Specifications, designs and other content appearing in this brochure are current as of October 2006 but subject to change without notice. Printed on 100% recycled paper with soy ink.
The match for
tastefully designed offices and stores. CEILING SUSPENDED TYPE
Simple design and quiet
operation
Auto-swing airflow brings
comfort to each and every
corner of the room.
Installation and
maintenance are easy.
Cooling only
HP 2 2.5 3 4 5 6 6.5 7
apacity *
1
Btu/h 18,000 21,000 26,000 36,000 42,000 48,000 51,000 56,000
values given for kW 5.3 6.2 7.6 10.6 12.3 14.1 15.0 16.4
–6 HP is for FHC type,
HP–7 HP is for FDMG type. kcal/h 4,560 5,290 6,550 9,100 10,600 12,100 12,900 14,100
EILING MOUNTED
ASSETTE TYPE
Indoor unit FHC18NUV1 FHC21NUV1 FHC26NUV1 FHC36NUV1 FHC42NUV1 FHC48NUV1
Outdoor unit R18NUV1 R21NUV1 R26NUV1 / Y1 R36NUV1 / Y1 R42NUY1 R48NUY1
950 mm
B lade
21NU 35 dB 30 dB
26NU 35 dB 30 dB
36NU 42 dB 36 dB
42NU 42 dB 36 dB
950 mm
48NU 42 dB 36 dB
Optimal comfort and convenience assured by three blow modes Quick and easy to install
Blow direction Draft prevention setting Standard setting Setting to prevent soiling of ceiling
Sound level
Desired situation When drafts are unwanted For gentle drafts(Ceiling is soiled.) When ceilings must be kept spotless Just 240 mm thick. Installable
Cooling only
FHC18NU–48NU
42/ 36 High
FHC36NU
Low
dB Auto-swing
Blow direction
can be set to
Auto-s wing between
10° and 40°
S ettable to 5 different
levels between
Auto-s wing between
10° and 65°
S ettable to 5 different
levels between
Auto-s wing between
30° and 65°
S ettable to 5 different
levels between
under low-lying beams (18NU—26NU)
240 mm *1 245 mm *2
(220V) 5 levels 10° and 40° 10° and 65° 30° and 65°
Draft prevention At heating s tartup and thermo OFF*, air blow is auto- At heating startup and ther-
mo OFF*, air blow is auto-
(In heating mode) matic ally s et to a near horizontal 10˚ to prevent direc t matically set to 30˚ to prevent both direct expo-
expos ure to c ool air drafts . sure to cool air drafts and contact with ceilings.
*1 298 mm thic k with 36NU– 48NU
Auto blow The las t blow direc tion is s aved in memory and automatic ally s et the next time the unit is
direction control turned ON. (Fac tory s etting is 65˚ for heating and 30˚ for c ooling.) *2 303 mm thic k with 36NU– 48NU
Option Note: B low direc tion is s et to the s tandard pos ition when the unit is s hipped from the fac tory.
Easy height adjustment
Accessory required for indoor unit The pos ition c an be c hanged from the remote c ontroller.
*When the thermos tat turns off.
Each corner of the unit has an
Wired LCD remote controller Multi-Flow System Wide air distribution Adjuster Pocket that
lets you easily adjust
4-way blow A newly shaped air discharge
the unit's suspended
BRC1C61 1 pattern opening increases flow without
height.
increasing wind speed. Discharged
3-way blow
air reaches farther than before. Note: If the wireless remote
Note: R emote c ontroller c able not 4 pattern c ontrol option is installed,
inc luded. C ables must be Air blow distribution comparison a light rec eptor unit is
•42NU (m)
proc ured loc ally. Super Cassette 3.2
housed in one of the ad-
(m) Conventional model 3
2.7 2.5 m/sec
2.0 m/sec
2.5 m/sec All models suspended
2 2
Wireless LCD remote controller 2-way blow 1.5 m/sec 2.0 m/sec without lift
3 pattern 1 1.0 m/sec 1.5 m/sec
A s ignal rec eiver mus t be added to the indoor unit. 1.0 m/sec 1
0.5 m/sec 0.5 m/sec
BRC7C613W " " denotes piping direction. " " denotes sealing
member for air discharge outlet (option) . 4 (m) 3 2 1 0 1 2 3 4 (m)
90° rotating
Note: For 3-way or 2-way blow ins tallation, the
air intake grille
s ealing member for air dis c harge outlet
(option) mus t be us ed to c los e off the
Installable on high ceilings
Signal receiver unit
unus ed outlet(s ). Criteria for ceiling height and number of Ins talled in
(Installed type) blow outlets any direc tion.
