3.5x 25sqmm & 3.5X 35 sqmm

4 C x 10 sq.mm 40Nos used in 7cx 2.5 sqmm +


Set 100 100 - - 26 0 34 nos used in 2cx16 sqmm
cable
2 C x 120 sq.mm Set 14 14 - - 8 0 06 nos used in 3.5x95sqmm
2 C x 10 sq.mm Set 200 200 152 - 18 0 30 nos used in 5CX2.5 Sqmm
2 C x 4 sq.mm Set 36 36 - - nill 0 36 Nos Used in 3CX 2.5 SQMM
Page 2 of 9 TRICOLITE
TRICOLITE ELECTRICAL INDUSTRIES LTD

FINAL RECONCILATION OF SUPPLY ITEMS (POWER DISTRIBUTION, PART-B, PACKAGE NO. B-05B)

S.N. DESCRIPTION UNIT QTY ACTUAL ACTUAL WASTA BALANC deviation REMARK
SUPPLIED ERECTIO GE/ E
AT SITE N AT SITE SCRAP

2 C x 70 sq.mm Cu, Set 18 18+16 34 - nill 16


37 C x 2.5 sq.mm Set 12 12 - - 12 0
27 C x 2.5 sq.mm Set 20 20 - - 20 0
19 C x 2.5 sq.mm Set 30 30 18 - 12 0
14 C x 2.5 sq.mm Set 50 50 32 - 18 0
10 C x 2.5 sq.mm Set 50 50 84 - nill 34
7 C x 2.5 sq.mm Set 50 50 90 - nill 40
5 C x 2.5 sq.mm Set 80 80 110 - nill 0 30 nos used of 2cx10 sqmm
3 C x 2.5 sq.mm Set 50 50 120 - nill 34 36 nos Used of 2cx 4 SQMM
2 C x 2.5 sq.mm Set 200 200 200 - nill 0
1 C x 2.5 sq.mm (unarmoured,) Set 2000 2000 1,820 - 180 0
2 C x 2.5 sq.mm (unarmoured,) Set 200 200 190 - 10 0
6
600 mm Ladder trays
1317.5 meter taken Smelter
M 5000 5000 3,352.5 - 205 0
&125 mtr O&M department
450 mm Ladder trays M 400 400 - - 400 0
300 mm Ladder trays 37.5 mtr taken ATLAS Through
M 400 400 270 - 92.5 0 Mecon
150 mm Ladder trays M 300 300 46.5 - 254 0
90 bends for 600 mm tray No. 40 40 40 - nill 0
90 bends for 450 mm tray No. 10 10 - - 10 0
90 bends for 300 mm tray No. 6 6 6 - nill 0
90 bends for 150 mm tray No. 4 4 4 - nill 0
Horizontal Tee for 600 mm tray No. 40 40 40 - nill 0
Horizontal Tee for 450 mm tray No. 10 10 - - 10 0
Page 3 of 9 TRICOLITE
TRICOLITE ELECTRICAL INDUSTRIES LTD

FINAL RECONCILATION OF SUPPLY ITEMS (POWER DISTRIBUTION, PART-B, PACKAGE NO. B-05B)

S.N. DESCRIPTION UNIT QTY ACTUAL ACTUAL WASTA BALANC deviation REMARK
SUPPLIED ERECTIO GE/ E
AT SITE N AT SITE SCRAP

Horizontal Tee for 300 mm tray No. 6 6 - - 6 0


Horizontal Tee for 150 mm tray No. 4 4 - - 4 0
7
600 mm perforated cable trays M 600 600 89 - 511 0
450 mm perforated cable trays M 300 300 30 - 270 0
300 mm perforated cable trays M 200 200 70.5 - 130 0
150 mm perforated cable trays M 200 200 200 - nill 0
90 bends for 600 mm tray No. 20 20 8 - 12 0
90 bends for 450 mm tray No. 6 6 3 - 3 0
90 bends for 300 mm tray No. 4 4 4 - 0 0
90 bends for 150 mm tray No. 2 2 2 - nill 0
Horizontal Tee for 600 mm tray No. 20 20 - - 20 0
Horizontal Tee for 450 mm tray No. 6 6 3 - 3 0
Horizontal Tee for 300 mm tray No. 4 4 1 - 3 0
Horizontal Tee for 150 mm tray No. 2 2 2 0 0
75 x 10 mm GI Strip M 1200 1200+100 1,300 3 nill 100
65 x 8 mm GI Strip M 600 600 596.5 3.5 nill 0
50 x 6 mm GI Strip M 1600 1600 1,587 13 nill 0
25 x 3 mm GI Strip M 200 200 200 - nill 0
10.0
ASHLOK make Earting System
No. 44 44 43 - 1 0 for CHP TRANSFORMERUNIT (9 &10)
of Type T-39
150 mm diameter GI Pipe M 60 60 60 - nill 0
100 mm diameter GI Pipe M 60 60 60 - nill 0
50 mm diameter GI Pipe M 220 220 220 - nill 0

