Sei sulla pagina 1di 6

ATN Series

DIN W48×H48mm, Universal Voltage Multi-Function Timer


Features
● Realization of wide range of power supply
:100-240VAC 50/60Hz, 24-240VDC universal,
24VAC 50/60Hz, 24VDC universal, 12VDC
● Various output operation (6 kinds modes)
● Multi time range (16 kinds of time range)
● Wide control time (0.05sec to 100hour)
● Easy setting of time, time range, output operation mode
● Easy to check output status by indicator

Please read “Safety Considerations” in operation


manual before using.

Ordering Information
AT 8 N
No mark 100-240VAC 50/60Hz, 24-240VDC
Power supply
1 12VDC
2 24VAC 50/60Hz, 24VDC
Time limit DPDT (2c) or instantaneous SPDT (1c)+Time limit SPDT (1c)
Time operation N
selectable by output operation mode
DN Time limit DPDT (2c)
EN Instantaneous SPDT (1c)+Time limit SPDT (1c)
Number of plug pins 8 8-pin plug type
11 11-pin plug type
Item
AT Analog Timer
※8-pin socket (PG-08, PS-08(N)) and 11-pin socket (PG-11, PS-11(N)) is sold separately.

Specifications
Model AT8N- AT11DN- AT11EN-
Function Multi Function Timer
※1
Control time setting range 0.05sec to 100hour
Power supply • 100-240VACᜠ 50/60Hz, 24-240VDCᜡ universal • 24VACᜠ 50/60Hz, 24VDCᜡ universal • 12VDCᜡ
Allowable voltage range 90 to 110% of rated voltage
• Max. 4.3VA (100-240VACᜠ), • Max. 3.5VA (100-240VACᜠ), • Max. 4.3VA (100-240VACᜠ),
Max. 2W (24-240VDCᜡ) Max. 1.5W (24-240VDCᜡ) Max. 2W (24-240VDCᜡ)
Power consumption • Max. 4.5VA (24VACᜠ), • Max. 4VA (24VACᜠ), • Max. 4.5VA (24VACᜠ),
Max. 2W (24VDCᜡ) Max. 1.5W (24VDCᜡ) Max. 2W (24VDCᜡ)
• Max. 1.5W (12VDCᜡ) • Max. 1W (12VDCᜡ) • Max. 1.5W (12VDCᜡ)
Return time Max. 100ms
Timing operation Power ON Start Signal ON Start
Min. input signal width - INHIBIT, START, RESET: Approx. 50ms
INHIBIT, START, RESET: [No-voltage input]
Input - - Short-circuit impedance: Max. 1kΩ, Residual voltage: Max. 0.5V,
Open-circuit impedance: Min. 100kΩ
Time limit DPDT (2c) or
Instantaneous SPDT (1c)+ Instantaneous SPDT (1c)+
Control Contact type Time limit DPDT (2c)
Time limit SPDT (1c) Time limit SPDT (1c)
output selectable by output operation mode
Contact capacity 250VACᜠ 5A resistive load
Relay Mechanical Min. 10,000,000 operations
life cycle Electrical Min. 100,000 operations (250VAC 5A resistive load)
Repeat error Max. ±0.2% ±10ms
SET error Max. ±5% ±50ms
Voltage error Max. ±0.5%
Temperature error Max. ±2%
Insulation resistance Over 100MΩ (at 500VDC megger)
※1: Refer to time specifications for control time setting range by model.

