Sei sulla pagina 1di 63

CATALOGUE

CONCRETE ANCHORS
AND FIXINGS
Ver.02

Art. No. 0990 081 902


Würth Gulf
is part of The Würth Group. We are the supplier of Fasteners, Automotive Chemicals, Hand Tools & Electrical Supplies also Construction
Assembly Items, Sealants, Power Tools & Safety Solutions.
Established in 2000, Würth Gulf FZE is one of the leading suppliers in the Middle-East. Existing industrial companies and developing
organizations alike can benefit from the uparalleled selection, quality and unbeatable service that is synonymous with the Würth brand.

OUR VISION
Becoming the number 1 in the eyes of
our customers as the best and most
qualified sales team.

OUR MISSION
We love selling.
We inspire our customers.

OUR PRINCIPLES
We request and promote achievements.
The greater the success, the more freedom and liberty.
We are optimistic, dynamic and have powers of self-assertion.
We passionately fight for success.
We consistently pursue everything that has proven to be successful, and we try out
new things.
We strive for perfection in every area of our activities.
We assume responsibility for our actions, work in mutual respect and appreciation
and are straightforward and predictable in everything we do.
The term we consider most important in
dealing with each other is “Thank You”.
- Auto Workshops
- Construction Companies
WE SERVE THE FOLLOWING - Metal and Fabrication
MARKET SECTOR: - Oil and Gas Sector
- Maintenance and Repair Shops
- Industrial Companies
- And all other Manufacturing Sectors.

OUR PRODUCT RANGE :


More Than 100, 000 Products
We have all sizes and dimensions that are suited to the needs of our customers in industry and trade. Würth offers you as our client
a comprehensive product package – all in one solution.

•Service and Systems •Orsy® Assortments and Workshop Equipment


•Chemical Technical Products •Personal Protective Equipment (PPE)
•Fasteners / Fittings •Construction Accessories
•Concrete Anchors and Fixings •Electrical
•Fire Protection Systems •Sanitary
•Material Processing •Automotive / Cargo Accessories and Spare Parts
•General Tools/Equipment •Lubricants and Degreasers
•master ® Power Tools •Hand and Power Tools
•Workshop / Garage Equipment •Sealants and Adhesives

Over 3 million customers


Worldwide, there are over 400 Wurth companies in more than 80 countries and has 65,000 employees on its payroll. This guarantee our
customers can rely on our high quality, excellent service and innovative products.

To each customer Würth allocates our Sales Consultant, who is strongly focused on the individual needs of the client. We have adopted this at-
titude to benefit you, the customer. Our daily commitment helps us to find new approaches so that we always improve. We aim to supply every
customer with every article at any time in any place. We therefore have developed modular systems and logistics tailored to the individual needs
of the customers. In October 2009, we won the German Logistics Award for this concept.

Our philosophy
We owe it to Reinhold Würth that the Würth Group has a clear business orientation: It is marked by a strong brand policy, future-oriented product
strategy, closeness to the customer, clear quality offensive, thinking in terms of visions and not least by a strong corporate culture. Bettina Würth,
Reinhold Würth’s daughter and Chairwoman of the Advisory Board together with the members of the Central Managing Board see to it that these
values are filled with life and developed further.
CONTENT
Mechanical Heavy Duty Anchors
Fixanchor W-FAZ/S 06 - 07
Fixanchor W-FAZ/A4, W-FAZ/HCR 08 - 09
Fixanchor W-FAZ-IG/S 10 - 12
Fixanchor W-FAZ-IG/A4, W-FAZ-IG/HCR 13 - 15
High Performance Anchor W-HAZ/S 16 - 19
High Performance Anchor W-HAZ/A4 20 - 21
High Performance Anchor W-VIZ/S and WIT-VM 100 22 - 25
High Performance Anchor W-VIZ/A4 and WIT-VM 100 26 - 30
Hollow Ceiling Anchor W-HD 31 - 32
Fixanchor W-FA/S, W-FA/F 33 - 35
Fixanchor W-FA/A4, W-FA/HCR 36 - 37
Drop-in Anchor W-ED/S 38 - 39
Drop-in Anchor W-ED/A4 40 - 41

Chemical Anchors
Bonded Anchor/ Capsule system W-VP 42 - 43
Injection System WIT-PE 500 44 - 46
Injection System WIT-VM 250 47 - 50
Cleaning Accessories 50
Threaded rods 51

Light Duty Fixings

Frame fixing W-FRA 10 52 - 54


Frame fixing W-UR 8 55 - 56
Frame fixing W-UR 10 57 - 58
Zebra Shark W-ZX 59
Aircrete Anchor W-GB 60
Gypsum plasterboard Anchor W-GS 61
W-FAZ/S
FIXANCHOR W-FAZ/S Approved for:
Concrete C20/25 to C50/60

Benefits:
• All the many approvals guarantee its
reliable function for all applications even in
cracked and non-cracked concrete.
• The optimized unit of cone bolt and expansion
sleeve avoids concrete spalling at smallest edge
distances too.
• The length identifier on the front end of the bolt
Machine Setting Tool facilitates the inspection of correct installation.
Art. No. 0904 908 016 • The multitude of types offers the most economic
anchor for all applications in any case. In
particular the one with the big washer is mainly
used in timber construction.
Applications:

Approvals and Certificates

Technical Data:
Head configuration Externally threaded
Environmental conditions Indoor, dry conditions
Material composition Steel, galvanized
Type of fastening Through-fastening
Metal structures, metal profiles, brackets, foot plates, supports, cable
Suitable for Cracked concrete
conduits, piping, railings, wooden structures, beams. Non-cracked concrete

Thread size M8 M10 M12 M16 M20 M24 M27

Effective anchorage depth hef [mm] 46 60 70 85 100 115 125


Non-cracked concrete
Tensile C20/25 Nrec [kN] 5.7 7.6 11.9 16.7 24.0 29.7 33.6
C50/60 Nrec [kN] 7.5 11.8 18.5 25.8 37.3 46.0 52.1
Shear ≥ C20/25 Vrec [kN] 8.6 12.6 17.1 34.3 37.1 59.3 67.2
Cracked concrete
Tensile C20/25 Nrec [kN] 2.4 4.3 7.6 11.9 17.2 21.2 24.0
C50/60 Nrec [kN] 3.7 6.6 11.8 18.5 26.6 32.8 37.2
Shear ≥ C20/25 Vrec [kN] 8.6 12.6 17.1 26.9 34.4 42.4 48.0
1)
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.
Installation:

06
W-FAZ/S
W-FAZ/S
h1
hef tfix

FIXANCHOR W-FAZ/S

FIXANCHOR W-FAZ /S Tinst

hmin

Standard anchorage depth Reduced anchorage depth


M x Anchor Seismic
perfor-
Max. fixture Drill Ø x drill Eff. anchorage Max. fixture Drill Ø x drill hole Eff. anchorage Thread Wrench
length thickness depth
mance
thickness depth Art. No.
hole depth category depth length size SW
(mm)
tfix/mm h1/mm hef/mm C1 C2 tfix,red/mm h1,red/mm hef,red/mm mm mm
M8 x 65 — — — — — 11 22 5928 258 011
M8 x 75 10 — — 21 32 5928 208 010
M8 x 80 15 — — 26 37 5928 208 015
8 x 49 35 13
M8 x 95 30 8 x 60 46 — — 41 52 5928 208 030
M8 x 115 50 — — 61 72 5928 208 050
M8 x 165 100 — — 111 122 5928 208 100
M10 x 70 — — — — — 10 22 5928 251 010
M10 x 80 — — — — — 20 32 5928 251 020
M10 x 90 10 ✓ ✓ 30 42 5928 210 010
M10 x 95 15 ✓ ✓ 35 47 5928 210 015
M10 x 100 20 ✓ ✓ 40 10 x 55 40 52 5928 210 020
17
M10 x 110 30 ✓ ✓ 50 62 5928 210 030
10 x 75 60
M10 x 130 50 ✓ ✓ 70 82 5928 210 050
M10 x 155 75 ✓ ✓ 95 107 5928 210 075
M10 x 180 100 ✓ ✓ 120 132 5928 210 100
M10 x 230 150 — — — — 80 0904 521 005
M12 x 85 — — — — — 10 26 5928 252 010
M12 x 95 — — — — — 20 36 5928 252 020
M12 x 110 15 ✓ ✓ 35 51 5928 212 015
M12 x 115 20 ✓ ✓ 40 56 5928 212 020
M12 x 125 30 ✓ ✓ 50 12 x 70 50 66 5928 212 030
M12 x 145 50 ✓ ✓ 70 86 5928 212 050
19
M12 x 160 65 ✓ ✓ 85 101 5928 212 065
12 x 90 70
M12 x 180 85 ✓ ✓ 105 121 5928 212 085
M12 x 200 105 ✓ ✓ 125 141 5928 212 105
M12 x 220 125 — — 80 0904 521 217
M12 x 240 145 — — — — 80 0904 521 218
M12 x 255 160 — — 80 0904 521 219
M16 x 115 — — — — — 15 36 5928 256 015
M16 x 125 5 ✓ ✓ 25 46 5928 216 005
M16 x 135 15 ✓ ✓ 35 56 5928 216 015
16 x 90 65
M16 x 145 25 ✓ ✓ 45 66 5928 216 025
M16 x 170 50 ✓ ✓ 70 91 24 5928 216 050
16 x 110 85
M16 x 200 80 ✓ ✓ 100 121 5928 216 080
M16 x 220 100 — — — 80 0904 521 603
M16 x 260 140 — — — — — 80 0904 521 604
M16 x 300 180 — — — 80 0904 521 605
M20 x 165 30 ✓ ✓ — 50 5928 220 030
M20 x 195 60 ✓ ✓ — 70 5928 220 060
20 x 125 100 — — 30
M20 x 265 130 — — — 80 0904 522 003
M20 x 285 150 — — — 80 0904 522 004
M24 x 190 30 — — — 55 0904 522 401
M24 x 220 60 — — — 85 0904 522 402
24 x 145 115 — — 36
M24 x 235 75 — — — 100 0904 522 403
M24 x 260 100 — — — 125 0904 522 404
M27 x 210 30 — — — 62 0904 522 701
M27 x 240 60 27 x 160 125 — — — — — 92 41 0904 522 702
M27 x 280 100 — — — 132 0904 522 703
07
W-FAZ/A4
FIXANCHOR W-FAZ/A4, W-FAZ/HCR Approved for:
Concrete C20/25 to C50/60

Benefits:
• All the many approvals guarantee its
reliable function for all applications even in cracked
and non-cracked concrete.
• The optimized unit of cone bolt and expansion sleeve
avoids concrete spalling at smallest edge distances
too.
• The length identifier on the front end of the bolt
Machine Setting Tool facilitates the inspection of correct installation.
Art. No. 0904 908 016
• The multitude of types offers the most economic
anchor for all applications in any case. In particular
the one with the big washer is mainly used in timber
construction.

Applications:

Approvals and Certificates

Technical Data:
Head configuration Externally threaded
Environmental conditions
Indoor, outdoor

Material composition A4 stainless steel / HCR Highly
corrosion-resistant steel
Type of fastening Through-fastening
Cracked
Suitable for concrete
Metal structures, metal profiles, brackets, foot plates, supports, Non-cracked concrete
cable conduits, piping, railings, wooden structures, beams.

Thread size M8 M10 M12 M16 M20 M24 M24


Effective anchorage depth hef [mm] 46 60 70 85 100 100 125
Non-cracked concrete
Tensile C20/25 Nrec [kN] 5.7 7.6 11.9 16.7 24.0 24.0 33.6
C50/60 Nrec [kN] 7.6 11.8 18.5 25.8 37.3 37.3 52.1
Shear ≥ C20/25 Vrec [kN] 7.4 11.4 17.1 31.4 43.9 48.1 67.2
Cracked concrete
Tensile C20/25 Nrec [kN] 2.4 4.3 7.6 11.9 17.2 17.2 19.0
C50/60 Nrec [kN] 3.7 6.6 11.8 18.5 26.6 26.6 29.5
Shear ≥ C20/25 Vrec [kN] 7.4 11.4 17.1 26.9 34.4 34.4 48.0
1)
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.
Installation:

08
W-FAZ/A4
W-FAZ/A4
FIXANCHOR W-FAZ/A4 h1
hef tfix

FIXANCHOR W-FAZ /A4


Tinst

hmin

Standard anchorage depth Reduced anchorage depth


M x Anchor Seismic
perfor-
Max. fixture Drill Ø x drill Eff. anchorage Max. fixture Drill Ø x drill hole Eff. anchorage Thread Wrench
length thickness depth
mance
thickness depth Art. No.
hole depth category depth length size SW
(mm)
tfix/mm h1/mm hef/mm C1 C2 tfix,red/mm h1,red/mm hef,red/mm mm mm
M8 x 65 — — — — — 11 22 5928 458 011
M8 x 75 10 — — 21 32 5928 458 010
M8 x 80 15 — — 26 37 5928 458 015
8 x 49 35 13
M8 x 95 30 8 x 60 46 — — 41 52 5928 458 030
M8 x 115 50 — — 61 72 5928 458 050
M8 x 165 100 — — 111 122 5928 458 100
M10 x 70 — — — — — 10 22 5928 451 010
M10 x 80 — — — — — 20 32 5928 451 020
M10 x 90 10 ✓ ✓ 30 42 5928 410 010
M10 x 95 15 ✓ ✓ 35 47 5928 410 015
10 x 55 40 17
M10 x 110 30 ✓ ✓ 50 62 5928 410 030
10 x 75 60
M10 x 130 50 ✓ ✓ 70 82 5928 410 050
M10 x 155 75 ✓ ✓ 95 107 5928 410 075
M10 x 180 100 ✓ ✓ 120 132 5928 410 100
M12 x 85 — — — — — 10 26 5928 452 010
M12 x 95 — — — — — 20 36 5928 452 020
M12 x 110 15 ✓ ✓ 35 51 5928 412 015
M12 x 115 20 ✓ ✓ 40 56 5928 412 020
12 x 70 50
M12 x 125 30 ✓ ✓ 50 66 5928 412 030
M12 x 145 50 ✓ ✓ 70 86 5928 412 050
M12 x 160 65 ✓ ✓ 85 101 5928 412 065
M12 x 180 85 ✓ ✓ 105 121 19 5928 412 085
M12 x 200 105 12 x 90 70 ✓ ✓ 125 141 5928 412 105
M12 x 220 125 — — — 80 0904 621 206
M12 x 255 160 — — — 80 0904 621 207
M12 x 275 180 — — — — — 80 0904 621 208
M12 x 285 190 — — — 80 0904 621 209
M12 x 300 205 — — — 80 0904 621 210
M12 x 325 230 — — — 80 0904 621 211
M16 x 115 — — — — — 15 36 5928 456 015
M16 x 125 5 ✓ ✓ 25 46 5928 416 005
M16 x 135 15 ✓ ✓ 35 56 5928 416 015
16 x 90 65
M16 x 145 25 ✓ ✓ 45 66 5928 416 025
M16 x 170 50 ✓ ✓ 70 91 5928 416 050
M16 x 200 80 ✓ ✓ 100 121 24 5928 416 080
16 x 110 85
M16 x 220 100 — — — 80 0904 616 100
M16 x 280 160 — — — 80 0904 616 160
M16 x 300 180 — — — — — 80 0904 616 180
M16 x 325 205 — — — 80 0904 616 205
M16 x 340 220 — — — 80 0904 616 220
M20 x 165 30 ✓ ✓ — 50 5928 420 030
M20 x 195 60 ✓ ✓ — 70 5928 420 060
20 x 125 100 — 30
M20 x 265 130 — — — 80 0904 620 130
M20 x 285 150 — — — 80 0904 620 150
M24 x 200 30 — — — 58 0904 624 030
M24 x 230 60 24 x 155 125 — — — — — 88 36 0904 624 060
M24 x 245 75 — — — 103 0904 624 075
09
W-FAZ-IG/S
FIXANCHOR W-FAZ-IG/S
Pre fastening Approved for:
g Cotter-pin installation
Through fastening
Through-bolt mounting Concrete C20/25 to C50/60

Benefits:
+ + • All screws/bolts available in the product line can be
Ty p e S Type SK Ty p e B Ty p e S Ty p e S K Ty p e B used for both pre fastening and through fastening.
• Immediately loadable – no waiting time.
Cotter-pin installation Through-bolt mounting • Also suitable for temporary fastening
(pre fastening, e.g. stadium seats for flexible use flush
+ + with surface without danger of injury).
+ +
Ty p e S Type SK Ty p e B Ty p e S Ty p e S K Ty p e B

Machine Setting Tool


+ +

Approvals and Certificates:

