Sei sulla pagina 1di 44

P0365-P0446-E.qxd 08.11.

6 2:09 PM Page 391

Regulator with Built-in Pressure Gauge


Filter Regulator with Built-in Pressure Gauge
Series ACG /ARG /AWG

Visibility of pressure gauge is improved


in various installation places

AC
When mounting
Equipment on an equipment
AF
at approximately
OUT

foot level AR
AL
Floor

AW
When mounting
on a panel AG
AV
SMC

AF800
AF900
Panel

391
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 392

Installation and removal of pressure gauge Mounting angle of pressure gauge is selectable
cover is possible with one-touch. (PAT.PEND.) depending on the piping direction
∗ Mounting angle can be changed as desired. For details, refer to “Procedure for
Easy to adjust limit indicator. replacing or changing the mounting angle of a pressure gauge” on page 434.

Mounting angle 0° 90°

Mounting IN OUT IN OUT

MPa
angle view MPa
P P
US K US K
H to L O C H to L O C

Mounting angle 180° 270°


MPa
Mounting IN OUT IN OUT

MPa
angle view
P P
US K US K
H to L O C H to L O C

∗ Pressure gauge will not be revolved even


Pressure gauge anti-revolving mechanism (PAT.PEND.) after the handle is operated.

Space saving, Labor saving


Panel-cut for pressure gauge is not necessary.
In the case of panel mounting, the number of holes for taking out the products (pressure
gauge plus regulator handle parts) can be reduced into one location. By changing the
angle of pressure gauge, the internal volume of a panel can be used effectively.
 Mounting example: In the case of aligning three ARG30s in line.

Mounting at 90° (In the case of restricted in side direction) Mounting at 45° (In the case of considering the effectiveness of panel)
∗ Contact SMC separately, since it will be made to order. (Refer to page 422.)
Surface of panel
OUT Surface of panel
SMC

MPa MPa MPa MPa MPa MPa


P K P K P K P K P K P K
U C U C U C U C U C U C
SH SH SH SH SH SH
to L O to L O to L O to L O to L O to L O

IN
66

Bottom of panel
Bottom of panel
45°

IN 1 IN 1 IN 1
IN

IN

IN
SM

SM

SM
C

C
1

1
SMC

SMC

SMC

2
O

O
U

2 OUT 2 OUT 2 OUT


T

In the case of ARG30, dimension in height


can be reduced by approx. 30 mm.

392
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 393

Standard Combinations

Components
Regulator with Built-in Filter Regulator with
Combination Model Port size Air filter Pressure Gauge Built-in Pressure Gauge Lubricator Mist separator
AF ARG AWG AL AFM
P. 327 P. 411 P. 423 P. 357 P. 338

AF + ARG + AL P. 396
ACG20 1/8, 1/4 AF20 ARG20 AL20

ACG30 1/4, 3/8 AF30 ARG30 AL30

ACG40 1/4, 3/8, 1/2 AF40 ARG40 AL40

AWG + AL P. 399
ACG20A 1/8, 1/4 AWG20 AL20

ACG30A 1/4, 3/8 AWG30 AL30

ACG40A 1/4, 3/8, 1/2 AWG40 AL40

AF + ARG P. 401
ACG20B 1/8, 1/4 AF20 ARG20

ACG30B 1/4, 3/8 AF30 ARG30

ACG40B 1/4, 3/8, 1/2 AF40 ARG40

AF + AFM + ARG P. 403


ACG20C 1/8, 1/4 AF20 ARG20 AFM20

ACG30C 1/4, 3/8 AF30 ARG30 AFM30

ACG40C 1/4, 3/8, 1/2 AF40 ARG40 AFM40

AWG + AFM P. 405


ACG20D 1/8, 1/4 AWG20 AFM20

ACG30D 1/4, 3/8 AWG30 AFM30


AC
ACG40D 1/4, 3/8, 1/2 AWG40 AFM40
AF
INDEX AR
 Air Combination  Regulator with Built-in Pressure Gauge
Air Filter + Regulator with Built-in Pressure Gauge + Lubricator Regulator with Built-in Pressure Gauge
AL
ACG20/30/40 P. 396
P.4 ARG20/30/40 P. P.20
412
Filter Regulator with Built-in Pressure Gauge + Lubricator Regulator with Built-in Pressure Gauge with Back Flow Mechanism
AW
ACG20A/30A/40A P. 399
P.7 ARG20K/30K/40K P. P.24
416
Air Filter + Regulator with Built-in Pressure Gauge
AG
ACG20B/30B/40B P. 401
P.9  Filter Regulator with Built-in Pressure Gauge
AV
Air Filter + Mist Separator + Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge
ACG20C/30C/40C P. P.11
403 AWG20/30/40 P. P.31
424 AF800
Filter Regulator with Built-in Pressure Gauge + Mist Separator Filter Regulator with Built-in Pressure Gauge with Back Flow Mechanism
AF900
ACG20D/30D/40D P. P.13
405 AWG20K/30K/40K P. P.35
428

393
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 394

Series ACG

How to Order

ACG 30 03 G1
Option
Symbol Description Applicable model
Body size Nil — —
Symbol Port size 1 (8) 0.02 to 0.2 MPa setting ACG20 to 40
20 1/8 2 Metal bowl ACG20 to 40
30 3/8 3 Lubricator with drain cock ACG20 to 40
40 1/2 6 Nylon bowl ACG20 to 40
8 Metal bowl with level gauge ACG30, 40
C With bowl guard ACG20
Model combination
Combination J (9) Filter case with drain guide ACG20 to 40

Regulator Filter N Non-relieving type ACG20 to 40


Symbol Air with Regulator Mist R Flow direction: Right to left ACG20 to 40
filter Built-in Lubricator with Built-in separator Drain cock with barb fitting:
ACG30, 40
Pressure Pressure W ø6 x ø4 nylon tubing
Gauge Gauge
Y Regulator with upward facing handle ACG20 to 40
Nil (1) (2) (3) — — Name plate and pressure gauge in
(10)
A — — (2) (1) — Z imperial units (psi), caution plate for ACG20 to 40
(1) bowl (psi • °F)
B (1) (2) — — —
∗ When more than one specification is required, indicate in
C (1) (3) — — (2) ascending alphanumeric order.
Note 8) Adjusting spring and pressure gauge (full-span 0.3
D — — — (1) (2) MPa) are different from those for the standard
Note 1) Wall mount is not available for size 20 specification. Outlet pressure may increase by 0.2
regulator with downward facing handle in B MPa or more.
combination. Contact SMC when wall mount Note 9) Without a valve function.
is needed. Note 10) For thread type NPT.
Note 2) The number inside ( ) indicates the This product is for overseas use only according to the
combination order counted from the inlet new Measurement Law. (The SI unit type is provided
side. for use in Japan.) Both MPa and psi are used for the
pressure switch unit.
Attachment
Thread type Attachment Applicable Port size for
Symbol Description mounting intermediate
Symbol Type position model air release

Nil Rc Nil

N (3)
NPT AF + ARG + [K] + AL ACG20: 1/8
ACG20 to 40
Check
K valve ACG30: 1/4
F(4) G AWG + [K] + AL ACG20A to 40A ACG40: 3/8
Note 3) Drain guide is NPT1/8 for ACG20 and NPT1/4 for
AF + ARG + [S] + AL ACG20 to 40
ACG30 and 40. Auto-drain port is provided with (7) Pressure
ø3.8" One-touch fitting (applicable to ACG30 and S switch
AF + [S] + ARG ACG20B to 40B
40).
AF + AFM + [S] + ARG ACG20C to 40C
Note 4) Drain guide is G1/8 for ACG20 and G1/4 for
ACG30 and 40. AF + ARG + AL + [V] ACG20 to 40
Residual
AWG + AL + [V] ACG20A to 40A
pressure
Port size V relief AF + ARG + [V] ACG20B to 40B
Port Body size 3 port AF + AFM + ARG + [V] ACG20C to 40C
Symbol size valve
20 30 40 AWG + AFM + [V] ACG20D to 40D
01 1/8  — — Note 6) When more than one attachment is required, order in
02 1/4    alphabetical order.
Note 7) Pressure switch cannot be mounted on the inlet and outlet
03 3/8 —   sides of an ARG with an upward facing handle (optional
04 1/2 — —  specification: -Y).

Mounting Angle of Pressure Gauge


Accessory
Symbol G1
Symbol Description Applicable model
Mounting angle 0°
Nil — —
C Float type auto-drain (Normally closed) ACG20 to 40
D Float type auto-drain (Normally open) ACG30, 40 Mounting angle IN OUT
view
PU
MPa
SH L OCK
to

Mounting angle of pressure gauge °0


Note 5) Mounting angle of pressure gauge is G1 only.
If other mounting angles are needed, contact SMC. Mounting angle
view OUT IN
∗ Possible to change to the optional mounting angles.
For details, refer to page 434, “Procedure for replacing or changing (-R specification) MPa
PU
the mounting angle of a pressure gauge”. SH L OCK
to

394
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 395

Air Combination Series ACG

Accessory/Optional Combinations

: Combination available : Combination not available : Varies depending on a model : Available only with NPT thread
F.R.L. unit applicable model

Symbol
Combination
Accessory Option
Accessory/ ACG30 ACG30A ACG30B ACG30C ACG30D
ACG20 ACG20A ACG20B ACG20C ACG20D
Optional specifications C D 1 2 3 6 8 C J N RW Y Z ACG40 ACG40A ACG40B ACG40C ACG40D

Float type auto drain (N.C.) C


Float type auto drain (N.O.) D
0.02 to 0.2 MPa setting -1
Metal bowl -2
Lubricator with drain cock -3
Nylon bowl -6
Metal bowl with level gauge -8

With bowl guard -C


Drain guide -J
Non-relieving type -N
Flow direction: Right to left -R
Drain cock with barb fitting -W
Regulator upward facing handle -Y
Name plate, caution plate for bowl, and
pressure gauge in imperial units (psi, °F) -Z

Attachments

Port size Function

Check valve 1/8, 1/4, 3/8 Prevents back flow from lubricator. P. 407

Pressure switch Compact switch P. 408

Residual pressure relief


3 port valve 1/8, 1/4, 3/8, 1/2 Releases residual pressure in lines. P. 409

Accessories AC
Refer to page 410 for spacers and brackets.

AF
AR
AL
AW
AG
AV
AF800
AF900

395
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 396

Air Combination

Air Filter + Regulator + Lubricator

Series ACG20/30/40
JIS Symbol

ACG20 ACG40 Air filter Regulator Lubricator


Standard Specifications
Model ACG20 ACG30 ACG40
Air filter AF20 AF30 AF40
Component Regulator ARG20 ARG30 ARG40
Lubricator AL20 AL30 AL40
1/8 1/4 1/4
Port size 3/8
1/4 3/8 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 μm
Recommended lubricant Class 1 turbine oil (ISO VG32)
Regulator construction Relieving type
Bowl material Polycarbonate
Bowl guard Optional Standard
Sight dome material Polycarbonate
Mass (kg) 0.78 1.11 1.87

Accessory/Attachment Part No.


