Typical Problems
of Hardware Installation
www.huawei.com
The fibers are bended in a wrong way, which is very easy to make the
fibers broken. This problem is the most critical and familiar. According
to the installation standard, the bend radius must be at least 40mm.
Critical Problem about Fibers
Some cable
connectors
in all sites
are not
fastened,
which will
result in the
connectors
in bad
connect.
According to
the
installation
standard, all
connectors
of the cables
must be
fastened.
Problem about protection
The connector of
grounding cable of RRU
is not wrapped by Heat-
Shrink Tube, which will be
harmful to the RRU.
Problem about installation location
After installation
finished ,some sites
are not cleaned up.
Problem about Grounding Cable
Thank You
www.huawei.com
www.huawei.com
Nov, 2006
www.huawei.com
1. Label “ALM RRU*” are used for RRU alarm cable, not for E1
trunk cable. ALM=Alarm
Site 0036HU-----BBU label
1. Optical fiber (4 cords) for first sector must be tagged with Green color ring
2. Optical fiber (4 cords) for second sector must be tagged with Orange color ring
3. Optical fiber (4 cords) for third sector must be tagged with Blue color ring
Site 0036HU-----Optical fiber lay out
1. Optical fiber must be lay out smoothly, please leave enough length to make a
circle
Site 0036HU-----Optical fiber lay out