Page 4 of 9 TRICOLITE
TRICOLITE ELECTRICAL INDUSTRIES LTD

FINAL RECONCILATION OF SUPPLY ITEMS (POWER DISTRIBUTION, PART-B, PACKAGE NO. B-05B)

S.N. DESCRIPTION UNIT QTY ACTUAL ACTUAL WASTA BALANC deviation REMARK
SUPPLIED ERECTIO GE/ E
AT SITE N AT SITE SCRAP

250 mm diameter HDPE PIPE M 20 20 20 - nill 0


200 mm diameter HDPE PIPE M 10 10 10 - nill 0
150 mm diameter HDPE PIPE M 10 10 10 - nill 0
13
Fire Sealing Compound M3 4 4 4.0 - nill 0
14
600 mm GI tray cover M 200 200 200 - nill 0
450 mm GI tray cover M 50 50 50 - nill 0
300 mm GI tray cover M 50 50 50 - nill 0
150 mm GI tray cover M 50 50 50 - nill 0
15.0
415 V, 3 phase, 250 A Switch
No. 3 3 - - 3 0
Fuse Unit
B.
ILLUMINATION
1.1
RCWPH LDB Set 1 1 1 - nill 0
1.2
AHP LDB Set 1 1 1 - nill 0
1.3
HCSD LDB, Set 1 1 1 - nill 0
2.1
SLDB, Type-A Set 3 3 3 - nill 0
2.2
SLDB, Type-B Set 4 4 4 - nill 0
2.3
SLDB, Type-C Set 9 9 9 - nill 0
2.4
SLDB, Type-D Set 10 10 5 - 5 0
3.0
Receptacle Distribution Board
Set 6 6 6 - nill 0
(RDB)
4.0
DC Emergency Lighting
Set 6 6 6 - nill 0
Distribution Board (DCELDB),
5.0
415 V TPN, 32 A, industrial type
No. 15 15 15 - nill 0
switch socket outlet
Page 5 of 9 TRICOLITE
TRICOLITE ELECTRICAL INDUSTRIES LTD

FINAL RECONCILATION OF SUPPLY ITEMS (POWER DISTRIBUTION, PART-B, PACKAGE NO. B-05B)

S.N. DESCRIPTION UNIT QTY ACTUAL ACTUAL WASTA BALANC deviation REMARK
SUPPLIED ERECTIO GE/ E
AT SITE N AT SITE SCRAP

6.0
240 V single phase, 20 A
No. 38 38 38 - nill 0
industrial type socket outlet
7.0
20 A MCB controlled with 20A
No. 10 10 - - 10 0
socket outlet
8.0
1400 mm sweep ceiling fan No. 15 15 6 - 9 0
9.0
450 mm exhaust fans No. 6 6 2 - nill 0 04 NOS Taken P&R through Nalco

10.1
250 W, HPSV medium bay, non-
integral type light fitting complete No. 45 45 39 - 6 0
10.2 ith W, t HPSV
250 l l
street light fitting
complete with control gear, lamp, No. 150 150 148 - 2 0
10.3 i
150 W, HPSV t street light fitting
complete with control gear, lamp, No. 40 40 39 - 1 0
10.4 i
70 W, HPSV t non integral type
well glass fitting complete with No. 50 50 nill 0
50 -
10.5
250 W HPSV non-integral type
flood light fittings complete with No. 20 20 20 - nill 0
10.6
control gear lamp accessories
250 W HPSV non-integral type
flood light fittings complete with No. 40 40 40 - nill 0
control gear, lamp, accessories,

Page 6 of 9 TRICOLITE
TRICOLITE ELECTRICAL INDUSTRIES LTD

FINAL RECONCILATION OF SUPPLY ITEMS (POWER DISTRIBUTION, PART-B, PACKAGE NO. B-05B)