Important information!
Please only set the W-FAZ-IG fixing anchor together with the
l
related, approval-conformant setting tools (anchor system).
Applications: l Hexagon bolts, countersunk head screws, washers, countersunk
head washers and nuts are specially coated and only permissible Technical Data:
st Reports Important information!
in anchor system in accordance with ETA-02/0017. Therefore,
l Pleaseplease
only setorder separately
the W-FAZ-IG fixingatanchor
the same timewith the 1) (see product
together Head configuration Inner thread
Fire information,
related Page 3).setting tools (anchor system).
approval-conformant Environmental conditions Indoor, dry conditions
l Hexagon
l Commonbolts, countersunk head screws, 2) washers, countersunk
esistance threaded rods may only be used if the conditions Material composition Steel, galvanized
head washers and nuts are specially coated and only permissible
specified
systeminin the approval withETA-02/0017 (Appendix5, Table 3)
ect flame effect in anchor accordance ETA-02/0017. Therefore, Pre
Type of fastening fastening /
F30 – F120 please(material quality,atdimensions,
order separately the same timemechanical properties
1) (see product according
TK-DIN 4102-2: to EN10204:2004)
information, Page 3). are met. Through-fastening
1977-09)
l The threaded
l Common torque necessary
rods ) for
mayanchoring can
only be used beconditions
if the applied with Würth for Cracked concrete
2
specified in thewrenches
approval ETA-02/0017
Suitable
torque and suitable(Appendix
attachments 5, Table 3)
(insertion open-end Non-cracked concrete
(material quality, dimensions, mechanical properties according
wrench).
to EN 10204:2004) are met.
The torque necessary for anchoring can be applied with Würth
l
Metal structures, metal
torque profiles,
wrenches and suitable attachments (insertion open-end
l Immediately
brackets, foot plates,
wrench). supports,loadable – no waiting time
l Fixing anchor cone with patented plastic coating enables reliable expansion later
ackets, footcable
plates,conduits, piping,
2. Advantages
l Elegant appearance thanks to countersunk head screws for visible fastening with Range of loading: C20/25
eams, stadium
railings, wooden simultaneous
l High loads, highand
small axle bases load-bearing capacity (e.g. railings)
edge clearances
ot plates, supports, l All lscrews/bolts available in the product line (see product information, Page 3) can be used
Also suitable for temporary Size M6 M8 M10 M12
s, reinforced
ned etc. or non- for both cotter-pin and through-bolt mountingfastening (cotter-pin mounting, e.g. stadium seats for
or non-reinforced l Can be flexible use – flush
loaded immediately with
– no waitsurface
time without danger of injury) hef [mm] 45 58 65 80
0/25
50/60 and at most
in accordance l Fixed
l anchor
Reliable coneinstallation
with patented due
plastictocoating facilitates of
application reliable later expansion
prescribed torque
l Elegant appearance thanks to countersunk head screws for visible fastening with Non-cracked concrete
(concrete tensile zone) simultaneous high load-bearing capacity (e.g. railings)
ncrete
re app
out
(concrete
zone)roval)
l 3. Properties
Also suitable for temporary fastening (cotter-pin mounting, e.g. stadium seats for flexible
use – flush with surface without danger of injury)
Nrec [kN] 4.8 6.3 7.9 11.9
Vrec1) [kN] 3.3 3.9 5.9 14.7
own
one weight, l l Force-controlled/torque-controlled
Reliable spreading anchor of electrogalvanized steel
installation due to application of prescribed torque
gs) in the sizes M6, M8, M10 and M12 Vrec2) [kN] 2.9 4.3 6.2 13.9
tdoors
ads
(including
specially aggressive con- 3. Properties
l Galvanized steel M6 – M12: ETA-02/0017 for individual fastening Cracked concrete
cderloads l (Option 1, uncracked spreading
Force-controlled/torque-controlled and crackedanchor concrete)
of A4 stainless steel in the sizes M6,
Nrec [kN] 2.0 3.6 4.8 7.9
especially M8,l M10 and M12
lternating immersion in Dimensioned in accordance with the “European Technical App roval Guideline
Stainless steel A4 and HCR highly corrosion resistant steel, M6 – M12:
ooms
orine in indoor pools
l
(ETAG)forfor
ETA-02/0017 Metalfastening
individual Anchors for 1,Anchoring
(Option uncracked and in cracked
Concrete”,
concrete)Part 2 (ETAG 001-2) Vrec1) [kN] 3.3 3.9 5.9 14.7
l l Fire resistance
Dimensioned in accordance (anchoring base:Technical
with the “European concrete App C20/25 to C50/60):
roval Guideline (ETAG) for R30, R60, R90, Vrec2) [kN] 2.9 4.3 6.2 13.9
Metal Anchors for Anchoring in Concrete”, Part 2 (ETAG 001-2)
R120:(anchoring
Fire resistance Technical Report
base: concreteTRC20/25
020 “Assessment
to C50/60): of anchoring in concrete with regard 1) 2)
l
to the
R30, R60, R90,fire resistance”
R120: (included
Technical Report TR 020in“Assessment
ETA-02/0017)
of anchoring in concrete for pre fastening for through fastening
Installation:
rmation, Page 3)
with regard to the fire resistance” (included in ETA-02/0017)
F30, F60, F90, F120 (W-FAZ-IG/A4): Fire stress pursuant to DIN 4201-2:1977-09
(ETK – Einheitstemperaturkurve (uniform temperature curve))
Flush Installation Through Installation

Through-bolt mounting
Through-bolt mounting

10
Apply torque Drill hole Clean drilled
hole
Knock in anchor
with setting tool
Apply torque

Apply torque Drill hole Clean Knock in anchor Apply torque


W-FAZ-IG/S

Article description Art. No. Drill dia. Min. drill hole Anchor Fixture Fixture Thread PU
depth length thickness thickness size
Typ S Typ SK

Pre
fastening do h 2 l tfix tfix ØxlG
mm mm mm mm mm mm Qty.
W-FAZ-IG/S M6-12-14/50 0904 706 110 8 60 50 12 14 M6 x 20 100
W-FAZ-IG/S M8-8-15/62 0904 708 110 10 75 62 8 15 M8 x 22 50
W-FAZ-IG/S M10-11-19/70 0904 710 110 12 90 70 19 11 M10 x 23 25
W-FAZ-IG/S M12-14-21/86 0904 712 110 16 105 86 21 14 M12 x 27 20
Through fastening

W-FAZ-IG/S M6-10-14/60 0904 706 011 8 60 60 10 14 M6 x 20 100


W-FAZ-IG/S M6-20-24/70 0904 706 012 8 60 70 20 24 M6 x 20 100
W-FAZ-IG/S M6-30-34/80 0904 706 013 8 60 80 30 34 M6 x 20 100
W-FAZ-IG/S M8-10-15/72 0904 708 011 10 75 72 10 15 M8 x 22 50
W-FAZ-IG/S M8-20-25/82 0904 708 012 10 75 82 20 25 M8 x 22 50
W-FAZ-IG/S M8-30-35/92 0904 708 013 10 75 92 30 35 M8 x 22 50
W-FAZ-IG/S M10-10-16/80 0904 710 011 12 90 80 10 16 M10 x 23 25
W-FAZ-IG/S M10-20-26/90 0904 710 012 12 90 90 20 26 M10 x 23 25
W-FAZ-IG/S M10-30-36/100 0904 710 013 12 90 100 30 36 M10 x 23 25
W-FAZ-IG/S M12-10-17/96 0904 712 011 16 105 96 10 17 M12 x 27 20
W-FAZ-IG/S M12-20-27/106 0904 712 012 16 105 106 20 27 M12 x 27 20
W-FAZ-IG/S M12-30-37/116 0904 712 013 16 105 116 30 37 M12 x 27 20


Screw hexagon head DIN 933

Steel grade Fixture Thread Wrench PU


Article description Art. No.
thickness size size

Pre fastening

tfix ØxlG SW

mm mm Qty.

Typ S M6 x 25 0904 706 120 8.8 4-12 M6 x 25 10 100


Typ S M8 x25 0904 708 120 8.8 2-8 M8 x 25 13 50
Typ S M10 x 40 0904 710 120 8.8 15-19 M10 x 40 17 25
Typ S M12 x 45 0904 712 120 8.8 16-21 M12 x 45 19 20
Through fastening

Typ S M6 x 16 0904 706 020 8.8 10/20/30 M6 x 16 10 100


Typ S M8 x 18 0904 708 020 8.8 10/20/30 M8 x 18 13 50
Typ S M10 x 20 0904 710 020 8.8 10/20/30 M10 x 20 17 25
Typ S M12 x 25 0904 712 020 8.8 10/20/30 M12 x 25 19 20

11
W-FAZ-IG/S

Countersunk Screw DIN7991

Article description Art. No. Steel grade Fixture Thread Wrench PU


fixness size size

Pre - fastening
tfix ØxlG SW
mm mm Qty.
Typ SK M6 x 25 0904 706 130 8.8 6-14 M6 x 25 Tx 30 100
Typ SK M8 x 30 0904 708 130 8.8 9-15 M8 x 30 Tx 40 50
Typ SK M10 x 30 0904 710 130 8.8 8-11 M10 x 30 Innen 6-kt. 6mm 25
Typ SK M12 x 35 0904 712 130 8.8 9-14 M12 x 35 Innen 6-kt. 8mm 20

Through fastening

Typ SK M6 x 16 0904 706 030 8.8 14/24/34 M6 x 16 Tx30 100


Typ SK M8 x 20 0904 708 030 8.8 15/25/35 M8 x 20 Tx 40 50
Typ SK M10 x 25 0904 710 030 8.8 16/26/36 M10 x 25 Innen6-kt. 6mm 25
Typ SK M12 x 30 0904 712 030 8.8 17/27/37 M12 x 30 Innen6-kt. 8mm 20

Cotter-pin installation Through-bolt mounting


R

Setting Tool + +
read
on
Ty p e S
Through-bolt
Type SK Ty p e B Ty p e S Ty p e S K Ty p e B
esistant steel – Anchor diameter mounting M6 M8 M10 M12

++ +
Ty p e B
Pre fastening
Ty p e S Ty p e S K Ty p e B
0904 706 150 0904 708 150 0904 710 150 0904 712 150
washer 1)

ETA-02/0017)
Through fastening
+
rete surface)
0904 706 050 0904 708 050 0904 710 050 0904 712 050

Test Reports Important information!


Please only set the W-FAZ-IG fixing anchor together with the
l

Fire related approval-conformant setting tools (anchor system).


l Hexagon bolts, countersunk head screws, washers, countersunk
Resistance head washers and nuts are specially coated and only permissible
Direct flame effect in anchor system in accordance with ETA-02/0017. Therefore,
F30 – F120 please order separately at the same time 1) (see product
nt information!(ETK-DIN 4102-2: information, Page 3).
) set the W-FAZ-IG
nly 1977-09) Common
fixing anchor together lwith the threaded rods 2) may only be used if the conditions

approval-conformant setting tools (anchor system). specified in the approval ETA-02/0017 (Appendix 5, Table 3)
n bolts, countersunk head screws, washers, countersunk(material quality, dimensions, mechanical properties according
ashers and nuts are specially coated and only to EN 10204:2004) are met.
permissible
r system in accordance with ETA-02/0017. Therefore,l The torque necessary for anchoring can be applied with Würth
rder separately at the same time torque
1) (see wrenches and suitable attachments (insertion open-end
product
on, Page 3). wrench).
n threaded rods 2 ) may only be used if the conditions
d in the approval ETA-02/0017 (Appendix 5, Table 3) 2. Advantages
l quality, dimensions, mechanical properties according
l High loads, small axle bases and edge clearances
es, brackets, foot
0204:2004) areplates,
met. supports, l All screws/bolts available in the product line (see product information, Page 3) can be used
ms, stadium seats, etc.
ue necessary for anchoring can be applied for both cotter-pin and through-bolt mounting
with Würth
used in reinforced or non-reinforced l Can be loaded immediately – no wait time
wrenches andC50/60
5 and at most suitableinattachments
accordance (insertion open-end
l Fixed anchor cone with patented plastic coating facilitates reliable later expansion
l Elegant appearance thanks to countersunk head screws for visible fastening with
ed concrete (concrete tensile zone) simultaneous high load-bearing capacity (e.g. railings)
antages
e)
ural stone (without app roval)
l Also suitable for temporary fastening (cotter-pin mounting, e.g. stadium seats for flexible
use – flush with surface without danger of injury)
small axle (e.g.
atic loads basesown andweight,
edge clearances l Reliable installation due to application of prescribed torque
.olts available
façades, in the product line (see product information, Page 3) can be used
railings)
ndoor rooms, outdoors mounting
er-pin and through-bolt
ded
ooms immediately
12
– no wait time
(including
if no especially aggressive con- 3. Properties
r cone with patented plastic coating facilitates reliable later expansion
earance l Force-controlled/torque-controlled spreading anchor of A4 stainless steel in the sizes M6,
an be usedthanks to countersunk
under especially head screws for visible fastening with
M8, M10 and M12
sg.high load-bearing
continuous, capacity
alternating (e.g. railings)
immersion in
ee for temporary fastening (cotter-pin mounting, l Stainless
e.g. stadium steel A4
seats for and HCR highly corrosion resistant steel, M6 – M12:
flexible
containing chlorine in indoor pools ETA-02/0017 for individual fastening (Option 1, uncracked and cracked concrete)
with surface without danger of injury)
W-FAZ-IG/A4, W-FAZ-IG/HCR
FIXANCHOR W-FAZ-IG/A4, W-FAZ-IG/HCR Approved for:
Concrete C20/25 to C50/60
Cotter-pin installation Through-bolt mounting
Benefits:
• All screws/bolts available in the product line
+ + can be used for both pre fastening and through
Ty p e S Type SK Ty p e B Ty p e S Ty p e S K Ty p e B fastening

• Immediately loadable – no waiting time.
• Also suitable for temporary fastening
Cotter-pin installation Through-bolt mounting (pre fastening, e.g. stadium seats for flexible
+ +
use- flush with surface without danger of injury)

+ +
7)
Ty p e S Type SK Ty p e B Ty p e S Ty p e S K Ty p e B

Machine Setting
+ Tool +
Approvals and Certificates:

Test Reports Important information!


l Please only set the W-FAZ-IG fixing anchor together with the
Fire related approval-conformant setting tools (anchor system).
l Hexagon bolts, countersunk head screws, washers, countersunk
Resistance head washers and nuts are specially coated and only permissible
Direct flame effect in anchor system in accordance with ETA-02/0017. Therefore,
F30 – F120 please order separately at the same time 1) (see product
(ETK-DIN 4102-2: information, Page 3).
1977-09) Applications: l Common threaded rods 2 ) may only be used if the conditions
specified in the approval ETA-02/0017 (Appendix 5, Table 3)
(material quality, dimensions, mechanical properties according Technical Data:
st Reports Important information!
to EN 10204:2004) are met.
l The torque
l Please only setnecessary
the W-FAZ-IG for anchoring
fixing anchorcan be applied
together with
with theWürth Head configuration Inner thread
torque
related wrenches and suitable
approval-conformant attachments
setting tools (anchor(insertion open-end
system). Environmental conditions
Indoor, Outdoor
Fire wrench).
l Hexagon bolts, countersunk head screws, washers, countersunk
esistance head washers and nuts are specially coated and only permissible A4 stainless steel / HCR highly
ect flame effect 2. Advantages
in anchor system in accordance with ETA-02/0017. Therefore, Material composition corrosion-resistant steel
F30 – F120 l please order
High loads, separately
small axle basesatandtheedge
sameclearances
time 1) (see product
TK-DIN 4102-2:
foot plates, supports, All screws/bolts
l information, Pageavailable
3). in the product line (see product information, Page 3) can be used Type of fastening Pre fastening / Through fastening
eats, etc.
1977-09) for both cotter-pin and through-bolt mounting
orced or non-reinforced
l Common threaded rods 2
l Can be loaded immediately – no wait time
) may only be used if the conditions Cracked concrete
t C50/60 in accordance l specified
Fixed anchorin the
coneapproval ETA-02/0017
with patented (Appendix
plastic coating facilitates5, Tablelater
reliable 3) expansion Suitable for
Non-cracked concrete
l (material quality, dimensions,
Elegant appearance mechanical
thanks to countersunk headproperties according
screws for visible fastening with
(concrete tensile zone) to EN 10204:2004)
simultaneous are met.capacity (e.g. railings)
high load-bearing
Alsotorque
l l The suitablenecessary
for temporary forfastening
anchoring (cotter-pin
can bemounting,
appliede.g.withstadium
Würthseats for flexible
without app roval) use – flush with surface
torque wrenches and suitable without danger of injury)(insertion open-end
attachments
.g. own weight, l Reliable installation due to application of prescribed torque
ilings) wrench).

2.3.Advantages
Properties
outdoors (including
o especially aggressive con- Range of loading: C20/25
l l Force-controlled/torque-controlled
High loads, small axle bases and edgespreading clearances anchor of A4 stainless steel in the sizes M6,
otunder especially
plates, supports, l All M8, M10 andavailable
screws/bolts M12 in the product line (see product information, Page 3) can be used Size M6 M8 M10 M12
s,s, alternating
etc. immersion in l Stainless
for steel A4
both cotter-pin andand HCR highly
through-bolt corrosion resistant steel, M6 – M12:
mounting
chlorine in indoor pools
ed or non-reinforced l CanETA-02/0017 for individual
be loaded immediately fastening
– no (Option 1, uncracked and cracked concrete)
wait time hef [mm] 45 58 65 80
50/60 in accordance l l Dimensioned
Fixed anchor cone in accordance
with patentedwith the “European
plastic Technical
coating facilitates App later
reliable roval Guideline (ETAG) for
expansion
l Metalappearance
Elegant Anchors forthanks
Anchoring in Concrete”,
to countersunk head Partscrews
2 (ETAG 001-2)fastening with
for visible Non-cracked concrete
(concrete tensile zone) l Fire resistance
simultaneous high(anchoring
load-bearing base: concrete
capacity (e.g.C20/25
railings)to C50/60):
l AlsoR30, R60,for
suitable R90, R120: fastening
temporary Technical(cotter-pin
Report TRmounting,
020 “Assessment of anchoring
e.g. stadium seats for in concrete
flexible Nrec [kN] 4.8 6.3 7.9 11.9
out app roval) usewith regard
– flush
F30, F60,
withtosurface
the firewithout
F90, F120
resistance” (included
danger in ETA-02/0017)
of injury) Vrec1) [kN] 3.3 5.3 6.1 13.5
own weight, l Reliable installation due to (W-FAZ-IG/A4): Fire stresstorque
application of prescribed pursuant to DIN 4201-2:1977-09
gs) (ETK – Einheitstemperaturkurve (uniform temperature curve)) Vrec2) [kN] 4.2 4.3 5.5 16.9
tdoors (including
specially aggressive con- 3. Properties Cracked concrete
l Force-controlled/torque-controlled spreading anchor of A4 stainless steel in the sizes M6,
der especiallyMetal structures, metaland profiles,
M8,Through-bolt
M10 M12 mounting brackets, foot plates, supports, Nrec [kN] 2.0 3.6 4.8 7.9
lternating immersion in l Stainless steel A4 and HCR highly corrosion resistant steel, M6 – M12:
orine in indoorcable
pools conduits, piping,forrailings,
ETA-02/0017 wooden
individual fastening structures,
(Option 1, uncrackedbeams, stadium,
and cracked concrete)
Vrec1) [kN] 3.3 5.3 6.1 13.5
seats.
l Dimensioned in accordance with the “European Technical App roval Guideline (ETAG) for
Metal Anchors for Anchoring in Concrete”, Part 2 (ETAG 001-2)
Vrec2) [kN] 4.2 4.3 5.5 16.9
l Fire resistance (anchoring base: concrete C20/25 to C50/60): 1) 2)
R30, R60, R90, R120: Technical Report TR 020 “Assessment of anchoring in concrete for pre fastening for through fastening
Installation: with regard to the fire resistance” (included in ETA-02/0017)
F30, F60, F90, F120 (W-FAZ-IG/A4): Fire stress pursuant to DIN 4201-2:1977-09
(ETK – Einheitstemperaturkurve (uniform temperature curve))
Flush Installation Through Installation
hor Apply torque Drill hole Clean drilled Knock in anchor Apply torque
ool Through-bolt mounting
hole with setting tool

Apply torque Drill hole Clean drilled Knock in anchor Apply torque 13
hole with setting tool
W-FAZ-IG/A4, W-FAZ-IG/HCR


Article description Art. No. Drill dia. Min. drill hole Anchor Fixture Fixture Thread
depth length thickness thickness size PU
Typ S Typ SK

Pre
fastening do h 2 l tfix tfix ØxlG
mm mm mm mm mm mm Qty.
W-FAZ-IG/A4 M6-12-14/50 0904 806 110 8 60 50 12 14 M6 x 20 100
W-FAZ-IG/A4 M8-8-15/62 0904 808 110 10 75 62 8 15 M8 x 22 50
W-FAZ-IG/A4 M10-11-19/70 0904 810 110 12 90 70 19 11 M10 x 23 25
W-FAZ-IG/A4 M12-14-21/86 0904 812 110 16 105 86 21 14 M12 x 27 20
Through fastening

W-FAZ-IG/A4 M6-10-14/60 0904 806 011 8 60 60 10 14 M6 x 20 100


W-FAZ-IG/A4 M6-20-24/70 0904 806 012 8 60 70 20 24 M6 x 20 100
W-FAZ-IG/A4 M6-30-34/80 0904 806 013 8 60 80 30 34 M6 x 20 100
W-FAZ-IG/A4 M8-10-15/72 0904 808 011 10 75 72 10 15 M8 x 22 50
W-FAZ-IG/A4 M8-20-25/82 0904 808 012 10 75 82 20 25 M8 x 22 50
W-FAZ-IG/A4 M8-30-35/92 0904 808 013 10 75 92 30 35 M8 x 22 50
W-FAZ-IG/A4 M10-10-16/80 0904 810 011 12 90 80 10 16 M10 x 23 25
W-FAZ-IG/A4 M10-20-26/90 0904 810 012 12 90 90 20 26 M10 x 23 25
W-FAZ-IG/A4 M10-30-36/100 0904 810 013 12 90 100 30 36 M10 x 23 25
W-FAZ-IG/A4 M12-10-17/96 0904 812 011 16 105 96 10 17 M12 x 27 20
W-FAZ-IG/A4 M12-20-27/106 0904 812 012 16 105 106 20 27 M12 x 27 20
W-FAZ-IG/A4 M12-30-37/116 0904 812 013 16 105 116 30 37 M12 x 27 20


Screw hexagon head DIN 933

Art. No. Steel grade Fixture Thread Wrench PU


Article description
thickness size size

Pre fastening
tfix ØxlG SW

mm mm Qty.