Blow direction can be selected Number of blow outlets used
Wireles s remote c ontroller and s ignal according to installation. 18NU–26NU 36NU–48NU
rec eiver unit are s old as a s et. 4-way 3-way 2-way 4-way 3-way 2-way
blow blow blow blow blow blow
Provided with drain water
Note: Operation nois e
Standard 2.7 m 3.0 m 3.5 m 3.2 m 3.6 m 4.2 m
inc reas es when Ceiling
High ceiling 3.0 m 3.3 m 3.8 m 3.6 m 4.0 m 4.2 m
us ing 2-way
or 3-way
height
High ceiling 3.5 m 3.5 m - 4.2 m 4.2 m - lift-up mechanism
Features Note: Fac tory s ettings are for s tandard c eiling
height and 4-way blow. High c eiling s ettings
Mildew
Feature Comfort prevention Work & Servicing Control features 1 and 2 are s et with the remote
Easy installation of options
C eiling s oiling prevention
Program "Dry"
Mold res is tant treatment
High c eiling applic ation
S wing pattern s elec tion
Dehumidification is computer
Ultra long-life filter
Drain water lift-up
Both indoor unit and wired remote controlled to prevent abrupt and
Two s elec table
thermo-s ens ors
Long-life filter
Filter s ign
screwdriver.
for filter
3 4
CEILING SUSPENDED TYPE FH-NU
Upgrade to an quiet and compact system.
Spreads comfortable air throughout the room Quiet operation
Quiet operation has been
Auto-swing (up&down) Installable on ceilings emphasized even more on the
brings comfort to the room. 3.5 m high exposed ceiling suspended type unit.
(220V)
Option
Accessory required for indoor unit 50°
30 mm 1,590 mm 30 mm
S witc hable fan s peed
similar environments.
Timer s elec tor
Program "Dry"
the case.
Auto-res tart
Auto s wing
drain pan
Cooling only • • • • • • *1
• •
*1Applic able to R 36NU– R 48NU outdoor units
5 6
DUCT CONNECTION DUCT CONNECTION
MIDDLE STATIC PRESSURE TYPE FDMG-NU LOW STATIC PRESSURE TYPE FDBG-NU
Unit can be mounted in the Ideal for quiet, beautiful living
ceiling and air can be delivered spaces
freely by duct. Suitable for condominiums and
Superior freedom of layout apartments, houses and hotels,
and similar living areas
The duct system allows the most efficient location
of discharge outlets in accordance with the room
layout Handy
Medium static pressure type, usable in a larger Small, lightweight, and easy-to-install outdoor unit.
than standard space
Duct connection is simpler with standard rear Quiet operation
intake chambers (220V)
Durable
Quiet operation
(220V)
To achieve increased durability by improved resistance to
Daikin units are salt corrosion and atmospheric pollution, coated PE fins (with
Indoor unit High LOW
among you can get. special acryl pretreatment) are used for the heat exchanger
FDMG26NU 42 dB 38 dB of the outdoor unit.
Noise is less likely
FDMG36NU 45 dB 37 dB
to detract from the
comfort provided by FDMG42NU 46 dB 37 dB
air conditioning. FDMG48NU 46 dB 37 dB
FDMG51NU 47 dB 37 dB
Sound level FDMG56NU 47 dB 37 dB Sound level or more
Cooling only
FDMG26NU—56NU 45/ 37dB
High
FDMG36NU
Low
Switchable fan speed: High/Middle/Low
Drain pipe connection can be done inside the unit. Coolant
Cooling only
FDBG18NU—26NU 43/ 40dB
High
FDBG26NU
Low
[Duc t c onnec tion]
Air filter
S uc tion c hamber
(220V) and drain pipe outlets are at the same opening. (220V) To prevent increased operation noise, avoid installing the air suction grille
directly below the suction chamber.
Option Accessory required for indoor unit Option Accessory required for indoor unit
Features
Features
Digital remote Remote Feature Comfort Work & Servicing Control features Digital remote Remote
Feature Comfort Work & Servicing Control features Others
controller controller controller controller
S witc hable fan s peed
up to 10 m
Auto-res tart
KRC47-2 KRC47-1
Model KRC47-2A KRC47-1A Model
KRC47-4 Cooling only • *1
• KRC47-4A
*1Applic able to R 36NU– R 51NU outdoor units Cooling only • • • •
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
When air conditioning two rooms Door-installed Wall-installed
Under-door cutout
simultaneously, the air discharged into ventilation grille ventilation grille
each room must be circulated back to the
air conditioner. To ensure this, a
Ventilates air through
ventilation duct should be installed for Partitioning wall
the partitioning wall.
each room or one of the indicated (S ee right)
ventilation grilles should be installed on the Ventilation grille Ventilation grille Under-door c utout
partitioning wall or under the door
Note: The under-door cutout method should be used only when there is a small volume of air flow.
between the rooms.
