Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
AC
When mounting
Equipment on an equipment
AF
at approximately
OUT
foot level AR
AL
Floor
AW
When mounting
on a panel AG
AV
SMC
AF800
AF900
Panel
391
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 392
Installation and removal of pressure gauge Mounting angle of pressure gauge is selectable
cover is possible with one-touch. (PAT.PEND.) depending on the piping direction
∗ Mounting angle can be changed as desired. For details, refer to “Procedure for
Easy to adjust limit indicator. replacing or changing the mounting angle of a pressure gauge” on page 434.
MPa
angle view MPa
P P
US K US K
H to L O C H to L O C
MPa
angle view
P P
US K US K
H to L O C H to L O C
Mounting at 90° (In the case of restricted in side direction) Mounting at 45° (In the case of considering the effectiveness of panel)
∗ Contact SMC separately, since it will be made to order. (Refer to page 422.)
Surface of panel
OUT Surface of panel
SMC
IN
66
Bottom of panel
Bottom of panel
45°
IN 1 IN 1 IN 1
IN
IN
IN
SM
SM
SM
C
C
1
1
SMC
SMC
SMC
2
O
O
U
392
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 393
Standard Combinations
Components
Regulator with Built-in Filter Regulator with
Combination Model Port size Air filter Pressure Gauge Built-in Pressure Gauge Lubricator Mist separator
AF ARG AWG AL AFM
P. 327 P. 411 P. 423 P. 357 P. 338
AF + ARG + AL P. 396
ACG20 1/8, 1/4 AF20 ARG20 AL20
AWG + AL P. 399
ACG20A 1/8, 1/4 AWG20 AL20
AF + ARG P. 401
ACG20B 1/8, 1/4 AF20 ARG20
393
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 394
Series ACG
How to Order
ACG 30 03 G1
Option
Symbol Description Applicable model
Body size Nil — —
Symbol Port size 1 (8) 0.02 to 0.2 MPa setting ACG20 to 40
20 1/8 2 Metal bowl ACG20 to 40
30 3/8 3 Lubricator with drain cock ACG20 to 40
40 1/2 6 Nylon bowl ACG20 to 40
8 Metal bowl with level gauge ACG30, 40
C With bowl guard ACG20
Model combination
Combination J (9) Filter case with drain guide ACG20 to 40
Nil Rc Nil
N (3)
NPT AF + ARG + [K] + AL ACG20: 1/8
ACG20 to 40
Check
K valve ACG30: 1/4
F(4) G AWG + [K] + AL ACG20A to 40A ACG40: 3/8
Note 3) Drain guide is NPT1/8 for ACG20 and NPT1/4 for
AF + ARG + [S] + AL ACG20 to 40
ACG30 and 40. Auto-drain port is provided with (7) Pressure
ø3.8" One-touch fitting (applicable to ACG30 and S switch
AF + [S] + ARG ACG20B to 40B
40).
AF + AFM + [S] + ARG ACG20C to 40C
Note 4) Drain guide is G1/8 for ACG20 and G1/4 for
ACG30 and 40. AF + ARG + AL + [V] ACG20 to 40
Residual
AWG + AL + [V] ACG20A to 40A
pressure
Port size V relief AF + ARG + [V] ACG20B to 40B
Port Body size 3 port AF + AFM + ARG + [V] ACG20C to 40C
Symbol size valve
20 30 40 AWG + AFM + [V] ACG20D to 40D
01 1/8 — — Note 6) When more than one attachment is required, order in
02 1/4 alphabetical order.
Note 7) Pressure switch cannot be mounted on the inlet and outlet
03 3/8 — sides of an ARG with an upward facing handle (optional
04 1/2 — — specification: -Y).
394
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 395
Accessory/Optional Combinations
: Combination available : Combination not available : Varies depending on a model : Available only with NPT thread
F.R.L. unit applicable model
Symbol
Combination
Accessory Option
Accessory/ ACG30 ACG30A ACG30B ACG30C ACG30D
ACG20 ACG20A ACG20B ACG20C ACG20D
Optional specifications C D 1 2 3 6 8 C J N RW Y Z ACG40 ACG40A ACG40B ACG40C ACG40D
Attachments
Check valve 1/8, 1/4, 3/8 Prevents back flow from lubricator. P. 407
Accessories AC
Refer to page 410 for spacers and brackets.
AF
AR
AL
AW
AG
AV
AF800
AF900
395
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 396
Air Combination
Series ACG20/30/40
JIS Symbol
(2)
Float type auto drain
Normally open — AD38 AD48
Spacer Y200 Y300 Y400
Attachment
396
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 397
0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
Pressure Characteristics Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa, Flow rate 20 l/min (ANR)
0 0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)
Piping Selection
Warning Caution
1. When mounting a check valve, make sure the arrow (IN side) 1. Mounting a 3 port valve for residual pressure release on the IN
points in the correct direction of air flow. side of the lubricator can cause lubricant to back flow. Take
measures to prevent lubricant from splashing by installing a
filter on the EXH port.
Selection 2. An F.R.L. unit shipped from the plant has its model number
Warning labeled. However, components that are combined together
during the distribution process do not have a label on them.
1. Float type auto drain
Operate under the following conditions to avoid malfunction. AC
Air Supply
<N.O. type>
AF
• Operating compressor: 0.75 kW (100 l/min (ANR)) or more.
When using 2 or more auto drains, multiply the value above
Caution
by the number of auto drains to find the capacity of the 1. Use an air filter with 5 μm or less filtration rating on the inlet AR
compressors you will need. side of the valve to avoid any damage to the seat caused by
dust when mounting a 3 port valve for residual pressure AL
For example, when using 2 auto drains, 1.5 kW (200 l/min
release on the inlet side.
(ANR)) of the compressor capacity is required.
• Operating pressure: 0.1 MPa or more. AW
<N.C. type>
• Operating pressure for AD27: 0.1 MPa or more. AG
• Operating pressure for AD37/47: 0.15 MPa or more.
2. Use a regulator or filter regulator with a back flow mechanism AV
when mounting a 3 port valve for residual pressure release on
the IN side to ensure the release of the residual pressure. AF800
AF900
Otherwise, residual pressure will not be fully released.