Typ S M6 x 25 0904 806 120 A4 4-12 M6 x 25 10 100


Typ S M8 x25 0904 808 120 A4 2-8 M8 x 25 13 50
Typ S M10 x 40 0904 810 120 A4 15-19 M10 x 40 17 25
Typ S M12 x 45 0904 812 120 A4 16-21 M12 x 45 19 20
Through fastening

Typ S M6 x 16 0904 806 020 A4 10/20/30 M6 x 16 10 100


Typ S M8 x 18 0904 808 020 A4 10/20/30 M8 x 18 13 50
Typ S M10 x 20 0904 810 020 A4 10/20/30 M10 x 20 17 25
Typ S M12 x 25 0904 812 020 A4 10/20/30 M12 x 25 19 20

14
W-FAZ-IG/A4, W-FAZ-IG/HCR

Countersunk Screw DIN7991

Art. No. Steel grade Fixture Thread Wrench PU


Article description
fixness size size

Pre - fastening
tfix ØxlG SW
mm mm Qty.
Typ SK M6 x 25 0904 806 130 A4 6-14 M6 x 25 Tx 30 100
Typ SK M8 x 30 0904 808 130 A4 9-15 M8 x 30 Tx 40 50
Typ SK M10 x 30 0904 810 130 A4 8-11 M10 x 30 Innen 6-kt. 6mm 25
Typ SK M12 x 35 0904 812 130 A4 9-14 M12 x 35 Innen 6-kt. 8mm 20

Through fastening

Typ SK M6 x 16 0904 806 030 A4 14/24/34 M6 x 16 Tx30 100


Typ SK M8 x 20 0904 808 030 A4 15/25/35 M8 x 20 Tx 40 50
Typ SK M10 x 25 0904 810 030 A4 16/26/36 M10 x 25 Innen6-kt. 6mm 25
Typ SK M12 x 30 0904 812 030 A4 17/27/37 M12 x 30 Innen6-kt. 8mm 20

Cotter-pin installation Through-bolt mounting


R

Setting Tool + +
read
on
Ty p e S
Through-bolt
Type SK Ty p e B Ty p e S Ty p e S K Ty p e B
esistant steel – Anchor diameter mounting M6 M8 M10 M12

++ +
Ty p e B
Pre fastening
Ty p e S Ty p e S K Ty p e B
0904 706 150 0904 708 150 0904 710 150 0904 712 150
washer 1)

ETA-02/0017)
Through fastening
+
rete surface)
0904 706 050 0904 708 050 0904 710 050 0904 712 050

Test Reports Important information!


Please only set the W-FAZ-IG fixing anchor together with the
l

Fire related approval-conformant setting tools (anchor system).


l Hexagon bolts, countersunk head screws, washers, countersunk
Resistance head washers and nuts are specially coated and only permissible
Direct flame effect in anchor system in accordance with ETA-02/0017. Therefore,
F30 – F120 please order separately at the same time 1) (see product
nt information!(ETK-DIN 4102-2: information, Page 3).
) set the W-FAZ-IG
nly 1977-09) Common
fixing anchor together lwith the threaded rods 2) may only be used if the conditions

approval-conformant setting tools (anchor system). specified in the approval ETA-02/0017 (Appendix 5, Table 3)
n bolts, countersunk head screws, washers, countersunk(material quality, dimensions, mechanical properties according
ashers and nuts are specially coated and only to EN 10204:2004) are met.
permissible
r system in accordance with ETA-02/0017. Therefore,l The torque necessary for anchoring can be applied with Würth
rder separately at the same time torque
1) (see wrenches and suitable attachments (insertion open-end
product
on, Page 3). wrench).
n threaded rods 2 ) may only be used if the conditions
d in the approval ETA-02/0017 (Appendix 5, Table 3)2. Advantages
l quality, dimensions, mechanical properties according
l High loads, small axle bases and edge clearances
es, brackets, foot
0204:2004) areplates,
met. supports, l All screws/bolts available in the product line (see product information, Page 3) can be used
ms, stadium seats, etc.
ue necessary for anchoring can be applied for both cotter-pin and through-bolt mounting
with Würth
used in reinforced or non-reinforced l Can be loaded immediately – no wait time
wrenches andC50/60
5 and at most suitableinattachments
accordance (insertion open-end
l Fixed anchor cone with patented plastic coating facilitates reliable later expansion
l Elegant appearance thanks to countersunk head screws for visible fastening with
ed concrete (concrete tensile zone) simultaneous high load-bearing capacity (e.g. railings)
antages
e)
ural stone (without app roval)
l Also suitable for temporary fastening (cotter-pin mounting, e.g. stadium seats for flexible
use – flush with surface without danger of injury)
small axle (e.g.
atic loads basesown andweight,
edge clearances l Reliable installation due to application of prescribed torque
.olts available
façades, in the product line (see product information, Page 3) can be used
railings)
er-pin and through-bolt mounting
ndoor rooms, outdoors
ded
oomsimmediately
(including
– no waitaggressive
if no especially time con- 3. Properties 15
r cone with patented plastic coating facilitates reliable later expansion
l Force-controlled/torque-controlled spreading anchor of A4 stainless steel in the sizes M6,
an be used under especially head screws for visible
earance thanks to countersunk fastening with
M8, M10 and M12
sg.high load-bearing
continuous, capacity
alternating (e.g. railings)
immersion in
e for temporary fastening (cotter-pin mounting, e.g. l Stainless steel A4
stadium seats for and HCR highly corrosion resistant steel, M6 – M12:
flexible
W-HAZ/S
HIGH-PERFORMANCE ANCHOR W-HAZ/S Approved for:
Concrete C20/25 to C50/60
W-HAZ-B
Benefits:
• The bolt is attuned to the sleeve to make this anchor a
reliable specialist for highest shear load demands.
• Various head types allow tidy finishes and avoid risk
W-HAZ-S of injury when using for machine bases.
• The optimized combination of expansion sleeve and
cone bolt allow smallest spacing and thus small
cost-efficient anchor plates.

W-HAZ-SK

Applications: Approvals and Certificates

Technical Data:
Head configuration Inner thread
Environmental conditions Indoor, dry conditions
Material composition Steel, galvanized
Type of fastening Through-fastening
Suitable for fastening metal constructions, metal profit Cracked
Suitable for concrete
less, brackets, foot plates, supports, cable conduits, pipes, Non-cracked concrete
railings, machines, etc.

Thread size 10/M6 12/M8 15/M10 18/M12 24/M16 24/M16L 28/M20


Effective anchorage depth hef [mm] 50 60 71 80 100 115 125
Non-cracked concrete
Tensile C20/25 Nrec [kN] 7.6 9.5 14.3 16.7 23.8 29.7 33.6
C50/60 Nrec [kN] 7.6 13.8 21.9 25.8 36.9 46.0 52.1
B 9.1 14.3 20.6 34.4 48.1 52.0 67.2
Shear ≥ C20/25 Vrec [kN]
S and SK 10.3 17.1 27.4 34.4 48.1 59.3 67.2
Cracked concrete
Tensile C20/25 Nrec [kN] 2.4 5.7 7.6 11.9 17.1 21.0 23.8
C50/60 Nrec [kN] 3.7 8.9 11.8 18.5 26.6 32.5 36.9
B 9.1 14.3 20.6 24.6 34.4 42.4 48.0
Shear ≥ C20/25 Vrec [kN]
S and SK 10.3 16.0 20.6 24.6 34.4 42.4 48.0
1)
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.

Installation:

16
W-HAZ/S
Min. drill
Article description Art. No. Drill dia. hole depth Anchor Fixture Wrench PU
for through Length thickness Size
fastening

do h 2 l tfix SW
mm mm mm mm Qty.
W-HAZ-B/S-0-M6x67 0905 210 101 10 65 67 0 10 100
W-HAZ-B/S-10-M6x77 0905 210 102 10 75 77 10 10 50
W-HAZ-B/S-30-M6x97 0905 210 103 10 95 97 30 10 50
W-HAZ-B/S-50-M6x117 0905 210 104 10 115 117 50 10 50
W-HAZ-B/S-100-M6x167 0905 210 105 10 165 167 100 10 25
W-HAZ-B/S-0-M8x80 0905 212 101 12 80 80 0 13 50
W-HAZ-B/S-10-M8x90 0905 212 102 12 90 90 10 13 50
W-HAZ-B/S-30-M8x110 0905 212 103 12 110 110 30 13 50
W-HAZ-B/S-50-M8x130 0905 212 104 12 130 130 50 13 25
W-HAZ-B/S-100-M8x180 0905 212 105 12 180 180 100 13 25
W-HAZ-B/S-0-M10x96 0905 215 101 15 95 96 0 17 25
W-HAZ-B/S-15-M10x111 0905 215 102 15 110 111 15 17 25
W-HAZ-B/S-25-M10x121 0905 215 103 15 120 121 25 17 25
W-HAZ-B/S-45-M10x141 0905 215 104 15 140 141 45 17 25
W-HAZ-B/S-95-M10x191 0905 215 105 15 190 191 95 17 25
W-HAZ-B/S-0-M12x112 0905 218 101 18 105 112 0 19 20
W-HAZ-B/S-10-M12x122 0905 218 102 18 115 122 10 19 20
W-HAZ-B/S-20-M12x132 0905 218 103 18 125 132 20 19 20
W-HAZ-B/S-40-M12x152 0905 218 104 18 145 152 40 19 20
W-HAZ-B/S-70-M12x182 0905 218 105 18 175 182 70 19 20
W-HAZ-B/S-100-M12x212 0905 218 106 18 205 212 100 19 10
W-HAZ-B/S-0-M16x137 0905 224 101 24 130 137 0 24 10
W-HAZ-B/S-20-M16x157 0905 224 102 24 115 157 20 24 10
W-HAZ-B/S-50-M16x187 0905 224 103 24 180 187 50 24 10
W-HAZ-B/S-100-M16x237 0905 224 104 24 230 237 100 24 5
W-HAZ-B/S-0-M16Lx152 0905 224 111 24 145 152 0 24 10
W-HAZ-B/S-30-M16Lx182 0905 224 113 24 175 182 30 24 10
W-HAZ-B/S-50-M16Lx202 0905 224 115 24 195 202 50 24 10
W-HAZ-B/S-10-M20x181 0905 228 101 28 170 181 10 30 10
W-HAZ-B/S-30-M20x201 0905 228 102 28 190 201 30 30 10
W-HAZ-B/S-60-M20x231 0905 228 103 28 220 231 60 30 5
W-HAZ-B/S-100-M20x271 0905 228 104 28 260 271 100 30 5

17
W-HAZ/S
Article description Drill dia. Min. drill
Art. No. Anchor Fixture Wrench PU
hole depth
Length thick- Size
for through
ness
fastening

do h 2 l tfix SW
mm mm mm mm Qty.

W-HAZ-S/S-0-M6x65 0905 210 001 10 65 65 0 10 100


W-HAZ-S/S-10-M6x75 0905 210 002 10 75 75 10 10 50
W-HAZ-S/S-30-M6x95 0905 210 003 10 95 95 30 10 50
W-HAZ-S/S-50-M6x115 0905 210 004 10 115 115 50 10 50
W-HAZ-S/S-0-M8x77 0905 212 001 12 80 77 0 13 50
W-HAZ-S/S-10-M8x87 0905 212 002 12 90 87 10 13 50
W-HAZ-S/S-30-M8x107 0905 212 003 12 110 107 30 13 50
W-HAZ-S/S-50-M8x127 0905 212 004 12 130 127 50 13 25
W-HAZ-S/S-0-M10x93 0905 215 001 15 95 93 0 17 25
W-HAZ-S/S-15-M10x108 0905 215 002 15 110 108 15 17 25
W-HAZ-S/S-25-M10x118 0905 215 003 15 120 118 25 17 25
W-HAZ-S/S-45-M10x138 0905 215 004 15 140 138 45 17 25
W-HAZ-S/S-95-M10x188 0905 215 005 15 190 188 95 17 25
W-HAZ-S/S-0-M12x107 0905 218 001 18 105 107 0 19 20
W-HAZ-S/S-10-M12x117 0905 218 002 18 115 117 10 19 20
W-HAZ-S/S-20-M12x127 0905 218 003 18 125 127 20 19 20
W-HAZ-S/S-40-M12x147 0905 218 004 18 145 147 40 19 20
W-HAZ-S/S-70-M12x177 0905 218 005 18 175 177 70 19 20
W-HAZ-S/S-0-M16x132 0905 224 001 24 130 132 0 24 10
W-HAZ-S/S-20-M16x152 0905 224 002 24 150 152 20 24 10
W-HAZ-S/S-50-M16x182 0905 224 003 24 180 182 50 24 10
W-HAZ-S/S-0-M16Lx150 0905 224 011 24 145 150 0 24 10
W-HAZ-S/S-30-M16Lx180 0905 224 013 24 175 180 30 24 10
W-HAZ-S/S-50-M16Lx200 0905 224 015 24 195 200 50 24 10
W-HAZ-S/S-10-M20x172 0905 228 001 28 170 172 10 30 10
W-HAZ-S/S-30-M20x192 0905 228 002 28 190 192 30 30 10
W-HAZ-S/S-60-M20x222 0905 228 003 28 220 222 60 30 5
W-HAZ-S/S-100-M20x262 0905 228 004 28 260 262 100 30 5

18
W-HAZ/S
Min. drill Anchor Fixture Wrench
Article description Art. No. Drill dia. PU
hole depth Length thickness Size
for through
fastening

do h 2 l tfix SW
mm mm mm mm Qty.

W-HAZ-SK/S-10-M6x70 0905 210 201 10 75 70 10 4 50


W-HAZ-SK/S-25-M6x85 0905 210 202 10 90 85 25 4 50
W-HAZ-SK/S-40-M6x100 0905 210 203 10 105 100 40 4 50
W-HAZ-SK/S-10-M8x80 0905 212 201 12 90 80 10 5 50
W-HAZ-SK/S-25-M8x95 0905 212 202 12 105 95 25 5 50
W-HAZ-SK/S-50-M8x120 0905 212 203 12 130 120 50 5 25
W-HAZ-SK/S-10-M10x95 0905 215 201 15 105 95 10 6 25
W-HAZ-SK/S-25-M10x110 0905 215 202 15 120 110 25 6 25
W-HAZ-SK/S-35-M10x120 0905 215 203 15 130 120 35 6 25
W-HAZ-SK/S-50-M10x135 0905 215 204 15 145 135 50 6 25
W-HAZ-SK/S-20-M12x115 0905 218 203 18 125 115 20 8 20
W-HAZ-SK/S-40-M12x135 0905 218 204 18 145 135 40 8 20

19
W-HAZ/A4
HIGH-PERFORMANCE ANCHOR W-HAZ/A4
Approved for:
W-HAZ-B/A4 Concrete C20/25 to C50/60

Benefits:
• The bolt is attuned to the sleeve to make this anchor a
W-HAZ-S/A4 reliable specialist for highest shear load demands.
• Various head types allow tidy finishes and avoid risk
of injury when using for machine bases.
• The optimized combination of expansion sleeve and
cone bolt allow smallest spacing and thus small cost
efficient anchor plates.
W-HAZ-SK/A4

Approvals and Certificates

Applications:

Technical Data:
Head configuration Inner thread
Environmental conditions Indoor, Outdoor
Material composition A4 stainless steel
Type of fastening Through-fastening
Suitable for Cracked concrete
Metal constructions, metal profiles, brackets, foot plates, supports, cable Non-cracked concrete
conduits, pipes, railings, machines, etc.

Thread size 12/M8 15/M10 18/M12 24/M16


Effective anchorage depth hef [mm] 60 71 80 100
Non-cracked concrete
Tensile C20/25 Nrec [kN] 7.6 11.9 16.7 24.0
B 11.8 18.5 25.8 37.3
C50/60 Nrec [kN]
S and K 9.9 15.7 22.9 37.3
B 13.7 21.1 34.4 48.1
Shear ≥ C20/25 Vrec [kN]
S and K 12.6 19.4 32.6 48.1
Cracked concrete
Tensile C20/25 Nrec [kN] 4.3 7.6 12.3 17.1
C50/60 Nrec [kN] 6.6 11.8 19.1 26.6
B 13.7 20.6 24.6 34.4
Shear ≥ C20/25 Vrec [kN]
S and K 12.6 19.4 24.6 34.4
1)
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.