Accessory/Attachment part no.
Description Model ACG20 ACG30 ACG40
(1) Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure gauge
Optional 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
Acces-

Normally closed AD27 AD37 AD47


sory

(2)
Float type auto drain
Normally open — AD38 AD48
Spacer Y200 Y300 Y400
Attachment

Spacer with bracket Y200T Y300T Y400T


(3)
Check valve (4) AKM2000-01, (02) AKM3000-(01), 02 AKM4000-(02), 03
(4)
Pressure switch (5) IS1000M-20 IS1000M-30 IS1000M-40
Residual pressure relief 3 port valve (4) VHS20-01, 02 VHS30-02, 03 VHS40-02, 03, 04
Note 1) Contact SMC regarding the connection thread NPT and pressure gauge supply for psi unit specifications.
Note 2) Minimum operating pressure: 0.1 MPa for N.O. type, 0.1 MPa for N.C. type (AD27) and 0.15 MPa for N.C. type (AD37 and 47). Contact SMC for psi and °F
specifications.
Note 3) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 4) Separate spacers are required for modular unit.
Note 5) Pressure switch cannot be mounted on the inlet and outlet sides of an ARG with an upward facing handle (optional specification: -Y).

396
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 397

Air Combination Series ACG20/30/40

Flow Characteristics Condition: Inlet pressure 0.7 MPa

ACG20 Rc1/4 ACG30 Rc3/8 ACG40 Rc1/2


0.6 0.6 0.6
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)


0.5 0.5 0.5

0.4 0.4 0.4

0.3 0.3 0.3

0.2 0.2 0.2

0.1 0.1 0.1

0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Pressure Characteristics Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa, Flow rate 20 l/min (ANR)

ACG20 Rc1/4 ACG30 Rc3/8 ACG40 Rc1/2


0.25 0.25 0.25

Set point Set point Set point


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)


0.2 0.2 0.2

0.15 0.15 0.15

0 0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

Specific Product Precautions


Be sure to read before handling.
Refer to front matters 42 and 43 for Safety Instructions and pages 287 to 291 for F.R.L. Precautions.

Piping Selection
Warning Caution
1. When mounting a check valve, make sure the arrow (IN side) 1. Mounting a 3 port valve for residual pressure release on the IN
points in the correct direction of air flow. side of the lubricator can cause lubricant to back flow. Take
measures to prevent lubricant from splashing by installing a
filter on the EXH port.
Selection 2. An F.R.L. unit shipped from the plant has its model number
Warning labeled. However, components that are combined together
during the distribution process do not have a label on them.
1. Float type auto drain
Operate under the following conditions to avoid malfunction. AC
Air Supply
<N.O. type>
AF
• Operating compressor: 0.75 kW (100 l/min (ANR)) or more.
When using 2 or more auto drains, multiply the value above
Caution
by the number of auto drains to find the capacity of the 1. Use an air filter with 5 μm or less filtration rating on the inlet AR
compressors you will need. side of the valve to avoid any damage to the seat caused by
dust when mounting a 3 port valve for residual pressure AL
For example, when using 2 auto drains, 1.5 kW (200 l/min
release on the inlet side.
(ANR)) of the compressor capacity is required.
• Operating pressure: 0.1 MPa or more. AW
<N.C. type>
• Operating pressure for AD27: 0.1 MPa or more. AG
• Operating pressure for AD37/47: 0.15 MPa or more.
2. Use a regulator or filter regulator with a back flow mechanism AV
when mounting a 3 port valve for residual pressure release on
the IN side to ensure the release of the residual pressure. AF800
AF900
Otherwise, residual pressure will not be fully released.

397
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 398

Series ACG20/30/40

Dimensions
ACG20 Standard ACG30/40 Standard
Downward facing handle Downward facing handle
A
P G
A E F øL
2x
P G
L
E F

2

H1
IN OUT
C

H2 H1
SMC

IN OUT

2xL

H2
SMC
4xL

OUT

J
2xK M

B
B

4xK M
Port size
Port size
for maintenance

Drain N
Min. clearance

for maintenance
Min. clearance
Drain
D

Air filter Regulator Lubricator

D
Air filter Regulator Lubricator

ACG20 Optional (-Y) ACG30/40 Optional (-Y)


Upward facing handle Upward facing handle
A
E F P G
A
E F P G

øL
C
øL

2x
C

x
2

H1
H1

IN SMC
OUT IN SMC
OUT
4xL

H2

2xL

H2
J

OUT
OUT
B

4xK M 2xK M
B

Port size
Port size
O
S
for maintenance

Drain
Min. clearance
D

Air filter Regulator Lubricator


maintenance

Drain
clearance
Min.
D

for

Air filter Regulator Lubricator

Applicable model ACG20 ACG30/40


Accessory/Optional
specifications With auto drain (N.C.) Metal bowl With drain guide With auto drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B

B
B

Dimensions
B

N.O.: Black
B

N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 x 0.8 Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604

Standard specifications
Model Port size Bracket mount
A B C D P
E F G H1 H2 J K L øL M
ACG20 1/8, 1/4 126 87 36 60 28.5 41.5 43 30 24 — (1) — (1) — (1) — (1) 5.5 3.2
ACG30 1/4, 3/8 167 115 41 80 30 55 57 41 35 35 — 14 7 7 4
ACG40 1/4, 3/8, 1/2 220 147 48 110 38 72.5 75 50 40 40 — 18 9 9 4

Accessory/Optional specifications
Model Upward facing handle (2) With auto drain (3) With barb fitting (3) With drain guide (3) Metal bowl (3) Metal bowl with level gauge (3)
C H2 J K L B B B B B
ACG20 87 24 33 12 5.5 105 — 91 87 —
ACG30 108.5 35 — 14 7 156 123 122 128 148
ACG40 114.5 40 — 18 9 186 155 154 160 180
Note 1) In the case of the ACG20’s standard specification (downward facing handle), the wall mounting is not possible using the lower side mounting hole on the spacer with a
bracket. Use the upper side mounting hole when wall mounting.
Note 2) In the case of the upward facing handle in the optional specification, the C dimension will change. Also, in the case of the ACG20, wall mounting is possible by using the
lower side mounting hole on the spacer with a bracket.
Note 3) For the accessory/optional specifications (with auto drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level gauge), the total length (B dimension) will vary.
398
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 399

Air Combination

Filter Regulator + Lubricator

Series ACG20A/30A/40A
JIS Symbol

Filter regulator Lubricator


ACG20A ACG40A
Standard Specifications
Model ACG20A ACG30A ACG40A
Filter regulator AWG20 AWG30 AWG40
Component
Lubricator AL20 AL30 AL40
1/8 1/4 1/4
Port size 3/8
1/4 3/8 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 μm
Recommended lubricant Class 1 turbine oil (ISO VG32)
Filter regulator construction Relieving type
Bowl material Polycarbonate
Bowl guard Optional Standard
Sight dome material Polycarbonate
Mass (kg) 0.65 0.86 1.55

Accessory/Attachment Part No.


Accessory/Attachment part no.
Description Model ACG20A ACG30A ACG40A
(1) Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure gauge
Optional 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
Acces-

Normally closed AD27 AD37 AD47


sory

(2)
Float type auto drain
Normally open — AD38 AD48
Spacer
Attachment

Y200 Y300 Y400


Spacer with bracket Y200T Y300T Y400T
Check valve (3)
(4) AKM2000-01, (02) AKM3000-(01), 02 AKM4000-(02), 03
Residual pressure relief 3 port valve (4) VHS20-01, 02 VHS30-02, 03 VHS40-02, 03, 04
Note 1) Contact SMC regarding the connection thread NPT and pressure gauge supply for psi unit specifications. AC
Note 2) Minimum operating pressure: 0.1 MPa for N.O. type, 0.1 MPa for N.C. type (AD27) and 0.15 MPa for N.C. type (AD37 and 47). Contact SMC for psi and °F
specifications.
Note 3) For F.R.L. units, port sizes not in ( ) are for standard application.
AF
Note 4) Separate spacers are required for modular unit.
AR
AL
AW
AG
AV
AF800
AF900

399
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 400

Series ACG20A/30A/40A

Dimensions
ACG20A N A
E P G

øL

H2 H1
IN SMC OUT
2xL

J
OUT
B

2xK
M
Port size

O S S O
for maintenance
Min. clearance

Drain
D

Filter regulator Lubricator

ACG30A/40A N A
E P G
C

øL

H1
IN SMC OUT

H2
L

OUT

M
B

K
Port size
for maintenance
Min. clearance

Drain
D

Filter regulator Lubricator

Applicable model ACG20A ACG30A/40A


Accessory/Optional
specifications With auto drain (N.C.) Metal bowl With drain guide With auto drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B

B
B

Dimensions
B

N.O.: Black
B

N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 x 0.8 Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604

Standard specifications
Model Port size Bracket mount
A B C D N P
E G H1 H2 J K L øL M
ACG20A 1/8, 1/4 83 87 91 60 2.5 26 41.5 30 24 24 33 12 5.5 5.5 3.2
ACG30A 1/4, 3/8 110 115 108.5 80 2.5 30 55 41 35 35 — 14 7 7 4
ACG40A 1/4, 3/8, 1/2 145 147 114.5 110 0 38 72.5 50 40 40 — 18 9 9 4
Note)
Accessory/Optional specifications
Model With auto drain With barb fitting With drain guide Metal bowl Metal bowl with level gauge
B B B B B
ACG20A 105 — 91 87 —
ACG30A 156 123 122 128 148
ACG40A 186 155 154 160 180
Note) For the accessory/optional specifications (with auto drain, with barb fitting, with drain guide, metal bowl, or with level gauge), the total length (B dimension) will vary.

400
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 401

Air Combination

Air Filter + Regulator

Series ACG20B/30B/40B
JIS Symbol

ACG20B ACG40B Air filter Regulator


Standard Specifications
Model ACG20B ACG30B ACG40B
Air filter AF20 AF30 AF40
Component
Regulator ARG20 ARG30 ARG40
1/8 1/4 1/4
Port size 3/8
1/4 3/8 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 μm
Regulator construction Relieving type
Bowl material Polycarbonate
Bowl guard Optional Standard
Mass (kg) 0.56 0.74 1.25

Accessory/Attachment Part No.


Accessory/Attachment part no.
Description Model ACG20B ACG30B ACG40B
(1) Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure gauge
Optional 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
Acces-

Normally closed AD27 AD37 AD47


sory

(2)
Float type auto drain
Normally open — AD38 AD48
Attachment

Spacer Y200 Y300 Y400


Spacer with bracket Y200T Y300T Y400T
(3)
Pressure switch (4) IS1000M-20 IS1000M-30 IS1000M-40
Residual pressure relief 3 port valve (3) VHS20-01, 02 VHS30-02, 03 VHS40-02, 03, 04
Note 1) Contact SMC regarding pressure gauge supply for psi unit specifications.
Note 2) Minimum operating pressure: 0.1 MPa for N.O. type, 0.1 MPa for N.C. type (AD27) and 0.15 MPa for N.C. type (AD37 and 47). Contact SMC for psi and °F
specifications.
Note 3) Separate spacers are required for modular unit. AC
Note 4) Pressure switch cannot be mounted on the inlet and outlet sides of an ARG with an upward facing handle (optional specification: -Y).