7 8
OUTDOOR UNIT Abundance of functions that provide comfortable
air-conditioning in stores and offices.
See the list of main functions given on the page introducing each indoor unit.
C omfort W o r k a n d S e r v ic in g
Auto-swing Drain water lift-up mechanism
Delivers comfortable air- Air discharge direction angle can Steeper gradient ensures more
conditioning to all areas, be set (fixed setting) efficient wastewater drainage.
near to and far from the air- High-lift is especially useful for
conditioner. long lengths of drain piping.
quiet operation with minimal gas and fits in the same space R21NU 10 m 30 m 15 m
Program "Dry" C o n t r o l fe a t u r e s
(Equivalent length 50 m)
turbulence. as previous outdoor units. Dehumidification is computer controlled to prevent abrupt and
30 m
R26NU 10 m (Equivalent length 50 m) 20m
uncomfortable changes in air temperature. Useful for reducing Auto-restart
discomforting humidity without uncomfortable cooling of the
Fitted with Super Aero Grille R36NU 15 m 30 m
(Equivalent length 50 m) 20 m
room.
If there is a power outage while the equipment is operating,
(Applies to R26NU–51NU) R42NU 15 m 30 m 20 m operations will restart in the same mode as before the power
(Equivalent length 50 m)
To suppress cut when electricity is restored.
R48NU 15 m 30 m
(Equivalent length 50 m) 20 m High-ceiling application
turbulence and Delivers air-conditioning comfort all the way down to the floor
30 m
achieve quiet 50 R51NU 15 m 20 m
in air-conditioning zones with high ceilings.
Others
(Equivalent length 50 m)
9 10
CEILING MOUNTED CASSETTE TYPE DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
18 21 26 36 42 48 26 36 42 48 51 56
Indoor unit FHC18NUV1 FHC21NUV1 FHC26NUV1 FHC36NUV1 FHC42NUV1 FHC48NUV1 Indoor unit FDMG26NUV1 FDMG36NUV1 FDMG42NUV1 FDMG48NUV1 FDMG51NUV1 FDMG56NUV1
Model Model
Name R26NUV1 R36NUV1 Name R26NUV1 R36NUV1
Outdoor unit R18NUV1 R21NUV1 R42NUY1 R48NUY1 Outdoor unit R42NUY1 R48NUY1 R51NUY1 R56NUY1
R26NUY1 R36NUY1 R26NUY1 R36NUY1
Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Cooling capacity 1a/1b Btu/h 18,100/18,000 21,200/21,000 26,300/26,000 36,500/36,000 42,700/42,000 49,100/48,000 Cooling capacity 1a/1b Btu/h 26,300/26,000 36,500/36,000 42,700/42,000 49,100/48,000 52,200/51,000 57,000/56,000
kW 5.3/5.3 6.2/6.2 7.7/7.6 10.7/10.6 12.5/12.3 14.4/14.1 kW 7.7/7.6 10.7/10.6 12.5/12.3 14.4/14.1 15.3/15.0 16.7/16.4
kcal/h 4,580/4,560 5,340/5,290 6,630/6,550 9,200/9,100 10,800/10,600 12,400/12,100 kcal/h 6,630/6,550 9,200/9,100 10,800/10,600 12,400/12,100 13,200/12,900 14,400/14,100
Power consumption 1a/1b kW 2.03/2.02 2.46/2.45 3.07/3.07 4.04/4.04 4.79/4.79 5.49/5.49 Power consumption 1a/1b kW 3.15/3.15 4.16/4.16 4.84/4.84 5.55/5.55 5.90/5.90 6.45/6.45
Colour Unit ---------- Colour ----------
Indoor Indoor
Decoration panel White Fan Air flow rate (H) m3/min 23 37 42 42 42 42
unit unit
Air flow rate (H) m3/min 15 19 19 33 33 33 cfm 811 1,306 1,482 1,482 1,482 1,482
cfm 529 670 670 1,164 1,164 1,164 Sound level (H/L) (220V) 2 dBA 42/38 45/37 46/37 46/37 47/37 47/37
Sound level (H/L) (220V) 2 dBA 33/29 35/30 35/30 42/36 42/36 42/36 Dimensions (HX WX D) mm 305X 1,350X 680 305X 1,550X 680 305X 1,550X 680 305X 1,550X 680 305X 1,900X 680 305X 1,900X 680