Installation:

20
W-HAZ/A4

Min. drill

Article description Art. No. Drill dia. Anchor Fixture Wrench PU
hole depth Size
Length thickness
for through
fastening

do h 2 l tfix SW
mm mm mm mm Qty.
W-HAZ-B/A4-10-M8x90 5932 612 102 12 90 90 10 13 50
W-HAZ-B/A4-30-M8x110 5932 612 103 12 110 110 30 13 50
W-HAZ-B/A4-15-M10x111 5932 615 102 15 110 111 15 17 25
W-HAZ-B/A4-25-M10x121 5932 615 103 15 120 121 25 17 25
W-HAZ-B/A4-20-M12x132 5932 618 103 18 125 132 20 19 20

W-HAZ-S/A4-10-M8x90 5932 612 002 12 90 90 10 13 50


W-HAZ-S/A4-30-M8x110 5932 612 003 12 110 110 30 13 50
W-HAZ-S/A4-15-M10x111 5932 615 002 15 110 111 15 17 25
W-HAZ-S/A4-25-M10x121 5932 615 003 15 120 121 25 17 25
W-HAZ-S/A4-20-M12x132 5932 618 003 18 125 132 20 19 20

W-HAZ-SK/A4-10-M8x80 5932 612 201 12 90 80 10 5 50


W-HAZ-SK/A4-25-M8x95 5932 612 202 12 105 95 25 5 50
W-HAZ-SK/A4-25-M10x110 5932 615 202 15 120 110 25 6 25
W-HAZ-SK/A4-20-M12x115 5932 618 203 18 125 115 20 8 20

Marking of setting depth

21
W-VIZ/S and WIT-VM 100
Individual attachment:
Cracked and non-cracked concrete

Galvanised steel

Proof of performance

Permissions Test reports Pass-through


mounting Drill hole cleaning
Clean the drill hole: 2x blow-out, 2x mechanical brush-out,
European (M10 to M24) 2x blow-out
Technical Approval Fire resistance If the drill hole is M20 or larger, blow out with compressed air using the
Option 1 appropriate compressed air nozzles
for cracked and non-cracked Direct
concrete and seismic ame effect
performance category C2 • Hardened injection mortar largely seals off the drill hole
• Attachment with low expansion pressure allows small axial and edge
Ring gap between clearances
anchor rod and
attached part must
• Geometry of anchor rod allows safe subsequent expansion performance
be lled with WIT- • Cartridge can be reused by replacing static mixer or by reclosing with sealing
VM 100 or WIT- cap
EXPRESS mortar.
3. Properties
1. Areas of application • Torque-controlled expanding anchors made of galvanised steel
• Individual attachment: Standard concrete C20/25 to C50/60 • Approval: ETA-04/0095 for individual attachment
(cracked and non-cracked concrete) Option 1, cracked and non-cracked concrete, seismic performance
• Suitable for fastening metal structures, metal profiles, brackets, base plates, category C2
supports, railings, wooden structures, beams etc. • Fire resistance: F30, F60, F90 and F120
• The temperature in the area surrounding the mortar must not exceed +50°C Exposure to fire according to DIN 4102-02: 1977-09
or +72°C, short term +80°C or +120°C (uniform temperature curve)
• W-VIZ/S (galvanised steel) can be used in dry indoor areas

2. Benets
• Through-bolt and cotter-pin mounting
• Highest load-bearing capacity, low axial and edge clearance
• Shallow drilling hole depth with deep anchoring depth
• The drill holes can be produced by the hammer drilling process (M8 to M24)
and diamond drilling process (M10 to M24)

Setting instructions (cotter-pin mounting M8 to M24):

Produce drilled hole Check diameter of Clean drill hole (blow out Screw mixer onto Before use, press out Fill composite mortar Press in anchor rod Visual check of Comply with Mount component,
cleaning brushes 2 x, brush out mechanically cartridge approx. 10 cm cord. starting from base of up to drill hole base mortar lling hardening time of apply installation
2 x, blow out 2 x), with Do not use this initial drill hole while turning slightly quantity, setting composite mortar torque
M20 and larger, blow mortar! depth marking
out with compressed air
(compressed-air nozzle!)

22
W-VIZ/S and WIT-VM 100
Anchor characteristics
M8 M8 M10 M10 M12 M12 M12 M12 M12 M12
Anchor diameter [mm]
hef 40 hef 50 hef 60 hef 75 hef 70 hef 80 hef 95 hef 100 hef 110 hef 125
Minimum component thickness hmin ≥ [mm] 80 80 100 110/100 110
5) 110 130/125 130
5) 140 160
Minimal axis distance
smin ≥ [mm] 40 40 40 40 40 50 40 50 55 55 40 55 40 55 50 806) 50 806) 50 806)
cracked concrete non-cracked concrete
Minimal edge clearance
cmin ≥ [mm] 40 40 40 40 40 50 40 50 55 55 50 55 50 55 50 55 50 55 50 55
cracked concrete non-cracked concrete
Axial spacing scr,N [mm] 120 150 180 225 210 240 285 300 330 375
Edge spacing ccr,N [mm] 60 75 90 112.5 105 120 142.5 150 165 187.5
Effective anchoring depth hef ≥ [mm] 40 50 60 75 70 80 95 100 110 125
Nom. drill dia. d0 [mm] 10 10 12 12 14 14 14 14 14 14
Drill hole depth h0 ≥ [mm] 42 55 65 80 75 85 100 105 115 130
Through-hole in the component being connected
df ≤ [mm] 9 9 12 12 14 14 14 14 14 14
– cotter-pint mounting
Through-hole in the component being connected
df ≤ [mm] – – 14 14 16 16 16 16 16 16
– pass-through mounting7)
Installation torque Tinst = [Nm] 10 10 15 15 25 25 25 30 30 30
Cleaning brush dia. D ≥ [mm] 10.8 10.8 13.0 13.0 15.0 15.0 15.0 15.0 15.0 15.0

Performance data
M8 M8 M10 M10 M12 M12 M12 M12 M12 M12
Anchor diameter [mm]
hef 40 hef 50 hef 60 hef 75 hef 70 hef 80 hef 95 hef 100 hef 110 hef 125
50°C3) /
Tensile zone 4.3 6.1 8.0 11.1 10.0 12.3 15.9 17.1 19.8 24.0
80°C4)
(cracked concrete C20/252),
72°C3) /
Permissible central tensile

s ≥ 3 hef, c ≥ 1.5 hef) 2.4 3.6 5.7 5.7 7.6 9.5 9.5 14.3 14.3 14.3
120°C4)
without edge inuence

Pressure zone Nperm. [kN] 50°C3) /


3.6 4.3 7.6 9.5 9.5 17.2 14.3 19.1 16.7 19.1
(non-cracked concrete C20/252)) = 80°C4)
of a single anchor

Minimum axial and edge spacing C20/252) 72°C3) /


(scr,sp ≥ 3 hef, ccr,sp ≥ 1.5 hef) 2.9 4.3 7.6 7.6 7.6 11.9 11.9 14.3 14.3 14.3
120°C4)
Pressure zone
(non-cracked concrete C20/252)) 50°C3) /
4.3 8.5 11.2 11.9 14.1 17.2 19.1 24.0 23.8 23.8
load1)

maximum carrying capacity 80°C4)


(scr,sp and ccr,sp see permit)
Tensile zone
anchor without
edge inuence

(cracked concrete C20/252), 8.0 8.0 12.0 12.0 19.4 19.4 19.4 19.4 19.4 19.4
transverse

c ≥ 10 hef) Vperm. [kN] =


of a single

Pressure zone C20/252)


Perm.

load1)

(non-cracked concrete C20/252), 8.0 8.0 12.0 12.0 19.4 19.4 19.4 19.4 19.4 19.4
c ≥ 10 hef)
Permissible bending moment Tperm. [Nm] 17.1 17.1 34.3 34.3 60 60 60 60 60 60
F30 [kN] – 3.0 7.0 – – 10.0 – 10.0 – –
F60 [kN] – 0.3 0.95 – – 2.8 – 2.8 – –
Fire resistance class
F90 [in kN] – – 0.3 – – 1.35 – 1.35 – –
F120 [kN] – – – – – 0.8 – 0.8 – –

Würth system components 1) The partial safety factors of the resistances regulated in the 3) Maximum long-term temperature.
approval and a partial safety factor of the effects of γF = 1.4 4) Maximum short-term temperature.
have been taken into account. Please refer to the European 5) The back of the concrete component must be checked to ensure
Technical Approval Guidelines (ETAG), Appendix C, for that no chipping has occurred during drilling
information on combining tensile and transverse loads, edge (see ETA-04/0095).
inuence and groups of anchors. 6) Min. axis distance smin = 55 mm for edge clearance c ≥ 80 mm.
2) The concrete has normal reinforcement. Higher values are 7) The ring gap in the attached part must be completely lled with
possible for higher concrete strengths. excess mortar after the setting.

23
W-VIZ/S and WIT-VM 100
Anchor characteristics
M16 M16 M16 M16 M20 M20 M20 M24 M24
Anchor diameter [mm]
hef 90 hef 105 hef 125 hef 145 hef 115 hef 170 hef 190 hef 200 hef 225
Minimum component thickness hmin ≥ [mm] 130 150 170/160 5) 190/1805) 160 230/220 5) 250/2405) 270/260 5) 300/2905)
Minimal axis distance
smin ≥ [mm] 50 50 50 60 60 60 60 60 80 80 80 80 80 80 80 105 80 105
cracked concrete non-cracked concrete
Minimal edge clearance
cmin ≥ [mm] 50 50 50 60 60 60 60 60 80 80 80 80 80 80 80 105 80 105
cracked concrete non-cracked concrete
Axial spacing scr,N [mm] 270 315 375 435 345 510 570 600 675
Edge spacing ccr,N [mm] 135 157.5 187.5 217.5 172.5 255 285 300 337.5
Effective anchoring depth hef ≥ [mm] 90 105 125 145 115 170 190 200 225
Nom. drill dia. d0 [mm] 18 18 18 18 22 24 24 26 26
Drill hole depth h0 ≥ [mm] 98 113 133 153 120 180 200 215 240
Through-hole in the component being connected
df ≤ [mm] 18 18 18 18 22 24 24 26 26
– cotter-pint mounting
Through-hole in the component being connected
df ≤ [mm] 20 20 20 20 24 26 26 28 28
– pass-through mounting6)
Installation torque Tinst ≤ [Nm] 50 50 50 50 80 80 80 120 120
Cleaning brush dia. D ≥ [mm] 19 19 19 19 23 25 25 27 27

Performance data
M16 M16 M16 M16 M20 M20 M20 M24 M24
Anchor diameter [mm]
hef 90 hef 105 hef 125 hef 145 hef 115 hef 170 hef 190 hef 200 hef 225
50°C3) /
Tensile zone 14.6 18.4 24.0 29.9 21.1 38.0 44.9 48.5 57.9
80°C4)
(cracked concrete C20/252),
72°C3) /
Permissible central tensile

s ≥ 3 hef, c ≥ 1,5 hef) 9.5 14.3 23.8 23.8 14.3 28.6 28.6 35.7 35.7
120°C4)
without edge inuence

Pressure zone Nperm. [kN] 50°C3) /


19.1 23.8 23.8 28.6 29.6 53.2 54.8 67.9 66.7
(non-cracked concrete C20/252)) = 80°C4)
of a single anchor

Minimum axial and edge spacing C20/252) 72°C3) /


(scr,sp ≥ 3 hef, ccr,sp ≥ 1.5 hef) 11.9 16.7 23.8 23.8 19.1 35.7 35.7 45.2 45.2
120°C4)
Pressure zone
(non-cracked concrete C20/252)) 50°C3) /
20.5 25.8 33.5 35.7 29.6 53.2 62.9 67.9 81.0
load1)

maximum carrying capacity 80°C4)


(scr,sp and ccr,sp see permit)
Tensile zone
Perm. transverse

(cracked concrete C20/252), 29.3 36.0 36.0 36.0 35.7 76.0 85.1 97.0 101.7
without edge

c ≥ 10 hef) Vperm. [kN] =


of a single

C20/252)
inuence

Pressure zone
anchor
load1)

(non-cracked concrete C20/252), 36.0 36.0 36.0 36.0 35.7 85.1 85.1 101.7 101.7
c ≥ 10 hef)
Permissible bending moment Tperm. [Nm] 152.0 152.0 152.0 152.0 200.0 296.6 296.6 512.0 512.0
F30 [kN] – – 12.0 – – 17.0 – 24.5 –
F60 [kN] – – 6.4 – – 8.8 – 12.7 –
Fire resistance class
F90 [in kN] – – 4.4 – – 6.0 – 8.6 –
F120 [kN] – – 3.4 – – 4.5 – 6.5 –

Würth system components 1) The partial safety factors of the resistances regulated in the 3) Maximum long-term temperature.
approval and a partial safety factor of the effects of γF = 1.4 4) Maximum short-term temperature.
have been taken into account. Please refer to the European 5) The back of the concrete component must be checked to
Technical Approval Guidelines (ETAG), Appendix C, for ensure that no chipping has occurred during drilling
information on combining tensile and transverse loads, edge (see ETA-04/0095).
inuence and groups of anchors. 6) The ring gap in the attached part must be completely lled
2) The concrete has normal reinforcement. Higher values are with excess mortar after the setting.
possible for higher concrete strengths.

24
W-VIZ/S and WIT-VM 100

Dimensions of W-VIZ-A/S Anchor Bar,


galvanized steel

Designation Anchor Effective Attachment Total Drill bit Drill hole No. attachment Approval Art. No. P.
dia. anchoring height tfix length L nominal depth h0 ≥ points per cartridge ETA Qty.
depth hef [mm] [mm] dia. d0 [mm] Approx. qty.
[mm] [mm]
40 15 65 42 75 0905 440 811
15 80 0905 440 801
M8 10
50 30 95 55 62 0905 440 802
45 110 0905 440 803
10 85 0905 441 001
20 95 0905 441 002
60 30 105 65 42 0905 441 003
M10 12
60 135 0905 441 004
100 175 0905 441 005
75 20 110 80 36 0905 441 011
70 25 115 75 37 0905 441 211
10 110 0905 441 201
25 125 0905 441 202
50 150 0905 441 203
80 85 30
100 200 0905 441 204
10
125 225 0905 441 205
M12 165 265 14 0905 441 206
95 25 140 100 0905 441 221
25 145 0905 441 251
W-VIZ-A/S 28 ETA-04/0095
100 60 180 105 0905 441 252
100 220 0905 441 253*
110 25 155 115 0905 441 261*
27
125 25 170 130 0905 441 271
90 30 145 98 23 0905 441 611
105 30 160 113 20 0905 441 621
30 180 0905 441 601
M16 60 210 18 0905 441 602
125 133 18
100 250 0905 441 603
165 315 0905 441 604
145 30 200 153 16 0905 441 631
115 30 175 22 120 12 0905 442 011*
25 230 0905 442 001
M20 170 50 255 180 0905 442 002
24 8
100 305 0905 442 003
5
190 50 275 200 0905 442 021
50 290 0905 442 401
200 215 7
M24 100 340 26 0905 442 402*
225 50 315 240 6 0905 442 411*

Drill hole cleaning


Anchor diameter [mm] M8 M10 M12 M16 M20 M20 M24
hef 115
Art. No.
Cleaning Brush (steel) 0905 499 001 0905 499 002 0905 499 003 0905 499 004 0905 499 007 0905 499 005 0905 499 006
P. Qty. = 1
Art. No. Hexagon: Art. No. 0905 499 101
Machine Mounting
P. Qty. = 1 SDS-plus Art. No. 0905 499 102

Art. No.
Extension 0905 499 111
P. Qty. = 1
Art. No.
Brush Template 0905 499 099
P. Qty. = 1
Art. No. Blow-Out Pump: Art. No. 0903 990 001
Blow-Out Pump Compressed-Air Nozzle1): Art No. 0905 499 201
P. Qty. = 1 M8 Reduction Attachment for blow-out pump: Art. No. 0905 499 202
Compressed-air nozzle designed for Blow-Out Gun Art. No. 0714 92 13
1)

*S-24 ordering not available.

25
W-VIZ/A4 and WIT-VM 100
Individual attachment:
Cracked and non-cracked concrete

W-VIZ/A4 Stainless steel A4

Proof of performance

Permissions Test reports Pass-through


mounting Drill hole cleaning
Clean the drill hole: 2x blow-out, 2x mechanical brush-out,
European (M10 to M24) 2x blow-out
Technical Approval Fire resistance If the drill hole is M20 or larger, blow out with compressed air using the
Option 1 appropriate compressed air nozzles
for cracked and non-cracked Direct
concrete and seismic ame effect
performance category C2 2. Benets
• Through-bolt and cotter-pin mounting
Ring gap between • Highest load-bearing capacity, low axial and edge clearance
anchor rod and • Shallow drilling hole depth with deep anchoring depth
attached part must • The drill holes can be produced by the hammer drilling process
be lled with (M8 to M24) and diamond drilling process (M10 to M24)
WIT-VM 100 or
• Hardened injection mortar largely seals off the drill hole
WIT-EXPRESS mortar.
• Attachment with low expansion pressure allows small axial and edge
1. Areas of application clearances
• Individual attachment: Standard concrete C20/25 to C50/60 • Geometry of anchor bar allows safe subsequent expansion performance
(cracked and non-cracked concrete) • Cartridge can be reused by replacing static mixer or by reclosing with sealing
• Suitable for fastening metal structures, metal profiles, brackets, base plates, cap
supports, railings,
wooden structures, beams etc. 3. Properties
• The temperature in the area surrounding the mortar must not exceed +50°C or • Torque-controlled expanding anchors made of stainless steel A4.
+72°C, short term +80°C or +120°C
• W-VIZ/A4 (stainless steel A4) can be used in dry indoor areas, outdoors • Approval: ETA-04/0095 for individual attachment
(including in industrial atmospheres and coastal areas) or in wet rooms Option 1, cracked and non-cracked concrete, seismic performance
category C2
• Fire resistance: F30, F60, F90 and F120
Exposure to fire according to DIN 4102-02: 1977-09
(uniform temperature curve)

Setting instructions (cotter-pin mounting M8 to M24):

Produce drilled hole Check diameter of Clean drill hole (blow out Screw mixer onto Before use, press out Fill composite mortar Press in anchor rod Visual check of Comply with Mount component,
cleaning brushes 2 x, brush out mechanically cartridge approx. 10 cm cord. starting from base of up to drill hole base mortar lling hardening time of apply installation
2 x, blow out 2 x), with Do not use this initial drill hole while turning slightly quantity, setting composite mortar torque
M20 and larger, blow mortar! depth marking
out with compressed air
(compressed-air nozzle!)