K-62
Multi Function Analog Timer
Specifications (A)
Photoelectric
Sensors
Model AT8N- AT11DN- AT11EN-
Dielectric strength 2,000VAC 50/60Hz for 1 minute (B)
Fiber
AT -1 Optic
Noise ±500V the square wave noise (pulse width 1µs) by noise simulator
AT -2 Sensors
immunity
AT ±2kV the square wave noise (pulse width 1µs) by noise simulator (C)
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz (for 1min) in each X, Y, Z direction for 1hour Door/Area
Vibration Sensors
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz (for 1min) in each X, Y, Z direction for 10min
Mechanical 300m/s2 (approx. 30G) in each X, Y, Z direction 3 times
Shock (D)
Malfunction 100m/s2 (approx. 10G) in each X, Y, Z direction 3 times Proximity
Sensors
Environ- Ambient temperature -10 to 55℃, storage: -25 to 65℃
ment Ambient humidity 35 to 85%RH, storage: 35 to 85%RH (E)
Pressure
Approval ᜢᜧ Sensors
Accessory Bracket
※2
Weight Approx. 134.12g (approx. 86.71g) Approx. 132.2g (approx. 85g) Approx. 134.7g (approx. 87.5g) (F)
Rotary
※2: The weight includes packaging. The weight in parenthesis is for unit only. Encoders
※Environment resistance is rated at no freezing or condensation.
(G)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/Sockets

Connections (H)
Temperature
AT8N Controllers

● When selecting [A], [F] ● When selecting [A1], [B], [F1], [I] (I)
SSRs / Power
output operation mode output operation mode Controllers

(J)
4 5 4 5 Counters

3 6 CONTACT OUT: 3 6 CONTACT OUT:


(K)
250VAC 5A 250VAC 5A Timers
2 7 RESISTIVE LOAD 2 7 RESISTIVE LOAD
1 8 1 8 (L)
(Time limit 1c) (Time limit 1c) (Instantaneous 1c) (Time limit 1c) Panel
Meters

※1 ※1
(M)
Tacho /
- + - + Speed / Pulse
Meters

(N)
※1: AC/DC voltage: 100-240VAC 50/60Hz, 24-240VDC Display
Units
: 24VAC 50/60Hz, 24VDC
DC voltage:12VDC
(O)
Sensor
Controllers

(P)

AT11DN AT11EN Switching


Mode Power
Supplies

RESET RESET (Q)


Stepper Motors
& Drivers
START START & Controllers

6 6 (R)
INHIBIT 5 7 INHIBIT 5 7 Graphic/
Logic
4 8 4 8 Panels

3 CONTACT OUT: 3 9 CONTACT OUT: (S)


9 Field
250VAC 5A 250VAC 5A Network
2 10 RESISTIVE LOAD 2 10 Devices
1 11 RESISTIVE LOAD
1 11
(T)
Software
(Time limit 1c) (Time limit 1c) (Instantaneous 1c) (Time limit 1c)

- + ※1 ※1
- +

※1: AC/DC voltage: 100-240VAC 50/60Hz, 24-240VDC


: 24VAC 50/60Hz, 24VDC
DC voltage:12VDC

K-63
ATN Series
Dimensions 64.5
15 50 (unit: mm)
48

44.8
※8-pin socket (PG-08, PS-08(N)) and 11-pin socket (PG-11, PS-11(N)) is sold separately.
Refer to the '(G)Connectors/Connector Cables/Sensor Distribution Boxes/Sockets'.

● Bracket ● Panel cut-out


48.6 20
45 5
Min. 65

16
36
44.9

45 +0.6
0

Min. 65
55 15 45+0.6
0

21
31

56

Unit Description
Operation/Power indicator
(Flashes for timer operation, Time limit output indicatior
Turns ON for timer stop)

Time range indication Output operation mode display part


AT8N
(A, A1, B, F, F1, I mode)
Time range setting switch
AT11DN/AT11EN
(A, F, F1, C, D, I mode)
Time unit indication
Output operation mode setting switch
(SEC, MIN, HOUR, 10H mode)

Time Specifications
Time range Time unit Time setting range Time range Time unit Time setting range
0.5 0.05 to 0.5sec 0.5 0.05 to 0.5hour
1 0.1 to 1sec 1 0.1 to 1hour
SEC HOUR
5 0.5 to 5sec 5 0.5 to 5hour
10 1 to 10sec 10 1 to 10hour
0.5 0.05 to 0.5min 0.5 0.5 to 5hour
1 0.1 to 1min 1 1 to 10hour
MIN 10H
5 0.5 to 5min 5 5 to 50hour
10 1 to 10min 10 10 to 100hour

