Sei sulla pagina 1di 6

Connection b/w concrete Waler Beam beam & Splay

465
Design Axial Force (N) = 1.5 x 1652.966 kN
2479.4 kN
Width of the plate (W) = 465 mm
Length of the plate (L) = 920 mm
Thickness of the plate (t) = 30 mm 800
Bolt design check 920
Nominal diameter of Bolt (d) = 32 mm
Hole diameter (d0) = 32 +2
= 34 mm
Grade of bolt = Fe 500D 100 150 100
fub = 565 Mpa (Refer Table 1 of IS 800:2007) gmb = 1.25 (Refer Table 5 of IS 800:2007)
fup = 500 Mpa ( for plate material)
Net Area of bolt (An) = 0.78×3.141×32.0^2/4
= 627 mm2

Design strenth of the bolt (Vdsb) = (fu (nn Anb + ns Asb) / 3) / gmb (As per clause: 10.3.3 of
= 163.7 kN IS:800-2007)

(As per clause: 10.3.4 of


Design bearing strength of the bolt (Vdpb) = (2.5* kb* d* t* fup)/gmb IS:800-2007)

Edge distance of bolt ( e ) = 60 mm


Pitch distance of bolt (p) = 150 mm
kb is smaller of = e/ 3d0 p/3d0-0.25 fub / fup 1.0
= 0.6 1.22 1.13 1.0
= 0.6
Design bearing strength of the bolt (Vdpb) = 564.7 kN

Bolt Value = 163.7 kN


No of bolts required (Nr) = 2479.4 / 163.7
15 nos
No of bolts provided (Np) = 16 nos Safe
Check for Anchorage of Bolt as per ACI 318-08

A Steel Strength in Shear


Steel Strength in Shear = f Vsn Eqn No D-19
= f n Ase futa (Refer Clause D.6.1, Appindix -D of ACI 318-08)

Edge Distance (Ca1) = 350 mm


3x Ca1 = 1050 mm > 800 mm

As per D.1, Appendix D of ACI -318-08


No of Bolts acting as a group (n) = 16

Grade of bolt = Fe 500D


fub = 565 Mpa (Refer Table 1 of IS 800:2007)
f= 0.65 (refer D.4.4(a)ii of ACI )
f Vsn = 3685 kN > 2479.4 kN
Safe

B Concrete Breakout Strength


Concrete Breakout Strength = f Vcbg Eqn No D-22
= f (Avc/Avc0) yec yed yc yh Vb

Avc = (1500) x1.5 Ca1


= 787500 mm2
Avco = 4.5 x C2a1 Eqn No D-23
= 551250 mm2
2 2
n Avco = 8820000 mm > 787500 mm
Safe
ev' = 0 mm
yec = 1/ (1+ 2ev' / 3Ca1) from D.6.2.5
= 1.00

yed = 1.0 from D.6.2.6


yc = 1.0 from D.6.2.7
yh = 1.0 from D.6.2.8
for hef > 1.5Ca1
Embedment Legth of bolt (hef) = 1000 mm > 525 mm

Vb = 7 (le/d)0.2 da l fc' Ca11.5 Eqn No D-24

le = 8 da hef
256 1000
= 256 mm
Grade of Concrete in capping Beam = M35
Characteristic strength of Concrete (fc') = 35 Mpa
= 5 ksi
= 5000 psi
l = 1.0 from D.8.6
Vb = 44462.93 lb
f= 0.85 (refer D.4.5(c)i of ACI )

Concrete Breakout Strength = 53990.7 lb


= 246.4 kN

Shear per Bolts = Vu /n


= 154.966 kN < 246.4 kN
Safe
C Concrete Pryout
Concrete Pryout Strength = f Vcpg Eqn No D-31
= f kcp Ncbg
f= 0.7 (refer D.4.4(c)i of ACI )
kcp = 2.0 for hef > 2.5 in
Ncbg = (ANc/ANc0) yec yed yc ycp Nb

ANc = (1500) (350+3hef)


= 5025000 mm2
ANco = 9.0 x h2ef Eqn No D-6
= 9000000 mm2
yec = 1.0 from D.5.2.4
yed = 0.7+0.3(Ca,min/1.5hef) from D.5.2.5
= 0.77
yc = 1.0 from D.5.2.6
ycp = 1.0 from D.5.2.7
Nb = 24 l fc' hef1.5 Eqn No D-7
429325.052 lb