26
W-VIZ/A4 and WIT-VM 100

Anchor characteristics W-VIZ/A4 see ETA-04/0095


M8 M8 M10 M10 M12 M12 M12 M12 M12 M12
Anchor diameter [mm]
hef 40 hef 50 hef 60 hef 75 hef 70 hef 80 hef 95 hef 100 hef 110 hef 125
Minimum component thickness hmin ≥ [mm] 80 80 100 110/100 110
5) 110 130/125 130
5) 140 160
Minimal axis distance
smin ≥ [mm] 40 40 40 40 40 50 40 50 55 55 40 55 40 55 50 806) 50 806) 50 806)
cracked concrete non-cracked concrete
Minimal edge clearance
cmin ≥ [mm] 40 40 40 40 40 50 40 50 55 55 50 55 50 55 50 55 50 55 50 55
cracked concrete non-cracked concrete
Axial spacing scr,N [mm] 120 150 180 225 210 240 285 300 330 375
Edge spacing ccr,N [mm] 60 75 90 112.5 105 120 142.5 150 165 187.5
Effective anchoring depth hef ≥ [mm] 40 50 60 75 70 80 95 100 110 125
Nom. drill dia. d0 [mm] 10 10 12 12 14 14 14 14 14 14
Drill hole depth h0 ≥ [mm] 42 55 65 80 75 85 100 105 115 130
Through-hole in the component being connected
df ≤ [mm] 9 9 12 12 14 14 14 14 14 14
– cotter-pint mounting
Through-hole in the component being connected
df ≤ [mm] – – 14 14 16 16 16 16 16 16
– pass-through mounting7)
Installation torque Tinst ≤ [Nm] 10 10 15 15 25 25 25 30 30 30
Cleaning brush dia. D ≥ [mm] 10.8 10.8 13.0 13.0 15.0 15.0 15.0 15.0 15.0 15.0

Performance data W-VIZ/A4 see ETA-04/0095


M8 M8 M10 M10 M12 M12 M12 M12 M12 M12
Anchor diameter [mm]
hef 40 hef 50 hef 60 hef 75 hef 70 hef 80 hef 95 hef 100 hef 110 hef 125
50°C3) /
Tensile zone 4.3 6.1 8.0 11.1 10.0 12.3 15.9 17.1 19.8 24.0
80°C4)
(cracked concrete C20/252),
72°C3) /
Permissible central tensile

s ≥ 3 hef, c ≥ 1.5 hef) 2.4 3.6 5.7 5.7 7.6 9.5 9.5 14.3 14.3 14.3
120°C4)
without edge inuence

Pressure zone Nperm. [kN] 50°C3) /


3.6 4.3 7.6 9.5 9.5 17.2 14.3 19.1 16.7 19.1
(non-cracked concrete C20/252)) = 80°C4)
of a single anchor

Minimum axial and edge spacing C20/252) 72°C3) /


(scr,sp ≥ 3 hef, ccr,sp ≥ 1.5 hef) 2.9 4.3 7.6 7.6 7.6 11.9 11.9 14.3 14.3 14.3
120°C4)
Pressure zone
(non-cracked concrete C20/252)) 50°C3) /
4.3 8.5 11.2 11.9 14.1 17.2 19.1 24.0 23.8 23.8
load1)

maximum carrying capacity 80°C4)


(scr,sp and ccr,sp see permit)
Tensile zone
anchor without
edge inuence

(cracked concrete C20/252), 8.6 8.6 13.1 13.1 19.4 19.4 19.4 19.4 19.4 19.4
transverse

c ≥ 10 hef) Vperm. [kN] =


of a single

Pressure zone C20/252)


Perm.

load1)

(non-cracked concrete C20/252), 8.6 8.6 13.1 13.1 19.4 19.4 19.4 19.4 19.4 19.4
c ≥ 10 hef)
Permissible bending moment Tperm. [Nm] 17.1 17.1 34.3 34.3 60 60 60 60 60 60
F30 [kN] – 3.0 7.0 – – 10.0 – 10.0 – –
F60 [kN] – 0.3 0.95 – – 2.8 – 2.8 – –
Fire resistance class
F90 [in kN] – – 0.3 – – 1.35 – 1.35 – –
F120 [kN] – – – – – 0.8 – 0.8 – –

Würth system components 1) The partial safety factors of the resistances regulated in the 3) Maximum long-term temperature.
approval and a partial safety factor of the effects of γF = 1.4 4) Maximum short-term temperature.
have been taken into account. Please refer to the European 5) The back of the concrete component must be checked to ensure
Technical Approval Guidelines (ETAG), Appendix C, for that no chipping has occurred during drilling
information on combining tensile and transverse loads, edge (see ETA-04/0095).
inuence and groups of anchors. 6) Min. axis distance s
min = 55 mm for edge clearance c ≥ 80 mm.
2) The concrete has normal reinforcement. Higher values are 7) The ring gap in the attached part must be completely lled with

possible for higher concrete strengths. excess mortar after the setting.

27
W-VIZ/A4 and WIT-VM 100
Anchor characteristics W-VIZ/A4 see ETA-04/0095
M16 M16 M16 M16 M20 M20 M20 M24 M24
Anchor diameter [mm] hef 90 hef 105 hef 125 hef 145 hef 115 hef 170 hef 190 hef 200 hef 225
Minimum component thickness hmin ≥ [mm] 130 150 170/1605) 190/1805) 160 230/2205) 250/2405) 270/2605) 300/2905)
Minimal axis distance
smin ≥ [mm] 50 50 50 60 60 60 60 60 80 80 80 80 80 80 80 105 80 105
cracked concrete non-cracked concrete
Minimal edge clearance
cmin ≥ [mm] 50 50 50 60 60 60 60 60 80 80 80 80 80 80 80 105 80 105
cracked concrete non-cracked concrete
Axial spacing scr,N [mm] 270 315 375 435 345 510 570 600 675
Edge spacing ccr,N [mm] 135 157.5 187.5 217.5 172.5 255 285 300 337.5
Effective anchoring depth hef ≥ [mm] 90 105 125 145 115 170 190 200 225
Nom. drill dia. d0 [mm] 18 18 18 18 22 24 24 26 26
Drill hole depth h0 ≥ [mm] 98 113 133 153 120 180 200 215 240
Through-hole in the component being connected
df ≤ [mm] 18 18 18 18 22 24 24 26 26
– cotter-pint mounting
Through-hole in the component being connected
df ≤ [mm] 20 20 20 20 24 26 26 28 28
– pass-through mounting6)
Installation torque Tinst ≤ [Nm] 50 50 50 50 80 80 80 120 120
Cleaning brush dia. D ≥ [mm] 19 19 19 19 23 25 25 27 27

Performance data W-VIZ/A4 see ETA-04/0095


Anchor diameter [mm] M16 M16 M16 M16 M20 M20 M20 M24 M24
hef 90 hef 105 hef 125 hef 145 hef 115 hef 170 hef 190 hef 200 hef 225
50°C3) /
Tensile zone 80°C4) 14.6 18.4 24.0 29.9 21.1 38.0 44.9 48.5 57.9
(cracked concrete C20/252),
72°C3) /
Permissible central tensile

s ≥ 3 hef, c ≥ 1,5 hef) 9.5 14.3 23.8 23.8 14.3 28.6 28.6 35.7 35.7
120°C4)
without edge inuence

Pressure zone Nperm. [kN] 50°C3) / 19.1 23.8 23.8 28.6 29.6 53.2 54.8 67.9 66.7
(non-cracked concrete C20/252)) 80°C4)
of a single anchor

=
Minimum axial and edge spacing C20/252) 72°C3) /
(scr,sp ≥ 3 hef, ccr,sp ≥ 1.5 hef) 11.9 16.7 23.8 23.8 19.1 35.7 35.7 45.2 45.2
120°C4)
Pressure zone
(non-cracked concrete C20/252)) 50°C3) /
20.5 25.8 33.5 35.7 29.6 53.2 62.9 67.9 81.0
load1)

maximum carrying capacity 80°C4)


(scr,sp and ccr,sp see permit)
Tensile zone
of a single anchor
Perm. transverse

(cracked concrete C20/252), 29.3 36.0 36.0 36.0 42.3 74.9 74.9 89.1 89.1
without edge

c ≥ 10 hef) Vperm. [kN] =


Pressure zone C20/252)
inuence

(non-cracked concrete C20/252), 36.0 36.0 36.0 36.0 43.9 74.9 74.9 89.1 89.1
load1)

c ≥ 10 hef)
Permissible bending moment Tperm. [Nm] 152.0 152.0 152.0 152.0 231.6 259.4 259.4 448.0 448.0
F30 [kN] – – 12.0 – – 17.0 – 24.5 –
F60 [kN] – – 6.4 – – 8.8 – 12.7 –
Fire resistance class
F90 [in kN] – – 4.4 – – 6.0 – 8.6 –
F120 [kN] – – 3.4 – – 4.5 – 6.5 –

Würth system components 1) The partial safety factors of the resistances regulated in the 3) Maximum long-term temperature.
approval and a partial safety factor of the effects of γF = 1.4 4) Maximum short-term temperature.
have been taken into account. Please refer to the European Tech- 5) The back of the concrete component must be checked to ensure

nical Approval Guidelines (ETAG), Appendix C, for information that no chipping has occurred during drilling (see ETA-
on combining tensile and transverse loads, edge inuence and 04/0095).
groups of anchors. 6) The ring gap in the attached part must be completely lled with
2) The concrete has normal reinforcement. Higher values are possi- excess mortar after the setting.
ble for higher concrete strengths.

28
W-VIZ/A4 and WIT-VM 100
Anchor bar dimensions: W-VIZ-A/A4, A4 stainless steel

Designa- Anchor Effective Attach- Total Drill bit Drill hole No. attach- Approval Art. No. P.
tion dia. anchoring ment length L nominal depth h0 ≥ ment points ETA Qty.
depth hef height [mm] dia. d0 [mm] per cartridge
[mm] tfix [mm] Approx. qty.
[mm]
40 15 65 42 75 0905 450 811
15 80 0905 450 801
M8 10
50 30 95 55 62 0905 450 802
45 110 0905 450 803
10 85 0905 451 001
20 95 0905 451 002
60 30 105 65 42 0905 451 003
M10 12
60 135 0905 451 004
100 175 0905 451 005
75 20 110 80 36 0905 451 011
70 25 115 75 37 0905 451 211
10 110 0905 451 201
25 125 0905 451 202
50 150 0905 451 203
80 85 30
100 200 0905 451 204
125 225 0905 451 205 10
165 265 0905 451 206
M12 95 25 140 14 100 0905 451 221
25 145 0905 451 251
60 180 28 0905 451 252
100 105
W-VIZ-A/A4 100 220 ETA-04/0095 0905 451 253*

110 25 155 115 0905 451 261*


27
125 25 170 130 0905 451 271
90 30 145 98 23 0905 451 611
105 30 160 113 20 0905 451 621
30 180 0905 451 601
M16 60 210 18 0905 451 602
125 133 18
100 250 0905 451 603
165 315 0905 451 604
145 30 200 153 16 0905 451 631
115 30 175 22 120 12 0905 452 011*
25 230 0905 452 001
M20
170 50 255 180 0905 452 002
24 8
100 305 0905 452 003
190 50 275 200 0905 452 021 5
50 290 0905 452 401
200 215 7
100 340 0905 452 402*
M24 26
225 50 315 240 6 0905 452 411*

29
WIT-VM 100 for W-VIZ/S, W-VIZ/A4
WIT-PM 100 Injection Mortar (temperature in anchoring base ≥ –5°C) 1 2

WIT-Express Injection Mortar (quick curing, temperature in anchoring base ≥ –5°C)

Fig. Designation Contents [ml] Scope of delivery Art. No. P. Qty.


1 WIT-VM 100 0905 440 003
330 Mortar cartridge of 330 ml & 1 static mixer 1/12
2 WIT-Express 0903 420 303

Accessories
Designation Appearance Art. No. P. Qty.

Application Gun 0891 003

HandyMax® Application Gun 0891 007

Static Mixer 0903 420 001


10
Static Mixer Extension 0903 420 004

30
W-HD
Benefits:
• Quick and easy installation - no special tools needed
• Can be loaded immediately – no waiting time
• Maximum flexibility
• Fast and easy installation

Approved for:

Applications:

Technical Data:
Head configuration Inner thread
Environmental conditions Indoor, Outdoor
Material composition Steel, galvanized
Type of fastening Pre fastening
Suitable for Hollow core concrete slabs
Suitable for fastening metal constructions, metal
profiles, brackets, foot plates, supports, cable
conduits, pipes, railings, machines, etc.

Characteristic Values:
Size M6 M8 M10 M12
Drill diameter d0 [mm] 10 12 16 18
Drill hole depth h0 [mm] 50 55 60 70
Anchor length hnom [mm] 40 45 53 58
Through-hole in
df ≤ [mm] 7 9 12 14
Anchor plate
Installation torque Tinst [Nm] 10 20 30 40

Anchor Dimensions:
Sleeve length l (mm) 30 35 40 45
Screw length min lS [mm] 42 + tfix 47 + tfix 55 + tfix 61 + tfix
Threaded bolt length min lB [mm] 47 + tfix 53 + tfix 63 + tfix 71 + tfix
Designation W-HD M6 W-HD M8 W-HD M10 W-HD M12
W-HD Art. No 0905 120 601 0905 120 801 0905 120 001 0905 121 201
(Galvanised Steel)
Packing Unit P. Qty. 50 50 50 25
Installation:

31
W-HD
Performance data
Size M6 M8 M10 M12
Web thickness du ≥ [mm] 25 30 40 50 25 30 40 50 25 30 40 50 25 30 40 50
Axial spacing scr≥ [mm] 300
Individual Anchors
Permissible load Fperm [kN] ≥ C45/55 0.7 0.9 2.0 2.9 0.7 0.9 2.0 3.6 0.9 1.2 3.0 3.6 1.0 1.2 3.0 4.3
oblique pull at every angle

Hollow prestr. concrete plates


Tensile, transverse and
Permissible load

Edge spacing ccr ≥ 150 mm ccr ≥ [mm] 150


Axial spacing scr ≥ 300 mm
Permissible load Fperm [kN] ≥ C45/55 0.35 0.8 1.8 2.4 0.35 0.8 1.8 3.0 0.8 1.0 2.7 3.0 0.8 1.0 2.7 3.6
Hollow prestr. concrete plates
Min. edge spacing cmin ≥ 100 mm
cmin ≥ [mm] 100
Axial spacing scr ≥ 300 mm

Anchor pair
Permissible load Fperm [kN] ≥ C45/55 0.7 1.4 2.6 3.9 0.7 1.4 2.6 4.8 1.1 2.0 4.8 4.8 1.1 2.0 4.8 5.7
Tensile, transverse and oblique

Hollow prestr. concrete plates


smin ≥ [mm] 70 80 100 100 70 80 100 100 70 80 100 100 70 80 100 100
Permissible load

pull at every angle

Edge spacing ccr ≥ 150 mm


Min. axial spacing smin
ccr ≥ [mm] 150
Permissible load Fperm [kN] ≥ C45/55 0.35 1.25 2.35 3.2 0.35 1.25 2.35 4.0 0.9 1.8 4.3 4.3 1.0 1.8 4.3 4.8
Hollow prestr. concrete plates
Min. edge spacing cmin ≥ 100 mm
smin ≥ [mm] 70 80 100 100 70 80 100 100 70 80 100 100 70 80 100 100
Min. axial spacing smin
cmin ≥ [mm] 100
Bending moment (5.8) M [Nm] - 10.7 21.4 37.4
Bending moment (8.8) M [Nm] 4.4 17.1 34.2 59.8

Use the Screw Use the threaded rod

32
W-FA/S, W-FA/F
FIXANCHOR W-FA/S, W-FA/F
W-FA/S Approved for:
Concrete C20/25 to C50/60

Benefits:
•With a few blows the anchor is easy and fast to
W-FA/F install.
•The long thread allows levelling of unevenness and
can be used to assemble stand-off fixations.
• Two approved anchorage depth broaden the
application spectrum.
• Its approval guarantees the safe function even
Machine Setting Tool under highest load requirements.
Art. No. 0904 908 016

Applications: Approvals and Certificates:

Technical Data:
Head configuration Externally threaded
Environmental conditions Indoor, dry conditions
Material composition Steel, galvanized
Type of fastening Through-fastening

Suitable for Non-cracked concrete

Metal structures, metal profiles, brackets, foot plates, supports,
cable conduits, piping, wooden structures, beams, purlins

Thread size M6 M6 M8 M8 M10 M10 M12 M12 M16 M16 M20 M20

Effective
hef [mm] 30 40 35 44 42 48 50 65 64 82 78 100
anchorage depth
Non-cracked concrete
Tensile C20/25 Nrec [kN] 2.9 4.1 5.0 5.7 6.5 7.6 8.5 12.6 12.3 17.9 16.6 24.0
C50/60 Nrec [kN] 4.1 4.1 7.3 7.3 10.1 11.8 13.2 16.7 19.1 27.7 25.7 37.3
Shear ≥ C20/25 Vrec [kN] 2.9 2.9 5.0 6.3 6.5 8.0 8.5 14.3 24.6 25.1 33.1 37.1
1)
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.
Installation:

33
W-FA/S, W-FA/F

Min. drill
Article description Art. No. Drill dia. Anchor Fixture Thread Wrench PU
hole depth
Length thickness Size size
for through
fastening
do h2 l tfix/tfix,red ØxlG SW
mm mm mm mm mm Qty.

W-FA/S M6-5/40 5932 006 040 6 35 40 5 M6 x 16 10 100


W-FA/S M6-10-20/67 5932 006 067 6 62 67 10 / 20 M6 x 30 10 100
W-FA/S M6-25-35/82 5932 006 082 6 77 82 25 / 35 M6 x 35 10 100
W-FA/S M6-40-50/97 5932 006 097 6 92 97 40 / 50 M6 x 35 10 100
W-FA/S M8-5/50 5932 008 050 8 45 50 5 M8 x 22 13 100
W-FA/S M8-10-19/75 5932 008 075 8 70 75 10 / 19 M8 x 40 13 100
W-FA/S M8-15-24/80 5932 008 080 8 75 80 15 / 24 M8 x 45 13 100
W-FA/S M8-25-34/90 5932 008 090 8 85 90 25 / 34 M8 x 55 13 100
W-FA/S M8-30-39/95 5932 008 095 8 90 95 30 / 39 M8 x 60 13 100
W-FA/S M8-45-54/110 5932 008 110 8 105 110 45 / 54 M8 x 75 13 100
W-FA/S M8-55-64/120 5932 008 120 8 115 120 55 / 64 M8 x 85 13 100
W-FA/S M10-10/60 5932 010 060 10 55 60 10 M10 x 25 17 50
W-FA/S M10-10-16/85 5932 010 085 10 80 85 10 / 16 M10 x 40 17 50
W-FA/S M10-15-21/90 5932 010 090 10 85 90 15 / 21 M10 x 45 17 50
W-FA/S M10-20-26/95 5932 010 095 10 90 95 20 / 26 M10 x 50 17 50
W-FA/S M10-30-36/105 5932 010 105 10 100 105 30 / 36 M10 x 60 17 50
W-FA/S M10-45-51/120 5932 010 120 10 115 120 45 / 51 M10 x 75 17 50
W-FA/S M10-70-76/145 5932 010 145 10 140 145 70 / 76 M10 x 80 17 50
W-FA/S M10-100-106/175 5932 010 175 10 170 175 100 / 106 M10 x 80 17 50
W-FA/S M10-140-146/215 5932 010 215 10 210 215 140 / 146 M10 x 80 17 25
W-FA/S M12-5/75 5932 012 075 12 70 75 5 M12 x 30 19 25
W-FA/S M12-10-25/105 5932 012 105 12 100 105 10 / 25 M12 x 60 19 25
W-FA/S M12-15-30/110 5932 012 110 12 105 110 15 / 30 M12 x 65 19 25
W-FA/S M12-20-35/115 5932 012 115 12 110 115 20 / 35 M12 x 70 19 25
W-FA/S M12-30-45/125 5932 012 125 12 120 125 30 / 45 M12 x 80 19 25
W-FA/S M12-50-65/145 5932 012 145 12 140 145 50 / 65 M12 x 100 19 25
W-FA/S M12-65-80/160 5932 012 160 12 155 160 65 / 80 M12 x 100 19 25
W-FA/S M12-85-100/180 5932 012 180 12 175 180 85 / 100 M12 x 100 19 25
W-FA/S M12-105-120/200 5932 012 200 12 195 200 105 / 120 M12 x 100 19 25
W-FA/S M12-125-140/220 5932 012 220 12 215 220 125 / 140 M12 x 80 19 25
W-FA/S M12-145-160/240 5932 012 240 12 235 240 145 / 160 M12 x 80 19 20
W-FA/S M12-160-175/255 5932 012 255 12 250 255 160 / 175 M12 x 80 19 20
W-FA/S M16-13/115 5932 016 115 16 110 115 13 M16 x 60 24 20
W-FA/S M16-10-28/130 5932 016 130 16 125 130 10 / 28 M16 x 70 24 20
W-FA/S M16-30-48/150 5932 016 150 16 145 150 30 / 48 M16 x 90 24 20
W-FA/S M16-60-78/180 5932 016 180 16 175 180 60 / 78 M16 x 110 24 20
W-FA/S M16-80-98/200 5932 016 200 16 195 200 80 / 98 M16 x 110 24 10
W-FA/S M16-100-118/220 5932 016 220 16 215 220 100 / 118 M16 x 80 24 10
W-FA/S M16-130-148/250 5932 016 250 16 245 250 130 / 148 M16 x 80 24 10
W-FA/S M16-165-183/285 5932 016 285 16 280 285 165 / 183 M16 x 80 24 10
W-FA/S M16-200-218/320 5932 016 320 16 315 320 200 / 218 M16 x 80 24 10
W-FA/S M16-220-238/340 5932 016 340 16 335 340 220 / 238 M16 x 80 24 10
W-FA/S M20-5-27/150 5932 020 150 20 145 150 5/27 M20 x 70 30 10
W-FA/S M20-35-57/180 5932 020 180 20 175 180 35/57 M20 x 70 30 10
W-FA/S M20-60-82/205 5932 020 205 20 200 205 60/82 M20 x 70 30 10
W-FA/S M20-95-117/240 5932 020 240 20 235 240 95/117 M20 x 70 30 10