AF
AR
AL
AW
AG
AV
AF800
AF900

401
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 402

Series ACG20B/30B/40B

Dimensions
ACG20B Standard ACG30B/40B Standard
Downward facing handle Downward facing handle
A N
A N E P G
E P G øL
øL

H1
C

H2 H1
IN SMC
OUT IN OUT
SMC
2xL

H2
J

L
B

2xK M M

B
Port size K
Port size
o s
for maintenance

Drain
Min. clearance
D

Air filter Regulator

for maintenance
Drain

Min. clearance
D
Air filter Regulator

ACG20B Optional (-Y) ACG30B/40B Optional (-Y)


Upward facing handle Upward facing handle
A N
E P G
A N
E P G

øL
C

øL
C

H1
H2 H1

IN SMC
OUT IN SMC
OUT
2xL

H2
J

L
B

2xK M M
B

Port size K
Port size
O
o s S
for maintenance

Drain
Min. clearance
D

Air filter Regulator


maintenance

Drain
clearance
Min.
for
D

Air filter Regulator

Applicable model ACG20B ACG30B/40B


Accessory/Optional
specifications With auto drain (N.C.) Metal bowl With drain guide With auto drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B
B

Dimensions
B

N.O.: Black
B

N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 x 0.8 Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604

Standard specifications
Model Port size Bracket mount
A B C D N P
E G H1 H2 J K L øL M
ACG20B 1/8, 1/4 83 87 29 60 2.5 28.5 41.5 30 — (1) — (1) — (1) — (1) — (1) — (1) 3.2
ACG30B 1/4, 3/8 110 115 41 80 2.5 29.5 55 41 35 35 — 14 7 7 4
ACG40B 1/4, 3/8, 1/2 145 147 48 110 0 38 72.5 50 40 40 — 18 9 9 4

Accessory/Optional specifications
Metal bowl with (3)
Model Upward facing handle (2) With auto drain (3)
With barb fitting (3) With drain guide (3) Metal bowl (3) level gauge
C H1 H2 J K L øL B B B B B
ACG20B 87 24 24 33 12 5.5 5.5 105 — 91 87 —
ACG30B 108.5 35 35 — 14 7 7 156 123 122 128 148
ACG40B 114.5 40 40 — 18 9 9 186 155 154 160 180
Note 1) In the case of the ACG20B’s standard specification (downward facing handle), the wall mounting is not possible using the lower side mounting hole on the spacer with a
bracket. Contact SMC.
Note 2) In the case of the upward facing handle in the optional specification, the C dimension will change. Also, in the case of the ACG20B, wall mounting is possible by using
the lower side mounting hole on the spacer with a bracket.
Note 3) For the accessory/optional specifications (with auto drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level gauge), the total length (B dimension) will vary.
402
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 403

Air Combination

Air Filter + Mist Separator + Regulator

Series ACG20C/30C/40C
JIS Symbol

ACG20C ACG40C Air filter Mist separator Regulator


Standard Specifications
Model ACG20C ACG30C ACG40C
Air filter AF20 AF30 AF40
Component Mist separator AFM20 AFM30 AFM40
Regulator ARG20 ARG30 ARG40
1/8 1/4 1/4
Port size 3/8
1/4 3/8 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Rated flow (l/min (ANR)) (1) 200 450 1100
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating AF: 5 μm; AFM: 0.3 μm (95% filtered particle size)
(2)
Outlet side oil mist concentration Maximum 1.0 mg/Nm3 (approx. 0.8 ppm)
Regulator construction Relieving type
Bowl material Polycarbonate
Bowl guard Optional Standard
Mass (kg) 0.79 1.06 1.89
Note 1) P1 = 0.7 MPa, 0.5 MPa setting and fully open
Note 2) At compressor discharge 30 mgf/Nm3.

Accessory/Attachment Part No.


Accessory/Attachment part no.
Description Model ACG20C ACG30C ACG40C
Standard 0 to 1.0 MPa
(1) GB2-10AS GB3-10AS GB4-10AS
Pressure gauge
Optional 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
Acces-

Normally closed AD27 AD37 AD47


sory

(2)
Float type auto drain
Normally open — AD38 AD48
Attachment

Spacer Y200 Y300 Y400


Spacer with bracket Y200T Y300T Y400T
(3)
Pressure switch (4) IS1000M-20 IS1000M-30 IS1000M-40
Residual pressure relief 3 port valve (3) VHS20-01, 02 VHS30-02, 03 VHS40-02, 03, 04
AC
Note 1) Contact SMC regarding pressure gauge supply for psi unit specifications.
Note 2) Minimum operating pressure: 0.1 MPa for N.O. type, 0.1 MPa for N.C. type (AD27) and 0.15 MPa for N.C. type (AD37 and 47). Contact SMC for psi and °F AF
specifications.
Note 3) Separate spacers are required for modular unit.
Note 4) Pressure switch cannot be mounted on the inlet and outlet sides of an ARG with an upward facing handle (optional specification: -Y). AR
AL
AW
AG
AV
AF800
AF900

403
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 404

Series ACG20C/30C/40C

Dimensions
ACG20C Standard ACG30C/40C Standard
Downward facing handle Downward facing handle
A N
E F ø L P G
A N 2x
E F øL P G
2x

H1
IN OUT
C

H2 H1
SMC

IN OUT

2xL

H2
SMC
4xL

J
2xK M

B
B

4xK M
Port size
Port size

o s o s
for maintenance

Drain Drain
Min. clearance
D

for maintenance
Drain Drain

Min. clearance
Air filter Mist separator Regulator
D Air filter Mist separator Regulator

ACG20C Optional (-Y) ACG30C/40C Optional (-Y)


Upward facing handle Upward facing handle
A N
E F P G
A N
E F P G

2x
øL
C

2x
C

øL

H1
H2 H1

IN SMC
OUT IN SMC
OUT
4xL

2xL

H2
J
B

4xK M 2xK M
B

Port size
Port size
O
o s o s S
for maintenance

Drain Drain
Min. clearance

Air filter Mist separator Regulator


maintenance
D

Drain Drain
clearance
Min.
for
D

Air filter Mist separator Regulator

Applicable model ACG20C ACG30C/40C


Accessory/Optional
specifications With auto drain (N.C.) Metal bowl With drain guide With auto drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B

B
B
B

Dimensions N.O.: Black


B

N.C.: Gray
1/8
M5 x 0.8 ø10 One-touch 1/4 Barb fitting
Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604

Standard specifications
Model Port size Bracket mount
A B C D N P
E F G H1 H2 J K L øL M
ACG20C 1/8, 1/4 126 87 29 60 2.5 28.5 41.5 43 30 24 — (1) — (1) — (1)
— (1) 5.5 3.2
ACG30C 1/4, 3/8 167 115 41 80 2.5 30 55 57 41 35 35 — 14 7 7 4
ACG40C 1/4, 3/8, 1/2 220 147 48 110 0 38 72.5 75 50 40 40 — 18 9 9 4
Accessory/Optional specifications
Model Upward facing handle (2) With auto drain (3)
With barb fitting (3) With drain guide (3) Metal bowl (3) Metal bowl with level gauge (3)
C H2 J K L B B B B B
ACG20C 87 24 33 12 5.5 105 — 91 87 —
ACG30C 108.5 35 — 14 7 156 123 122 128 148
ACG40C 114.5 40 — 18 9 186 155 154 160 180
Note 1) In the case of the ACG20C’s standard specification (downward facing handle), the wall mounting is not possible using the lower side mounting hole on the spacer with a
bracket. Use the upper side mounting hole when wall mounting.
Note 2) In the case of the upward facing handle in the optional specification, the C dimension will change. Also, in the case of the ACG20C, wall mounting is possible by using
the lower side mounting hole on the spacer with a bracket.
Note 3) For the accessory/optional specifications (with auto drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level gauge), the total length (B dimension) will vary.
404
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 405

Air Combination

Filter Regulator + Mist Separator

Series ACG20D/30D/40D
JIS Symbol

ACG20D ACG40D Filter regulator Mist separator


Standard Specifications
Model ACG20D ACG30D ACG40D
Filter regulator AWG20 AWG30 AWG40
Component
Mist separator AFM20 AFM30 AFM40
1/8 1/4 1/4
Port size 3/8
1/4 3/8 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Rated flow (l/min (ANR)) (1) 150 330 800
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating AWG: 5 μm; AFM: 0.3 μm (95% filtered particle size)
(2)
Outlet side oil mist concentration Maximum 1.0 mgf/Nm3 (approx. 0.8 ppm)
Regulator construction Relieving type
Bowl material Polycarbonate
Bowl guard Optional Standard
Mass (kg) 0.63 0.85 1.52
Note 1) P1 = 0.7 MPa, 0.5 MPa setting and fully open
Note 2) At compressor discharge 30 mgf/Nm3.

Accessory/Attachment Part No.


Accessory/Attachment part no.
Description Model ACG20D ACG30D ACG40D
Standard 0 to 1.0 MPa
(1) GB2-10AS GB3-10AS GB4-10AS
Pressure gauge
Optional 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
Acces-

Normally closed AD27 AD37 AD47


sory

(2)
Float type auto drain
Normally open — AD38 AD48
Attachment

Spacer Y200 Y300 Y400


Spacer with bracket Y200T Y300T Y400T
Residual pressure relief 3 port valve (3) VHS20-01, 02 VHS30-02, 03 VHS40-02, 03, 04
Note 1) Contact SMC regarding pressure gauge supply for psi unit specifications.
Note 2) Minimum operating pressure: 0.1 MPa for N.O. type, 0.1 MPa for N.C. type (AD27) and 0.15 MPa for N.C. type (AD37 and 47). Contact SMC for psi and °F AC
specifications.
Note 3) Separate spacers are required for modular unit.
AF
AR
AL
AW
AG
AV
AF800
AF900

405
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 406

Series ACG20D/30D/40D

Dimensions
ACG20D N
E
A
P G

øL
C

H2 H1
IN SMC OUT
2xL

J
OUT
B

M
2xK
Port size
O
O S O S S
for maintenance
Min. clearance

Drain Drain
D

Filter regulator Mist separator

ACG30D/40D N A
E P G
C

øL

H1
IN SMC OUT

H2
L

OUT

M
B

K
Port size
for maintenance

Drain Drain
Min. clearance
D

Filter regulator Mist separator

Applicable model ACG20D ACG30D/40D


Accessory/Optional
specifications With auto drain (N.C.) Metal bowl With drain guide With auto drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B

B
B
B

Dimensions
B

N.O.: Black
B

N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 x 0.8 Width across flats 17 fitting Applicable tubing: T0604
Width across flats 17

Standard specifications
Model Port size Bracket mount
A B C D N P
E G H1 H2 J K L øL M
ACG20D 1/8, 1/4 83 87 91 60 2.5 26 41.5 30 24 24 33 12 5.5 5.5 3.2
ACG30D 1/4, 3/8 110 115 108.5 80 2.5 30 55 41 35 35 — 14 7 7 4
ACG40D 1/4, 3/8, 1/2 145 147 114.5 110 0 38 72.5 50 40 40 — 18 9 9 4

Accessory/Optional specifications Note)


Model With auto drain With barb fitting With drain guide Metal bowl Metal bowl with level gauge
B B B B B
ACG20D 105 — 91 87 —
ACG30D 156 123 122 128 148
ACG40D 186 155 154 160 180
Note) For the accessory/optional specifications (with auto drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level
gauge), the total length (B dimension) will vary.

406
RoHS-ACG.qxd 10.7.26 6:02 PM Page 1

Series ACG
Air Combination
Attachments
Check Valve (K): 1/8, 1/4, 3/8 RoHS
A check valve with intermediate air release port can be easily A
installed to prevent a back flow of lubricant when redirecting the
air flow and releasing the air on the outlet side of the regulator.