397
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 398
Series ACG20/30/40
Dimensions
ACG20 Standard ACG30/40 Standard
Downward facing handle Downward facing handle
A
P G
A E F øL
2x
P G
L
E F
xø
2
H1
IN OUT
C
H2 H1
SMC
IN OUT
2xL
H2
SMC
4xL
OUT
J
2xK M
B
B
4xK M
Port size
Port size
for maintenance
Drain N
Min. clearance
for maintenance
Min. clearance
Drain
D
D
Air filter Regulator Lubricator
øL
C
øL
2x
C
x
2
H1
H1
IN SMC
OUT IN SMC
OUT
4xL
H2
2xL
H2
J
OUT
OUT
B
4xK M 2xK M
B
Port size
Port size
O
S
for maintenance
Drain
Min. clearance
D
Drain
clearance
Min.
D
for
B
B
B
B
Dimensions
B
N.O.: Black
B
N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 x 0.8 Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604
Standard specifications
Model Port size Bracket mount
A B C D P
E F G H1 H2 J K L øL M
ACG20 1/8, 1/4 126 87 36 60 28.5 41.5 43 30 24 — (1) — (1) — (1) — (1) 5.5 3.2
ACG30 1/4, 3/8 167 115 41 80 30 55 57 41 35 35 — 14 7 7 4
ACG40 1/4, 3/8, 1/2 220 147 48 110 38 72.5 75 50 40 40 — 18 9 9 4
Accessory/Optional specifications
Model Upward facing handle (2) With auto drain (3) With barb fitting (3) With drain guide (3) Metal bowl (3) Metal bowl with level gauge (3)
C H2 J K L B B B B B
ACG20 87 24 33 12 5.5 105 — 91 87 —
ACG30 108.5 35 — 14 7 156 123 122 128 148
ACG40 114.5 40 — 18 9 186 155 154 160 180
Note 1) In the case of the ACG20’s standard specification (downward facing handle), the wall mounting is not possible using the lower side mounting hole on the spacer with a
bracket. Use the upper side mounting hole when wall mounting.
Note 2) In the case of the upward facing handle in the optional specification, the C dimension will change. Also, in the case of the ACG20, wall mounting is possible by using the
lower side mounting hole on the spacer with a bracket.
Note 3) For the accessory/optional specifications (with auto drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level gauge), the total length (B dimension) will vary.
398
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 399
Air Combination
Series ACG20A/30A/40A
JIS Symbol
(2)
Float type auto drain
Normally open — AD38 AD48
Spacer
Attachment
399
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 400
Series ACG20A/30A/40A
Dimensions
ACG20A N A
E P G
øL
H2 H1
IN SMC OUT
2xL
J
OUT
B
2xK
M
Port size
O S S O
for maintenance
Min. clearance
Drain
D
ACG30A/40A N A
E P G
C
øL
H1
IN SMC OUT
H2
L
OUT
M
B
K
Port size
for maintenance
Min. clearance
Drain
D
B
B
B
B
Dimensions
B
N.O.: Black
B
N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 x 0.8 Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604
Standard specifications
Model Port size Bracket mount
A B C D N P
E G H1 H2 J K L øL M
ACG20A 1/8, 1/4 83 87 91 60 2.5 26 41.5 30 24 24 33 12 5.5 5.5 3.2
ACG30A 1/4, 3/8 110 115 108.5 80 2.5 30 55 41 35 35 — 14 7 7 4
ACG40A 1/4, 3/8, 1/2 145 147 114.5 110 0 38 72.5 50 40 40 — 18 9 9 4
Note)
Accessory/Optional specifications
Model With auto drain With barb fitting With drain guide Metal bowl Metal bowl with level gauge
B B B B B
ACG20A 105 — 91 87 —
ACG30A 156 123 122 128 148
ACG40A 186 155 154 160 180
Note) For the accessory/optional specifications (with auto drain, with barb fitting, with drain guide, metal bowl, or with level gauge), the total length (B dimension) will vary.
400
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 401
Air Combination
Series ACG20B/30B/40B
JIS Symbol
(2)
Float type auto drain
Normally open — AD38 AD48
Attachment
AF
AR
AL
AW
AG
AV
AF800
AF900
401
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 402
Series ACG20B/30B/40B
Dimensions
ACG20B Standard ACG30B/40B Standard
Downward facing handle Downward facing handle
A N
A N E P G
E P G øL
øL
H1
C
H2 H1
IN SMC
OUT IN OUT
SMC
2xL
H2
J
L
B
2xK M M
B
Port size K
Port size
o s
for maintenance
Drain
Min. clearance
D
for maintenance
Drain
Min. clearance
D
Air filter Regulator
øL
C
øL
C
H1
H2 H1
IN SMC
OUT IN SMC
OUT
2xL
H2
J
L
B
2xK M M
B
Port size K
Port size
O
o s S
for maintenance
Drain
Min. clearance
D
Drain
clearance
Min.
for
D
B
B
B
Dimensions
B
N.O.: Black
B
N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 x 0.8 Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604
Standard specifications
Model Port size Bracket mount
A B C D N P
E G H1 H2 J K L øL M
ACG20B 1/8, 1/4 83 87 29 60 2.5 28.5 41.5 30 — (1) — (1) — (1) — (1) — (1) — (1) 3.2
ACG30B 1/4, 3/8 110 115 41 80 2.5 29.5 55 41 35 35 — 14 7 7 4
ACG40B 1/4, 3/8, 1/2 145 147 48 110 0 38 72.5 50 40 40 — 18 9 9 4
Accessory/Optional specifications
Metal bowl with (3)
Model Upward facing handle (2) With auto drain (3)
With barb fitting (3) With drain guide (3) Metal bowl (3) level gauge
C H1 H2 J K L øL B B B B B
ACG20B 87 24 24 33 12 5.5 5.5 105 — 91 87 —
ACG30B 108.5 35 35 — 14 7 7 156 123 122 128 148
ACG40B 114.5 40 40 — 18 9 9 186 155 154 160 180
Note 1) In the case of the ACG20B’s standard specification (downward facing handle), the wall mounting is not possible using the lower side mounting hole on the spacer with a
bracket. Contact SMC.