Output Operation Mode


● AT8N ● AT11DN/AT11EN
Display Output operation mode Display Output operation mode
A Power ON Delay A Signal ON Delay
A1 Power ON Delay1 (One-Shot output) F Flicker (OFF Start)
B Power ON Delay2 F1 Flicker1 (ON Start)
F Flicker (OFF Start) C Signal OFF Delay
F1 Flicker1 (ON Start) D Signal ON/OFF Delay
I Interval I Interval

K-64
Multi Function Analog Timer
Output Operation Mode (AT8N) [t: Setting time, t > t-a, Rt: Return time, Rt1>Rt] (A)
Photoelectric
Sensors
Mode Time chart
(B)
A t Rt1 t Rt1 t-a Fiber
Optic
Sensors
Power 2-7

Time limit contact N.C. 1-4 (8-5) (C)


Door/Area
Sensors
Power ON Delay Time limit contact N.O. 1-3 (8-6)
(D)
Time limit output indicator Proximity
Sensors
Operation/Power indicator
(E)
A1 t Rt1 t Rt1 t-a Pressure
Sensors
Power 2-7
Time limit contact N.C. 8-5 (F)
0.5sec 0.5sec Rotary
Time limit contact N.O. 8-6 Encoders

Power ON Delay1 Instantaneous limit contact N.C. 1-4 (G)


Connectors/
(One-Shot output) Instantaneous limit contact N.O. 1-3 Connector Cables/
Sensor Distribution
Time limit output indicator Boxes/Sockets

Operation/Power indicator (H)


※One- Shot output is 0.5sec fixed. Temperature
Controllers

B t Rt1 t Rt1 t-a


(I)
Power 2-7 SSRs / Power
Controllers
Time limit contact N.C. 8-5

Time limit contact N.O. 8-6 (J)


Counters
Power ON Delay2 Instantaneous limit contact N.C. 1-4

Instantaneous limit contact N.O. 1-3


(K)
Timers
Time limit output indicator
Operation/Power indicator
(L)
Panel
F t t t-a Rt1 t t t Meters

Power 2-7
(M)
Tacho /
Time limit contact N.C. 1-4 (8-5) Speed / Pulse
Meters
Flicker Time limit contact N.O. 1-3 (8-6)
(OFF Start) (N)
Time limit output indicator Display
Units
Operation/Power indicator
(O)
Sensor
F1 t t t-a Rt1 t t t Controllers

Power 2-7
(P)
Time limit contact N.C. 8-5 Switching
Mode Power
Time limit contact N.O. 8-6 Supplies

Flicker1 Instantaneous limit contact N.C. 1-4 (Q)


Stepper Motors
(ON Start) & Drivers
Instantaneous limit contact N.O. 1-3 & Controllers

Time limit output indicator (R)


Graphic/
Operation/Power indicator Logic
Panels

I t Rt1 t Rt1 t-a (S)


Field
Power 2-7 Network
Devices
Time limit contact N.C. 8-5
(T)
Time limit contact N.O. 8-6 Software

Interval Instantaneous limit contact N.C. 1-4


Instantaneous limit contact N.O. 1-3

Time limit output indicator


Operation/Power indicator

※In case of F, F1 output operation mode, setting time should be over 100ms.
If not, it may cause abnornal output operation due to under 100ms of setting time.

K-65
ATN Series
Output Operation Mode (AT11DN/AT11EN) [t: Setting time, t=t1+t2, t>t-a]
Mode Time chart

A t t1 t2
Power 2-10
START 2-6
INHIBIT 2-5
RESET 2-7
Signal ON Delay Time limit contact N.C.
Time limit contact N.O.
Time limit output indicator
Operation/Power indicator

F t t t-a t t1 t2

Power 2-10
START 2-6
INHIBIT 2-5
Flicker RESET 2-7
(OFF Start) Time limit contact N.C.
Time limit contact N.O.
Time limit output indicator
Operation/Power indicator