B
Check valve

Bypass port size for


redirecting air flow
E
JIS Symbol

IN C OUT
D
Specifications
Model Effective area (mm2)
AKM2000 28
AKM3000 55
Bypass A B C D E Applicable model
AKM4000 Model
111 port size
Be sure to use above check valves when redirecting the air flow AKM2000 1/8, 1/4 40 40 28 11 11 ACG20/ACG20A
on the inlet side of the lubricator. Threads for IN and OUT ports
are not machined. AKM3000 1/8, 1/4 53 48 34 14 13 ACG30/ACG30A
AKM4000 1/4, 3/8 70 54 42 18 15 ACG40/ACG40A
How to Order ∗ Refer to the Standard Specifications and Attachment on page 396 or 399 for the
standard bypass port size when the check valve is used with ACG.

AKM 30 00 01
Check valve Bypass port size for
redirecting air flow
Body size Body size
Port
Symbol
20 30 40 size 20 30 40
01 1/8 쎲 쎲 —
02 1/4 쎲 쎲 쎲
03 3/8 — — 쎲

Thread type AC
Nil Rc
N NPT AF쏔
F G
AR
AL
AW쏔
A쏔G
AV
AF800
AF900

407
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 408

Series ACG

Pressure Switch (S)


A compact integrated pressure switch can be easily installed and

Approx. 500
facilitates the pressure detection of the line.
15 23

Pressure switch

C
B
JIS Symbol

Center of
F.R.L. body
A D

Specifications
Fluid Air Model A B C D Applicable model
Proof pressure 1.0 MPa IS1000M-20 11 76 66 28 ACG20/ACG20B/ACG20C
Maximum operating pressure 0.7 MPa IS1000M-30 13 86 72 30 ACG30/ACG30B/ACG30C
Regulating pressure range (when off) 0.1 to 0.4 MPa IS1000M-40 15 95 77 36 ACG40/ACG40B/ACG40C
Differential 0.08 MPa Note 1) Separate spacers are required for modular unit.
Note 2) Pressure switch cannot be mounted on the inlet and outlet sides of an ARG
Ambient and fluid temperature –5 to 60°C (With no freezing)
with an upward facing handle (optional specification: -Y).

Switch Characteristics How to Order


Contact point configuration 1a
Maximum contact point capacity 2 VA(AC), 2 W(DC)
Operating voltage: AC, DC 100 V or less
12 V to 24 VAC, DC : 50 mA
IS1000M 30
Maximum operating current 48 VAC, DC : 40 mA Pressure switch
100 VAC, DC : 20 mA
Body size
20 For ACG20
30 For ACG30
40 For ACG40

Accessory
Description
Symbol
Lead wire length Set pressure range Pressure unit
Nil 0.5 m 0.1 to 0.4 MPa MPa
P Note) 0.5 m 0.1 to 0.4 MPa MPa/psi dual scale
X202 0.5 m 0.1 to 0.6 MPa MPa
X202-PNote) 0.5 m 0.1 to 0.6 MPa MPa/psi dual scale
X201 3 m 0.1 to 0.4 MPa MPa
X201-PNote) 3 m 0.1 to 0.4 MPa MPa/psi dual scale
X215 3 m 0.1 to 0.6 MPa MPa
X215-PNote) 3 m 0.1 to 0.6 MPa MPa/psi dual scale
Note) This product is for overseas use only according to the new
Measurement Law. (The SI unit type is provided for use in Japan.)

408
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 409

Air Combination Series ACG

Pressure Relief 3 Port Valve (V)


With the use of a 3 port valve for residual pressure release,
pressure left in the line can be easily exhausted.

0
ø1
øH

x
3 port valve for

2
residual pressure release

D
E
F
JIS Symbol
(A)
2 G Lockable at the time of exhaust
A
AA
1 3
(P) (R)
Specifications
Port size Effective area (mm2) ( ): Effective Area mm2 (Cv)
Model
IN,OUT EXH. IN OUT OUT EXH.
SUP
1/8 10 (0.54) 11 (0.60)
VHS20 1/8
1/4 14 (0.76) 16 (0.87)

B
1/4 16 (0.87) 14 (0.76)
VHS30 1/4 IN OUT
3/8 31 (1.68) 29 (1.57)
1/4 27 (1.46) 36 (1.95)

C
VHS40 3/8 3/8 38 (2.06) 40 (2.17)
1/2 55 (2.98) 42 (2.28)
Note) Use an air filter on the IN side for operating protection. EXH.

How to Order (mm)

Model A AA B C D E F G H
VHS 30 03 VHS20 40 34 59 20 45 33 28 — 45
VHS30 53 46 78 29 55 42 30 — 55
Pressure relief
VHS40 70 63 107 39 58 44 36 22 63
3 port valve
Caution
Body size
1. If a tube, a stop valve or a silencer is connected to the exhaust
Symbol Applicable model port of VHS20/30, the effective sectional area should be larger
20 ACG20 than the figure indicated in the following table, to prevent
30 ACG30 malfunction caused by back pressure. (This is not applicable to
40 ACG40 VHS40)
Model Effective area (mm2)
Thread type VHS20 5
Nil Rc VHS30 5
N NPT
F G
Option AC
Code Description
Port size R Flow direction: Right to left AF
Body size Z (1) Name plate in imperial units (psi, °F)
Symbol Port
size 20 30 40 Note 1) Only for the NPT thread. AR
01 1/8  — — This product is for overseas use only
according to the new Measurement Law.
02 1/4    (The SI unit type is provided for use in Japan.) AL
03 3/8 —  
04 1/2 — — 
AW
AG
AV
AF800
AF900

409
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 410

Series ACG
Spacers and Brackets
Accessories
Spacer

D
Center of
F.R.L. body

C
1
X-X

B
RELEASE
X
Y200 Y400 2

X
Model A B C D Applicable model
Seal
Y200 3 35.5 18.5 48 ACG20
Y300 4 47 26 59 ACG30
Y400 5 57 31 65 ACG40
A
Spacer width
Replacement Parts
Part no.
Description Material
Y200 Y300 Y400
Seal HNBR Y200P-061S Y300P-060S Y400P-060S

Spacer with Bracket


øG

Center of
F.R.L. body
C
E

BB (Y200T only)

1
EE (Y100T, Y200T only)

X-X
RELEASE

X
B

2
E

X
G

Seal

Y200T Y400T
F J
H K A
D Spacer width

Model A B BB C D E EE F G øG H J K Applicable model


Y200T 3 — 67 29 53 24 33 12 5.5 5.5 19 3.2 30 ACG20
Y300T 4 82 — 41 68 35 — 14 7 7 21 4 41 ACG30
Y400T 5 96 — 48 81.5 40 — 18 9 9 26 4 50 ACG40

Replacement Parts
Part no.
Description Material
Y200T Y300T Y400T
Seal HNBR Y200P-061S Y300P-060S Y400P-060S

410
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 411

Modular Type
Regulator with Built-in Pressure Gauge
Series ARG
Regulator with Built-in Pressure Model Port size Accessory
Gauge
Series ARG

ARG20 1/8, 1/4

ARG30 1/4, 3/8

ARG40 1/4, 3/8, 1/2

Pages 412 to 415 Bracket


Regulator with Built-in Pressure Set nut for changing
Gauge with Backflow Function the mounting angle
Series ARGK ARG20K 1/8, 1/4
of pressure gauges

ARG30K 1/4, 3/8

ARG40K 1/4, 3/8, 1/2

Pages 416 to 420

AC
AF
AR
AL
AW
AG
AV
AF800
AF900

411
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 412

Regulator with Built-in Pressure Gauge

Series ARG20/30/40
How to Order

ARG 20 01 G1
Body size Made to Order
Symbol Port size (Refer to pages 421 and 422 for details.)
20 1/8 Symbol Specification
30 3/8 Setting and pressure gauge
X406 full span 0.4 MPa
40 1/2
ARG20 Special pressure gauge mounting angle
X2101 (45°, 135°, 225°, 315°)
Thread type
Symbol Type
Nil Rc Option
N NPT Symbol Description
F G Nil —
Port size 1 (2) 0.02 to 0.2 MPa setting
N Non-relieving type
Port Body size (3) Name plate and pressure gauge in imperial
Symbol Z
size 20 30 40 units (psi)
01 1/8  — — ∗ When more than one specification is required,
indicate in ascending alphanumeric order.
ARG40 02 1/4   
Note 2) Adjusting spring and pressure gauge (full-
03 3/8 —   span 0.3 MPa) are different from those for
04 1/2 — —  the standard specification.
All products can be set at 0.2 MPa or more.
Note 3) For thread type NPT.
Accessory (1) This product is for overseas use only
according to the new Measurement Law.
Symbol Description (The SI unit type is provided for use in
Nil — Japan.)
B With bracket (With set nuts)
Accessory (2)
Symbol Description
Nil —
H With set nuts
Mounting Angle of Pressure Gauge
JIS Symbol
Symbol G1 G2 G3 G4
Mounting angle 0° 90° 180° 270°

MPa
Mounting angle IN OUT IN OUT IN OUT IN OUT

MPa
MPa

view P
MPa P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC

∗ Mounting angles other than 45°, 135°, 225° and 315° are available through the Made to Order (page 422).
∗ Possible to change to the optional mounting angles.
For details, refer to page 434, “Procedure for replacing or changing the mounting angle of a pressure gauge”.

: Combination available
: Combination not available
Accessory/Optional Combinations : Available only with NPT thread
Combination Applicable
Accessory Option regulator
Symbol
Accessory/Optional specifications B H 1 N Z ARG20 to 40
Accessory

With bracket B

With set nut H


0.02 to 0.2 MPa setting -1
Option

Non-relieving type -N
Name plate and pressure gauge in imperial units (psi) -Z

412
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 413

Regulator with Built-in Pressure Gauge Series ARG20/30/40

Standard Specifications
Model ARG20 ARG30 ARG40
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5° to 60°C (With no freezing)
Construction Relieving type
Mass (kg) 0.31 0.40 0.57

Accessory Part No.


Applicable model
ARG20 ARG30 ARG40
Accessory
Bracket assembly (1) ARG20P-270AS ARG30P-270AS ARG40P-270AS
Set nut ARG20P-260S ARG30P-260S ARG40P-260S
Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure
Pressure gauge 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
gauge display Optional 0 to 150 psi GB2-P10AS GB3-P10AS GB4-P10AS
range
0 to 45 psi GB2-P3AS GB3-P3AS GB4-P3AS
Note 1) Assembly includes a bracket and set nuts.