Note 2) In the case of the upward facing handle in the optional specification, the C dimension will change. Also, in the case of the ACG20B, wall mounting is possible by using
the lower side mounting hole on the spacer with a bracket.
Note 3) For the accessory/optional specifications (with auto drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level gauge), the total length (B dimension) will vary.
402
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 403
Air Combination
Series ACG20C/30C/40C
JIS Symbol
(2)
Float type auto drain
Normally open — AD38 AD48
Attachment
403
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 404
Series ACG20C/30C/40C
Dimensions
ACG20C Standard ACG30C/40C Standard
Downward facing handle Downward facing handle
A N
E F ø L P G
A N 2x
E F øL P G
2x
H1
IN OUT
C
H2 H1
SMC
IN OUT
2xL
H2
SMC
4xL
J
2xK M
B
B
4xK M
Port size
Port size
o s o s
for maintenance
Drain Drain
Min. clearance
D
for maintenance
Drain Drain
Min. clearance
Air filter Mist separator Regulator
D Air filter Mist separator Regulator
2x
øL
C
2x
C
øL
H1
H2 H1
IN SMC
OUT IN SMC
OUT
4xL
2xL
H2
J
B
4xK M 2xK M
B
Port size
Port size
O
o s o s S
for maintenance
Drain Drain
Min. clearance
Drain Drain
clearance
Min.
for
D
B
B
B
B
B
N.C.: Gray
1/8
M5 x 0.8 ø10 One-touch 1/4 Barb fitting
Width across flats 17 fitting Width across flats 17 Applicable tubing: T0604
Standard specifications
Model Port size Bracket mount
A B C D N P
E F G H1 H2 J K L øL M
ACG20C 1/8, 1/4 126 87 29 60 2.5 28.5 41.5 43 30 24 — (1) — (1) — (1)
— (1) 5.5 3.2
ACG30C 1/4, 3/8 167 115 41 80 2.5 30 55 57 41 35 35 — 14 7 7 4
ACG40C 1/4, 3/8, 1/2 220 147 48 110 0 38 72.5 75 50 40 40 — 18 9 9 4
Accessory/Optional specifications
Model Upward facing handle (2) With auto drain (3)
With barb fitting (3) With drain guide (3) Metal bowl (3) Metal bowl with level gauge (3)
C H2 J K L B B B B B
ACG20C 87 24 33 12 5.5 105 — 91 87 —
ACG30C 108.5 35 — 14 7 156 123 122 128 148
ACG40C 114.5 40 — 18 9 186 155 154 160 180
Note 1) In the case of the ACG20C’s standard specification (downward facing handle), the wall mounting is not possible using the lower side mounting hole on the spacer with a
bracket. Use the upper side mounting hole when wall mounting.
Note 2) In the case of the upward facing handle in the optional specification, the C dimension will change. Also, in the case of the ACG20C, wall mounting is possible by using
the lower side mounting hole on the spacer with a bracket.
Note 3) For the accessory/optional specifications (with auto drain, with barb fitting, with drain guide, metal bowl, or metal bowl with level gauge), the total length (B dimension) will vary.
404
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 405
Air Combination
Series ACG20D/30D/40D
JIS Symbol
(2)
Float type auto drain
Normally open — AD38 AD48
Attachment
405
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 406
Series ACG20D/30D/40D
Dimensions
ACG20D N
E
A
P G
øL
C
H2 H1
IN SMC OUT
2xL
J
OUT
B
M
2xK
Port size
O
O S O S S
for maintenance
Min. clearance
Drain Drain
D
ACG30D/40D N A
E P G
C
øL
H1
IN SMC OUT
H2
L
OUT
M
B
K
Port size
for maintenance
Drain Drain
Min. clearance
D
B
B
B
B
B
Dimensions
B
N.O.: Black
B
N.C.: Gray
1/8
ø10 One-touch 1/4 Barb fitting
M5 x 0.8 Width across flats 17 fitting Applicable tubing: T0604
Width across flats 17
Standard specifications
Model Port size Bracket mount
A B C D N P
E G H1 H2 J K L øL M
ACG20D 1/8, 1/4 83 87 91 60 2.5 26 41.5 30 24 24 33 12 5.5 5.5 3.2
ACG30D 1/4, 3/8 110 115 108.5 80 2.5 30 55 41 35 35 — 14 7 7 4
ACG40D 1/4, 3/8, 1/2 145 147 114.5 110 0 38 72.5 50 40 40 — 18 9 9 4
406
RoHS-ACG.qxd 10.7.26 6:02 PM Page 1
Series ACG
Air Combination
Attachments
Check Valve (K): 1/8, 1/4, 3/8 RoHS
A check valve with intermediate air release port can be easily A
installed to prevent a back flow of lubricant when redirecting the
air flow and releasing the air on the outlet side of the regulator.
B
Check valve
IN C OUT
D
Specifications
Model Effective area (mm2)
AKM2000 28
AKM3000 55
Bypass A B C D E Applicable model
AKM4000 Model
111 port size
Be sure to use above check valves when redirecting the air flow AKM2000 1/8, 1/4 40 40 28 11 11 ACG20/ACG20A
on the inlet side of the lubricator. Threads for IN and OUT ports
are not machined. AKM3000 1/8, 1/4 53 48 34 14 13 ACG30/ACG30A
AKM4000 1/4, 3/8 70 54 42 18 15 ACG40/ACG40A
How to Order ∗ Refer to the Standard Specifications and Attachment on page 396 or 399 for the
standard bypass port size when the check valve is used with ACG.
AKM 30 00 01
Check valve Bypass port size for
redirecting air flow
Body size Body size
Port
Symbol
20 30 40 size 20 30 40
01 1/8 쎲 쎲 —
02 1/4 쎲 쎲 쎲
03 3/8 — — 쎲
Thread type AC
Nil Rc
N NPT AF쏔
F G
AR
AL
AW쏔
A쏔G
AV
AF800
AF900
407
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 408
Series ACG
Approx. 500
facilitates the pressure detection of the line.
