Sei sulla pagina 1di 35

KCL & KCL

Electric Power and Sign Convention


Dispositivos de medición

Generalidades de Ingeniería Eléctrica

Enero-Junio 2017

Universidad de Guanajuato

February 22, 2018

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Ingeniería eléctrica

Electrical engineering is a professional engineering discipline that


generally deals with the study and application of electricity,
electronics, and electromagnetism. This eld rst became an
identiable occupation in the later half of the 19th century after
commercialization of the electric telegraph, and electrical power
supply. It covers a range of subtopics including power, electronics,
control systems, signal processing and telecommunications.

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
¾Qué es la electricidad?

Electricidad: es la acción que producen los electrones al trasladarse


de un punto a otro, ya sea por su falta o exceso de los mismos en
un material

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Origen de la electricidad
Transferencia de electrones

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
¾Como se maniesta la electricidad?

Hay dos formas:


Estática: cuando un cuerpo se carga negativa o positivamente, pero
las cargas no se trasladan.
Como una corriente eléctrica: Cuando los electrones se trasladan.
Este movimiento puede ser en una sola dirección (corriente
continua, CC) o con dirección alternada (corriente alterna, CA).

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Ejercicio 1

An isolated free electron is traveling through an electric eld from


some initial point where its coulombic potential energy per unit
charge (voltage) is 17 kJ/C and velocity = 93 Mm/s to some nal
point where its coulombic potential energy per unit charge is 6
kJ/C. Determine the change in velocity of the electron. Neglect
gravitational forces.

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Ejercicio 2

The capacity of a car battery is usually specied in ampere-hours.


A battery rated at, say, 100 A-h should be able to supply 100 A for
1 h, 50 A for 2 h, 25 A for 4 h, 1 A for 100 h, or any other
combination yielding a product of 100 A-h.

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
a. How many coulombs of charge should we be able to
draw from a fully charged 100 A-h battery?

b. How many electrons does your answer to part a


require?
Enero-Junio 2017 Generalidades de Ingeniería Eléctrica
KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Ejercicio 3

The charge cycle shown in the Figures is an example of a two-rate


charge. The current is held constant at 50 mA for 5 h. Then it is
switched to 20 mA for the next 5 h. Find:

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
a. The total charge transferred to the battery.

b. The energy transferred to the battery.

Hint: Recall that energy w is the integral of power, or


P = dw /dt .

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Ejercicio 4

Batteries do not store electric charge or charge carriers. Charge


carriers (electrons) enter one terminal of the battery, acquire
electrical potential energy, and exit from the other terminal at a
lower voltage. Remember the electron has a negative charge! It is
convenient to think of positive carriers owing in the opposite
direction, that is, conventional current, and exiting at a higher
voltage. All currents in this course, unless otherwise stated, are
conventional current. (Benjamin Franklin caused this mess!) For a
battery with a rated voltage = 12 V and a rated capacity = 350
A-h, determinem
a. The rated chemical energy stored in the battery. ( MJ).
b. The total charge that can be supplied at the rated voltage. (
MC).

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Ejercicio 5

An automotive battery is rated at 120 A-h. This means that under


certain test conditions it can output 1 A at 12 V for 120 h (under
other test conditions, the battery may have other ratings).
a. How much total energy is stored in the battery?
b. If the headlights are left on overnight (8 h), how much energy
will still be stored in the battery in the morning? (Assume a 150-W
total power rating for both headlights together.)

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Ejercicio 6
A car battery kept in storage in the basement needs recharging. If
the voltage and the current provided by the charger during a charge
cycle are shown in the Figure
a. Find the total charge transferred to the battery.
b. Find the total energy transferred to the battery.

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
5.22

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
5.24

Determine la Tension (voltaje) ET =?? y la perdida de potencia de


la resistencia interna para la siguiente conguración. Rint = 0.05Ω

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Tarea

2.9
2.10
2.11
2.12

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
2.13
Use Kirchho's current law to determine the unknown currents in
the circuit of Figure P2.13. Assume that
I0 = −2A, I1 = −4A, IS = 8A, and VS = 12V .

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
2.15

Apply KCL to nd the current I in the circuit of Figure P2.15.

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
2.17

Use Ohm's law and KCL to determine the current I1 in the circuit
of the Figure.

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
2.18.

Find the actual values of the indicated currents and voltages.

Regla de división de voltaje

Rn
Vn = Vs
R1 + R2 + R3 + ...

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Potencia y uso de signos

If positive current ows into the positive terminal of an element,


then the power dissipated is positive (i.e., the element absorbs
power); if the current leaves the positive terminal of an element,
then the power dissipated is negative (i.e., the element delivers
power).