Flow Characteristics (Representative Values) Condition: Inlet pressure 0.7 MPa

ARG20 Rc1/4 ARG30 Rc3/8 ARG40 Rc1/2


0.6 0.6 0.6

0.5 0.5 0.5


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

0.4 0.4 0.4

0.3 0.3 0.3

0.2 0.2 0.2

0.1 0.1 0.1

0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa,


Pressure Characteristics (Representative Values) Flow rate 20 l/min (ANR)
AC
ARG20 ARG30 ARG40
0.25 0.25 0.25 AF
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

AR
Set point Set point Set point

0.2 0.2 0.2


AL
AW
AG
0.15 0.15 0.15
0 0 0
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Inlet pressure (MPa)
1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Inlet pressure (MPa)
1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Inlet pressure (MPa)
1 AV
AF800
AF900

413
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 414

Series ARG20/30/40

Construction
Specific Product
Precautions
A-A B-B
Be sure to read before handling.
Refer to front matters 42 and 43 y
for Safety Instructions and pages
287 to 291 for F.R.L. Precautions. r

IN OUT
Selection
q
Warning
1. Releasing the inlet pressure does not t
mean that all residual pressure is released
(the outlet pressure cannot be released).
When releasing residual pressure, use a
regulator with a backflow function.
w o
Mounting and Adjustment
Warning i e
1. Set the regulator while verifying the
displayed values of the inlet and outlet u
pressure gauges. Turning the regulator
handle excessively can cause damage to
the internal parts.
2. Do not use tools on the pressure regulator
handle as this may cause damage. It must
be operated manually.
B

Caution
1. Be sure to unlock the handle before
adjusting the pressure and lock it after
A A
setting the pressure.
Failure to follow this procedure can cause
damage to the handle and the outlet
pressure may fluctuate. P
• Pull the pressure regulator handle to US K
H to L OC
unlock. (You can visually verify this with
the “orange mark” that appears in the
gap.) B
• Push the pressure regulator handle to
lock. When the handle is not easily
locked, turn it left and right a little and
then push it (when the handle is locked,
the “orange mark”, i.e., the gap will
disappear).
Component Parts
Material
No. Description Note
ARG20 ARG30 ARG40
Orange mark 1 Body ZDC ADC Platinum silver
2 Bonnet PBT Black
3 Handle POM Black

Replacement Parts
Part no.
No. Description Material Qty.
2. When using the regulator between a ARG20 ARG30 ARG40
solenoid valve and an actuator, check the 4 Valve Brass, HNBR 1 AR20P-410S AR30P-410S AR40P-410S
pressure gauge periodically. 5 Diaphragm assembly Weatherability NBR 1 AR20P-150AS AR30P-150AS AR40P-150AS
6 Valve guide assembly POM, NBR 1 AR20P-050AS AR30P-050AS AR40P-050AS
7 Pressure gauge cover PC 1 ARG20P-400S ARG30P-400S ARG40P-400S
8 Pressure gauge — 1 GB2-10AS GB3-10AS GB4-10AS
9 Clip Stainless steel 1 ARG20P-420S ARG30P-420S ARG40P-420S
Note) Only the standard part numbers are listed in the pressure gauges. For the optional part numbers,
refer to page 413.
414
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 415

Regulator with Built-in Pressure Gauge Series ARG20/30/40

Dimensions

2xP
E F (Port size)
A D

C
IN OUT
SMC

H
R
B
S

Set nut
(Option)
T V
G

Q N
U
Bracket
(Option)

Panel fitting dimension


L
øK

IN OUT
øM

øJ P
U K
SH
to L O C

Plate thickness AC
ARG20 to 40: Max. 3.5
AF
AR
AL
AW

Standard specifications Accessory specifications


AG
Model Note) Panel mount Bracket mount
P A B C D E F G
H J K L M Q U T S R V N
AV
ARG20 1/8, 1/4 40 114 26.5 57 45 47 M39 x 1.5 38 52.5 39.5 19.5 6 48 65 10.4 5.4 60 2.3 35 AF800
ARG30 1/4, 3/8 53 138.5 31 59 58 59 M50 x 1.5 50 65 50.5 25 7 58.5 75 10.5 6.5 70 2.3 45 AF900
ARG40 1/4, 3/8, 1/2 70 150.5 36 68 70 70 M55 x 1.5 54 70 55.5 27.5 7 65.5 85 12.5 8.5 75 2.3 50
Note) Full length dimension B is measured when the handle is unlocked.
415
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 416

Regulator with Built-in Pressure Gauge


with Backflow Function

Series ARG20K/30K/40K
How to Order

ARG 20 K 01 G1
Made to Order
(Refer to pages 421 and 422 for details.)
Body size Symbol Specifications
Symbol Port size Setting and pressure gauge
X406 full span 0.4 MPa
20 1/8
ARG20K 30 3/8 Special pressure gauge mounting angle
X2101 (45°, 135°, 225°, 315°)
40 1/2

With backflow function Option


Symbol Description
Nil —
Thread type
1 (2) 0.02 to 0.2 MPa setting
Symbol Type
N Non-relieving type
Nil Rc
(3) Name plate and pressure gauge in imperial
N NPT Z units (psi)
F G ∗ When more than one specification is required,
indicate in ascending alphanumeric order.
ARG40K Note 2) Adjusting spring and pressure gauge (full-
Port size span 0.3 MPa) are different from those for
Body size the standard specification.
Port All products can be set at 0.2 MPa or
Symbol
size 20 30 40 more.
01 1/8  — — Note 3) For thread type NPT.
This product is for overseas use only
02 1/4    according to the new Measurement Law.
03 3/8 —   (The SI unit type is provided for use in
Japan.)
04 1/2 — — 

Accessory (1)
Accessory (2)
Symbol Description
Symbol Description
Nil —
Nil —
B With bracket (With set nuts)
H With set nuts

JIS Symbol Mounting Angle of Pressure Gauge


Symbol G1 G2 G3 G4
Mounting angle 0° 90° 180° 270°

MPa
Mounting angle IN OUT IN OUT IN OUT IN MPa OUT
MPa

view MPa
P P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC

∗ Mounting angles other than 45°, 135°, 225° and 315° are available through the Made to Order (page 422).
∗ Possible to change to the optional mounting angles.
For details, refer to page 434, “Procedure for replacing or changing the mounting angle of a pressure gauge”.

: Combination available
Accessory/Optional : Combination not available Application examples of a regulator
Combinations : Available only with NPT thread with a backflow function
Combination Applicable With a built-in mechanism which enables reliable
Accessory/ Accessory Option regulator
Optional Symbol discharge of air pressure from outlet to inlet
specifications B H 1 N Z ARG20 to 40
Example 1) Example 2)
Accessory

With bracket B When the pressure in the When the air supply is cut off and
rear and the front of the releasing the inlet pressure to the
cylinder differs: atmosphere, the residual pressure release
With set nut H of the outlet side can be ensured for a
Circuit diagram safety purpose.
0.02 to 0.2 MPa setting -1
Option

Non-relieving type -N Circuit diagram


Name plate and
pressure gauge in -Z
imperial units (psi)

416
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 417

Regulator with Built-in Pressure Gauge


with Backflow Function Series ARG20K/30K/40K

Standard Specifications
Model ARG20K ARG30K ARG40K
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range (1) 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5° to 60°C (With no freezing)
Construction Relieving type
Mass (kg) 0.31 0.40 0.57
Note 1) Set the inlet pressure to 0.05 MPa or higher than the set pressure.

Accessory Part No.


Applicable model
ARG20K ARG30K ARG40K
Accessory
Bracket assembly (1) ARG20P-270AS ARG30P-270AS ARG40P-270AS
Set nut ARG20P-260S ARG30P-260S ARG40P-260S
Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure
Pressure gauge 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
gauge display Optional 0 to 150 psi GB2-P10AS GB3-P10AS GB4-P10AS
range
0 to 45 psi GB2-P3AS GB3-P3AS GB4-P3AS
Note 1) Assembly includes a bracket and set nuts.

Flow Characteristics (Representative Values) Condition: Inlet pressure 0.7 MPa

ARG20K Rc1/4 ARG30K Rc3/8 ARG40K Rc1/2


0.6 0.6 0.6

0.5 0.5 0.5


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

0.4 0.4 0.4

0.3 0.3 0.3

0.2 0.2 0.2

0.1 0.1 0.1

0 0 0
0 200 400 600 800 0 500 1000 1500 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa,


Pressure Characteristics (Representative Values) Flow rate 20 l/min (ANR)
AC
ARG20K ARG30K ARG40K
0.25 0.25 0.25 AF
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

AR
Set point Set point Set point

0.2 0.2 0.2


AL
AW
AG
0.15 0.15 0.15
0 0 0
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Inlet pressure (MPa)
1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Inlet pressure (MPa)
1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Inlet pressure (MPa)
1
AV
AF800
AF900

417
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 418

Series ARG20K/30K/40K

Working Principle
Specific Product
A-A
A w Precautions
Be sure to read before handling.
Refer to front matters 42 and 43 for
Safety Instructions and pages 287
OUT

to 291 for F.R.L. Precautions.


1
IN

SMC Mounting and Adjustment


Warning
1. Set the regulator while verifying the
A displayed values of the inlet and outlet
pressure gauges. Turning the regulator
handle excessively can cause damage to
the internal parts.
2. Do not use tools on the pressure regulator
handle as this may cause damage. It must
be operated manually.
r

IN OUT Figure 1 Caution


(Inlet pressure) (Outlet pressure) w Normal 1. Be sure to unlock the handle before
adjusting the pressure and lock it after
q setting the pressure.
Failure to follow this procedure can cause
e Inlet pressure Pressure in
(IN) diaphragm chamber
damage to the handle and the outlet
pressure may fluctuate.
• Pull the pressure regulator handle to
unlock. (You can visually verify this with
Figure 3 the “orange mark” that appears in the
gap.)
Figure 2 • Push the pressure regulator handle to
Back flow lock. When the handle is not easily
locked, turn it left and right a little and
IN OUT then push it (when the handle is locked,
the “orange mark”, i.e., the gap will
(Inlet pressure) (Outlet pressure)
Inlet pressure Pressure in disappear).
(IN) diaphragm chamber

Orange mark

When the inlet pressure (P1) is higher than the regulating pressure, the check valve
w closes and operates as a normal regulator (Figure 1).
When the inlet pressure (P1) is shut off and released, the check valve w opens and
the pressure in the diaphragm chamber q is released into the inlet side (Figure 2).
This lowers the pressure in the diaphragm chamber q and the force generated by the
pressure regulator spring e lifts the diaphragm. Valve r opens through the stem, Maintenance
and the outlet pressure is released to the inlet side (Figure 3).
Warning
1. When using the regulator between a
solenoid valve and an actuator, check the
pressure gauge periodically.
Sudden pressure fluctuations may shorten
the durability of the pressure gauge.

418
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 419

Regulator with Built-in Pressure Gauge


with Backflow Function Series ARG20K/30K/40K

Construction

B-B
A-A
y

IN OUT

q
!0
t

i e o

A A

P
US K
H to L O C

Component Parts
No. Description
Material
Note AC
ARG20K ARG30K ARG40K
1 Body ZDC ADC Platinum silver AF
2 Bonnet PBT Black
3 Handle POM Black AR
Replacement Parts AL
Part no.
No. Description Material Qty.
ARG20K ARG30K ARG40K
AW
4 Valve Brass, HNBR 1 AR20P-410S AR30P-410S AR40P-410S
5 Diaphragm assembly Weatherability NBR 1 AR20P-150AS AR30P-150AS AR40P-150AS
AG
6 Valve guide assembly POM, NBR 1 AR20P-050AS AR30P-050AS AR40P-050AS
7 Pressure gauge cover PC 1 ARG20P-400S ARG30P-400S ARG40P-400S
AV
8 Pressure gauge (1) — 1 GB2-10AS GB3-10AS GB4-10AS
9 Clip Stainless steel 1 ARG20P-420S ARG30P-420S ARG40P-420S AF800
10 Check valve assembly (2) — 1 AR20KP-020AS
AF900
Note 1) Only the standard part numbers are listed for the pressure gauges. For the optional part numbers, refer to page 417.
Note 2) Check valve assembly contains check valve, check valve cover and its screws (2 pcs).
419
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 420

Series ARG20K/30K/40K

Construction

2xP
E F (Port size)
A D

C
IN OUT
SMC

H
R
B
S

Set nut
(Option)
T V
G

Q N
U
Bracket
(Option)