15 23
Pressure switch
C
B
JIS Symbol
Center of
F.R.L. body
A D
Specifications
Fluid Air Model A B C D Applicable model
Proof pressure 1.0 MPa IS1000M-20 11 76 66 28 ACG20/ACG20B/ACG20C
Maximum operating pressure 0.7 MPa IS1000M-30 13 86 72 30 ACG30/ACG30B/ACG30C
Regulating pressure range (when off) 0.1 to 0.4 MPa IS1000M-40 15 95 77 36 ACG40/ACG40B/ACG40C
Differential 0.08 MPa Note 1) Separate spacers are required for modular unit.
Note 2) Pressure switch cannot be mounted on the inlet and outlet sides of an ARG
Ambient and fluid temperature –5 to 60°C (With no freezing)
with an upward facing handle (optional specification: -Y).
Accessory
Description
Symbol
Lead wire length Set pressure range Pressure unit
Nil 0.5 m 0.1 to 0.4 MPa MPa
P Note) 0.5 m 0.1 to 0.4 MPa MPa/psi dual scale
X202 0.5 m 0.1 to 0.6 MPa MPa
X202-PNote) 0.5 m 0.1 to 0.6 MPa MPa/psi dual scale
X201 3 m 0.1 to 0.4 MPa MPa
X201-PNote) 3 m 0.1 to 0.4 MPa MPa/psi dual scale
X215 3 m 0.1 to 0.6 MPa MPa
X215-PNote) 3 m 0.1 to 0.6 MPa MPa/psi dual scale
Note) This product is for overseas use only according to the new
Measurement Law. (The SI unit type is provided for use in Japan.)
408
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 409
0
ø1
øH
x
3 port valve for
2
residual pressure release
D
E
F
JIS Symbol
(A)
2 G Lockable at the time of exhaust
A
AA
1 3
(P) (R)
Specifications
Port size Effective area (mm2) ( ): Effective Area mm2 (Cv)
Model
IN,OUT EXH. IN OUT OUT EXH.
SUP
1/8 10 (0.54) 11 (0.60)
VHS20 1/8
1/4 14 (0.76) 16 (0.87)
B
1/4 16 (0.87) 14 (0.76)
VHS30 1/4 IN OUT
3/8 31 (1.68) 29 (1.57)
1/4 27 (1.46) 36 (1.95)
C
VHS40 3/8 3/8 38 (2.06) 40 (2.17)
1/2 55 (2.98) 42 (2.28)
Note) Use an air filter on the IN side for operating protection. EXH.
Model A AA B C D E F G H
VHS 30 03 VHS20 40 34 59 20 45 33 28 — 45
VHS30 53 46 78 29 55 42 30 — 55
Pressure relief
VHS40 70 63 107 39 58 44 36 22 63
3 port valve
Caution
Body size
1. If a tube, a stop valve or a silencer is connected to the exhaust
Symbol Applicable model port of VHS20/30, the effective sectional area should be larger
20 ACG20 than the figure indicated in the following table, to prevent
30 ACG30 malfunction caused by back pressure. (This is not applicable to
40 ACG40 VHS40)
Model Effective area (mm2)
Thread type VHS20 5
Nil Rc VHS30 5
N NPT
F G
Option AC
Code Description
Port size R Flow direction: Right to left AF
Body size Z (1) Name plate in imperial units (psi, °F)
Symbol Port
size 20 30 40 Note 1) Only for the NPT thread. AR
01 1/8 — — This product is for overseas use only
according to the new Measurement Law.
02 1/4 (The SI unit type is provided for use in Japan.) AL
03 3/8 —
04 1/2 — —
AW
AG
AV
AF800
AF900
409
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 410
Series ACG
Spacers and Brackets
Accessories
Spacer
D
Center of
F.R.L. body
C
1
X-X
B
RELEASE
X
Y200 Y400 2
X
Model A B C D Applicable model
Seal
Y200 3 35.5 18.5 48 ACG20
Y300 4 47 26 59 ACG30
Y400 5 57 31 65 ACG40
A
Spacer width
Replacement Parts
Part no.
Description Material
Y200 Y300 Y400
Seal HNBR Y200P-061S Y300P-060S Y400P-060S
Center of
F.R.L. body
C
E
BB (Y200T only)
1
EE (Y100T, Y200T only)
X-X
RELEASE
X
B
2
E
X
G
Seal
Y200T Y400T
F J
H K A
D Spacer width
Replacement Parts
Part no.
Description Material
Y200T Y300T Y400T
Seal HNBR Y200P-061S Y300P-060S Y400P-060S
410
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 411
Modular Type
Regulator with Built-in Pressure Gauge
Series ARG
Regulator with Built-in Pressure Model Port size Accessory
Gauge
Series ARG
AC
AF
AR
AL
AW
AG
AV
AF800
AF900
411
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 412
Series ARG20/30/40
How to Order
ARG 20 01 G1
Body size Made to Order
Symbol Port size (Refer to pages 421 and 422 for details.)
20 1/8 Symbol Specification
30 3/8 Setting and pressure gauge
X406 full span 0.4 MPa
40 1/2
ARG20 Special pressure gauge mounting angle
X2101 (45°, 135°, 225°, 315°)
Thread type
Symbol Type
Nil Rc Option
N NPT Symbol Description
F G Nil —
Port size 1 (2) 0.02 to 0.2 MPa setting
N Non-relieving type
Port Body size (3) Name plate and pressure gauge in imperial
Symbol Z
size 20 30 40 units (psi)
01 1/8 — — ∗ When more than one specification is required,
indicate in ascending alphanumeric order.
ARG40 02 1/4
Note 2) Adjusting spring and pressure gauge (full-
03 3/8 — span 0.3 MPa) are different from those for
04 1/2 — — the standard specification.
All products can be set at 0.2 MPa or more.
Note 3) For thread type NPT.
Accessory (1) This product is for overseas use only
according to the new Measurement Law.
Symbol Description (The SI unit type is provided for use in
Nil — Japan.)