Dimensions Unit mm 230X 840X 840 230X 840X 840 230X 840X 840 288X 840X 840 288X 840X 840 288X 840X 840 Machine weight kg 43 52 52 52 58 58
(HX WX D) Decoration panel mm 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 Operation range °CWB 14 to 25
Unit kg 24 24 24 28 28 28 Colour Ivory
Machine weight Outdoor
Decoration panel kg 5 5 5 5 5 5
unit Compressor Type Hermetically sealed rotary type Hermetically sealed scroll type
Operation range °CWB 14 to 25 Motor output kW 2.5 3.00 3.75 4.50 4.50 4.50
Colour Ivory white Ivory Refrigerant charge (R22) kg 2.3(Charged for 10 m) 2.0(Charged for 15 m) 2.4(Charged for 15 m) 2.6(Charged for 15 m) 2.7 (Charged for 15 m) 2.8 (Charged for 5 m)
Outdoor
unit Compressor Type Hermetically sealed rotary type Hermetically sealed scroll type Sound level 2, 3 dBA 57 55 57 59 59 56
Motor output kW 1.7 2.2 2.5 3.00 3.75 4.50 Dimensions (HX WX D) mm 770X 900X 320 1,170X 900X 320 1,170X 900X 320 1,345X 900X 320 1,345X 900X 320 1,345X 880X 370
1.20 1.50 2.3 2.0 2.4 2.6 Machine weight kg 70 (V1), 69 (Y1) 81 (V1), 79(Y1) 87 92 93 114
Refrigerant charge (R22) kg (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) °CDB
Operation range 21 to 46
Sound level 2, 3 dBA 49 54 57 55 57 59 Piping Liquid (Flare) mm o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5
Dimensions (HX WX D) mm 540X 750X 270 685X 800X 300 770X 900X 320 1,170X 900X 320 1,170X 900X 320 1,345X 900X 320 connections Gas (Flare) mm o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1 o/ 19.1 o/ 19.1
Machine weight kg 42 61 70 (V1), 69 (Y1) 81 (V1), 79 (Y1) 87 92 Drain Indoor unit mm 3/4B (I.Do/ 21.6X O.Do/ 27.2)
Operation range °CDB 21 to 46 Outdoor unit mm o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole)
Piping Liquid (Flare) mm o/ 6.4 o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 Max. interunit piping length m 30 (equivalent length 50 m) 50 (equivalent length 70 m)
connections Gas (Flare) mm o/ 15.9 o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1 Max. installation level difference m 20 30
Drain Indoor unit mm I.Do/ 25X O.Do/ 32 I.Do/ 25X O.Do/ 32 I.Do/ 25X O.Do/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 Heat insulation Both liquid and gas piping
Outdoor unit mm o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) Note :
Max. interunit piping length m 30 (equivalent length 50 m) 1
Nominal cooling capacities are based on the following conditions:
1a
Max. installation level difference m 15 20 Return air temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
1b
Return air temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
Heat insulation Both liquid and gas piping 2
Anechoic chamber conversion value, measured according to JIS parameters and criteria.
Note : During operation these values are somewhat higher owing to ambient conditions.
3
1
Nominal cooling capacities are based on the following conditions: In case of V1: 220V, Y1: 380V.
1a
Return air temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
1b
Return air temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Anechoic chamber conversion value, measured according to JIS parameters and criteria.
During operation these values are somewhat higher owing to ambient conditions.
