Country NIGERIA
Strategic Partner ZTE
Date of Installation 2018/03/25
Date of Integration 2018/03/25
Date of Commissioning 2018/03/25
Sign Sign
Name Name
Date : Date :
Drive Test Data:
Planned Actual Remarks
Site ID: 49114 49114
Site Name: LG9114 LG9114
Site Configuration (2/2/2 , 4/4/4…) : 4/4/4 4/4/4
Activity (New Site / Swap) Swap Swap
BTS
BTS Type : ( Indoor
Product Type : / Outdoor / Tower Top / IBS Micro ) Indoor Indoor
Mention - Flexi / Ultra etc For NSN BS8900A BS8900A
Site Address: 2964 / RBS 2954 etc for Ericsson
Mention - RBS Dangote Cement, Oba Akran Avenue, Ikeja
Region : LAGOS
Latitude : 6.611
Longitude : 3.33456
1ST FLOOR Yes
GPRS Working ( Yes / No ) 2ND FLOOR Yes
3RD FLOOR Yes
1ST FLOOR Yes
Edge Working ( Yes / No ) 2ND FLOOR Yes
3RD FLOOR Yes
1ST FLOOR 4
No. Of Dynamic EDGE TSL allocated 2ND FLOOR 4
3RD FLOOR 4
Cell Configuration
GSM900/1800 (in case dual band antenna is installed) or
GSM1800 (incase single GSM1800 antenna is installed) 1ST FLOOR 2ND FLOOR 3RD FLOOR Sector 4
Mention Yes / No
For BTS Cabinets Yes
For all Cables & Accessories Yes
Labelling done for All BSS and TX equipments For Tx Equipment Yes
Installed For GSM Antenns Yes
For MW Antennas Yes
For TMA's NA
For Fiber Equipment Yes
For Mux Eqpt NA
Fibre Connectivity :
Is the Site with OFC Node Connectivity ? (Yes / No ) NO
Agency from which OFC Node is provided (Mention
BTSOL/PGCIL/Railtel etc )
Type of OFC MUX (Mention STM 1/ STM 4 etc)
Attach Prediction Plots (Annexure 1) Yes/No Soft copy along with candidate to be given by D&P Yes
Attach Drive Test Report (Annexure 2) Yes/No To be Given within one 7 days of Site RFS Yes
Attach Walk Test Report for IBS Yes/No To be Given within one 7 days of Site RFS Yes
Coverage Certified to be in line with Prediction Yes/No To be Given within one 7 days of Site RFS Yes
Remarks
NOTE:
Functionality test should be perform at the static point under good RF condition. Please ensure the following criterias accordingly:
1. Within main lobe of the respective sector that closest to the site.
2. Dominant RxLev.
3. RxLev should be greater then -85dBm.
4. RxSub should be greater than -9.
Remarks
Sector 4
Sector 4
Sector 4
Sector 4
Sector 4
Actual
Remarks
Link4
Actual
Test Pass /
Fail
Drive Test Plots comparisons will be made at -85 signal strength Level . This includes Swap Comparisons and Prediction vs. Actual Drive Test Comparison.
Annexure 2: Drive Test plot with Radius Marked for -85dBm and -93 dBm
Sector 2
Sector 3
Traffic CS
CSSR
TCH Congestion
SDSR (%)
SDCCH Congestion
Sector 3 Photograph