B With bracket (With set nuts)
Accessory (2)
Symbol Description
Nil —
H With set nuts
Mounting Angle of Pressure Gauge
JIS Symbol
Symbol G1 G2 G3 G4
Mounting angle 0° 90° 180° 270°
MPa
Mounting angle IN OUT IN OUT IN OUT IN OUT
MPa
MPa
view P
MPa P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC
∗ Mounting angles other than 45°, 135°, 225° and 315° are available through the Made to Order (page 422).
∗ Possible to change to the optional mounting angles.
For details, refer to page 434, “Procedure for replacing or changing the mounting angle of a pressure gauge”.
: Combination available
: Combination not available
Accessory/Optional Combinations : Available only with NPT thread
Combination Applicable
Accessory Option regulator
Symbol
Accessory/Optional specifications B H 1 N Z ARG20 to 40
Accessory
With bracket B
Non-relieving type -N
Name plate and pressure gauge in imperial units (psi) -Z
412
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 413
Standard Specifications
Model ARG20 ARG30 ARG40
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5° to 60°C (With no freezing)
Construction Relieving type
Mass (kg) 0.31 0.40 0.57
0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
AR
Set point Set point Set point
413
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 414
Series ARG20/30/40
Construction
Specific Product
Precautions
A-A B-B
Be sure to read before handling.
Refer to front matters 42 and 43 y
for Safety Instructions and pages
287 to 291 for F.R.L. Precautions. r
IN OUT
Selection
q
Warning
1. Releasing the inlet pressure does not t
mean that all residual pressure is released
(the outlet pressure cannot be released).
When releasing residual pressure, use a
regulator with a backflow function.
w o
Mounting and Adjustment
Warning i e
1. Set the regulator while verifying the
displayed values of the inlet and outlet u
pressure gauges. Turning the regulator
handle excessively can cause damage to
the internal parts.
2. Do not use tools on the pressure regulator
handle as this may cause damage. It must
be operated manually.
B
Caution
1. Be sure to unlock the handle before
adjusting the pressure and lock it after
A A
setting the pressure.
Failure to follow this procedure can cause
damage to the handle and the outlet
pressure may fluctuate. P
• Pull the pressure regulator handle to US K
H to L OC
unlock. (You can visually verify this with
the “orange mark” that appears in the
gap.) B
• Push the pressure regulator handle to
lock. When the handle is not easily
locked, turn it left and right a little and
then push it (when the handle is locked,
the “orange mark”, i.e., the gap will
disappear).
Component Parts
Material
No. Description Note
ARG20 ARG30 ARG40
Orange mark 1 Body ZDC ADC Platinum silver
2 Bonnet PBT Black
3 Handle POM Black
Replacement Parts
Part no.
No. Description Material Qty.
2. When using the regulator between a ARG20 ARG30 ARG40
solenoid valve and an actuator, check the 4 Valve Brass, HNBR 1 AR20P-410S AR30P-410S AR40P-410S
pressure gauge periodically. 5 Diaphragm assembly Weatherability NBR 1 AR20P-150AS AR30P-150AS AR40P-150AS
6 Valve guide assembly POM, NBR 1 AR20P-050AS AR30P-050AS AR40P-050AS
7 Pressure gauge cover PC 1 ARG20P-400S ARG30P-400S ARG40P-400S
8 Pressure gauge — 1 GB2-10AS GB3-10AS GB4-10AS
9 Clip Stainless steel 1 ARG20P-420S ARG30P-420S ARG40P-420S
Note) Only the standard part numbers are listed in the pressure gauges. For the optional part numbers,
refer to page 413.
414
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 415
Dimensions
2xP
E F (Port size)
A D
C
IN OUT
SMC
H
R
B
S
Set nut
(Option)
T V
G
Q N
U
Bracket
(Option)
IN OUT
øM
øJ P
U K
SH
to L O C
Plate thickness AC
ARG20 to 40: Max. 3.5
AF
AR
AL
AW
Series ARG20K/30K/40K
How to Order
ARG 20 K 01 G1
Made to Order
(Refer to pages 421 and 422 for details.)
Body size Symbol Specifications
Symbol Port size Setting and pressure gauge
X406 full span 0.4 MPa
20 1/8
ARG20K 30 3/8 Special pressure gauge mounting angle
X2101 (45°, 135°, 225°, 315°)
40 1/2
Accessory (1)
Accessory (2)
Symbol Description
Symbol Description
Nil —
Nil —
B With bracket (With set nuts)
H With set nuts
MPa
Mounting angle IN OUT IN OUT IN OUT IN MPa OUT
MPa
view MPa
P P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC
∗ Mounting angles other than 45°, 135°, 225° and 315° are available through the Made to Order (page 422).
∗ Possible to change to the optional mounting angles.
For details, refer to page 434, “Procedure for replacing or changing the mounting angle of a pressure gauge”.
: Combination available
Accessory/Optional : Combination not available Application examples of a regulator
Combinations : Available only with NPT thread with a backflow function
Combination Applicable With a built-in mechanism which enables reliable
Accessory/ Accessory Option regulator
Optional Symbol discharge of air pressure from outlet to inlet
specifications B H 1 N Z ARG20 to 40
Example 1) Example 2)
Accessory
With bracket B When the pressure in the When the air supply is cut off and
rear and the front of the releasing the inlet pressure to the
cylinder differs: atmosphere, the residual pressure release
With set nut H of the outlet side can be ensured for a
Circuit diagram safety purpose.
0.02 to 0.2 MPa setting -1
Option
416
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 417
Standard Specifications
Model ARG20K ARG30K ARG40K
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Regulating pressure range (1) 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5° to 60°C (With no freezing)
Construction Relieving type
Mass (kg) 0.31 0.40 0.57
Note 1) Set the inlet pressure to 0.05 MPa or higher than the set pressure.
0 0 0
0 200 400 600 800 0 500 1000 1500 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
AR
Set point Set point Set point
417
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 418
Series ARG20K/30K/40K
Working Principle
Specific Product
A-A
A w Precautions
Be sure to read before handling.