3
In case of V1: 220V, Y1: 380V. DUCT CONNECTION LOW STATIC PRESSURE TYPE
18 21 26
Indoor unit FDBG18NUV1 FDBG21NUV1 FDBG26NUV1
Model
Name R26NUV1
CEILING SUSPENDED TYPE Outdoor unit R18NUV1 R21NUV1
R26NUY1
21 26 36 42 48 Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Indoor unit FH21NUV1 FH26NUV1 FH36NUV1 FH42NUV1 FH48NUV1 Cooling capacity 1a/1b Btu/h 18,100/18,000 21,200/21,000 26,300/26,000
Model kW 5.3/5.3 6.2/6.2 7.7/7.6
Name R26NUV1 R36NUV1
Outdoor unit R21NUV1 R42NUY1 R48NUY1 kcal/h 4,580/4,560 5,340/5,290 6,630/6,550
R26NUY1 R36NUY1
Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz Power consumption 1a/1b kW 2.12/2.11 2.73/2.72 3.33/3.33
Colour ----------
Cooling capacity 1a/1b Btu/h 21,200/21,000 26,300/26,000 36,500/36,000 42,700/42,000 49,100/48,000 Indoor
kW 6.2/6.2 7.7/7.6 10.7/10.6 12.5/12.3 14.4/14.1 Air flow rate (H) m3/min 13 18 18
unit
kcal/h 5,340/5,290 6,630/6,550 9,200/9,100 10,800/10,600 12,400/12,100 cfm 458 635 635
Fan Driving system Direct drive (2 speed)
Power consumption 1a/1b kW 2.72/2.71 3.10/3.10 4.06/4.06 4.83/4.83 5.50/5.50
Colour White Sound level (H/L) (220V) 2 dBA 41/38 43/40 43/40
Indoor Dimensions (HX WX D) mm 260X 900X 580 260X 1,300X 580 260X 1,300X 580
Air flow rate (H) m3/min 22-23 22-23 32-34 38-40 42-44
unit Machine weight kg 23 31 31
cfm 776-811 776-811 1,129-1,200 1,341-1,412 1,482-1,553
Operation range °CWB 14 to 25
Sound level (H/L) (220V) 2 dBA 44/40 44/40 46/40 48/42 49/43
Dimensions (HX WX D) mm 195X 1,160X 680 195X 1,160X 680 195X 1,590X 680 195X 1,590X 680 195X 1,590X 680 Colour Ivory white Ivory
Outdoor
Machine weight kg 26 26 35 35 35 unit Compressor Type Hermetically sealed rotary type
°CWB 14 to 25 Motor output kW 1.7 2.2 2.5
Operation range
Colour Ivory white Ivory 1.20 1.50 2.3
Outdoor Refrigerant charge (R22) kg (Charged for 10 m) (Charged for 10 m) (Charged for 10 m)
unit Compressor Type Hermetically sealed rotary type Hermetically sealed scroll type
Motor output kW 2.2 2.5 3.00 3.75 4.50 Sound level 2, 3 dBA 49 54 57
1.50 2.3 2.0 2.4 2.6 Dimensions (HX WX D) mm 540X 750X 270 685X 800X 300 770X 900X 320
Refrigerant charge (R22) kg (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) Machine weight kg 42 61 70 (V1), 69 (Y1)
Operation range °CDB 21 to 46
Sound level 2, 3 dBA 54 57 55 57 59
Dimensions (HX WX D) mm 685X 800X 300 770X 900X 320 1,170X 900X 320 1,170X 900X 320 1,345X 900X 320 Piping Liquid (Flare) mm o/ 6.4 o/ 6.4 o/ 9.5
kg 61 70 (V1), 69 (Y1) 81 (V1), 79 (Y1) 87 92 connections Gas (Flare) mm o/ 15.9 o/ 15.9 o/ 15.9
Machine weight
Operation range °CDB 21 to 46 Drain Indoor unit mm 3/4B (I.Do/ 21.6X O.Do/ 27.2)
Piping Liquid (Flare) mm o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 Outdoor unit mm o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole)
Max. interunit piping length m 30 (equivalent length 50 m)
connections Gas (Flare) mm o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1
Max. installation level difference m 15 20
Drain Indoor unit mm I.Do/ 20X O.Do/ 26 I.Do/ 20X O.Do/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26
Outdoor unit mm o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) Heat insulation Both liquid and gas piping
Max. interunit piping length m 30 (equivalent length 50 m) Note :
1
m 20 Nominal cooling capacities are based on the following conditions:
Max. installation level difference 15 1a
Return air temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
Heat insulation Both liquid and gas piping 1b
Return air temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria.
1
Nominal cooling capacities are based on the following conditions: During operation these values are somewhat higher owing to ambient conditions.
3
1a
Return air temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal). In case of V1: 220V, Y1: 380V.
1b
Return air temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Anechoic chamber conversion value, measured according to JIS parameters and criteria.
During operation these values are somewhat higher owing to ambient conditions.
3
In case of V1: 220V, Y1: 380V.