34
W-FA/S, W-FA/F

Article description Min. drill


Art. No. Drill dia. hole depth Anchor Fixture Thread Wrench PU
for through Length thickness Size size
fastening
do h2 l tfix/tfix,red ØxlG SW
mm mm mm mm mm Qty.
W-FA/F M6-5/40 5932 906 040 6 35 40 5 M6 x 16 10 100
W-FA/F M8-15-24/80 5932 908 080 8 75 80 15 / 24 M8 x 45 13 100
W-FA/F M8-30-39/95 5932 908 095 8 90 95 30 / 39 M8 x 60 13 100
W-FA/F M8-55-64/120 5932 908 120 8 115 120 55 / 64 M8 x 85 13 100
W-FA/F M10-15-21/90 5932 910 090 10 85 90 15 / 21 M10 x 45 17 50
W-FA/F M10-30-36/105 5932 910 105 10 100 105 30 / 36 M10 x 60 17 50
W-FA/F M10-45-51/120 5932 910 120 10 115 120 45 / 51 M10 x 75 17 50
W-FA/F M12-15-30/110 5932 912 110 12 105 110 15 / 30 M12 x 65 19 25
W-FA/F M12-30-45/125 5932 912 125 12 120 125 30 / 45 M12 x 80 19 25
W-FA/F M12-50-65/145 5932 912 145 12 140 145 50 / 65 M12 x 100 19 25
W-FA/F M12-85-100/180 5932 912 180 12 175 180 85 / 100 M12 x 100 19 25
W-FA/F M16-30-48/150 5932 916 150 16 145 150 30 / 48 M16 x 90 24 20

35
W-FA/A4, W-FA/HCR
FIXANCHOR W-FA/A4, W-FA/HCR Approved for:
Concrete C20/25 to C50/60
W-FA/A4

Benefits:
• With a few blows the anchor is easy and fast to
install.
• The long thread allows levelling of unevenness and
can be used to assemble stand-off fixations.
W-FA/HCR • Two approved anchorage depth broaden the
application spectrum.
• Its approval guarantees safe function even under
highest load requirements.

Machine Setting Tool


Art. No. 0904 908 016

Applications: Approvals and Certificates:

Technical Data:
Head configuration Externally threaded
Environmental conditions Indoor, outdoor
Material composition Steel, galvanized
Type of fastening Through fastening
Non-cracked
Suitable for concrete
Cracked with
redundant fastening

Metal structures, metal profiles, brackets, foot plates, supports,


cable conduits, piping, wooden structures, beams, purlins

Thread size M6 M6 M8 M8 M10 M10 M12 M12 M16 M16 M20 M20
Effective
hef [mm] 30 40 35 44 42 48 50 65 64 82 78 100
anchorage depth
Non-cracked concrete
Tensile C20/25 Nrec [kN] 2.9 3.6 4.3 5.7 5.7 7.6 8.5 11.9 12.3 17.2 16.6 24.0
C50/60 Nrec [kN] 4.4 4.8 6.6 8.6 8.9 11.8 13.2 18.5 19.1 26.7 25.7 37.3
Shear ≥ C20/25 Vrec [kN] 4.0 4.0 5.0 6.9 6.5 8.0 8.5 15.4 24.6 28.6 33.1 43.9
1)
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.
Installation:

36
W-FA/A4, W-FA/HCR

Art. No. Drill dia. Min. drill Anchor Fixture Thread Wrench PU
Article description hole depth Length thickness Size size
for through
fastening
do h2 l tfix/tfix,red ØxlG SW
mm mm mm mm mm Qty.

W-FA/A4 M6-5/40 0904 411 061 6 35 40 5 M6 x 16 10 100


W-FA/A4 M6-10-20/67 0904 411 065 6 62 67 10 / 20 M6 x 30 10 100
W-FA/A4 M6-25-35/82 0904 411 066 6 77 82 25 / 35 M6 x 35 10 100
W-FA/A4 M6-40-50/97 0904 411 067 6 92 97 40 / 50 M6 x 35 10 100
W-FA/A4 M8-10-19/75 0904 411 083 8 70 75 10 / 19 M8 x 40 13 100
W-FA/A4 M8-15-24/80 0904 411 084 8 75 80 15 / 24 M8 x 45 13 100
W-FA/A4 M8-30-39/95 0904 411 087 8 90 95 30 / 39 M8 x 60 13 100
W-FA/A4 M8-55-64/120 0904 411 089 8 115 120 55 / 64 M8 x 85 13 100
W-FA/A4 M10-10-16/85 0904 411 002 10 80 85 10 / 16 M10 x 40 17 50
W-FA/A4 M10-15-21/90 0904 411 003 10 85 90 15 / 21 M10 x 45 17 50
W-FA/A4 M10-20-26/95 0904 411 004 10 90 95 20 / 26 M10 x 50 17 50
W-FA/A4 M10-30-36/105 0904 411 005 10 100 105 30 / 36 M10 x 60 17 50
W-FA/A4 M10-45-51/120 0904 411 006 10 115 120 45 / 51 M10 x 75 17 50
W-FA/A4 M12-15-30/110 0904 411 204 12 105 110 15 / 30 M12 x 65 19 25
W-FA/A4 M12-30-45/125 0904 411 206 12 120 125 30 / 45 M12 x 80 19 25
W-FA/A4 M12-85-100/180 0904 411 209 12 175 180 85 / 100 M12 x 80 19 25
W-FA/A4 M12-105-120/200 0904 411 210 12 195 200 105 / 120 M12 x 80 19 25
W-FA/A4 M16-30-48/150 0904 411 604 16 145 150 30 / 46 M16 x 90 24 20
W-FA/A4 M16-100-118/220 0904 411 607 16 215 220 100 / 116 M16 x 80 24 10
W-FA/A4 M20-35-57/180 0904 412 002 20 175 180 35 / 57 M20 x 70 30 10

W-FA/HCR M6-10/57 On demand 6 52 57 – / 10 M6 x 20 10 100


W-FA/HCR M6-10-20/67 On demand 6 62 67 10 / 20 M6 x 20 10 100
W-FA/HCR M6-25-35/82 On demand 6 77 82 25 / 35 M6 x 20 10 100
W-FA/HCR M6-40-50/97 On demand 6 92 97 40 / 50 M6 x 20 10 100

37
W-ED/S
Approved for:
DROP-IN ANCHOR W-ED/S
Concrete C20/25 to C50/60

W-ED/S Benefits:
• Easy installation due to low drive-in energy
• Visual setting check and hand protection when
installing with markingspreading tool Can be loaded
immediately – no waiting time.
• Attachment can easily be demounted at any time.

W-ED/S-BND

Approvals and Certificates:

Applications:
Technical Data:
Head configuration Inner thread
Environmental conditions Indoor, dry conditions
Material composition Steel, galvanized
Type of fastening Pre fastening
Suitable for Non-cracked concrete
Cracked with
redundant fastening

Attaching threaded rods, metal structures, metal profiles, grids, cable conduits,
pipelines, mounting rails

Range of loading: C20/25


Size M5 M6 M8 M10 M12 M16 M20
hef [mm] 25 30 30 40 30 40 50 65 80
Non-cracked concrete
Nrec [kN] 1.4 3.3 2.8 3.6 3.3 5.1 7.1 10.5 14.3
Vrec [kN] 1.5 2.1 3.9 3.9 3.9 4.1 9.0 16.8 26.2

Installation:

38
W-ED/S

Art. No. Min. Min.


Article description Drill dia. Min. Anchor PU
internal internal
drill hole Length thread thread
depth length length
do h2 l Lsd,min Lth
mm mm mm mm Qty.
W-ED/S M5 x 25 0904 5 8 25 25 6 10 100
W-ED/S M6 x 30 0904 010 06 8 30 30 7 13 100
W-ED/S M8 x 30 0904 010 08 10 30 30 9 13 100
W-ED/S M8 x 40 0904 010 081 10 40 40 9 20 100
W-ED/S M10 x 40 0904 010 10 12 40 40 11 15 50
W-ED/S M12 x 50 0904 010 12 15 50 50 13 18 50
W-ED/S M16 x 65 0904 010 16 20 65 65 18 23 25
W-ED/S M20 x 80 0904 010 20 25 80 80 22 34 25

W-ED/S-BND M8 x 30 0904 040 08 10 30 30 9 13 100


W-ED/S-BND M8 x 40 0904 040 081 10 40 40 9 20 100
W-ED/S-BND M10 x 30 0904 040 101 12 30 30 10 12 50
W-ED/S-BND M10 x 40 0904 040 10 12 40 40 11 15 50
W-ED/S-BND M12 x 50 0904 040 12 15 50 50 13 18 50

Marking-spreading tool with Art. No. Suitable for PU


hand protection (visual setting Qty.
check)
0904 022 08 W-ED M8 x 30 1
0904 022 081 W-ED M8 x 40 1
0904 022 101 W-ED M10 x 30 1
0904 022 10 W-ED M10 x 40 1
0904 022 12 W-ED M12 x 50 1
0904 022 16 W-ED M16 x 65 1
0904 022 20 W-ED M20 x 85 1

Spreading tool (no 0904 05 W-ED M5 x 25 1


visual setting Qcheck) 0904 020 06 W-ED M6 x 30 1
0904 020 08 W-ED M8 x 30 1
0904 020 081 W-ED M8 x 40 1
0904 020 101 W-ED M10 x 30 1
0904 020 10 W-ED M10 x 40 1
0904 020 12 W-ED M12 x 50 1
0904 020 16 W-ED M16 x 65 1
0904 020 20 W-ED M20 x 85 1

39
W-ED/A4
DROP-IN ANCHOR W-ED/A4, W-ED/HCR Approved for:
Concrete C20/25 to C50/60

Benefits:
• Easy installation due to low drive-in energy.
• Visual setting check and hand protection when
installing with markingspreading tool Can be loaded
immediately – no waiting time.
• Attachment can easily be demounted at any time.

Approvals and Certificates:

Applications:

Technical Data:
Head configuration Inner thread
Environmental conditions
Indoor, outdoor

Material composition A4 stainless steel / HCR
highly corrosion-resistant steel
Type of fastening Pre fastening
Non-cracked
Suitable for concrete
Cracked with redundant
fastening

Attaching threaded rods, metal structures, metal


profiles, grids, cable conduits, pipelines, mounting
rails

Range of loading:
Size M6 M8 M10 M12 M16 M20
hef [mm] 30 30 40 40 50 65 80
Non-cracked concrete
Nrec [kN] 3.3 3.3 3.6 6.1 8.5 12.6 17.2
Vrec [kN] 3.2 4.6 6.0 11.9 19.2 30.7

Installation:

40
W-ED/A4
Art. No. Min. Min.
Article description Drill dia. Min. Anchor PU
internal internal
drill hole Length thread thread
depth length length
do h2 l Lsd,min Lth
mm mm mm mm Qty.
W-ED/A4 M6 x 30 0904 030 06 8 30 30 7 13 100
W-ED/A4 M8 x 30 0904 030 08 10 30 30 9 13 100
W-ED/A4 M8 x 40 0904 030 081 10 40 40 9 20 100
W-ED/A4 M10 x 40 0904 030 10 12 40 40 11 15 50
W-ED/A4 M12 x 50 0904 030 12 15 50 50 13 18 50
W-ED/A4 M16 x 65 0904 030 16 20 65 65 18 23 25
W-ED/A4 M20 x 80 on demand 25 80 80 22 34 25

Marking-spreading tool with Art. No. Suitable for PU


hand protection (visual setting
check)
0904 022 08 W-ED M8 x 30 1
0904 022 081 W-ED M8 x 40 1
0904 022 101 W-ED M10 x 30 1
0904 022 10 W-ED M10 x 40 1
0904 022 12 W-ED M12 x 50 1
0904 022 16 W-ED M16 x 65 1
0904 022 20 W-ED M20 x 85 1

Spreading tool (no 0904 05 W-ED M5 x 25 1


visual setting Qcheck) 0904 020 06 W-ED M6 x 30 1
0904 020 08 W-ED M8 x 30 1
0904 020 081 W-ED M8 x 40 1
0904 020 101 W-ED M10 x 30 1
0904 020 10 W-ED M10 x 40 1
0904 020 12 W-ED M12 x 50 1
0904 020 16 W-ED M16 x 65 1
0904 020 20 W-ED M20 x 85 1

41
W-VP
Bonded anchor/ Capsule system W-VP Approved for:
Concrete C20/25 to C50/60
W-VP
Benefits:
• The pre-portioned resin volume guarantees
always safe adhesion and thus avoids
W-VD-A/S application errors.
• The short curing time allows to proceed
speedily.
• The included setting tool allows always smooth
installations.
W-VD-A/F • The usability can easily be checked and thus
avoids application errors.
• The capsule can be used as long the resin flows
like honey while shaking it.

W-VD-A/A4
Approvals and Certificates:

Applications:
Technical Data:
Head configuration Externally threaded
Environmental conditions Indoor, outdoor
Material composition Steel, galvanized / A4 stainless
steel / HCR highly corrosion-
resistant steel

Type
of fastening Pre fastening


Suitable for Non-cracked concrete

Temperature Minimum Curing time  Minimum Curing time 


of Concrete in dry concrete in wet concrete
-5°C bis 4°C 5h 10 h
5°C bis 19°C 1h 2h
20°C bis 29°C 20 min 40 min
≥ 30°C 10 min 20 min
Metal structures, metal profiles, brackets, foot plates, beams. 1)
Capsule temperature must be at min. 5°C.

Thread size M8 M10 M12 M16 M20 M24


Effective anchorage depth hef, typ [mm] 80 90 110 125 170 210
Non-cracked concrete
Tensile C20/25 Nrec [kN] 8.7 13.5 19.7 29.9 48.3 71.6
Shear ≥ C20/25 Vrec [kN] 5.3 8.3 12.1 22.4 35.0 50.3
Installation:

42
W-VP

Article description Article No. Drill Diameter Drill hole depth Fits*
d0 [mm] h0 [mm] PU
W-VP M8 5915 908 080 10 80 W-VD-A M8 10
W-VP M10 5915 910 080 12 90 W-VD-A M10 10
W-VP M12 5915 912 095 14 110 W-VD-A M12 10
W-VP M16 5915 916 095 18 125 W-VD-A M16 10
W-VP M20 5915 920 175 22 170 W-VD-A M20 10
W-VP M24 5915 924 210 26 210 W-VD-A M24 5
*Threaded rods see page 42

Anchor characteristics: W-VP


Thread size M8 M10 M12 M16 M20 M24
Effective anchorage depth hef [mm] 80 90 110 125 170 210
Nominal drill hole diameter d0 [mm] 10 12 14 18 22 26
Drill depth h0 ≥ [mm] = hef
Diameter of steel brush db ≥ [mm] 11 13 16 20 24 28
Clearance-hole in fixture to be attached df [mm] 9 12 14 18 22 26
Wrench size SW [mm] 13 17 19 24 30 36
Required torque Tinst [Nm] 10 20 40 80 120 180
Min. thickness of concrete member hmin [mm] 110 120 140 160 220 260
Minimum spacing smin [mm] 40 45 55 65 85 105
Minimum edge distances cmin [mm] 40 45 55 65 85 105

43
WIT-PE 500
Approved for:
Injection system WIT-PE 500 Concrete C20/25 to C50/60, cracked

Benefits:
• The prolonged gelling/working time allows
convenient adjustment at higher temperature
and with large embedment depth.
• Most approvals guarantee the optimized load
385 ml 585 ml 1400 ml capacities for threaded rods and rebar.
Art.no.: Art.no.: Art.no.: • It is specially developed chemical composition
0903 480 001 0903 480 003 0903 480 002 that allows reliable installation in underwater
conditions and when filled in diamond core drill
holes.
• The low shrinkage of the mortar broadens
the application spectrum in addition for big
∅8 - ∅40 diameter fastener elements.

M8 - M39

Applications: Approvals and Certificates:

Technical Data:
Head configuration Extended threaded
Environmental conditions Indoor, outdoor
Material composition Steel, galvanized / A4
stainless steel
Type
of fastening Pre fastening
Cracked
Suitable for concrete
Suitable for fastening metal constructions, metal profiles, brackets, Non-cracked concrete
foot plates, supports, cable conduits, pipes, railings, machines, etc.

Temperature Gelling - working time Minimum Curing time  Minimum Curing time
of Concrete in dry concrete in wet concrete 
5°C to 9°C 60 min 72 h 142 h
10°C to 19°C 45 min 45 h 90 h
20°C to 29°C 30 min  10 h 20 h
30°C to 39°C 20 min  6 h 12 h
≥ 40°C 12 min  4 h 8h

Installation:

44
WIT-PE 500
Recommended loads
Thread size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Effective anchorage depth hef,typ [mm] 80 90 110 125 170 210 240 270 300 330 360
Non-cracked concrete
Tensile C20/25 Nrec [kN] 8.7 13.8 20.1 28.0 38.1 52.3 63.9 76.2 89.3 103.0 117.3
C50/60 Nrec [kN] 8.7 13.8 20.1 30.8 41.9 57.5 70.3 83.8 98.2 113.3 129.1
Shear ≥ C20/25 Vrec [kN] 5.3 8.3 12.1 22.4 35.0 50.3 65.6 80.1 99.1 116.7 139.4
Cracked concrete
Tensile C20/25 Nrec [kN] 12.3 16.2 21.8 29.6 38.1 47.6
C50/60 Nrec [kN] 13.6 17.8 24.0 32.6 41.9 52.4
Shear ≥ C20/25 Vrec [kN] 12.1 22.4 35.0 50.3 65.6 80.1
1)
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.