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
2.19
Find the power delivered by each source in the circuits of the Figure

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
2.21

In the circuit of the Figure, determine the power absorbed by the


resistor R and the power delivered by the current source

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Dispositivos de medición

Voltimetro (Voltimeter)
Ohmmetro (Ohmmeter)
Amperimetro (Ammeter)
Wattmetro, Vatimetro (wattmeter)
Termistor

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Termistor

Un termistor es un elemento de detección de temperatura


compuesto por un material semiconductor sinterizado que exhibe
un gran cambio en la resistencia en respuesta a un pequeño cambio
en la temperatura. Los termistores normalmente tienen coecientes
de temperatura negativos lo que signica que la resistencia del
termistor disminuye a medida que la temperatura aumenta.

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Temistor

Benecios de usar un termistor Precisión Los termistores son uno


de los tipos de sensores de temperatura más precisos. Algunos
tienen una precisión de ±0.1 °C o ±0.2 °C dependiendo del modelo
de termistor en particular. Sin embargo, los termistores son
bastante limitados en su rango de temperatura, y trabajan sólo en
un rango nominal de 0 a 100 °C.
Estabilidad Los termistores terminados son químicamente estables y
no resultan afectados signicativamente por el envejecimiento.

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Tipos de termistores

Existen dos tipos de termistores:


NTC (Negative Temperature Coecient)  coeciente de
temperatura negativo
PTC (Positive Temperature Coecient)  coeciente de
temperatura positivo (también llamado posistor).
Cuando la temperatura aumenta, los tipo PTC aumentan su
resistencia y los NTC la disminuyen

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Ejercicio

A thermistor is a nonlinear device which changes its terminal


resistance value as its surrounding temperature changes. The
resistance and temperature generally have a relation in the form
ofRth (T ) = R0 e −β(T −T0 )
where Rth = resistance at temperature T,
R0 = resistance at temperature T0 = 298 K,
β = material constant, K−1 T, T0 = absolute temperature, K
a). If R0 = 300 and β = −0.01K −1 ,
b) If the thermistor is in parallel with a 250 resistor, nd the
expression for the equivalent resistance and plot Rth (T ) on the
same graph for part a) plot Rth(T) as a function of the surrounding
temperature T for 350 ≤ T ≤ 750.

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Ejercicio 2.35
For the circuit shown in Figure P2.35, determine the power
absorbed by the variable resistor R, ranging from 0 to 20 . Plot the
power absorption as a function of R

Plantear una ecuación para la2017


Enero-Junio corriente, en funcion
Generalidades deEléctrica
de Ingeniería R.
KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Sobrecargas

Son corrientes generalmente continuas, producidas por operar


equipos o circuitos a valores mas altos que su capacidad máxima de
corriente
Corto circuito
Es un contacto producido entre dos o más conductores de un
circuito, provocado por una falla del aislamiento que existe entre
ellos. Como su nombre lo indica, la corriente sigue un camino más
corto, es decir, se crea un circuito de mucha menor resistencia, lo
que produce que la corriente se eleve a valores muy altos, debido a
la ley de ohm

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Identicación de los conductores por medio de colores

Para un fácil reconocimiento de los diferentes tipos de conductores


de un circuito, como son los vivos o de fase, el conductor aterrizado
o neutro, y el conductor de tierra, la NOM- 001-SEDE-2005
establece el siguiente código de colores para el aislamiento:
a) Conductor aterrizado o neutro: color blanco o gris claro.
b) Conductor para conexión a tierra de los equipos o conductor de
tierra: verde o verde con franjas amarillas, si está aislado; o puede
ir sin aislamiento (desnudo).
c) Conductores vivos o de fase: cualquier otro color diferente del
blanco, gris claro o verde. Generalmente se emplean el negro y el
rojo para identicarlos

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Componentes de las instalaciones eléctricas

Conductores eléctricos. ˆ Interruptores. ˆ Fusibles. ˆ Centros de


carga. ˆ Contactos y apagadores. ˆ Lámparas. ˆ Canalizaciones y
accesorios

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Conductor eléctrico

Son cuatro los factores que deben ser considerados en la selección


de los conductores: material, exibilidad, forma y dimensiones.
Material : Cobre o aluminio
Dimensiones. El tamaño o sección transversal o calibre de los
conductores eléctricos debe indicarse en mm2 y opcionalmente
entre paréntesis el número de la escala de calibres americanos
(AWG- kcmil), de acuerdo con la Norma Ocial Mexicana de
Conductores Eléctricos NOM-063-SCFI

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
Problemas ocasionados por conductores de mala calidad

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica


KCL & KCL
Electric Power and Sign Convention
Dispositivos de medición
FIN

Estudiar Cap. 2 Libro Fudamentals of electrical engineering, Autor:


Giorgio Rizzoni.
Cap. 5. Libro Analisis de Circuitos. Autor Boylestad.

Enero-Junio 2017 Generalidades de Ingeniería Eléctrica

Potrebbero piacerti anche