39
11 40
12
DIME N S ION S (Unit: mm)
C
Decoration panel BYC125K-W1 9
D
E
Sealing member for air discharge outlet KDBHJ55K160 10
950
Direct installation type KDDJ55X160
60
Chamber connection kit2 KKSJ55K160 4-M4 Hole
(prepared hole) 80
High-efficiency filter (Colorimetric method 65%) KAFP556D80 KAFP556D160 6 75
80
(Colorimetric method 90%) KAFP557D80 KAFP557D160
Replacement 7
(Colorimetric method 65%) KAFP552H80 KAFP552H160
160
high-efficiency filter A view 420
(Colorimetric method 90%) KAFP553H80 KAFP553H160 B
For fresh air intake kit
Adjustable(0~550)
High-efficiency filter chamber KDDFP55D160 3 B view connection
[FHC18NUV1-26NUV1] Required space (direct installation type)
Replacement long-life filter KAFJ551K160 55 840 55
295 55 840 55
Ultra long-life filter KAFP55D160 12-M4 Hole
750
80 2 100=200 85 (prepared hole) 1500mm or more
Replacement ultra long-life filter KAFJ55K160H Required space
110
Branch duct chamber KDJ55K80 KDJ55K160
95
1500mm
Remote controller Wired type1 BRC1C61 or more
200
40 A
1500mm
B
150
125
30 10
or more
150
1500mm or more
Wired LCD remote controller with weekly schedule timer BRC1D61 240 260
Branch duct When the discharge grill is closeout,the required space is
1000 or more
Suspension 270 40
Central remote controller2 DCS302CA61 bolt 8 5 4 1
connection 200mm or more.
315 2 350
Unified ON/OFF controller2 DCS301BA61 4-M8 M10
Schedule timer2 DST301BA61 A
intelligent Touch Controller2 DCS601C51 A B C D E
Adaptor for wiring3 KRP1B57 FHC18NUV1-26NUV1 230 240 165 ---- ----
Wiring adaptor for electrical appendices3 KRP4A53 FHC36NUV1-48NUV1 288 298 195 165 195
[FHC36NUV1-48NUV1]
Interface adaptor for SkyAir series DTA102A52 55 840 55
Installation box for adaptor PCB KRP1B98 80 2 100=200 85 14-M4 Hole
(prepared hole)
Note:
155
165
40
50
1
Wiring for wired remote controller to be procured locally. 1 Liquid pipe connection
Notes:
2
This optional accessory requires DTA102A52. 1
Location of unit's Name Plate 2 Gas pipe connection
3
Installation box for adaptor PCB (KRP1B98) is necessary. For Main body: Switch Box Cover inside surface of suction grille. 3 Drain pipe connection
195
For decoration panel: Panel frame inside surface of suction grille. 4 Power supply connection
150
2
When installing an optional accessory, refer to the 5 Remote control code and control wiring connection
CEILING SUSPENDED TYPE installation drawings. Branch duct
Required space
6 Air discharge grille
1000 or more
40 connection
For fresh air intake kit Inspection port is necessary.
Kit name For high efficiency filter unit Inspection port is not necessary.
350 7 Air suction grille
Name of option Remark 8 Port for water supply
FH21NU FH26NU FH36NU FH42NU FH48NU 3
In case of using wireless remote controller, this position will
Replacement long-life filter Resin net be a signal receiver. Refer to the drawing of wireless remote A 9 Corner decoration cover
KAFJ501D80 KAFJ501D160
controller in detail. 10 Drain hose
L-type piping kit (for upward direction) KHFJ5F80 KHFJ5F160
Remote controller Wired type1 BRC1NU61
Wireless type BRC7NU66
Note:
CEILING SUSPENDED TYPE
1
Wiring for wired remote controller to be procured locally.
115 60
135
Remote controller KRC47-1A 18 17 16 142 58
192 36
FH42NUV1 1550 1590
Digital remote controller KRC47-2A FH48NUV1 1550 1590
65
160
40
102
185
210
Digital remote controller for duct heater use KRC47-4A 50 60 65
85
Suction grille KDGF19A45 KDGF19A71
position)
Position slit hole for taking out in piping back
(Hanging
Drain pan cover KKD19A1 127
5
A
(Required space)
(Hanging position)
Kit name
Name of option Remark
FDMG26NU FDMG36NU FDMG42NU FDMG48NU FDMG51NU FDMG56NU Hanging bolt
680 1
Remote controller KRC47-1 4-M8~M10 Position : Hole of wall for taking out in piping back
Digital remote controller KRC47-2 (View from the front)
5
5 11 80
Digital remote controller for duct heater use KRC47-4
195
40
90
155
(Required space)
For height installaion
55
300 or more
13
6 30 or more B 30 or more
(Service space) (Service space) 55 14
4 o/ 45
Outdoor units
Obstacle The Front
Floor side Brand name plate
1 Air discharge grille
(Note.2)
2 Air suction grille
3 Air filter
Kit name 4 Gas pipe connection
Name of option Remark Drain pipe connection VP20
6
R18NU R21NU R26NU R36NU R42NU R48NU R51NU R56NU (For left piping) 5 Liquid pipe connection
Drain piping kit ------- KIS95 ------- 6 Drain pipe conneciton
Central drain plug ------- KKPJ5F180 7 Earth terminal (inside the electric components box) (M4)
300
275
8 Suspension bracket
225
275
9 Backward piping and wiring connection opening lid
80 80 10 Upward piping and wiring connection opening lid
105 11 Right side pipe connection
3 2 7 5 4 12 Left back drain pipe connection
Notes: 170
1 13 Left side drain pipe connection
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.