S.N. DESCRIPTION UNIT QTY ACTUAL ACTUAL WASTA BALANC deviation REMARK
SUPPLIED ERECTIO GE/ E
AT SITE N AT SITE SCRAP

10.7
200 W, well glass DC emergency
No 60 60 45 - 15 0
light fittings complete with GLS
10.8
60 W, decorative recessed type
No. 12 12 - - 12 0
DC emergency light fittings
10.9
240 V, fluorescent luminarie
decorative, mirror optic type No. 48 48 + 3 51 - nill 0 03 nos taken TRICOLITE from Nalco

reflector suitable for 2x40 W


10.10
240 V, fluorescent luminarie
decorative, mirror optic type
reflector suitable for 2x40 W No. 8 8 - - 8 0
lamps complete with electronic
choke, starter, etc
10.11
240 V, fluorescent industrial
luminarie suitable for 2x40 W
No. 250 250 198 - 52 0
lamps complete with electronic
choke, starter, etc
10.12
240 V, corrosion proof
fluorescent industrial luminarie
No. 12 12 10 - 2 0
suitable for 2x40 W lamps
complete with electronic choke,

Page 7 of 9 TRICOLITE
TRICOLITE ELECTRICAL INDUSTRIES LTD

FINAL RECONCILATION OF SUPPLY ITEMS (POWER DISTRIBUTION, PART-B, PACKAGE NO. B-05B)

S.N. DESCRIPTION UNIT QTY ACTUAL ACTUAL WASTA BALANC deviation REMARK
SUPPLIED ERECTIO GE/ E
AT SITE N AT SITE SCRAP

10.13
HPSV non integral type
asymmetrical beam flood light 05 nos taken NALCO for cable yard
fittings with HID 2x400W tubular No. 48 48 43 - nill 0 lighting
HPSV lamps complete with
11.0 t l
swaged i
steel tubular t road
No. 150 135 135 - nill 0
lighting pole 10 Mtr height
12.0
swaged steel tubular area
No. 40 20 19 - 1 0
lighting pole 10 Mtr height
13.0
415 V TPN sheet steel enclosed
junction box with 1 set of 63 A
No. 5 5 4 - 1 0
incomer terminal and 2 sets of 32
A outgoing terminal blocks
25 mm GI conduit 120 meter local purched & 400meter
M 3000 961+ 120+ 40 2,961 - nill 120 from S.C sahoo
19 mm GI conduit M 300 300 291 9 nill 0
Light point for control of two
No. 16 16+11 27 - nill 11 11nos local purched
lamps with one switch
Light point for control of one lamp
No. 4 4+ 45 49 - nill 45 42 nos local puched
with one switch
Light point for control of one
No. 5 5+9 14 - nill 9 09 nos local purched
ceiling fan and regulator with one
Socket point for control of 5 A No. 6 6+10 16 - nill 10 10 nos local purched
50 sq.mm stranded GI wire M 300 300 - - 300 0
16 sq.mm mm stranded GI wire M 250 250 250 - nill 0
6 sq.mm stranded GI wire M 800 800 Page 8 of 9
800 - nill 0 TRICOLITE
TRICOLITE ELECTRICAL INDUSTRIES LTD

FINAL RECONCILATION OF SUPPLY ITEMS (POWER DISTRIBUTION, PART-B, PACKAGE NO. B-05B)

S.N. DESCRIPTION UNIT QTY ACTUAL ACTUAL WASTA BALANC deviation REMARK
SUPPLIED ERECTIO GE/ E
AT SITE N AT SITE SCRAP

3 sq.mm stranded GI wire M 3000 3000 3,000 - nill 0


8 SWG GI wire M 6000 6000+757 6,757 - nill 757 757 local purched
14 SWG GI Wire M 2000 2000 2,000 - nill 0
17.0
30 mtr. High, G.I. High Mast No. 2 2 2 - nill 0
18.0
T-19 Safe Electrode 3 mtr long No. 26 26 23 - 3 0 for CHP TRANSFORMERUNIT (9 &10)
19.0
push button station consisting of
Cast Iron Box, two nos. push
button for ON/OFF, 2NO+2NC No. 10 10 3 - 7 0
contacts,

20.0
timer control panel consisting of 1
No. 125 A MCCB, 125 A No. 5 5 3 - 2 0
contactor, timer, Auto/manual
21.0
Supply of Insulating Mat of Sq.M
50 50 45.5 - 5 0
suitable Voltage grade. tr.

Page 9 of 9 TRICOLITE