Anchor challenges

Thread size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
hef,min [mm] 60 60 70 80 90 96 108 120 132 144 156
Effective anchorage depth
hef,max [mm] 96 120 144 192 240 288 324 360 396 432 468
Nominal drill hole diameter d0 [mm] 10 12 14 18 24 28 32 35 37 42 46
Drill depth h0 / h1 [mm] = hef
Clearance-hole in fixture
df [mm] 9 12 14 18 22 26 30 33 36 39 42
to be attached
Wrench size SW [mm] 13 17 19 24 30 36 41 46 50 55 60
Required torque Tinst [Nm] 10 20 40 80 120 160 180 200 350 500 700
Min. thickness of
hmin [mm] = hef + 30mm ≥ 100mm = hef + 2d0
concrete member
Minimum spacing smin [mm] 40 50 60 80 100 120 135 150 165 180 195
Minimum edge distances cmin [mm] 40 50 60 80 100 120 135 150 165 180 195
df

Dispensing Gun
d0

Art. No. : 1891 003103

45
WIT-PE 500
Recommended loads
Rebar size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø40

Effective anchorage depth hef,typ [mm] 80 90 110 125 125 170 210 270 300 360
Non-cracked concrete
Tensile C20/25 Nrec [kN] 11.2 15.7 21.4 28.0 28.0 38.1 52.3 76.2 89.3 117.3
C50/60 Nrec [kN] 12.3 17.3 23.5 30.8 30.8 41.9 57.5 83.8 98.2 129.1
Shear ≥ C20/25 Vrec [kN] 6.6 10.3 14.8 20.2 26.3 41.1 64.3 80.6 105.3 164.6
Cracked concrete
Tensile C20/25 Nrec [kN] 12.3 15.3 16.2 21.8 29.6 42.8 56.4
C50/60 Nrec [kN] 13.6 16.8 17.8 24.0 32.6 47.1 62.1
Shear ≥ C20/25 Vrec [kN] 14.8 20.2 26.3 41.1 64.3 80.6 105.3
1)
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.

Anchor challenges
Rebar size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø40

hef,min [mm] 60 60 70 75 80 90 100 112 128 160


Effective anchorage depth
hef,max [mm] 96 120 144 168 192 240 300 336 384 480
Nominal drill hole diameter d0 [mm] 12 14 16 18 20 24 32 35 40 50
Drill depth h0 / h1 [mm] = hef
Min. thickness of
hmin [mm] = hef + 30mm ≥ 100mm = hef + 2d0
concrete member
Minimum spacing smin [mm] 40 50 60 70 80 100 125 140 160 200
Minimum edge distances cmin [mm] 40 50 60 70 80 100 125 140 160 200

hmin
h0
hef
d0

46
WIT-VM 250
Injection system WIT-VM 250 Approved for:
Concrete C20 / 25 to C50/60, cracked

Benefits:
• Styrene-free, quick-curing high-performance
vinylester mortar allows the anchorage to be
finished in a short period of time.
• Most approvals guarantees optimized load
capacities for threaded rods and rebar.
• Universal fixing system for a broad range of
420 ml applications on building sites.
Art. No. : 0903 450 205 • The special chemical composition allows
working in high corrosion areas.

Approvals and Certificates:

∅8 - ∅32

M8 - M30

Applications:
Technical Data:
Head configuration Extended threaded
Environmental conditions Indoor, outdoor
Material composition Steel, galvanized / A4
stainless steel
Type
of fastening Pre fastening
Cracked
Suitable for concrete
Non-cracked concrete
Securing wooden structures, metal structures, metal profiles,
brackets, screens, plumbing objects,, cable conduits

Temperature Gelling - working time Minimum Curing time  Minimum Curing time
of Concrete in dry concrete in wet concrete 
-10°C bis -4°C1) 90 min 24 h 48 h
-5°C bis -1°C 90 min 14 h 28 h
0°C bis 4°C 45 min 7h 14 h
5°C bis 10°C 25 min 2h 4h
10°C bis 19°C 15 min 80 min 160 min
20°C bis 29°C 6 min 45 min 90 min
30°C bis 34°C 4 min 25 min 50 min
35°C bis 39°C 4 min 20 min 40 min
≥ 40°C 1.5 min 15 min 30 min
1)
Cartridge temperature must be at min. 15°C
Installation:

47
WIT-VM 250

Recommended loads
Thread size M8 M10 M12 M16 M20 M24 M27 M30
Effective anchorage depth hef,typ [mm] 80 90 110 125 170 210 240 270
Non-cracked concrete
Tensile C20/25 Nrec [kN] 8.7 13.5 19.7 28.0 44.4 61.0 74.5 88.9
C50/60 Nrec [kN] 8.7 13.8 20.1 30.8 48.9 67.1 82.0 97.8
Shear ≥ C20/25 Vrec [kN] 5.3 8.3 12.1 22.4 35.0 50.3 65.6 80.1
Cracked concrete
Tensile C20/25 Nrec [kN] 9.1 13.7 23.3 34.6 52.5 63.5
C50/60 Nrec [kN] 10.0 15.1 25.6 38.0 57.8 69.9
Shear ≥ C20/25 Vrec [kN] 12.1 22.4 35.0 50.3 65.6 80.1
1)
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.

Anchor characteristics
Thread size M8 M10 M12 M16 M20 M24 M27 M30
hef,min [mm] 60 60 70 80 90 96 108 120
Effective anchorage depth
hef,max [mm] 160 200 240 320 400 480 540 600
Nominal drill hole diameter d0 [mm] 10 12 14 18 24 28 32 35
Drill depth h0 / h1 [mm] = hef
Diameter of steel brush db ≥ [mm] 12 14 16 20 26 30 34 37
Clearance-hole in fixture
df [mm] 9 12 14 18 22 26 30 33
to be attached
Wrench size SW [mm] 13 17 19 24 30 36 41 46
Required torque Tinst [Nm] 10 20 40 80 120 160 180 200
Min. thickness of concrete member hmin [mm] = hef +30mm ≥ 100mm = hef + 2d0
Minimum spacing smin [mm] 40 50 60 80 100 120 135 150
Minimum edge distances cmin [mm] 40 50 60 80 100 120 135 150

Dispensing Gun
Art. No. : 1891 003003

48
WIT-VM 250

Recommended loads
Rebar size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32
Effective anchorage depth hef,typ [mm] 80 90 110 125 125 170 210 270 300
Non-cracked concrete
Tensile C20/25 Nrec [kN] 9.6 13.5 19.7 28.0 28.0 44.4 61.0 88.9 101.7
C50/60 Nrec [kN] 10.5 14.8 21.7 30.8 30.8 48.9 67.1 97.8 111.9
Shear ≥ C20/25 Vrec [kN] 6.6 10.3 14.8 20.2 26.3 41.1 64.3 80.6 80.6
Cracked concrete
Tensile C20/25 Nrec [kN] 9.1 13.7 17.1 28.0 38.9 63.5 74.4
C50/60 Nrec [kN] 10.0 15.1 18.9 30.8 42.8 69.9 81.8
Shear ≥ C20/25 Vrec [kN] 14.8 20.2 26.3 41.1 64.3 80.6 80.6
1)
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.

Anchor characteristics
Rebar size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32
hef,min [mm] 60 60 70 75 80 90 100 112 128
Effective anchorage depth
hef,max [mm] 160 200 240 280 320 400 480 540 640
Nominal drill hole diameter d0 [mm] 12 14 16 18 20 24 32 35 40
Drill depth h0 / h1 [mm] = hef
Diameter of steel brush db ≥ [mm] 14 16 18 20 22 26 34 37 41.5
= hef +30mm
Min. thickness of concrete member hmin [mm] = hef + 2d0
≥ 100mm
Minimum spacing smin [mm] 40 50 60 70 80 100 125 140 160
Minimum edge distances cmin [mm] 40 50 60 70 80 100 125 140 160

hmin
h0
hef
d0

49
Cleaning accessories

Cleaning accessories
For diameter Length Nom. drill dia. Cleaning Extension Machine Blow-Out P. Qty.
[mm] d0 [mm] Brush Art. No. Mounting Pump
Art. No. Art. No. Art. No.
M8 170 10 1903 489 000
M10, Ø8 170 12 1903 489 001
M12, Ø10 200 14 1903 489 002
Ø12 200 16 1903 489 003
M16, Ø14 300 18 1903 489 004
Ø16 300 20 1903 489 005 1903 489 111 Hexagon: 0903 990 001 1
0905 499 101
M20, Ø20 300 24 1903 489 006
M24 300 28 1903 489 007 SDS plus:
M27, Ø25 300 32 1903 489 008 1903 489 101
M30, Ø28 300 35 1903 489 009
Ø32 300 40 1903 489 010
Ø40 300 50 1903 489 011

Art. no. 1903 489 00* Art. No. 0903 990 001
1903 489 111

50
THREADED RODS
W-VD-A/S

W-VD-A/A4

Article Description Art. No. Art. No. Anchor Drill Min. drill Fixture Thread Wrench PU
Lenght dia. hole thickness Size Size
depth
Zinc plated Stainless steel l d0 h0 tfix M SW
Steel grade (5.8) Steel grade (A4-70) mm mm mm mm Qty.
W-VD-A M8-20/110 5915 108 110 5915 208 110 110 20
W-VD-A M8-60/150 5915 108 150 5915 208 150 150 10 80 60 M8 13
M8 x 1000 5916 008 999 5916 108 999 1000 -
W-VD-A M10-15/115 5915 110 115 5915 210 115 115 15
W-VD-A M10-30/130 5915 110 130 5915 210 130 130 30
W-VD-A M10-65/165 5915 110 165 5915 210 165 165 12 90 65 M10 17
W-VD-A M10-90/190 5915 110 190 5915 210 190 190 90
M10 x 1000 5916 010 999 5916 110 999 1000 -
W-VD-A M12-10/135 5915 112 135 5915 212 135 135 10
W-VD-A M12-35/160 5915 112 160 5915 212 160 160 35
W-VD-A M12-85/210 5915 112 210 5915 212 210 210 14 110 85 M12 19 10
W-VD-A M12-125/250 5915 112 250 5915 212 250 250 125
W-VD-A M12-175/300 5915 112 300 5915 212 300 300 175
M12 x 1000 5916 012 999 5916 112 999 1000 -
W-VD-A M16-20/165 5915 116 165 5915 216 165 155 20
W-VD-A M16-45/190 5915 116 190 5915 216 190 190 45
W-VD-A M16-85/230 5915 116 230 5915 216 230 230 18 125 85 M16 24
W-VD-A M16-105/250 5915 116 250 5915 216 250 250 105
W-VD-A M16-155/300 5915 116 300 5915 216 300 300 155
M16 x 1000 5916 016 999 5916 116 999 1000 -
W-VD-A M20-20/220 5915 120 220 5915 220 220 220 20
W-VD-A M20-60/260 5915 120 260 5915 220 260 260 22/24 170 60 M20 30
W-VD-A M20-100/300 5915 120 300 5915 220 300 300 100
M20 x 1000 5916 020 999 5916 120 999 1000 -
W-VD-A M24-15/260 5915 124 260 5915 224 260 260 15
W-VD-A M24-55/300 5915 124 300 5915 224 300 300 26/28 210 55 M24 36 5
M24 x 1000 5916 024 999 5916 124 999 1000 -

51
W-FRA 10
FRAME FIXING W-FRA 10

W-FRA 10 with countersunk screw

Benefits:
•Can be loaded immediately – no waiting time
•Very strong twist lock
W-FRA H 10 with hexagon screw and pressed-on washer •Universal frame-fixing anchor (concrete, masonry of
perforated and solid brick, aerated concrete)
•The anchor sleeve and special screw are
pre-assembled. Reduces installation efforts.

Applications: Approvals and Certificates:

Technical Data:
Hexagon, Countersunk
Head configuration
and Pan Head
Environmental conditions Indoor, Outdoor
Steel, galvanized / A4
Material composition
stainless steel
Through fastening
Type of fastening

Suitable for Multiple attachment of
non-structural systems in
concrete and masonry

The attachment of facade, ceiling, or roof substructures (made of wood


or steel), wood beams, wood laths, metal brackets, metal rails, suspend-
ed ceilings, cable routes, angle brackets, profiles, wall-mounted cabinets,
shelf units

Installation: Setting Instruction I Setting Instruction II

52
W-FRA 10

Load characteristics for masonry and concrete:


Substrate Description Density Standard Characteristics
pull-out
(kg/dm3)
resistance (kN)

Concrete C12/15 ≥ 1,8 EN 206-1 3,0*

Concrete ≥ C20/25 ≥ 2,3 EN 206-1 4,0*

Clay brick Mz ≥ 1,7 EN 771-1 3,5

Clay brick Mz ≥ 2,0 EN 771-1 3,5

Calcium silicate brick KS-NF-20-2.0-DIN106 ≥ 2,0 EN 771-2 3,5

Calcium silicate hollow block KSL-R(P)-8-DF-DIN106 ≥ 1,6 EN 771-2 2,5

Vertical perforated porous block Porotherm 25 P+W ≥ 0,8 EN 771-1 1,2

Vertical perforated ceramic block MAX 250 ≥ 0,8 EN 771-1 0,9

Perforated ceramic brick Hlz12 ≥ 1,2 EN 771-1 2,0


VBL 2 ≥ 0,8 EN 771-2 2,0

HBL 2 ≥ 0,8 EN 771-2 2,0

Autoclaved aerated concrete AAC2 ≥ 0,35 EN 771-4 0,6

Autoclaved aerated concrete AAC7 ≥ 0,65 EN 771-4 1,5

53
W-FRA 10
Fixture
Article Description Art. No. Art. No. Anchor
thickness for
Drive Wrench Drill Drill PU
length Size hole dia. hole depth
hnom=70mm
Zinc plated Stainless steel l tfix SW d0
A4 mm mm mm mm Qty.
0912 910 401 0912 910 501 80 10
Frame fixing W-FRA 10 0912 910 402 0912 910 502 100
with countersunk screw
30
0912 910 403 0912 910 503 120 50
0912 910 404 0912 910 504 140 70
0912 910 405 - 160 90
TX© 40 10 80 50
0912 910 406 - 180 110
0912 910 407 - 200 130
0912 910 408 - 230 160
0912 910 409 - 260 190
0912 910 410 - 300 230

0912 910 601 0912 910 701 80 10 50 (A4:25)


0912 910 602 0912 910 702 100 30 50 (A4:25)
Frame fixing W-FRA H 10
with hexagon screw + 0912 910 603 - 120 50 50
pressed-on washer 140 70
©
TX 40 13 10 80 50
0912 910 604 -
0912 910 605 - 160 90 50
0912 910 606 - 180 110 25
0912 910 607 - 200 130 25
0912 910 608 - 230 160 25
0912 910 609 260 190 25
0912 910 610 300 230 25

Substrate Minimum edge distance Min member thickness


c (mm) h (mm)
Concrete C20/25 60 100
Clay brick, 100 120
Calcium silicate brick 100 120
Hollow masonry 100 250
AAC 100 250

54
W-UR 8
PLASTIC FRAME-FIXING ANCHOR W-UR 8
PLASTIC FRAME-FIXING ANCHOR W-UR8 Multiple attachment of non
42.1 load-bearing systems: Con-
crete, solid and perforated bricks
W-UR 8 with countersunk screw
and aerated concrete
Benefits:
W-UR 8 with countersunk screw
Galvanized steel
W-UR F 8 with hexagon screw +
Stainless steel A4
• Can be loaded immediately – no waiting time
pressed-on
W-UR F 8 washer • Expanding in four directions - High loads
with hexagon screw + pressed-on washer
Galvanized steel
• Universal frame-fixing anchor (concrete, masonry of
W-UR F 8A4 with panhead screw
Stainless steel perforated and solid brick, aerated concrete)
W-UR F 8 with panhead screw
Galvanized steel
• The anchor sleeve and special screw are
Stainless steel A4 pre-assembled. Reduces installation efforts.
W-UR F 8connecting
W-UR F 8 with with thread
connecting
M6 + M8 thread
M6 + M8
Galvanized steel
Stainless steel A4

Evidence of Performance

Approvals Test Reports Good to know:


• Drill perforated and hollow blocks in rotating gear (without impact
European Technical Facade Fire mechanism).
Approval Covering • For anchoring in solid brick and solid sand-lime brick, we recommend that
Multiple attachment of non Resistance
you perform pull-out tests due to the dīerences in brick manufacturing.
load-bearing systems in W-UR 8, Concrete • Drilling dust is to be removed from the drill hole.
concrete and masonry W-UR F 8
W-UR (F) 8 and masonry
• Minimal insertion torque of the anchor screw ˈ “Slight” spreading of the anchor, almost no
turning of the anchor sleeve
Z-21.2-1838
• 2 setting depths (hnom = 50 + 70 mm): Concrete • C12/15; Solid brick • Mz 10 (• NF);

Applications: Approvals and Certificates:


Vertically perforated brick • HLz 8 (• 2DF); Solid sand-lime brick • KS 10 (•
NF); Perforated sand-lime brick • KS L 6 (• 2DF); Perforated sand-lime brick
• KS L 6 (• 12DF); Normal concrete solid bricks • Vbn 10 (• NF); Lightweight
concrete solid bricks • V 2 (• NF)
• Spreading in four directions ˈ High loads
• Improved power transmission: Even, continuous load distribution across the entire spreading
1. Applications area
• The anchor may be used with a European technical approval for the multiple attachment of • Universal frame-xing anchor (concrete, masonry of perforated and solid brick, aerated
non-load-bearing systems (e.g. facade, suspended ceiling, etc.) concrete)
• W-UR, W-UR F may be anchored in the following anchoring bases: • The knock-in lock prevents premature spreading of the anchor during installation
normal concrete • The anchor sleeve and special screw are pre-mounted ˈ Less mounting ēort
masonry walls (solid bricks, solid sand-lime bricks, vertically perforated bricks, perforated • Anchor type W-UR F means an additional washer is not required and prevents contact corro-
sand-lime bricks, hollow blocks made of lightweight concrete, solid stones and solid blocks of sion
lightweight concrete, masonry stones made of concrete) • Improved transmission of force in solid and hollow construction materials
Brick ceilings, hollow pre-stressed concrete panels, reinforced concrete,
gypsum wall panels 3. Properties
• Installation temperatures: • Anchoring via friction engaging between anchor sleeve and anchor surface
Temperature in anchoring base: • –40°C • W-UR 8, W-UR F 8 (galvanized steel, stainless steel):
Temperature of anchor sleeve: • 0°C General construction permit Z-21.2-1838
• The stainless-steel screw may be used outdoors and in industrial atmospheres and near the sea • W-UR 8 and W-UR F 8 (galvanized steel, stainless steel):
• The galvanized screw may be used outdoors or in damp rooms (careful installation) if the area European Technical Approval ETA-08/0190
near the screw head is protected against moisture or driving rain so that penetration of moi-
sture into the anchor shaft is not possible (suitable paint).
• Suitable for the attachment of facade, ceiling, or roof substructures (made of wood or steel),
• The anchor sleeve is made of high-quality polyamide
• Fire resistance W-UR 8: Technical Data:
Concrete: Tensile and transverse load, R30, R60, R90, R120
wood beams, wood laths, metal brackets, metal rails, suspended ceilings, cable routes, angle
brackets, proles, wall-mounted cabinets, shelf units, etc.
(based on Technical Report TR 020)
Masonry: Tensile load: F30 (solid sand-lime bricks, solid bricks, perforated sand-lime
Head configuration Hexagon, Countersunk
2. Advantages
• Through-bolt mounting
bricks)
Transverse load: F30, F60, F90, F120 (vertically perforated bricks, perforated
sand-lime bricks, solid bricks, aerated
and Pan Head
• Can be loaded immediately – no waiting time concrete)
Environmental conditions Indoor, Outdoor
Setting Instructions I Setting Instructions II
Material composition Steel, galvanized / A4
stainless steel
Type of fastening
Through fastening
MWF - 11/10 - 10843 - ©


