M4200 Process Alarm Monitor

• Compact unit for flush mounting


• Programmable LED colour change (red, green or yellow)
• Special indication of the first alarm 1 OVERLOAD
• 8 input channels supporting normally open or normally 2 HIGH WATER TEMP.
closed contacts
3 LOW FREQUENCY
• Individual LED indication of each of the 8 inputs
• Individual time delay on all channels 4 HIGH FREQUENCY
• 2 individual blocking modes for easy service 5 FUEL LEVEL LOW
• Special indication of cable break or short circuit 6 FUEL LEAKAGE
• PC based programming via RS232
• 1 common output relay for siren 7 VALVE 1 OPEN
• 2 programmable output relays 8 VALVE 2 OPEN
• 3 programmable “Open Collector” outputs
POWER
ON
RESET TEST ALARM

Figure 1. Front of M4200

Application Label layout When using cable monitoring it is


The M4200 Alarm Monitor provides A text description for the LEDs can possible to translate both cable break
a cost effective solution, with the be printed on the blank legend card and short circuit faults into an alarm
possibility of monitoring 8 individual situated between the two covers at the (cable fault) whenever a NO or an NC
processes. All inputs will accept any front. contact is connected to the input(s).
combination of NO or NC contacts. SELCO A/S also provides a Microsoft®
Office Word template for doing this in Cable faults are indicated with short
Each input can be programmed to an easy manner. flashing pulses on the corresponding
control both of the two alarm relays for alarm channels. Cable fault indications
group alarm outputs. All inputs will in Cable Monitoring will be overridden by activation of
default mode activate the alarm relay Cable monitoring provides extra input alarms and indicated with normal
and the siren relay. The delays for the security to the alarm system. flash or steady light indication.
inputs can be individually selected
between 25 milliseconds and 999
seconds.
Alarm input
Function
When alarm input is activated, the LED LED
goes flashing and the interconnected
output(s), alarm 1 and the siren goes Output 1-4
ON.
Alarm 1
When the reset button is being
activated, the LED goes steady and Alarm 2
the siren goes OFF. The interconnected Siren
output(s) is still ON.
When the alarm input is de-activated, Reset
LED goes OFF, together with alarm 1
and the interconnected outputs.
Figure 2. Function Diagram, Default Scenario
Please refer to the function diagram in
figure 2.
Specifications
M4200 Process Alarm Monitor
SELCO Worldwide Voltage supply 8.4 - 60 VDC
8.4 - 50 VAC
Power Consumption Max 180mA
Ambient temp. range ÷15 ºC / +70 ºC
Relay output (load capacity) Max. 250VAC / 6A
Regarding DC load capacity, refer to the user manual
Open collector output (load capacity)Max. 60VDC / 700mA per output
LED flash frequency: Slow flashing 1.25Hz ±10%
LED flash frequency: Quick flashing 5Hz ±10%
Min. input delay 25 m. Sec
Resistance in sensing cable 1000Ω (full length)
Programming Dip switches or PC based configuration
Belgium New Zealand RS232 Bits per second 9600
Brazil Norway RS232 Data bit 8
Bulgaria Pakistan RS232 Parity None
Canada Peru RS232 Stop bit 1
Chile Philippines RS232 Flow control None
China Poland RS232 Line delay (ASCII Setup) 50 milliseconds
Croatia Portugal RS232 Character delay (ASCII Setup) 0 milliseconds
Egypt Romania Burn-in 50 hours before final test
Finland Russia Maritime application standards IEC 60945
France Singapore Industrial application standards EN 61000-4-3, EN 61000-4-4, EN 61000-4-5,
Germany South Africa EN 61000-4-6
Greece South Korea Weight 0.222 Kg
Iceland Spain Dimension (mm) 96 x 96 x 20 (H x W x D)
India Sri Lanka Panel cut out (mm) 92 x 92
Indonesia Sweden Protection degree at front IP 54
Iran Taiwan
Italy Thailand
Japan Turkey Dimming
Lebanon United Kingdom It is possible to adjust the brightness
Malaysia U.S.A. of the LEDs on all multiple units 1 IN1
2 IN2
Betonvej 10
DK-4000 Roskilde
O
U
OUT1 19
OUT2 20
T
Mexico Venezuela by pressing the button “Test” or the 3 IN3 I
N
Phone: +45 70261122
Fax: +40 70262522
Internet: www.selco.com
P
U
OUT3 21
4 IN4 P OUT4 22
Netherlands Vietnam external positioned button connected to 5 IN5 U
T
T
S SYNC 23
6 IN6
terminal 11, for more than 10 seconds.
S
+ 24
7 IN7
9 01 POWER 25
8 IN8
7 8

23

- 26
9 +REF OUT 6 4
5

Dimming is done in 8 consecutive 10 GND


27
ON DIP 28
levels. The default brightness level is 11 RESET
12 TEST ALARM1 29
1 2 3 4 5 6 7 8
re-obtained when the lowest level has 13 BLOCK1
14 BLOCK2
30
ON DIP 31
been obtained. 15 GND
ALARM2 32
1 2 3 4 5 6 7 8
33
RS232

Programming
34
ACK SET SIREN 35

Sunken into the rear of the Alarm


Monitor, one rotary switch and two dip
switches are positioned. Figure 3. Rear of M4200

With the rotary switch it is possible PC based configuration


to select which part of the program M4200 can be configured via the RS232
to be adjusted, channel selection (1- interface. A standard ANSI / VT100
8), operational mode (0) or general terminal is used as the programming
functions (9). tool. SELCO A/S recommends
Microsoft® Hyper Terminal.
Main office: With the two dip switches it is possible
SELCO A/S to adjust the program selected on the For further information please refer
Betonvej 10 rotary switch, e.g. time delay, reset to the User Manual which can be
DK-4000 Roskilde settings, block mode, LED colour etc. downloaded from www.selco.com.
Denmark
Phone: + 45 7026 1122
M4295-84UK

Fax: + 45 7026 2522


e-mail: selco.dk@selco.com
www.selco.com

Potrebbero piacerti anche