2 14 Right side drain pipe connection
In case of using wireless remote controller, this position will be a signal receiver.
15 Hole of wall for taking out in piping back
Refer to the drawing of wireless remote controller in detail.
3 16 Upward drain pipe connection
The remote control code is the standard <about 3 m outside the machine> attached.
17 Upward gas pipe connection
(0.5 mm2 2 wicks O.D. 5.4)
18 Upward liquid pipe connection
(It is attached to VRV.)
13 14
DIME N S ION S (Unit: mm)
700
A Holes for anchor bolts
B 151 (M8 or M10) 520
190 60
3-Drain outlets 170 27
300 or more
10 or more
3
290
306
500
237
213
580
48
95
317
271
530 100 34
137
167
72
750 15 270
Service space
8
55
Terminal cover
C 126
(Suspension bolt pinch) Earth
terminal
D (M4)
E
F 2
4 Power intake
540
50
Name
5 plate
Gas stop valve
110
107
170
164
134
228
260
150
219
236
260
52
16
10
G 29 6 7 H I
N
1 16 J Minimum space for air passage Service port
(All around)
O 10 K
(All around) 151 L A
M H Space A
1 Liquid pipe connection 5 Switch box Less than 1000 More than 300
150
50
2 Gas pipe connection 6 Control wiring intake (for remote controller) More than 1000 More than 600
100
3 Drain pipe connection 7 Control wiring intake (for outdoor unit)
4 Ground terminal 8 Suspension bracket Note: 1Location of unit's Name Plate: Chamber cap
H
A
A B C D E F G H I J K L M N O 50
FDBG18NUV1 900 704 755 684 664 3XP150=450 500 127 3XP150=450 674 688 704 900 10-M4 12-M4
Holes Holes
FDBG21NUV1/26NUV1 1300 1104 1155 1084 1064 6XP150=900 700 102 6XP150=900 1074 1088 1104 1300 16-M4 18-M4
Holes Holes 50
A
B 151 300 or more Holes for anchor bolts
3 269
(Suspension bolt pinch)
(M8 or M10)
3
600
31
680
330
350
427
381
146
98
116
Service space
55
51 7XP150=1050
152
5
123
Power intake
212
175
206
274
305
150
305
263
280
Name plate
Liquid
645
G H 29 stop valve
685
1 6 7 Liquid pipe
74
16
10
70
2 Gas pipe connection I
Gas
95
151 J
3 Drain pipe connection stop valve
8 K
4 Ground terminal 16 L 75 100 Gas pipe
5 Switch box 51 M
6 Control wiring intake (for remote controller) A
7 Control wiring intake (for outdoor unit)
8 Suspension bracket
150
305
263
280
H
A B C D E F G H (All around)
150
FDMG26NUV1 1350 1153 1203 1134 1114 7XP150=1050 18-M4 727 I J K L M N
50
100
Holes
FDMG36NUV1/42NUV1/48NUV1 1550 1353 1403 1334 1314 7XP150=1050 18-M4 827 FDMG36NUV1/42NUV1/48NUV1 1550 1353 1337 1321 7XP150=1050 20-M4
Holes Holes
FDMG51NUV1/56NUV1 1900 1703 1753 1684 1664 9XP150=1350 22-M4 827 FDMG51NUV1/56NUV1 1900 1703 1687 1671 9XP150=1350 24-M4 H A
Holes Holes 50
50 H 1000 300
A
H 1000 600
15 16
DIME N S ION S (Unit: mm)
[Space required for outdoor unit installation] (Unit: mm)
REMOTE CONTROLLER Dimensions inside brackets [ ] indicate case where air direction adjustment guide is adjusted downward.
The values represent the case for the R26 type through R56 type.