Refer to front matters 42 and 43 for
Safety Instructions and pages 287
OUT
Orange mark
When the inlet pressure (P1) is higher than the regulating pressure, the check valve
w closes and operates as a normal regulator (Figure 1).
When the inlet pressure (P1) is shut off and released, the check valve w opens and
the pressure in the diaphragm chamber q is released into the inlet side (Figure 2).
This lowers the pressure in the diaphragm chamber q and the force generated by the
pressure regulator spring e lifts the diaphragm. Valve r opens through the stem, Maintenance
and the outlet pressure is released to the inlet side (Figure 3).
Warning
1. When using the regulator between a
solenoid valve and an actuator, check the
pressure gauge periodically.
Sudden pressure fluctuations may shorten
the durability of the pressure gauge.
418
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 419
Construction
B-B
A-A
y
IN OUT
q
!0
t
i e o
A A
P
US K
H to L O C
Component Parts
No. Description
Material
Note AC
ARG20K ARG30K ARG40K
1 Body ZDC ADC Platinum silver AF
2 Bonnet PBT Black
3 Handle POM Black AR
Replacement Parts AL
Part no.
No. Description Material Qty.
ARG20K ARG30K ARG40K
AW
4 Valve Brass, HNBR 1 AR20P-410S AR30P-410S AR40P-410S
5 Diaphragm assembly Weatherability NBR 1 AR20P-150AS AR30P-150AS AR40P-150AS
AG
6 Valve guide assembly POM, NBR 1 AR20P-050AS AR30P-050AS AR40P-050AS
7 Pressure gauge cover PC 1 ARG20P-400S ARG30P-400S ARG40P-400S
AV
8 Pressure gauge (1) — 1 GB2-10AS GB3-10AS GB4-10AS
9 Clip Stainless steel 1 ARG20P-420S ARG30P-420S ARG40P-420S AF800
10 Check valve assembly (2) — 1 AR20KP-020AS
AF900
Note 1) Only the standard part numbers are listed for the pressure gauges. For the optional part numbers, refer to page 417.
Note 2) Check valve assembly contains check valve, check valve cover and its screws (2 pcs).
419
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 420
Series ARG20K/30K/40K
Construction
2xP
E F (Port size)
A D
C
IN OUT
SMC
H
R
B
S
Set nut
(Option)
T V
G
Q N
U
Bracket
(Option)
IN OUT
øM
øJ
P
US K
H to L O C
Plate thickness
ARG20K to 40K: Max. 3.5
ARG 20 01 G1 X406
Option
Body size Symbol Description
Symbol Port size Nil —
20 1/8 N Non-relieving type
ARG20 30 3/8 Z (2) Name plate and pressure gauge in imperial units (psi)
40 1/2 ∗ When more than one specification is required,
indicate in ascending alphanumeric order.
Note 2) For thread type NPT.
This product is for overseas use only
according to the new Measurement
Thread type Law. (The SI unit type is provided for
Symbol Type use in Japan.)
Nil Rc
N NPT
F G
Accessory (2)
Symbol Description
Port size
Nil —
ARG40 Port Body size
Symbol H With set nuts
size 20 30 40
01 1/8 — —
02 1/4
Accessory (1)
03 3/8 —
Symbol Description
04 1/2 — —
Nil —
B With bracket (With set nuts)
With back flow mechanism
Symbol Description
Nil —
K With back flow mechanism
MPa
IN OUT IN OUT IN OUT IN OUT
MPa
MPa
Mounting angle
view P
MPa P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC
∗ Mounting angles other than 45°, 135°, 225° and 315° are available through the Made to Order (page 422).
∗ Possible to change to the optional mounting angles.
For details, refer to page 434, “Procedure for replacing or changing the mounting angle of a pressure gauge”.
Accessory/Optional Combinations : Combination available : Combination not available : Available only with NPT thread
Combination Applicable
Symbol
Accessory Option regulator AC
Accessory/Optional specifications B H N Z ARG20(K) to 40(K)
AF
Option Accessory
With bracket B
421
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 422
wSpecial Mounting Angle Specification of Pressure Gauge (45°, 135°, 225°, 315°)
ARG 20 01 G5 X2101 A
Body size Mounting angle of
Symbol Port size
pressure gauge
20 1/8 Symbol Description
30 3/8 A 45°
40 1/2 B 135°
C 225°
D 315°
With back flow mechanism ∗ Refer to the table below.
Symbol Description
Nil —
K With back flow mechanism
Option
Thread type Symbol Description
Symbol Type Nil —
Nil Rc 1 (1) 0.02 to 0.2 MPa setting
N NPT N Non-relieving type
F G (2) Name plate and pressure gauge in
Z imperial units (psi)
∗ When more than one specification is
required, indicate in ascending
Port size alphanumeric order.
Port Body size Accessory (2) Note 1) Adjusting spring and pressure gauge
Symbol (full-span 0.3 MPa) are different from
size 20 30 40 Symbol Description
those for the standard specification.
01 1/8 — — Nil — All products can be set at 0.2 MPa or
H With set nuts more.
02 1/4 Note 2) For thread type NPT.
03 3/8 — This product is for overseas use only
according to the new Measurement
04 1/2 — — Special pressure gauge Law. (The SI unit type is provided for
mounting angle use in Japan.)