Concrete Pryout Strength = 258403.6 lb


= 1179.1 kN

Shear per Bolts = Vu /n


= 154.966 kN < 1179.1 kN
Safe
Connection b/w concrete Waler Beam beam & Steel Strut
940
Design Axial Force (N) = 1.5 x 297.15 kN
445.7 kN
Width of the plate (W) = 940 mm
Length of the plate (L) = 810 mm
Thickness of the plate (t) = 30 mm 500
Bolt design check 810
Nominal diameter of Bolt (d) = 20 mm
Hole diameter (d0) = 20 +2
= 22 mm
Grade of bolt = Fe 500D 700
fub = 565 Mpa (Refer Table 1 of IS 800:2007) gmb = 1.25 (Refer Table 5 of IS 800:2007)
fup = 500 Mpa ( for plate material)
Net Area of bolt (An) = 0.78×3.141×20.0^2/4
= 245 mm2

Design strenth of the bolt (Vdsb) = (fu (nn Anb + ns Asb) / 3) / gmb (As per clause: 10.3.3 of IS:800-
= 63.9 kN 2007)

(As per clause: 10.3.4 of IS:800-


Design bearing strength of the bolt (Vdpb) = (2.5* kb* d* t* fup)/gmb 2007)

Edge distance of bolt ( e ) = 115 mm


Pitch distance of bolt (p) = 150 mm
kb is smaller of = e/ 3d0 p/3d0-0.25 fub / fup 1.0
= 1.7 2.02 1.13 1.0
= 1.0
Design bearing strength of the bolt (Vdpb) = 600.0 kN

Bolt Value = 63.9 kN


No of bolts required (Nr) = 445.7 / 63.9
7 nos
No of bolts provided (Np) = 8 nos Safe
Check for Anchorage of Bolt as per ACI 318-08

A Steel Strength in Shear


Steel Strength in Shear = f Vsn Eqn No D-19
= f n Ase futa (Refer Clause D.6.1, Appindix -D of ACI 318-08)

Edge Distance (Ca1) = 500 mm


3x Ca1 = 1500 mm > 500 mm

As per D.1, Appendix D of ACI -318-08


No of Bolts acting as a group (n) = 8

Grade of bolt = Fe 500D


fub = 565 Mpa (Refer Table 1 of IS 800:2007)
f= 0.65 (refer D.4.4(a)ii of ACI )
f Vsn = 720 kN > 445.7 kN
Safe

B Concrete Breakout Strength


Concrete Breakout Strength = f Vcbg Eqn No D-22
= f (Avc/Avc0) yec yed yc yh Vb

Avc = (1500) x1.5 Ca1


= 1125000 mm2
Avco = 4.5 x C2a1 Eqn No D-23
= 1125000 mm2
2 2
n Avco = 9000000 mm > 1125000.0 mm
Safe
ev' = 0 mm
yec = 1/ (1+ 2ev' / 3Ca1) from D.6.2.5
= 1.00

yed = 1.0 from D.6.2.6


yc = 1.0 from D.6.2.7
yh = 1.0 from D.6.2.8
for hef > 1.5Ca1
Embedment Legth of bolt (hef) = 600 mm < 750 mm

Vb = 7 (le/d)0.2 da l fc' Ca11.5 Eqn No D-24

le = 8 da hef
160 600
= 160 mm
Grade of Concrete in capping Beam = M35
Characteristic strength of Concrete (fc') = 35 Mpa
= 5 ksi
= 5000 psi
l = 1.0 from D.8.6
Vb = 60019.31 lb
f= 0.85 (refer D.4.5(c)i of ACI )

Concrete Breakout Strength = 51016.4 lb


= 232.8 kN

Shear per Bolts = Vu /n


= 55.716 kN < 232.8 kN
Safe
C Concrete Pryout
Concrete Pryout Strength = f Vcpg Eqn No D-31
= f kcp Ncbg
f= 0.7 (refer D.4.4(c)i of ACI )
kcp = 2.0 for hef > 2.5 in
Ncbg = (ANc/ANc0) yec yed yc ycp Nb

ANc = (1500) (150+3hef)


= 3750000 mm2
ANco = 9.0 x h2ef Eqn No D-6
= 3240000 mm2
yec = 1.0 from D.5.2.4
yed = 0.7+0.3(Ca,min/1.5hef) from D.5.2.5
= 0.87
yc = 1.0 from D.5.2.6
ycp = 1.0 from D.5.2.7
Nb = 24 l fc' hef1.5 Eqn No D-7
199532.253 lb

Concrete Pryout Strength = 280207.3 lb


= 1278.6 kN

Shear per Bolts = Vu /n


= 55.716 kN < 1278.6 kN
Safe