Panel fitting dimension


L
øK

IN OUT
øM

øJ
P
US K
H to L O C

Plate thickness
ARG20K to 40K: Max. 3.5

Standard specifications Accessory specifications


Model Note) Panel mount Bracket mount
P A B C D E F G
H J K L M Q U T S R V N
ARG20K 1/8, 1/4 40 114 26.5 57 45 47 M39 x 1.5 38 52.5 39.5 19.5 6 48 65 10.4 5.4 60 2.3 35
ARG30K 1/4, 3/8 53 138.5 31 59 58 59 M50 x 1.5 50 65 50.5 25 7 58.5 75 10.5 6.5 70 2.3 45
ARG40K 1/4, 3/8, 1/2 70 150.5 36 68 70 70 M55 x 1.5 54 70 55.5 27.5 7 65.5 85 12.5 8.5 75 2.3 50
Note) Full length dimension B is measured when the handle is unlocked.
420
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 421

Regulator with Built-in Pressure Gauge


ARG20/30/40
Made to Order Specifications:
Contact SMC for detailed dimensions, specifications, and lead times.

q Setting and Pressure Gauge Full Span 0.4 MPa

ARG 20 01 G1 X406
Option
Body size Symbol Description
Symbol Port size Nil —
20 1/8 N Non-relieving type
ARG20 30 3/8 Z (2) Name plate and pressure gauge in imperial units (psi)
40 1/2 ∗ When more than one specification is required,
indicate in ascending alphanumeric order.
Note 2) For thread type NPT.
This product is for overseas use only
according to the new Measurement
Thread type Law. (The SI unit type is provided for
Symbol Type use in Japan.)
Nil Rc
N NPT
F G
Accessory (2)
Symbol Description
Port size
Nil —
ARG40 Port Body size
Symbol H With set nuts
size 20 30 40
01 1/8  — —
02 1/4   
Accessory (1)
03 3/8 —  
Symbol Description
04 1/2 — — 
Nil —
B With bracket (With set nuts)
With back flow mechanism
Symbol Description
Nil —
K With back flow mechanism

Mounting Angle of Pressure Gauge


Symbol G1 G2 G3 G4
Mounting angle 0° 90° 180° 270°

MPa
IN OUT IN OUT IN OUT IN OUT
MPa
MPa

Mounting angle
view P
MPa P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC

∗ Mounting angles other than 45°, 135°, 225° and 315° are available through the Made to Order (page 422).
∗ Possible to change to the optional mounting angles.
For details, refer to page 434, “Procedure for replacing or changing the mounting angle of a pressure gauge”.

Accessory/Optional Combinations : Combination available : Combination not available : Available only with NPT thread
Combination Applicable
Symbol
Accessory Option regulator AC
Accessory/Optional specifications B H N Z ARG20(K) to 40(K)
AF
Option Accessory

With bracket B

With set nut H AR


Non-relieving type -N
AL
Name plate and pressure gauge in imperial units (psi) -Z
AW
AG
AV
AF800
AF900

421
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 422

Regulator with Built-in Pressure Gauge


ARG20/30/40
Made to Order Specifications:
Contact SMC for detailed dimensions, specifications, and lead times.

wSpecial Mounting Angle Specification of Pressure Gauge (45°, 135°, 225°, 315°)

ARG 20 01 G5 X2101 A
Body size Mounting angle of
Symbol Port size
pressure gauge
20 1/8 Symbol Description
30 3/8 A 45°
40 1/2 B 135°
C 225°
D 315°
With back flow mechanism ∗ Refer to the table below.

Symbol Description
Nil —
K With back flow mechanism

Option
Thread type Symbol Description
Symbol Type Nil —
Nil Rc 1 (1) 0.02 to 0.2 MPa setting
N NPT N Non-relieving type
F G (2) Name plate and pressure gauge in
Z imperial units (psi)
∗ When more than one specification is
required, indicate in ascending
Port size alphanumeric order.
Port Body size Accessory (2) Note 1) Adjusting spring and pressure gauge
Symbol (full-span 0.3 MPa) are different from
size 20 30 40 Symbol Description
those for the standard specification.
01 1/8  — — Nil — All products can be set at 0.2 MPa or
H With set nuts more.
02 1/4    Note 2) For thread type NPT.
03 3/8 —   This product is for overseas use only
according to the new Measurement
04 1/2 — —  Special pressure gauge Law. (The SI unit type is provided for
mounting angle use in Japan.)

Accessory (1)
Symbol Description
Nil —
B With bracket (With set nuts)

Mounting Angle of Pressure Gauge


Symbol X2101A X2101B X2101C X2101D
Mounting angle 45° 135° 225° 315°
Name plate position Name plate position

45° 13 22 31
5° 5° 5°
MP

a
Mounting angle IN OUT IN OUT IN MP OUT IN OUT
a

MP
view
a

a
MP

P P P P
US K US K US K US K
C C C C
H to L O H to L O H to L O H to L O

Name plate position Name plate position

: Combination available
: Combination not available
Accessory/Optional Combinations : Available only with NPT thread
Combination Applicable
Accessory Option regulator
Symbol
Accessory/Optional specifications B H 1 N Z ARG20(K) to 40(K)
Accessory

With bracket B

With set nut H

0.02 to 0.2 MPa setting -1


Option

Non-relieving type -N
Name plate and pressure gauge in imperial units (psi) -Z
422
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 423

Modular Type
Filter Regulator with Built-in Pressure Gauge
Series AWG
Filter Regulator with Built-in Nominal
Pressure Gauge Model Port size filtration Accessory
rating
Series AWG

AWG20 1/8, 1/4

AWG30 1/4, 3/8

Bracket
AWG40 1/4, 3/8, 1/2
Float type auto drain
Pages 424 to 427
5 μm
Filter Regulator with Built-in Set nut for changing the
Pressure Gauge with Backflow mounting angle of
Function AWG20K 1/8, 1/4 pressure gauges
Series AWGK

AWG30K 1/4, 3/8

AWG40K 1/4, 3/8, 1/2

Pages 428 to 432

AC
AF
AR
AL
AW
AG
AV
AF800
AF900

423
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 424

Filter Regulator with Built-in Pressure Gauge

Series AWG20/30/40
How to Order

AWG 30 03 G1 AWG20 AWG40


Made to Order
(Refer to page 433 for details.)
Symbol Specifications
X406 Setting and pressure gauge full span 0.4 MPa
Option
Body size Symbol Description Applicable model
Symbol Port size Nil — —
20 1/8 1 (3) 0.02 to 0.2 MPa setting AWG20 to 40
30 3/8 2 Metal bowl AWG20 to 40
40 1/2 6 Nylon bowl AWG20 to 40
8 Metal bowl with level gauge AWG30, 40
C With bowl guard AWG20
Thread type J (4) With drain guide AWG20 to 40
Symbol Type N Non-relieving AWG20 to 40
Nil Rc W Drain cock with barb fitting: ø6 x ø4 nylon tubing AWG30, 40
(1)
N NPT Z (5) Name plate, caution plate for bowl, and pressure gauge in imperial units (psi, °F) AWG20 to 40
(2)
F G ∗ When more than one specification is required, indicate in ascending alphanumeric order.
Note 1) Drain guide: NPT 1/8 (AW20(K)), Note 3) Adjusting spring and pressure gauge (full-span 0.3 MPa) are different
NPT 1/4 (AW30(K) to AW60(K)); from those for the standard specification.
Auto drain port: With ø3/8" One- All products can be set at 0.2 MPa or more.
touch fitting (AW30(K) to Note 4) Without a valve function.
Note 5) For thread type NPT.
AW60(K))
This product is for overseas use only according to the new
Note 2) Drain guide: G 1/8 (AW20(K)),
Measurement Law. (The SI unit type is provided for use in Japan.)
G 1/4 (AW30(K) to AW60(K)) Accessory (2)
Symbol Description Applicable model
Nil — —
H With set nuts AWG20 to 40
Port size
Port Body size Accessory (1)
Symbol
size 20 30 40 Symbol Description Applicable model
01 1/8  — — Nil — —
02 1/4    B With bracket (With set nuts) AWG20 to 40
C Float type auto drain (Normally closed) AWG20 to 40
03 3/8 —  
D Float type auto drain (Normally open) AWG30, 40
04 1/2 — — 
When more than one specification is required, indicate in ascending alphanumeric order.

JIS Symbol
Mounting Angle of Pressure Gauge
Symbol G1 G2 G3 G4
Mounting angle 0° 90° 180° 270°

MPa
IN OUT IN OUT IN OUT IN OUT
MPa
MPa

Mounting angle
view P
MPa P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC

∗ Possible to change to the optional mounting angles.


For details, refer to page 434, “Procedure for replacing or changing the mounting angle of a previous gauge”.

: Combination available : Combination not available


Accessory/Optional Combinations : Varies depending on a model : Available only with NPT thread
Symbol

Combination Accessory Option Applicable filter regulator


Accessory/Optional specifications B C D H 1 2 6 8 C J N W Z AWG20 AWG30/40
With bracket B
Accessory

Float type auto drain (Normally closed) C


Float type auto drain (Normally open) D
With set nut H
0.02 to 0.2 MPa setting -1
Metal bowl -2
Nylon bowl -6
Metal bowl with level gauge -8
Option

With bowl guard -C


Drain guide -J
Non-relieving type -N
Drain cock with barb fitting -W
Name plate, caution plate for bowl, and
pressure gauge in imperial units (psi, °F) -Z

424
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 425

Filter Regulator with Built-in Pressure Gauge Series AWG20/30/40


Standard Specifications
Model AWG20 AWG30 AWG40
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 μm
Drain capacity (cm3) 8 25 45
Bowl material Polycarbonate
Bowl guard Optional Standard
Construction Relieving type
Mass (kg) 0.38 0.51 0.86

Accessory Part No.


Applicable model
AWG20 AWG30 AWG40
Accessory
Bracket assembly (1) ARG20P-270AS ARG30P-270AS ARG40P-270AS
Set nut ARG20P-260S ARG30P-260S ARG40P-260S
Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure
Pressure gauge 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
gauge display Optional 0 to 150 psi GB2-P10AS GB3-P10AS GB4-P10AS
range
0 to 45 psi GB2-P3AS GB3-P3AS GB4-P3AS
(2) Normally open — AD38 AD48
Float type auto drain
Normally closed AD27 AD37 AD47
Note 1) Assembly includes a bracket and set nuts.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD27) and 0.15 MPa (AD37/47). Contact SMC regarding the specifications for psi unit and °F.

Flow Characteristics (Representative Values) Condition: Inlet pressure 0.7 MPa

AWG20 Rc1/4 AWG30 Rc3/8 AWG40 Rc1/2


0.6 0.6 0.6

0.5 0.5 0.5


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

0.4 0.4 0.4

0.3 0.3 0.3

0.2 0.2 0.2

0.1 0.1 0.1

0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
AC
Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa,
Pressure Characteristics (Representative Values) Flow rate 20 l/min (ANR) AF
AWG20 AWG30 AWG40 AR
0.25 0.25 0.25
AL
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point


Set point
AW
0.2 0.2 0.2
AG
AV
0.15 0.15 0.15 AF800
0 0 0 AF900
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

425
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 426

Series AWG20/30/40

Construction
AWG20 B AWG30/40 D

P
US K P
A H to L OC
A C US
H to L O C
K
C

B D

C-C
!0 D-D
!0
A-A B-B o
o !1
e
e !1
w
w
y
y
q q
IN OUT
IN OUT

u
u
r
r
t t
i i

Component Parts Replacement Parts


Material Part no.
No. Description Note No. Description Material Qty.
AWG20 AWG30 AWG40 AWG20 AWG30 AWG40
1 Body ZDC ADC Platinum silver 4 Valve assembly Brass, HNBR 1 AW20P-340AS AW30P-340AS AW40P-340AS
2 Bonnet PBT Black 5 Filter element Non-woven fabric 1 AF20P-060S AF30P-060S AF40P-060S
3 Handle POM Black 6 Diaphragm assembly Weatherability NBR 1 AR20P-150AS AR30P-150AS AR40P-150AS
7 Bowl O-ring NBR 1 C2SFP-260S C3SFP-260S C4SFP-260S
8 Bowl assembly (1) PC 1 C2SF C3SF (2) C4SF (2)
9 Pressure gauge (3) — 1 GB2-10AS GB3-10AS GB4-10AS
10 Pressure gauge cover PC 1 ARG20P-400S ARG30P-400S ARG40P-400S
11 Clip Stainless steel 1 ARG20P-420S ARG30P-420S ARG40P-420S
Note 1) Including O-ring. Contact SMC regarding the bowl assembly supply for psi and °F unit
specifications.
Note 2) Bowl assembly for AWG30/40 includes a bowl guard (steel band material).
Note 3) Only the standard part numbers are listed in the pressure gauges. For the optional part
numbers, refer to page 425.