F1 t t t-a t t1 t2

Power 2-10
START 2-6
INHIBIT 2-5
Flicker1 RESET 2-7
(ON Start) Time limit contact N.C.
Time limit contact N.O.
Time limit output indicator
Operation/Power indicator

C t t-a t-a t1 t2

Power 2-10
START 2-6
INHIBIT 2-5
RESET 2-7
Signal OFF Delay Time limit contact N.C.
Time limit contact N.O.
Time limit output indicator
Operation/Power indicator

D t t t-a t1 t2 t-a t t-a t-a

Power 2-10
START 2-6
INHIBIT 2-5
RESET 2-7
Signal ON/OFF Delay Time limit contact N.C.
Time limit contact N.O.
Time limit output indicator
Operation/Power indicator

I t t t t-a t-a t1 t2

Power 2-10
START 2-6
INHIBIT 2-5
RESET 2-7
Interval Time limit contact N.C.
Time limit contact N.O.
Time limit output indicator
Operation/Power indicator

※If power is cut or the RESET terminal is short-circuited, the titmer will be RESET.
※If the INHIBIT terminal is short-circuited during a time limit operation, the time will stop.
※In case of F, F1 output operation mode, setting time should be over 100ms.
If not, it may cause abnormal output operation due to under 100ms of setting time.

K-66
Multi Function Analog Timer
Proper Usage Common (A)
Photoelectric
Please connect DC power input after checking polarity of Sensors
Input connection (AT11DN/AT11EN) power.
Power circuit of AT11DN/EN timer does not use trans. 12VDC, 24VDC, 24VAC power supply should be insulated (B)
Fiber
Use isolation transformer which secondary part is not and limited voltage/current or Class 2, SELV power supply Optic
Sensors
grounded as (Figure 1) to cut off peripheral current flow device.
for supplied power to external input deivces. When applying the power to the timer, please apply the (C)
Door/Area
rated power at the moment by switch, relay, etc. Sensors
(Figure 1) AT11DN/AT11EN
Otherwise it might cause malfunction.
(D)
START When supply the power to the timer, connection shown Proximity
Sensors
RESET in (Figure 4) might cause malfunction due to leakage
Power
INHIBIT current through R and C. (E)
Please connect R and C as shown in (Figure 5) to Pressure
Sensors
prevent malfunction.
(F)
(Figure 4) (Figure 5)
Main circuit

Rotary
Encoders
Leakage
current (G)
Connectors/
R

Power

Power
Rectification Isolation Connector Cables/
<sensor> circuit transformer Sensor Distribution

Timer

Timer
R C T C Boxes/Sockets
T
<extermal sensor power supply>
(H)
Temperature
As (Figure 2), if using terminal ⑩ as common terminal of Controllers

input signal, it may cause damage to inner circuit of It might cause malfunction if changing the setting time, (I)
AT11DN/EN timer. Use terminal ② as common terminal time range or operation mode during unit operating unit. SSRs / Power
Controllers
referring to (Figure 3). Please change the setting time, time range or operation
(Figure 2) (Figure 3) mode after cut the power off.
(J)
Do not use this unit at below places. Counters
INHIBIT RESET
• Place where there are severe vibration or impact.
START START • Place where strong alkalis or acids are used. (K)
RESET INHIBIT • Place where there are direct ray of the sun. Timers

• Place where strong magnetic field or electric noise are


generated. (L)
Panel
Installation environment Meters
Power Power
• Indoors
(M)
• Altitude max. 2,000m Tacho /
In order to apply input signals (INHIBIT, START, RESET), • Pollution degree 2
Speed / Pulse
Meters
short-circuit the terminal no. ②-⑤, ②-⑥ or ②-⑦. It may • Installation category Ⅱ
cause internal circuit damage by wrong connections. (N)
Display
Do not wire INHIBIT, START, RESET signal input line with Units

power line, high voltage line in parallel.


(O)
Sensor
Controllers

(P)
Switching
Mode Power
Supplies

(Q)
Stepper Motors
& Drivers
& Controllers

(R)
Graphic/
Logic
Panels

(S)
Field
Network
Devices

(T)
Software

K-67