Accessory (1)
Symbol Description
Nil —
B With bracket (With set nuts)
45° 13 22 31
5° 5° 5°
MP
a
Mounting angle IN OUT IN OUT IN MP OUT IN OUT
a
MP
view
a
a
MP
P P P P
US K US K US K US K
C C C C
H to L O H to L O H to L O H to L O
: Combination available
: Combination not available
Accessory/Optional Combinations : Available only with NPT thread
Combination Applicable
Accessory Option regulator
Symbol
Accessory/Optional specifications B H 1 N Z ARG20(K) to 40(K)
Accessory
With bracket B
Non-relieving type -N
Name plate and pressure gauge in imperial units (psi) -Z
422
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 423
Modular Type
Filter Regulator with Built-in Pressure Gauge
Series AWG
Filter Regulator with Built-in Nominal
Pressure Gauge Model Port size filtration Accessory
rating
Series AWG
Bracket
AWG40 1/4, 3/8, 1/2
Float type auto drain
Pages 424 to 427
5 μm
Filter Regulator with Built-in Set nut for changing the
Pressure Gauge with Backflow mounting angle of
Function AWG20K 1/8, 1/4 pressure gauges
Series AWGK
AC
AF
AR
AL
AW
AG
AV
AF800
AF900
423
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 424
Series AWG20/30/40
How to Order
JIS Symbol
Mounting Angle of Pressure Gauge
Symbol G1 G2 G3 G4
Mounting angle 0° 90° 180° 270°
MPa
IN OUT IN OUT IN OUT IN OUT
MPa
MPa
Mounting angle
view P
MPa P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC
424
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 425
0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
AC
Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa,
Pressure Characteristics (Representative Values) Flow rate 20 l/min (ANR) AF
AWG20 AWG30 AWG40 AR
0.25 0.25 0.25
AL
Outlet pressure (MPa)
425
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 426
Series AWG20/30/40
Construction
AWG20 B AWG30/40 D
P
US K P
A H to L OC
A C US
H to L O C
K
C
B D
C-C
!0 D-D
!0
A-A B-B o
o !1
e
e !1
w
w
y
y
q q
IN OUT
IN OUT
u
u
r
r
t t
i i
Dimensions
AWG20 Q
øT F Bracket Panel fitting dimension
K J (Option) U
G
øT
P R
IN OUT
øV
N
C
M
Plate thickness
S
Set nut AWG20: Max. 3.5
IN OUT (Option)
B
2xP
(Port size)
O S S O
A for maintenance
D
E
AWG30/40
Q
øT F Bracket Panel fitting dimension
K J (Option)
G V
øU
P R
IN OUT
øW
N
C
M
Set nut
S
Plate thickness
(Option) AWG30/40: Max. 3.5
IN OUT
B
2xP
(Port size)
A for maintenance
E
B
B
B
B
B
OS N.C.: Gray
1/8
O
S
ø10 One-touch 1/4 Barb fitting
M5 x 0.8
Width across flats 14 fitting
Width across flats 17
Applicable tubing: T0604
AF
Standard specifications Accessory specifications AR
Model Note) Bracket mount
P A B C D E F G H
J K M N P Q R AL
AWG20 1/8, 1/4 40 179 91 52 45 47 M39 x 1.5 40 35 48 65 5.4 10.4 65 2.3
AWG30 1/4, 3/8 53 223.5 108.5 59 58 59 M50 x 1.5 55 45 58.5 70 6.5 10.5 75 2.3 AW
AWG40 1/4, 3/8, 1/2 70 261.5 114.5 75 70 70 M55 x 1.5 80 50 65.5 77 8.5 12.5 85 2.3
Series AWG20K/30K/40K
How to Order
Accessory (1)
Port size Symbol Description Applicable model
Nil — —
Port Body size
Symbol B With bracket (With set nuts) AWG20K to 40K
size 20 30 40
C Float type auto drain (Normally closed) AWG20K to 40K
01 1/8 — — D Float type auto drain (Normally open) AWG30K, 40K
02 1/4 When more than one specification is required, indicate in ascending alphanumeric order.
03 3/8 —
04 1/2 — — Mounting Angle of Pressure Gauge
Symbol G1 G2 G3 G4
Mounting angle 0° 90° 180° 270°
view MPa
P P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC
428
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 429
0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
AC
Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa,
Pressure Characteristics (Representative Values) Flow rate 20 l/min (ANR) AF
AWG20K AWG30K AWG40K AR
0.25 0.25 0.25
AL
Outlet pressure (MPa)
429
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 430
Series AWG20K/30K/40K
Working Principle
A-A w
P
U K
SH C
to L O
Figure 1
A Normal
Figure 3
e
Pressure in Inlet
q diaphragm
chamber
pressure
(IN)
r
Pressure in Inlet
diaphragm pressure
chamber (IN)
When the inlet pressure (P1) is higher than the regulating pressure, the check valve w closes and operates as a
normal regulator (Figure 1).
When the inlet pressure (P1) is shut off and released, the check valve w opens and the pressure in the diaphragm
chamber q is released into the inlet side (Figure 2).
This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e
lifts the diaphragm. Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 3).
Caution
1. Be sure to unlock the handle before
adjusting the pressure and lock it after
setting the pressure.
Failure to follow this procedure can
cause damage to the handle and the
outlet pressure may fluctuate.
• Pull the pressure regulator handle to
unlock. (You can visually verify this
with the “orange mark” that appears in
the gap.)
430
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 431
Construction
AWG20K AWG30K/40K
B D
P
US K C P C
A H to L O C A U
SH K
to L O C
B D
C-C D-D
A-A B-B
!0
!0 o !1
o !1 e
e w
w y
y q
q !2 !2
IN OUT IN OUT
u u
r r
t t
i i
Component Parts
Material
No. Description Note
AWG20K AWG30K AWG40K
1 Body ZDC ADC Platinum silver
2 Bonnet PBT Black
3 Handle POM Black AC
Replacement Parts AF
Part no.
No. Description Material Qty.
AWG20K AWG30K AWG40K AR
4 Valve assembly Brass, HNBR 1 AW20P-340AS AW30P-340AS AW40P-340AS
5 Filter element Non-woven fabric 1 AF20P-060S AF30P-060S AF40P-060S AL
6 Diaphragm assembly Weatherability NBR 1 AR20P-150AS AR30P-150AS AR40P-150AS
7 Bowl O-ring NBR 1 C2SFP-260S C3SFP-260S C4SFP-260S AW
8 Bowl assembly (1) PC 1 C2SF C3SF (2) C4SF (2)
9 Pressure gauge (3) — 1 GB2-10AS GB3-10AS GB4-10AS AG
10 Pressure gauge cover PC 1 ARG20P-400S ARG30P-400S ARG40P-400S
11 Clip Stainless steel 1 ARG20P-420S ARG30P-420S ARG40P-420S AV
12 Check valve assembly — 1 AR20KP-020AS
Note 1) Including O-ring. Contact SMC regarding the bowl assembly supply for psi and °F unit specifications.