Wireless type • Remote controller dimensions
For R26NU-56NU The dimensions in ( ) are for the R36 and R56 type (The unit values is mm. )
BRC7C613W CEILING MOUNTED CASSETTE TYPE In case of R56 model, the values in < > are those when the air discharge direction of the grille is downward.
Transmitting part
•Remote controller holder
installation procedure
•Receiver installation procedure • Receiver detail When there is an obstruction When there is an obstruction
<Installation to wall surface> Receiver
Drain piping on the inlet side on the outlet side
side
When the overhead space is open When the overhead space is open
1. For single unit
157
100
100
Remote controller or m
holder ore
re
When there is an obstruction ss
mo or le
100
or m
ore 10
0 or in the overhead space 500
1000 or more
54 18.1 1. For single unit
installation
Receiver detail
2. For series installation
•
106
72
Note :
Do not install more than 3 receivers in (more than two units) or le
ss
the vicinity of one another. 500
With 4 or more units, there is always
1000 or more
the possibility of malfunction
100
0.5 0o
70 18 35 49 rm
(Ceiling opening) ore
Switch box
re An obs truc tion
(field Supplied parts) mo
200 or in the overhead s pac e
or m 0 0)
ore 0(3
20
19
71
38
58
When there is an ss
or le
1000 or more
500 Pattern 1
120 17 18
obs truc tion on the
Cord
outlet inlet s ide When the obstruction on the outlet side is higher than
23 28
46
hole the unit itself (There is no limit to the height of the
32
27
28
1000 or more
both lateral s ides 500
61
117
H
0~5
L
17 Through hole An obs truc tion
(fl12~fl16)
( Distance between in the overhead s pac e
)
remote controller
100
17
CONTROL BOX and control box ) 50( more
KRC47-1A 150
or
L H or m
ore or
Note) 1. Remote controller cord and Specifications of cord mo
re 500 1000>
staple are not attached. they are 150 ore <
Type
Vinyl cord with sheath or cable 136 or or m
field supplied parts. (Insulated thickness: 1 mm or more)
124 32
mo
re 150
Size 0.75~1.25 mm2 2. For series installation
Total length 500 m 2. For series installation (more than two units) (more than two units)
* Countries requiring EMC: Shield wire
When there are obs truc tions
81
H
25 The dimension of hole.
6
20 ss
1000 or more
or le
500
A
36
a
10
B B
22 25
(30
L H 200 more
13
B
25 20
ore or
77
A A
A
100 rm
0o >
Hole type a (mm) 0o
rm 100 1500
A 6 ore <
41 38
111 24 B 10
41.5
ore
rm
200 )o
or (3 00
mo
re 2 00
19 20
DIME N S ION S (Unit: mm)
30
30
R48NUY1/51NUV1 1345 55 — —
(345~355)
320
350
61
48
(345~355)
350
320
41
30
55
48
96
140 620 140
40
30
96 30 900
140 620 140
30 900 3 4
2
2
1
6 6 1
5 3
5
4 4 7
770
6 7 7
A
5
55
6 6
352
329
5 5
60
223
B
84 55
54 95
54 95
53 95
143
435
55
60
410
89 19 19 80 52
28
89
223
95
95
95
142 145
84
13 67
71 16
7
54
24
89
54
53
16
C 89 19 19 80 52
58
117
D 142 145 13 67
8
70 102
71 16
4 1 Gas pipe connection
16
1 Gas pipe connection
2 Liquid pipe connection
45 376 191 2 Liquid pipe connection
3 Grounding terminal M5(in switch box)
70 102 117
3 Service port (in the unit)
4 Refrigerant piping intake
58
4 Grounding terminal M5 (in switch box)
5 Power supply wiring intake
5 Refrigerant piping intake
6 Control wiring intake
5 6 Power supply wiring intake
7 Drain connection
Note: In some circumstances, with certain machine types, 7 Control wiring intake
it may not be possible to attach the supplied piping. 45 376 191 8 Drain pipe connection
30
30
84
370
396
(345~355)
38
350
320
61
48
35
30
41 146 584 150
30
96
880
140 620 140
30
30 900
4
2 4
3
1 2
3 1
7
7
7 6
6
1170
1345
7 6 5
5
6 5 7
6
5
54
435
5 5
410
60
568
538
60
223
60
84 55
95
157.5
95
148
89
95
95
144
84
24
54
54
89 19 19 80 52
49
name plate 14 67 14 90
49
24
84
142 145 13 67 90 14 115
137
8 71 16
102 11
40
61 11
16
17 18
MEMO
21 40
22