Specific Product Precautions


Be sure to read before handling.
Refer to front matters 42 and 43 for Safety Instructions and pages 287 to 291 for F.R.L. Precautions.

Selection Mounting and Adjustment

Warning Warning • Pull the pressure regulator handle to


1. Residual pressure release (outlet 1. Set the regulator while checking the unlock. (You can visually verify this
pressure release) is not completed by displayed values of the inlet and outlet with the “orange mark” that appears in
releasing inlet pressure. To release pressure gauges. Turning the handle the gap.)
residual pressure, use a filter regulator excessively can cause damage to the • Push the pressure regulator handle to
with a back flow mechanism. internal parts. lock. When the handle is not easily
2. Do not use tools on the pressure locked, turn it left and right a little and
regulator handle as this may cause then push it (when the handle is
damage. It must be operated manually. locked, the “orange mark” will disap-
Maintenance pear).
Caution Orange mark
Warning 1. Be sure to unlock the handle before
1. Replace the element every 2 years or adjusting the pressure and lock it after
when the pressure drop becomes 0.1 setting the pressure.
MPa, whichever comes first, to prevent Failure to follow this procedure can
damage to the element. cause damage to the handle and the
outlet pressure may fluctuate.
426
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 427

Filter Regulator with Built-in Pressure Gauge Series AWG20/30/40

Dimensions

AWG20 Q
øT F Bracket Panel fitting dimension
K J (Option) U
G

øT
P R
IN OUT

øV
N

C
M
Plate thickness

S
Set nut AWG20: Max. 3.5
IN OUT (Option)

B
2xP
(Port size)

O S S O

Drain Min. clearance


H

A for maintenance
D
E

AWG30/40
Q
øT F Bracket Panel fitting dimension
K J (Option)
G V

øU
P R
IN OUT

øW
N

C
M

Set nut
S

Plate thickness
(Option) AWG30/40: Max. 3.5
IN OUT
B

2xP
(Port size)

Drain Min. clearance D


H

A for maintenance
E

Applicable model AWG20 AWG30/40


Accessory/Optional
specifications With auto drain (N.C.) Metal bowl With drain guide With auto drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B

B
B
B

Dimensions N.O.: Black


AC
B

OS N.C.: Gray
1/8
O
S
ø10 One-touch 1/4 Barb fitting
M5 x 0.8
Width across flats 14 fitting
Width across flats 17
Applicable tubing: T0604
AF
Standard specifications Accessory specifications AR
Model Note) Bracket mount
P A B C D E F G H
J K M N P Q R AL
AWG20 1/8, 1/4 40 179 91 52 45 47 M39 x 1.5 40 35 48 65 5.4 10.4 65 2.3
AWG30 1/4, 3/8 53 223.5 108.5 59 58 59 M50 x 1.5 55 45 58.5 70 6.5 10.5 75 2.3 AW
AWG40 1/4, 3/8, 1/2 70 261.5 114.5 75 70 70 M55 x 1.5 80 50 65.5 77 8.5 12.5 85 2.3

Accessory specifications Optional specifications


AG
Model Panel mount With auto drain With barb fitting With drain guide Metal bowl Metal bowl with level gauge
S U V W T B B Note) B Note) B Note) B Note)
AV
AWG20 43 39.5 19.5 6 52.5 196 — 183 179 — AF800
AWG30 50 50.5 25 7 65 264.5 231.5 230.5 256.5 276.5 AF900
AWG40 56 55.5 27.5 7 70 300.5 269.5 268.5 274.5 294.5
Note) Full length dimension B is measured when the handle is unlocked.
427
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 428

Filter Regulator with Built-in Pressure Gauge


with Backflow Function

Series AWG20K/30K/40K
How to Order

AWG 30 K 03 G1 AWG20K AWG40K


Made to Order
(Refer to page 433 for details.)
Symbol Specifications
X406 Setting and pressure gauge full span 0.4 MPa
Option
Body size
Symbol Description Applicable model
Symbol Port size
20 1/8
Nil — —
1 (3) 0.02 to 0.2 MPa setting AWG20K to 40K
30 3/8
2 Metal bowl AWG20K to 40K
40 1/2
6 Nylon bowl AWG20K to 40K
With backflow 8 Metal bowl with level gauge AWG30K, 40K
function C With bowl guard AWG20K
J (4) With drain guide AWG20K to 40K
Thread type N Non-relieving AWG20K to 40K
Symbol Type W Drain cock with barb fitting: ø6 x ø4 nylon tubing AWG30K, 40K
Nil Rc Z (5) Name plate, caution plate for bowl, and pressure gauge in imperial units (psi, °F) AWG20K to 40K
N (1)
NPT ∗ When more than one specification is required, indicate in ascending alphanumeric order.
(2)
Note 3) Adjusting spring and pressure gauge (full-span 0.3 MPa) are
F G different from those for the standard specification.
Note 1) Drain guide: NPT 1/8 (AW20(K)), All products can be set at 0.2 MPa or more.
NPT 1/4 (AW30(K) to AW60(K)); Note 4) Without a valve function.
Auto drain port: With ø3/8" One- Note 5) For thread type NPT.
touch fitting (AW30(K) to AW60(K)) This product is for overseas use only according to the new
Measurement Law. (The SI unit type is provided for use in Japan.)
Note 2) Drain guide: G 1/8 (AW20(K)), G 1/4 Accessory (2)
(AW30(K) to AW60(K))
Symbol Description Applicable model
Nil — —
H With set nuts AWG20K to 40K

Accessory (1)
Port size Symbol Description Applicable model
Nil — —
Port Body size
Symbol B With bracket (With set nuts) AWG20K to 40K
size 20 30 40
C Float type auto drain (Normally closed) AWG20K to 40K
01 1/8  — — D Float type auto drain (Normally open) AWG30K, 40K
02 1/4    When more than one specification is required, indicate in ascending alphanumeric order.
03 3/8 —  
04 1/2 — —  Mounting Angle of Pressure Gauge
Symbol G1 G2 G3 G4
Mounting angle 0° 90° 180° 270°

JIS Symbol IN OUT IN OUT IN


MPa
OUT IN OUT
Mounting angle
MPa
MPa

view MPa
P P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC

∗ Possible to change to the optional mounting angles.


For details, refer to page 434, “Procedure for replacing or changing the mounting angle of a
pressure gauge”.
Accessory/ : Combination available : Combination not available
Optional Combinations : Varies depending on a model : Available only with NPT thread
Symbol

Combination Accessory Option Applicable filter regulator


Accessory/Optional
specifications B C D H 1 2 6 8 C J N W Z AWG20K AWG30K/40K
Application example of a With bracket B
Accessory

filter regulator with a Float type auto drain (N.C.) C


backflow function Float type auto drain (N.O.) D
When the air supply is cut off and releasing With set nut H
the inlet pressure to the atmosphere, the
residual pressure release of the outlet side 0.02 to 0.2 MPa setting -1
can be ensured for a safety purpose. Metal bowl -2
Nylon bowl -6
Metal bowl with level gauge -8
Option

With bowl guard -C


With drain guide -J
Filter regulator
with back flow Non-relieving type -N
mechanism Drain cock with barb fitting -W
Name plate, caution plate for
bowl, and pressure gauge in -Z
imperial units (psi, °F)

428
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 429

Filter Regulator with Built-in Pressure


Gauge with Backflow Function Series AWG20K/30K/40K
Standard Specifications
Model AWG20K AWG30K AWG40K
Port sizes 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range (1) 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 μm
Drain capacity (cm3) 8 25 45
Bowl material Polycarbonate
Bowl guard Optional Standard
Construction Relieving type
Mass (kg) 0.38 0.51 0.86
Note 1) Set the inlet pressure so it should be 0.05 MPa or higher than the set pressure.

Accessory Part No.


Applicable model
AWG20K AWG30K AWG40K
Accessory
Bracket assembly (1) ARG20P-270AS ARG30P-270AS ARG40P-270AS
Set nut ARG20P-260S ARG30P-260S ARG40P-260S
Standard 0 to 1.0 MPa GB2-10AS GB3-10AS GB4-10AS
Pressure
Pressure gauge 0 to 0.3 MPa GB2-3AS GB3-3AS GB4-3AS
gauge display Optional 0 to 150 psi GB2-P10AS GB3-P10AS GB4-P10AS
range
0 to 45 psi GB2-P3AS GB3-P3AS GB4-P3AS
(2) Normally open — AD38 AD48
Float type auto drain
Normally closed AD27 AD37 AD47
Note 1) Assembly includes a bracket and set nuts.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD27) and 0.15 MPa (AD37/47). Contact SMC regarding the specifications for psi unit and °F.

Flow Characteristics (Representative Values) Condition: Inlet pressure 0.7 MPa

AWG20K Rc1/4 AWG30K Rc3/8 AWG40K Rc1/2


0.6 0.6 0.6

0.5 0.5 0.5


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

0.4 0.4 0.4

0.3 0.3 0.3

0.2 0.2 0.2

0.1 0.1 0.1

0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
AC
Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa,
Pressure Characteristics (Representative Values) Flow rate 20 l/min (ANR) AF
AWG20K AWG30K AWG40K AR
0.25 0.25 0.25
AL
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point Set point


AW
0.2 0.2 0.2
AG
AV
0.15 0.15 0.15 AF800
0 0 0 AF900
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

429
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 430

Series AWG20K/30K/40K

Working Principle

A-A w

P
U K
SH C
to L O

Figure 1
A Normal

Figure 3

e
Pressure in Inlet
q diaphragm
chamber
pressure
(IN)

IN OUT IN OUT Figure 2


(Inlet (Outlet (Inlet (Outlet
pressure) pressure) pressure) pressure) Back flow

r
Pressure in Inlet
diaphragm pressure
chamber (IN)
When the inlet pressure (P1) is higher than the regulating pressure, the check valve w closes and operates as a
normal regulator (Figure 1).
When the inlet pressure (P1) is shut off and released, the check valve w opens and the pressure in the diaphragm
chamber q is released into the inlet side (Figure 2).
This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e
lifts the diaphragm. Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 3).

Specific Product Precautions


Be sure to read before handling.
Refer to front matters 42 and 43 for Safety Instructions and pages 287 to 291 for F.R.L. Precautions.

