7‐D er Timer (Internal Relay)
Day Digittal Geyse
 
Rated V
Voltage: 220
0‐240V AC  Max 20 0A (3500 WWatts) 
16 Proggrammable Settings  Resistiive Load Ge
eyser) 
15‐Day Backup Batttery  Max 10 0A (Inductive Load) 
IEC 607
730 Rated  DIN Raail Mounted d 

 
OPEERATING IN NSTRUCTION NS 
 Apply 2220V to Livee (L) terminaal and Neuttral (N) term
minal on tim
mer. 
 Wait for 20 second ds, then pussh recessed Reset button. Timer w will reset. 
 Push Clock button once. Program 1 is now set. 
 For timer to operate automattically press MANUAL b button until ON AUTO appears on n screen. 
 To operrate timer mmanually prress MANUA AL button u until ON or O
OFF appearrs on screen n. 
 Supply to the Geysser elementt is switched d on when tthe ON LED D is on. 
 
To sswitch betw
ween 12h an nd 24h mod de push andd hold the Clock button n until AM d displays (12h) or not (24h). 
   
SETTING DAY & TIME 
 Push and hold Clock button. 
 Push D+ repeatedly to adjust Day. 
 Push H+ repeatedly to adjust Hour. 
 Push M+ to adjust Minute. 
 Release Clock button. Time and Day is set. 
 
PROGRAMMING TIMER 
 Push P button once (Program 1 ON appears). This will set the time when the Geyser element should 
switch ON. 
o Push D+ repeatedly until desired day is reached (various combinations of days are available). To 
set for all days at once press until all 7 days are displayed (top of display). 
o Push H+ repeatedly until desired hour is reached. 
o Push M+ repeatedly until desired minute is reached. 
 
 Push P button once again (Program 1 OFF appears). This will set the time when the Geyser element 
should switch OFF. 
o Push D+ repeatedly until desired day is reached (various combinations of days are available). To 
set for all days at once press until all 7 days are displayed (top of display). 
o Push H+ repeatedly until desired hour is reached. 
o Push M+ repeatedly until desired minute is reached. 
 
 When finished press the Clock button to exit the programming mode. 
 
PROGRAM EXAMPLES 
 
To set Geyser element backup to switch on from 05:00 to 06:00 in the morning: 
 Push P button once (Program 1 ON appears). 
o Select all days by pushing D+ repeatedly until all 7 days are displayed. 
o Set ON time to 05:00 
 Push P button once again (Program 1 OFF appears). 
o Set OFF time to 06:00 
 
To also set Geyser element backup to switch on from 18:00 to 19:00 in the afternoon: 
 Push P button until Program 2 ON appears. 
o Select all days by pushing D+ repeatedly until all 7 days are displayed. 
o Set ON time to 18:00 
 Push P button once again (Program 2 OFF appears). 
o Set OFF time to 19:00 
 
 16 Programs can be set. 
 This means it is possible to set various Geyser backup times for each or different days of the week. 
 
 