AF800
Note 2) Bowl assembly (AWG30K/40K) includes a bowl guard (steel band material). AF900
Note 3) Only the standard part numbers are listed for the pressure gauges. For the optional part numbers, refer to page 429.
431
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 432
Series AWG20K/30K/40K
Dimensions
AWG20K Q Bracket
øT F (Option) Panel fitting dimension
K J U
G
øT
P R
IN OUT
øV
N
C
M
Plate thickness
S
Set nut AWG20K: Max. 3.5
IN OUT (Option)
B
2xP
(Port size)
O S
Drain
H
Min. clearance
A D
for maintenance
E
AWG30K/40K Q Bracket
øT F (Option) Panel fitting dimension
K J
G V
øU
P R
IN OUT
øW
N
C
M
2xP
(Port size)
Drain
Min. clearance
H
A for maintenance D
E
B
B
B
N.C.: Gray
OS
1/8
O
S
ø10 One-touch Width 1/4 Barb fitting
M5 x 0.8 fitting across flats 17 Applicable tubing: T0604
Width across flats 14
AWG 30 03 G1 X406
Body size
Option
Symbol Port size
Symbol Description Applicable model
20 1/8
30 3/8
Nil — —
2 Metal bowl AWG20(K) to 40(K)
40 1/2
6 Nylon bowl AWG20(K) to 40(K)
8 Metal bowl with level gauge AWG30(K), 40(K)
With back flow mechanism C With bowl guard AWG20(K)
Symbol Description J (3) With drain guide AWG20(K) to 40(K)
Nil — N Non-relieving AWG20(K) to 40(K)
K With back flow mechanism W Drain cock with barb fitting: ø6 x ø4 nylon tubing AWG30(K), 40(K)
Z (4) Name plate, caution plate for bowl, and pressure gauge in imperial units (psi, °F) AWG20(K) to 40(K)
Thread type ∗ When more than one specification is required, indicate in ascending alphanumeric order.
Note 3) Without a valve function.
Symbol Type Note 4) For thread type NPT.
Nil Rc This product is for overseas use only according to the new
Measurement Law. (The SI unit type is provided for use in Japan.)
N NPT
F G Accessory (2)
Note 1) Drain guide: NPT 1/8 (AW20(K)), Symbol Description Applicable model
NPT 1/4 (AW30(K) to AW60(K)); Nil — —
Auto drain port: With ø3/8" One-
touch fitting (AW30(K) to H With set nuts AWG20(K) to 40(K)
AW60(K))
Note 2) Drain guide: G 1/8 (AW20(K)),
G 1/4 (AW30(K) to AW60(K))
Accessory (1)
Symbol Description Applicable model
Nil — —
Port size B With bracket (With set nuts) AWG20(K) to 40(K)
Port Body size C Float type auto drain (Normally closed) AWG20(K) to 40(K)
Symbol
size 20 30 40 D Float type auto drain (Normally open) AWG30(K), 40(K)
01 1/8 — — When more than one specification is required, indicate in ascending
alphanumeric order.
02 1/4
03 3/8 —
04 1/2 — — Mounting Angle of Pressure Gauge
Symbol G1 G2 G3 G4
Mounting angle 0° 90° 180° 270°
MPa
Mounting angle IN OUT IN OUT IN OUT IN OUT
MPa
MPa
view P
MPa P P P
US K US K US K US K
H to L OC H to L OC H to L OC H to L OC
433
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 434
Series ACG/ARG/AWG
Specific Product Precautions
Be sure to read before handling.
Refer to front matters 42 and 43 for Safety Instructions and pages 287 to 291 for F.R.L.
Precautions.
Warning
When replacing a pressure gauge and/or changing the mounting angle, release the inlet and outlet pressure completely. It is danger-
ous to replace the pressure gauge or change the mounting angle while it is under pressure.
X
integrated with the
pressure gauge)
Note 2) Position the pressure
2. Removing the handle gauge to the very bot-
To remove the handle, align the mark on the handle and tom.
the mark on the bonnet and then pull the handle. Note 3) Attached to the tip of
the pressure gauge is
an O-ring with grease
applied to it. Please Table 1. Clearance
Orange mark use caution to prevent Dimensions
particles and/or dust
mark from entering the pres- ARG20 ARG30 ARG40
sure gauge when it is AWG20 AWG30 AWG40
mark set. Otherwise, they X dimension
Bonnet may cause air leak- (reference 2.6 mm 3.3 mm 3.3 mm
value)
age.
3. Removing the clip
When the mark on the bonnet and the mark on the pres- 6. Setting the clip
sure regulator guide are alligned, the clip can be seen from Insert the clip in the side of the bonnet when the mark on
the side view of the bonnet. The clip can be picked and re- the pressure regulator guide and the mark on the bonnet
moved with tweezers. are aligned. When inserting and setting the clip, use an in-
∗ When adjusting the mark, turn the pressure regulator guide strument with a narrow tip, such as tweezers.
clockwise for adjustment. Note 1) The clip is slightly tapered towards its tip to prevent it from
being released. Set the clip by slightly opening its tip.
Pressure regulator Note 2) When the clip cannot easily be set, the cause may be as
guide follows:
mark Clip
(1) The pressure regulator screw might have been in a lower
Bonnet position than then the current one. (The pressure regula-
side view
tor screw may reach a lower position if the pressing force
of the pressure regulator screw is excessively applied.
mark This occurs because there is a clearance between the
Bonnet pressure regulator nut and pressure spring, when the
pressure regulator screw is loosened completely.)
(2) The pressure gauge is not firmly set.
4. Removing the pressure gauge Countermeasures ..... Refer to 5 “Setting the pressure
Pull the pressure gauge out by holding the outer edge of the gauge”.
dial.
Pressure regulator
∗ Do not touch the internal mechanical portion (shown inside guide
the dotted box). Accuracy of the pressure gauge may be
adversely affected. mark Clip
Bonnet
side view
Outer edge
mark
434