Maintenance Mounting and Adjustment


Warning Warning • Push the pressure regulator handle to
1. Replace the element every 2 years or 1. Set the regulator while checking the lock. When the handle is not easily
when the pressure drop becomes 0.1 displayed values of the inlet and outlet locked, turn it left and right a little and
MPa, whichever comes first, to prevent pressure gauges. Turning the handle then push it (when the handle is
damage to the element. excessively can cause damage to the locked, the “orange mark” will disap-
internal parts. pear).
2. Do not use tools on the pressure
regulator handle as this may cause
damage. It must be operated manually. Orange mark

Caution
1. Be sure to unlock the handle before
adjusting the pressure and lock it after
setting the pressure.
Failure to follow this procedure can
cause damage to the handle and the
outlet pressure may fluctuate.
• Pull the pressure regulator handle to
unlock. (You can visually verify this
with the “orange mark” that appears in
the gap.)

430
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 431

Filter Regulator with Built-in Pressure


Gauge with Backflow Function Series AWG20K/30K/40K

Construction
AWG20K AWG30K/40K
B D

P
US K C P C
A H to L O C A U
SH K
to L O C

B D

C-C D-D

A-A B-B
!0
!0 o !1
o !1 e
e w
w y
y q
q !2 !2
IN OUT IN OUT

u u
r r
t t
i i

Component Parts
Material
No. Description Note
AWG20K AWG30K AWG40K
1 Body ZDC ADC Platinum silver
2 Bonnet PBT Black
3 Handle POM Black AC
Replacement Parts AF
Part no.
No. Description Material Qty.
AWG20K AWG30K AWG40K AR
4 Valve assembly Brass, HNBR 1 AW20P-340AS AW30P-340AS AW40P-340AS
5 Filter element Non-woven fabric 1 AF20P-060S AF30P-060S AF40P-060S AL
6 Diaphragm assembly Weatherability NBR 1 AR20P-150AS AR30P-150AS AR40P-150AS
7 Bowl O-ring NBR 1 C2SFP-260S C3SFP-260S C4SFP-260S AW
8 Bowl assembly (1) PC 1 C2SF C3SF (2) C4SF (2)
9 Pressure gauge (3) — 1 GB2-10AS GB3-10AS GB4-10AS AG
10 Pressure gauge cover PC 1 ARG20P-400S ARG30P-400S ARG40P-400S
11 Clip Stainless steel 1 ARG20P-420S ARG30P-420S ARG40P-420S AV
12 Check valve assembly — 1 AR20KP-020AS
Note 1) Including O-ring. Contact SMC regarding the bowl assembly supply for psi and °F unit specifications.
AF800
Note 2) Bowl assembly (AWG30K/40K) includes a bowl guard (steel band material). AF900
Note 3) Only the standard part numbers are listed for the pressure gauges. For the optional part numbers, refer to page 429.

431
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 432

Series AWG20K/30K/40K

Dimensions

AWG20K Q Bracket
øT F (Option) Panel fitting dimension
K J U
G

øT
P R
IN OUT

øV
N

C
M
Plate thickness

S
Set nut AWG20K: Max. 3.5
IN OUT (Option)

B
2xP
(Port size)

O S
Drain
H
Min. clearance
A D
for maintenance
E

AWG30K/40K Q Bracket
øT F (Option) Panel fitting dimension
K J
G V

øU
P R
IN OUT

øW
N

C
M

Set nut Plate thickness


S

(Option) AWG30K/40K: Max. 3.5


IN OUT
B

2xP
(Port size)

Drain
Min. clearance
H

A for maintenance D
E

Applicable model AWG20K AWG30K/40K


Accessory/Optional
specifications With auto drain (N.C.) Metal bowl With drain guide With auto drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
B

B
B
B

Dimensions N.O.: Black


B

N.C.: Gray
OS
1/8
O
S
ø10 One-touch Width 1/4 Barb fitting
M5 x 0.8 fitting across flats 17 Applicable tubing: T0604
Width across flats 14

Standard specifications Accessory specifications


Model Note) Bracket mount
P A B C D E F G H
J K M N P Q R
AWG20K 1/8, 1/4 40 179 91 52 45 47 M39 x 1.5 40 35 48 65 5.4 10.4 65 2.3
AWG30K 1/4, 3/8 53 223.5 108.5 59 58 59 M50 x 1.5 55 45 58.5 70 6.5 10.5 75 2.3
AWG40K 1/4, 3/8, 1/2 70 261.5 114.5 75 70 70 M55 x 1.5 80 50 65.5 77 8.5 12.5 85 2.3

Accessory specifications Optiional specifications


Model Panel mount With auto drain With barb fitting With drain guide Metal bowl Metal bowl with level gauge
S U V W T B Note) B Note) B Note) B Note) B Note)
AWG20K 43 39.5 19.5 6 52.5 196 — 183 179 —
AWG30K 50 50.5 25 7 65 264.5 231.5 230.5 256.5 276.5
AWG40K 56 55.5 27.5 7 70 300.5 269.5 268.5 274.5 294.5
Note) Full length demension B is measured when the handle is unlocked.
432
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 433

Filter Regulator with Built-in Pressure Gauge


AWG20/30/40
Made to Order Specifications:
Contact SMC for detailed dimensions, specifications, and lead times.

q Setting and Pressure Gauge Full Span 0.4 MPa

AWG 30 03 G1 X406
Body size
Option
Symbol Port size
Symbol Description Applicable model
20 1/8
30 3/8
Nil — —
2 Metal bowl AWG20(K) to 40(K)
40 1/2
6 Nylon bowl AWG20(K) to 40(K)
8 Metal bowl with level gauge AWG30(K), 40(K)
With back flow mechanism C With bowl guard AWG20(K)
Symbol Description J (3) With drain guide AWG20(K) to 40(K)
Nil — N Non-relieving AWG20(K) to 40(K)
K With back flow mechanism W Drain cock with barb fitting: ø6 x ø4 nylon tubing AWG30(K), 40(K)
Z (4) Name plate, caution plate for bowl, and pressure gauge in imperial units (psi, °F) AWG20(K) to 40(K)
Thread type ∗ When more than one specification is required, indicate in ascending alphanumeric order.
Note 3) Without a valve function.
Symbol Type Note 4) For thread type NPT.
Nil Rc This product is for overseas use only according to the new
Measurement Law. (The SI unit type is provided for use in Japan.)
N NPT
F G Accessory (2)
Note 1) Drain guide: NPT 1/8 (AW20(K)), Symbol Description Applicable model
NPT 1/4 (AW30(K) to AW60(K)); Nil — —
Auto drain port: With ø3/8" One-
touch fitting (AW30(K) to H With set nuts AWG20(K) to 40(K)
AW60(K))
Note 2) Drain guide: G 1/8 (AW20(K)),
G 1/4 (AW30(K) to AW60(K))
Accessory (1)
Symbol Description Applicable model
Nil — —
Port size B With bracket (With set nuts) AWG20(K) to 40(K)
Port Body size C Float type auto drain (Normally closed) AWG20(K) to 40(K)
Symbol
size 20 30 40 D Float type auto drain (Normally open) AWG30(K), 40(K)
01 1/8  — — When more than one specification is required, indicate in ascending
alphanumeric order.
02 1/4   
03 3/8 —  
04 1/2 — —  Mounting Angle of Pressure Gauge
Symbol G1 G2 G3 G4
Mounting angle 0° 90° 180° 270°

MPa
Mounting angle IN OUT IN OUT IN OUT IN OUT
MPa
MPa

view P
MPa P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC

∗ Possible to change to the optional mounting angles.


For details, refer to page 434, “Procedure for replacing or changing the mounting angle of a pressure
gauge”.

: Combination available : Combination not available


AC
Accessory/Optional Combinations : Varies depending on a model : Available only with NPT thread
Combination Accessory Option Applicable filter regulator
AF
Symbol
Accessory/Optional specifications B C D H 2 6 8 C J N W Z AWG20 AWG30/40
With bracket B AR
Accessory

Float type auto drain (Normally closed) C


Float type auto drain (Normally open) D AL
With set nut H
Metal bowl -2 AW
Nylon bowl -6
Metal bowl with level gauge -8 AG
Option

With bowl guard -C


Drain guide -J AV
Non-relieving type -N AF800
Drain cock with barb fitting -W AF900
Name plate, caution plate for bowl, and
pressure gauge in imperial units (psi, °F) -Z

433
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 434

Series ACG/ARG/AWG
Specific Product Precautions
Be sure to read before handling.
Refer to front matters 42 and 43 for Safety Instructions and pages 287 to 291 for F.R.L.
Precautions.

Procedure for replacing or changing the mounting angle of a pressure gauge

Warning
When replacing a pressure gauge and/or changing the mounting angle, release the inlet and outlet pressure completely. It is danger-
ous to replace the pressure gauge or change the mounting angle while it is under pressure.

1. Advance preparation 5. Setting the pressure gauge


Keep the handle unlocked and completely loosened. The un- After the mounting angle is adjusted as required, hold the out-
locked condition of the handle can be visually confirmed by er edge of the pressure gauge dial and gently press down.
the “Orange line” shown near the bottom of the handle. For reference, the required clearance between the bottom of
the dial and the top of the pressure regulator guide is shown
in table 1.
Note 1) When the pressure gauge cannot be easily positioned,
slightly rotate it. (The cog from the planet gear of the
Orange mark pressure regulator guide may be caught vertically in the
cog from the sun gear
which is mounted and

X
integrated with the
pressure gauge)
Note 2) Position the pressure
2. Removing the handle gauge to the very bot-
To remove the handle, align the  mark on the handle and tom.
the mark on the bonnet and then pull the handle. Note 3) Attached to the tip of
the pressure gauge is
an O-ring with grease
applied to it. Please Table 1. Clearance
Orange mark use caution to prevent Dimensions
particles and/or dust
 mark from entering the pres- ARG20 ARG30 ARG40
sure gauge when it is AWG20 AWG30 AWG40
mark set. Otherwise, they X dimension
Bonnet may cause air leak- (reference 2.6 mm 3.3 mm 3.3 mm
value)
age.
3. Removing the clip
When the mark on the bonnet and the  mark on the pres- 6. Setting the clip
sure regulator guide are alligned, the clip can be seen from Insert the clip in the side of the bonnet when the  mark on
the side view of the bonnet. The clip can be picked and re- the pressure regulator guide and the mark on the bonnet
moved with tweezers. are aligned. When inserting and setting the clip, use an in-
∗ When adjusting the mark, turn the pressure regulator guide strument with a narrow tip, such as tweezers.
clockwise for adjustment. Note 1) The clip is slightly tapered towards its tip to prevent it from
being released. Set the clip by slightly opening its tip.
Pressure regulator Note 2) When the clip cannot easily be set, the cause may be as
guide follows:
 mark Clip
(1) The pressure regulator screw might have been in a lower
Bonnet position than then the current one. (The pressure regula-
side view
tor screw may reach a lower position if the pressing force
of the pressure regulator screw is excessively applied.
mark This occurs because there is a clearance between the
Bonnet pressure regulator nut and pressure spring, when the
pressure regulator screw is loosened completely.)
(2) The pressure gauge is not firmly set.
4. Removing the pressure gauge Countermeasures ..... Refer to 5 “Setting the pressure
Pull the pressure gauge out by holding the outer edge of the gauge”.
dial.
Pressure regulator
∗ Do not touch the internal mechanical portion (shown inside guide
the dotted box). Accuracy of the pressure gauge may be
adversely affected.  mark Clip
Bonnet
side view
Outer edge

mark

Internal mechanical Bonnet


portion
7. Setting the handle
Finished when the handle is set.

434

Potrebbero piacerti anche