Drill hole Clean drilled
hole
Set anchor and
screw
Screw in screw Screw in screw
until ush
Drill hole Clean drilled
hole
Set anchor and
screw
Screw in screw Screw in screw
until ush

Suitable for Non-cracked concrete

The attachment of facade, ceiling, or roof substructures (made of wood


or steel), wood beams, wood laths, metal brackets, metal rails, sus-
pended ceilings, cable routes, angle brackets, profiles, wall-mounted
cabinets, shelf units

Installation: Setting Instruction I Setting Instruction II

55
W-UR 8

Anchor characteristics for concrete and masonry


Size W-UR 8
Drill dia. d0 [mm] 8
Drill hole depth h1 ≥ [mm] 60 80
Setting depth of anchor sleeve hnom [mm] 50 70
Through - hole in attachment part df ≤ [mm] 8.5

Load characteristics for concrete


Tensile load C12/15 Nperm [kN] 1.2 1.6
C16/20 Nperm [kN] 1.8 1.4
Shear load Zinc Vperm [kN] 3.37
A4
C12/15 Vperm [kN] 3.16

Load characteristics for masonry


Format Density [kg/dm3] Compressive strenghts [kg/dm3] Fperm [kN]
Lightweight concrete hollow block HBL 2 - 0.11
≥ 498 x 240 x 238 ≥ 0.7 4 - 0.26
EN 771-3 6 - 0.34
2 - 0.17
Lightweight concrete hollow block Liapor-Super K ≥ 498 x 240 x 238 ≥ 0.8
4 - 0.34
Aerated concrete AAC 2 - 0.14
7 - 0.85

Anchor Fixture Wrench


Article Description Art. No. Art. No. thickness for
Drive PU
length Size
hnom=50mm hnom=70mm
Zinc plated Stainless steel l tfix tfix SW
A4 mm mm mm Qty.
0912 808 402 0912 808 502 60 10 -
Frame fixing W-UR 8
with countersunk screw 0912 808 403 0912 808 503 80 30 10 AW© 30
0912 808 404 on demand 100 50 30
0912 808 405 on demand 120 70 50
0912 808 406 - 140 90 70
0912 808 407 - 160 110 90
0912 808 602 0912 808 702 60 10 -
Frame fixing W-UR F 8
with hexagon screw + 0912 808 603 0912 808 703 80 30 10 AW© 25 10
pressed-on washer 0912 808 604 on demand 100 50 30
0912 808 605 on demand 120 70 50
Frame fixing W-UR F 8 0912 808 802 0912 808 902 60 10 - 50
with pan head screw AW© 30
0912 808 803 0912 808 903 80 30 10
Frame fixing W-UR F 8 0912 808 202 0912 808 302 60 10 -
with M6 stud screw
10
0912 808 203 0912 808 303 80 30 10
Frame fixing W-UR F 8 0912 808 252 - 60 10 -
with M8 stud screw
0912 808 253 - 10
80 30 10

56
W-UR 10
PLASTIC FRAME-FIXING ANCHOR W-UR 10
42.2
PLASTIC FRAME-FIXING ANCHOR W- 10
Multiple fastenings of non-load-
W-UR 10 with countersunk screw bearing systems:
Concrete, solid and perforated brick and
Benefits:
aerated concrete
•Can be loaded immediately – no waiting time
•Very
W-UR strong
10 with twist lock
countersunk screw

W-UR F 10 with hexagon screw •Universal


Galvanized steelframe-fixing anchor (concrete, masonry of
Stainless steel A4 and solid brick, aerated concrete)
perforated
and pressed-on washer
•The anchor sleeve and special screw are
W-UR F 10 with hexagon screw and
pre-assembled. Reduces installation efforts.
pressed-on washer
Galvanized steel
Stainless steel A4

Applications: Approvals and Certificates:


Proof of performance

Approvals Test reports Good to know:


• Drill perforated and hollow blocks in rotating gear (without impact
European Facade Fire mechanism).
Technical Approval covering • For anchoring in solid brick and solid sand-lime brick, we recommend
Multiple attachment of resistance
that you perform pull-out tests due to the dī erences in brick
non-load-bearing systems W-UR 10, Concrete and manufacturing.
in concrete and masonry W-UR F 10 • Drilling dust must be removed from the drill hole.
masonry
W-UR (F) 10 Technical Data:
2. Advantages
• Through-bolt mounting Hexagon, Countersunk
Z-21.2-1838 Headtimes configuration
and Pan Head
• Can be loaded immediately – no waiting
• Minimum insertion torque of the anchor screw ˈ "Slight" spreading of the anchor, almost no
turning of the anchor sleeve Environmental conditions Indoor, Outdoor
• Very strong twist lock

• Spreading in four directions ˈ HighMaterial
load-bearingcomposition
capacities
Steel, galvanized / A4
• Improved power transmission: Even, stainless
continuous load distribution across the entire steel
1. Applications spreading area
Through fastening
• With European Technical Approval, the anchor may be used for multiple attachment of Typemasonry
• Universal frame-xing anchor (concrete, of fastening
made of perforated and solid stone,
non-load-bearing systems (e.g. facade, suspended ceiling etc.) aerated concrete)
• W-UR, W-UR F may be anchored in the following anchoring bases: • The knock-in lock prevents premature spreading of the anchor during installationMultiple attachment of
Standard concrete • The anchor sleeve and special screwSuitable for ˈ Less mounting ēort
are pre-mounted
Masonry walls (solid brick, solid sand-lime brick, vertically-perforated brick, perforated
• Anchor type W-UR F means an additional U-washer is not required and preventsnon-structural
contact systems in
sand-lime brick, hollow blocks made of lightweight concrete, solid stone and solid blocks corrosion
made of lightweight concrete, masonry stone made of concrete) and hollow construction
• Improved transmission of force in solid concrete and masonry
Aerated concrete
• Installation temperatures:
Temperature of anchoring base: • –20°C 3. Properties
Temperature of anchor sleeve: • 0°C • Anchoring via friction engaging between anchor sleeve and anchor surface
• The stainless-steel screw may be used outdoors and in industrial atmospheres and near the • W-UR 10 and W-UR F 10 (galvanized steel, stainless steel):
sea General construction permit Z-21.2-1838
• The galvanized screw may be used outdoors or in damp rooms (careful installation) if the • W-UR 10 and W-UR F 10 (galvanized steel, stainless steel):
area near the screw head is protected against moisture so that penetration of moisture into European Technical Approval ETA-08/0190
the anchor shaft is not possible (suitable paint) • The anchor sleeve is made of high-quality polyamide
The attachment of facade, ceiling, or roof substructures (made of wood
• Suitable for the attachment of facade, ceiling and roof substructures (made of wood or • Fire resistance of W-UR 10:
Concrete: Tensile and transverse loads, R30, R60, R90, R120
steel), wood beams, wood lath, metal brackets, metal rails, false ceilings, cable routes,
or steel), wood beams, wood laths, metal brackets, metal rails, suspend-
angle brackets, proles, hanging cabinets, shelves etc. (in accordance with Technical Report TR 020)
MasonryTensile load: F30 (solid sand-lime brick, solid brick, perforated sand-lime brick)
ed ceilings, cable routes, angle brackets, profiles, wall-mounted cabinets, Transverse load: F30, F60, F90, F120 (vertically-perforated brick, perforated
sand-lime brick, solid brick,aerated
shelf units concrete)
Setting Instructions I Setting Instructions II
MWF - 09/10 - 12406 - ©

Drill hole Clean drill hole Set anchor and Screw in the Screw in screw Drill hole Clean drill hole Set anchor and Screw in the Screw in screw
screw screw until ush screw screw until ush

Installation: Setting Instruction I Setting Instruction II

57
W-UR 10

Anchor characteristics for concrete and masonry


Size W-UR 10
Drill dia. d0 [mm] 10
Drill hole depth h1 ≥ [mm] 80
Setting depth of anchor sleeve hnom [mm] 70
Through - hole in attachment part df ≤ [mm] 10.5

Load characteristics for concrete


Tensile load C12/15 Nperm [kN] 1.0
C16/20 Nperm [kN] 1.6
Shear load Zinc Vperm [kN] 5.37
A4
C12/15 Vperm [kN] 4.99

Load characteristics for masonry


Format Density [kg/dm3] Compressive strenghts [kg/dm3] Fperm [kN]
Lightweight concrete hollow block HBL 2 0.09
≥ 498 x 240 x 238 ≥ 0.7 4 0.17
EN 771-3 6 0.26
2 0.17
Lightweight concrete hollow block Liapor-Super K ≥ 498 x 240 x 238 ≥ 0.8
4 0.34
Aerated concrete AAC 2 0.21
7 0.88

Fixture
Article Description Art. No. Art. No. Anchor
thickness for
Drive Wrench PU
length Size
hnom=70mm
Zinc plated Stainless steel l tfix SW
A4 mm mm Qty.
0912 810 401 0912 810 501 80 10
Frame fixing W-UR 10 0912 810 402 0912 810 502 100
with countersunk screw
30
0912 810 403 0912 810 503 115 45
0912 810 404 0912 810 504 135 65
0912 810 405 0912 810 505 160 90 13
AW© 40 50
0912 810 406 0912 810 506 185 115
0912 810 407 0912 810 507 200 130
0912 810 408 - 230 160
0912 810 409 - 260 190
0912 810 410 - 290 220
0912 810 411 - 320 250
0912 810 601 0912 810 701 80 10
0912 810 602 0912 810 702 100 30
Frame fixing W-UR F 10
with hexagon screw + 0912 810 603 0912 810 703 115 45
pressed-on washer 135 AW© 40 13 40
0912 810 604 0912 810 704 65
(only zinc version)
0912 810 605 0912 810 705 160 90
0912 810 606 - 185 115
0912 810 607 - 200 130
0912 810 608 - 230 160

58
W-ZX ®
ZEBRA SHARK W-ZX® Benefits:
• Ensures knotting in all hollow spaces and spreading
in all solid materials.
• Patented anchor head causes knotting of the
anchor shaft when the screw is screwed-in.
• Low screw-in torque and high fixed torque
• The drive-in lock prevents early spreading during
through fastening.
Setting Tool • Fold-down dowel collar translates to suitability for
Art. No. : 0906 100 001 pre fastening and through fastening.
• The twist lock prevents turning in the drill hole.
• The ZEBRA Shark W-ZXR is suitable for all screw
types.

Applications:
Securing coat rails, curtain rails, Technical Data:
wall shelves, light hanging cup- Head configuration All
boards, picture frames, mirrors, Environmental conditions Indoor, Outdoor
Material composition Plastic
lamps, cable ducts, cable clamps,
Type of fastening Pre fastening
electrical switches, wash basins,
Suitable for concrete, solid brick, solid
hand towel rails, signs, motion de-
sand-lime brick, vertically
tectors, hanging baskets. perforated brick, perforated
sand-lime brick, aerated
concrete, gypsum
plasterboard, gypsum
fibrous panels

Fixing characteristics
Article description W-ZX 5 × 28 W-ZX 6 × 35 W-ZX 8 × 46 W-ZX 10 × 56 W-ZX 12 × 66 W-ZX 14 × 76
Art.No. 0906 205 28 0906 206 35 0906 208 46 0906 210 56 0906 212 66 0906 214 76
Drill dia. d0 mm. 5 6 8 10 12 14
Drill hole depth h1 ≥ mm. 40 50 60 75 80 90
Length fixing l mm. 28 35 46 56 66 76
Screw dia. ds mm. 3-4 4-5 4,5-6 6-8 8-10 10-12
Package Unit PU Qty. 200 200 200 100 50
Load characteristics
Concrete C20/C25 Frec kN 0.4 0.8 1.0 1.6 2.2 2.5
Solid bricks Mz12, KS12 Frec kN 0.3 0.5 0.7 1.4 1.7 1.7
Aerated concrete PB2, PP2 Frec kN 0.05 0.1 0.1 0.15 0.2 0.35

Screw length = Length fixing + screw dia. + fixture thickness (+plaster/insulation thickness)

Installation:

59
W-GB
AIRCRETE ANCHOR W-GB

Suitable for:
AAC, ACC, ALC

Benefits:
•W-GB is in particular developed for AAC, ACC and
ALC to provide highest load capacity.
•Fast installation

Applications:
Facade and roof constructions made Technical Data:
of wood and metal, windows, doors, Head configuration All
brackets, cable ducts, switches, Environmental conditions Indoor, outdoor
Material composition Plastic
lights, fuse boxes, cable clips, pipe Type of fastening Pre fastening
clamps, toilet and washbasin attach- Suitable for Aerated concrete PB2
ments, hanging cabinets, strips, rail-
ings

Fixing characteristics
Article description GB 10 x 55 GB 12 x 60 GB 14 x 75
Art.No. 0903 50 10 0903 50 12 0903 50 14
Drill dia. d0 mm. 10 12 14
Drill hole depth h1 ≥ mm. 65 70 85
Length fixing l mm. 55 60 75
Screw dia. ds mm. 4.5 - 6 7-8 10
Package Unit PU Qty. 25 25
25
Load characteristics
AAC 2 N/mm2 Frec kN 0.3 0.3 0.5
AAC 4 N/mm2 Frec kN 0.6 0.5 1.15
AAC 6 N/mm2 Frec kN - 0.8 -

Installation:

60
W-GS
W-GS GYPSUM
Gypsum PLASTERBOARD
Plasterboard ANCHORS
Fixing W-GS 73

Type Z
Benefits:
W-GS/Z diecast zinc
Diecast zinc • Less space required behind the board
(only 15 mm)
Type Z/L • For use without a setting tool with a
Diecast zinc, long battery-powered screwdriver and appropriate bit
W-GS/ZL diecast zinc large for the respective screw.
Type K • The new centering tip enables easy starting and
Plastic drilling into the board.
• Inexpensive, fast installation without pre-drilling.
W-GS/K plastic Product Range Case • Fast installation with a battery-powered
screwdriver.

Performance facts

Applications:
1. Applications Product Range Case
• For secondary attachments in gypsum plasterboards/brous panels Range of W-GS Gypsum Plasterboard Technical Data:
and light building boards Anchors
• For the attachment of components in conjunction with a wood or
Contents: Head configuration All
Anchors: 100 pcs. 14.5 x 33 mm plastic,
particle board screw (no drill tip, counter thread, ring thread) 100 pcs. 14.5 x 33 mm diecast zinc Environmental conditions Indoor, dry conditions
Screws: 200 pcs. 4.5 x 35 mm
• Can be used outside or in rooms subject to moisture in conjunction with + 1 pc. ZEBRA® Screwdriver Material composition diecast zinc /plastic
a stainless-steel screw Art. No. 0613 253 2 = 401 parts.
Art. No. 0964 903 250 Type of fastening Pre fastening
• We recommend using type Z/L for double-planked boards
• Recommended universal bit mount:
Suitable for Gypsum plasterboard
Bit MountFor
withattachments
quick-action chuckin– Art.
gypsum plasterboards/fibrous
No. 0614 176 711 •panels
The gypsum and light boards;
plasterboard anchor and the screw can be inserted with
Universal Mount – Art. No. 0614 176 708 the same bit
for use with wood and chipboard screw.
• The new centering tip enables easy starting and drilling into the board
2. Advantages • Inexpensive, fast installation without pre-drilling
• The patented drive enables setting of an anchor with a PZ bit, AW • Fast installation with a battery-powered screwdriver
bit or Torx bit, as the power transmission takes place via the hexagon • The component can be secured with wood or particle board screws
(Detail 1) (type Z + type Z/L = screw dia. of 4.5 mm/type K = screw dia. of 4.5 –
• The patented twist lock is triggered by screwing in a screw. When 5 mm)
unscrewing the screw, the gypsum plasterboard plug does not turn
back and remains in the anchoring base (Detail 2) 3. Properties
• Less space required behind the board (only 15 mm) • High plastic or diecast zinc quality
Fixing
• For use without a settingcharacteristics
tool with a battery-powered screwdriver and • Temperature-neutral from -40°C to +80°C
appropriate bit for the respective screw • Form-
W-GS ttingType
fastening
Z W-GS Type Z/L W-GS Type K
Article description
Art.No. 0903 2521 0903 2521 0903 2511
Setting instructions
Through - hole in fixture df≤ mm 6.5 6.5 6.5
Minimum bore thickness d≥ mm 9 9 9
Length fixing l mm 33 39 33
Screw dia. ds mm 4.5 4.5 4.5 - 5
Press anchor tips Screw in anchor Fit the component Detail 1: Detail 2:
into attachment
Package until
Unit flush
PUThe patented drive enables setting with
PZ bit, AW bitQty. 200
Patented twist lock
200
surface or Torx bit
200
Load characteristics
Gypsum plasterboard - 12.5 mm Nrec kN 0.1 0.1 0.1
Tension Gypsum plasterboard - 25 mm Nrec kN 0.1 0.12 0.1
Gypsum fibrous panels Nrec kN 0.12 0.12 -
Gypsum plasterboard - 12.5 mm Vrec kN 0.12 0.12 0.12
Shear Gypsum plasterboard - 25 mm Vrec kN 0.15 0.15 0.12
Gypsum fibrous panels Vrec kN 0.15 0.15 -

Installation:

61
YOUR RIGHT PARTNER
Please feel free to contact us using the details below - we would be more than happy to visit and demonstrate our
way of working, products we supply and service we provide.
Your friendly Würth Gulf Sales Consultant will visit when required by you, the customer at your convenience.

Wurth Gulf FZE


Plot # S61303, Jebel Ali South 6
Dubai, U.A.E - P.O.Box:17036
T: +9714 8809991
F: +971 4 8809255
E: wurthglf@emirates.net.ae
Website: www.wurth.ae
www.wuerth.com

DUBAI SHOWROOM SHARJAH SHOWROOM ABU DHABI SHOWROOM FUJAIRA

318th Almedan Road, Sharjah, U.A.E. Abu Dhabi, U.A.E. Fujairah, U.A.E
Industrial Area 4, Al Quoz, Tel : +971 6 5391919 Tel : +971 2 5544155 Email : fujpickshop1@wurthgulf.ae
Dubai, U.A.E. Fax : +971 6 5391917 Fax : +971 2 5544199
Email : dxbpickshop1@wurthgulf.ae Email : shjpickshop1@wurthgulf.ae Email : adpickshop1@wurthgulf.ae

BUSINESS PARTNERS

QATAR Iraq KUWAIT BAHRAIN


Email : info@wurthgulf-qatar.com Email: info@wurthgulf-iraq.com Email: info@wurthgulf-kuwait.com Email: info@wurthgulf-bahrain.com

Oman KSA
Email: info@wurthgulf-oman.com Email: info@wurthgulf-ksa.com

Potrebbero piacerti anche